AlphaServer/AlphaStation DS10 3U Systems include:

  • Alpha processor module with either a 466-MHz or 600-MHz CPU with 2-MB onboard ECC cache
  • 256-MB, 512-MB, or 1-GB SDRAM memory - expandable to 2-GB maximum memory capacity
  • Onboard dual IDE controller for internal storage
  • Onboard dual 10/100 BaseT Ethernet ports
  • Four PCI expansion slots - three 64-bit PCI slots and one 32-bit PCI slot
  • 1.44-MB diskette drive
  • 40X 600-MB CD-ROM drive
  • Three internal 3.5" x 1" hard disk drives or two internal 3.5" x 1" hard disk drives and one 5.25" x 1.6" removable media device
  • Internal storage capacity up to 109 GB (SCSI)
  • Two serial ports: COM1 port is both an RMC port with modem control and a full-duplex asynchronous communications port; COM2 port is a full-duplex asynchronous communications port
  • Bi-directional enhanced parallel port
  • PS/2-style keyboard port and mouse port
  • 300W (120/240V, 60/50 Hz) power supply
  • U.S. English documentation
  • Tru64ä UNIX or OpenVMS Factory Installed Software; Linux-Ready systems available
  • 90-day software product warranty
  • Protected by Compaq Services, including three-year, on-site hardware with next business day response

Note: Keyboard, power cord, and mouse must be ordered separately

contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Standard Features
    
Processor Alpha 21264 466-MHz processor
 
Cache Memory 2-MB onboard cache
  
Upgradability Supports upgrades of memory and hard drives
Standard One CPU
   
Memory Standard 256 MB, 512 MB, or 1 GB (one memory kit) - Tru64 UNIX, OpenVMS and
512 MB or 1 GB - Linux-Ready
Maximum

2 GB (two memory kits, kits include two industry-standard DIMMs with ECC support)

 
Network Controller Onboard dual 10/100 BaseT Ethernet ports
  
Expansion Storage bays Five (diskette drive bay, CD-ROM drive bay, and three storage bays – three internal 3.5" x 1" hard disk drives) or two internal 3.5" x 1" hard disk drives and one 5.25" x 1.6" removable media device
PCI slots Four full-length slots (three 64-bit, one 32-bit)
  
Storage Diskette Drive

1.44-MB diskette drive

CD-ROM

5.25² half height 40X CD-ROM drive

Hard Drives 20-GB, and 40-GB IDE disk drives or 9.1-GB, 18.2-GB, 36.4-GB Wide Ultra3 SCSI disk drives available with optional SCSI controller
   
Storage Controller Onboard IDE controller for internal storage, choice of optional storage controllers
  
Expansion Ports Parallel One bi-directional enhanced port
Serial Two ports, one serial port with full-duplex asynchronous modem control and one RMS dedicated serial port with full-duplex asynchronous modem control
Keyboard One PS/2-style port
Mouse One port
  
Power Supply 300W (120/240V, 60/50 Hz)
 
Manageability Compaq Insight Manager
 
Supported Options A detailed summary of options supported on the AlphaServer/AlphaStation DS10 is available at http://www.compaq.com/alphaserver/options/asds10/ds10_options.html
  
OS Support AlphaServer DS10 Tru64 UNIX systems include pre-installed software (V5.1), Base license, Unlimited User license, Server Extension license, Internet Express, iPlanet Directory Server, iPlanet Enterprise Server, and Compaq Secure Web Server.
AlphaStation DS10 Tru64 UNIX systems include pre-installed software (V5.1), 2-user Base license, and Compaq Open3D traditional license.
AlphaServer DS10 OpenVMS systems include pre-installed software (V7.2-1), Base license with System Manager license and Compaq Enterprise Integration Server License Package for OpenVMS V3.0A.
AlphaStation DS10 OpenVMS systems include pre-installed software (V7.2-1), Base license, Concurrent Use 1-user license, NAS 150 Client license, and Compaq Open3D traditional license.
Minimum OS support: Tru64 UNIX V4.0F or OpenVMS V7.1 -2
  
Service and Support Protected by Compaq Services, including a three-year, on-site hardware warranty with next business day response. Software warranty is a 90-day telephone advisory. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support.
contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Systems/Options
   
Step 1 - Select system
AlphaServer/AlphaStation DS10 systems require the mandatory selection of the following items:
  • IDE or SCSI system disk drive
  • SCSI adapter and SCSI cable kit required for internal SCSI disks and tape
  • Country-specific power cord
  • Software media and documentation for first system on site
  • Rackmount kit for rackmount systems (See Step 5 – M-series Cabinet Enclosures)
  • Minimum OS support: Tru64 UNIX V4.0F or OpenVMS V7.1-2

Notes: Country-specific keyboard and mouse are recommended
For system integration of any options with 6-3 part numbers, contact CustomSystems

  
AlphaServer DS10 Systems

OS

CPU

Memory

PCI Slots

IDE Controller

Ethernet Ports

Hard Drive

Order No.

Tru64 UNIX

466 MHz

256 MB

1

Onboard

Onboard

Mandatory

DA-PB10A-AC

Tru64 UNIX

466 MHz

512 MB

1

Onboard

Onboard

Mandatory

DA-PB10A-AD

Tru64 UNIX

466 MHz

1 GB

1

Onboard

Onboard

Mandatory

DA-PB10A-AE

  

OpenVMS

466 MHz

256 MB

1

Onboard

Onboard

Mandatory

DY-PB10A-AC

OpenVMS

466 MHz

512 MB

1

Onboard

Onboard

Mandatory

DY-PB10A-AD

OpenVMS

466 MHz

1 GB

1

Onboard

Onboard

Mandatory

DY-PB10A-AE

  

Linux-Ready

466 MHz

512 MB

1

Onboard

Onboard

Mandatory

DJ-PB10A-BD

Linux-Ready

466 MHz

1 GB

1

Onboard

Onboard

Mandatory

DJ-PB10A-BE

contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Options
    
Step 2 - Mandatory options
Step 2a - System Disk Drive - Mandatory
  • Selection of one system disk drive is mandatory
AlphaServer DS10 Storage Configuration Rules:
  • Systems include 600-MB 40X CD-ROM drive and 1.44-MB diskette drive in dedicated drive slots
  • Systems include three internal storage bays that can be configured as follows:
    -    Maximum of three internal disk drives (3.5" x 1" drives) or
         two internal disk drives (3.5" x 1") and one removable 5.25" half height removable media
         device (one 3.5² x 1² hard disk drive is supported in removable media bay)
  • SCSI adapter and SCSI cable kit required for SCSI disks or tapes
    
IDE Disk Drives 20-GB 7,200 rpm IDE drive

3X-RE58A-AA

40-GB 7,200 rpm IDE drive

3X-RE58A-BA

Note: Requires console firmware update – update available at http://ftp.digital.com/pub/Digital/Alpha/firmware/interim/ds10/v5.9-6/

Internal SCSI Disk Drives 9.1-GB 7,200 rpm Ultra2 SCSI drive

DS-RZ2DA-WA

9.1-GB 10,000 rpm Ultra3 SCSI drive

DS-RZ3DD-WA

18.2-GB 7,200 rpm Ultra2 SCSI drive

DS-RZ2EA-WA

18.2-GB 10,000 rpm Ultra3 SCSI drive

DS-RZ3EF-WA

36.4-GB 10,000 rpm Ultra3 SCSI drive

DS-RZ3FD-WA

      
Step 2b – Internal SCSI Adapter and Cable Kit –
(Internal SCSI disks require SCSI adapter and SCSI cable kit)
SCSI Adapters (for Internal Drives) PCI 1-channel Ultra2 LVD SCSI adapter

3X-KZPCA-AA

PCI 2-channel multi-mode Ultra3 LVD SCSI adapter, VHDCI (Tru64 UNIX V5.1 only)
Note: Patch kit required, kit available at http://ftp1.support.compaq.com/public/Digital_UNIX/v5.1/

3X-KZPEA-DB

PCI combo card–PCI 2-channel UltraSCSI single-ended adapter and 10/100 Mbit Ethernet

KZPCM-DA

PCI combo card–PCI 1-channel Ultra2 LVD SCSI, 2D Graphics, 10/100 Ethernet (Tru64 UNIX and OpenVMS only)

3X-DEPVZ-AA

PCI 1-channel UltraSCSI RAID controller (Tru64 UNIX and OpenVMS only)

KZPAC-AA

PCI 3-port UltraSCSI RAID controllers (4-MB/8-MB cache) (Tru64 UNIX V4.0F, OpenVMS V7.2-1)

KZPAC-CA/CB

PCI 1-channel Ultra2 SCSI RAID controller, 4-MB cache (Linux-Ready Systems only)

SN-KZPBC-AA

PCI 3-channel Ultra2 SCSI RAID controller, 32-MB cache (Linux-Ready Systems only)

FR-PCTAR-IB

PCI 3-channel Ultra2 SCSI RAID controller, 64-MB cache (Linux-Ready Systems only)

FR-PCTAR-IC

SCSI Cable Kit AlphaServer DS10 SCSI cable kit (connections for three internal drives)

3X-BN51A-SE

Step 2c - Power Cords – Mandatory for Desktop and Rackmount Systems
Desktop Power Cords North America, 2.5 m

3X-BN46K-2E

Australia, New Zealand, 2.5 m

BN19H-2E

Central Europe, 2.5 m

BN19C-2E

China, Australian AS 3112-1981

BN35S-02

China, NA NEMA 5-15 plug

BN35A-01

Denmark, 2.5 m

BN19K-2E

Egypt, India, South Africa, 2.5 m

BN19S-2E

Israel, 2.5 m

BN18L-2E

Italy, 2.5 m

BN19M-2E

Japan, 2.5 m, Dentori approved

3X-BN46G-02

Switzerland, 2.5 m

BN19E-2E

UK, Ireland, 2.5 m

BN19A-2E

     
Rackmount (M-series Cabinet) Power Cords US/Canada

BN20Z-4E

Non-US

3X-BN46L-4E

Japan, 4.5 m (right- angle connector)

3X-BN46D-4E

     
Step 3 - Memory - Optional
  • Maximum 2-GB memory
  • Systems include one memory kit; maximum two memory kits per system - Each kit includes two industry-standard DIMMs with ECC support
256-MB memory kit, two 200-pin, 100-MHz, 128-MB DIMMs

3X-MS310-CA

512-MB memory kit, two 200-pin, 100-MHz, 256-MB DIMMs

3X-MS310-DA

1-GB memory kit, two 200-pin, 100-MHz, 512-MB DIMMs (Tru64 UNIX and OpenVMS only)

3X-MS310-EA

          
Step 4 - Internal Storage (Removable Media)- Optional
AlphaServer DS10 Storage Configuration Rules:
  • Systems include 600-MB 40X CD-ROM drive and 1.44-MB diskette drive in dedicated drive slots
  • Systems include three internal storage bays which can be configured as follows:

     Three internal disk drives (3.5" x 1" drives) or
       two internal disk drives (3.5" x 1") and one 5.25" half height removable media          device (one 3.5² x 1² hard disk drive is supported in removable media bay)

  • SCSI Host Bus adapter and SCSI cable kit required for internal SCSI disks or tapes
12/24-GB DAT 4mm internal SCSI tape drive (requires SN-PBXKP-BA wide-to-narrow SCSI adapter) (Tru64 UNIX and OpenVMS only)

TLZ10-LB

20/40-GB DAT tape drive, top gun blue (Tru64 UNIX and OpenVMS only)

3X-SD20X-LB

35/70-GB AIT tape drive, top gun blue (Tru64 UNIX and OpenVMS only)

3X-SZ35X-LB

35/70-GB AIT tape drive (LVD), carbon black

3R-A2392-AA

50/100-GB AIT tape drive, top gun blue (Tru64 UNIX and OpenVMS only)

3X-SZ50X-LB

Wide-to-narrow SCSI adapter

SN-PBXKP-BA

     
Step 4-a- External Storage (Removable Media) - Optional
40/80-GB DLT tape drive in StorageWorks carrier

DS-TZ90N-VW

20/40-GB DLT tape drive in StorageWorks carrier (Tru64 UNIX and OpenVMS only)

TZ88N-VA

Note: Detailed information regarding media can be found at http://www.compaq.com/products/storageworks/mediafamily/
       
Step 5 - M-series Cabinets - Optional
M-series cabinet enclosures support up to 12 AlphaServer DS10 systems (H9A15)
M-series enclosures require selection of the following items:
  • H9A10 or H9A15 Cabinet, 120V or 240V
  • Cabinet front door based on cabinet height (optional on H9A11 cabinet)
  • Factory integration
  
Cabinet Configuration Chart for AlphaServer DS10 Rackmount Systems:
  • A minimum of two AlphaServer DS10 systems is required in the H9A15 M-series cabinet.
  • Each system requires an AlphaServer DS10 M-series Rackmount kit (3X-PBX01-AB).
  • Each system requires a rack mount power cord.
  • Up to six BA356 shelves supported; shelves cannot be mounted behind AlphaServer DS10 systems.
Notes: The number of ballast kits required is determined by the number of system boxes. Ballast kits are required according to the following chart:
For more information on M-series Cabinet Enclosures, see
www.compaq.com/alphaserver/products/m-series/index.html
   
Cabinet Configuration Chart for AlphaServer DS10 (3U) with StorageWorks Shelves (4U)

M-series
Cabinet

System Rack Kit per DS10 system

M-series Cabinet Height/Space

AlphaServer DS10 Systems

StorageWorks BA356/DS-SL13R Disk Shelves

Ballast Kits Required

H9A10-MC/MD

3X-PBX01-AB

56² / 32U

1 or 2

6

2

3 or 4

6

1

5

6

1

6

4

0

7

2

0

8, 9, or 10

0

0

H9A15-MC/MD

3X-PBX01-AB

66.5² / 39U

2 or 3

6

2

4

6

1

5

6

1

6

4

1

7

2

0

8 to 12

0

0

    
Cabinet Configuration Chart for AlphaServer DS10 (3U) Rackmount Systems with RA3000 and Disk Shelves (12U)
  • 12U of vertical cabinet space is reserved for one RA3000 controller shelf and up to five disk shelves mounted in top of cabinet, front to back; an additional 2U of vertical space is required for RA3000 controller shelf UPS.
  • Disk shelves can be a combination of RA3000 DS-SWXRA-GN disk shelves and StorageWorks BA36R-RC/RD disk shelves.
  • RA3000 controller shelf supports a maximum of four DS-SWXRA-GN disk shelves; third and fourth
    DS-SWXRA-GN disk shelf ordered will be installed in rear of M-series cabinet; rear mounted shelves require that a 2-m SCSI cable (BN37A-02) be ordered separately.
  • Systems are supported in remaining vertical space. The following table considers space requirements for the AlphaServer DS10 system boxes and RA3000.
  • For ballast requirements refer back to "Cabinet Configuration Chart for AlphaServer DS10 (3U) with StorageWorks Shelves (4U)."
   

M-series
Cabinet

System Rack Kit per DS10 system

M-series Cabinet Height/Space

AlphaServer DS10 Systems

StorageWorks

RA3000 + Shelves

H9A10-MC/MD

BA36R-RC/RD

54.2² / 32U

1

1 + 5

2

1 + 5

3

1 + 5

H9A15-MC/MD

BA36R-RC/RD

66.5² / 39U

2

1 + 5

2

1 + 5

3

1 + 5

4

1 + 5

    
Cabinet Configuration Chart for AlphaServer DS10 (3U) with StorageWorks BA370 (20U) and Disk Shelves
  • 20U of vertical cabinet space is reserved for one front-mounted BA370 rackmount enclosure, or one front-mounted and one rear-mounted BA370 enclosure in top of cabinet, front to back. Note that top fan (1U) is removed from cabinet when BA370 rackmount enclosure is installed.
  • Systems and StorageWorks shelves are supported in remaining vertical space; StorageWorks shelves are not supported in rear of cabinet behind a front-mounted BA370 rackmount enclosure.
   
Cabinet Configuration Rules for AlphaServer DS10 with BA370 and Disk Shelves

Cabinet

Cabinet Rack Kit
for BA370

Cabinet Height/Space

Systems

BA370 Enclosures

Shelves

H9A10-MC/MD

BA36R-RC/RD

54.2² / 32U

1

1 (front) or

2

2

2 (front & back)

0

H9A15-MC/MD

BA36R-RC/RD

66.5² / 40U

1

1 (front) or

6

2

2 (front & back)

4

3

   

0

Note: Installation of one BA370 and one system in H9A15 cabinet requires mandatory selection of a ballast kit; a ballast kit is not required if two BA370s and one system are installed in H9A15 cabinet.
  
M-series Rackmount Kit for AlphaServer DS10
  • Rackmount kit must be ordered separately
AlphaServer DS10 M-series rackmount kit

3X-PBX01-AB

   Note: Factory integration of a DS10 system drawer in a Compaq 9000 rackmount cabinet using rack kit, 3X-PBX01-AA, is not supported. Contact CustomSystems. 
M-series Cabinets 67² cabinet enclosure with 54.2² or 33U of usable vertical space; 120V dual-24A controller, each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P, Americas, Asia Pacific; includes rear door, top fan tray, and two H7600-AA power distribution units H9A10-MC
67² cabinet enclosure with 54.2² or 33U of usable vertical space; 240V dual-16 A controller, each with 12 IEC C13 outlets, input power plug IEC 309, 16A, Europe; includes rear door, top fan tray, and two H7600-DB power distribution units H9A10-M
79² cabinet enclosure with 66.5² or 40U of usable vertical space; 120V dual-24A controller, each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P, Americas, Asia Pacific; includes rear door, top fan tray, and two H7600-AA power distribution units

H9A15-MC

79² cabinet enclosure with 66.5² or 40U of usable vertical space; 240V dual-16A controller, each with 12 IEC C13 outlets, input power plug IEC 309, 16A, Europe; includes rear door, top fan tray, and two H7600-DB power distribution units

H9A15-MD

     
M-series Cabinet Rackmount Kit for AlphaServer DS10
  • Rackmount kit must be ordered separately
AlphaServer DS10 M-series rackmount kit

3X-PBX01-AB

Note: (Refer to the Cabinet Configuration Charts above for configuration rules.)
      
StorageWorks Shelves Supported in M-series Cabinets with Front Doors (H9A10/H9A15) StorageWorks UltraSCSI single bus, single-ended shelf with 180W power supply and RETMA mounting kit

BA36R-RC

StorageWorks UltraSCSI split bus, single-ended shelf with 180W power supply and RETMA mounting kit

BA36R-RD

180W power supply for redundant power of a BA36R (includes power cord)

CK-BA35X-HH

     
BA370 Rackmount Enclosure/Rear Cabinet Extender BA370 front-mount rackmount enclosure includes RETMA rackmount kit; first BA370 enclosure must be front mounted in cabinet, 20U height

2T-BA370-AS

BA370 rear-mount rackmount enclosure includes RETMA rackmount kit; second BA370 enclosure must be rear mounted in cabinet, 20U height

2T-BA370-AR

Note: Rear Cabinet Extender, H9C10-TE or H9C15-TE, is mandatory for second BA370
      
M-series Cabinet Rear Cabinet Extender Rear cabinet extender, top gun blue, for H9A10-MC/MD cabinets

H9C10-TE

Rear cabinet extender, top gun blue, for H9A15-MC/MD cabinets

H9C15-TE

     
M-series cabinet Front Door
  • Required selection of door based on cabinet height
Front door, top gun blue, for H9A11-MC/MD cabinet enclosure: selection of front door for H9A11 is optional, cabinet includes front trim kit and filler bezel

H9C11-EB

Front door, top gun blue, for H9A10-MC/MD cabinet enclosure

H9C10-TF

Front door, top gun blue, for H9A15-MC/MD cabinet enclosure

H9C15-TF

      
M-series Cabinet Factory Integration - Required Factory Integration of systems and storage devices assembled and configured in cabinet enclosure for H9A10 or H9A15 cabinet enclosures

YS-ASCAA-AA

     
M-series Cabinet Ballast Kits - As Required
  • Ballast is added to a cabinet at particular locations for specific configurations to meet safety regulations for installation, operation, and service; see Cabinet Configuration Charts
Two 35 to 40 lb/15.88 to 18.14 kg steel plates

H9C10-MC

     
M-series Cabinet Rackmount Power Cords
  • Required for BA370
US/Canada

BN20Z-4E

Non-US

BN35S-4E

Japan, 2.5m

3X-BN46D-4E

     
Compaq CustomSystems Support
  • Cabinets containing systems and storage must be assembled by qualified assemblers: Compaq Manufacturing, Compaq CustomSystems, or an authorized Compaq Certified Integration Partner.
  • For custom integration of systems, options, cabinet expansion offerings, and additional Compaq and third-party devices, or for other cabinets, doors, and trim kits of a different color, contact Compaq CustomSystems at 1-800-AT COMPAQ, or your local authorized Compaq Certified Integration Partner.
      
Step 6 - External Storage - Optional
UltraSCSI Configuration Rules
  • UltraSCSI configurations require UltraSCSI components (controllers, adapters, shelves, disks, and cables)
  • UltraSCSI adapters support UltraSCSI disks at UltraSCSI speeds in UltraSCSI top gun blue shelves (DS-BA356-xx)
UltraSCSI StorageWorks Pedestals
  • UltraSCSI top gun blue pedestals provide support for UltraSCSI disk drives; pedestal is available in single-bus or split-bus configurations and includes a personality module and 180W power supply
  • UltraSCSI shelf supports: seven 3.5² hard disk drives, or one 5.25² device and four 3.5² hard disk drives, or two 5.25² devices and one 3.5² hard disk drive
  • Installation of redundant power supply reduces number of 3.5² drive slots by one
UltraSCSI single-ended pedestal, single-bus personality module, 180W power supply

DS-BA356-KF

UltraSCSI single-ended pedestal, split-bus personality module, 180W power supply

DS-BA356-KG

UltraSCSI pedestal, single-channel differential personality module, 180W power supply

DS-BA356-KH

180W power supply, includes 120V North American and 240V IEC power cord

CK-BA35X-HH

 
Tabletop Tape Drives
  • Tape drives require an LVD adapter (3X-KZPCA-AA) or single-ended UltraSCSI adapter (KZPCM-DA) and country-specific power cord
12/24-GB 4-mm DAT narrow single-ended tabletop SCSI tape, includes 120V North American power cord, requires BN31W-xx SCSI cable

DS-TLZ10-DB

20/40-GB 4 mm DAT LVD tabletop SCSI tape drive - North America (Tru64 UNIX and OpenVMS only)

157770-001

20/40-GB 4 mm DAT LVD tabletop SCSI tape drive - International (Tru64 UNIX and OpenVMS only)

157770-B31

20/40-GB 4 mm DAT LVD tabletop SCSI tape drive - Japan (Tru64 UNIX and OpenVMS only)

157770-291

35/70-GB AIT LVD tabletop tape drive unit, US

216885-001

35/70-GB AIT LVD tabletop tape drive unit, International

216885-B31

35/70-GB AIT LVD tabletop tape drive unit, Japan

216885-291

50/100-GB 8mm AIT LVD tabletop SCSI tape drive - North America (Tru64 UNIX and OpenVMS only)

157767-001

50/100-GB 8mm AIT LVD tabletop SCSI tape drive - International (Tru64 UNIX and OpenVMS only)

157767-B31

50/100-GB 8mm AIT LVD tabletop SCSI tape drive - Japan (Tru64 UNIX and OpenVMS only)

157767-291

32/64-GB DAT loader in carrier (Tru64 UNIX and OpenVMS only)

TLZ9L-VA

32/64-GB tabletop DAT loader (Tru64 UNIX and OpenVMS only)

TLZ9L-DB

20/40-GB SCSI (DLT 4000E) tabletop tape drive (Tru64 UNIX and OpenVMS only)

TZ88N-TA

40/80-GB SCSI LVD (DLT8000) tabletop tape drive - Worldwide

146197-B21

40/80-GB SCSI LVD (DLT8000) tabletop tape drive - Japan

146197-291

110/220-GB SDLT Ultra2 LVD tabletop tape drive, US

192103-001

110/220-GB SDLT Ultra2 LVD tabletop tape drive, International

192103-B31

110/220-GB SDLT Ultra2 LVD tabletop tape drive, Japan

192103-291

       
Storage Controllers/Host Bus Adapters for StorageWorks Pedestals and Shelves
  • Storage controllers require a minimum Operating System Revision of Tru64 UNIX V4.0F or OpenVMS V7.1-2 unless noted otherwise.
  • Each storage controller/adapter uses one PCI slot
       
  

Maximum # Supported

 
  

Tru64 UNIX

OpenVMS

Linux-Ready

  
PCI-to-Fibre Channel host bus adapter

2

2

-

DS-KGPSA-CA

Fibre Channel cable xx=02, 05, 15, 30, 50 meters      

BNGBX-xx

   
PCI-to-Fibre Channel 64-bit adapter, HBA

-

-

2

DS-SWLA4-PD

   
PCI 2-port UltraSCSI single-ended adapter and 10/100 Mb Ethernet combo adapter

2

2

2

KZPCM-DA

VHDCI male-to-VHDCI male UltraSCSI cable,
xx=02, 2E (2.5), 03, 05, 10, 20 m)
     

BN37A-xx

    
PCI 1-port Ultra2 SCSI (LVD) adapter, 68-pin HD connector, requires BN38C cable (2 to 20m) to connect to single-ended UltraSCSI or LVD shelf

2

2

3

3X-KZPCA-AA

68-pin HD male-to-VHDCI male UltraSCSI cable; required for each external UltraSCSI shelf attached to KZPCA-AA adapter      

BN38C-xx

    
PCI 2-channel LVD multi-mode Ultra3 SCSI adapter, VHDCI
Note: Patch kit required, kit is available at http://ftp1.support.compaq.com/
public/Digital_UNIX/v5.1/

1

V5.1

-

-

3X-KZPEA-DB

PCI 1-port UltraSCSI differential adapter; includes external 68-pin HD connector; requires BN38C-xx cable (2-25m) to connect adapter to Differential UltraSCSI shelf or RAID controller

2

2

2

KZPBA-CB

68-pin HD male-to-VHDCI male UltraSCSI cable; required for each external UltraSCSI shelf attached to KZPBA-CB adapter      

BN38C-xx

     
PCI 3-channel Ultra2 LVD RAID controller, 64-bit, 64-MB cache

2

V4.0F/4.0G/5.1

-

-

DS-KZPCC-CE

PCI 1-channel Ultra2 LVD backplane RAID controller, 64-bit, 16-MB cache

2

V4.0F/4.0G/5.1

-

-

DS-KZPCC-AC

      
PCI 1-port UltraSCSI RAID controller with 4-MB cache memory, includes RAID Array 230/Plus Subsystem software and documentation kit and VHDCI female connector; tape drives not supported - 18.2-GB or higher disk drives not supported on KZPAC-xx RAID controllers

2

V4.0F

2

-

KZPAC-AA

PCI 3-port UltraSCSI RAID controller with 4-MB cache memory, includes RAID Array 230/Plus Subsystem Software and documentation kit; tape drives not supported; SCSI cable required for each active port; requires BN31K-0E for external third-port connection - 18.2-GB or higher disk drives not supported on KZPAC-xx RAID controllers

2

V4.0F

2

-

KZPAC-CA

PCI 3-port UltraSCSI RAID controller with 8-MB cache memory, includes RAID Array 230/Plus Subsystem Software and documentation kit; tape drives not supported; SCSI cable required for each active port; requires BN31K-0E for external third-port connection - 18.2-GB or higher disk drives not supported on KZPAC-xx RAID controllers

2

V4.0F

2

-

KZPAC-CB

Cache battery backup for KZPAC controller      

KZPSC-UB

VHDCI male-to-VHDCI male UltraSCSI cable, xx=02, 2E (2.5), 03, 05, 10, 20 m)
Note: Manufacturing may substitute BN37A-02 cable for specific cabinet configurations
     

BN37A-xx

SCSI cable/bulkhead assembly kit with KZPAC-CA/CB, allows external connection of one third port      

BN31K-0E

SCSI cable/bulkhead assembly kit with two ports for KZPAC-CA/CB, allows external connection of two third ports      

KZPAC-SB

    
PCI 1-channel Ultra2 SCSI RAID controller, 4-MB cache (Linux-Ready systems only)

-

-

3

SN-KZPBC-AA

PCI 3-channel Ultra2 SCSI RAID controller, 32-MB cache (Linux-Ready systems only)

-

-

3

FR-PCTAR-IB

PCI 3-channel Ultra2 SCSI RAID controller, 64-MB cache (Linux-Ready systems only)

-

-

3

FR-PCTAR-IC

         
StorageWorks Fibre Channel Switches Fibre Channel SAN Switch, 8 ports with Fabric Operating Software (DS-DSGGB-AA)

158222-B21

Fibre Channel SAN Switch, 16 ports with Fabric Operating Software (DS-DSGGB-AB)

158223-B21

Note: For above switches, refer to http://www.compaq.com/products/
quickspecs/10457_na/10457_na.HTML
for more information
Fibre Channel SAN Switch 8-EL (DS-DSGGC-AA) – refer to http://www.compaq.com/products/
quickspecs/10647_na/10647_na.HTML
for more information

176219-B21

Fibre Channel SAN Switch 16-EL (DS-DSGGC-AB) – refer to http://www.compaq.com/products/
quickspecs/10735_na/10735_na.HTML
for more information

212776-B21

      
StorageWorks BA370 Rackmount Enclosure
  • M-series cabinets (H9A10 and H9A15) allow one BA370 enclosure to be installed in front cabinet
  • Host adapter, RAID Array controller, platform specific Solutions Software Kit, and disk drives must be ordered separately
BA370 front mount rackmount enclosure with five 180W power supplies, includes RETMA rackmount kit; first BA370 enclosure must be front mounted in cabinet, 20U height

2T-BA370-AS

Factory configured RAID of rackmounted BA370/HSZ80

YS-ASCRD-AA

Note: Factory configured RAID sets for disks in rackmounted BA370 StorageWorks shelf controlled by one or two HSZ70s require completion of questionnaire located at http://www.digital.com/alphaserver/fcr
        
Removable Media Devices for External StorageWorks Shelves 12/24-GB 4 mm DAT narrow SCSI tape drive in StorageWorks carrier

DS-TLZ10-VA

20/40-GB DLT tape drive in StorageWorks carrier (Tru64 UNIX and OpenVMS only)

TZ88N-VA

40/80-GB DLT tape drive in StorageWorks carrier

DS-TZ90N-VW

35/70-GB AIT tape drive in StorageWorks carrier (Tru64 UNIX and OpenVMS only)

DS-AIT35-VW

600-MB 32X SCSI CD-ROM drive in StorageWorks carrier

DS-RRD47-VA

     
StorageWorks UltraSCSI Shelves
  • Requires selection of UltraSCSI adapter and SCSI cable
  • StorageWorks Shelf supports seven 3.5" x 1.6" hard disk drives; with the addition of redundant power supply, six drives are supported
  • StorageWorks shelf kits are mounted back-to-back in pedestals and cabinets
StorageWorks UltraSCSI single-bus shelf kit

BA36R-RC

StorageWorks UltraSCSI split-bus shelf kit

BA36R-RD

3-m SCSI cable

BN37A-03

Disk Drives (Supported in StorageWorks UltraSCSI Shelves)
  • Maximum six (10,000 rpm) or seven (7,200 rpm) drives supported in StorageWorks shelf
  • One power supply supports a maximum of six 10,000 rpm disks
9.1-GB UltraSCSI drive 7,200 rpm

DS-RZ1DA-VW

9.1-GB UltraSCSI drive 10,000 rpm

DS-RZ1DD-VW

18.2-GB UltraSCSI drive 7,200 rpm

DS-RZ1EA-VW

18.2-GB UltraSCSI drive 10,000 rpm

DS-RZ1ED-VW

36.4-GB UltraSCSI drive 10,000 rpm

DS-RZ1FC-VW

StorageWorks Universal Drive Shelves – Model 4314R (Ultra3) StorageWorks Model 4314R Ultra3 rackmount, single bus, US

