Options
| Step
4 - I/O Expansion Buses - Optional |
| RETMA PCI shelf mount box for
system and I/O expansion cabinets (included) with 12 PCI slots and required cable for
connection to KFTHA-AA I/O channel; maximum of two per System Cabinet with one
StorageWorks shelf standard; see "Step 16 - Expansion: System Cabinet and I/O
Expansion Cabinet" for more details |
DWLPB-DA |
| Note:
DWLPA options are not supported on GS60E systems. |
Graphics subsystem and
diskette, includes two asynchronous serial ports, parallel port, keyboard and mouse ports,
diskette drive, extension cables for video, keyboard, and mouse.
Note: Option required to support KZPAC-AA/CA
RAID controllers - diskette drive is required to run the RAID Configuration Utility and to
support hardware partitioning. |
3X-KFE72-LA |
| Step
5 - System I/O Modules - Optional |
- Systems support a maximum of 11 I/O channels with three
KFTHA-AA modules installed and no internal storage, and 10 I/O channels with internal
storage.
|
| System I/O module (included) with
four I/O channels for DWLPB-DA shelf mount boxes, maximum three per system |
KFTHA-AA |
| Step
6 - Storage Controllers - Optional |
- Tru64 UNIX V4.0E or later supports eight KZPBA-Cx SCSI
controllers per PCI, maximum 64 per system
- OpenVMS V7.1.2 or later supports eight KZPBA-Cx SCSI
controllers per PCI, maximum 26 per system
- Tape and optical devices not supported with KZPAC SCSI RAID
controllers
- For cluster configurations, use Y cable (BN39A-0G) or SCSI
Hub (BA35X-03/05)
- Manufacturing may substitute correct cable lengths depending
on configuration
|
| |
Maximum
# Supported |
|
| |
Tru64 UNIX |
OpenVMS |
|
| |
PCI/System |
PCI/System |
|
| PCI Fibre Channel adapter
(DS-KGPSA-CA) (uses one PCI slot); requires Tru64 V4.0F (maximum 62) or V5.0A (maximum 63)
or OpenVMS V7.2-1; requires Fibre Channel cable. (DS-KGPSA-CA adapter is used with HSG60
and HSG80 Fibre Channel controllers.) FC-AL is not supported on these platforms. For best
performance, configure up to three adapters per DWLPB, one per segment. For most
connections, configure up to eight per DWLPB ? no segment restrictions. |
8/63 |
8/8 |
168794-B21 |
Fibre Channel cable (BNGBX-xx) xx
= 02, 05, 15, 30, 50 meters
x = 1, 2, 3, 4, 5 |
|
234457-B2x |
| PCI Fibre Channel tape controller
(SCSI-to-Fibre) 1 Fibre x 1 SCSI, GLM |
|
|
340654-001 |
| PCI Fibre Channel tape controller
(SCSI-to-Fibre) 1 Fibre x 2 SCSI, GBIC |
|
|
152975-001 |
| Note:
Complete cluster support available only with Veritas Net Backup |
| |
| PCI 1-port UltraSCSI Single-ended
host adapter (uses one PCI slot)- included |
8/64 |
8/26 |
KZPBA-CA |
| PCI 1-port UltraSCSI Differential
host adapter (uses one PCI slot); OpenVMS V7.1-1H1 or later supports multi-host SCSI
clusters, requires BN38C-xx cable |
8/64 |
8/26 |
KZPBA-CB |
| VHDCI male-to-68-pin HD male
UltraSCSI cable, x = 01, 02, 03, 05 meters |
|
BN38C-xx |
| |
| PCI 1-port RAID (FWSE) controller
(UltraSCSI ready) with 4-MB cache memory (uses one PCI slot) allows RAID levels 0, 0+1, 1,
and 5; includes RAID Array 230/plus subsystem software and documentation kit; 3X-KFE72-LA
option required to run RCU; tape and optical drives not supported |
4/4 |
4/4 |
KZPAC-AA |
PCI 3-port RAID (FWSE) controller
(UltraSCSI-ready) with 4-MB cache memory (uses 2 PCI slots) allows RAID levels 0, 0+1, 1,
and 5; includes RAID Array 230/plus subsystem software and documentation kit; 3X-KFE72-LA
option required to run RCU; tape and optical drives not supported; requires
BN31K-0E or KZPAC-SB for third port connection |
4/4 |
4/4 |
KZPAC-CA |
PCI 3-port RAID (FWSE) controller
(UltraSCSI-ready) with 8-MB cache memory (uses two slots) allows RAID levels 0, 0+1, 1,
and 5; includes RAID Array 230/plus subsystem software and documentation kit; 3X-KFE72-LA
option required to run RCU; tape and optical drives not supported; requires
BN31K-0E or KZPAC-SB for third port connection |
4/4 |
4/4 |
KZPAC-CB |
| SCSI cable/bulkhead assembly kit
with two ports for KZPAC-CA/CB; allows connection of one third port outputs using one PCI
bulkhead slot |
|
KZPAC-SB |
| SCSI cable/bulkhead assembly kit
with one port for KZPAC-CA/CB, allows connection of one third port output using one PCI
bulkhead slot |
|
BN31K-0E |
| 1-m VHDCI male-to-VHDCI male
UltraSCSI cable, connects KZPAC to rear-mounted StorageWorks shelf |
|
BN37A-01 |
| 2-m VHDCI male-to-VHDCI male
UltraSCSI cable, connects KZPAC to front-mounted StorageWorks shelf |
|
BN37A-02 |
| Battery backup for cache memory
option for KZPAC controller, recommended for all KZPAC controllers |
|
KZPSC-UB |
| 8-MB cache memory option |
|
MS100-BB |
| |
| PCI CI adapter, requires two
slots for adapter and power |
- |
4/26 |
CIPCA-AA |
| Same as CIPCA-AA except uses two
PCI slots for adapter |
- |
4/26 |
CIPCA-BA |
| Computer interconnect cable sets;
connects CIPCA to Star Coupler; select length10, 20, 45 m |
|
BNCIA-xx |
| Step
7 - External Storage Controllers - Optional |
- HSZ80 UltraSCSI RAID Array controllers are supported under
Tru64 UNIX V4.0E or later or OpenVMS V7.1-2 or later
- HSG80 Fibre Channel controllers require Tru64 UNIX V4.0F or
later or OpenVMS V7.2-1 or later
- HSG60 Fibre Channel controllers require Tru64 UNIX V4.0F or
later or OpenVMS V7.2-1 or later (standalone and cluster support); order one HSG60 ACS
Software Kit per HSG60
- HSJ50 CI Storage Array Controllers are supported under
OpenVMS V6.2-1H3 or later with CIPCA-AA/BA or CIXCD-AC CI controllers; QB-5C4AA-SA
software kits are required for each external cache (one for HSJ50, two for HSJ52, four for
HSJ54)
- Controllers require KZPSA, KZPBA, KFPSA, or CIPCA SCSI
adapters or controllers, as appropriate
|
| Fibre Channel controller (HSG80),
includes 256-MB cache expandable to 512 MB; requires 128697-B21 HSG80 ACS V8.4F software
kit or 128698-B21 V8.4P software kit for each HSG80 ordered |
380672-B21 |
| Fibre Channel controller (HSG60),
includes 256-MB cache expandable to 512-MB; requires 180319-B21 HSG60 ACS V8.5L software
kit (QB-6FTAA-SA) for each HSG60 ordered |
174134-B21 |
| HSG60 Tru64 UNIX Software Kit
(QB-6J4AB-SA) |
192211-B21 |
| HSG60 OpenVMS Software Kit
(QB-6J4AC-SA) |
192217-B21 |
| 256-MB Cache Option for HSG60
(DS-HSD1M-AC) |
380674-B21 |
| UltraSCSI controller (HSZ80),
includes 64-MB cache expandable to 128 MB; requires 400569-001 for Tru64 UNIX or
400571-001 for OpenVMS |
400564-B21 |
| UltraSCSI controller (HSZ80),
includes 256-MB cache expandable to 512 MB; requires 400569-001 for Tru64 UNIX or
400571-001 for OpenVMS |
400565-B21 |
| 32-MB 6-channel CI array
controller with cache battery |
HSJ50-AF |
| 64-MB cache 6-channel CI array
controller with cache battery |
HSJ50-AH |
| 128-MB cache 6-channel CI array
controller with cache battery |
HSJ50-AJ |
| Dual 64-MB cache CI array
controller with cache batteries |
HSJ52-AF |
| Dual 128-MB cache CI array
controller with cache batteries |
HSJ52-AH |
| Dual 256-MB cache CI array
controller with cache batteries |
HSJ52-AJ |
| Quad 512-MB cache CI array
controller with cache batteries |
HSJ54-AJ |
| Step
8 - Storage Devices - Optional |
- When multiple storage devices are configured with the
system, specify which devices should be installed inside the system cabinet, inside the
system expansion cabinet, or installed in the external StorageWorks cabinet. Line item
sequencing allows Manufacturing to configure storage options in the appropriate cabinet.
- List storage options to be integrated in system cabinet
immediately following system part number.
- List storage options to be integrated in StorageWorks
cabinet immediately following StorageWorks cabinet part number.
Internal Storage
- System cabinet provides space for up to four BA36R-RC/RD
StorageWorks shelves; each shelf holds a maximum of two 5.25²
devices and one 3.5² device or seven 3.5²
devices.
- System cabinet includes one UltraSCSI StorageWorks shelf
(BA36R-RC) and one PCI shelf (DWLPB-DA).
UltraSCSI Options
- Each UltraSCSI StorageWorks shelf requires SCSI controller
and SCSI cable to connect controller to shelf; refer to UltraSCSI Configuration Guidelines
(EK-ULTRA-CG.C01).
|
| UltraSCSI single-channel
StorageWorks shelf (included) with 16-bit I/O personality module (DS-BA35X-FA), 180W AC
power supply, DC fans, RETMA rackmounting hardware; supports 16-bit UltraSCSI devices and
some 8-bit narrow SCSI devices depending on compliance with minimum revision levels |
BA36R-RC |
| UltraSCSI dual-channel
StorageWorks shelf, includes 16-bit I/O personality module (DS-BA35X-FB), 180 W AC power
supply, DC fans, RETMA rack-mounting hardware; supports 16-bit UltraSCSI devices and some
8-bit narrow SCSI devices, depending on compliance with minimum revision levels. |
BA36R-RD |
Power Option for
BA36R Shelves
- An additional power supply provides N+1 power for
StorageWorks shelves; power supply uses 3.5² slot in
StorageWorks shelf, reducing total number of devices supported by one.
|
| 180W 100/120 VAC Redundant Power
Supply for StorageWorks shelf; power cords included |
CK-BA35X-HH |
| SCSI Signal
Converter |
| UltraSCSI StorageWorks DOC Signal
Converter, required to convert FWD signals from KZPBA-CB to single-ended for connection to
DS-BA35X-FA personality module in Storage-Works shelf, field installed only |
DS-BA35X-DA |
| Fast20 Personality Module for
BA356 single-ended-to-single-ended 1-channel, field installed only |
DS-BA35X-FA |
| Fast20 Personality Module for
BA356 single-ended-to-single-ended 2-channel, field installed only |
DS-BA35X-FB |
| Cable for above |
BN38C-02 |
UltraSCSI Hubs
- UltraSCSI hubs are supported with KZPBA-CB PCI differential
SCSI adapters.
|
| UltraSCSI Hub with three
differential ports (two host ports and one storage port), no single-ended ports, in 3.5² SBB, UltraSCSI cables not included |
DS-DWZZH-03 |
| UltraSCSI Hub with five
differential ports, no single ended ports, consists of four host ports and one storage
port in 5.25² SBB, UltraSCSI cables not included |
DS-DWZZH-05 |
| UltraSCSI Hub with one
differential port and two single-ended ports in 3.5² SBB,
UltraSCSI cables not included |
DS-DWZZH-21 |
16-bit Wide Drives
- For 10,000 rpm disk drives, maximum six 18-GB or larger
capacity disk drives when used in any BA356 blue shelf; 5.25" devices not supported
on same bus
|
| 36.4-GB 10,000 rpm 16-bit
UltraSCSI disk drive SBB (not supported on KZPAC controllers) |
DS-RZ1FC-VW |
| 18.2-GB 10,000 rpm 16-bit
UltraSCSI disk drive SBB (not supported on KZPAC controllers) |
DS-RZ1ED-VW |
| 18.2-GB 7,200 rpm 16-bit
UltraSCSI disk drive SBB (not supported on KZPAC controllers) |
DS-RZ1EA-VW |
| 9.1-GB 10,000 rpm 16-bit
UltraSCSI disk drive SBB |
DS-RZ1DD-VW |
| 9.1-GB 7,200 rpm 16-bit UltraSCSI
disk drive SBB |
DS-RZ1DA-VW |
Tape Devices
- Tape drives not supported with KZPAC RAID controller
|
| 8-GB DAT 3.5²
SCSI tape drive in StorageWorks carrier; requires OpenVMS V6.2-1H3 or later or Tru64 UNIX
V3.2C or later and System Console Firmware Revision 3.0-9 |
TLZ09-VA |
| 32/64-GB DAT tape loader in
StorageWorks carrier |
TLZ9L-VA |
| 12/24-GB 4mm DAT SCSI tape drive
in StorageWorks carrier |
DS-TLZ10-VA |
| 20/40-GB DLT SCSI tape drive in
5.25² StorageWorks carrier |
TZ88N-VA |
| 35/70-GB DLT SCSI tape drive in
5.25² StorageWorks carrier |
DS-TZ89N-VW |
| 40/80-GB DLT SCSI tape drive in
5.25² StorageWorks carrier; requires Tru64 UNIX V4.0F,
TruCluster V1.5 or OpenVMS V7.1 or later |
DS-TZ90N-VW |
Solid State Disks
- Supported with KZPBA controller
- Solid state disks cannot be combined with RZxx disks/tapes
on same SCSI bus
- 3.5² and 5.25²
solid state disks not supported on same SCSI bus
|
| 1.6-GB Fast20 5.25² Ultra solid state disk |
DS-EZ716-VW |
RAID Storage
Systems
- ESA 12000 Storage Arrays and RAID Array 8000 (HSG80/HSZ80)
product sets are supported on Tru64 UNIX and OpenVMS systems.
- ESA 10000 Storage Arrays and RAID Array 7000 (HSZ70 Product
Set) are supported on Tru64 UNIX and OpenVMS systems.
- Ordering and configuring information is available at www.compaq.com/products/storageworks/.
|
| External Storage
Devices |
| The following devices
can be added as required: |
| SW5XX, SW6XX,
SW8XX Storage Cabinets |
| SCSI Disk Drives |
| Tape Drives |
| TZ87, TZ857 (loader
support for Tru64 UNIX available via DECnsr), TZ877, TZ88, TZ885, TZ887, TSZ07, TLZ09,
TKZ9E , TKZ9F, TLZ9L, TKZ6x, TL810, TL812, TL820, TL822, TL826, DS-TL893-BA, DS-TL894-BA,
DS-TL896-BA, DS-TLZ10-VA, DS-TL895-xx |
| Step 9 - Networks and Communications - Optional |
- Connection of system to Ethernet requires twisted-pair
cable, except when using DE500-FA
- Requires DWLPB-DA PCI shelf mount box (one included)
- Maximum of six 3X-DEFPA-AC/DC/UC/MC FDDI controllers (100
Mb/sec) per system
- Each adapter/controller uses one PCI slot
|
| |
Maximum
# Supported |
|
| |
Tru64 UNIX |
OpenVMS |
|
| |
PCI/System |
PCI/System |
|
| Universal PCI to FDDI controller
FibreSingle attachment station (SAS) MultiMode Fibre (MMF) with SC; requires BN34x
SC type connecting cable |
6 |
6 |
3X-DEFPA-AC |
| Universal PCI to FDDI controller
FibreDual attachment station DAS) MultiMode Fibre (MMF) with SC; requires BN34x SC
type connecting cable |
6 |
6 |
3X-DEFPA-DC |
| MultiMode Fibre Optic Duplex
cable, SC connector-to-ST connector |
|
BN34A-xx |
| MultiMode Fibre Optic Duplex
cable, SC connector-to-SC connector |
|
BN34B-xx |
| MultiMode Fibre Optic Duplex
cable, SC connector-to-MIC connector |
|
BN34D-xx |
| |
Universal PCI to FDDI controller,
copper, Dual Attachment Station (DAS)
CAT 5 UTP with RJ; requires BN26x or BN25H connecting cables |
6 |
6 |
3X-DEFPA-MC |
| Universal PCI to FDDI controller,
copper, Single Attachment Station (SAS) CAT 5 UTP with RJ; requires BN26x or BN25H
connecting cables |
6 |
6 |
3X-DEFPA-UC |
| 8-pin MP-to-8-pin MP, screened,
EIA/TIA category 5 cable |
|
BN26M-xx |
| 8-pin MP-to-8-pin MP, screened,
crossover, EIA/TIA category 5 cable |
|
BN26S-xx |
| 3-m unshielded twisted pair RJ-45
connectors |
|
BN25H-03 |
| |
| PCI 1-port 10/100-Mb Ethernet
adapter (Twisted Pair); SN-PBXNP-AC (Token Ring Adapter) not supported in same system;
requires NHD1 of Tru64 UNIX. (UCX v4.2 TCP/IP Services Software not recommended for use
with DE60* devices TCP/IP V5.0 is recommended.) |
8/8 |
8/8 |
3X-DE600-AA |
| Category 5 cross-over cable for
point-to-point, unshielded |
|
BN24Q-xx |
| Category 5 cross-over cable for
point-to-point, shielded |
|
BN28Q-03 |
| Category 5 straight through for
system to repeater or hub, unshielded |
|
BN25G-xx |
| Twisted pair, shielded (-03, -04,
-07 available lengths) |
|
BN26M-xx |
| |
| PCI Gigabit Ethernet adapter, one
per DWLPB, does not support network boot |
1/4 |
1/4 |
DEGPA-SA |
| |
PCI-to-ATMworks 155 Mb Fibre
adapter, Tru64 UNIX and appropriate patch kits (patch kit 1 for V4.0F; patch kit 2 for
V4.0E) required; refer to http://www.service.
digital.com for patch kit availability, SN-PBXNP-AC PCI Token Ring Adapter is not
supported in same system with ATM 155 (DAPBA) adapter; if ATMworks 351 (DGLPA) NIC card is
installed, follow that adapters configuration rules; only one ATM adapter can be
installed on same bus as ATMworks 351 network interface card |
6 |
- |
3X-DAPBA-FA |
| Same as above except UTP |
6 |
- |
3X-DAPBA-UA |
PCI-to-ATMworks 622 Mb Fibre
adapter Tru64 UNIX and appropriate patch kits (patch kit 1 for V4.0F; patch kit 2
for V4.0E) required; refer to http://www.service.
