Overview
|
Compaq AlphaServer DS20E
|
| At A Glance |
| AlphaServerAlphaStation DS20E Linux-Ready Systems include: |
|
|
|
Standard Features
| Processor | Alpha 21264 667-MHz or 833-MHz processor | ||
|
|
|||
| Cache Memory | 8-MB level 2 dual data rate cache per processor | ||
|
|
|||
| Upgradability | System upgradable to dual processing | |
|
|
||
| Memory | Minimum | 512-MB or 1-GB ECC 83-MHz SDRAM memory | |
| Maximum | 4 GB | ||
|
|
|||
| Network Controller | Choice of Ethernet controllers |
|
|
|
| Expansion | I/O (Total) | 6 | |
| PCI | 5 | ||
| Shared PCI/ISA | 1 | ||
|
|
|||
| Storage Controller | Choice of storage controllers |
|
|
|
| Storage | Diskette Drive | 1.44 MB | |
| CD-ROM | 24X Max IDE CD-ROM Drive | ||
| Internal Hard Drives | Choice of 18.2-GB, 36.4-GB, 72.8-GB drives | ||
| Maximum Internal Storage | 436 GB | ||
|
|
|||
|
Expansion Ports
|
Parallel | 1 | |
| Serial | 2 | ||
| Pointing Device (Mouse) | 1 | ||
| Keyboard | 1 | ||
| SCSI knockouts on rear of chassis | 6 | ||
|
|
|||
| Form Factor | Rackmount or Pedestal | ||
|
|
|||
| Power Supply | Two 375-Watt hot plug power supplies, standard; optional third N+1 for redundancy |
| Hot plug redundant power supply support; hot plug fan support | |
|
|
|
| Service and Support | HP Services provides a wide range of service offerings including a three-year limited warranty fully supported by a worldwide network of resellers and service providers; lifetime toll-free 7 x 24 hardware technical phone support. |
|
|
Systems
| Step 1 Select system |
|
|
| AlphaServer/AlphaStation DS20E systems require the mandatory selection of the following items: |
|
| NOTE: Graphics adapter, keyboard, mouse, and monitor are recommended. |
|
AlphaServer DS20E Linux-Ready Systems |
||
|
CPU |
Memory/Cache |
Order Number
|
|
667 MHz
|
512 MB/8 MB
|
DJ-56PAB-EA
|
|
667 MHz
|
1 GB/8 MB
|
DJ-56PAB-FA
|
|
833 MHz
|
512 MB/8 MB
|
DJ-56RAA-EA
|
|
833 MHz
|
1 GB/8 MB
|
DJ-56RAA-FA
|
|
AlphaStation DS20E Linux-Ready Systems
|
||
| CPU | Memory/Cache | Order Number |
|
667 MHz
|
512 MB/8 MB
|
DJ-56PAB-EW
|
|
667 MHz
|
1 GB/8 MB
|
DJ-56PAB-FW
|
|
833 MHz
|
512 MB/8 MB
|
DJ-56RAA-EW
|
|
833 MHz
|
1 GB/8 MB
|
DJ-56RAA-FW
|
| Step 2 Select Mandatory Options | |
|
|
Step 2a - Bezel Kits - Mandatory |
||
|
|
||
|
||
| Pedestal/Tower bezel kit | 3X-BA56P-PB | |
| Rackmount bezel kit (M-Series Cabinets) | 3X-BA56R-RC | |
| Rackmount bezel kit for 9000 Series Cabinets
(Onsite integration only contact CustomSystems if factory integration is required) |
3X-BA56R-RE | |
Step 2b - Bezel Kits - Mandatory |
||
|
|
||
|
||
| 6-bay disk drive cage | BA610-6D | |
Step 2c - SCSI Adapter - Mandatory |
||
|
|
||
|
||
| Single-channel LVD adapter, maximum two per system | 3X-KZPCA-AA | |
Step 2d - System Disk Drive (Supported in Disk Drive Cage) - Mandatory |
||
|
|
||
|
||
| 18.2-GB Ultra3 SCSI 10,000 rpm 1-inch Universal disk drive | 3R-A0585-AA | |
| 18.2-GB Ultra3 SCSI 15,000 rpm 1-inch Universal disk drive | 3R-A1543-AA | |
| 36.4-GB Ultra3 SCSI 10,000 rpm 1-inch Universal disk drive | 3R-A0919-AA | |
| 36.4-GB Ultra3 SCSI 15,000 rpm 1-inch Universal disk drive | 3R-A3079-AA | |
| 72.8-GB Ultra3 (LVD) 10,000 rpm 1-inch Universal disk drive | 3R-A3050-AA | |
| Ultra Universal drive height converter (4-pack); required for installed base customers with 4-slot drive cage when ordering 1.0-inch universal drives | 3R-A0528-AA | |
Step 2e - Ethernet Adapters - Mandatory |
||
|
|
||
|
||
| PCI 10/100 Mbit Fast Ethernet adapter, UTP (up to four per system) | 3X-DE600-AA | |
| Cable for 10BaseT twisted pair connection | BN25G-xx | |
Step 2f - Power Cords - Mandatory |
||
|
|
||
|
||
| Pedestal Power Cords | North America, 120V, 75-inch |
BN26J-1K
|
|
| North America, 200 to 240V, 75-inch |
BN18J-1K
|
||
| Australia, New Zealand, 2.5-meter (103541-511) |
BN19H-2E
|
||
| Central Europe, 2.5-meter |
BN19C-2E
|
||
| Denmark, 2.5-meter (103541-481) |
BN19K-2E
|
||
| Egypt, India, South Africa, 2.5-meter (103541-AR1) |
BN19S-2E
|
||
| Israel, 2.5-meter |
BN18L-2E
|
||
| Italy, 2.5-meter (103541-461) |
BN35M-02
|
||
| Japan, 2.5-meter |
3X-BN46F-02
|
||
| Switzerland, 2.5-meter (103541-511) |
BN19E-2E
|
||
| UK, Ireland, 2.5-meter |
BN19A-2E
|
||
|
|
|||
| Rackmount Power Cords | U.S./Canada |
BN20Z-4E
|
| Non-U.S. |
BN35S-4E
|
|
| Japan, 2.5-meter |
3X-BN46D-4E
|
|
|
Options
| Step 3 - Additional CPU Modules - Optional | ||
|
|
||
|
||
| SMP upgrade includes one 6/667-CPU with 8-MB cache, Linux | KN311-CD | |
| SMP upgrade includes one 6/833-CPU with 8-MB cache, Linux | KN312-BD | |
|
|
||
Step 4 - Memory - Optional |
||
|
|
||
|
||
| 512-MB memory option (4 x 128-MB DIMMs) | MS340-DA | |
| 1-GB memory option (4 x 256-MB DIMMs) | MS340-EA | |
|
|
||
Step 5 - Additional Power Supplies - Optional |
||
|
|
||
|
||
| DS20E redundant power supply | FR-H7910-AA | |
|
|
||
Step 6 - External Storage - Optional |
||
|
|
||
| StorageWorks Model 4314R and Model 4354R Universal Drive Shelves |
|
|
| StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf for North America and International use, except Japan (190209-001) | DS-SL13R-AA | |
| StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, Japan (190209-291) | DS-SL13R-AJ | |
| StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf for North America and International use, except Japan (190211-001) | DS-SL13R-BA | |
| StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, Japan (190211-291) | DS-SL13R-BJ | |
|
|
||
| StorageWorks
Model 4314T Standalone Enclosure for Universal Drives |
Model 4314T Ultra3 SCSI, single-bus tower enclosure, U.S. (190210-001) | DS-SL13T-AA |
| Model 4314T Ultra3 SCSI, single-bus tower enclosure, International (190210-B31) | DS-SL13T-AB | |
| Model 4314T Ultra3 SCSI, single-bus tower enclosure, Japan (190210-291) | DS-SL13T-AJ | |
|
|
||
| Storage Controllers
for External StorageWorks Shelves |
NOTE: The following controllers are only supported with StorageWorks shelves (not supported with the 3X-BA611-4D or BA610-6D disk drive cages). | |
| PCI 2-port UltraSCSI single-ended adapter and 10/100 Mbit Ethernet combo adapter (uses 1 PCI slot); includes internal 68-pin and 50-pin HD connectors and two external 68-pin VHDCI SCSI connectors, maximum one per system | KZPCM-DA | |
| VHDCI male-to-VHDCI male UltraSCSI cable; required for each external UltraSCSI shelf attached to KZPCM, xx = 02, 2E [2.5], 02, 05, 10, 20 meters | BN37A-xx | |
| PCI 1-port UltraSCSI single-ended adapter (uses one PCI slot); includes internal 68-pin and 50-pin HD connectors and external 68-pin HD connector, maximum one per system; requires BN38C cable (2 to 20 meters) to connect to single-ended UltraSCSI shelf | KZPBA-CA | |
| PCI 1-port UltraSCSI differential adapter (uses one PCI slot); includes external 68-pin HD connector, maximum four per system; requires BN38C cable (2 to 25 meters) to connect to differential UltraSCSI shelf or external RAID array controller | 3X-KZPBA-CC | |
| 68-pin HD male-to-VHDCI male UltraSCSI cable; required for each external UltraSCSI shelf attached to KZPBA-CA/CB adapter xx = 02, 03, 05, 10, 20, 25 meters | BN38C-xx | |
|
|
||
Step 7 - Storage Devices - Optional |
||
|
|
