Options
| ProLiant 6400R Unique Options |
Compaq Hot Plug Redundant System
Fan Option Kit
When upgrading earlier versions of the
Pentium III Xeon 500 MHz models (those shipped prior to and during Q1,00 and equipped with
a single, hot plug rear fan) to use Pentium III Xeon 550 MHz processors, you are required
to install the Hot Plug Redundant System Fan Kit (P/N 157984-B21) to ensure proper
operation of your system. Install the fan kit prior to or at the time of upgrading the
processors in order to protect your server from the demanding thermal environment created
by the increasing power of the newest processor technology. Failure to purchase and
install this option kit may void the warranty or potentially damage the server. In
addition to ensuring the proper operation of your server, installation of the kit provides
the added benefit of providing fan redundancy across all the major subsystem components (
I/O, memory, and CPUs) of your server. |
157984-B21 |
|
Compaq Hot Plug Redundant Power
Supply Option Kit (U.S.)
(The Compaq ProLiant 6400R ships
standard with one hot plug power supply in bay one. For redundancy, a purchase of one
Compaq Hot Plug Redundant Power Supply Option Kit (105739-xx1) is required and can be
installed in bay two.) |
105739-001 |
|
Compaq Hot Plug Redundant Power
Supply Option Kit (Australia)
(The Compaq ProLiant 6400R ships
standard with one hot plug power supply in bay one. For redundancy, a purchase of one
Compaq Hot Plug Redundant Power Supply Option Kit (105739-xx1) is required and can be
installed in bay two.) |
105739-011 |
|
Compaq Hot Plug Redundant Power
Supply Option Kit (Intl)
(The Compaq ProLiant 6400R ships
standard with one hot plug power supply in bay one. For redundancy, a purchase of one
Compaq Hot Plug Redundant Power Supply Option Kit (105739-xx1) is required and can be
installed in bay two.) |
105739-021 |
|
Compaq Hot Plug Redundant Power
Supply Option Kit (Japan)
(The Compaq ProLiant 6400R ships
standard with one hot plug power supply in bay one. For redundancy, a purchase of one
Compaq Hot Plug Redundant Power Supply Option Kit (105739-xx1) is required and can be
installed in bay two.) |
105739-291 |
|
Compaq Redundant Power Processor
Module Option Kit |
105738-B21 |
|
Compaq High Voltage PDU Right
Angled Cable Kit (IEC14) (For use
with Compaq High-Voltage PDUs, this is a 15-Amp power cord with a right angle connector on
the side that plugs into the ProLiant 6400R server. The right angle connection at the
server improves cable management at the rear of the server.) |
142257-005 |
|
|
| Processor |
Non-redundant power
processor module |
|
|
Pentium III Xeon 6/550 2-MB
Processor Option Kit
Note: This processor option kit (PN
155224-B21) supports the ProLiant 6400R and ProLiant 5500 servers. |
155224-B21 |
|
Pentium III Xeon 6/550 1-MB
Processor Option Kit
Note: This processor option kit (PN
155223-B21) supports the ProLiant 6400R and ProLiant 5500 servers. |
155223-B21 |
|
Pentium III Xeon 6/550 512K
Processor Option Kit
Note: This processor option kit (PN
155222-B21) supports the ProLiant 6400R and ProLiant 5500 servers |
155222-B21 |
|
Pentium III Xeon 6/500 2-MB
Processor Option Kit
Note: This processor option kit (PN
117812-B21) supports the ProLiant 6400R and ProLiant 5500 servers. |
117812-B21 |
|
Pentium III Xeon 6/500 1-MB
Processor Option Kit
Note: This processor option kit (PN
117811-B21) supports the ProLiant 6400R and ProLiant 5500 servers. |
117811-B21 |
|
Pentium III Xeon 6/500 512K
Processor Option Kit
Note: This processor option kit (PN
117810-B21) supports the ProLiant 6400R and ProLiant 5500 servers. |
117810-B21 |
|
Redundant power processor
module |
|
|
Pentium III Xeon 6/550 2-MB
Processor Option Kit |
154714-B21 |
|
Pentium III Xeon 6/550 1-MB
Processor Option Kit |
154713-B21 |
|
Pentium III Xeon 6/550 512K
Processor Option Kit |
154712-B21 |
|
Pentium III Xeon 6/500 2-MB
Processor Option Kit |
117649-B21 |
|
Pentium III Xeon 6/500 1-MB
Processor Option Kit |
117648-B21 |
|
Pentium III Xeon 6/500 512K
Processor Option Kit |
117647-B21 |
|
Note:
The increasing power of new high-performance processor technology requires increased
cooling efficiency for rack-mounted servers. The new Compaq Rack 9000 series (part numbers
120663-xx1 (42U), 120664-xx1 (36U), 120665-xx1 (22U)) provides enhanced airflow for
maximum cooling, allowing these racks to be fully loaded with servers using the latest
processors.
When installing a server with Pentium III Xeon processors running at speeds of 550 MHz or
greater in Compaq Rack 7000 series racks (part numbers 165753-xx1 (42U), and 163747-xx1
(22U)), the new processor technology requires the installation of Compaqs new High
Airflow Rack Door Insert, part number 327281-B21 (42U) or 157847-B21 (22U). |
|
Note:
The increasing power of new high-performance processor technology requires increased
cooling efficiency for rack-mounted servers. The new Compaq Rack 9000 series (part numbers
120663-xx1 (42U), 120664-xx1 (36U), 120665-xx1 (22U)) provides enhanced airflow for
maximum cooling, allowing these racks to be fully loaded with servers using the latest
processors.
When installing a server with Pentium III Xeon processors running at speeds of 550 MHz or
greater in Compaq Rack 7000 series racks (part numbers 165753-xx1 (42U), and 163747-xx1
(22U)), the new processor technology requires the installation of Compaqs new High
Airflow Rack Door Insert, part number 327281-B21 (42U) or 157847-B21 (22U). |
|
|
| Memory (DIMMs) |
50ns EDO |
|
|
1024-MB EDO Memory Expansion Kit
(4 x 256-MB buffered EDO DIMMs, 50ns) |
328583-B21 |
|
512-MB EDO Memory Expansion Kit
(4 x 128-MB buffered EDO DIMMs, 50ns) |
328582-B21 |
|
256-MB EDO Memory Expansion Kit
(4 x 64-MB buffered EDO DIMMs, 50ns) |
328581-B21 |
|
|
|
|
60ns EDO |
|
|
1024-MB EDO Memory Expansion Kit
(4 x 256-MB buffered EDO DIMMs, 60ns) |
241774-B21 |
|
512-MB EDO Memory Expansion Kit
(4 x 128-MB buffered EDO DIMMs, 60ns) |
241773-B21 |
|
|
|
| Hard Drives |
Wide Ultra3
SCSI Universal Hot Plug |
|
|
|
36.4-GB Wide Ultra3
SCSI 10,000 rpm Drive (1² ) |
176496-B22 |
|
|
18.2-GB Wide Ultra3
SCSI 10,000 rpm Drive (1² ) |
142673-B22 |
|
|
9.1-GB Wide Ultra3
SCSI 10,000 rpm Drive (1² ) |
142671-B22 |
|
|
18.2-GB Wide Ultra3
SCSI 15,000 rpm Drive (1² ) |
188122-B22 |
|
|
9.1-GB Wide Ultra3
SCSI 15,000 rpm Drive (1² ) |
188120-B22 |
|
Note:
In order to store data at Wide Ultra3 SCSI speeds (160MB/sec), customers need three
components:
Wide Ultra3 SCSI Adapter or Array Controller
Wide Ultra3 SCSI Hard Drives
Wide Ultra3 SCSI capable cable or server backplane
The ProLiant 6400R 500 MHz and 550 MHz Models are not configured with an Ultra3 SCSI
capable cable. Therefore, customers are encouraged to purchase and install the Internal
Ultra3 Cable Option Kit, HP (PN 166390-B21) when upgrading their server to use Wide Ultra3
SCSI Adapters, Array Controllers, and hard drives. |
|
|
Wide Ultra2
SCSI Universal Hot Plug |
|
|
|
18.2-GB Wide Ultra2
SCSI Drive (1² ) |
388144-B22 |
|
|
9.1-GB Wide Ultra2
SCSI Drive (1² ) |
123065-B22 |
|
|
|
| Storage Controllers |
Smart Array 431 Controller |
127695-B21 |
|
Smart Array 431 Controller
(Japan) |
127695-291 |
|
Smart Array 3200 Controller |
295643-B21 |
|
Smart Array 3200 Controller
(Japan) |
295643-291 |
|
Smart Array 4200 Controller |
295636-B21 |
|
Smart Array 4200 Controller
(Japan) |
295636-291 |
|
Smart Array 5302/32 Controller |
166207-B21 |
|
Smart Array 5302/32 Controller
(Japan) |
166207-291 |
|
Smart Array 5302/64 Controller |
124992-B21 |
|
Smart Array 5302/64 Controller
(Japan) |
124992-291 |
|
Smart Array 5304/128 Controller |
