|
|
|
Options
| Step
2 - Mandatory Options |
| Step 2c - Ethernet Adapters |
- Selection of Ethernet adapter is mandatory
|
| Ethernet adapter is not required if KZPCM is selected as the SCSI adapter.
|
| PCI 1-port 32-bit 10/100-Mb
single-channel UTP FE Ethernet adapter (Twisted Pair); maximum 2 per system |
3X-DE600-AA |
| PCI 2-port 32/64-bit 10/100-Mb
UTP FE Ethernet adapter (Twisted Pair); maximum 2 per system |
3X-DE602-AA |
| SC-SC dual Fibre Optic cable, mm,
pp xx = length in meters |
BN34B-xx |
|
| Step
3 - Additional CPU Modules - Optional |
- Systems support one additional CPU module
|
| Tru64 UNIX SMP upgrade with one
6/500 CPU and Tru64 UNIX SMP license |
KN310-AB |
| OpenVMS SMP upgrade with one
6/500 CPU and OpenVMS SMP license |
KN310-AC |
|
| Step
4 - Memory - Optional |
- System supports four memory kits (each kit includes four industry-standard ECC DIMMs) - one kit included
|
- Maximum 4-GB memory per system
|
| 1-GB (4 x 256-MB DIMMs) memory
kit |
MS340-EA |
| 512-MB (4 x 128-MB DIMMs) memory
kit |
MS340-DA |
| 256-MB (4 x 64-MB DIMMs) memory
kit |
MS340-CA |
|
| Step
5 - Internal Storage - Optional |
Pedestal enclosure
supports 10 storage devices:
- One dedicated 1.44-MB diskette drive slot (included)
- Two 5.25² removable media slots (600-MB 32X CD-ROM drive
included in one slot)
- Seven 3.5² internal hard disk drive slots
|
|
| Step 5a - Internal Storage Disk Drives |
- Selection of one system disk drive is mandatory; six additional disk drives are
supported in internal storage disk shelf.
|
- Internal storage disk shelf is configured in single-bus mode; to configure internal
storage disk shelf in split-bus mode, one additional SCSI port and one H8253-AA UltraSCSI
bus splitter kit are required.
|
- KZPAC RAID Array 230/Plus controller supports 9.1-GB drives.
|
- 18.2-GB or higher disk drives not supported with KZPAC-xx RAID controllers
|
| 36.4-GB 7200 rpm UltraSCSI drive |
DS-RZ1FB-VW |
| 18.2-GB 10,000 rpm UltraSCSI |
DS-RZ1ED-VW |
| 18.2-GB 7200 rpm UltraSCSI drive |
DS-RZ1EA-VW |
| 9.1-GB 10,000 rpm UltraSCSI drive |
DS-RZ1DD-VW |
| 9.1-GB 7200 rpm UltraSCSI drive |
DS-RZ1DA-VW |
|
| Step 5b - Internal UltraSCSI Cable Kit |
| UltraSCSI bus splitter kit with
SCSI bus repeater card, two data cables, Y power cable harness, SCSI active terminator
assembly, and installation guide; required to configure internal storage shelf in
split-bus mode |
H8253-AA |
|
| Step 5c - Internal Removable Media Devices |
- System includes CD-ROM drive in 5.25² half-height removable
media slot
|
- System supports one additional 5.25² half-height removable
media device
|
| 600-MB 5.25²
32X CD-ROM drive (RRD47), top gun blue |
RRD47-VD |
| 12/24-GB 4 mm 5.25² DAT SCSI tape drive (TLZ10), top gun blue |
TLZ10-LB |
|
| Step
6 - Storage Adapters/Controllers - Optional |
- Storage controllers require Tru64 UNIX V4.0E or OpenVMS V7.1-2
|
| UltraSCSI Adapters
|
| PCI 2-port UltraSCSI single-ended
and 10/100 Mb Ethernet combo adapter (uses one PCI slot) includes internal 68-pin and
50-pin HD connectors and two external 68-pin VHDCI SCSI connectors, requires BN37A cable
(0.3- to 20-m) to connect to UltraSCSI shelf; maximum four per system |
KZPCM-DA |
VHDCI male-to-VHDCI male
UltraSCSI cable; required for each external UltraSCSI shelf attached to KZPCM; xx = 0C
[0.3m], 0E [0.5m], 01 [1.0m], 1E [1.5m], 02 [2.0m], 2E [2.5m],
03, 05, 10, 15, 20, 25 m |
BN37A-xx |
|
| PCI 1-port UltraSCSI single-ended
adapter (uses one PCI slot); includes internal 68-pin and 50-pin HD connectors and
external 68-pin HD connector, requires BN38C cable (2 to 20 m) to connect to UltraSCSI
shelf, maximum four per system. |
KZPBA-CA |
| PCI 1-port UltraSCSI differential
adapter, (uses one PCI slot); includes external 68-pin HD connector, requires BN38C cable
(2 to 25 m) to connect to differential UltraSCSI shelf or external RAID array controller,
maximum four per system. |
KZPBA-CB |
| 68-pin HD male-to-VHDCI male
UltraSCSI cable; xx = 02, 03, 05, 10, 20, 25 m |
BN38C-xx |
|
| UltraSCSI RAID
Controllers |
- Maximum four KZPAC-xx controllers per system
|
| PCI 1-port UltraSCSI RAID
controller with 4-MB cache memory, includes RAID Array 230/Plus Subsystem software and
documentation kit and VHDCI female connector; tape drives not supported, maximum four per
Tru64 UNIX systems, maximum three per OpenVMS systems- 18.2-GB
or higher disk drives not supported on KZPAC-xx RAID controllers; requires BN37A cable
(0.3 to 20 m) to connect to UltraSCSI shelf |
KZPAC-AA |
| PCI 3-port UltraSCSI RAID
controller with 4-MB cache memory, includes RAID Array 230/Plus Subsystem Software and
documentation kit; tape drives not supported; SCSI cable required for each active port;
requires BN31K-0E for external third-port connection, maximum three per system; requires
BN37A cable (0.3 to 20 m) to connect to UltraSCSI shelf |
KZPAC-CA |
| Same as KZPAC-CA with 8-MB cache
memory |
KZPAC-CB |
| Cache battery backup for KZPAC
controller |
KZPSC-UB |
VHDCI male-to-VHDCI male
UltraSCSI cable; xx = 02, 2E [2.5], 03, 05, 10, 20 m
Note: Manufacturing may substitute BN37A-02 cable for certain cabinet
configurations. |
BN37A-xx |
| SCSI cable/bulkhead assembly kit
with KZPAC-CA/CB, allows external connection of one third port |
BN31K-0E |
| SCSI cable/bulkhead assembly kit
with two ports for KZPAC-CA/CB, allows external connection of two third ports |
KZPAC-SB |
|
| Fibre Channel
Controller |
| Fibre Channel External RAID
controller (Tru64 UNIX only); maximum four per system |
KGPSA-BC |
| 8-port optional Fibre Channel
switch |
DS-DSGGA-AA |
| 16-port optional Fibre Channel
switch |
DS-DSGGA-AB |
|
| CI Adapter |
| PCI CI adapter (OpenVMS systems
only); requires two PCI slots and CI cable for each adapter, maximum one per system |
CIPCA-BA |
| CI cable |
BNCIA-xx |
|
| Step
7 - Storage Devices - Optional |
| UltraSCSI
Configuration Rules |
- UltraSCSI configurations require UltraSCSI components (controllers, adapters, shelves,
disks, and cables).
|
- UltraSCSI adapters and RAID controllers support UltraSCSI disks at UltraSCSI speeds in
UltraSCSI top gun blue shelves (DS-BA356-xx).
|
- Fast10 BA356-xx SCSI shelves cannot be retrofitted; replace Fast10 SCSI shelf with
DS-BA356-xx shelf when adding an UltraSCSI disk and when connecting to UltraSCSI adapter.
|
- UltraSCSI and Fast10 drives can be mixed in DS-BA356 top gun blue UltraSCSI shelf;
UltraSCSI adapter negotiates maximum transfer speed of drives.
|
|
| UltraSCSI
StorageWorks Shelves |
- UltraSCSI top gun blue shelf provides support for UltraSCSI disk drives. The shelf is
available in single-bus or split-bus configurations, and the shelf includes personality
module and 180W power supply.
|
- UltraSCSI shelf supports seven 3.5² hard disk drives, or one
5.25² device and four 3.5² hard
disk drives, or two 5.25² devices and one 3.5² hard disk drive
|
- Installation of redundant power supply reduces number of 3.5²
drive slots by one.
|
|
| UltraSCSI Pedestal
Enclosure |
| UltraSCSI single-ended pedestal,
single-bus personality module, 180W power supply, U.S. power cord |
DS-BA356-KF |
| UltraSCSI single-ended pedestal,
split-bus personality module, 180W power supply, U.S. power cord |
DS-BA356-KG |
| UltraSCSI pedestal, differential
personality module, 180W power supply, U.S. power cord (non-U.S./Canada require
country-specific power cords) |
DS-BA356-KH |
| 180W power supply, requires
country-specific power cord |
DS-BA35X-HH |
|
| Tabletop Tape
Drives |
- Tape drives require dedicated KZPBA-CA UltraSCSI adapter, BN21K-xx SCSI cable, and
country-specific power cord.
|
| 12/24-GB 4 mm DAT narrow
single-ended tabletop SCSI tape, includes 120V North American power cord, and requires
BN31W-xx SCSI cable |
DS-TLZ10-DB |
| 35/70-GB DLT single-ended
tabletop tape drive |
DS-TZ89N-TA |
| DLT mini-library single-ended
tabletop tape drive |
DS-TL891-NE |
| DLT mini-library 16-slot
expansion unit tabletop tape drive |
DS-TL890-NE |
|
| Step
8 - External CI Controllers - Optional |
- Supported in M-Series Cabinets
|
- Supported on OpenVMS systems only
|
- Require CIPCA-BA storage controller and cables
|
- QB-5C4AA-SA software kit required per external cache (for example, one per HSJ50, two
per HSJ52)
|
| StorageWorks 6-channel CI Array
controller with 32-MB write-back cache and external cache battery |
HSJ50-AF |
| Same as above with 64-MB
write-back cache and external cache battery |
HSJ50-AH |
| Same as above with 128-MB
write-back cache and external cache battery |
HSJ50-AJ |
| StorageWorks dual 6-channel CI
Array controller with 64-MB cache and dual external cache battery |
HSJ52-AF |
| Same as above with 128-MB cache
and dual external cache battery |
HSJ52-AH |
| Same as above with 256-MB cache
and dual external cache battery |
HSJ52-AJ |
| Same as above with 512-MB cache
and dual external cache battery |
HSJ54-AJ |
|
| Controller
Accessories |
| External SCSI 68-pin male 8-bit
or 16-bit differential terminator |
H879-AA |
| SCSI tri-link connector, 68-pin,
two female and one male connector |
H885-AA |
| SCSI Y cable 68-pin, two female
and one male connector |
BN21W-0B |
| Rackmount StorageWorks controller
shelf with RETMA mounting kit, and 180 W NEMA power for H9A10-MC/ H9A15-MC Cabinet,
Americas, Asia Pacific- order BN30B-02 for mounting in
H9A10-MD/ H9A15-MD cabinet, Europe |
BA35R-MR |
| IEC-to-IEC gray power cord for
BA35R-MR self mounted in H9A1x-MD Cabinet, Europe |
BN30B-02 |
| IEC-to-IEC black power cord for
BA35R-MR shelf mounted in H9A1x-MD Cabinet, Europe |
BN35S-02 |
| Power supply for N+1 redundant
support in UltraSCSI StorageWorks controller shelf and power cords |
CK-BA35X-HH |
| Star Coupler Passive Hub device,
supports eight CI ports |
SC008-AC |
| Star Coupler Passive Hub
expansion device, supports eight CI ports (supported in SC008-AC) |
SC008-AD |
|
| Step
9 - UltraSCSI RAID Array Controllers and UltraSCSI RAID
Packaged Solutions - Optional |
| RAID Array 3000
Rackmount Controller Shelf |
- RA3000 is currently supported on Tru64 UNIX V4.0D or higher; selection of RA3000
Solutions Software Kit
is required.