| AIT Tape Drives | AIT 35/70-GB hot-plug LVD Universal tape drive, uses two slots in BA610-6D or 43xxx shelves, requires 3X-KZPCA-AA adapter |
3R-A2396-AA
|
|
| AIT 50/100-GB hot-plug LVD Universal tape drive, uses two slots in BA610-6D or 43xxx shelves, requires 3X-KZPCA-AA adapter |
3R-A2779-AA
|
||
|
|
|||
| DAT Tape Drive | 20/40-GB DDS4 hot-plug LVD Universal tape drive, uses two slots in BA610-6D, requires 3X-KZPCA-AA adapter |
3R-A2780-AA
|
|
|
|
|||
| SDLT Tape Drives | SDLT tabletop 110/220-GB external tape drive, carbon black - requires 3X-KZPCA-AA LVD adapter - U.S. |
192103-002
|
|
| Same as above International |
192103-B32
|
||
| Same as above Japan |
192103-292
|
||
| SDLT tabletop 160/320-GB external tape drive, carbon black - requires 3X-KZPCA-AA LVD adapter - U.S. |
257319-001
|
||
| Same as above - International |
257319-291
|
||
| Same as above - Japan |
257319-B31
|
||
|
|
|||
| AIT Autoloaders | AIT 35-GB rackmount autoloader, 8 cartridge, U.S. |
280349-001
|
|
| Same as above, International |
280349-B31
|
||
| AIT 35-GB tabletop autoloader, 8 cartridge, U.S. |
292355-001
|
||
| Same as above, International |
292355-B31
|
||
|
|
|||
| Step 8 - Graphics Adapters - Recommended |
||
| 3Dlabs Oxygen VX1 32-MB PCI 2D graphics accelerator (one per system) |
SN-PBXGF-AB
|
|
|
|
||
Step 9 - Monitors - Recommended |
|
|
|
|
|
|
|
|
|
|
Carbon/Silver Monitors |
V7550 17-inch (16inch viewable image size) flat-faced shadow mask color monitor, two-tone (carbon/silver), 0.25mm dot pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO99/Energy Star compliant, Northern Hemisphere with NA power cord, VGA cable |
3R-A4002-AA
|
| Same as above, with Euro power cord |
3R-A4201-AA
|
|
| Same as above, APD, no power cord |
3R-A4202-AA
|
|
| Same as above, with PRC power cord, CCIB |
3R-A4446-AA
|
|
| Same as above, Southern Hemisphere, with Australia/New Zealand power cord |
3R-A4203-AA
|
|
| P930 19-inch (18-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24-mm aperture grille pitch, VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable |
3R-A4215-AA
|
|
| Same as above, with Euro power cord |
3R-A4391-AA
|
|
| Same as above, Taiwan, with NA power cord |
3R-A4392-AA
|
|
| Same as above, with PRC power cord, CCIB |
3R-A4394-AA
|
|
| Same as above, Southern Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord |
3R-A4393-AA
|
|
| P1130 21-inch (19.8-inch viewable image size) FD Trinitron auto-scanning color monitor, 0.24-mm aperture grille pitch, VGA to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable |
3R-A4216-AA
|
|
| Same as above, with Euro power cord |
3R-A4396-AA
|
|
| Same as above, Taiwan, no power cord |
3R-A4397-AA
|
|
| Same as above, with PRC power cord, CCIB |
3R-A4400-AA
|
|
| Same as above, Southern Hemisphere, with Australia/New Zealand power cord |
3R-A4398-AA
|
|
|
|
||
| Carbon/Silver Flat Panel Monitors | TFT1825, 18-inch (18-inchviewable image size) TFT flat panel monitor, 0.28mm pixel pitch, 1600 x 1200 @60Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, one VGA, one DVI-I input connector. NA power cord, VGA and DVI-I cables |
3R-A4292-AA
|
| TFT1520, 15-inch (15-inch viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @75 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA and one DVI-I), NA power cord, VGA and DVI-I cables |
3R-A4249-AA
|
|
|
|
||
| Video Extension Cable | 6-foot/1.8-meter video extension cable |
BN39C-02
|
|
|
||
| Monitor Power Cords | North America, 120V, 75-inch |
BN26J-1K
|
| Australia, New Zealand, 2.5-meter (103541-511) |
BN19H-2E
|
|
| Central Europe, 2.5-meter |
BN19C-2E
|
|
| Denmark, 2.5-meter (103541-481) |
BN19K-2E
|
|
| Egypt, India, South Africa, 2.5-meter (103541-AR1) |
BN19S-2E
|
|
| Israel, 2.5-meter |
BN18L-2E
|
|
| Italy, 2.5-meter (103541-461) |
BN35M-02
|
|
| Japan, 2.5-meter |
3X-BN46F-02
|
|
| Switzerland, 2.5-meter (103541-511) |
BN19E-2E
|
|
| UK, Ireland, 2.5-meter |
BN19A-2E
|
|
|
|
||
Step 10 - Networks and Communications - Optional |
||
|
|
| Ethernet | ||
| PCI (32-bit, 33-MHz) single-port 10/100 Ethernet (UTP/RJ45) NIC, maximum four per system. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
3X-DE600-AA
|
|
| PCI (32-/64-bit, 33-/66-MHz)
single-port 10/100/1000 (UTP/RJ45) Gigabit NIC, copper; no on-board boot-ROM
support, maximum two per system. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
DEGPA-TA
|
|
|
|
||
| FDDI | ||
| PCI (32-bit, 33-MHz)
to FDDI SAS (MMF/duplex-SC) NIC, maximum two per system. Use BN34A, BN34B, or BN34D cables. |
3X-DEFPA-AC
|
|
| PCI (32-bit, 33-MHz)
to FDDI DAS (MMF/duplex-SC) NIC, maximum two per system. Use BN34A, BN34B, or BN34D cables. |
3X-DEFPA-DC
|
|
| MIC-SC dual fiber optic cable |
BN34D-xx
|
|
| SC-to-SC dual fiber optic cable |
BN34B-xx
|
|
| PCI (32-bit, 33-MHz)
to FDDI SAS (UTP/RJ45) NIC, maximum two per system. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
3X-DEFPA-UC
|
|
| PCI (32-bit, 33-MHz) to FDDI DAS
(UTP/RJ45s) NIC, maximum two per system. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
3X-DEFPA-MC
|
|
|
|
||
| Ethernet, FDDI, Multi-use Cables | ||
| Multimode fiber optic (MMF) 62.5/125um
duplex cable, with SC-to-ST connectors. -xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, 30 meters |
BN34A-xx
|
|
| Multimode fiber optic (MMF) 62.5/125um
duplex cable, with SC-to-SC connectors. -xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, 30 meters |
BN34B-xx
|
|
| Category 5e (4-Unshielded Twisted
Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for system
to switch, repeater, or hub connectivity. -xx = available lengths: (0B, 0E, 01, 03, 04, 07) for 0.2, 0.5, 1, 3, 4, 7 meters |
BN25G-xx
|
|
| Category 5e (4-Twisted Pairs,
Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for
system to switch, repeater, or hub connectivity. -xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters |
BN26M-xx
|
|
| Category 5e (4-Unshielded Twisted
Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to switch,
repeater, or hub connectivity. -xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters |
BN24Q-xx
|
|
| Category 5e (4-Twisted Pairs,
Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to
switch, repeater, or hub connectivity. -xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, 7 meters |
BN28Q-xx
|
|
|
|
||
Step 11 - Keyboard and Mouse - Recommended |
||
|
|
||
|
||
|
|
||
|
| Mouse | 3-button mouse carbon | 3R-A3480-AA |
|
|
||
| Keyboard or Mouse Extension Cable | 6-foot/1.8-meter keyboard or mouse extension cable; to extend both keyboard and mouse order two cables | 17-04016-01 |
|
|
||
Step 12 - Console Terminal - Optional |
||
|
|
|
||
| VT510 video terminal; requires H8575-x cable |
VT510-xx
|
|
| Console cable, female connector |
H8575-A
|
|
| Console cable, male connector |
H8575-D
|
|
| Console cable, male connector (IBM compatible) |
H8575-E
|
|
|
|
||
Step 13 - Linux Kit Optional |
||
|
|
| Red Hat Linux CD-ROM Kit |
QA-6M1AA-H8
|
|
|
|
||
Step 14 - Hardware Supplemental Support Services |
||
|
|
|
||
|
|
||
|
Hardware Support - Americas and Asia Pacific only
|
3 Years
|
|
3 Yr 4hr, 13x5 HW support for AlphaSrv/AlphaStation DS20E,4-hour
on-site response,
8am-9pm,M-F excl. HP holidays |
FM-TG4HR-36
|
|
3 Yr 4hr, 24x7 HW support for AlphaSrv/AlphaStation DS20E,4-hour
on-site response.
24x7 incl. HP holidays |
FM-TG724-36
|
|
|
||
| Installation Services | Hardware product installation for DS20E |
FM-TGINS-IN
|
|
|
TechSpecs
|
Pedestal |
Dimensions (H x W x D) |
18.5 x 8.85 x 27.5 in (47 x 22.5 x 69.9 cm) | |
| Shipping Dimensions | 24 x 26.25 x 40 in (61 x 66 x 101.6 cm) | ||
| Weight | |||
| Typical Configuration | 80 lb (36 kg) | ||
| Maximum Configuration | 88 lb (40 kg) | ||
| Shipping Weight | |||
| Nominal | 100 lb (45 kg) | ||
| Maximum | 110 lb (50 kg) | ||
| Clearances | Operating | Service | |
| Front | 15 in (38.1 cm) | 15 in (38.1 cm) | |
| Rear | 6 in (15 cm) | 29.5 in (75 cm) | |
| Left Side | None | None | |
| Right Side | None | None | |
|
|
|||
|
Rackmount |
Dimensions (H x W x D) |
8.75 x 17.5 x 26 in (22.2 x 44.5 x 66 cm) (5U) | |
| Shipping Dimensions | 24 x 26.25 x 40 in (61 x 66 x 101.6 cm) | ||
| Weight | |||
| When lifting: | |||
| Nominal | 80 lb (36 kg) | ||
| Maximum | 86 lb (39 kg) | ||
| Total added to cabinet (brackets, slides, cables): | |||
| Nominal | 84 lb (38 kg) | ||
| Maximum | 88 lb (40 kg) | ||
| Shipping Weight | |||
| Nominal | 100 lb (45 kg) | ||
| Maximum | 110 lb (50 kg) | ||
| Clearances | |||
| Operating | See specific cabinet requirements | ||
| Service | Minimum 4 ft/121.9 cm, 28 in/71 cm withdrawal on rails | ||
|
|
|||
|
Cabinet |
H9A10 M-Series | H9A15 M-Series | |
| Dimensions (H x W x D) (Depth includes rear door extender) |
67 x 23.6 x 41.5 in (170 x 60 x 105.4 cm) |
79 x 23.6 x 41.5 in (200 x 60 x 105.4 cm) |
|
| Shipping Dimensions | 73 x 36 x 48 in (185.5 x 91.5 x 122 cm) |
85 x 36 x 48 in (216 x 91.5 x 122 cm) |
|
| Weight | Configuration dependent | Configuration dependent | |
| Shipping Weight | Nominal: 946 lb (430 kg) | Nominal: 1,056 lb (550 kg) | |
| Maximum: 1,375 lb (625 kg) | Maximum: 1,408 lb (640 kg) | ||
|
|
|||
|
System Unit |
Environmental Temperature |
Operating (Tower, Rackmount) | 50° to 95° F (10° to 35° C) | ||
| NOTE: Maximum operating temperature at sea level; reduce by 1.8° F (1° C) for each 600m (2,000 ft) above sea level. | |||||
| Non-operating | Not tested | ||||
| Storage (60 days) | 40° to 151° F (40 to 66° C) | ||||
| Rate of change | 20° F/hr (11° C/hr) | ||||
| Humidity | Operating | 20% to 80% | |||
| Non-operating | 20% to 80% | ||||
| Storage (60 days) | 10% to 95% | ||||
| Rate of change | 20% hr | ||||
| Maximum Wet Bulb Temperature | Operating | 82° F (28° C) | |||
| Storage (60 days) | 115° F(46° C) | ||||
| Maximum Dew Point Temperature | Operating | 36° F (2° C) | |||
| Heat Dissipation | Nominal | Maximum | |||
| Pedestal | 550W, 1,878 BTU/hr | 780W, 2,664 BTU/hr | |||
| H9A10/H9A15 Cabinets | Configuration dependent | Configuration dependent | |||
| Air Flow and Quality | |||||
