| October 3,
2001 - From Version 27 to 28 |
|
Added |
|
Options |
|
| Step 5 -
M-series Cabinets - Optional |
| M-series Rackmount
Kit for AlphaServer DS10 |
- Rackmount kit must be ordered separately
|
|
| AlphaServer DS10
M-series rackmount kit |
3X-PBX01-AB |
| Note:
Factory integration of a DS10 system drawer in a Compaq 9000 rackmount cabinet using rack
kit, 3X-PBX01-AA, is not supported. Contact CustomSystems. |
|
| Step 6 -
External Storage - Optional |
| System
Disk Drives (Supported in Model 4254, 4314R, 4354R Universal Drive Shelves) |
18.2-GB
Ultra 3 SCSI, 10,000 RPM 1.0" Universal Drive |
3R-A0585-AA |
| 72.8-GB
Ultra 3 SCSI, 10,000 RPM 1.0" Universal Drive |
3R-A3050-AA |
|
| August 2,
2001 - From Version 26 to 27 |
|
Added |
|
Options |
|
External
Storage-Optional |
|
| PCI 3-channel
Ultra2 LVD RAID controller, 64-bit, 64-MB cache |
2
V4.0F/4.0G/5.1 |
- |
- |
DS-KZPCC-CE |
|
|
| PCI 1-channel
Ultra2 LVD backplane RAID controller, 64-bit, 16-MB cache |
2
V4.0F/4.0G/5.1 |
- |
- |
DS-KZPCC-AC |
|
|
Graphics
Adaptor-Optional |
|
| 3Dlabs
Oxygen VX1 32-MB PCI 2D graphics accelerator |
3 |
3 |
- |
SN-PBXGF-AB |
| Ensoniq
PCI 1373 audio card with headphone jack
and CD audio cable |
1 |
1 |
- |
SN-AVH10-AC |
|
|
Step 12 -
MEMORY CHANNEL - Optional |
|
| Tru64 UNIX
Systems |
- Requires Tru64 UNIX V5.0A or later and
either TruCluster Server License
(QL-6BRAC-AA or TruCluster Plus Software Package (QP-6R9AC-AA)
|
|
|
|
Step 14 - Software - Required selection of media
and online documentation kit for first system on site |
|
| When using Tru64 UNIX
V5.0A or later |
AdvFS Utilities
License |
QL-0EGAE-AA |
|
TruCluster Plus
Software Package with licenses for TruCluster Server, Logical Storage Manager and AdvFS
Utilities |
QP-6R9AC-AA |
|
Logical Storage
Manager License |
QL-2GVAE-AA |
|
|
|
Changed |
|
Standard
Features |
|
| OS Support, Tru64
UNIX |
AlphaServer DS10
Tru64 UNIX systems include pre-installed software (V5.1), Base license, Unlimited User
license, Server Extension license, Internet Express, iPlanet Directory Server, iPlanet
Enterprise Server, and Compaq Secure Web Server. |
|
|
Options |
|
Rackmount (M-series Cabinet)
Power Cords |
Japan,
4.5 m (right-angle connector) |
3X-BN46D-4E |
|
|
|
Removed |
|
IDE Disk
Drives |
|
40-GB 7,200 rpm IDE
drive 3X-RE58A-BA (Tru64 UNIX and Linux
ready only) |
|
Step 4 a- External Storage (Removable Media) -
Optional |
|
35/70 GB DLT tape drive in
Storage Works carrier (Tru64 UNIX and OpenVMS only) |
DS-TZ89N-VW |
|
M-series Cabinets |
|
removed all
reference to item code H9A11-MC/MD throughout document |
|
StorageWorks Shelves
Supported in M-series Cabinets with Trim Kit (H9A11) |
|
removed item
codes BA35C-AA, BA35C-AB |
|
M-series Cabinet Front
Door |
|
removed item code
H9C11-EB |
|
M-series Cabinet Factory Integration- Required |
|
removed item code
VS-ASCAA-AB |
|
Step 6 - External Storage
- Optional |
|
Table Top Drives |
removed Item code
DS-TZ89N-TA |
|
System Disk Drives (Supported in
Model 4254, 4314R, 4354R Universal Drive Shelves) |
|
removed item codes
3R-AO525-AA, 3R-AO527-AA |
|
Step 14 - Software - Required selection of media
and online documentation kit for first system on site |
|
| When using Tru64 UNIX
V5.0A or later |
StorageWorks
Software Package with licenses for Logical Storage Manager and advFS Utilities |
QB-5RXAE-AA |
|
|
When
using Tru64 UNIX V4.0G or earlier |
|
All item codes
removed pertaining to this sub-heading |
| July 10, 2001
- From Version 25 to 26 |
|
Changed |
|
Significant changes made
throughout document. |
| June 25, 2001
- From Version 24 to 25 |
|
Changed |
|
Made correction to title of
document. |
| June 21, 2001
- From Version 23 to 24 |
|
Changed |
|
Changed title to include
(466) MHz due to upcomming announcement of Compaq AlphaServer DS10 (600 MHz) Compaq
AlphaStation DS10 (600 MHz). |
| June 11, 2001
- From Version 22 to 23 |
|
Changed |
|
| AlphaServer DS10
Systems |
OS |
CPU |
Memory |
PCI
Slots |
IDE
Controller |
Ethernet
Ports |
Hard
Drive |
Order
No. |
Tru64
UNIX |
466
MHz |
256
MB |
1 |
Onboard |
Onboard |
Mandatory |
DA-PB10A-AC
|
Tru64
UNIX |
466
MHz |
512
MB |
1 |
Onboard |
Onboard |
Mandatory |
DA-PB10A-AD
|
Tru64
UNIX |
466
MHz |
1 GB |
1 |
Onboard |
Onboard |
Mandatory |
DA-PB10A-AE
|
Tru64
UNIX |
600
MHz |
256
MB |
1 |
Onboard |
Onboard |
Mandatory |
DA-73BAA-DA
|
Tru64
UNIX |
600
MHz |
512
MB |
1 |
Onboard |
Onboard |
Mandatory |
DA-73BAA-EA
|
Tru64
UNIX |
600
MHz |
1 GB |
1 |
Onboard |
Onboard |
Mandatory |
DA-73BAA-FA
|
|
|
|
|
|
|
|
|
OpenVMS |
466
MHz |
256
MB |
1 |
Onboard |
Onboard |
Mandatory |
DY-PB10A-AC
|
OpenVMS |
466
MHz |
512
MB |
1 |
Onboard |
Onboard |
Mandatory |
DY-PB10A-AD
|
OpenVMS |
466
MHz |
1 GB |
1 |
Onboard |
Onboard |
Mandatory |
DY-PB10A-AE
|
OpenVMS |
600
MHz |
256
MB |
1 |
Onboard |
Onboard |
Mandatory |
DY-73BAA-DA
|
OpenVMS |
600
MHz |
512
MB |
1 |
Onboard |
Onboard |
Mandatory |
DY-73BAA-EA
|
OpenVMS |
600
MHz |
1 GB |
1 |
Onboard |
Onboard |
Mandatory |
DY-73BAA-FA
|
|
|
|
|
|
|
|
|
Linux-Ready |
466
MHz |
512
MB |
1 |
Onboard |
Onboard |
Mandatory |
DJ-PB10A-BD
|
Linux-Ready |
466
MHz |
1 GB |
1 |
Onboard |
Onboard |
Mandatory |
DJ-PB10A-BE
|
Linux-Ready |
600
MHz |
512
MB |
1 |
Onboard |
Onboard |
Mandatory |
DJ-73BAA-EA
|
Linux-Ready |
600
MHz |
1 GB |
1 |
Onboard |
Onboard |
Mandatory |
DJ-73BAA-FA
|
|
|
|
|
|
|
|
|
|
| May
31, 2001 - From Version 21
to 22 |
|
Added |
|
At A
Glance
AlphaServer/AlphaStation DS10 3U Systems include:
- Three internal 3.5" x 1" hard disk drives or two internal 3.5" x
1" hard disk drives and one 5.25" x 1.6" removable media device
|
|
| Standard Features |
| Memory |
| Standard |
256 MB, 512 MB, or 1 GB (one
memory kit) - Tru64 UNIX, OpenVMS and
512 MB or 1 GB - Linux-Ready |
|
|
| Options |
| Step 2 -
Mandatory Options |
| Step 2a System Disk
Drive Mandatory |
| IDE Disk Drives |
40-GB 7,200 rpm
IDE drive (Tru64 Unix andLinux-Ready only)
Note: Requires console firmware update update available at http://ftp.digital.com/pub/Digital/Alpha/firmware/interim/ds10/v5.9-6/ |
3X-RE58A-BA |
|
| Step 2b Internal SCSI
Adapter and Cable Kit (Internal SCSI disks require SCSI adapter and SCSI cable
kit) |
| SCSI Adapters (for Internal
Drives) |
PCI 1-channel UltraSCSI
single-ended adapter
Note: If this adapter is used
with a TLZ10-LB tape drive or other single ended SCSI tape drive (such as the
3X-SZ35X-LB), Ultra2 or Ultra3 SCSI hard disks are not allowed on the same SCSI
bus. The TLZ10-LB tape drive must be the only device on the SCSI bus of a KZPBA-CA
adapter. It is recommended that if the system configuration contains a TLZ10-LB tape drive
select two SCSI adapters or choose a single 3X-KZPCA-AA adapter. |
KZPBA-CA |
|
|
| Step 4 -
Internal Storage (Removable Media) - Optional |
| 35/70-GB AIT tape
drive (LVD), carbon black |
3R-A2392-AA |
| Step 4 a-
External Storage (Removable Media) - Optional |
| Note:
Detailed information regarding media can be found at http://www.compaq.com/products/storageworks/mediafamily/ |
|
|
| Step 6 -
External Storage - |
| Tabletop Tape Drives |
| 35/70-GB
AIT LVD tabletop tape drive unit, US |
216885-001 |
| 35/70-GB
AIT LVD tabletop tape drive unit, International |
216885-B31 |
| 35/70-GB
AIT LVD tabletop tape drive unit, Japan |
216885-291 |
| 110/220-GB
SDLT Ultra2 LVD tabletop tape drive, US |
192103-001 |
| 110/220-GB
SDLT Ultra2 LVD tabletop tape drive, International |
192103-B31 |
| 110/220-GB
SDLT Ultra2 LVD tabletop tape drive, Japan |
192103-291 |
| Storage Controllers/Host Bus
Adapters for StorageWorks Pedestals and Shelves |
| PCI-to-Fibre
Channel 64-bit adapter, HBA |
- |
- |
2 |
DS-SWLA4-PD |
| StorageWorks
Universal Drive Shelves Single Bus Model 4314T Tower (Ultra3) |
| StorageWorks
Model 4314T, Ultra3, Universal Drive Shelves Single Bus, Tower, US |
DS-SL13T-AA |
| StorageWorks
Model 4314T, Ultra3, Universal Drive Shelves Single Bus, Tower, International |
DS-SL13T-AB |
| StorageWorks
Model 4314T, Ultra3, Universal Drive Shelves Single Bus, Tower, Japan |
DS-SL13T-AJ |
|
| Step 9 -
Monitors - Optional |
- Graphics monitors other than those listed below can be used if compatible with SVGA
graphics ordered with system
|
- Monitors ship with, but are not integrated with the system.
