Overview
|
StorageWorks Enclosure Model 2200 by Compaq
| ||
![]() |
![]() | |
CXO6321D | CXO6322B | |
| | ||
| Introduction |
| The StorageWorks
Enclosure Model 2200 is the new packaging for the HSG80 RAID controller. The Model
2200 provides the connection between the HSG80 and disks installed in StorageWorks
Model 4200 drive enclosures. The Model 2200 supports one or two HSG80s. Two cooperating controllers provide redundancy for high availability. Six UltraSCSI channel connections on the Model 2200 allow for connection for six single bus drive shelves or 3 dual bus drive shelves. |
|
| Models | |
| StorageWorks Enclosure Model 2200 by Compaq | 135820-B21 |
|
|
Product Highlights
| StorageWorks Enclosure Model 2200 | The
StorageWorks Enclosure Model 2200 is the new packaging for the HSG80 RAID controller.
The Model 2200 provides the connection between the HSG80 and disks installed in
StorageWorks Model 4200 drive enclosures. The Model 2200 supports one or two HSG80s. Two cooperating controllers provide redundancy for high availability. Six UltraSCSI channel connections on the Model 2200 allow for connection for six single bus drive shelves or 3 dual bus drive shelves. | ||
|
| |||
| Customized Modular Storage Solutions | The modular packaging components are now available for building customized storage solutions. See the White Paper "Putting it All Together: Configuring Modular Solutions" for full details. Note that the components are now only available for "loose piece" orders where the solutions are assembled on site. Pre-configured storage solutions are currently being qualified. Availability of full CTO configurations will also be announced at that time. | ||
|
| |||
| Component Support | The StorageWorks Enclosure
Model 2200 supports modular storage system configurations containing: StorageWorks
Enclosure models 4214R and 4254 drive shelves. HSG80 RAID Controllers connected to NT host systems: Support for additional operating systems will be announced as they are qualified. |
|
| |
| StorageWorks Enclosure Model 4200 family | The Enclosure Model 2200 supports the Enclosure Model 4200 family of drive shelves. See the "StorageWorks Enclosure Model 4200 Family" QuickSpec for detailed information on the 4214R and 4254 drive shelf options. | ||
|
| |||
| HSG80 | The HSG80 is the Fibre to SCSI RAID controller. It supports 2 Fibre ports to the SAN and 6 SCSI channels to the disk drives. |
|
| |
| HSG80 Fibre Channel Switch and Hub Support | Support
for 8 and 16 port Fibre Channel switches allows the full benefits of a storage
area network (SAN), providing exceptional connectivity while increasing the effective
bandwidth of the network. Supported SAN features include zoning for communication
isolation, switch to switch segments up to 10KM, and FC-AL connections into Brocade
QuickLoop port handling. Support for the 7 and 12 port Fibre Channel hubs offers low cost connectivity to a SAN. |
|
| |
| Model 2200 Fault Tolerance | Redundant power supplies, fans, controllers, cache battery backup, hot global spare drives and a multi-level RAID architecture (0, 1, 3/5, 1+0) ensure fault tolerance to provide the highest level of data availability and data integrity. |
| | |
| Manageability | StorageWorks Command Console (SWCC) provides a graphical user interface (GUI) to setup/configure, monitor, and troubleshoot storage subsystems. |
|
|
Ordering Information
| Adapters/Hubs/SAN Switches Supported | FC PCI HBA for NT, Tru64, OVMS | 380574-001 | |
| Fibre Channel SAN Switch, 16 port | 158223-B21 | ||
| Fibre Channel SAN Switch, 8 port | 158222-B21 | ||
| Fibre Channel Hub 12 | 295573-B22 | ||
| Fibre Channel Hub 7 | 234453-001 | |
| Cabinets Supported | 41U Cab (Blue) 1PDU (Blue 60Hz) | 125359-B21 | |
| 42U Cab (opal) No PDU | 120663-B21, B22,B23 | ||
| 36U Cab (opal) No PDU | 120664-B21, B22,B23 | ||
| 22U Cab (opal) No PDU | 120665-B21, B22,B23 | |
Step
1 Modular Solutions Base Configuration | |||
| The Model 2200 supports a single controller or a dual controller configuration for high availability. | |||
| Model Number | Model Description | Part
Number | |
| 2200 | RAID Controller Shelf 4U | 135820-B21 | |
Step
2 Mandatory Options | |||
| Select each mandatory option with quantities specified. | |||
| Description with parts shipped | Quantity | Part
Number | |
| HSG80 Storage Controller with 256-MB cache | 2 | 176622-B21 | |
| ACS V8.5F Controller FC-AL/FC-SW software | 2 | 128697-B21 | |
| Windows® NT®/Windows 2000 OS Platform Kit | 1
per O/S | 380551-001 | |
| Single external cache battery | 2 | 135823-B21 | |
Step
3 Related Options | |||
| Description with parts shipped | Quantity | Part
Number | |
| 256MB additional cache for HSG80 | 2 | 380674-B21 | |
| HSG80 cache bulkhead upgrade | 2
(see NOTE) | 176623-B21 | |