digital.com for patch kit availability- SN-PBXNP-AC PCI Token Ring Adapter is not
supported in same system with ATM 622 (DAPCA) adapter; if ATMworks 351 (DGLPA) NIC card is
installed, follow that adapters configuration rules; only one ATM adapter can be
installed on same bus as ATMworks 351 network interface card |
1/2 |
- |
3X-DAPCA-FA |
| |
| PCI Asynchronous 4-port adapter,
maximum two PBXDA-xx per system |
2/2 |
2/2 |
PBXDA-AA |
| PCI Asynchronous 8-port adapter,
maximum two PBXDA-xx per system |
2/2 |
2/2 |
PBXDA-AB |
| PCI Asynchronous 16-port adapter,
maximum two PBXDA-xx per system |
2/2 |
2/2 |
PBXDA-AC |
| PCI Synchronous 2-port
controller, maximum two PBXDP-xx per system; requires OpenVMS V7.1-2 or Tru64 UNIX V4.0F
or V5.0A or later |
2/2 |
2/2 |
PBXDP-AA |
| PCI Synchronous 4-port
controller, maximum two PBXDP-xx per system; requires OpenVMS V7.1-2 or Tru64 UNIX V4.0x
or V5.0A or later |
2/2 |
2/2 |
PBXDP-AB |
| Note:
PBXDP-AA/AB options require WAN 3.1A kit for Tru64 UNIX V5.0A or later QA-045AA-H8
or QT-045AA-C8 |
| Step 10 - MEMORY CHANNEL - Optional |
- Up to two PCI System Area Network controllers are supported
on GS60E with Console Firmware V5.5-x or later, one per PCI bus.
- The following options are not currently supported with
MEMORY CHANNEL: DJ-ML200, CIPCA
Tru64 UNIX Systems (V5.0A and later)
- Each system node in the cluster requires a TruCluster Server
license (QL-6BRAG-AA)
Tru64 UNIX Systems (V4.0F or V4.0G)
- Requires a minimum of Tru64 UNIX V4.0F with TruCluster V1.6
or later
- Each system node in a MEMORY CHANNEL cluster requires a
TruCluster Production Server (QB-3RLAG-AA) or TruCluster MEMORY CHANNEL (QB-4ZCAG-AA)
software license.
- TruCluster MEMORY CHANNEL license (QB-4ZCAG-AA), normally
used for high- performance technical computing applications, is not required if systems
include a TruCluster Production Server license (QB-3RLAG-AA).
OpenVMS Systems
- Requires OpenVMS V7.1-2 or later and OpenVMS Cluster license
(QL-MUZAG-AA)
MEMORY CHANNEL Controller/Network Hub
- Two-node clusters can be configured by ordering a CCMAB-AA
for each system and one BN39B-04 or BN39B-10 cable; cable connects directly to CCMAB-AA in
each system
- For three or four system clusters, order one CCMAB-AA
adapter and one BN39B-04 or BN39B-10 cable for each system and one CCMHB-AA hub for the
cluster
- CCMHB-AA includes four CCMLB-AA line cards and supports up
to four nodes; expansion up to eight system nodes can be achieved by adding up to four
additional CCMLB-AA line cards
- If two or more CCMAB-AA controllers are configured in each
system, a second CCMHB-AA hub is required for clusters with more than two nodes; in 2-node
clusters the CCMAB-AA may be directly connected
- In cases where nodes must be separated by a longer distance
than standard copper cables allow, the CCMFB option converts the output of the standard
CCMAB controller or CCMLB line card to single-mode fiber optic cable. The fiber optic
connection may be up to 2,000 meters long between two CCMAB controllers connected in
virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The
connection from the CCMHB hub to a second system may also be 3,000 meters). The CCMFB
option requires a second PCI slot in the system from which it draws power only. It is
normally connected to the corresponding CCMAB controller with the short BN39B-01 cable.
The CCMFB is also used in the CCMHB hub where it occupies a slot normally used by the
CCMLB line card, limiting expansion to four radial fiber optic connections.
- The CCMHB-BA hub expansion box provides additional slots for
up to eight fiber optic connections. Two standard length, single-mode fiber optic cables
are available (BN34R-10 and BN34R-31); however, users normally provide this connection.
Customers should reference the TIA/EIA 568-A Commercial Building Telecommunications
Cabling Standard, Section 12.3.4. Fiber optic connectivity is completely transparent to
the systems using it and has no performance impact.
|
| PCI System Area Network
controller, maximum two per system, one per bus |
CCMAB-AA |
| System Area Network hub with four
line cards; includes BN19P-2E power cord for Canada, Japan, and U.S. operations;
country-specific power cord for other regions is required. |
CCMHB-AA |
| MEMORY CHANNEL hub expansion box
with no line cards |
CCMHB-BA |
| Expansion line card for CCMHB hub |
CCMLB-AA |
| 1-m cable for CCMAB, CCMHB, and
CCMFB |
BN39B-01 |
| 4-m cable for CCMAB and CCMHB |
BN39B-04 |
| 10-m cable for CCMAB and CCMHB |
BN39B-10 |
| Copper-to-single mode fiber optic
converter CCMFB must reside on the same power/PCI bus as the nodes PCI MEMORY
CHANNEL adapter module (CCMAB) that it services. It may also reside in the same hub
enclosure (up to four nodes) or a second hub enclosure (from 5-8 node utilization). |
CCMFB-AA |
| 10-m fiber optic cable |
BN34R-10 |
| 31-m fiber optic cable |
BN34R-31 |
| MEMORY CHANNEL
Power Cords |
| Australia, New Zealand |
BN19H-2E |
| Central Europe |
BN19C-2E |
| Denmark |
BN19K-2E |
| Egypt, India |
BN19S-2E |
| Ireland, United Kingdom |
BN19A-2E |
| Israel |
BN18L-2E |
| Italy |
BN35M-02 |
| Switzerland |
BN19E-2E |
| Step 11 - Console Terminal - Required unless terminal is available onsite |
- VT console terminal with EIA-232 25-pin DSUB connector is
required, (even with KFE72 installed) for system power-up, diagnostics and console
display, order unless otherwise available
- Shielded console cable included for connection to console
terminal
|
| VT510 terminal |
VT510-xx |
| Step 12 - Graphics Support for Tru64 UNIX - Optional |
- Graphics support for GS60E running Tru64 UNIX V4.0E or later
can be provided through combined use of
3X-KFE72-LA port option and SN-PBXGB-TL graphics adapter.
- SN-PBXGB-TL requires 17² or 21² Professional Series monitor and keyboard for graphics support,
unless available on-site
- Selection of video extension cable and country-specific
power cord required for all monitors
|
| Graphics subsystem for Tru64 UNIX
systems, includes diskette drive and mouse |
3X-KFE72-LA |
| GSxxx/8x00 graphics adapter |
SN-PBXGB-TL |
| Step
13 - Monitors - Optional |
17²
(16² viewable image size) professional series auto-scanning
color monitor, Trinitron CRT, 0.25 mm aperture grill pitch, VGA to 1280 x 1024 at 75 Hz,
TCO 95, MPR-II, Energy Star, attached
1.8-m video cable; requires video extension cable and country-specific power cord;
Northern Hemisphere without power cord |
3R-VRQP7-24 |
| Same as above except Southern
Hemisphere without power cord |
3R-VRQP7-23 |
| 21²
(19.6² viewable image size) auto-scanning color monitor,
Trinitron CRT, 0.25 mm aperture grill pitch, VGA to 1600 x 1200 at 75 Hz NI, TCO 95,
Energy Star, includes 1.8-m video cable; requires video extension cable and
country-specific power cord; Northern Hemisphere without power cord |
3R-VRQP1-24 |
| Same as above except Southern
Hemisphere without power cord |
3R-VRQP1-23 |
| Video Extension Cable |
|
| 1.8-m video extension cable |
BN39C-02 |
| Monitor Power Cords |
|
| Australia/New Zealand |
BN19H-2E |
| Central Europe |
BN19C-2E |
| Denmark |
BN19K-2E |
| India/South Africa |
BN19S-2E |
| Israel |
BN18L-2E |
| Italy |
BN35M-02 |
| Japan |
3X-BN46F-02 |
| North America, Japan |
BN26J-1K |
| Switzerland |
BN19E-2E |
| UK/Ireland/Hong Kong |
BN19A-2E |
| Step
14 - Keyboards - Selection of country-specific keyboard is mandatory |
| |
Tru64 UNIX |
OpenVMS |
| U.S./English keyboard |
SN-LKQ47-AA |
LK461-A2 |
| Arabic keyboard |
SN-LKQ47-BR |
- |
| Belgian keyboard |
SN-LKQ47-AB |
LK461-AB |
| BHCSY keyboard |
SN-LKQ47-AX |
- |
| Canadian/English keyboard |
- |
LK461-AQ |
| Canadian/French keyboard |
SN-LKQ47-AC |
LK461-AC |
| Cyrillic keyboard |
SN-LKQ47-BT |
LK461-BT |
| Czech keyboard |
SN-LKQ47-BV |
LK461-BV |
| Danish keyboard |
SN-LKQ47-AD |
LK461-AD |
| Dutch keyboard |
SN-LKQ47-AH |
LK461-AH |
| Finnish keyboard |
SN-LKQ47-AF |
LK461-AF |
| French keyboard |
SN-LKQ47-AP |
LK461-AP |
| German keyboard |
SN-LKQ47-AG |
LK461-AG |
| Greek keyboard |
SN-LKQ47-BH |
LK461-BH |
| Hebrew keyboard |
SN-LKQ47-AT |
LK461-AT |
| Hungarian keyboard |
SN-LKQ47-BQ |
LK461-BQ |
| International keyboard |
SN-LKQ47-BA |
- |
| Italian keyboard |
SN-LKQ47-AI |
LK461-AI |
| Korean keyboard |
SN-LKQ47-BK |
- |
| Latin-American keyboard |
SN-LKQ47-AR |
- |
| Norwegian keyboard |
SN-LKQ47-AN |
LK461-AN |
| Polish keyboard |
SN-LKQ47-BP |
LK461-BP |
| Portuguese keyboard |
SN-LKQ47-AV |
LK461-AV |
| Romanian keyboard |
- |
LK461-BL |
| S. Chinese keyboard |
SN-LKQ47-CV |
- |
| Slovak keyboard |
SN-LKQ47-CZ |
LK461-CZ |
| Spanish keyboard |
SN-LKQ47-AS |
LK461-AS |
| Swedish keyboard |
SN-LKQ47-AM |
LK461-AM |
| Swiss/French keyboard |
SN-LKQ47-AK |
LK461-AK |
| Swiss/German keyboard |
- |
LK461-AL |
| Taiwanese keyboard |
SN-LKQ47-BI |
- |
| Thai keyboard |
SN-LKQ47-CB |
- |
| Turkish keyboard |
SN-LKQ47-BU |
LK461-BU |
| Turkish/French keyboard |
- |
LK461-BW |
| UK keyboard |
SN-LKQ47-AE |
- |
| Yugoslavian keyboard |
- |
LK461-BY |
| Step 15 -
Tru64 UNIX and OpenVMS Partitions - Optional |
- A single GS60E can be divided into a maximum of two
partitions. Each partition is allocated its own set of hardware resources- CPU, memory,
and I/O module. Partitioning support requiresTru64 UNIX V4.0F or later, or OpenVMS V7.2 or
later operating system and partitioning licenses.
- System Console Firmware Revision 5.5x required
- Each partition requires a minimum of one CPU module, one
memory module, one I/O module, and one DWLPB (PCI shelf) per partition
- Each partition has its own instance of the operating system,
independent system console, and error log
- Each partition must have a dedicated console terminal. The
first partition will obtain this support in a standard manner via the server console
panel. The second partition requires a KFE72-DA to obtain this console support. H8571-J
adapter is required to connect KFE72-DA to the console terminal. The KFE72-DA does not
include a floppy diskette drive. Order 3X-KFE72-LA if a floppy or graphics support is
required.
- For more information regarding Tru64 UNIX V4.0F partitioning
configuration hardware guidelines and console partition commands, see Tru64 UNIX V4.0F SPD
41.61.22 and Tru64 UNIX V4.0F System Administration Guide, Appendix E.4.
- For more information regarding OpenVMS Galaxy
partitioning guidelines and support, see http://www.openvms.digital.com/availability/GALAXY.html
Minimum Hardware Required per GS60E Partition
- Dual Alpha 21264A 6/700-MHz CPU module
- MS7CC-EA/FA/GA memory module (1 GB, 2 GB, 4 GB)
- KFTHA-AA I/O module
- DWLPB-DA shelf mount box
- KFE72-DA serial port console or 3X-KFE72-LA
- 3X-RRDRX-AA CD-ROM drive or network adapter; additional SCSI
CD-ROM's can be configured in StorageWorks shelf using supported I/O adapters
- Console terminal with shielded console cable
- Tru64 UNIX Hardware Partition license per partition for
second partition support (QM-MT4AA-AA)
- OpenVMS software partition license is required for each CPU
in a partition (QL-66XAA-3B/3C/3D/3F )
Unsupported Options for GS60E Partitions
- MEMORY CHANNEL; clustering of a partitioned GS60E is not
supported
- NVRAM (Prestoserve Non-Volatile Random Access Memory)
- EISA devices
- Supported Options List (SOL) restriction rules still apply
for maximum configurations of GS60E systems.
|
| Step 16-
Expansion: System Cabinet and I/O Expansion Cabinet - Optional |
System Cabinet
- System Cabinet includes PCI I/O shelf and StorageWorks
shelf, and three 1600W 48 VDC power regulators for redundant hot-swappable power support
- Provides space for four BA36R-RC/RD UltraSCSI StorageWorks
Shelves, one DWLPB-DA (PCI shelf mount boxes), or two BA36R-RC/RD StorageWorks shelves and
two PCI shelves
I/O Expansion Cabinet
- Includes two 1600W 48 VDC power regulators providing N+1 hot
swappable power redundancy; third space available for additional power supply for added
power protection
- Maximum of two I/O Expansion Cabinets per system
- PCI I/O shelf included in I/O Expansion Cabinet
- Maximum of four PCI I/O shelves and three StorageWorks
shelves or four StorageWorks shelves and three PCI I/O shelves supported in each I/O
Expansion Cabinet
- StorageWorks shelves mount from top of cabinet downward,
front mount only
- PCI I/O shelves mount from bottom of cabinet upward, rear
mount only
|
| I/O Expansion Cabinet (top gun
blue) 3-phase power RETMA mounting, maximum of two per system; 120/208V US/Canada, 202V
Japan 50-60 Hz |
3X-H9A22-BA |
| Same as above except 380-415V
Europe 50-60 Hz |
3X-H9A22-BB |
Cabinet Power Options
- System Cabinet with three power supplies and I/O Expansion
Cabinet with two power supplies include necessary power and power redundancy required for
all internal system components.