|
- Supported SCSI adapter- KZPBA-CB PCI 1-port UltraSCSI
differential adapter
|
RA3000 rackmount controller
shelf, blue, with one controller, 110V
Includes: UltraSCSI BA356 controller shelf, one HSZ22 2-channel controller with 16-MB
cache, integrated Environmental Monitoring Unit (EMU), two 180W power supplies, two
dual-port host differential UltraSCSI I/O SBBs, dual-channel UltraSCSI single-ended
personality modules, one 120V 1000VA rackmount UPS, 5-m host SCSI cable (BN37A-05),
BN38E-0B adapter, UPS serial cable, PC connection serial cable (DB-9), two 68-pin HD
tri-link adapters (H8861-AA), two North American power cords, and RETMA mounting bracket
(disk shelves and disks not included)
Requires: Solutions Software Kit for platform, host adapter, RA3000 disk shelf, and disks
Options: Second HSZ22 controller, up to three additional RA3000 disk shelves, cache memory
upgrade |
DS-SWXRA-GH |
RA3000 rackmount controller
shelf, blue, with one controller, 230V
Includes: UltraSCSI BA356 controller shelf, one HSZ22 2-channel controller with 16-MB
cache, integrated Environmental Monitoring Unit (EMU), two 180W power supplies, two
dual-port host differential UltraSCSI I/O SBBs, dual-channel UltraSCSI single-ended
personality modules, one 230V 1000VA rackmount UPS, 5-m host SCSI cable (BN37A-05),
BN38E-0B adapter, UPS serial cable, PC connection serial cable (DB-9), two 68-pin HD
tri-link adapters (H8861-AA), RETMA mounting bracket (disk shelves and disks not included)
Requires: Solutions Software Kit for platform, two country-specific power cords,
host adapter, RA3000 disk shelf, and disks
Options: Second HSZ22 controller, up to three additional RA3000 disk shelves, cache
memory upgrade |
DS-SWXRA-GK |
|
| RAID Array 3000
Rackmount Disk Shelf |
- Select one to four disk shelves.
|
- Third and fourth DS-SWXRA-GN disk shelf ordered will be installed in rear of M-series
cabinet; rear mounted shelves require that a 2-m BN37A-02 SCSI cable be ordered.
|
| RA3000 rackmount disk shelf,
blue, includes UltraSCSI BA356 disk shelf, two 180 W power supplies, single-ended
UltraSCSI personality card, one half-meter SCSI cable (BN37A-0E), two North American power
cords, and RETMA mounting bracket (disks not included); order two country-specific power
cords for non-North American use |
DS-SWXRA-GN |
|
| HSZ22 Controller |
| Note: Second
HSZ22 controller ordered is field installable only, not factory installed; requires
BN37A-0E SCSI jumper cable be ordered separately. |
Second HSZ22 controller with
16-MB cache and two 16-MB SIMMs for mirror cache, one BN37A-05 5-m UltraSCSI cable, one
BN38E-0B cable adapterfield installable only.
Note: Second HSZ22 controller does not require additional Solution Software Kit. |
DS-HSZ22-AA |
| RA3000 16-MB SIMM cache memory
upgrade, field-installed only |
DS-HSSIM-BA |
| RA3000 32-MB SIMM cache memory
upgrade, field-installed only |
DS-HSSIM-BB |
|
| RA3000 Solutions
Software Kits |
- RA3000 Solutions Software Kits include: StorageWorks Command Console (SWCC) software,
platform-specific software, Installation scripts and installation documentation
|
| RA3000 Solutions Software Kit for
Tru64 UNIX |
QB-5TWAB-SA |
| RA3000 Solutions Software Kit for
OpenVMS |
QB-5TWAC-SA |
|
| HSG80/HSZ80
External Controllers |
- HSG80 supported externally; HSZ80 supported internally and externally
|
| Fibre Channel controller
(DS-HSG80-BJ), includes 2-MB cache expandable to 128 MB; requires 128697-B21 HSG80 ACS
V8.4F software kit or 128698-B21 V8.4P software kit for each HSG80 ordered |
380672-B21 |
| Fibre Channel controller
(DS-HSG80-BH), includes 2-MB cache expandable to 32 MB; requires 128697-B21 HSG80 ACS
V8.4F software kit or 128698-B21 V8.4P software kit for each HSG80 ordered |
380671-B21 |
| UltraSCSI controller
(DS-HSZ80-AH), includes 2-MB cache expandable to 32 MB; requires 400569-001 for Tru64 UNIX
or 400571-001 for OpenVMS |
400564-B21 |
| UltraSCSI controller
(DS-HSZ80-AJ), includes 2-MB cache expandable to 128 MB; requires 400569-001 for Tru64
UNIX or 400571-001 for OpenVMS |
400565-B21 |
|
| ESA 10000 , RAID
Array 7000, RAID Array 8000 |
- Enterprise Storage Array 10000 and RAID Array 7000 and 8000 (HSZ70 and HSZ80) product
sets are supported on AlphaServer DS20 systems
|
|
|
|
| Step
10 - Graphics Adapters - Recommended |
- Select graphics adapter, monitor, and country-specific keyboard for Tru64 UNIX and
OpenVMS systems, if required.
|
- RAID Configuration Utility is accessible via the console port for Tru64 UNIX and OpenVMS
systems; optional graphics capability is available.
|
- Tru64 UNIX systems support multi-head homogeneous graphics; a monitor is recommended for
each graphics adapter.
|
| PowerStorm 4D51T 3D Graphics, 16-
MB texture memory 1280 x 1024, High-Performance 3D shading, texture mapping, OpenGL, (when
using PowerStorm with the V500 monitor, use PowerStorm switch number two [1024x1280 at 60
Hz] to allow V500 to display UNIX screen completely)- maximum
three per Tru64 UNIX systems |
SN-PBXGI-AD |
| PowerStorm 300 PCI 15-MB Texture
memory/ 16-MB Frame buffer memory |
SN-PBXGD-AD |
| PowerStorm 350 PCI 30-MB Texture
memory/ 32-MB Frame buffer memory |
SN-PBXGD-AE |
| ELSA Gloria synergy graphics with
8-MB SGRAM 1600 x 1200, 2D/3D graphic accelerator; maximum three per Tru64 UNIX system and
one per OpenVMS system |
SN-PBXGK-BB |
|
| Step
11 - Monitors - Recommended |
- RAID Configuration Utility is accessible via the console port for Tru64 UNIX and OpenVMS
systems; optional graphics capability is available.