| Intake location | Front | ||||
| Exhaust location | Rear Tower, Pedestal, Rack; Rear/top H9A10/H9A15 | ||||
| Particle size | N/A | ||||
| Concentration | N/A | ||||
|
Altitude |
|||||
| Operating | 10,000 ft (3,037m) | ||||
| NOTE: Higher altitudes are possible if maximum operating temperature is reduced (see Temperature); other restrictions may apply such as maximum permissible altitude for hard drives. | |||||
| Non-operating | 40,000 ft (12,192m) | ||||
| Acoustics (Declared values per ISO 9296 and ISO 7779) | |||||
| Acoustics | LWAd3B | LnAm5dBA (bystander position) |
|||
| Idle | 5.8 | 44 | |||
| Operating | 6.3 | 49 | |||
| NOTE: Current values for specific configurations are available from HP, note that 1 B = 10 dBA. | |||||
| Vibration | |||||
| Operating | 10 to 500 Hz .1 G peak | ||||
| Non-operating | 1.03 Grms 5-300 Hz | ||||
| Electrical (Power supplies are universal, PFC, auto ranging, 100/240 VAC) | |||||
| Nominal Voltage (VAC) | 100 | 120 | 200 to 240 | ||
| Voltage Range (VAC) (temporary condition) | 90 to 100 | 110 to 128 | 180-250 | ||
| Power Source Phase | Single | Single | Single | ||
| Nominal Frequency (Hz) | 50/60 | 50/60 | 50/60 | ||
| Frequency Range (Hz) | 49 to 51/59 to 61 | 49 to 51/59 to 61 | 49 to 51/59 to 61 | ||
| RMS Current (maximum steady state) | |||||
| Pedestal and Rackmount | |||||
| Single power cord | 7.5A | 6.0A | 3.8A | ||
| Maximum VA | 780 | 765 | 730 | ||
| M-Series Cabinet (Configuration dependent) | |||||
| Nominal voltage (VAC) | 100 | 120 | 220-240 | ||
| Each power cord | 24A | 24A | 16A | ||
| Power Cords | |||||
| Pedestal | 1 (75 in (190 cm)) | IEC 320 C13 to NEMA
5-15 (North America) or IEC 320 C13 to country-specific |
|||
| Rackmount | 1 (14 ft 10 in (452 cm)) | IEC 320 C13 to NEMA
5-15 (North America) or IEC 320 C13 to IEC 320 C14 (other countries) |
|||
| Cabinet | 2 (10 ft 10 in (330 cm)) | 120V non-removable
NEMA L5-30P or 200-240V non-removable IEC 309 |
|||
| Regulatory | Agency Approvals | UL: Listed to UL1950 (3rd edition) | |||
| CSA: Certified to CAN/CSA-C22.2 No. 950-M95 | |||||
| TUV: EN 60950/A4: 1997 VDE 0805 GS marked | |||||
| FCC: Part 15.B Class A (EV6 500 MHz) | |||||
| FCC: Part 15.B Class B (EV67 667 MHz) | |||||
| CE: EN55022, EN50082 | |||||
| VCCI Class II ITE | |||||
| BCIQ: CISPR22, CNS13438 | |||||
| C-Tick: CISPR22, AS/NZS 3548 | |||||
| Reviewed to | AS/NZ 3260:1993 Australian/New Zealand Standard | ||||
| EN 60950/A4: 1997 European Norm | |||||
| IEC 950 (2nd edition, 4th amend) | |||||
|
|
|||||
| © Copyright 2003 Hewlett-Packard
Development Company, L.P. The information contained herein is subject to change without notice. UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained. |