DS-SL13R-AA

Same as above, International

DS-SL13R-AB

Same as above, Japan

DS-SL13R-AJ

StorageWorks Universal Drive Shelves – Model 4354R (Ultra3) StorageWorks Model 4354R Ultra3 rackmount, dual bus, US

DS-SL13R-BA

Same as above, International

DS-SL13R-BB

Same as above, Japan

DS-SL13R-BJ

StorageWorks Universal Drive Shelves Single Bus – Model 4314T Tower (Ultra3) StorageWorks Model 4314T, Ultra3, Universal Drive Shelves Single Bus, Tower, US

DS-SL13T-AA

StorageWorks Model 4314T, Ultra3, Universal Drive Shelves Single Bus, Tower, International

DS-SL13T-AB

StorageWorks Model 4314T, Ultra3, Universal Drive Shelves Single Bus, Tower, Japan

DS-SL13T-AJ

StorageWorks Universal Drive Shelves – Model 4200 to Model 4300 Upgrade I/O Modules StorageWorks Model 4300 Ultra 160 single-port LVD I/O Module

DS-SE3ZJ-DA

StorageWorks Model 4300 Ultra 160 dual-port LVD I/O Module

DS-SE3ZJ-SA

System Disk Drives (Supported in Model 4254, 4314R, 4354R Universal Drive Shelves) 9.1-GB Ultra3 (LVD) 10,000 rpm 1.0² Universal drive

3R-A0584-AA

9.1-GB Ultra3 (LVD) 15,000 rpm 1.0² Universal drive

3R-A1542-AA

18.2-GB Ultra3 (LVD) 15,000 rpm 1.0² Universal drive

3R-A1543-AA

36.4-GB Ultra3 (LVD) 10,000 rpm 1.0² Universal drive

3R-A0919-AA

18.2-GB Ultra 3 SCSI, 10,000 RPM 1.0" Universal Drive

3R-A0585-AA

72.8-GB Ultra 3 SCSI, 10,000 RPM 1.0" Universal Drive

3R-A3050-AA

Step 7 - UltraSCSI RAID Array Controllers and UltraSCSI RAID Packaged Solutions - Optional
RAID Array 3000 Rackmount Controller Shelf
  • Selection of RA3000 Solutions Software Kit is required
  • Supported SCSI adapter - KZPBA-CB PCI 1-port UltraSCSI differential adapter
RA3000 rackmount controller shelf, blue, with one controller, 110V
Includes: UltraSCSI BA356 controller shelf, one HSZ22 2-channel controller with 16-MB cache, integrated Environmental Monitoring Unit (EMU), two 180W power supplies, two dual-port host differential UltraSCSI I/O SBBs, dual-channel UltraSCSI single-ended personality modules, one 120V 1000VA rackmount UPS, 5-m host SCSI cable (BN37A-05), BN38E-0B adapter, UPS serial cable, PC connection serial cable (DB-9), two 68-pin HD tri-link adapters (H8861-AA), two North American power cords, and RETMA mounting bracket (disk shelves and disks not included)
Requires: Solutions Software Kit for platform, host adapter, RA3000 disk shelf, and disks
Options: Second HSZ22 controller, up to four additional RA3000 disk shelves, cache memory upgrade

DS-SWXRA-GH

RA3000 rackmount controller shelf, blue, with one controller, 230V
Includes: UltraSCSI BA356 controller shelf, one HSZ22 2-channel controller with 16-MB cache, integrated Environmental Monitoring Unit (EMU), two 180W power supplies, two dual-port host differential UltraSCSI I/O SBBs, dual-channel UltraSCSI single-ended personality modules, one 230V 1000VA rackmount UPS, 5-m host SCSI cable (BN37A-05), BN38E-0B adapter, UPS serial cable, PC connection serial cable (DB-9), two 68-pin HD tri-link adapters (H8861-AA), RETMA mounting bracket (disk shelves and disks not included)
Requires: Solutions Software Kit for platform, two country-specific power cords, host adapter, RA3000 disk shelf, and disks
Options: Second HSZ22 controller, up to four additional RA3000 disk shelves, cache memory upgrade

DS-SWXRA-GK

       
RAID Array 3000 Rackmount
Disk Shelf
  • Select one to four disk shelves
  • Third and fourth DS-SWXRA-GN disk shelf ordered will be installed in rear of M-series cabinet; rear mounted shelves require that a 2-m BN37A-02 SCSI cable be ordered
RA3000 rackmount disk shelf, blue, includes UltraSCSI BA356 disk shelf, two 180W power supplies, single-ended UltraSCSI personality card, one half meter SCSI cable (BN37A-0E), two North American power cords, and RETMA mounting bracket (disks not included); order two country-specific power cords for non-North American use

DS-SWXRA-GN

        
HSZ22 Controller
  • Note that second HSZ22 controller ordered is field installed only, not factory installed; requires BN37A-0E SCSI jumper cable be ordered separately
Second HSZ22 controller with 16-MB cache and two 16-MB SIMMs for mirror cache, one BN37A-05 5-m UltraSCSI cable, one BN38E-0B cable adapter - field installable only; note that second HSZ22 controller does not require additional Solution Software Kit

DS-HSZ22-AA

Second HSZ22 controller with 32-MB cache and two 32-MB SIMMs for mirror cache, one BN37A-05 5-m UltraSCSI cable, one BN38E-0B cable adapter - field installed only; note that second HSZ22 controller does not require additional Solution Software Kit

DS-HSZ22-AB

        
RA3000 Solutions Software Kit
  • StorageWorks Command Console (SWCC) software
  • Platform specific software
  • Installation scripts and installation documentation
RA3000 Solutions Software Kit for Tru64 UNIX

QB-5TWAB-SA

RA3000 Solutions Software Kit for OpenVMS

QB-5TWAC-SA

       
HSG80/HSZ80 External Controllers Fibre Channel controller (DS-HSG80-BJ), includes 2-MB cache expandable to 128 MB; requires 128697-B21 HSG80 ACS V8.4F software kit or 128698-B21 V8.4P software kit for each HSG80 ordered

380672-B21

Fibre Channel controller (DS-HSG80-BH), includes 64-MB cache expandable to 128 MB; requires 128697-B21 HSG80 ACS V8.4F software kit or 128698-B21 V8.4P software kit for each HSG80 ordered

380671-B21

UltraSCSI controller (DS-HSZ80-AH), includes 64-MB cache expandable to 128 MB; requires 400569-001 for Tru64 UNIX or 400571-001 for OpenVMS

400564-B21

UltraSCSI controller (DS-HSZ80-AJ), includes 256-MB cache expandable to 512 MB; requires 400569-001 for Tru64 UNIX or 400571-001 for OpenVMS

400565-B21

        
ESA 10000, RAID Array 7000, RAID Array 8000
  • Enterprise Storage Array 10000 and RAID Array 7000 (HSZ70) product set are supported on AlphaServer DS10 systems
  • Supported SCSI adapter for HSZ80/HSZ70 - KZPBA-CB PCI 1-port UltraSCSI differential adapter
  • Supported SCSI adapter for HSG80 - KGPSA-BC PCI 1-port Fiber-Channel adapter
        
Step 8 - Graphics Adapters - Optional
  • RAID Configuration Utility is accessible via console port for Tru64 UNIX and OpenVMS systems; optional graphics capability available
  • Select graphics adapter, monitor, and country-specific keyboard if required
      
   

Maximum # Supported

   
   

Tru64 UNIX

OpenVMS

Linux-Ready

   
3Dlabs Oxygen VX1 32-MB PCI 2D graphics accelerator 3 3 -

SN-PBXGF-AB

ELSA Gloria synergy graphics with 8-MB SGRAM 1600 x 1200, 2D/3D graphics accelerator

3

3

1

SN-PBXGK-BB

PowerStorm 300 3D multi-head graphics accelerator with 15-MB frame buffer memory and 16-MB texture memory

3

3

-

SN-PBXGD-AD

PowerStorm 350 3D multi-head graphics accelerator with 30-MB frame buffer memory and 32-MB texture memory