|
- Graphics monitors other than those listed below can be used if compatible with SVGA
graphics that are ordered with a system.
|
- Selection of video extension cable and country-specific power cord is mandatory for all
monitors.
|
15²
(13.8² viewable image size) Corporate Series auto-scan color
monitor, flat square Invar CRT,
0.28 mm dot pitch, VGA to 1024 x 768 at 85 Hz, TCO 95, MPRII, Energy Star, attached 1.8-m
video cable; requires video extension cable and country-specific power cord; Northern
Hemisphere without power cord |
3R-VRQV5-24 |
| Same as above except Southern
Hemisphere without power cord |
3R-VRQV5-11 |
17²
(16² viewable image size) professional series auto-scanning
color monitor, Trinitron CRT, 0.25 mm aperture grill pitch, VGA to 1280 x 1024 at 75 Hz,
TCO 95, MPR-II, Energy Star, attached
1.8-m video cable; requires video extension cable and country-specific power cord;
Northern Hemisphere without power cord |
3R-VRQP7-24 |
| Same as above except Southern
Hemisphere without power cord |
3R-VRQP7-23 |
21²
(19.6² viewable image size) auto-scanning color monitor,
Trinitron CRT, 0.25 mm aperture grill pitch, VGA to 1600 x 1200 at 75 Hz NI, TCO 95,
Energy Star, includes
1.8-m video cable; requires video extension cable and country-specific power cord;
Northern Hemisphere without power cord |
3R-VRQP1-24 |
| Same as above except Southern
Hemisphere without power cord |
3R-VRQP1-23 |
|
| Video Extension Cable |
|
| 1.8-m video extension cable |
BN39C-02 |
|
| Monitor Power Cords |
|
| North America, Japan |
BN26J-1K |
| UK/Ireland/Hong Kong |
BN19A-2E |
| Central Europe |
BN19C-2E |
| Switzerland |
BN19E-2E |
| Australia/New Zealand |
BN19H-2E |
| Denmark |
BN19K-2E |
| Israel |
BN18L-2E |
| Italy |
BN19M-2E |
| India/South Africa |
BN19S-2E |
| Japan |
3X-BN46F-02 |
|
| Step
12 - Networks and Communications - Optional |
- Controllers/adapters require a minimum of Tru64 UNIX V4.0E or OpenVMS V7.1-2
|
| PCI 10/100-Mb 1-port Fast
Ethernet controller (Twisted Pair); maximum two per system |
DE500-BA |
| PCI 10/100-Mb 4-port Fast
Ethernet controller (Twisted Pair); maximum one per system |
DE504-BA |
| Cable for 10BaseT Twisted Pair
connection |
BN25G-xx |
| PCI 10/100-Mb Fast Ethernet
controller (MMF); maximum two per system |
DE500-FA |
| PCI Gigabit Ethernet adapter, no
boot support, maximum two per Tru64 UNIX systems |
DEGPA-SA |
| SC-SC dual fibre optic cable, mm,
pp. |
BN34B-xx |
| PCI-to-ATM 155 Mb Fibre adapter
(Tru64 UNIX only); maximum four per system |
3X-DAPBA-FA |
| PCI-to-ATM 622 Mbit Fibre adapter
(Tru64 UNIX only); maximum two per system |
3X-DAPCA-FA |
| PCI FDDI adapter, single
attachment station (SAS), multi-mode fibre (MMF), SC connector, maximum two per system |
DEFPA-AB |
| PCI FDDI adapter, DAS, MMF, SC
connector, maximum two per system |
DEFPA-DB |
| MIC-SC dual fibre optic cable |
BN34D-xx |
| SC-to-SC dual fibre optic cable |
BN34B-xx |
| PCI FDDI adapter, SAS, TP-PMD,
requires BN25H-03; maximum two per system |
DEFPA-UB |
| PCI FDDI dual adapter, DAS,
TP-PMD, requires BN25H-03; maximum two per system |
DEFPA-MB |
| 9.8 ft (3-m) FDDI crossover cable |
BN25H-03 |
| PCI 4-port asynchronous
controller, cable included; maximum two per Tru64 UNIX system; maximum two PBXDA-xx per
system |
PBXDA-AA |
| PCI 8-port asynchronous
controller, cable included; maximum two per Tru64 UNIX system; maximum two PBXDA-xx per
system |
PBXDA-AB |
| PCI 16-port asynchronous
controller, cable included; maximum two per Tru64 UNIX systems, maximum two PBXDA-xx per
system |
PBXDA-AC |
|
| Step
13 - MEMORY CHANNEL - Optional |
- Supported on Tru64 UNIX systems only; requires Tru64 UNIX V4.0F with TruCluster V1.6 or
later
|
- Up to two PCI System Area Network controllers are supported with Console Firmware V5.5-x
or later
|
- Each system node in a MEMORY CHANNEL cluster requires a TruCuster Production Server
license
(QB-3RLAE-KA) or TruCluster MEMORY CHANNEL (QB-4ZCAE-AA) software license.
|
- TruCluster MEMORY CHANNEL license (QB-4ZCAE-AA), normally used for high- performance
technical computing applications, is not required if systems include TruCluster Production
Server license (QB-3RLAE-KA).
|
|
| MEMORY CHANNEL
Controller/Hub |
| PCI System Area Network
controller, maximum two |
CCMAB-AA |
| System Area Network hub with four
line cards; includes BN19P-2E power cord for Canada/US operations; country-specific power
cord for other regions is required; maximum two |
CCMHB-AA |
| MEMORY CHANNEL hub expansion box
with no line cards; maximum two |
CCMHB-BA |
| Expansion line card for CCMHB
hub; maximum two |
CCMLB-AA |
| 1-m cable for CCMAB and CCMHB |
BN39B-01 |
| 4-m cable for CCMAB and CCMHB |
BN39B-04 |
| 10-m cable for CCMAB and CCMHB |
BN39B-10 |
| TruCluster Production Server
Software for Tru64 UNIX |
QB-3RLAE-AA |
| Tru64 UNIX Driver for MEMORY
CHANNEL license |
QB-4ZCAE-AA |
|
| MEMORY CHANNEL
Power Cords |
| Ireland, United Kingdom |
BN19A-2E |
| Egypt, India |
BN19S-2E |
| Central Europe |
BN19C-2E |
| Israel |
BN18L-2E |
| Switzerland |
BN19E-2E |
| Italy |
BN19M-2E |
| Denmark |
BN19K-2E |
| Australia, New Zealand |
BN19H-2E |
| Japan |
3X-BN46F-02 |
|
| Step
14 - Additional Power Supply - Optional |
- One additional power supply can be added to DS20 Pedestal system for N+1 redundancy.
Redundant power supply requires country-specific power cord.
|
| 675W redundant power supply,
requires country-specific 4.5-m rackmount power cord |
H7899-AA |
|
| Step
15 - Keyboards, Power Cords, Documentation |
- Systems ordered in North America include U.S. English keyboard; selection of
country-specific keyboard is mandatory for all non-North American systems.
|
| Keyboards |
| |
Tru64 UNIX |
OpenVMS |
| U.S./English keyboard |
SN-LKQ47-AA |
LK461-A2 |
| Belgian keyboard |
SN-LKQ47-AB |
LK461-AB |
| Canadian/French keyboard |
SN-LKQ47-AC |
LK461-AC |
| Danish keyboard |
SN-LKQ47-AD |
LK461-AD |
| UK keyboard |
SN-LKQ47-AE |
- |
| Finnish keyboard |
SN-LKQ47-AF |
LK461-AF |
| German keyboard |
SN-LKQ47-AG |
LK461-AG |
| Dutch keyboard |
SN-LKQ47-AH |
LK461-AH |
| Italian keyboard |
SN-LKQ47-AI |
LK461-AI |
| Swiss/French keyboard |
SN-LKQ47-AK |
LK461-AK |
| Swiss/German keyboard |
- |
LK461-AL |
| Swedish keyboard |
SN-LKQ47-AM |
LK461-AM |
| Norwegian keyboard |
SN-LKQ47-AN |
LK461-AN |
| French keyboard |
SN-LKQ47-AP |
LK461-AP |
| Canadian/English keyboard |
- |
LK461-AQ |
| Latin-American keyboard |
SN-LKQ47-AR |
- |
| Spanish keyboard |
SN-LKQ47-AS |
LK461-AS |
| Hebrew keyboard |
SN-LKQ47-AT |
LK461-AT |
| Portuguese keyboard |
SN-LKQ47-AV |
LK461-AV |
| BHCSY keyboard |
SN-LKQ47-AX |
- |
| International keyboard |
SN-LKQ47-BA |
- |
| Greek keyboard |
SN-LKQ47-BH |
LK461-BH |
| Taiwanese keyboard |
SN-LKQ47-BI |
- |
| Korean keyboard |
SN-LKQ47-BK |
- |
| Romanian keyboard |
- |
LK461-BL |
| Polish keyboard |
SN-LKQ47-BP |
LK461-BP |
| Hungarian keyboard |
SN-LKQ47-BQ |
LK461-BQ |
| Arabic keyboard |
SN-LKQ47-BR |
- |
| Cyrillic keyboard |
SN-LKQ47-BT |
LK461-BT |
| Turkish keyboard |
SN-LKQ47-BU |
LK461-BU |
| Czech keyboard |
SN-LKQ47-BV |
LK461-BV |
| Turkish/French keyboard |
- |
LK461-BW |
| Yugoslavian keyboard |
- |
LK461-BY |
| Thai keyboard |
SN-LKQ47-CB |
- |
| S. Chinese keyboard |
SN-LKQ47-CV |
- |
| Slovak keyboard |
SN-LKQ47-CZ |
LK461-CZ |
|
| Pedestal Power
Cords |
- Systems ordered in North America include BN26J-1K 120V North American power cord; order
country-specific power cord for all non-North American systems and for redundant system
power supplies.
|
| North American 120V, 75² |
BN26J-1K |
| Australia, New Zealand, 2.5m |
BN19H-2E |
| Central Europe, 2.5m |
BN19C-2E |
| UK, Ireland, 2.5m |
BN19A-2E |
| Switzerland, 2.5m |
BN19E-2E |
| Denmark, 2.5m |
BN19K-2E |
| Italy, 2.5m |
BN19M-2E |
| Egypt, India, South Africa, 2.5m |
BN19S-2E |
| Israel, 2.5m |
BN18L-2E |
| Japan, 2.5m |
3X-BN46F-02 |
|
| Rackmount Power
Cords |
- Each system installed in a cabinet requires a Rackmount Kit (2T-R1200-AB) and one 4.5-m
power cord for each power supply ordered with the system.
|
| 4.5-m power cord - North American |
BN20Z-4E |
| 4.5-m power cord - non-North American |
BN35S-4E |
|
| Documentation |
| Additional AlphaServer DS20 User
Guide (print and CD), Installation Card, and Release Notes |
QZ-014AA-GZ |
|
| Step 16 - Printers - Optional |
- Systems include two full-duplex asynchronous serial ports and one bi-directional
enhanced parallel port.
|
- Asynchronous serial ports have 9-pin D-subminiature connectors; 9-pin to MMJ adapter
(H8571-J) is required for each connection.
|
|
| Step
17 - Console Terminal - Optional |
- RAID Configuration Utility is accessible via the console port for Tru64 UNIX and OpenVMS
systems.
|
- Console terminal with EIA-232 25-pin DSUB connector is required, unless otherwise
available.
|
- Shielded console cable (BC16E-25) is required for console terminal, unless available
on-site.
|
| VT510 terminal |
VT510-xx |
| Shielded console cable with
six-pin MMJ connectors |
BC16E-25 |
|
| Step 18 - M-series Cabinet Enclosures - Mounting
kit required for each system installed in M-Series Cabinet |
|
|
- M-series enclosure for DS20 requires the mandatory selection of the following items:
|
|
- H9A10 or H9A15 cabinet, 120V or 240V |
|
- Rack kit for each system |
|
- 4-5-m power cord per system |
|
- Cabinet front door based on cabinet height |
|
- Factory integration |
|
- Ballast kit as required |
|
| Cabinet Configuration Chart
for AlphaServer DS20 (11U) with StorageWorks Shelves (4U) |
| Cabinet |
Mounting Kit |
Cabinet Height/Space |
Systems |
Shelves |
Ballast Kit |
| H9A10-MC/MD |
2T-R1200-AB |
54.2²
/ 31U |
1
2 |
6
2 |
1
1 |
| H9A15-MC/MD |
2T-R1200-AB |
66.5²
/ 38U |
1
2
3 |
6
6
2 |
2
1 |
|
| Cabinet Configuration Chart for
AlphaServer DS20 (11U) with StorageWorks RA3000 and Disk Shelves (12U) |
- 12U of vertical cabinet space is reserved for one RA3000 controller shelf and up to five
disk shelves mounted in top of cabinet, front to back; an additional 2U of vertical space
is required for RA3000 controller shelf UPS.
|
- Disk shelves can be a combination of RA3000 DS-SWXRA-GN disk shelves and StorageWorks
BA36R-RC/RD disk shelves. Maximum five device shelves - one to
four RA3000 device shelves plus up to four StorageWorks BA36R-RC/RD device shelves.
|
- RA3000 controller shelf supports a maximum of four DS-SWXRA-GN disk shelves.
The third and fourth DS-SWXRA-GN disk shelf ordered will be installed in rear of an
M-series cabinet; rear mounted shelves require a 2-m SCSI cable (BN37A-02) be ordered
separately.
|
- Systems are supported in remaining vertical space.
|
|
| Cabinet |
Mounting Kit |
Cabinet Height / Space |
Systems |
RA3000 + Shelves |
Ballast Kit |
| H9A10-MC/MD |
2T-R1200-AB |
54.2²
/ 31U |
1 |
1 + 5 |
1 |
| H9A15-MC/MD |
2T-R1200-AB |
66.5²
/ 38U |
1
2 |
1 + 5
1 + 5 |
2
1 |
|
| Cabinet Configuration Chart for
AlphaServer DS20 (11U) with StorageWorks BA370 (20U) and Disk Shelves |
- 20U of vertical cabinet space is reserved for one front mounted BA370 rackmount
enclosure or one front mounted and one rear mounted BA370 enclosure in top of cabinet,
front to back.
Note: Top fan (1U) is removed from cabinet when BA370 rackmount enclosure is
installed.
|
- Rear cabinet extender is mandatory when second BA370 is ordered.
|
- Select H9C10-TE rear cabinet extender for H9A10 or H9C15-TE rear cabinet extender for
H9A15 Cabinet
|
- Systems and StorageWorks shelves are supported in remaining vertical space; StorageWorks
shelves are not supported in rear of cabinet behind front mounted BA370 rackmount
enclosure.
|
|
| Cabinet |
Mounting Kit |
Cabinet Height / Space |
Systems |
BA370 |
Shelves |
| H9A10-MC/MD |
2T-R1200-AB |
54.2²
/ 31U |
1
1 |
1 front BA370, or
2 front & back BA370s |
- |
| H9A15-MC/MD |
2T-R1200-AB |
66.5²
/ 38U |
1
1 |
1 front BA370, or
2 front & back BA370s |
4
4 |
|
| Cabinet
Enclosures |
| 67²
cabinet enclosure with 31U or 54.2² of usable vertical space;
120V dual-24A controller each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P,
Americas, Asia Pacific; includes rear door, top fan tray, and two H7600-AA power
distribution units |
H9A10-MC |
| 67²
cabinet enclosure with 31U or 54.2² of usable vertical space;
240V dual-16A controller, each with 12 IEC C13 outlets, input power plug IEC 309, 16A,
Europe; includes rear door, top fan tray, and two H7600-DB power distribution units |
H9A10-MD |
| 79²
cabinet enclosure with 38U or 66.5² of usable vertical space;
120V dual-24A controller, each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P,
Americas, Asia Pacific; includes rear door, top fan tray, and two H7600-AA power
distribution units |
H9A15-MC |
| 79²
cabinet enclosure with 38U or 66.5² of usable vertical space;
240V dual-16A controller, each with 12 IEC C13 outlets, input power plug IEC 309, 16A,
Europe; includes rear door, top fan tray, and two H7600-DB power distribution units |
H9A15-MD |
|
| Rackmount Kit |
| Rackmount Kit includes mounting
shelf, slide rails, front dress bezel, interlock mechanism, and cable management bracket - system slides out front of cabinet for full service access; each
system installed in cabinet requires one 4.5-m power cord for each power supply ordered
with system |
2T-R1200-AB |
| 4.5-m power cord - North American |
BN20Z-4E |
| 4.5-m power cord - non-North American |
BN35S-4E |
|
| Cabinet Front Door |
| Front door, top gun blue, for
H9A10-MC/MD Cabinet Enclosure |
H9C10-TF |
| Front door, top gun blue, for
H9A15-MC/ MD Cabinet Enclosure |
H9C15-TF |
|
| BA370 Rackmount
Enclosure/Rear Cabinet Extender |
| Rear Cabinet Extender
is mandatory when a second BA370 is ordered for H9A10 or H9A15 M-series Cabinets; Rear
Cabinet Extender provides 5.5² of depth to H9A10 or H9A15
cabinets to allow two BA370 enclosures to be installed front to back in cabinet. |
| BA370 front-mount rackmount
enclosure includes RETMA rackmount kit; first BA370 enclosure must be front mounted in
cabinet, 20U height. |
2T-BA370-AS |
BA370 rear-mount rackmount
enclosure includes RETMA rackmount kit; second BA370 enclosure must be rear mounted in
cabinet, 20U height.
Note: Rear Cabinet Extender, H9C10-TE or H9C15-TE, is mandatory for second BA370. |
2T-BA370-AR |
| Rear cabinet extender, top gun
blue, for H9A10-MC/MD cabinets |
H9C10-TE |
| Rear cabinet extender, top gun
blue, for H9A15-MC/MD cabinets |
H9C15-TE |
|
| Factory
Integration |
| Factory Integration of systems
and storage devices assembled and configured in cabinet enclosure in predefined locations |
YS-ASCAA-AA |
|
| Ballast Kit |
| Ballast is added to a
cabinet at exact locations for specific configurations to meet safety regulations for
installation, operation, and service; it is required in H9A15 cabinets when only one
system is installed. (See Cabinet Configuration charts.) |
| Two 35 to 40 lb steel plates |
H9C10-MC |
|
| Shelves supported
in M-Series Cabinets |
| UltraSCSI RETMA rack,
single-ended, single-bus personality module, 180W power supply, U.S. power cord |
BA36R-RC |
| UltraSCSI RETMA rack,
single-ended split-bus personality module, 180W power supply, U.S. power cord |
BA36R-RD |
Rackmount StorageWorks controller
shelf with RETMA mounting kit and NEMA power for H9A10-MC/
H9A15-MC cabinets, North America, Asia Pacific; order BN30B-02 for mounting in
H9A10-MD/H9A15-MD cabinet (Europe) |
BA35R-MR |
| 180W power supply, includes 120V
North American and 240V IEC power cord |
CK-BA35X-HH |
|
| Shelves supported
in SW8xx and SW5xx Cabinets |
| UltraSCSI Metric rack,
single-ended, single-bus personality module, 180W power supply |
DS-BA356-JD |
| UltraSCSI Metric rack,
single-ended split-bus personality module, 180W power supply |
DS-BA356-JE |
| UltraSCSI Metric rack,
single-ended, single-bus, differential personality module, 180W power supply |
DS-BA356-JF |
|
| Removable Media
Devices StorageWorks Shelves |
| 8-GB 4 mm DAT 93 MB/min
(compressed) narrow SCSI tape drive in StorageWorks carrier |
TLZ09-VA |
| 12/24-GB 4 mm DAT narrow SCSI
tape drive in StorageWorks carrier |
DS-TLZ10-VA |
| 32-64-GB 4 mm DAT SCSI tape drive
loader in full-height StorageWorks carrier |
TLZ9L-VA |
| 600-MB 32X CD-ROM drive in
StorageWorks carrier |
DS-RRD47-VA |
|
| StorageWorks Power
Supply |
| 180W power supply; requires
country-specific power cord |
DS-BA35X-HH |
|
| Compaq CustomSystems
Support |
| Cabinets containing
systems and storage must be assembled by qualified assemblers: Compaq Manufacturing,
Compaq CustomSystems Group, or authorized Compaq Certified Integration Partner. For
custom integration of systems, options, cabinet expansion offerings, and additional Compaq
and third-party devices, or for other cabinets, doors, and trim kits of a different color,
contact Compaq CustomSystems at 1-800-AT COMPAQ, or your local authorized Compaq
Certified Integration Partner. |
|
| Step
19 - Software - Required selection
of media and documentation for first system on site |
- Software Processor Code = E
|
| Tru64 UNIX |
- Tru64 UNIX systems include Traditional Unlimited User License, Server Extension, Open
Source Internet Solutions, and Netscape Enterprise Server 3.0.
|
| Tru64 UNIX media and online
documentation on CD-ROM |
QA-MT4AA-H8 |
| Tru64 UNIX full hard copy
documentation |
QA-MT4AA-GZ |
| StorageWorks Software Package
with licenses for Logical Storage Manager and AdvFS Utilities |
QB-5RXAE-AA |
| TruCluster Available Server
license |
QL-05SAE-AA |
| Advanced Server for Tru64 UNIX,
25 Client Concurrent License |
QL-5U29M-3D |
| Advanced Server for Tru64 UNIX,
50 Client Concurrent License |
QL-5U29M-3E |
| Advanced Server for Tru64 UNIX,
100 Client Concurrent License |
QL-5U29M-3F |
| Advanced Server for Tru64 UNIX,
250 Client Concurrent License |
QL-5U29M-3G |
| Advanced Server for Tru64 UNIX,
500 Client Concurrent License |
QL-5U29M-3H |
| Layered products media and
documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8 |
| DECnet/OSI end-system license |
QL-MTJAE-AA |
| DECnet/OSI extended function
license |
QL-MTKAE-AA |
|
| OpenVMS |
- OpenVMS systems include OpenVMS base license with system manager license and Compaq
Enterprise Integration Server License Package for OpenVMS Revision V3.0A.
|
- Compaq Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS,
DECwindows Motif for OpenVMS Alpha, DECprint Supervisor for OpenVMS Alpha Plus, DECprint
Supervisor for OpenVMS Open, DECnet-Plus for OpenVMS Alpha End System, Archive/Backup
System for OpenVMS Management Tools, Archive/Backup Agent for Windows NT, OpenVMS Disk
Services for Windows NT, Office Server for OpenVMS, PATHWORKS 32, PATHWORKS V6 for OpenVMS
Advanced Server, and DIGITAL Office Server Client Access License
|
- OpenVMS Concurrent Use licenses provide the right to interactively use the operating
system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS
Concurrent Use licenses can be moved from one system to another at user discretion and can
be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster.