| NOTE: The cache bulkhead upgrade is only required for existing HSG80 controllers that are being moved from a BA370 enclosure into the Model 2200. New HSG80 controllers ordered under 176622-B21 ship with the appropriate cache. |
| ||
| Disk Enclosures |
For maximum
capacity order the Single Bus shelf. For maximum performance order the Dual Bus
shelf. 42xx drive shelves do not allow daisy-chaining between shelves. | ||
| Disk Enclosure Model 4214R 3U,RETMA mounting kit, Single Bus, single power supply 14-bay drive shelf | 6
maximum per controller shelf | 103381-001 | |
| 4214R Redundant power supply | 1
per 4214R (optional) | 119826-B21 | |
| 4214R Dual Bus I/O module | 1
per 4214R (optional) | 119829-B21 | |
| Disk Enclosure Model 4254 3U, RETMA mounting kit, Dual Bus, Dual power supplies, 14-bay drive shelf | 3
maximum per controller shelf | 138151-001 | |
| Disk Drives | 18.2 GB Ultra2,10,000 rpm,
1 in (2.54 cm) Drive | 12
maximum per disk shelf | 128418-B22 |
| 9.1 GB Ultra2, 10,000 rpm, 1 in (2.54 cm) Drive | 12
maximum per disk shelf | 328939-B22 | |
| 18.2 GB Ultra2, 7200 rpm, 1 in (2.54 cm) Drive | 12
maximum per disk shelf | 388144-B22 | |
| 9.1 GB Ultra2, 7200 rpm, 1 in (2.54 cm) Drive | 12
maximum per disk shelf | 123065-B22 | |
| SCSI Cables | The
total number of cables ordered should equal the total number of device shelf I/O
Module ports. Always try to order the shortest cables possible to avoid excessive cable storage within the rack. | ||
| 3M VHDCI to VHDCI SCSI Cable | BN37A-03 | ||
| 5M VHDCI to VHDCI SCSI Cable | BN37A-05 | ||
| 10M VHDCI to VHDCI SCSI Cable | BN37A-10 | ||
| 2.5M VHDCI to VHDCI SCSI Cable | BN37A-2E | ||
| 1.5M VHDCI to VHDCI SCSI Cable | BN37A-1E | | |
| Power Cords 13-20 Amp |
The 4214R and
4254 country kits ship with the appropriate power cords. The Model 2200 ships
with two power cords that connect directly into a Power Distribution Unit (PDU).
For connection to a wall outlet or a power strip, different power cords are required. | ||
| U.S. | 103541-001 | | |
Optional
services and support available | |
| Software Product Services | Software
Product Services (recommended for all installations)
| |
| Hardware Product Services |
|
|
|
Technical Specifications
| Model | StorageWorks Enclosure Model 2200 by Compaq | |||
| Controller Model | HSG80 | |||
| Controller Cache | 256 MB per controller standard, 512 MB optional | |||
| Battery Backup for Cache | Yes | |||
| Array Controller Software (ACS) | FC-AL, FC Switch support ACS V8.5F | |||
| Host Interface | Arbitrated Loop (FC-AL) or Fibre Channel Switched Fabric | |||
| Host Ports per Controller | 2, Multi-bus with Transparent Failover | |||
| Drive Interface | SE Ultra-wide SCSI, 6 channels | |||
| RAID Levels | 0, 1, 0+1, 3/5 and Partitioning | |||
| Max. Disks Supported | 72 per Controller Pair | |||
| Non-RAID JBOD Support | Yes | |||
| Fibre Channel Switches | 16 Port Optical, 8 Port Optical | |||
| Fibre Channel Hubs | 7 Port Optical, 12 Port Optical | |||
| Disks | Compaq Universal Drives | |||
| HSG80 O/S Support | Windows NT, NetWare, Tru64 UNIX®, OpenVMS, Sun Solaris, SGI IRIX, HP-UX, IBM AIX | |||
| HSG80 Sustained I/O Rate | Over 24K IOPS per Controller Pair | |||
| Redundant Fans | YES. N+1 | |||
| Environmental Monitoring Unit | Yes. Monitors Power and Temperature | |||
| Regulatory approvals | UL, CSA, TUV, FCC, CE MARK, CTICK | |||
| Management Software | StorageWorks Command Console (SWCC) | |||
|
| ||||
Physical
Specifications | |||||
| Physical dimensions | Unpacked/no controllers installed | Shipping | |||
| Height | 5.9 in (14.99 cm) | 30.4 in (77.2 cm) | |||
| Width | 17.5 in (44.45 cm) | 13.6 in (34.5 cm) | |||
| Depth | 22 in (55.88 cm) | 29.0 in (50.8 cm) | |||
| Weight (maximum) | 26.6 lb (58.8 kg) | 65 lb (29.5 kg) | |||
| Required Front Clearance | 2.0 in (5.08 cm) | ||||
| Required Rear Clearance | 4.0 in (10.16 cm) | ||||
| Power requirements | 100V - 240V ± 1-% | ||||
| AC plug type | 3 Wire IEC 320 (20A) | ||||
| Number of phases | Single | ||||
| Rated current | 2.5A @ 110V - 120V AC, 60Hz | ||||
| 1.2A @ 220V - 240V AC, 50 Hz | |||||
| BTU rating | 410 BTU per hour | ||||
| Nominal airflow | 30 cubic ft/minute | ||||
| Wattage | 120 Watts maximum (input) | ||||
| Operating environment | Temperature | 50° to 95°F/10° to 35°C - with an average rate of change of 3°C/h maximum and a step change of 3°C/h or less | |||
| Humidity | 40% to 60% (non-condensing) with a step change of 10% or less (non-condensing) | ||||
| Altitude | |||||
| Air Quality | Not to exceed 500,000 particles per cubic foot of air at a size of 0.5 micron or larger per cubic foot of air | ||||
| Regulatory approvals | UL, CSA, TUV, FCC, CE MARK, C TICK | ||||
| | |||||
| ©
Copyright 2003 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Windows NT is a US registered trademark of Microsoft Corporation. Unix is a registered trademark of The Open Group. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |