Overview
|
HP StorageWorks 4300 Enclosure |
| Description |
| The HP StorageWorks Enclosure 4300 is an Ultra3 SCSI disk drive storage enclosure. These enclosures deliver industry-leading data performance, availability, storage density, and upgradability to meet customers' demanding and growing storage needs. The drive carrier is designed to support the fastest current and next generation Ultra3 and Ultra2 hard drives on the same SCSI bus. The ease of upgrading the StorageWorks Enclosure 4200 to the StorageWorks Enclosure 4300 proves to our customers that HP provides the lowest cost of ownership, as well as the fact that technology transitions can be smooth without disrupting critical business environments. |
|
|
|
Models |
Model 4314R |
Rack-mountable 14 drive enclosure
with single bus, single power supply |
190209-001
|
| Model 4314T |
Tower 14-bay drive enclosure, single bus, single power supply, LCD monitor |
190210-001
|
|
| Model 4354R | Rack-mountable 14 drive enclosure with dual bus, dual power supplies |
190211-001
|
|
|
|
|||
|
Customer Benefits |
Higher Performance |
Ultra3 SCSI transfer rates combined with the highest spindle count per U of rack space allows the StorageWorks Enclosure 4300 to achieve the greatest I/Os per second. |
| Storage Capacity | 3U rack form factor allows customer to achieve the maximum storage capacity per square foot in the data center. | |
| Upgradability | Ultra3 single and dual I/O upgrade modules make upgrading the StorageWorks Enclosure 4200 to Ultra3 quick and easy. | |
| Investment Protection | With the ability to upgrade, as well as mix and match, existing Ultra2 components with Ultra3, HP makes technology transitions simple and cost effective, and has simplified the transition to the next generation SCSI protocol. | |
| Reduced spares inventory | Universal drives and drive carriers across HP's entire Ultra2, Ultra3, and Ultra320 product offering allow the same drives to be used in servers and external storage. | |
|
|
||
|
Product Family Models: |
The hp StorageWorks 4300 Enclosure design allows for specific configurations tailored to the needs of all HP server customers. Three models are available today: | |
|
Rack-mountable 14 drive enclosure with single bus, single power supply | |
|
Tower mount 14 drive enclosure with single bus, single power supply, LCD monitor | |
|
Rack-mountable 14 drive enclosure
with dual bus, dual power supplies |
|
| All models are universal drive enclosures and are supported behind HP Smart Array controllers, HSGx0 controllers, and adapters. | ||
| NOTE: For complete compatibility information, refer to the Specifications section of this document. | ||
|
|
||
| Feature List | Ultra3 (LVD) data transfer rates (160 MB/s) 3U rack height Hot pluggable disk drives, power supplies, and fan pack Redundant fans Redundant power supplies (optional on the 4314R) Single or dual bus I/O |
||
|
|
|||
| Key Features | |
|
NOTE: All models of the StorageWorks Enclosure 4300 Family have the following features: |
|
|
|
Product Highlights
| Upgradability |
Upgrading a StorageWorks Enclosure 4200 to a StorageWorks Enclosure 4300 is as easy as swapping out the I/O module on the back of the unit. The I/O module is warm-swappable, therefore during the upgrade power to the unit can remain on, but all I/O operations need to be stopped to ensure that no data is lost during the upgrade. |
|
|
|
| Mix and Match |
All Ultra320, Ultra3, and Ultra2 devices from HP are compatible with one another so customers can mix and match components in the same storage enclosure or server. When Ultra2, Ultra3, and Ultra320 devices are found on the same Ultra3 SCSI bus, each device will transfer data at its individual interface transfer rate up to the transfer rate of the SCSI bus.. |
| NOTE: For customers who operate legacy Models 4310R and 4350R enclosures, the use of 1-inch Universal Ultra2, Utlra3, or Ultra320 disk drives requires the addition of 0.6-inch drive extenders. | |
|
|
|
| Hot Pluggable |
Hot pluggable technology is designed into drives, power supplies and redundant cooling fans. Hot pluggable components can be replaced without powering down the storage system or stopping I/O operations. This feature significantly enhances data availability. |
|
|
|
| Auto SCSI ID Selection |
SCSI ID is automatically set when a drive is inserted into a drive bay. |
|
|
|
| LED Indicators |
Front panel LEDs indicate drive activity, required drive service, and power, giving a quick visual assessment of overall system storage status. LED status and fault indicators for the fans and power supplies are located in the back of the enclosure. |
|
|
|
| Rack Density |
The StorageWorks Enclosure 4300 models have a 3U height. |
|
|
|
| Environment Monitoring Unit (EMU) |
Each StorageWorks Enclosure 4300 model is equipped with an EMU that constantly monitors the enclosure, the power supplies, and fans to ensure suggested operating tolerances are maintained. |
|
|
|
| Single Bus I/O Module |
The single bus I/O module allows one SCSI channel to access all drives in the StorageWorks Enclosure 4300. |
|
|
|
| Dual Bus I/O Module |
The dual bus I/O module allows two SCSI channels to access a single StorageWorks Enclosure 4300. This allows for greater fault tolerance (controller duplexing) or provides access from two different servers to two separate storage areas. |
|
|
|
| Fault Tolerance |
With the dual bus I/O module, redundant power supplies and fans, the StorageWorks Enclosure 4300 family provides a high level of system availability. Using an internal or external RAID Array, the StorageWorks Enclosure 4300 family can be configured for RAID levels 0, 1, 0 1, 5. |
|
|
|
| Manageability |
Depending on the host controller, the StorageWorks 4300 Enclosure is managed by HP Insight Manager or StorageWorks Command Console. |
|
|
|
| Compatibility and Integration Testing |
Intensive compatibility and performance testing with HP ProLiant severs and AlphaServers ensures the highest level of integration available in the industry on a HP server. For a complete list of supported HP servers and workstations, please refer to the QuickSpecs and/or User Guide of the array controller or Host Bus adapter that you are planning to use. The list of supported array controllers and SCSI adapters is provided under "Related Options, Controllers |
|
|
|
| Product Kit Contents |
Model 4314T |
Single power supply, single bus I/O module, 14 drive blanks, warranty card, AC power cord, Enclosure 4300 tower user guide, EMU booklet, HP SmartStart CD Kit, documentation CD, and one 12-ft VHDCI to VHDCI SCSI cable: |
| Model 4314R | Single power supply, single bus
I/O module, 14 drive blanks, warranty card, mounting hardware, Enclosure
4300 user guide, EMU booklet, HP SmartStart CD Kit, documentation CD, and
two 12-ft VHDCI to VHDCI SCSI cables (one 110V and one 220V). |
|
| Model 4354R | Redundant power supplies, dual
bus I/O module, 14 drive blanks, warranty card, mounting hardware, Enclosure
4300 user guide, EMU booklet, HP SmartStart CD Kit, documentation CD, and
two 12-ft VHDCI to VHDCI SCSI cables (one 110V and one 220V). |
|
| NOTE:
A different SCSI cable may be required when the StorageWorks Enclosure
4300 is intended for connection to an HSG80 controller in a Model 2200 controller
enclosure or a host-based adapter on an Alpha server. See the Related Options
section of this document for cable ordering information. NOTE: To maintain proper cooling and airflow, a drive blank or drive must occupy all bays during operation. |
||
|
|
||
| Warranty | StorageWorks Enclosure 4300 family: Three-year limited warranty |
| NOTE: Certain restrictions and exclusions apply. Consult the Customer Support Center at 1-800-345-1518 for details. | |
| Hard drive Pre-Failure Warranty: When used with any one of the StorageWorks Smart Array Family controllers and monitored under HP Insight Manager (v4.20 or later), HP hard drives are supported by a Pre-Failure (replacement) Warranty. | |
| NOTE: Pre-Failure Warranty is available on all HP Prosignia and HP ProLiant servers using HP Insight Manager v4.20 or later, and covers Pentium Pro processors, ECC memory, server hard drives, and external storage enclosure hard drives (except the 535 MB Fast-SCSI-2 hard drive) using HP IDA, IDA-2, HP SMART SCSI Array Controllers, HP SMART-2 Array Controllers or HP Smart Array Controllers. Certain restrictions and exclusions apply. Consult the Customer Support Center at: 1-800-345-1518 for details. |
|
|
Service And Support
| Software Product Services |
Standalone telephone support
Rights to new license version Media and documentation updates |
|
|
|
| Hardware Product Services |
Installation services
On-site maintenance (includes warranty support) Response time upgrades during the warranty period Post-warranty coverage RAID setup and performance consulting via statement of work For additional hardware installation and maintenance information, please refer to the URL listed below: http://www.hp.com/hps/carepack/services/cp_installation.html |
|
|
|
| Warranty Upgrade Options |
Response - Upgrade on-site response from next business
day to same day 4 hours
Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days Duration - Select duration of coverage for a period of 1, 3, or 5 years |
|
|
|
| Hardware Product Services | Sample part numbers: | |
|
3 year, uplift to 5 x 9, Next
Day Response 3 year, uplift to 5 x 9, 4-hour Response 3 year, uplift to 7 x 24, 4-hour Response |
|
| **
Represents a two-digit, product-specific code Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. Care Pack is not available for less than the product's warranty duration. Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required. Care Pack services are prepaid. For additional HP Care Pack Services (hardware & software) information, as well as orderable part numbers, please refer to the URL http://www.hp.com/hps/carepack/ |
||
|
|
||
| Components |
The following brick level options/components do not have
individual HP Care Pack Services. These items will be included in product
Care Pack Services into which they are installed.
|
||||
| Disk Drives |
Tape Drives | CD/DVD ROM | SCSI Hubs in SBBs | Adapters | |
| Bus Converters | Backplane RAID Controllers | Power Supplies | Cabling | Fans | |
|
|
Configuration Information
| Product | Shipping Dimensions |
UPC Code
|
Part Number
|
| StorageWorks Enclosure 4314T |
25.25 x 12.5 x 23.5 in/64.1 x 31.8 x 59.7 cm |
720591469795
|
190210-001
|
| StorageWorks Enclosure 4314T (Int'l) |
720591469801
|
190210-B31
|
|
| StorageWorks Enclosure 4314T (Japan) |
720591469818
|
190210-291
|
|
| StorageWorks Enclosure 4314R | 25.25 x 12.5 x 23.5 in/64.1 x 31.8 x 59.7 cm |
720591469566
|
190209-001
|
| StorageWorks Enclosure 4314R (Int'l) |
720591469583
|
190209-B31
|
|
| StorageWorks Enclosure 4314R (Japan) |
720591469788
|
190209-291
|
|
| StorageWorks Enclosure 4354R | 25.25 x 12.5 x 23.5 in/64.1 x 31.8 x 59.7 cm |
720591469825
|
190211-001
|
| StorageWorks Enclosure 4354R (Int'l) |
720591469832
|
190211-B31
|
|
| StorageWorks Enclosure 4354R (Japan) |
720591469849
|
190211-291
|
|
| Ultra3 Single Bus Upgrade I/O Module | 12.75 x 8 x 3.75 in/32.13 x 20.16 x 9.45 cm |
720591469856
|
190212-B21
|
| Ultra3 Dual Bus Upgrade I/O Module | 13.25 x 8 x 8.5 in/33.39 x 20.16 x 21.42 cm |
720591469863
|
190213-B21
|
| Redundant Power Supply, 499 watts | 3.75 x 8 x 12.75 in/9.52 x 20.32 x 32.38 cm |
808736966726
|
338296-B21
|
| Redundant Power Supply, 499 watts (Int'l) |
808736966740
|
338296-B22
|
|
|
Redundant Power Supply, 499 watts (Japan) |
808736966764
|
338296-B23
|
| Description |
UPC Code
|
Part Number
|
|
| Controllers & Adapters Supported |
HSG80 Controller
|
720591351335
|
176622-B21
|
| NOTE: HSG80 connection to the model 4300 requires the use of the Model 2200 controller shelf: 135820-B21 | |||
| Smart Array 6402 |
273914-B21
|
||
| Smart Array 5302/128 |
283552-B21
|
||
| Smart Array 5304/256 |
283551-B21
|
||
| Smart Array 642 |
291967-B21
|
||
| NOTE: Supported at Ultra2 speeds | |||
| Smart Array 532 |
225338-B21
|
||
| Smart Array 5i/5i Plus |
N/A
|
||
| NOTE: Single external SCSI channel supported on select ProLiant Servers. See Server QuickSpecs for specific model information. | |||
| 64-bit/133MHz dual channel Ultra320
SCSI Adapter |
268351-B21
|
||
| 64-bit Dual Channel Wide Ultra3 SCSI Adapter |
743172876379
|
129803-B21
|
|
| 1 channel Ultra2 (LVD) Adapter (AlphaServer systems) |
743172900562
|
136237-B21/ SN-KZPCA-AA
|
|
| 1 channel Ultra2 (LVD) Adapter (AlphaServer systems) |
613326184219
|
3X-KZPCA-AA
|
|
|
|
|||
| Power Options | Redundant Power Supply, 499 watts |
808736966726
|
338296-B21
|
| Redundant Power Supply, 499 watts (Int'l) |
808736966740
|
338296-B22
|
|
| Redundant Power Supply, 499 watts (Japan) |
808736966764
|
338296-B23
|
|
| StorageWorks Enclosure Ultra3 Single Bus I/O Module |
720591469856
|
190212-B21
|
|
| StorageWorks Enclosure Ultra3 Dual Bus I/O Module |
720591469863
|
190213-B21
|
|
| StorageWorks Enclosure Tower to Rack Conversion Kit |
743172948182
|
150213-B21