158939-B21 |
|
Smart Array 5304/128 Controller
(Japan) |
158939-291 |
|
Ultra3 Channel Expansion Module
for Smart Array 5300 Controller |
153507-B21 |
|
64-bit/66-MHz Dual Channel Wide
Ultra3 SCSI Adapter
(The 64-bit/66-MHz Dual Channel Wide
Ultra3 SCSI Adapter (129803-xx1) will default to Wide Ultra2 when not used with the Wide
Ultra3 hard drives.) |
129803-B21 |
|
64-bit/66-MHz Dual Channel Wide
Ultra3 SCSI Adapter (Japan)
(The 64-bit/66-MHz Dual Channel Wide
Ultra3 SCSI Adapter (129803-xx1) will default to Wide Ultra2 when not used with the Wide
Ultra3 hard drives.) |
129803-291 |
|
64-bit/66-MHz Single Channel Wide
Ultra3 SCSI Adapter
(The 64-bit/66-MHz Single Channel Wide
Ultra3 SCSI Adapter (154457-xx1) will default to Wide Ultra2 when not used with the Wide
Ultra3 hard drives.) |
154457-B21 |
|
64-bit/66-MHz Single Channel Wide
Ultra3 SCSI Adapter (Japan)
(The 64-bit/66-MHz Single Channel Wide
Ultra3 SCSI Adapter (154457-xx1) will default to Wide Ultra2 when not used with the Wide
Ultra3 hard drives.) |
154457-291 |
|
Note:
In order to store data at Wide Ultra3 SCSI speeds (160MB/sec), customers need three
components:
Wide Ultra3 SCSI Adapter or Array Controller
Wide Ultra3 SCSI Hard Drives
Wide Ultra3 SCSI capable cable or server backplane
The ProLiant 6400R 500 MHz and 550 MHz Models are not configured with an Ultra3 SCSI
capable cable. Therefore, customers are encouraged to purchase and install the Internal
Ultra3 Cable Option Kit, HP (PN 166390-B21) when upgrading their server to use Wide Ultra3
SCSI Adapters, Array Controllers, and hard drives. |
|
|
| Communications |
Compaq NC3123 Fast Ethernet NIC
PCI 10/100 WOL |
174830-B21 |
|
Compaq NC3122 Fast Ethernet NIC
PCI Dual 10/100 |
317450-B21 |
|
Compaq NC3131 Fast Ethernet NIC
64 PCI Dual Base 10/100 |
338456-B21 |
|
Compaq NC3132 Fast Ethernet
Module Dual 10/100 Upgrade Module for NC3131 |
338456-B22 |
|
Compaq NC6132 Gigabit Module 1000
SX Upgrade Module for NC3131 |
338456-B23 |
|
Compaq NC6133 Gigabit Module 1000
LX Upgrade Module for NC3131 |
338456-B24 |
|
Compaq NC3133 Fast Ethernet
Module 100 FX Upgrade Module for NC3131 |
338456-B25 |
|
Compaq NC6134 Gigabit NIC 64 PCI
1000 SX |
174818-B21 |
|
Compaq NC4621 Token Ring NIC PCI
4/16 WOL |
379956-B21 |
|
ServerNet PCI Adapter |
309833-B22 |
|
4M Cable |
309834-B23 |
|
30M Cable |
309834-B22 |
|
ServerNet II PCI Adapter Card Kit |
174736-B21 |
|
ServerNet II 12-Port Copper
Serial Switch Kit (US) |
174739-001 |
|
ServerNet II 12-Port Copper
Serial Switch Kit (Intl) |
174739-B31 |
|
ServerNet II 5-meter Copper
Serial Cable Kit |
174737-B21 |
|
ServerNet II 10-meter Copper
Serial Cable Kit |
174738-B22 |
|
|
| Redundant Options |
Compaq Hot Plug Redundant System
Fan Option Kit
When upgrading earlier versions of the
Pentium III Xeon 500 MHz models (those shipped prior to and during Q1,00 and equipped with
a single, hot plug rear fan) to use Pentium III Xeon 550 MHz processors, you are required
to install the Hot Plug Redundant System Fan Kit (P/N 157984-B21) to ensure proper
operation of your system. Install the fan kit prior to or at the time of upgrading the
processors in order to protect your server from the demanding thermal environment created
by the increasing power of the newest processor technology. Failure to purchase and
install this option kit may void the warranty or potentially damage the server. In
addition to ensuring the proper operation of your server, installation of the kit provides
the added benefit of providing fan redundancy across all the major subsystem components (
I/O, memory, and CPUs) of your server. |
157984-B21 |
|
Compaq Hot Plug Redundant Power
Supply Option Kit (U.S.)
(The Compaq ProLiant 6400R ships
standard with one hot plug power supply in bay one. For redundancy, a purchase of one
Compaq Hot Plug Redundant Power Supply Option Kit (105739-xx1) is required and can be
installed in bay two.) |
105739-001 |
|
Compaq Hot Plug Redundant Power
Supply Option Kit (Australia)
(The Compaq ProLiant 6400R ships
standard with one hot plug power supply in bay one. For redundancy, a purchase of one
Compaq Hot Plug Redundant Power Supply Option Kit (105739-xx1) is required and can be
installed in bay two.) |
105739-011 |
|
Compaq Hot Plug Redundant Power
Supply Option Kit (Intl)
(The Compaq ProLiant 6400R ships
standard with one hot plug power supply in bay one. For redundancy, a purchase of one
Compaq Hot Plug Redundant Power Supply Option Kit (105739-xx1) is required and can be
installed in bay two.) |
105739-021 |
|
Compaq Hot Plug Redundant Power
Supply Option Kit (Japan)
(The Compaq ProLiant 6400R ships
standard with one hot plug power supply in bay one. For redundancy, a purchase of one
Compaq Hot Plug Redundant Power Supply Option Kit (105739-xx1) is required and can be
installed in bay two.) |
105739-291 |
|
Compaq Redundant Power Processor
Module Option Kit |
105738-B21 |
|
|
|
| Management Options |
Compaq Remote Insight Lights-Out
Edition (NA, LA)
(The ProLiant 6400R 500 MHz and 550 MHz
Models do not currently support the Virtual Power Button feature of the Compaq Remote
Insight Lights-Out Edition board (157866-xx1.) Next generation ProLiant DL580 servers will
ship standard with the Virtual Power Button capability.) |
157866-001 |
|
Compaq Remote Insight Lights-Out
Edition (EURO)
(The ProLiant 6400R 500 MHz and 550 MHz
Models do not currently support the Virtual Power Button feature of the Compaq Remote
Insight Lights-Out Edition board (157866-xx1.) Next generation ProLiant DL580 servers will
ship standard with the Virtual Power Button capability.) |
157866-021 |
|
Compaq Remote Insight Lights-Out
Edition (APD, Japan)
(The ProLiant 6400R 500 MHz and 550 MHz
Models do not currently support the Virtual Power Button feature of the Compaq Remote
Insight Lights-Out Edition board (157866-xx1.) Next generation ProLiant DL580 servers will
ship standard with the Virtual Power Button capability.) |
157866-371 |
|
Compaq Remote Insight (PCI) LAN +
NA Modem |
294013-002 |
|
Compaq Remote Insight (PCI) LAN +
NA Modem (PAN EURO) |
294013-B32 |
|
Compaq Remote Insight Board (PCI)
LAN/Serial without modem |
294013-B24 |
|
Compaq Remote Insight Board (PCI)
LAN/Serial without modem (Japan) |
294013-294 |
|
Compaq Remote Insight Board (PCI)
LAN only |
294013-B25 |
|
Compaq Remote Insight Board (PCI)
LAN only (Japan) |
294013-295 |
|
|
|
| Monitors |
TFT5010 15²
Flat Panel Monitor (Opal) |
104741-xxx |
|
TFT5010 15²
Flat Panel Monitor (Carbon) |
154486-xxx |
|
TFT5005 15²
Flat Panel Monitor (Opal) |
201431-xxx |
|
TFT5005 15²
Flat Panel Monitor (Carbon) |
201430-xxx |
|
TFT5000R Flat Panel Monitor (NA) |
120207-001 |
|
TFT5000R Flat Panel Monitor
(Intl) |
120207-B31 |
|
TFT5000R Flat Panel Monitor
(Japan) |
120207-291 |
|
P710 Color Monitor |
210189-xxx |
|
V710 Color Monitor |
187895-xxx |
|
V500 Color Monitor |
325900-xxx |
|
S710 Color Monitor |
168636-xxx |
|
S510 Color Monitor |
152991-xxx |
|
|
|
| CRT Country Code Key |
NORTH AMERICA (NA)
/ LATIN AMERICA (LA) |
|
|
Dash # |
Description |
|
|
-001 |
NA Kit
with US Power Cord |
|
|
-002 |
Carbon
model with US Power Cord |
|
|
-003 |
Touch
Screen model with US Power Cord |
|
|
-004 |
NAFTA
model with US Power Cord (Made in Mexico) |
|
|
-005 |
NA Kit
with Powered Speakers |
|
|
-006 |
GSA model
with US Power Cord |
|
|
-007 |
NH MPR
model with US power cord (Made in Mexico) |
|
|
-B24 |
TCO model
without power cord (Digital Classic) |
|
|
-201 |
EH model
for Brazil (older Brazil models used -B29) |
|
|
-202 |
EH model
for Brazil Carbon (older Brazil models used -B29) |
|
|
-C91 |
EH model