- OpenVMS Traditional Unlimited Use license is system specific and can only be used on one
single system at a time. It cannot be shared between systems or in an OpenVMS VAX or
OpenVMS Alpha Cluster.
|
| Concurrent Use 1-user license |
QL-MT3AA-3B |
| Concurrent Use 2-user license |
QL-MT3AA-3C |
| Concurrent Use 4-user license |
QL-MT3AA-3D |
| Concurrent Use 8-user license |
QL-MT3AA-3E |
| Concurrent Use 16-user license |
QL-MT3AA-3F |
| Concurrent Use 32-user license |
QL-MT3AA-3G |
| Concurrent Use 64-user license |
QL-MT3AA-3H |
| Concurrent Use 128-user license |
QL-MT3AA-3J |
| Concurrent Use 256-user license |
QL-MT3AA-3K |
| Traditional unlimited user
license |
QL-MT2AQ-AA |
| OpenVMS V7.1-2 media and online
documentation on CD-ROM |
QA-MT1AR-H8 |
| OpenVMS V7.2-1 media and online
documentation on CD-ROM |
QA-MT1AT-H8 |
| OpenVMS media and online
documentation on CD-ROM |
QA-MT1AA-H8 |
| OpenVMS hard copy documentation |
QA-001AA-GZ |
| Layered products media and
documentation for OpenVMS on CD-ROM; includes Enterprise Integration Server for OpenVMS
media and documentation |
QA-03XAA-H8 |
| DECnet extended function license
for OpenVMS |
QL-MTGAE-AA |
| DECnet end-system to extended
function upgrade license for OpenVMS |
QL-MTHAE-AA |
| OpenVMS Cluster License for Alpha
systems |
QL-MUZAE-AA |
| OpenVMS Volume Shadowing license |
QL-2A1AE-AA |
|
| Step
20 - Hardware and Software Supplemental Support Services - Optional |
- Systems include three-year hardware warranty, on-site, with 5 x 9, 24-hour response
time; select optional Hardware Supplemental Support Services if required.
|
- Options ordered as part of "Initial System Sale" take on warranty of the
enclosure; options added after "Initial System Sale" take on warranty of
enclosure until enclosure warranty ends.
|
- All unique AlphaServer DS20 options have a minimum of one-year Return-to-Compaq
warranty.
|
| Hardware
Supplemental Support 1-GB memory or less, Americas and Asia Pacific only |
| 5 x 9, 4-hour response time |
FM-TC4HR-36 |
| 5 x 12, 4-hour response time |
FM-TC512-36 |
| 6 x 16, 4-hour response time |
FM-TC616-36 |
| 7 x 24, 4-hour response time |
FM-TC724-36 |
| Years 1-5, next day, on-site |
FM-TCXHW-60 |
| Years 1-5, 5 x 9, 4-hour response
time |
FM-TC4HR-60 |
| Years 1-5, 5 x 12, 4-hour
response time |
FM-TC512-60 |
| Years 1-5, 6 x 16, 4-hour
response time |
FM-TC616-60 |
| Years 1-5, 7 x 24, 4-hour
response time |
FM-TC724-60 |
|
| Hardware
Supplemental Support more than 1-GB memory, Americas and Asia Pacific only |
| 5 x 9, 4-hour response time |
FM-TF4HR-36 |
| 5 x 12, 4-hour response time |
FM-TF512-36 |
| 6 x 16, 4-hour response time |
FM-TF616-36 |
| 7 x 24, 4-hour response time |
FM-TF724-36 |
| Years 1-5, next day, on-site |
FM-TFXHW-60 |
| Years 1-5, 5 x 9, 4-hour response
time |
FM-TF4HR-60 |
| Years 1-5, 5 x 12, 4-hour
response time |
FM-TF512-60 |
| Years 1-5, 6 x 16, 4-hour
response time |
FM-TF616-60 |
| Years 1-5, 7 x 24, 4-hour
response time |
FM-TF724-60 |
|
| Installation
Services |
| Hardware product installation for
DS20 |
FM-TC12X-IN |
| Add-on memory installation for
DS20 |
FM-TCMEM-IN |
| Add-on CPU installation for DS20 |
FM-TCSMP-IN |
|
| Software
Supplemental Support Americas and Asia Pacific only |
| Systems include
90-day Conformance to SPD and Telephone Advisory Support; select optional Software
Supplemental Support Services, if required. |
| Software service
upgrades for Tru64 UNIX include advisory and remedial software support with new version
license rights for operating system for time period indicated. |
| Software service
upgrades for OpenVMS include advisory and remedial software support with new version
license rights for operating system and Enterprise Integration Package for time period
indicated. |
| Software service
upgrades for SMP upgrades running Tru64 UNIX or OpenVMS include new version license
rights for Tru64 UNIX or OpenVMS SMP Upgrades for time period indicated; one is required
for each SMP upgrade. |
| 5 x 9 12-month Software
Supplemental Support- Tru64 UNIX |
FM-D20U9-12 |
| 5 x 9 36-month Software
Supplemental Support- Tru64 UNIX |
FM-D20U936 |
| 5 x 9 60-month Software
Supplemental Support- Tru64 UNIX |
FM-D20U9-60 |
| 5 x 9 12-month Software
Supplemental Support- OpenVMS |
FM-D20V9-12 |
| 5 x 9 36-month Software
Supplemental Support- OpenVMS |
FM-D20V9-36 |
| 5 x 9 60-month Software
Supplemental Support- OpenVMS |
FM- D20V9-60 |
| 7 x 24 12-month Software
Supplemental Support- Tru64 UNIX |
FM-D20US-12 |
| 7 x 24 36-month Software
Supplemental Support- Tru64 UNIX |
FM-D20US36 |
| 7 x 24 60-month Software
Supplemental Support- Tru64 UNIX |
FM-D20US-60 |
| 7 x 24 12-month Software
Supplemental Support- OpenVMS |
FM-D20VS-12 |
| 7 x 24 36-month Software
Supplemental Support- OpenVMS |
FM- D20VS-36 |
| 7 x 24 60-month Software
Supplemental Support- OpenVMS |
FM- D20VS-60 |
| 12-month Software Supplemental
Support- OpenVMS or Tru64 UNIX DS20 SMP Upgrade |
FM-12SMP-12 |
| 36-month Software Supplemental
Support- OpenVMS or Tru64 UNIX DS20 SMP Upgrade |
FM-12SMP-36 |
| 60-month Software Supplemental
Support- OpenVMS or Tru64 UNIX DS20 SMP Upgrade |
FM-12SMP-60 |
|
| Hardware and
Software Supplemental Support Services Europe only |
| Europe does not offer
specific part numbers for Hardware and Software Supplemental Support Services; prices are
quoted based on worldwide service reference pricing. Contact MCS Sales in your country for
information on Hardware and Software Supplemental Support Services. |
|