|
|
| 39-ft (12m) VHDCI to VHDCI SCSI Cable |
743172948199
|
150214-B21
|
|
| 24-ft (7m) VHDCI to VHDCI SCSI Cable |
720591275983
|
164604-B21
|
|
|
Options
| Rack Options | Wide 41U cabinet (Opal) |
720591823511 | 238789-B21 |
| NOTE: Configuration restrictions apply, please see modular array QuickSpecs for details: http://h18006.www1.hp.com/storage/arraysystems.html42U | |||
| Modular Storage Cabinet 60 Hz (Opal) |
720591398378 |
180311-B21 | |
| 36U Modular Storage Cabinet 60 Hz (Opal) |
720591398606
|
180313-B21
|
|
| 22U Modular Storage Cabinet 60 Hz (Opal) |
720591398651
|
180315-B21
|
|
| 41U Modular Storage Cabinet 60 Hz (Blue) |
720591398880
|
180317-B21
|
|
| 41U Modular Storage Cabinet 50 Hz (Blue) |
720591398897
|
180318-B22
|
|
| NOTE: Each Modular Storage Cabinet (42U, 41U, 36U, and 22U) comes with redundant 220 to 240V PDUs and power cables to accommodate Modular Array configurations. For more details on Modular Array solutions, see http://h18006.www1.hp.com/storage/arraysystems.html | |||
|
|
|||
| Legacy Racks Supported | Rack 7142 | ||
| Rack 9142 | |||
| Rack 9136 | |||
| Rack 9122 | |||
| NOTE: Certain power support and cooling restrictions apply when housing a maximum number of Model 4314R or Model 4354R enclosures in one of the supported HP racks. Please refer to http://h18006.www1.hp.com/storage/index.html for more information or consult the Customer Support Center at 1-800-345-1518 for details. | |||
|
|
|||
| Universal SCSI Drives Ultra 320 Drives |
146.8-GB Pluggable Ultra320 SCSI
10,000 rpm Hard Drive |
286716-B22 |
| 72.8-GB Pluggable Ultra320 SCSI 10,000 rpm Hard Drive | 286714-B22 | |
| 36.4-GB Pluggable Ultra320 SCSI 10,000 rpm Hard Drive | 286713-B22 | |
| 72.8-GB Pluggable Ultra320 SCSI 15,000 rpm Hard Drive | 286778-B22 | |
| 36.4-GB Pluggable Ultra320 SCSI 15,000 rpm Hard Drive | 286776-B22 | |
| 18.2-GB Pluggable Ultra320 SCSI 15,000 rpm Hard Drive | 286775-B22 | |
| 0.6-inch (1.52 cm) Drive Extenders (package of 4) | 148649-B21 | |
| (1)Ultra 2 and Ultra3
drives are also supported in 4300 configurations (2) For pre-existing 10-bay solutions, drive height extenders are attached to 1 in drives for use in 1.6 in drive bay. |
||
| NOTE: Go to the HP SCSI Hard Drive Compatibility table for complete drive compatibility information (http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data. | ||
|
|
||
| SCSI Cable Options | Cables for use with HSG80 controller in the Model 2200 controller enclosure | ||
| 2M SCSI cable for connection to the Model 2200 Controller Shelf |
720591304515
|
168257-B21
|
|
| 3M SCSI Cable for connection to the Model 2200 Controller Shelf |
743172825544
|
188505-B21
|
|
| Cables for use with Smart Array controllers | |||
| 12 ft VHDCI to 68-pin SCSI Cable |
743172660848
|
341177-B21 | |
| 24-ft VHDCI to VHDCI SCSI Cable |
720591275983
|
164604-B21
|
|
| 39-ft VHDCI to VHDCI SCSI Cable |
743172948199
|
150214-B21
|
|
| Cables for use with the KZPCA-AA host bus adapter | |||
| 1M SCSI 68HD Cable |
None
|
BN38C-01
|
|
| 2M SCSI 68HD Cable |
None
|
BN38C-02
|
|
| 5M SCSI 68HD Cable |
None
|
BN38C-05
|
|
|
|
Technical Specifications
| Protocol Support |
Wide Ultra3 (LVD)
Wide Ultra2 (LVD) |
|
| O/S Support |
Defined by specific HP array controller or SCSI adapter
used; please refer to the QuickSpecs and/or User Guide of the specific
array controller or SCSI adapter
|
|
| Dimensions (HxWxD) | Tower Rack |
22.5 x 13.25 x 23 in (56.7 x 33.9
x 57.96 cm) 5.2 x 19 x 20.5 in (13.1 x 47.88 x 51.66 cm) |
| Shipping Dimensions (HxWxD |
Tower
Rack Redundant Power Supply |
34.25 x 14.5 x 31.25 in (86.31
x 36.54 x 78.75 cm) 34.25 x 14.5 x 31.25 in (86.31 x 36.54 x 78.75 cm) 3.75 x 8.0 x 12.75 in (9.52 x 20.32 x 32.38 cm) |
| Weight |
Tower
Rack Redundant Power Supply |
93 lb (42.8 kg) 68 lb (30.9 kg) 6.6 lbs (3.0 kg) |
| LED Indicators (on front panel) |
EMU Status LED (left) Enclosure Power LED (middle) Fault LED (right) |
|
| Drive LED Indicators (on drive trays) | Drive LED (top) On Line LED (middle) Drive Failure LED (bottom) |
|
| Enclosure LED Indicators (back of unit) | I/O Module (top) EMU (middle) Power supplies (bottom) |
|
| Input Requirements |
Nominal Line Voltage
Range Line Voltage Line Frequency Typical Input Current |
110 to 240 V AC 90 to 264 V AC 47 to 63 Hz 2.3A at 120 V AC |
| Relative Humidity (non-condensing) |
Operating
Shipping |
10% to 90% 5% to 90% |
| Enclosure LED Indicators (back of unit) | Smart Array 6402 Smart Array 5302/128 Smart Array 5312 Smart Array 5304/256 Smart Array 642 |
|
| NOTE: Supported at Ultra2 speeds | ||
| Smart Array 532 Smart Array 5i/5i Plus |
||
| NOTE: Single external SCSI channel supported on select ProLiant Servers. See Server QuickSpecs for specific model information. | ||
| HSG80 Controller HSG60 Controller 64-bit Dual Channel Wide Ultra3 SCSI Adapter 1 channel Wide Ultra2 Adapter (AlphaStations) 1 channel Wide Ultra2 Adapter (AlphaServer systems) |
||
| NOTE: See your server and controller compatibility matrix for details on controller and server compatibility. | ||
| Power | 377 Watts per supply (load) | |
| BTU (220 volts) |
Single power supply 14 drives
Single power supply 5 drives Single power supply 1 drive Dual power supply 14 drives Dual power supply 5 drives Dual power supply 1 drive |
1164 BTUs/hour 536 BTUs/hour 273 BTUs/hour 1232 BTUs/hour 625 BTUs/hour 352 BTUs/hour |
| Temperature Range |
Operating
Shipping |
50° to 94° F (10°
to 35° C ) -40° to 151° F (-40° to 66° C) |
| NOTE: To maintain proper cooling and airflow, a drive blank or drive must occupy all bays during operation. | ||
|
|
||
| © Copyright 2003 Hewlett-Packard
Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the
express warranty statements accompanying such products and services. Nothing
herein should be construed as constituting an additional warranty. HP
shall not be liable for technical or editorial errors or omissions contained
herein. |