for Mercosur countries |
|
|
-C92 |
EH model
for Mercosur countries Carbon |
|
|
-B29 |
EH /
ALADI model for Latin America |
|
|
Note: All NA/LA models above are NH |
|
EUROPE, MIDDLE
EAST AND AFRICA (EMEA) |
|
|
Dash # |
Description |
|
|
-021 |
NH / TCO
with Eurocord (DCE Hub) |
|
|
-022 |
NH / MPR
with Eurocord (DCE Hub) (India) |
|
|
-023 |
NH Carbon
model with Eurocord (DCE Hub) |
|
|
-024 |
NH Touch
Screen model with Eurocord (DCE Hub) |
|
|
-025 |
NH Kit
with Speakers and Eurocord |
|
|
-A91 |
NH / TCO
without power cord (Dubai hub) |
|
|
-A92 |
NH / MPR
without power cord (Dubai hub) |
|
|
-031 |
NH / TCO
with UK Cord (UK Hub) |
|
|
-032 |
NH / MPR
with UK Cord (UK Hub) |
|
|
-033 |
NH / TCO
carbon with UK Cord |
|
|
-035 |
NH Kit
with Speakers and UK Cord |
|
|
-B21 |
SH / MPR
without power cord (S. Africa Hub) |
|
|
-B23 |
SH / TCO
without power cord (S. Africa Hub) |
|
|
-B27 |
SH / TCO
Carbon without power cord (S. Africa Hub) |
|
PACIFIC /
AUSTRALIA (APD) |
|
|
Dash # |
Description |
|
|
-B22 |
NH / MPR
without power cord |
|
|
-B24 |
NH / TCO
without power cord |
|
|
-B25 |
EH Carbon
model without power cord |
|
|
-B26 |
NH Touch
Screen model without power cord |
|
|
-011 |
SH model
with AUZ/NZ power cord |
|
|
-015 |
SH model
with speakers AUZ/NZ power cord |
|
|
-012 |
SH Carbon
model with AUZ/NZ power cord |
|
|
-AD1 |
NH model
for Korea |
|
|
-AD2 |
NH Carbon
model for Korea |
|
|
-B28 |
EH model
without power cord |
|
|
-B35 |
EH model
with speakers no power cord (Singapore) |
|
GREATER CHINA
(GCD) |
|
|
Dash # |
Description |
|
|
-AA1 |
NH /
China Kit with CCIB label (Local Sales) |
|
|
-AA2 |
NH/
Carbon China Kit with CCIB label (Local Sales) |
|
|
-KA1 |
NH /
China Kit with CCIB label (External Sales/Bundles in HK) |
|
|
-AB1 |
NH /
Taiwan kit, mfg. in Taiwan |
|
JAPAN (CKK |
|
|
|
Dash # |
Description |
|
|
-291 |
NH /
Japan Kit with 3-2 pin adapter |
|
|
-292 |
NH Carbon
Japan Kit with 3-2 pin adapter |
|
|
|
| TFT Country Code Key |
EUROPE, MIDDLE
EAST & AFRICA (EMEA) |
|
|
Dash # |
Description |
|
|
-AA1 |
NH /
China Kit with CCIB label (Local Sales) |
|
|
-AA2 |
NH/
Carbon China Kit with CCIB label (Local Sales) |
|
|
-KA1 |
NH /
China Kit with CCIB label (External Sales/Bundles in HK) |
|
|
-AB1 |
NH /
Taiwan kit, mfg. in Taiwan |
|
NORTH AMERICA |
|
|
|
Dash # |
Description |
|
|
-001 |
NA |
|
|
-B24 |
All NA/LA
models |
|
APD |
|
|
|
Dash # |
Description |
|
|
-011 |
Australia/NZ |
|
JAPAN (CKK) |
|
|
|
Dash # |
Description |
|
|
-291 |
Japan |
|
|
|
| External Tape Drives |
(Note:
The ProLiant 6400R only supports External Tape Drives) |
|
External 40/80-GB DLT Drive |
146197-B21 |
|
External 40/80-GB DLT Drive
(Japan) |
146197-291 |
|
External 35/70-GB DLT Drive |
242521-B21 |
|
External 35/70-GB DLT Drive
(Japan) |
242521-291 |
|
External 20/40-GB DLT Drive
(Opal) |
340744-B22 |
|
External 20/40-GB DLT Drive
(Opal) (Japan) |
340744-292 |
|
External 20/40-GB DAT DDS-4 Tape
Drive |
157770-001 |
|
20/40-GB DAT 8 Cassette
Autoloader - External |
166505-001 |
|
20/40-GB DAT 8 Cassette
Autoloader External (Intl) |
166505-B31 |
|
20/40-GB DAT 8 Cassette
Autoloader External (Japan) |
166505-291 |
|
External AIT 50-GB Tape Drive |
157767-001 |
|
External AIT 50-GB Tape Drive
(Intl) |
157767-B31 |
|
External AIT 50-GB Tape Drive
(Japan) |
157767-291 |
|
External AIT 35-GB Tape Drive |
388507-001 |
|
External AIT 35-GB Tape Drive
(Japan) |
388507-291 |
|
External AIT 35-GB Tape Drive
(Intl) |
388507-B31 |
|
External AIT 35-GB Tape Drive
(Japan) |
388507-291 |
|
DDS-4 Media (10 pack) |
152842-001 |
|
20/40-GB DAT 8 Cassette Magazine
with Media |
171532-B21 |
|
12-GB DDS-3 DAT Cassette (10
pack) |
295515-B21 |
|
DAT Cleaning Cassette |
242781-001 |
|
AIT 50-GB Data Cassette (five
pack) |
152841-001 |
|
AIT 35-GB Data Cassette (five
pack) |
402371-B21 |
|
DLT IV Drive Cartridge (single) |
295194-B21 |
|
DLT IV Drive Cartridge (seven
pack) |
295192-B21 |
|
DLT Cleaning Cartridge |
199704-001 |
|
|
|
| External Storage |
Compaq StorageWorks
Enclosure Model 4214R (rack-mountable) |
103381-001 |
|
Compaq StorageWorks Enclosure
Model 4214R (rack-mountable) (Intl) |
103381-B31 |
|
Compaq StorageWorks Enclosure
Model 4214R (rack-mountable) (Japan) |
103381-291 |
|
Compaq StorageWorks Enclosure
Model 4254R (rack-mountable) |
138151-001 |
|
Compaq StorageWorks Enclosure
Model 4254R (rack-mountable) (Intl) |
138151-B31 |
|
Compaq StorageWorks Enclosure
Model 4254R (rack-mountable) (Japan) |
138151-291 |
|
Compaq StorageWorks Enclosure
Model 4314R (rack-mountable) |
190209-001 |
|
Compaq StorageWorks Enclosure
Model 4314R (rack-mountable) (Intl) |
190209-B31 |
|
Compaq StorageWorks Enclosure
Model 4314R (rack-mountable) (Japan) |
190209-291 |
|
Compaq StorageWorks Enclosure
Model 4354R (rack-mountable) |
190211-001 |
|
Compaq StorageWorks Enclosure
Model 4354R (rack-mountable) (Intl) |
190211-B31 |
|
Compaq StorageWorks Enclosure
Model 4354R (rack-mountable) (Japan) |
190211-291 |
|
Note:
The Compaq StorageWorks Enclosure 4200/4300 Family support the Wide Ultra2/Ultra3 1² Hot Plug Hard Drives. |
|
Rack-Mountable SCSI Storage
Expander II |
332607-001 |
|
Rack-Mountable SCSI Storage
Expander II (Intl) |
332607-B21 |
|
Rack-Mountable SCSI Storage
Expander II (Japan) |
332607-291 |
|
Rack-Mountable ProLiant Storage
System Model UE |
348700-001 |
|
Rack-Mountable ProLiant Storage
System Model UE (Intl) |
348700-B31 |
|
Rack-Mountable ProLiant Storage
System Model UE (Japan) |
348700-291 |
|
Rack-Mountable ProLiant Storage
System Model U2 |
304100-B22 |
|
Rack-Mountable ProLiant Storage
System Model U2 (Intl) |
304104-B32 |
|
Rack-Mountable ProLiant Storage
System Model U2 (Japan) |
304104-292 |
|
Note:
The Compaq ProLiant Storage System Models UE and U2 support the Wide-Ultra SCSI-3 Drives. |
|
ProLiant Storage System/U
Redundant Power Supply |
224206-001 |
|
ProLiant Storage System/U
Redundant Power Supply (Intl) |
224214-001 |
|
StorageWorks Enclosure 4200
Redundant Power Supply Option |
119826-B21 |
|
StorageWorks Enclosure 4200
Ultra2 Dual Bus I/O Module Option |
119829-B21 |
|
StorageWorks Enclosure 4200
Ultra3 Single Bus I/O Module Option |
190212-B21 |
|
StorageWorks Enclosure 4200
Ultra3 Dual Bus I/O Module Option |
190213-B21 |
|
StorageWorks Enclosure Tower to
Rack Conversion Kit |
150213-B21 |
|
|
|
| StorageWorks DLT
Departmental Library |
TL895 (96 slot) library unit, 2
drive |
349350-B22 |
| TL895 (96 slot) library unit, 3
drive |
349350-B23 |
|
TL895 (96 slot) library unit, 4
drive |
349350-B24 |
|
TL895 (96 slot) library unit, 5
drive |
349350-B25 |
|
TL895 (96 slot) library unit, 6
drive |
349350-B26 |
|
TL895 (96 slot) library unit, 7
drive |
349350-B27 |
|
TL891DLX DLT Library, 1 drive,
Rack, LVD |
157305-B21 |
|
TL891DLX DLT Library, 2 drive,
Rack, LVD |
157305-B22 |
|
TL891 DLT library unit, 1 drive
Rack, FWD |
120876-B21 |
|
TL891 DLT library unit, 2 drive
Rack, FWD |
120876-B22 |
|
TL881 DLT Library, 1 drive Rack,
FWD |
128669-B21 |
|
TL881 DLT Library, 2 drive Rack,
FWD |
128669-B22 |
|
Add-On 20/40-GB Drive for TL881 |
128671-B21 |
|
Add-On 35/70-GB Drive for TL891 |
120878-B21 |
|
40/80 DLT Add-On Drive for
TL891DLX |
157303-B21 |
|
40/80 DLT Add-On Drive for TL8x1,
HVD |
157304-B21 |
|
StorageWorks Dual Channel
Ultra-Wide Differential Library Host Bus Adapter Note: The StorageWorks Dual Channel Ultra-Wide Differential Library
Host Bus Adapter is required to support FWD-based tape libraries. |
157299-B21 |
|
DLT7000 drive upgrade kit
(Available for TL895 DLT Library only.) |
349351-B21 |
|
DLT7000 drive upgrade kit (Japan)
(Available for TL895 DLT Library only.) |
349351-291 |