3

3

-

SN-PBXGD-AE

PCI combo adapter, Permedia P2 graphics, 10/100 Mbit NIC

1

1

1

3X-DEPVD-AA

PCI combo adapter, Permedia P2 graphics, 10/100 NIC, 1-port SCSI 1 1 -

3X-DEPVZ-AA

Ensonig PCI 1373 audio card with headphone jack and CD audio cable

1

1

-

SN-AVH10-AC

   
Step 9 - Monitors - Optional
  • Graphics monitors other than those listed below can be used if compatible with SVGA graphics ordered with system
  • Monitors ship with, but are not integrated with the system.
V570 15" (13.8" viewable image size) multiple-scan color monitor, VGA to 800 x 600 @85 Hz, 0.28mm AG, TCO99, Northern Hemisphere with NA power cord

3R-A3082-AA

Same as above with Eurocord

3R-A3083-AA

Same as above, APD, no power cord

3R-A3084-AA

        
V500 15" (13.8" viewable image size) auto scanning color monitor, VGA to 1024 x 768 @85 Hz, 0.28mm FST, MPRII, Southern Hemisphere with Australia/New Zealand power cord

3R-VRQV5-11

        
P710 17" (16" viewable image size) auto-scanning color monitor, Diamondtron NF, 0.25mm aperture grille pitch, VGA to 1280 x 1024 @ 75 Hz, TCO 99; Northern Hemisphere with NA power cord

3R-A2936-AA

Same as above, APD, no power cord

3R-A2260-AA

Same as above, PRC with power cord, CCIB

3R-A3335-AA

Same as above, Southern Hemisphere, with Australia/New Zealand power cord

3R-A2263-AA

Same as above, Northern Hemisphere, with Power Factor Correction and Eurocord, 220V only

3R-A2261-AA

        
TFT 8020 18" (18.1" viewable image size) flat panel monitor, TFT active matrix, in-plane switching technology 160 degrees viewing angles, 1280 x 1024 resolution, brightness 200 nits, detachable base; requires ELSA GLoria Synergy or PowerStorm 3xx video adapter

3R-A0852-AA

        
P910 19" (18" viewable image size) auto-scanning color monitor, Diamondtron NF, 0.25mm aperture grille pitch, VGA to 1280 x 1024 @ 85 Hz, TCO 99; Northern Hemisphere with NA power cord

3R-A2935-AA

Same as above, PRC with power cord, CCIB

3R-A3334-AA

Same as above, Southern Hemisphere, with Australia/New Zealand power cord

3R-A2267-AA

Same as above, Northern Hemisphere, with power factor correction and Eurocord, 220V only

3R-A2265-AA

        
P1100 21" (19.6" viewable image size) auto-scanning color monitor, Trinitron CRT, 0.28mm aperture grille pitch, VGA to 1600 x 1200 @75Hz, TCO99, Southern Hemisphere, Australia/New Zealand power cord

3R-VRQP1-23

        
P1210 22" (20" viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24mm aperture grille pitch, VGA to 1600 x 1200 @ 85 Hz, TCO 99 with power factor correction, Northern Hemisphere with NA power cord

3R-A2934-AA

Same as above with Eurocord

3R-VRQP2-AA

Same as above, PRC with power cord, CCIB

3R-A3333-AA

Same as above, APD, no power cord

3R-A2268-AA

        
Video Extension Cable Each monitor includes a 1.8-m signal cable - video extension cable required for most server applications

BN39C-02

        
Monitor Power Cords Australia, New Zealand, 2.5 m

BN19H-2E

Central Europe, 2.5 m

BN19C-2E

Denmark, 2.5 m

BN19K-2E

Egypt, India, South Africa, 2.5 m

BN19S-2E

Israel, 2.5 m

BN18L-2E

Italy, 2.5 m

BN19M-2E

Japan, 2.5 m, Dentori approved

3X-BN46F-02

North America

BN26J-1K

Switzerland, 2.5 m

BN19E-2E

UK, Ireland, 2.5 m

BN19A-2E

        
Step 10 - Networks and Communications - Optional
  • Controllers/adapters require a minimum of Tru64 UNIX V4.0F or OpenVMS V7.1-2.
  • Systems include dual embedded 10/100 BaseT Ethernet ports (BN25G-xx cable must be ordered separately)
  • Additional Ethernet ports can be added using available PCI slots
   
  

Maximum # Supported

  
  

Tru64 UNIX

OpenVMS

Linux-Ready

  
PCI 1-port 10/100-Mb Ethernet adapter (Twisted Pair

1

-

1

3X-DE600-AA

PCI to dual-port 10/100 UTP Fast Ethernet adapter

1

V4.0F

1

1

3X-DE602-AA

 
PCI single-port MMF add-on daughter card for 3X-DE602-AA

1

1

 

3X-DE602-FA

PCI 10/100 Mbit 4-port Ethernet adapter, UTP

1

1

1

DE504-BA

Cable for 10BaseT twisted pair connection      

BN25G-xx

 
PCI Gigabit Ethernet adapter, SC connectors, MMF, no boot support

1

1

1

DEGPA-SA

SC-to-SC dual fiber optic cable      

BN34B-xx

 
PCI combo adapter, Permedia P2 graphics, 10/100 Mbit NIC

1

1

1

3X-DEPVD-AA

PCI combo adapter, Permedia P2 graphics, 10/100 NIC, 1-port SCSI

1

1

-

3X-DEPVZ-AA

 
PCI FDDI adapter, single attachment station (SAS), multi-mode fiber (MMF), SC connector

1

1

-

3X-DEFPA-AC

PCI FDDI adapter, DAS, MMF, SC connector

1

1

-

3X-DEFPA-DC

MIC-SC dual fiber optic cable mm, pp xx = length in meters      

BN34D-xx

SC-to-SC dual fiber optic cable mm, pp xx = length in meters      

BN34B-xx

PCI FDDI adapter, SAS, TP-PMD, requires BN25H-03 cable

1

1

-

3X-DEFPA-UC

PCI FDDI dual adapter, DAS, TP-PMD, requires BN25H-03 cable

1

1

-

3X-DEFPA-MC

3m (9.8") FDDI cross-over cable mm, pp xx = length in meters      

BN25H-03

  
PCI 4-port asynchronous controller, cable included; maximum three PBXDA-Ax per system

3
V4.0F

3

-

PBXDA-AA

PCI 8-port asynchronous controller, cable included; maximum three PBXDA-Ax per system

3
V4.0F

3

-

PBXDA-AB

PCI 16-port asynchronous controller, cable included; maximum three PBXDA-Ax per system

3
V4.0F

3

-

PBXDA-AC

PCI-to-ATM 155 Mb adapter - Fiber

2
V4.0F

2
V7.2-1

-

3X-DAPBA-FA

PCI-to-ATM 155 Mb adapter - UTP

2
V4.0F

2
V7.2-1

-

3X-DAPBA-UA

PCI-to-ATM 622 Mb adapter - Fiber

1
V4.0F

2
V7.2-1

-

3X-DAPCA-FA

PCI-to Gigabit Ethernet adapter-UTP, with RJ45 1 - 1 DEGPA-TA
PCI-to-dual port synchronous controller - 2 - 3X-PBXDD-AA
PCI-to-quad port synchronous controller - 2 - 3X-PBXDD-AB
      
Step 11 - Keyboards, Mouse
Step 11a - Keyboards
  • Keyboards are not included with the system and must be ordered separately
  • Selection of country-specific keyboard is recommended.

Tru64 UNIX

OpenVMS

U.S./English keyboard

SN-LKQ47-BA

LK461-A2

Arabic keyboard

SN-LKQ47-BR

-

Belgian keyboard

SN-LKQ47-AB

LK461-AB

BHCSY keyboard

SN-LKQ47-AX

-

Canadian/English keyboard

-

LK461-AQ

Canadian/French keyboard

SN-LKQ47-AC

LK461-AC

Cyrillic keyboard

SN-LKQ47-BT

LK461-BT

Czech keyboard

SN-LKQ47-BV

LK461-BV

Danish keyboard

SN-LKQ47-AD

LK461-AD

Dutch keyboard

SN-LKQ47-AH

LK461-AH

Finnish keyboard

SN-LKQ47-AF

LK461-AF

French keyboard

SN-LKQ47-AP

LK461-AP

German keyboard

SN-LKQ47-AG

LK461-AG

Greek keyboard

SN-LKQ47-BH

LK461-BH

Hebrew keyboard

SN-LKQ47-AT

LK461-AT

Hungarian keyboard

SN-LKQ47-BQ

LK461-BQ

Italian keyboard

SN-LKQ47-AI

LK461-AI

Korean keyboard

SN-LKQ47-BK

-

Latin-American keyboard

SN-LKQ47-AR

-

Norwegian keyboard

SN-LKQ47-AN

LK461-AN

Polish keyboard

SN-LKQ47-BP

LK461-BP

Portuguese keyboard

SN-LKQ47-AV

LK461-AV

Romanian keyboard

-

LK461-BL

S. Chinese keyboard

SN-LKQ47-CV

-

Slovak keyboard

SN-LKQ47-CZ

LK461-CZ

Spanish keyboard

SN-LKQ47-AS

LK461-AS

Swedish keyboard

SN-LKQ47-AM

LK461-AM

Swiss/French keyboard

SN-LKQ47-AK

LK461-AK

Swiss/German keyboard

-

LK461-AL

Taiwanese keyboard

SN-LKQ47-BI

-

Thai keyboard

SN-LKQ47-CB

-

Turkish keyboard

SN-LKQ47-BU

LK461-BU

Turkish/French keyboard

-

LK461-BW

UK keyboard

SN-LKQ47-AE

-

Yugoslavian keyboard

-

LK461-BY

   
Step 11b - Mouse – Recommended
3-button mouse

SN-PBQWS-WA

        
Step 12 - MEMORY CHANNEL - Optional
Tru64 UNIX Systems
  • Requires Tru64 UNIX V5.0A or later and either TruCluster Server License
    (QL--6BRAC-AA or TruCluster Plus Software Package (QP-6R9AC-AA)
OpenVMS Systems
  • Requires OpenVMS V7.1-2 or later and OpenVMS Cluster license
    (QL-MUZAE-AA)
     
Configuring Information
  • Up to one PCI to System Area Network adapters (CCMAB-AA) are supported in a single system
  • Two-node clusters can be configured by ordering a CCMAB-AA for each system and one BN29B-04 or
    BN29B-10 cable; the cable connects directly to the CCMAB-AA in each system
  • For three or four system nodes, order one CCMAB-AA adapter, one BN29B-04 or BN29B-10 cable and one CCMHB-AA; make connections from the CCMAB-AA in a system to the CCMHB-AA
  • CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up to eight system nodes can be achieved by adding up to four additional CCMLB-AA line cards
  • For integration of MEMORY CHANNEL hubs into cabinet configurations, a rackmount kit (2T-MAVRK-AA) and power cord (BN35S-02) are required
           
MEMORY CHANNEL Controller PCI System Area Network Controller, maximum two

CCMAB-AA

System Area Network Hub with four line cards; includes BN19P-2E power cord for Canada, Japan, and US operations- for other regions, order appropriate power cord from list below

CCMHB-AA

Expansion line card for CCMHB hub

CCMLB-AA

1-m cable for CCMAB and CCMHB

BN39B-01

4-m cable for CCMAB and CCMHB

BN39B-04

10-m cable for CCMAB and CCMHB

BN39B-10

Rackmount kit for CCMHB hub

2T-MAVRK-AA

Power cord for rackmount CCMHB hub

BN35S-02

      
MEMORY CHANNEL Power Cords Australia, New Zealand

BN19H-2E

Central Europe

BN19C-2E

Denmark

BN19K-2E

Egypt, India

BN19S-2E

Ireland, United Kingdom

BN19A-2E

Israel

BN18L-2E

Italy

BN19M-2E

Switzerland

BN19E-2E

        
Step 13 - Floor Stand
Floor Stand for AlphaServer/AlphaStation DS10

3X-BA73P-AA

     
Step 14 - Software - Required selection of media and online documentation kit for first system on site
  • Software Processor Code = E
Tru64 UNIX
  • AlphaServer DS10Tru64 UNIX systems include Base license, Unlimited User license, Server Extension license, Internet Express, iPlanet Directory Server, iPlanet Enterprise Server, and Compaq Secure Web Server.
 
  • AlphaStation DS10 Tru Unix systems include 2-user Base license and Compaq Open3D traditional License

 

When using Tru64 UNIX V5.0 or later Tru64 UNIX media and online documentation on CD-ROM

QA-6ADAA-H8

Tru64 UNIX full hard copy documentation

QA-6ADAA-GZ

StorageWorks Software Package with licenses for Logical Storage Manager and AdvFS Utilities

QB-5RXAE-AA

TruCluster Server License

QL-6BRAC-AA

Advanced Server for Tru64 UNIX, 25 client concurrent use license

QL-5U29M-3D

Advanced Server for Tru64 UNIX, 50 client concurrent use license

QL-5U29M-3E

Advanced Server for Tru64 UNIX, 100 client concurrent use license

QL-5U29M-3F

Advanced Server for Tru64 UNIX, 250 client concurrent use license

QL-5U29M-3G

Advanced Server for Tru64 UNIX, 500 client concurrent use license

QL-5U29M-3H

Layered products media and documentation for Tru64 UNIX on CD-ROM

QA-054AA-H8

DECnet/OSI end-system license for Tru64 UNIX

QL-MTJAE-AA

DECnet/OSI extended function license for Tru64 UNIX

QL-MTKAE-AA

Open3D for Tru64 UNIX on CD-ROM, includes graphics drivers

QA-0AFAA-H8

     
OpenVMS
  • AlphaServer DS10 OpenVMS systems include Base license with System Manager license and Compaq Enterprise Integration Server License Package for OpenVMS Revision V3.0A.
  • AlphaStation DS10 OpenVMS systems include Base license, Concurrent Use 1-user license, NAS 150 Client license, and Compaq Open3D traditional license.
  • Compaq Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS, DECwindows Motif for OpenVMS Alpha, DECprint Supervisor for OpenVMS Alpha Plus, DECprint Supervisor for OpenVMS Open, DECnet-Plus for OpenVMS Alpha End System, Archive/Backup System for OpenVMS Management Tools, Archive/Backup Agent for Windows NT, OpenVMS Disk Services for Windows NT, Office Server for OpenVMS, PATHWORKS 32, PATHWORKS V6 for OpenVMS – Advanced Server, and DIGITAL Office Server Client Access License
OpenVMS V7.1-2 media and online documentation on CD-ROM

QA-MT1AR-H8

OpenVMS V7.2-1 media and online documentation on CD-ROM

QA-MT1AT-H8

OpenVMS media and online documentation on CD-ROM

QA-MT1AA-H8

OpenVMS hard copy documentation

QA-001AA-GZ

Layered products media and documentation for OpenVMS on CD-ROM

QA-03XAA-H8

Open3D for OpenVMS on CD-ROM, includes graphics drivers

QA-0ADAA-H8

  • OpenVMS Concurrent Use licenses provide the right to interactively use the operating system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS Concurrent Use licenses can be moved from one system to another at user discretion and can be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster.
  • OpenVMS Traditional Unlimited Use license is system specific and can only be used on one single system at a time. It cannot be shared between systems or in an OpenVMS VAX or OpenVMS Alpha Cluster.
Concurrent Use 1-user license

QL-MT3AA-3B

Concurrent Use 2-user license

QL-MT3AA-3C

Concurrent Use 4-user license

QL-MT3AA-3D

Concurrent Use 8-user license

QL-MT3AA-3E

Concurrent Use 16-user license

QL-MT3AA-3F

Concurrent Use 32-user license

QL-MT3AA-3G

Concurrent Use 64-user license

QL-MT3AA-3H

Concurrent Use 128-user license

QL-MT3AA-3J

Concurrent Use 256-user license

QL-MT3AA-3K

Traditional Unlimited User license

QL-MT2AE-AA

OpenVMS Cluster license for Alpha systems

QL-MUZAC-AA

OpenVMS Cluster Client license for Alpha systems

QL-3MRAC-AA

OpenVMS Cluster Client-to-Full OpenVMS Cluster Migration- license

QL-6J7AC-AA

     
Step 15 - Hardware and Software Support Services
  • Select one of the optional CarePaq Priority Service Packages described below that best supports the customer’s operational requirements for system availability.
CarePaq Priority Services
  • CarePaq Priority Services are available for Compaq AlphaServer/AlphaStation systems running Compaq Tru64 UNIX or OpenVMS operating systems. Priority Services are designed for the growing number of customers who need support beyond the basic warranty. Five packages are offered - Priority, Priority 24, Priority Silver, Priority Gold, and Priority Executive with coverage for both Principal servers/stations and SSPs (Subsequent System Packages) - that meet a full range of customer support requirements.
    
Program Features – Principal Server/Station
Priority
  • 9x5 HW/SW support
  • 4-hour response on-site hardware support
  • 2-hour response for Bronze software support
  • License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Condist update distribution for OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on Condist can be ordered separately.)
   
Priority 24
  • 24x7 HW/SW support
  • Named HW engineer
  • 4-hour response on-site hardware support
  • 2-hour response for Bronze software support
  • License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Condist update distribution for OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on Condist can be ordered separately.)
Priority Silver
  • 24x7 HW Support with Named Engineer, 4-hour response
  • 24x7 Silver SW Support - Named Account Rep, 1-hour response Monday – Friday, 8AM-5PM local time; 2-hour response remaining hours
  • License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Condist update distribution for OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on Condist can be ordered separately.)
  • Technical newsletter and SW activity review
  • Proactive Patch Notification
  • One (1) System Healthcheck per year
   
Priority Gold
  • 24x7 HW support with Named Engineer, 4-hour response for on-site support
  • 24x7 Gold SW support - Named Account Rep
  • 30-minute callback (critical); 1-hour callback (non-critical)
  • License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Condist update distribution for OpenVMS or Tru64 UNIX and their layered products. (Layered products not included on Condist can be ordered separately.)
  • Technical newsletter, SW activity review and 10 hours Upgrade impact planning
  • Proactive Revision Management
  • Two (2) System Healthchecks per year
  • Mandatory pre-qualification required
       
Priority Gold Executive
  • 24x7 HW support with Named Engineer, two-hour response for on-site support
  • 24x7 Gold SW support - Named Account Rep
  • 30-minute callback (critical); one-hour callback (non-critical)
  • License Subscription for Compaq O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Software update distribution on CD-ROM: OpenVMS or Tru64 UNIX and their layered products (Layered products not included on Condist can be ordered separately.)
  • Technical newsletter, SW activity review and 10 hours Upgrade impact planning
  • Proactive Revision Management
  • Two (2) System Healthchecks per year
  • Customer site must be within 25 miles of a Compaq service location
  • Mandatory pre-qualification required
     
Program Features – Additional Services
SSPs (Subsequent System Packages)
  • For Priority, Priority 24, Priority Silver, Priority Gold, and Priority Gold Executive
  • HW Support at same level as corresponding package for Principal server/station
  • License Subscription: Compaq O/S (where applicable)
  • Telephone support through Principal server/station covered by full support package
    
Installation
  • Pre-installation review
  • Unpacking of equipment
  • Assemble and test
  • Basic product usage info
  • No software installation added
   
Installation & Startup Compaq O/S
  • Pre-installation review
  • Unpacking of equipment
  • Assemble and test
  • Basic product usage info
  • Install operating systems
  • Product configuration
  • Print and network access
  • Orientation
   
Model/CarePaq
Priority Service

Principal Server
1 year

Principal Server
3 years

Subsequent Systems
1 year

Subsequent Systems
3 years

AlphaServer/AlphaStation DS10
Priority

FP-A01BA-12

FP-A01BA-36

FP-A21BA-12

FP-A21BA-36

Priority 24

FP-A02BA –12

FP-A02BA-36

FP-A22BA-12

FP-A22BA-36

Priority Silver

FP-A04BA-12

FP-A04BA-36

FP-A24BA-12

FP-A24BA-36

Priority Gold

FP-A08BA-12

FP-A08BA-36

FP-A28BA-12

FP-A28BA-36

Priority Gold Exec.

FP-A09BA-12

FP-A09BA-36

FP-A29BA-12

FP-A29BA-36

Installation

FP-AINST-BA

FP-AINST-BA

FP-AINST-BA

FP-AINST-BA

Installation & Startup

FP-ASTAR-BA

FP-ASTAR-BA

FP-ASTAR-BA

FP-ASTAR-BA

   
Notes:
  • AlphaServer/AlphaStation DS10 systems include three years hardware warranty with 5x9, on-site Next Business Day response.
  • New Compaq hardware options internal to the AlphaServer/AlphaStation enclosure receive the same warranty or service level as purchased with the server or station.
  • External storage devices/cabinets carry their own level of warranty and should be quoted separately for uplifted warranty services (CarePaq Priority Service).
  • In addition to the CarePaq Priority Services, uplifted warranty Supplemental Services are available for separate hardware and software support. For more information on Hardware and Software Supplemental Services and other Compaq service options available for AlphaServers and AlphaStations, consult your Compaq Sales Account Manager or visit http://www.compaq.com/services/
contents
 Overview   Standard Features   Systems/Options   Options   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) TechSpecs
    
Physical Characteristics Dimensions (HxWxD) 5.1 x 17.6 x 19 in/13 x 45 x 48 cm
Weight 36 lbs/16.3 kg
   
System Unit Environmental
Temperature Operating
(Tower, Rackmount)
50° to 104° F/10° to 40° C
Note: Maximum operating temperature at sea level. Reduce by 1.8° F (1° C) for each 2,000 ft (660 m) above sea level.
Non-operating –40° to 151° F/–40° to 66° C
Humidity Operating 10% to 95%
Non-operating 20% to 80%
Heat Dissipation Single unit = 176 Watts = 601 BTU/Hr
Rack of 12 systems = 2112 Watts = ~7,212 BTU/Hr
Typical System AlphaServer DS10 600 MHz
Power Supply, 300W
Main logic board containing Alpha CPU, EV6, 466 MHz
Main memory = 1 GB
(3) Hard disk drive
(1) Floppy disk drive
(1) CD-ROM disk drive
(1) PCI Graphics Card
(1) PCI Graphics Card
Running system exerciser during the power measurement.
Measured Input Voltage = 116 VAC RMS @ 60Hz
Measured Input Current = 2.27 Amps RMS
Measured Input Power = 176 Watts
Altitude Operating 40,000 ft/12,192 m
(unpressurized) Non-operating 10,000 ft / 3,048 m
Note: Higher altitudes are possible if maximum operating temperature is reduced.
     
Electrical (Power supplies are universal, PFC, auto ranging, 100/240 Vac)
Nominal Voltage (Vac) 100 to 120Vac / 220 Vac
Operating Voltage Range (Vac) (temporary condition) 90 to 128 Vac /180 to 265 Vac
Power Source Phase Single/Single/Single
Nominal Frequency (Hz) 60 Hz /50 Hz
Frequency Range (Hz) 59 to 61 Hz /49-51 Hz
Maximum Inrush Current 11 amps/22 amps
Power Supply (single cordset) 12 amps/5 amps
     
Acoustics (Declared values per ISO 9296 and ISO 7779)
Acoustics

LWadB

LpAm, dBA

LpAm, dBA

   AlphaServer DS10 with one HDD

(Operator position)

(Bystander Position)

Idle

5.7

48

41

Operating

6.0

52

45

Regulatory Agency Approvals UL: Listed to UL1950 (3rd edition)
CUL Listed: CAN/CSA-C22.2 No. 950-M95
TUV: EN 60950/A11: 1997 GS marked
FCC: Part 15 Class B (600-MHz Systems)
Class A (466-MHz Systems)
CE: EN55022, EN50082
VCCI Class II ITE
BMSI: CISPR22, CNS13438
C-Tick: CISPR22, AS/NZS 3548
Reviewed to AS/NZ 3260:1993 Australian/New Zealand Standard
EN 60950/A11: 1997 European Norm
IEC950 (2nd edition, 4th amend)

   DA-10398 28 - Version 28 - October 3, 2001 --- Retired on October 22, 2001