|
| V570
15" (13.8" viewable image size) multiple-scan color monitor, VGA to 800 x 600
@85 Hz, 0.28mm AG, TCO99, Northern Hemisphere with NA power cord |
3R-A3082-AA |
| S-510 15"
(13.8" viewable image size) multiple-scan color monitor with Invar Shadow Mask, VGA
to 1024 x 768 @ 75 Hz, 0.28mm AG, MPR II; Northern Hemisphere with Eurocord |
3R-A2832-AA
|
| Same as above, APD,
no power cord |
3R-VRQS5-24 |
| V500 15" (13.8" viewable image size) auto scanning color
monitor, VGA to 1024 x 768 @85 Hz, 0.28mm FST, MPRII, Southern Hemisphere with
Australia/New Zealand power cord |
3R-VRQV5-11 |
| P710 17"
(16" viewable image size) auto-scanning color monitor, Diamondtron NF, 0.25mm
aperture grille pitch, VGA to 1280 x 1024 @ 75 Hz, TCO 99; Northern Hemisphere with NA
power cord |
3R-A2936-AA |
| Same as above, APD,
no power cord |
3R-A2260-AA |
| Same
as above, PRC with power cord, CCIB |
3R-A3335-AA |
| Same as above,
Southern Hemisphere, with Australia/New Zealand power cord |
3R-A2263-AA |
| Same as above,
Northern Hemisphere, with Power Factor Correction and Eurocord, 220V only |
3R-A2261-AA |
| TFT
8020 18" (18.1" viewable image size) flat panel monitor, TFT active matrix,
in-plane switching technology 160 degrees viewing angles, 1280 x 1024 resolution,
brightness 200 nits, detachable base; requires ELSA GLoria Synergy or PowerStorm 3xx video
adapter |
3R-A0852-AA |
| P910 19"
(18" viewable image size) auto-scanning color monitor, Diamondtron NF, 0.25mm
aperture grille pitch, VGA to 1280 x 1024 @ 85 Hz, TCO 99; Northern Hemisphere with NA
power cord |
3R-A2935-AA |
| Same
as above, PRC with power cord, CCIB |
3R-A3334-AA |
| Same as above,
Southern Hemisphere, with Australia/New Zealand power cord |
3R-A2267-AA |
| Same as above,
Northern Hemisphere, with power factor correction and Eurocord, 220V only |
3R-A2265-AA |
| P1100
21" (19.6" viewable image size) auto-scanning color monitor, Trinitron CRT,
0.28mm aperture grille pitch, VGA to 1600 x 1200 @75Hz, TCO99, Southern Hemisphere,
Australia/New Zealand power cord |
3R-VRQP1-23 |
|
| P1210 22"
(20" viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24mm
aperture grille pitch, VGA to 1600 x 1200 @ 85 Hz, TCO 99 with power factor correction,
Northern Hemisphere with NA power cord |
3R-A2934-AA |
| Same as above with
Eurocord |
3R-VRQP2-AA |
| Same
as above, PRC with power cord, CCIB |
3R-A3333-AA |
| Same as above, APD,
no power cord |
3R-A2268-AA |
|
| Step 10 -
Networks and Communications - Optional |
| PCI-to-ATM
155 Mb adapter- Fiber |
2
V4.0F |
2
V7.2-1 |
- |
3X-DAPBA-FA |
| PCI-to-ATM
155 Mb adapter- UTP |
2
V4.0F |
2
V7.2-1 |
- |
3X-DAPBA-UA |
| PCI-to-ATM
622 Mb adapter - Fiber |
1
V4.0F |
2
V7.2-1 |
- |
3X-DAPCA-FA |
| Step 15 -
Hardware and Software Support Services |
- Select one of the optional CarePaq Priority Service Packages described below that best
supports the customers operational requirements for system availability.
|
| CarePaq
Priority Services |
| CarePaq Priority
Services are available for Compaq AlphaServer/AlphaStation systems running Compaq Tru64
UNIX or OpenVMS operating systems. Priority Services are designed for the growing number
of customers who need support beyond the basic warranty. Five packages are offered -
Priority, Priority 24, Priority Silver, Priority Gold, and Priority Executive with
coverage for both Principal servers/stations and SSPs (Subsequent System Packages) - that meet a full range of customer support requirements. |
|
| Program
Features Principal Server/Station |
| Priority |
|
|
- 4-hour response on-site hardware support
|
- 2-hour response for Bronze software support
|
- License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
- Condist update distribution for OpenVMS or Tru64 UNIX and their layered products.
(Layered products not included on Condist can be ordered separately.)
|
| Priority 24 |
|
|
|
|
- 4-hour response on-site hardware support
|
- 2-hour response for Bronze software support
|
- License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
- Condist update distribution for OpenVMS or Tru64 UNIX and their layered products.
(Layered products not included on Condist can be ordered separately.)
|
| Priority
Silver |
- 24x7 HW Support with Named Engineer, 4-hour response
|
- 24x7 Silver SW Support - Named Account Rep, 1-hour response Monday Friday,
8AM-5PM local time; 2-hour response remaining hours
|
- License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
- Condist update distribution for OpenVMS or Tru64 UNIX and their layered products.
(Layered products not included on Condist can be ordered separately.)
|
- Technical newsletter and SW activity review
|
- Proactive Patch Notification
|
- One (1) System Healthcheck per year
|
| Priority Gold |
- 24x7 HW support with Named Engineer, 4-hour response for on-site support
|
- 24x7 Gold SW support - Named Account Rep
|
- 30-minute callback (critical); 1-hour callback (non-critical)
|
- License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
- Condist update distribution for OpenVMS or Tru64 UNIX and their layered products.
(Layered products not included on Condist can be ordered separately.)
|
- Technical newsletter, SW activity review and 10 hours Upgrade impact planning
|
- Proactive Revision Management
|
- Two (2) System Healthchecks per year
|
- Mandatory pre-qualification required
|
| Priority Gold
Executive |
- 24x7 HW support with Named Engineer, two-hour response for on-site support
|
- 24x7 Gold SW support - Named Account Rep
|
- 30-minute callback (critical); one-hour callback (non-critical)
|
- License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS,
unlimited users, and server extensions for Tru64 UNIX)
|
- Software update distribution on CD-ROM: OpenVMS or Tru64 UNIX and their layered products
(Layered products not included on Condist can be ordered separately.)
|
- Technical newsletter, SW activity review and 10 hours Upgrade impact planning
|
- Proactive Revision Management
|
- Two (2) System Healthchecks per year
|
- Customer site must be within 25 miles of a Compaq service location
|
- Mandatory pre-qualification required
|
|
| Program
Features Additional Services |
| SSPs
(Subsequent System Packages) |
- For Priority, Priority 24, Priority Silver, Priority Gold, and Priority Gold Executive
|
- HW Support at same level as corresponding package for Principal server/station
|
- License Subscription: Compaq O/S (where applicable)
|
- Telephone support through Principal server/station covered by full support package
|
| Installation |
|
|
|
|
|
|
|
|
- No software installation added
|
| Installation
& Startup Compaq O/S |
|
|
|
|
|
|
|
|
- Install operating systems
|
|
|
|
|
|
|
|
Model/CarePaq
Priority Service |
Principal
Server/Station
1 year |
Principal
Server/Station
3 years |
Subsequent
Systems
1 year |
Subsequent
Systems
3 years |
| AlphaServer/AlphaStation
DS10 |
| Priority |
FP-A01BA-12 |
FP-A01BA-36 |
FP-A21BA-12 |
FP-A21BA-36 |
| Priority 24 |
FP-A02BA -12 |
FP-A02BA-36 |
FP-A22BA-12 |
FP-A22BA-36 |
| Priority Silver |
FP-A04BA-12 |
FP-A04BA-36 |
FP-A24BA-12 |
FP-A24BA-36 |
| Priority Gold |
FP-A08BA-12 |
FP-A08BA-36 |
FP-A28BA-12 |
FP-A28BA-36 |
| Priority Gold
Exec. |
FP-A09BA-12 |
FP-A09BA-36 |
FP-A29BA-12 |
FP-A29BA-36 |
| Installation |
FP-AINST-BA |
FP-AINST-BA |
FP-AINST-BA |
FP-AINST-BA |
| Installation
& Startup |
FP-ASTAR-BA |
FP-ASTAR-BA |
FP-ASTAR-BA |
FP-ASTAR-BA |
Notes:
- AlphaServer/AlphaStation DS10 systems include three years hardware warranty with 5x9,
on-site Next Business Day response.
- New Compaq hardware options internal to the AlphaServer/AlphaStation enclosure receive
the same warranty or service level as purchased with the server or station.
- External storage devices/cabinets carry their own level of warranty and should be quoted
separately for uplifted warranty services (CarePaq Priority Service).