|
MiniLibrary Data Unit
(Available for TL881, TL891 DLT Libraries only.) |
128670-B21 |
|
MiniLibrary Expansion Unit
(Available for TL881, TL891 DLT Libraries only.) |
120877-B21 |
|
MiniLibrary Expansion Unit, LVD
(Available for TL891DLX DLT Libraries only.) |
157301-B21 |
|
DLT IV Data Cartridges (single
pack) |
295194-B21 |
|
DLT IV Data Cartridges (7 pack) |
295192-B21 |
|
DLT Cleaning Cartridge |
199704-001 |
|
MiniLibrary pass-through
Mechanism Kit
(Available for TL881, TL891 DLT Libraries only.) |
120880-B21 |
|
10 Slot Magazine
(Available for TL881, TL891 DLT Libraries only.) |
120881-B21 |
|
MiniLibrary Table Top to Rack
Mount Conversion Kit, Metric/RETMA racks
(Available for TL881, TL891 DLT Libraries only.) |
120882-B21 |
|
MiniLibrary Table Top to Rack
Mount Conversion Kit, Compaq racks
(Available for TL881, TL891 DLT Libraries only.) |
120883-B21 |
|
|
|
| Automated AIT Tape
Library Solution |
SSL2020 AIT Mini-Library 1 drive,
20 slot Table Top |
175195-B21 |
| SSL2020 AIT Mini-Library 2 drive,
20 slot Table Top |
175195-B22 |
|
SSL2020 AIT Mini-Library 1 drive,
20 slot Rackmount |
175196-B21 |
|
SSL2020 AIT Mini-Library 2 drive,
20 slot Rackmount |
175196-B22 |
|
SSL2020 AIT Library Pass Thru
with Transport |
175312-B21 |
|
SSL2020 AIT Library Pass Thru
Extender |
175312-B22 |
|
AIT 50GB Drive Add-On LVD Drive
for SSL2020 AIT Library |
175197-B21 |
|
19 Slot Magazine for SSL2020 AIT
Library |
175198-B21 |
|
AIT 50-GB Data Cassette (5 pack) |
152841-001 |
|
AIT Cleaning Cassette |
402374-B21 |
|
Tabletop to Rackmount Upgrade Kit
for SSL2020 AIT Library, Compaq Rack |
175199-B21 |
|
Tabletop to Rackmount Upgrade Kit
for SSL2020 AIT Library, RETMA racks |
175199-B22 |
|
|
|
| Tape Array
Solution |
TA1000 AIT Tape Array, Rackmount
(US) |
175005-001 |
| TA1000 AIT Tape Array, Rackmount
(Intl) |
175005-B31 |
|
TA1000 AIT Tape Array, Rackmount
(Japan) |
175005-291 |
|
AIT 50-GB Data Cassette (5 pack) |
152841-001 |
|
AIT Cleaning Cassette |
402374-B21 |
|
DLT Tape Array III Model 40/80-4 |
161140-001 |
|
DLT Tape Array III Model 40/80-4
(Intl) |
161140-B31 |
|
DLT Tape Array III Model 40/80-4
(Japan) |
161140-291 |
|
DLT Tape Array III Model 0 |
168047-001 |
|
DLT Tape Array III Model 0
(Intl) |
168047-B31 |
|
DLT Tape Array III Model 0
(Japan) |
168047-291 |
|
DLT Tape Array Model 0 |
199860-001 |
|
DLT Tape Array II Model 35/70-4
no software |
295165-001 |
|
DLT Tape Array II Model 35/70-4
no software (Intl) |
295165-B31 |
|
DLT IV Data Cartridges (single
pack) |
295194-B21 |
|
DLT IV Data Cartridges (7 pack) |
295192-B21 |
|
DLT Cleaning Cartridge |
199704-001 |
|
DLT Library Tabletop Conversion
Kit |
350384-B21 |
|
Tape Array Cable Kit
(Available for the DLT Tape Array and
DLT Tape Array II only.) |
242427-001 |
|
DLT Tape Array III Model 0, LVD
Cable Kit Note: Available for the DLT
Tape Array III Model. |
168048-B21 |
|
|
|
| StorageWorks
Enterprise Tape Library |
ESL9326DX Enterprise Library 6
40/80 Drive |
161265-B23 |
| ESL9326DX Enterprise Library 8
40/80 Drive |
161265-B24 |
|
ESL9326DX Enterprise Library 10
40/80 Drive |
161265-B25 |
|
ESL9326DX Enterprise Library 12
40/80 Drive |
161265-B26 |
|
ESL9326DX Enterprise Library 14
40/80 Drive |
161265-B27 |
|
ESL9326DX Enterprise Library 16
40/80 Drive |
161265-B28 |
|
ESL9326D, 0 Drive Unit |
146205-B21 |
|
ESL9236D Enterprise Library 6
35/70 Drive |
146205-B23 |
|
ESL9236D Enterprise Library 8
35/70 Drive |
146205-B24 |
|
ESL9236D Enterprise Library 10
35/70 Drive |
146205-B25 |
|
ESL9236D Enterprise Library 12
35/70 Drive |
146205-B26 |
|
ESL9236D Enterprise Library 14
35/70 Drive |
146205-B27 |
|
ESL9236D Enterprise Library 16
35/70 Drive |
146205-B28 |
|
ESL9198DLX Enterprise Library
LVD, 0 Devices |
194993-B21 |
|
ESL9198DLX Enterprise Library 2
40/80 Drive |
194993-B22 |
|
ESL9198DLX Enterprise Library 4
40/80 Drive |
194993-B24 |
|
ESL9198DLX Enterprise Library 8
40/80 Drive |
194993-B28 |
|
ESL9000 Add-On 40/80-GB DLT Drive |
161267-B21 |
|
ESL9000 Add-On LVD 40/80-GB DLT
Drive in Hot Plug Canister |
221248-B21 |
|
Library Ready 35/70GB Hot-swap
drive for ESL9326D |
146209-B21 |
|
LVD Extender Kit |
221249-B21 |
|
ESL 9000 Pass Through Kit for
Multi Unit Connectivity |
161268-B21 |
|
StorageWorks Dual Channel
Ultra-Wide Differential Library Host Bus Adapter Note: The StorageWorks Dual Channel Ultra-Wide Differential Library
Host Bus Adapter is required to support the ESL9236D Library. |
157299-B21 |
|
DLT IV Data Cartridges (single
pack) |
295194-B21 |
|
DLT IV Data Cartridges (7 pack) |
295192-B21 |
|
DLT Cleaning Cartridge |
199704-001 |
|
|
|
| StorageWorks RAID
Array 4100 |
StorageWorks Raid Array 4100
(rack) |
146013-001 |
| StorageWorks Raid Array 4100
(rack) (Intl) |
146013-B31 |
|
StorageWorks Raid Array 4100
(rack) (Japan) |
146013-291 |
|
Fibre Channel Storage Hub 12 |
295573-001 |
|
Fibre Channel Storage Hub 12
(Intl) |
295573-B31 |
|
Fibre Channel Storage Hub 12
(Japan) |
295573-291 |
|
Fibre Channel Storage Hub 7 |
234453-001 |
|
Fibre Channel Storage Hub 7
(Intl) |
234453-B31 |
|
Fibre Channel Storage Hub 7
(Japan) |
234453-291 |
|
Compaq Storage Hub 12 Management
Option |
159262-B21 |
|
StorageWorks Raid Array 4000
Redundant Array Controller |
223187-B21 |
|
StorageWorks Fibre Channel
Arbitrated Loop Switch 8 |
177862-B21 |
|
StorageWorks Fibre Channel
Arbitrated Loop Switch 8 (Japan) |
177862-291 |
|
StorageWorks Fibre Channel
Arbitrated Loop 3-Port Expansion Module |
177863-B21 |
|
64-bit/66-MHz Fibre Channel Host
Adapter |
120186-B21 |
|
64-bit/66-MHz Fibre Channel Host
Adapter (Japan) |
120186-291 |
|
Fibre Channel Host Adapter
Redundancy Kit |
174681-B21 |
|
GBIC-SW Connector Kit (two each) |
234459-B21 |
|
GBIC-LW Connector Kit (two each) |
340412-B21 |
|
Fibre Channel Connection Kit, 3
SW GBICS, 2 Cables |
380579-B21 |
|
Fibre Channel Connection Kit, 2
SW GBICS, 2 Cables |
380596-B21 |
|
Fibre Channel Short Wave GBIC |
380561-B21 |
|
Fibre Channel Long Wave GBIC |
127508-B21 |
|
2m Multi-Mode Fibre Channel Cable |
234457-B21 |
|
5m Multi-Mode Fibre Channel Cable |
234457-B22 |
|
15m Multi-Mode Fibre Channel
Cable |
234457-B23 |
|
30m Multi-Mode Fibre Channel
Cable |
234457-B24 |
|
50m Multi-Mode Fibre Channel
Cable |
234457-B25 |
|
Raid Array 4000 Redundant Power
Supply |
224206-001 |
|
Raid Array 4000 Tower to Rack
Conversion Kit |
297162-B21 |
|
Raid Array 4100 Rack to Tower
Conversion Kit |
154253-B21 |
|
Compaq Storage Hub 7 Universal
Rack Mount Kit |
136127-B21 |
|
Upgrade Kit for Proliant Storage
System F and F1 |
296324-B21 |
|
Fibre Channel Array Controller
64-MB Cache Upgrade Kit |
262398-B21 |
|
Raid Array 4100 Rack to Tower
Conversion Kit |
154253-B21 |
|
Fibre Channel Troubleshooting Kit |
234468-B21 |
|
|
|
| StorageWorks RAID Array 8000 |
Departmental
Pedestal Models |
|
|
|
RA8000 FC Single
Controller (Opal) |
400553-B22 |
|
|
RA8000 FC Dual
Controller (Opal) |
400552-B22 |
|
|
Expansion Cabinet 24
slot (Opal) |
380570-B22 |
|
Rack Mountable
Models |
|
|
|
RA8000 FC Single
Controller |
400554-B21 |
|
|
RA8000 FC Dual
Controller |
400700-B21 |
|
|
Expansion Cabinet 24
slot |
380568-B21 |
|
|
|
| StorageWorks Enterprise Storage
Array 12000 |
ESA Building
Blocks |
|
|
|
High-Capacity/General
Business - Dual Controllers 48 slots, 60 Hz (Opal) |
400557-002 |
|
|
High-Capacity/General
Business - Dual Controllers 48 slots, 50 Hz (Opal) |
400558-B22 |
|
|
High Bandwidth Quad
controllers 48 slots, 60 Hz (Opal) |
400555-002 |
|
|
High Bandwidth Quad
controllers 48 slots, 50 Hz (Opal) |
400556-B22 |
|
|
Single Expansion Dual
controllers 24 slots, 25U extra cabinet space, 60 Hz (Opal) |
400559-002 |
|
|
Single Expansion Dual
controllers 24 slots, 25U extra cabinet space, 50 Hz (Opal) |
400560-B22 |
|
|
Expansion enclosure
48 slots, 60 Hz (Opal) |
380640-002 |
|
|
Expansion enclosure
48 slots, 50 Hz (Opal) |
380650-B22 |
|
|
|
| StorageWorks
Modular Array 6000 |
MA6000 D14 |
187738-B21 |
| MA6000 S14 |
187739-B21 |
|
|
|
| StorageWorks
Modular Array 8000/Enterprise Modular Array 12000 |
EMA12000 D14 60Hz |
175990-B21 |
| EMA12000 D14 50Hz |
175990-B22 |
| EMA12000 S14 60Hz |
175991-B21 |
|
EMA12000 S14 50Hz |
175991-B22 |
|
MA8000 60Hz |
175992-B21 |
|
MA8000 50Hz |
175992-B22 |
|
EMA12000 Blue 60Hz |
175993-B21 |
|
EMA12000 Blue 50Hz |
175993-B22 |
|
|
|
| StorageWorks
Options |
Fibre Channel Tape Controller -
II |
152975-001 |
| Fibre Channel Tape Controller
II (Intl) |
152975-B31 |
|
Fibre Channel Tape Controller
II (Japan) |
152975-291 |
|
Fibre Channel Storage Switch 16 |
380578-B21 |
|
Fibre Channel Storage Switch 8 |
380591-B21 |
|
Fibre Channel SAN Switch/8 with
Fabric Operating Software |
158222-B21 |
|
Fibre Channel SAN Switch/16 with
Fabric Operating Software |
158223-B21 |
|
F200 Clustering Kit |
380357-B21 |
|
|
|
| Uninterruptible
Power Systems |
Rack-Mountable UPS R1500 (100-127
VAC) (NA) |
242704-001 |
| Rack-Mountable UPS R1500h
(208-240 VAC) (Intl) |
242704-002 |
|
Rack-Mountable UPS R1500j
(100-127 VAC) (Japan) |
242704-291 |
|
Rack-Mountable UPS R3000 (100-127
VAC) (NA) |
242705-001 |
|
Rack-Mountable UPS R3000h
(208-240 VAC) (Intl) |
242705-002 |
|
Rack-Mountable UPS R3000h-NA
(208-240 VAC) NDC (non-detached cord) |
242705-003 |
|
Rack-Mountable UPS R3000j
(100-127 VAC) (Japan) |
242705-291 |
|
Compaq UPS R3000 XR (120V) (NA) |
192186-001 |
|
Compaq UPS R3000 XR (100V)
(Japan) |
192186-291 |
|
Compaq UPS R3000 XR (208V) (NA) |
192186-002 |
|
Compaq UPS R3000 XR (208V)
(Japan) |
192186-292 |
|
Compaq UPS R3000 XR (230V) (EURO,
IEC-309P) |
192186-B32 |
|
Compaq UPS R3000 XR (208V)
(Intl - detachable cord) |
192186-B31 |
|
Rack-Mountable UPS R6000 (208V)
(NA) |
347207-001 |
|
Rack-Mountable UPS R6000 (230V)
(Int'l) |
347207-B31 |
|
Rack-Mountable UPS R6000 (200V)
(Japan) |
347207-291 |
|
R6000 Extended Runtime Module
Note: Available for the UPS R6000
Models only. |
347224-B21 |
|
Extended Runtime Battery, R3000
XR
Note: Available for the UPS R3000 XR
Models only. |
192188-B21 |
|
Six-Port Card
Note: Available for the UPS R3000 XR
Models only. |
192185-B21 |
|
SNMP/Serial Port Card
Note: Available for the UPS R3000 XR
Models only. |
192189-B21 |
|
SNMP-EN Adapter |
347225-B21 |
|
High to Low Voltage Transformer
(250VA) |
388643-B21 |
|
Multi-Server UPS Card |
123508-B21 |
|
Scalable UPS Card |
123509-B21 |
|
Compaq High Voltage PDU Right
Angled Cable Kit (IEC14) (For use
with Compaq High-Voltage PDUs, this is a 15-Amp power cord with a right angle connector on
the side that plugs into the ProLiant 6400R server. The right angle connection at the
server improves cable management at the rear of the server.) |
142257-005 |
| Compaq Rack
9000 Series (Opal) |
Compaq Rack 9142 (42U)
Pallet |
120663-B21 |
| Compaq Rack 9142 (42U)
Shock Pallet |
120663-B22 |
|
Compaq Rack 9142 (42U)
Crafted |
120663-B23 |
|
Compaq Rack 9136 (36U)
Pallet |
120664-B21 |
|
Compaq Rack 9136 (36U)
Shock Pallet |
120664-B22 |
|
Compaq Rack 9136 (36U)
Crafted |
120664-B23 |
|
Compaq Rack 9122 (36U)
Pallet |
120665-B21 |
|
Compaq Rack 9122 (36U)
Shock Pallet |
120665-B22 |
|
Compaq Rack 9122 (36U)
Crafted |
120665-B23 |
|
Note:
-B21 part numbers are used for all Geos.
B22 part numbers are used to ship configured racks (by custom systems, VARs, and
Channels.)
B23 part numbers are used for air shipments. |
|
|
|
| Rack Options for
Compaq Rack 9000 Series |
Baying/Coupling Kit |
120669-B21 |
| Rack 9142 Side Panel |
120670-B21 |
|
Rack 9136 Side Panel |
120671-B21 |
|
Ballast Option Kit |
120672-B21 |
|
Stabilizer Option Kit |
120673-B21 |
|
Rack Rail Adapter Kit (25"
depth) |
120675-B21 |
|
Fan (110 VAC) Roof Mount |
120677-B21 |
|
Fan (220 VAC) Roof Mount |
120678-B21 |
|
9142 Extension Kit |
120679-B21 |
|
Grounding Rack Option Kit |
120682-B21 |
|
Cable Management D-Rings Kit |
168233-B21 |
|
Rack Blanking Panels (1U) |
189453-B21 |
|
Rack Blanking Panels (2U) |
189453-B22 |
|
Rack Blanking Panels (3U) |
189453-B23 |
|
Rack Blanking Panels (4U) |
189453-B24 |
|
Rack Blanking Panels (5U) |
189453-B25 |
|
9136 Extension Kit |
218216-B21 |
|
9142 Short Rear Door |
218217-B21 |
|
9136 Short Rear Door |
218218-B21 |
|
|
|
| Rack Options for
Compaq Rack 7000 Series |
Rack Sidewall Kit (42U only) |
165652-001 |
| Rack Coupling Kit (42U only) |
165664-001 |
|
Stabilizing Feet (42U only) |
189907-001 |
|
High Air Flow Rack Door Insert
for 7122 |
157847-B21 |
|
High Air Flow Rack Door Insert
for 7142 |
327281-B21 |
|
High Air Flow Rack Door Insert
for 7142 (six pack) |
327281-B22 |
|
Compaq Rack Extension Kit for
7142 |
154392-B21 |
|
|
|
| Rack Options for
Compaq Rack 7000 and 9000 Series |
Sliding Shelf Kit |
332564-B21 |
| Monitor Utility Shelf |
303606-B21 |
|
Rack Blanking Panel Kit for Rack
7000 series (Beach Gray) (U.S.) |
169940-001 |
|
Rack Blanking Panel Kit for Rack
9000 series(Opal) (U.S.) |
169940-B21 |
|
Compaq Networking Cable
Management Kit |
292407-B21 |
|
Compaq Networking Recessed Rail
Management Kit |
292406-B21 |
|
Compaq Power Distribution
Unit-24A Low Voltage PDU |
295363-001 |
|
Compaq Power Distribution
Unit-24A Low Voltage PDU (Japan) |
295363-291 |
|
Compaq Power Distribution
Unit-16A High Voltage PDU (cord attached) (US) |
295363-002 |
|
Compaq Power Distribution
Unit-16A High Voltage, 16A (detachable cord) (NA, Int'l) |
295363-B21 |
|
Compaq Power Distribution
Unit-24A High Voltage PDUh-NDC (non-detached cord) (Int'l) |
295363-B32 |
|
Compaq Power Distribution
Unit-24A High Voltage (NA only) |
295363-003 |
|
Compaq Dual Input Power
Distribution Unit-24A High Voltage (NA only) |
191186-001 |
|
Compaq High Voltage PDU Right
Angled Cable Kit (IEC13-IEC14)
(The 10-Amp AC cord which ships standard with the Compaq ProLiant DL580 utilizes a right
angle plug on the server side (the side that plugs into the server) to avoid interference
with the Cable Management Arm. Compaq High Voltage PDUs ship standard with 15-Amp AC cords
that incorporate straight plugs on the server side. The optional Compaq High Voltage PDU
Right Angled Cable Kit (P/N 142257-004) provides a right angle version of the 15-Amp AC
cord. When deploying Compaq High Voltage PDUs with the Compaq ProLiant DL580, you may
choose to simplify cable management at the rear of the server chassis by installing this
option kit.) |
142257-004 |
|
Server Console Switch 1 x 2 port
(100-230 VAC) |
120206-001 |
| Server Console Switch 1 x 2 port
(100-230 VAC) (Intl) |
120206-B31 |
|
Server Console Switch 1 x 2 port
(100-230 VAC) (Japan) |
120206-291 |
|
Server Console Switch 1 x 4 port
(100-230 VAC) |
400336-001 |
|
Server Console Switch 1 x 4 port
(100-230 VAC) (Intl) |
400336-B31 |
|
Server Console Switch 1 x 4 port
(100-230 VAC) (Japan) |
400336-291 |
|
Server Console Switch 1 x 8 port
(100-230 VAC) |
400337-001 |
|
Server Console Switch 1 x 8 port
(100-230 VAC) (Intl) |
400337-B31 |
|
Server Console Switch 1 x 8 port
(100-230 VAC) (Japan) |
400337-291 |
|
Server Console Switch 2 x 8 port
(100-230 VAC) |
400338-001 |
|
Server Console Switch 2 x 8 port
(100-230 VAC) (Intl) |
400338-B31 |
|
Server Console Switch 2 x 8 port
(100-230 VAC) (Japan) |
400338-291 |
|
Server Console Switch 2 x 8 port
(48VDC) |
400542-B21 |
|
CPU to Server Console Cable,
12 |
110936-B21 |
|
CPU to Server Console Cable,
20 |
110936-B22 |
|
CPU to Server Console Cable,
40 |
110936-B23 |
|
CPU to Server Console Cable,
3 |
110936-B24 |
|
CPU to Server Console Cable,
6 |
110936-B25 |
|
CPU to Server Console Cable
(Plenum Rated) 20 |
149363-B21 |
|
CPU to Server Console Cable
(Plenum Rated) 40 |
149364-B21 |
|
Switch Box Connector Kit (115V) |
144007-001 |
|
Switch Box Connector Kit (230V) |
144007-002 |
|
Switch Box Connector Kit (high
voltage) (Intl) |
144007-B33 |
|
Keyboard with Hot Keys and
Trackball (US) |
158649-001 |
|
Keyboard with Hot Keys and
Trackball (UK) |
158649-003 |
|
Keyboard with Hot Keys and
Trackball (German) |
158649-004 |
|
Keyboard with Hot Keys and
Trackball (French) |
158649-005 |
|
Keyboard with Hot Keys and
Trackball (Italian) |
158649-006 |
|
Keyboard with Hot Keys and
Trackball (Spanish) |
158649-007 |
|
Keyboard with Hot Keys and
Trackball (Danish) |
158649-008 |
|
Keyboard with Hot Keys and
Trackball (Norwegian) |
158649-009 |
|
Keyboard with Hot Keys and
Trackball (Swedish) |
158649-010 |
|
Keyboard with Hot Keys and
Trackball (Swiss) |
158649-011 |
|
Keyboard with Hot Keys and
Trackball (Portuguese) |
158649-013 |
|
Keyboard with Hot Keys and
Trackball (Belgian) |
158649-018 |
|
Keyboard with Hot Keys and
Trackball (Japan) |
158649-291 |
|
Keyboard with Hot Keys and
Trackball (Intl) |
158649-B36 |
|
Rack Internal Trackball Keyboard
(Opal) (UK) |
185152-036 |
|
Rack Internal Trackball Keyboard
(Opal) (Germany) |
185152-046 |
|
Rack Internal Trackball Keyboard
(Opal) (France) |
185152-056 |
|
Rack Internal Trackball Keyboard
(Opal) (Italy) |
185152-066 |
|
Rack Internal Trackball Keyboard
(Opal) (Spain) |
185152-076 |
|
Rack Internal Trackball Keyboard
(Opal) (Denmark) |
185152-086 |
|
Rack Internal Trackball Keyboard
(Opal) (Norway) |
185152-096 |
|
Rack Internal Trackball Keyboard
(Opal) (Sweden/Finland) |
185152-106 |
|
Rack Internal Trackball Keyboard
(Opal) (Switzerland) |
185152-116 |
|
Rack Internal Trackball Keyboard
(Opal) (Portugal) |
185152-136 |
|
Rack Internal Trackball Keyboard
(Opal) (Belgium) |
185152-186 |
|
Rack Internal Trackball Keyboard
(Opal) (Japan) |
185152-296 |
|
Rack Internal Trackball Keyboard
(Opal) (US) |
185152-406 |
| Rack Internal Trackball Keyboard
(Opal) (Intl) |
185152-B36 |
|
1U Rack Keyboard Drawer |
338056-B21 |
|
Keyboard/Monitor/Mouse extension
cables |
169989-001 |
|
|
|
| Rack Options for Third Party
Cabinet Racks |
Depth Adjustable Fixed Rails |
332558-B21 |
|
|
|
| Other |
Internal Ultra3 Cable Option Kit,
HP
(In order to store data at Wide Ultra3
SCSI speeds (160MB/sec), customers need three components:
Wide Ultra3 SCSI Adapter or Array Controller
Wide Ultra3 SCSI Hard Drives
Wide Ultra3 SCSI capable cable or server backplaneThe ProLiant 6400R 500 MHz and 550
MHz Models are not configured with an Ultra3 SCSI capable cable. Therefore, customers are
encouraged to purchase and install the Internal Ultra3 Cable Option Kit, HP (PN
166390-B21) when upgrading their server to use Wide Ultra3 SCSI Adapters, Array
Controllers, and hard drives.) |
166390-B21 |
|
|
|
| Service Upgrades (CarePaqs) |
Hardware
Services 4-Hour On-site Service |
|
|
4-Hour On-site
Service, 9-Hour x 5-Day Coverage, 3 Years (2-5-2 Part Number for U.S.) |
FM-MI4HR-36 |
|
|
4-Hour On-site
Service, 9-Hour x 5-Day Coverage, 3 Years (2-5-2 Part Number for Canada) |
FP-MI4HR-36 |
|
|
4-Hour On-site
Service, 9-Hour x 5-Day Coverage, 3 Years (6-3 Part Number for U.S.) |
401783-002 |
|
|
4-Hour On-site
Service, 9-Hour x 5-Day Coverage, 3 Years (6-3 Part Number for Canada) |
401783-122 |
|
|
4-Hour On-site
Service, 9-Hour x 5-Day Coverage, 3 Years (6-3 Part Number for EMEA) |
324418-022 |
|
|
4-Hour On-site
Service, 24-Hour x 7-Day Coverage, 3 Years (2-5-2 Part Number for U.S.) |
FM-MI724-36 |
|
|
4-Hour On-site
Service, 24-Hour x 7-Day Coverage, 3 Years (2-5-2 Part Number for Canada) |
FP-MI724-36 |
|
|
4-Hour On-site
Service, 24-Hour x 7-Day Coverage, 3 Years (6-3 Part Number for U.S.) |
401782-002 |
|
|
4-Hour On-site
Service, 24-Hour x 7-Day Coverage, 3 Years (6-3 Part Number for Canada) |
401782-122 |
|
|
4-Hour On-site
Service, 24-Hour x 7-Day Coverage, 3 Years (6-3 Part Number for EMEA) |
376911-022 |
|
Installation
& Start-up Services |
|
|
Hardware Installation
(2-5-2 Part Number for U.S.) |
FM-MIINS-IN |
|
|
Hardware Installation
(2-5-2 Part Number for Canada) |
FP-MIINS-IN |
|
|
Hardware Installation
(6-3 Part Number for U.S.) |
401793-002 |
|
|
Hardware Installation
(6-3 Part Number for Canada) |
401793-122 |
|
|
Hardware Installation
(6-3 Part Number for EMEA) |
Quote |
|
|
O/S & Hardware
Installation (2-5-2 Part Number for U.S.)
(Hardware installation plus two days
O/S start-up activity (installation, configuration, network access & orientation.)) |
FP-CXHSI-03 |
|
|
O/S & Hardware
Installation (6-3 Part Number for U.S.)
(Hardware installation plus two days
O/S start-up activity (installation, configuration, network access & orientation.)) |
160557-002 |
|
|
O/S & Hardware
Installation (6-3 Part Number for EMEA)
(Hardware installation plus two days
O/S start-up activity (installation, configuration, network access & orientation.)) |
Quote |
|
Business
Solutions Priority Service Plan Priority Level |
|
|
5 x 9 4-hour H/W, 5 x
9 2-hour O/S (NT & NetWare), Three Years (2-5-2 Part Number for U.S.) |
FP-CX103-36 |
|
|
5 x 9 4-hour H/W, 5 x
9 2-hour O/S (NT & NetWare), Three Years (2-5-2 Part Number for Canada) |
FP-CZ103-36 |
|
|
5 x 9 4-hour H/W, 5 x
9 2-hour O/S (NT & NetWare), Three Years (6-3 Part Number for U.S.) |
155325-002 |
|
|
5 x 9 4-hour H/W, 5 x
9 2-hour O/S (NT & NetWare), Three Years (6-3 Part Number for Canada) |
155325-122 |
|
|
5 x 9 4-hour H/W, 5 x
9 2-hour O/S (NT & NetWare), Three Years (6-3 Part Number for EMEA) |
179836-022 |
|
Business
Solutions Priority Service Plan Priority 24 Level |
|
|
7 x 24 4-hour H/W, 7 x 24 2-hour
O/S (NT & NetWare), Three Years (2-5-2 Part Number for U.S.) |
FP-CX203-36 |
|
|
7 x 24 4-hour H/W, 7 x 24 2-hour
O/S (NT & NetWare), Three Years (6-3 Part Number for U.S.) |
155329-002 |
|
|
7 x 24 4-hour H/W, 7 x 24 2-hour
O/S (NT & NetWare), Three Years (6-3 Part Number for EMEA) |
179841-022 |
|
Business
Solutions Priority Service Plan Priority Plus Level |
|
|
7 x 24 4-hour H/W, 7
x 24 2-hour O/S (NT & NetWare), SPS Account Review, Three Years (2-5-2 Part Number for
U.S.) |
FP-CX303-36 |
|
|
7 x 24 4-hour H/W, 7
x 24 2-hour O/S (NT & NetWare), SPS Account Review, Three Years (2-5-2 Part Number for
Canada) |
FP-CZ303-36 |
|
|
7 x 24 4-hour H/W, 7
x 24 2-hour O/S (NT & NetWare), SPS Account Review, Three Years (6-3 Part Number for
U.S.) |
155333-002 |
|
|
7 x 24 4-hour H/W, 7
x 24 2-hour O/S (NT & NetWare), SPS Account Review, Three Years (6-3 Part Number for
Canada) |
155333-122 |
|
Business
Solutions Priority Service Plan Priority Premier Level |
|
|
7 x 24 2-hour H/W, 7
x 24 1-hour O/S (NT & NetWare), SPS Account Review, Proactive Management Review, named
S/w rep, Three Years (2-5-2 Part Number for U.S.) |
FP-CX503-36 |
|
|
7 x 24 2-hour H/W, 7
x 24 1-hour O/S (NT & NetWare), SPS Account Review, Proactive Management Review, named
S/w rep, Three Years (2-5-2 Part Number for Canada) |
FP-CZ503-36 |
|
|
7 x 24 2-hour H/W, 7
x 24 1-hour O/S (NT & NetWare), SPS Account Review, Proactive Management Review, named
S/w rep, Three Years (6-3 Part Number for U.S.) |
155337-002 |
|
|
7 x 24 2-hour H/W, 7
x 24 1-hour O/S (NT & NetWare), SPS Account Review, Proactive Management Review, named
S/w rep, Three Years (6-3 Part Number for Canada) |
155337-122 |
|
Business
Solutions Priority Service Plan Priority Executive Premier Level |
|
|
7 x 24 2-hour H/W, 7
x 24 30-min. O/S (NT & NetWare), SPS Account Review, Proactive Management Review,
named S/w rep, Three Years (2-5-2 Part Number for U.S.) |
FP-CX703-36 |
|
|
7 x 24 2-hour H/W, 7
x 24 30-min. O/S (NT & NetWare), SPS Account Review, Proactive Management Review,
named S/w rep, Three Years (2-5-2 Part Number for Canada) |
FP-CZ703-36 |
|
|
7 x 24 2-hour H/W, 7
x 24 30-min. O/S (NT & NetWare), SPS Account Review, Proactive Management Review,
named S/w rep, Three Years (6-3 Part Number for U.S.) |
155341-002 |
|
|
7 x 24 2-hour H/W, 7
x 24 30-min. O/S (NT & NetWare), SPS Account Review, Proactive Management Review,
named S/w rep, Three Years (6-3 Part Number for Canada) |
155341-122 |
|
Note:
For more information, customer/resellers can contact www.Compaq.com/services. |
|
|
|
TechSpecs
| System Unit
|
Dimensions (HxWxD) Overall
(with rear fan and front handles) |
6.94 x 19. x 28.3 in |
| Chassis Footprint (HxWxD) |
6.94 x 19. x 25 in |
|
| Weight |
66 lbs |
|
|
No hard drives
installed,
one power supply |
|
|
|
|
|
|
Input Requirements |
Rated Input Voltage |
90 to 120 VAC/200 to 240 VAC |
|
|
Rated Input Frequency |
50 to 60 Hz |
|
|
Input Power |
600W @ 110 VAC/600W @ 220 VAC |
|
|
Rated Input Current |
7A (90 VAC), 5A (120 VAC), 3A
(210 VAC) |
|
BTU Rating |
2291 BTU |
|
|
SCSI Connector |
One 68-pin connector
supporting Wide Ultra2 SCSI (running in Wide-Ultra SCSI-3 mode) |
|
Power Supply
Output Power (per power supply) |
Rated Steady-State Power |
450W/450W (lowline/highline) |
|
Maximum Peak Power |
480W/480W
(lowline/highline) |
|
Temperature Range |
Operating |
50° to 95°F/
10° to 35°C |
|
Non-operating |
20° to 140°F/
29° to 60°C |
|
Shipping |
22° to 122°F/
30° to 50°C |
|
Relative Humidity
(non-condensing) |
Operating |
20% to 80% |
|
Non-operating |
5% to 90% |
|
Maximum Wet Bulb
Temperature |
101.7°F/38.7°C |
|
|
|
|
|
Acoustic Noise |
Idle
(Fixed Disk Drives Spinning) |
|
|
|
|
L WAd (BELS) |
7.2 |
|
|
|
L pAm (dBA) |
53 |
|
|
Operating
(Random Seeks to Fixed Disks) |
|
|
|
|
L WAd (BELS) |
7.3 |
|
|
|
L pAm (dBA) |
54 |
| 1.44-MB Diskette
Drive |
Diskette Size |
3.5 in |
|
| LED Indicators (front
panel) |
Green |
|
|
Read/Write Capacity per
Diskette (high/low density) |
1.44 MB/720 KB |
|
|
Drive Supported |
One |
|
|
Drive Height |
One-third |
|
|
Drive Rotation |
300 rpm |
|
|
Transfer Rate (high/low) |
500/250 Kb/s |
|
|
Bytes/Sector |
512 |
|
|
Sectors/Track (high/low) |
18/9 |
|
|
Tracks/Side (high/low) |
80/80 |
|
|
Access Times |
Track-to-Track
(high/low) |
3/6 ms |
|
|
Average (high/low) |
169/94 ms |
|
|
Settling Time |
15 ms |
|
|
Latency Average |
100 ms |
|
Cylinders (high/low) |
80/80 |
|
|
Read/Write Heads |
Two |
|
|
|
|
|
Hot Plug Wide
Ultra3 SCSI
Hard Drives |
36.4 GB 10K |
Capacity |
36400 MB |
| 176496-B22 |
Height |
1 in/25.4 mm |
|
|
Width |
3.5 in/88.9 mm |
|
|
Interface |
Wide Ultra3 SCSI |
|
|
Transfer Rate Synchronous
(Maximum) |
160 MB/s |
|
|
Seek Time
(typical reads, including settling) |
Single Track |
0.8 ms |
|
Average |
5.2 ms |
|
|
Full-Stroke |
12 ms |
|
|
Rotational Speed |
10,000 rpm |
|
|
Physical Configuration |
Logical Blocks |
71,132,000 |
|
|
Operating Temperature |
50°
to 95° F/10° to 35° C |
|
|
|
|
|
18.2 GB 10K |
Capacity |
18209.3 MB |
| 142673-B22 |
Height |
1 in/25.4 mm |
|
|
Width |
3.5 in/88.9 mm |
|
|
Interface |
Wide Ultra3 SCSI |
|
|
Transfer Rate Synchronous
(Maximum) |
160 MB/s |
|
|
Seek Time
(typical reads, including settling) |
Single Track |
0.8 ms |
|
Average |
5.2 ms |
|
|
Full-Stroke |
12 ms |
|
|
Rotational Speed |
10,000 rpm |
|
|
Physical Configuration |
Logical Blocks |
35,566,080 |
|
|
Operating Temperature |
50°
to 95° F/10° to 35° C |
|
|
|
|
|
9.1 GB 10K |
Capacity |
9100.0 MB |
| 142671-B22 |
Height |
1 in/25.4 mm |
|
|
Width |
3.5 in/88.9 mm |
|
|
Interface |
Wide Ultra3 SCSI |
|
|
Transfer Rate Synchronous
(Maximum) |
160 MB/s |
|
|
Seek Time
(typical reads, including settling) |
Single Track |
0.8 ms |
|
Average |
5.0 ms |
|
|
Full-Stroke |
12 ms |
|
|
Rotational Speed |
10,000 rpm |
|
|
Physical Configuration |
Logical Blocks |
17,773,524 |
|
|
Operating Temperature |
50°
to 95° F/10° to 35° C |
|
|
|
|
|
18.2 GB 15K |
Capacity |
18209.3 MB |
| 188122-B22 |
Height |
1 in/25.4 mm |
|
|
Width |
3.5 in/88.9 mm |
|
|
Interface |
Wide Ultra3 SCSI |
|
|
Transfer Rate Synchronous
(Maximum) |
160 MB/s |
|
|
Seek Time
(typical reads, including settling) |
Single Track |
0.8 ms |
|
Average |
5.0 ms |
|
|
Full-Stroke |
12 ms |
|
|
Rotational Speed |
15,000 rpm |
|
|
Physical Configuration |
Logical Blocks |
35,565,080 |
|
|
Operating Temperature |
50°
to 95° F/10° to 35° C |
|
|
|
|
|
9.1 GB 15K |
Capacity |
9100.0 MB |
| 188120-B22 |
Height |
1 in/25.4 mm |
|
|
Width |
3.5 in/88.9 mm |
|
|
Interface |
Wide Ultra3 SCSI |
|
|
Transfer Rate Synchronous
(Maximum) |
160 MB/s |
|
|
Seek Time
(typical reads, including settling) |
Single Track |
0.8 ms |
|
Average |
5.0 ms |
|
|
Full-Stroke |
12 ms |
|
|
Rotational Speed |
15,000 rpm |
|
|
Physical Configuration |
Logical Blocks |
17,773,524 |
|
|
Operating Temperature |
50°
to 95° F/10° to 35° C |
|
|
|
|
Hot Plug Wide
Ultra2 SCSI
Hard Drives |
18.2 GB |
Capacity |
18209.3 MB |
| 388144-B22 |
Height |
1 in/25.4 mm |
|
|
Width |
3.5 in/88.9 mm |
|
|
Interface |
Wide Ultra2 SCSI |
|
|
Transfer Rate Synchronous
(Maximum) |
80 MB/s |
|
|
Seek Time
(typical reads, including settling) |
Single Track |
0.8 ms |
|
Average |
7.0 ms |
|
|
Full-Stroke |
15 ms |
|
|
Rotational Speed |
7200 rpm |
|
|
Physical Configuration |
Logical Blocks |
35,565,080 |
|
|
Operating Temperature |
50°
to 95° F/10° to 35° C |
|
|
|
|
|
9.1 GB |
Capacity |
9100.0 MB |
| 123065-B22 |
Height |
1 in/25.4 mm |
|
|
Width |
3.5 in/88.9 mm |
|
|
Interface |
Wide Ultra2 SCSI |
|
|
Transfer Rate Synchronous
(Maximum) |
80 MB/s |
|
|
Seek Time
(typical reads, including settling) |
Single Track |
0.8 ms |
|
Average |
7.0 ms |
|
|
Full-Stroke |
15 ms |
|
|
Rotational Speed |
7200 rpm |
|
|
Physical Configuration |
Logical Blocks |
17,773,524 |
|
|
Operating Temperature |
50°
to 95° F/10° to 35° C |
|
|
|
|
24X or higher IDE
CD-ROM
Drive Slim Line |
Disk |
Applicable Disk |
CD-ROM (Mode 1 and 2) CD-DA,
CD-XA (Mode 2, Form 1 and 2)
Photo CD (Single and Multi-session)
Mixed Mode (Audio and Data combined) |
| Capacity |
550 MB (Mode 1, 12 cm) 640 MB
(Mode 2, 12 cm) |
Diameter
Rotational Speed
Center Hole
Thickness
Track Pitch |
4.7 in, 3.15 in/12 cm, 8 cm
4200 rpm maximum
0.6 in/15 mm diameter
1.2 mm
1.6 µm |
|
|
|
|
|
Block Size |
Mode 1 |
2,048 bytes |
|
|
Mode 2 |
2,340, 2,336, 1,024 bytes |
|
|
CD-DA |
2,352 bytes |
|
|
CD-XA |
2,328 bytes |
|
|
|
|
|
Interface |
IDE (ATAPI) |
|
|
|
|
|
|
Access Times (typical) |
Random |
100 ms |
|
|
Full-Stroke |
200 ms |
|
|
|
|
|
Audio Output Level |
Line-Out |
0.7 VRMS at 47 kOhms |
|
|
Headphone |
0.67 VRMS at 32 kOhms (maximum
volume) |
|
|
|
|
|
Data Transfer Rate |
Sustained |
150 KB/s (single) |
|
|
Burst |
2100 to 3600 KB/s |
|
|
|
|
|
Cache Buffer |
128 KB |
|
|
|
|
|
|
Start-up Time (typical) |
< 7 seconds |
|
|
|
|
|
|
Stop Time |
< 4 seconds |
|
|
|
|
|
|
Laser Parameters |
Type |
Semiconductor Laser GaA1As |
|
|
Wave Length |
780 ±
25 nm |
|
|
Divergence Angle |
53.5° ±
1.5° |
|
|
Output Power |
0.14 mW |
|
|
|
|
|
Operating Conditions |
Temperature |
41° to 113°F/5° to 45°C |
|
|
Humidity |
10% to 80% |
|
|
|
|
|
Dimensions |
(HxWxD, maximum) |
1.69 x 5.75 x 8.19 in/4.29 x 15 x
20.8 cm |
|
|
Weight |
2.66 lbs/1.2 kg |
|
|
|
|
| Smart Array 3200
Controller |
|
Data Compatible with all Smart
Array Controllers |
Yes |
|
Instant Upgrades to other
Smart Array Controllers |
Yes |
|
Consistent Software
Manageability Tools |
Yes |
|
|
PCI Bus |
64-bit, 33 MHz |
|
|
PCI Peak Data Transfer Rate |
266 MB/s |
|
|
SCSI Protocols Supported |
Ultra2, Wide-Ultra |
|
|
SCSI Peak Data Transfer Rate |
320 MB/s total, 80 MB/s per
channel |
|
|
Channels |
4 |
|
|
SCSI Ports (external/internal) |
4/2 |
|
|
Drives Supported (maximum) |
56 |
|
|
Note: Drives Supported (maximum) is based on use of Compaq StorageWorks
Enclosure 4200/4300 family (14 hard disk drive enclosure). |
|
|
Cache |
64-MB battery backed read-write |
|
|
RAID Support |
0, 1, 0+1, 4, 5 |
|
|
Logical Drives (maximum) |
32 |
|
|
Online Configuration |
Yes |
|
|
Online Capacity Expansion |
Yes |
|
|
Logical Drive Capacity
Extension |
Yes |
|
|
Online Stripe Size Migration |
Yes |
|
|
Online RAID Level Migration |
Yes |
|
|
Online Spare Support |
Yes |
|
|
Automatic Data Recovery |
Yes |
|
|
Drive Roaming |
Yes |
|
|
Redundant
Controllers |
No |
|
|
|
|
| Smart Array 431
Controller |
|
Data Compatible with all Smart
Array Controllers |
Yes |
|
Instant Upgrades to other
Smart Array Controllers |
Yes |
|
Consistent Software
Manageability Tools |
Yes |
|
|
PCI Bus |
64-bit, 66MHz |
|
|
PCI Peak Data Transfer Rate |
533 MB/s |
|
|
SCSI Protocols Supported |
Ultra3, Ultra2, Wide-Ultra |
|
|
SCSI Peak Data Transfer Rate |
160 MB/s |
|
|
Channels |
1 |
|
|
SCSI Ports (external/internal) |
1/1 |
|
|
Drives Supported (maximum) |
14 |
|
|
Note: Drives Supported (maximum) is based on use of Compaq StorageWorks
Enclosure 4200/4300 family (14 hard disk drive enclosure). |
|
|
Cache |
16-MB cache engine |
|
|
RAID Support |
0, 1, 0+1 5 |
|
|
Logical Drives (maximum) |
32 |
|
|
Online Configuration |
Yes |
|
|
Online Capacity Expansion |
Yes |
|
|
Logical Drive Capacity
Extension |
Yes |
|
|
Online Stripe Size Migration |
Yes |
|
|
Online RAID Level Migration |
Yes |
|
|
Online Spare Support |
Yes |
|
|
Automatic Data Recovery |
Yes |
|
|
Drive Roaming |
Yes |
|
|
Redundant
Controllers |
No |
|
|
|
|
| Smart Array 4200
Controller |
|
Data Compatible with all Smart
Array Controllers |
Yes |
|
Instant Upgrades to other
Smart Array Controllers |
Yes |
|
Consistent Software
Manageability Tools |
Yes |
|
|
PCI Bus |
64-bit, 33 MHz |
|
|
PCI Peak Data Transfer Rate |
266 MB/s |
|
|
SCSI Protocols Supported |
Ultra2, Wide-Ultra |
|
|
SCSI Peak Data Transfer Rate |
320 MB/s total, 80 MB/s per
channel |
|
|
Channels |
4 |
|
|
SCSI Ports (external/internal) |
4/2 |
|
|
Drives Supported (maximum) |
56 |
|
|
Note: Drives Supported (maximum) is based on use of Compaq StorageWorks
Enclosure 4200/4300 family (14 hard disk drive enclosure). |
|
|
Cache |
64-MB battery backed read-write |
|
|
RAID Support |
0, 1, 0+1, 5 |
|
|
Logical Drives (maximum) |
32 |
|
|
Online Configuration |
Yes |
|
|
Online Capacity Expansion |
Yes |
|
|
Logical Drive Capacity
Extension |
Yes |
|
|
Online Stripe Size Migration |
Yes |
|
|
Online RAID Level Migration |
Yes |
|
|
Online Spare Support |
Yes |
|
|
Automatic Data Recovery |
Yes |
|
|
Drive Roaming |
Yes |
|
|
Redundant
Controllers |
No |
|
|
|
|
| Smart Array 5300
Controller |
|
Data Compatible with all Smart
Array Controllers |
Yes |
|
Instant Upgrades to other
Smart Array Controllers |
Yes |
|
Consistent Software
Manageability Tools |
Yes |
|
|
PCI Bus |
64-bit, 66MHz |
|
|
PCI Peak Data Transfer Rate |
533 MB/s |
|
|
SCSI Protocols Supported |
Ultra3, Ultra2, Wide-Ultra |
|
|
SCSI Peak Data Transfer Rate |
640 MB/s total, 160 MB/s per
channel |
|
|
Channels |
2, 4 |
|
|
SCSI Ports (external/internal) |
2 channel model: 2/2
4 channel model: 4/2 |
|
|
Drives Supported (maximum) |
56 |
|
|
Note: Drives Supported (maximum) is based on use of Compaq StorageWorks
Enclosure 4200 family. (14 hard disk drive enclosure) |
|
|
Cache |
128, 64 or 32 MB battery backed
read-write |
|
|
RAID Support |
0, 1, 0+1, 5, Advanced Data
Guarding |
|
|
Note: RAID ADG will be available as of Q4 2000. For customers who have
purchased the SA-5304/128 a quick firmware upgrades to enable the technology will be
available from www.compaq.com/smartarray.
The 128-MB cache module with RAID ADG will also be available as of Q4 2000. |
|
|
Note: RAID Support: Advanced Data Guarding (RAID ADG) is available with
128-MB versions of the SA-5300 only. |
|
|
Logical Drives (maximum) |
32 |
|
|
Online Configuration |
Yes |
|
|
Online Capacity Expansion |
Yes |
|
|
Logical Drive Capacity
Extension |
Yes |
|
|
Online Stripe Size Migration |
Yes |
|
|
Online RAID Level Migration |
Yes |
|
|
Online Spare Support |
Yes |
|
|
Automatic Data Recovery |
Yes |
|
|
Drive Roaming |
Yes |
|
|
Redundant
Controllers |
No |
|
|
|
|
| 64-bit/66-MHz
Single Channel Wide Ultra3 SCSI Adapter |
|
Drives Supported
Storage Capacity
Data Transfer Method
Maximum SCSI Channel Transfer Rate |
Up to 14 SCSI devices
254.8 GB
64-bit/66-MHz PCI bus-master
160 MB/s per channel |
|
Maximum Transfer Rate per PCI
Bus (peak) |
532 MB/s per channel |
|
SCSI Protocols |
Wide Ultra3 SCSI
Wide Ultra2 SCSI
Wide-Ultra SCSI-3
Fast-Wide SCSI-2
Fast SCSI-2 |
|
|
Electrical Protocol |
Low Voltage Differential (LVD) |
|
|
SCSI Termination |
Active Termination |
|
|
External SCSI Connectors |
One 68-Pin Wide Ultra SCSI-3
connector |
|
|
Internal SCSI Connectors |
Two 68-Pin Wide Ultra SCSI-3
connectors (one LVD and one SE)
One 50-Pin Narrow Ultra connector |
|
|
|
|
| 64-bit/66-MHz Dual
Channel Wide Ultra3 SCSI Adapter |
|
Drives Supported
Storage Capacity
Data Transfer Method
Maximum SCSI Channel Transfer Rate |
Up to 28 SCSI devices (14 per
channel)
1.019 TB
64-bit/66-MHz PCI bus-master
160 MB/s per channel |
|
Maximum Transfer Rate per PCI
Bus (peak) |
532 MB/s per channel |
|
SCSI Protocols |
Wide Ultra3 SCSI
Wide Ultra2 SCSI
Wide-Ultra SCSI-3
Fast SCSI-2 |
|
|
Electrical Protocol |
Low Voltage Differential (LVD) |
|
|
SCSI Termination |
Active Termination |
|
|
External SCSI Connectors |
Two 68-Pin VHDCI connectors |
|
|
Internal SCSI Connectors |
Two 68-Pin Wide Ultra SCSI-3
connectors
One 50-Pin Narrow Ultra connector |
|
|
|
|
| Compaq NC3131 Fast
Ethernet NIC 64 PCI Dual Port 10/100 |
Network Interface |
10Base-T/100Base-TX |
|
|
|
|
| Compatibility |
IEEE 802.3/802.3u compliant |
|
|
|
|
|
|
Data Transfer Method |
32/64-bit bus-master PCI |
|
|
|
|
|
|
Network Transfer Rate |
10Base-T (Half-Duplex), 10Base-2 |
10 Mb/s |
|
|
10Base-T (Full-Duplex) |
20 Mb/s |
|
|
100Base-TX (Half-Duplex) |
100 Mb/s |
|
|
100Base-TX (Full-Duplex) |
200 Mb/s |
|
|
|
|
|
Connector |
Dual RJ-45 |
|
|
|
|
|
|
I/O Address and Interrupt |
Automatic Configuration |
|
|
|
|
|
|
Cable Support |
10Base-T100Base-TX |
Categories 3, 4 or 5 UTP (2 or 4
pair); up to 328 feet (100 meters) Category 5 UTP (2 pair); up to 328 feet (100 meters) |
|
|
|
|
Compaq Rack 9142
(42U)(optional) |
|
Dimensions Height |
Total Cabinet
78.7 in/
2,000 mm |
Shipping 83.38 in/
2,168.65 mm |
Color |
|
Depth |
35.8 in/
909 mm |
48 in/
121.92 mm |
Opal |
|
Width |
23.7 in/
603 mm |
32 in/
812.8 mm |
|
|
|
Weight |
253 lbs/
114.84 kg |
325 lbs/
147.52 kg |
|
|
|
|
|
Compaq Rack 9136
(36U)(optional) |
|
Dimensions Height |
Total Cabinet
68.6 in/
1,742 mm |
Shipping
75.25 in/
1,911.35 mm |
Color |
|
Depth |
35.8 in/
909 mm |
48 in/
121.92 mm |
Opal |
|
Width |
23.7 in/
603 mm |
32 in/
812.8 mm |
|
|
|
Weight |
165 lbs/
75 kg |
234 lbs/
106 kg |
|
|
|
|
|
| Compaq Rack 9122 (22U)(optional) |
|
Dimensions
Height |
Total Cabinet
43 in/
1,092 mm |
Shipping
52.25 in/
1,327.15 mm |
Color |
|
Depth |
35.8 in/
909 mm |
48 in/
121.92 mm |
Opal |
|
Width |
24 in/
610 mm |
32 in/
812.8 mm |
|
|
|
Weight |
176 lbs/
79.89 kg |
225 lbs/
102.13 kg |
|
|
|
|
|
|