|
| 1600W power converter, 48V
output, maximum of three per cabinet; option can be used to replace an existing power
regulator in the System Cabinet and I/O Expansion Cabinet or provide additional power
redundancy in the I/O Expansion Cabinet |
H7506-AA |
| Step
17 - Software - Required selection of media and documentation for first system on site |
- Software Processor Code = G
Tru64 UNIX
- Tru64 UNIX systems include Unlimited User license, Server
Extension license, Open Source Internet Solutions, and iPlanet Web Server
Enterprise Edition 4.0
When using Tru64 UNIX V5.0A or later |
| Tru64 UNIX V4 media and online
documentation on CD-ROM |
QA-6ADAA-H8 |
| Tru64 UNIX full hard copy
documentation |
QA-6ADAA-GZ |
| StorageWorks Software Package
with licenses for Logical Storage Manager and AdvFS Utilities |
QB-5RXAG-AA |
| TruCluster Server License |
QL-6BRAG-AA |
| Advanced Server for Tru64 UNIX,
25 client concurrent use license |
QL-5U29M-3D |
| Advanced Server for Tru64 UNIX,
50 client concurrent use license |
QL -5U29M-3E |
| Advanced Server for Tru64 UNIX,
100 client concurrent use license |
QL -5U29M-3F |
| Advanced Server for Tru64 UNIX,
250 client concurrent use license |
QL -5U29M-3G |
| Advanced Server for Tru64 UNIX,
500 client concurrent use license |
QL -5U29M-3H |
| Layered products media and
documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8 |
| DECnet/OSI end-system license for
Tru64 UNIX |
QL-MTJAG-AA |
| DECnet/OSI extended function
license for Tru64 UNIX |
QL-MTKAG-AA |
| When using Tru64 UNIX V4.0G or
earlier |
| Tru64 UNIX V4 media and online
documentation on CD-ROM |
QA-MT4AA-H8 |
| Tru64 UNIX V4 full hard copy
documentation |
QA-MT4AA-GZ |
| StorageWorks Software Package
with licenses for Logical Storage Manager and AdvFS Utilities |
QB-5RXAG-AA |
| TruCluster Available Server
license V4 and documentation |
QB-05SAG-AA |
| TruCluster Available Server V4
license |
QL-05SAG-AA |
| TruCluster Production Server
License |
QB-3RLAG-AA |
| Tru64 UNIX Driver for MEMORY
CHANNEL license |
QB-4ZCAG-AA |
| Advanced Server for Tru64 UNIX,
25 Client Concurrent License |
QL-5U29M-3D |
| Advanced Server for Tru64 UNIX,
50 Client Concurrent License |
QL-5U29M-3E |
| Advanced Server for Tru64 UNIX,
100 Client Concurrent License |
QL-5U29M-3F |
| Advanced Server for Tru64 UNIX,
250 Client Concurrent License |
QL-5U29M-3G |
| Advanced Server for Tru64 UNIX,
500 Client Concurrent License |
QL-5U29M-3H |
| Layered products media and
documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8 |
| DECnet/OSI end-system license |
QL-MTJAG-AA |
| DECnet/OSI extended function
license |
QL-MTKAG-AA |
OpenVMS
- OpenVMS systems include OpenVMS base license with system
manager license and Compaq Enterprise Integration Server License Package for OpenVMS
Revision V3.0A
- Compaq Enterprise Integration Package includes licenses for
TCP/IP Services for OpenVMS, DECwindows Motif for OpenVMS Alpha, DECprint Supervisor for
OpenVMS Alpha Plus, DECprint Supervisor for OpenVMS Open, DECnet-Plus for OpenVMS Alpha
End System, Archive/Backup System for OpenVMS Management Tools, Archive/Backup Agent for
Windows NT, OpenVMS Disk Services for Windows NT, Office Server for OpenVMS, PATHWORKS 32,
PATHWORKS V6 for OpenVMS Advanced Server, and DIGITAL Office Server Client Access
License
- OpenVMS Concurrent Use licenses provide the right to
interactively use the operating system by the specified number of concurrent users on a
designated OpenVMS system. OpenVMS Concurrent Use licenses can be moved from one system to
another at user discretion and can be shared in a mixed OpenVMS VAX and OpenVMS Alpha
cluster.
- OpenVMS Traditional Unlimited Use license is system specific
and can only be used on one single system at a time. It cannot be shared between systems
or in an OpenVMS VAX or OpenVMS Alpha Cluster.
|
| Concurrent Use 1-user license |
QL-MT3AA-3B |
| Concurrent Use 2-user license |
QL-MT3AA-3C |
| Concurrent Use 4-user license |
QL-MT3AA-3D |
| Concurrent Use 8-user license |
QL-MT3AA-3E |
| Concurrent Use 16-user license |
QL-MT3AA-3F |
| Concurrent Use 32-user license |
QL-MT3AA-3G |
| Concurrent Use 64-user license |
QL-MT3AA-3H |
| Concurrent Use 128-user license |
QL-MT3AA-3J |
| Concurrent Use 256-user license |
QL-MT3AA-3K |
| Traditional unlimited user
license |
QL-MT2AG-AA |
| OpenVMS V7.1-2 media and online
documentation on CD-ROM |
QA-MT1AR-H8 |
| OpenVMS V7.2-1 media and online
documentation on CD-ROM |
QA-MT1AT-H8 |
| OpenVMS media and documentation
on CD-ROM |
QA-MT1AA-H8 |
| OpenVMS base hard copy
documentation |
QA-09SAA-GZ |