- In addition to the CarePaq Priority Services, uplifted warranty Supplemental Services
are available for separate hardware and software support. For more information on Hardware
and Software Supplemental Services and other Compaq service options available for
AlphaServers and AlphaStations, consult your Compaq Sales Account Manager or visit
http://www.compaq.com/services/
|
|
|
Removed |
|
At A
Glance AlphaServer/AlphaStation DS10 3U Systems
include:
- One 5.25² x 1.6² removable media
bay or two 3.5² x 1² hard
disk drive bays, one 3.5² x 1²
hard disk drive bay
| Options |
| Step 2 -
Mandatory options |
| Step 2a -
System Disk Drive - Mandatory |
- For multiple system configurations that share a system disk external to system
enclosure, contact Compaq CustomSystems
|
|
| Step 2b Internal SCSI
Adapter and Cable Kit (Internal SCSI disks require SCSI adapter and SCSI cable
kit) |
| SCSI Adapters (for
Internal Drives) |
PCI
1-channel UltraSCSI single-ended adapter Note: If this adapter is used with a TLZ10-LB
tape drive or other single ended SCSI tape
drive (such as the 3X-SZ35X-LB), Ultra2 or Ultra3 SCSI hard disks are not allowed on the
same SCSI bus. The TLZ10-LB tape drive must be the only device on the SCSI bus of a
KZPBA-CA adapter. It is recommended that if the system configuration contains a TLZ10-LB
tape drive select two SCSI adapters or choose a single 3X-KZPCA-AA adapter. |
KZPBA-CA |
| Please
note that all instances where the above adapter is mentioned have been removed. |
| PCI 1-channel Ultra2
LVD SCSI adapter (Tru64 UNIX and
OpenVMS only) |
3X-KZPCA-AA |
| Step 9 -
Monitors - Optional |
- AlphaServer DS10L has been designed for desktop use and will support a 21" monitor
|
|
|
|
| Systems/Options |
| Step 1 - Select system |
| AlphaServer DS10 Systems |
| OS |
CPU |
Memory |
PCI Slots |
IDE Controller |
Ethernet Ports |
Hard Drive |
Order No. |
| Linux-Ready |
466 MHz |
256 MB |
4 |
Onboard |
Onboard |
Mandatory |
DJ-PB10A-BC |
| Linux-Ready |
600 MHz |
256 MB |
4 |
Onboard |
Onboard |
Mandatory |
DJ-73BAA-DA |
|
| AlphaStation DS10 Systems |
| Linux-Ready |
600 MHz |
256 MB |
4 |
Onboard |
Onboard |
Mandatory |
DJ-73BAA-DW |
|
| Options |
| Step 2 -
Mandatory Options |
| Step 2a System Disk
Drive Mandatory |
| IDE Disk Drives |
| 10-GB
7,200 rpm IDE drive |
3X-RE56A-BA |
| Step 2b Internal SCSI
Adapter and Cable Kit (Internal SCSI disks require SCSI adapter and SCSI cable
kit) |
PCI 2-channel
multi-mode Ultra3 LVD SCSI adapter, VHDCI not factory installed (Tru64 UNIX V5.1
only)
Note: Patch kit required, kit available
at http://ftp1.support.compaq.com/public/Digital_UNIX/v5.1/ |
3X-KZPEA-DB |
|
|
| Step 3 -
Memory - Optional |
| 128-MB memory
kit, two 200-pin, 100-MHz, 64-MB DIMMs |
3X-MS310-BA |
| Step 4 -
Internal Storage (Removable Media) - Optional |
| 4/8-GB
DAT 4 mm internal SCSI tape drive (requires SN-PBXKP-BA wide-to-narrow SCSI adapter)
(Tru64 UNIX and OpenVMS only) |
TLZ09-LK |
|
|
| Step 6 -
External Storage - |
| 5, 7,
10, 14-GB 8-mm tabletop, single-ended SCSI |
TKZ9F-TA |
| StorageWorks
Universal Drive Shelves - Model 4254 (Ultra2 SCSI/LVD) |
StorageWorks
Model 4254 enclosure; Ultra2 SCSI (LVD) split-bus universal drive shelf (Refer to Compaq
StorageWorks Enclosure 4200 QuickSpec when configuring shelf)
When selecting a DS-SSL14-Rx split-bus shelf, order two 3X-KZPCA-AA adapters;
Model 4254 enclosures are compatible with Wide Ultra2 (LVD) adapters only
Note: The depth of a DS-SSL14-Rx shelf does not allow front and rear mounting, US. |
DS-SSL14-RS |
| Same
as above, International |
DS-SSL14-R3 |
| Same
as above, Japan |
DS-SSL14-R4 |
| Step 9 -
Monitors - Optional |
- Graphics monitors other than those listed below can be used if compatible with SVGA
graphics ordered with system
|
- Selection of video extension cable and country-specific power cord is mandatory for all
monitors
|
| 15² Corporate Series auto-scan color monitor, VGA to 1024 x 768 @ 85
Hz; Northern Hemisphere without power cord |
3R-VRQV5-24 |
| Same
as above except Southern Hemisphere without power cord |
3R-VRQV5-11 |
| S-510 15"
(13.8" viewable image size) multiple-scan color monitor with Invar Shadow Mask, VGA
to 1024 x 768 @ 75 Hz, 0.28mm AG, MPR II; Northern Hemisphere with NA power cord |
3R-A2832-AA
|
| Same
as above, with Eurocord |
3R-A2832-AA |
17² (16² viewable image size) professional
series auto-scanning color monitor, Trinitron CRT, 0.25 mm aperture grill pitch, VGA to
1280 x 1024 at 75 Hz, TCO 95, MPR-II, Energy Star, attached
1.8-m video cable; Northern Hemisphere without power cord |
3R-VRQP7-24 |
| Same
as above except Southern Hemisphere without power cord |
3R-VRQP7-23 |
| 19² (18² viewable image size) professional
series auto-scanning color monitor, flat definition Trinitron CRT, 0.25 mm aperture grill
pitch, VGA to 1280 x 1024 at 75 Hz, TCO 99, MPR-II, Energy Star, attached 1.8-m video
cable; without power cord, Northern Hemisphere |
3R-VRQP9-24 |
| Same
as above, Southern Hemisphere |
3R-VRQP9-23 |
| 21² (19.8² viewable image size)
auto-scanning color monitor, Trinitron CRT, 0.25 mm aperture grill pitch, VGA to 1600 x
1200 at 75 Hz NI, TCO 95, Energy Star, includes 1.8-m video cable; Northern Hemisphere
without power cord |
3R-VRQP1-24 |
| Same
as above except Southern Hemisphere without power cord |
3R-VRQP1-23 |
|
|
| Step 11 -
Keyboards, Mouse |
| Step 11a -
Keyboards |
| International
keyboard |
SN-LKQ47-BA |
- |
| Step 15 -
Hardware and Software Support Services |
| Hardware
Supplemental Services |
- Systems include three-year, onsite hardware warranty with next business day response
|
- Select optional Hardware Supplemental Services if required
|
| 3-year,
5 x 9, 4-hour response time |
FM-1D4HR-36 |
| 5-year,
5 x 9, 4-hour response time |
FM-1D4HR-60
|
| 3-year,
7 x 24, 4-hour response time |
FM-1D724-36 |
| 5-year,
7 x 24, 4-hour response time |
FM-1D724-60 |
| Years
4-5, 5 x 9, next day response time |
FM-1DXHW-60 |
|
| Software
Supplemental Services |
Tru64
UNIX |
OpenVMS |
| 1-year,
5 x 9 Bronze Software Supplemental Support |
FM-D10U9-12 |
FM-D10V9-12 |
| 3-year,
5 x 9 Bronze Software Supplemental Support |
FM-D10U9-36 |
FM-D10V9-36 |
| 5-year,
5 x 9 Bronze Software Supplemental Support |
FM-D10U9-60 |
FM-D10V9-60 |
| 1-year,
7 x 24 Bronze Software Supplemental Support |
FM-D10US-12 |
FM-D10VS-12 |
| 3-year,
7 x 24 Bronze Software Supplemental Support |
FM-D10US-36 |
FM-D10VS-36 |
| 5-year,
7 x 24 Bronze Software Supplemental Support |
FM-D10US-60 |
FM-D10VS-60 |
| 1-year,
Bronze Node Software Supplemental Support |
FM-D10UN-12 |
FM-D10VN-12 |
| 3-year,
Bronze Node Software Supplemental Support |
FM-D10UN-36 |
FM-D10VN-36 |
| 5-year,
Bronze Node Software Supplemental Support |
FM-D10UN-60 |
FM-D10VN-60 |
|
| Installation
Services |
| Hardware
product installation for AlphaServer/AlphaStation DS10 |
FM-1DINS-IN |
|
|
Changed |
|
| Standard Features |
| Expansion |
| Storage bays |
Five (diskette
drive bay, CD-ROM drive bay, and three storage bays (three internal 3.5" x 1"
hard disk drives or two internal 3.5" x 1" hard disk drives and one 5.25" x
1.6" removable media device |
| PCI slots |
Four full-length slots
(three 64-bit, one 32-bit) |
| Storage |
| Diskette Drive |
1.44-MB diskette drive |
| CD-ROM |
5.25²
half height 40X CD-ROM drive |
| Hard Drives |
20-GB, 30-GB,
and 40-GB IDE disk drives or 9.1-GB, 18.2-GB,
36.4-GB Wide Ultra3 SCSI disk drives available with optional SCSI controller |
|
|
| options |
| Step 5 -
M-series Cabinets - Optional |
| Cabinet Configuration Chart
for AlphaServer DS10 (3U) with StorageWorks Shelves (4U) |
M-series
Cabinet |
System Rack Kit per DS10
system |
M-series Cabinet Height/Space |
AlphaServer DS10 Systems |
StorageWorks BA356/ DS-SL13R Disk
Shelves |
Ballast Kits Required |
|
|
| Options |
| Step 6 -
External Storage - Optional |
|
Maximum #
Supported |
|
|
Tru64 UNIX |
OpenVMS |
Linux-Ready |
|
| PCI 1-port Ultra2 SCSI (LVD)
adapter, 68-pin HD connector, requires BN38C cable (2 to 20m) to connect to single-ended
UltraSCSI or LVD shelf |
2 |
2 |
3 |
3X-KZPCA-AA |
|
|
| Step 6 -
External Storage - |
| 35/70-GB SCSI (DLT7000) tabletop tape drive (Tru64 and OpenVMS only) |
DS-TZ89N-TA |
| 40/80-GB SCSI LVD (DLT8000) tabletop tape drive -
Worldwide |
146197-B21 |
| 40/80-GB SCSI LVD (DLT8000) tabletop tape drive -
Japan |
146197-291 |
| StorageWorks Universal Drive
Shelves Model 4200 to Model 4300
Upgrade I/O Modules |
| Step 15 - Hardware and Software Support Services |
|
| April
10, 2001 - From Version 20
to 21 |
|
Added |
|
Change affected Canada QuickSpecs only. |
| March
28, 2001 - From Version 19
to 20 |
|
Added |
|
Systems/Options |
|
Step
2 - Select mandatory options |
|
| IDE Disk Drive |
| 20-GB 7,200 rpm
IDE drive |
3X-RE58A-AA |
|
|
Options |
|
Step
6 - External Storage |
|
|
|
Technical
Specifications |
|
Acoustics
(Declared values per ISO 9296 and ISO 7779)
AlphaServer DS10 with one HDD
Idle
Operating |
LWAdB
5.7
6.0 |
LpAm,
dBA (Operator position)
48
52 |
LpAm,
dBA (Bystander Position)
41
45 |
|
|
|
|
Removed |
|
Options |
|
Step
2b - SCSI Adapters (for Internal drives) |
|
| PCI combo card: PCI 2-channel
UltraSCSI single-ended adapter and 10/100 Mbit Ethernet (Tru64 UNIX
and OpenVMS only) |
KZPCM-DA |
|
|
|
|
| PCI 3-channel
Ultra2 SCSI LVD RAID controller, 64-MB cache (Tru64 UNIX V4.0F) |
DS-KZPCC-CE |
| PCI 1-channel
Ultra2 SCSI LVD RAID controller, 64-bit, 16-MB cache (Tru64 UNIX only) |
DS-KZPCC-AC |
|