Overview
|
HP Uninterruptible Power System T1000 XR, T1500 XR and T2200 XR |
| The Tower UPS "XR" models are the next generation
HP UPSs that support optional Extended Runtime Modules and include the T1000
XR, T1500 XR and T2200 XR models. The HP UPS "XR" models denote
"eXtended Runtime Capable" UPS models. Additionally, these UPSs
support superior battery management, load segmentation, and option cards.
The HP tower UPSs are designed to provide maximum protection for workgroup,
departmental, and enterprise server platforms. HP UPSs protect your computer equipment and your critical data against damage due to inconsistent and fluctuating power. They enable you to continue working during sudden brief events of power outage, and automatically save your data, close applications, and stage a systematic shutdown during an extended power outage. Bundled with Power Management Software, the UPSs allow customers to also perform a remote shut down of applications and connected equipment if required. |
|
|
![]() |
||
|
1. LED Display
|
||
|
2. Button Controls
|
||
|
3. Removable front panel
|
| HP Uninterruptible Power System T1000 XR, T1500 XR and T2200 XR Models | HP UPS T1000 XR |
204155-001
|
| HP UPS T1500 XR |
204155-002
|
|
| HP UPS T2200 XR Low Voltage |
204451-001
|
|
| HP UPS T2200 XR High Voltage |
204451-002
|
|
|
|
||
| Related Options | Extended Runtime Module (ERM), T1000 XR |
218967-B21
|
| Extended Runtime Module (ERM), T1500/T2200XR |
218969-B21
|
|
| Six Port Option Card |
192185-B21
|
|
| SNMP/Serial Port Card |
192189-B21
|
|
|
|
||
| Key Features |
NOTE: Certain restrictions and exclusions apply. Consult the HP Computer Support Center for details. |
|
|
Product Highlights
| Easy Configuration via Enhanced Front Panel Display | The new UPS models have an enhanced front panel display. LED display lights and switch membrane is integrated into the front panel that can be configured through a four button control (three buttons for UPS power control and one button under the front bezel for configuration). | |
| | ||
| Increased System Uptime with Extended Runtime Modules | The new HP UPS "XR" models support (optional) extended runtime modules that extend your overall runtime. | |
| | ||
| Investment Protection with Enhanced Battery Management | HP UPSs incorporate Enhanced Battery Management; an exclusive, patented technology that doubles battery service life, optimizes battery recharge time, and provides advance notice of pending battery failure. With Enhanced battery Management, you have a lower overall cost of ownership and receive the best in the industry protection for your critical equipment. |
| | |
| Enhanced System Flexibility with HP Option Cards | HP UPS "XR" models are equipped with a standard serial port via an internal slot. This slot supports two option cards: the Six Port Card and the SNMP/Serial Port Card. These option cards seamlessly integrate into the back of the UPS and provide increased system flexibility. | |
| SNMP/Serial Port Card, PN 192189-B21: Ideal for networked environments, this option card enables network administrators to remotely diagnose, monitor and reboot network devices via SNMP. | ||
| Six Port Card, PN 192185-B21: This option card lets you communicate (via standard DB-9 serial ports) with multiple servers. The maximum number of servers that can be connected using this card depends on the number of load segments available on the UPS. For example, the UPS T2200 XR has 3 load segments, so this card will allow you to serially communicate with up to 3 servers. | ||
|
| ||
| Intelligent Manageability | HP UPSs ship with Power Management Software, which enables you to monitor and control HP UPSs locally or remotely. This software is a versatile, fully configurable, alert response tool that gives system administrators a full overview of the network's conditions. It enables you to monitor system status and power conditions, configure shut down timing, customize alert messages, and perform UPS diagnostic checks quickly and easily. | |
| | ||
| Ease of Maintenance with Hot-Swappable Battery | HP UPSs are designed with hot-swappable batteries. With simple access through the front panel. Users can safely install a new battery without ever powering down connected computer equipment. | |
| | ||
| Independently Controllable Load Segments | All Tower UPS "XR" models incorporate independently controllable load segments (groups of outlets) that allow for prioritized shutdown of multiple servers. Managed through the Power Management software, each individual load segment can be pre-configured by the system administrator to conduct a prioritized shutdown extending the runtime of your most critical servers. In addition, this feature promotes energy and power conservation by facilitating scheduled shutdown and startups during low usage such as weekends and holidays. | |
| | ||
| HP Quality | HP hardware qualification is the toughest in the industry. Extensive evaluation, testing, product improvement, and an unsurpassed warranty guarantee the highest level of system protection, electrical performance, product quality and compatibility. | |
|
| ||
| Warranty | HP UPSs are covered by a three-year
warranty, with the first year including parts and labor. Also, standard
on all HP UPS units is our exclusive Battery Pre-Failure Warranty, which
extends the advantage of a HP three-year, limited warranty by applying it
to the battery before it actually fails. This warranty is offered worldwide.
Specifically, the Pre-Failure Battery Warranty ensures that when customers
receive notification from HP Power Management Software that the battery
may fail, the battery is replaced free of charge under the warranty. NOTE: $25,000 Computer/Load Protection Guarantee is also provided. |
|
|
Service and Support, Care Pack and Warranty Information
| HP Care Pack Installation | ||
| Hardware Installation (Electronic) |
U4690E
|
|
| Care Pack services provide
a range of life cycle support options that let you choose the service levels
that meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
NOTE: For more
information on HP Care Pack services, contact any of our worldwide sales
offices, resellers or visit our worldwide website at: http://www.hp.com/hps/carepack
|
||
|
|
||
| Warranty Upgrade Options |
|
|
| HP Care Pack Information | For
additional HP Care Pack (hardware & software) information, as well as orderable
part numbers, please refer to the URL listed below: http://h18005.www1.hp.com/services/carepaq/index.html | |
|
|
Technical Specifications
| UPS T1000 XR Specifications | ||
| Low-Voltage Models | T1000 XR |
204155-001 |
| Operating Voltage Settings |
120V | |
| Power Out (VA/Watts) |
1000/700 | |
| Input Connection |
5-15P (attached cord) | |
| Output Connection |
(6) 5-15R | |
| Load Segments | 2 | |
| NOTE: Part Number 204155-001 is user selectable for 110V, or 120V via front panel. | ||
| Extended Runtime Module Option | ERM, T1000 XR |
218967-B21 |
| Shipping Dimensions |
14.50 x 22.0 x 25.0 in (36.83 x 55.88 x 63.5 cm) | |
| Shipping Weight | 77 lb (35 kg) | |
| Unit Dimensions (WxHxD) | 6.37 x 9.50 x 16.2 in (16.18 x 24.13 x 41.15 cm) | |
| Shipping Dimensions | 14.50 x 22.0 x 21.0 in (36.83 x 55.88 x 53.34 cm) | |
| Unit Weight | 34.45 lb (15.62 kg) | |
| Shipping Weight | 43 lb (19.5 kg) | |
|
|
||
| UPS T1500 XR Specifications | ||
| Low-Voltage Models | T1500 XR |
204155-002 |
| Operating Voltage Settings |
120V | |
| Power Out (VA/Watts) |
1440/1050 | |
| Input Connection |
Attached 6' power cord with NEMA 5-15P | |
| Output Connection |
(6) 5-15R | |
| Load Segments | 2 | |
| NOTE: Part Number 204155-002 is user selectable for 110V, or 120V via front panel. | ||
| Extended Runtime Module Option | ERM, T1000 XR |
218967-B21 |
| Shipping Dimensions |
14.50 x 22.0 x 25.0 in (36.83 x 55.88 x 63.5 cm) | |
| Shipping Weight | 77 lb (35 kg) | |
| Unit Dimensions (WxHxD) | 6.37 x 9.50 x 18.2 in (16.18 x 24.13 x 46.22 cm) | |
| Shipping Dimensions | 14.50 x 22.0 x 25.0 in (36.83 x 55.88 x 63.50 cm) | |
| Unit Weight | 54.8 lb (24.8 kg) | |
| Shipping Weight | 61 lb (27.6 kg) | |
|
|
||
| UPS T2200 XR Specifications | ||
| Low-Voltage Models | T2200 XR | 204451-001 |
| Operating
Voltage Settings | 120V | |
| Power
Out (VA/Watts) | 1920/1600 | |
| Input
Connection |
Attached 6' power cord with NEMA 5-20P | |
| Output
Connection | (6) 5-15R & (2) 5-20R | |
| Load Segments | 2 | |
| NOTE: Part Number 204155-002 is user selectable for 110V, or 120V via front panel. | ||
| Extended Runtime Module Option | ERM, T1500/T2200
XR | 218969-B21 |
| Shipping Dimensions | 14.50 x 22.0 x 25.0 in (36.83 x 55.88 x 63.5 cm) | |
| Shipping Weight | 77 lb (35 kg) | |
| Unit Dimensions (WxHxD) | 8.1 x 9.50 x 18.8 in (20.6 x 24.13 x 47.8 cm) | |
| Shipping Dimensions | 15.5 x 20.5 x 26.0 in (39.37 x 52.07 x 66.04 cm) | |
| Unit Weight | 70 lb (31.7 kg) | |
| Shipping Weight | 80 lb (36.2 kg) | |
| | ||
| HP UPS T1000 XR, T1500 XR, and T2200 XR Specifications | ||
| Electrical Input | Voltage Range | 100, 120, 208 and 230V models. |
| Frequency | See Model Specifications for nominal and user selectable voltage settings | |
| Connections | 50/60 Hz | |
| Online
Efficiency | See Model
Selection Matrix 95% | |
| Surge Suppression | High Energy 6500A peak | |
| Electrical Output | Online Regulation | -30% to +20% of nominal voltage |
| On
battery Regulation | ±5% of nominal voltage | |
| Voltage
Wave Form | Sine wave | |
| Connections | See Model Specifications | |
| Output Protection | Re-settable circuit protectors | |
| Battery | Type | Maintenance-free, sealed, valve-regulated lead acid (VRLA) |
| Recharge
Time | <3 hours to 90% usable capacity; <24 hours for complete recharge | |
| Battery
String Voltage | T1000 XR: 24V (2x12V); T1500 XR: 48V (4X12V); T2200 XR: 48V (4X12V) | |
| Battery Ampere Hour (ah) | T1000 XR: 9ah; T1500 XR: 7.2ah; T2200 XR: 12ah | |
| Communications | Serial
Ports | Standard communication port (ships with communication cable) |
| LED Indicators | (11) LED status display with On Line, On Battery, Replace Battery, Overload Indicator, 76% to100% load, 51%to 75% load, 26% to 50% load, 0% to 25% load, Site Wiring Fault Indicator, General Alarm and Configure Mode On; (4) push button switches for On/Off, Alarm, Standby (turn output segments off), and Configure button | |
| Environmental and Safety | Operating
Temperature | 50° to 104° F (10° to 40° C) |
| Transit
and Storage Temperature | 5° to 131° F (-15° to 55° C) | |
| Humidity
(Operation) | 20% to 80% (non-condensing) | |
| Humidity
(Non-operating) | 5% to 95% | |
| Operating
Altitude | Up to 6,562 ft (2000 m) above sea level | |
| Transit
and Storage Altitude | Up to 30,000 ft (9,144 m) above sea level | |
| Audible
Noise | Less than 53 dBA | |
| Safety Markings | FCS, UL, CSA, VDE, NEMKO, FIMKO, DEMKO, SEMKO, NOM | |
| Safety
Certifications | UL1778; CSA22.2 | |
| EMC
Markings | FCC; CISPR; VCCI; CE | |
| Emissions | FCC CFR 47, Part 15 Class A, EN50091-2 | |
| Immunity | IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5 | |
| Surge Suppression | Conforms to IEEE 587B and ANSI C62.41 | |
| | ||
| Estimated Backup Times Chart (In Minutes) |
| Load (VA) |
UPS T1000 XR |
UPS T1500 XR |
UPS T2200 XR | ||||||
|
| UPS |
UPS+1ERM | UPS+2ERMs |
UPS | UPS+1ERM |
UPS+2ERMs | UPS |
UPS+1ERM | UPS+2ERMs |
| 200 |
35 | 160 |
300 | 60 |
230 | 415 |
44 | 197 |
380 |
|
250 | 31 |
140 | 276 |
54 | 215 |
390 | 42 |
190 | 364 |
| 300 |
28 | 124 |
255 | 50 |
196 | 360 |
40.5 | 183 |
349 |
|
350 | 24 |
105 | 234 |
46 | 185 |
335 | 39 |
175 | 330 |
| 400 |
21 | 90 |
212 | 42 |
170 | 310 |
37.5 | 165 |
312 |
|
450 | 17.5 |
75 | 194 |
38 | 155 |
284 | 36 |
160 | 300 |
| 500 |
14 | 60 |
170 | 34 |
140 | 255 |
35 | 154 |
384 |
|
550 | 13 |
56 | 155 |
30 | 125 |
228 | 32 |
146 | 369 |
| 600 |
11 | 52 |
138 | 26 |
110 | 200 |
31 | 139 |
350 |
|
650 | 9.5 |
47 | 120 |
22 | 95 |
174 | 29 |
132 | 335 |
| 700 |
8 | 43 |
104 | 17 |
79 | 146 |
27.5 | 124 |
319 |
|
750 | 6.5 |
38 | 88 |
16.5 | 75 |
140 | 26 |
116 | 302 |
| 800 |
6 | 35 |
70 | 16 |
72 | 132 |
24 | 108 |
285 |
|
850 | 5.75 |
32 | 65 |
15 | 69 |
126 | 21 |
102 | 269 |
| 900 |
5.5 | 30 |
62 | 14 |
65 | 120 |
19.5 | 93 |
251 |
|
950 | 5.25 |
27 | 58 |
13 | 61 |
114 | 18 |
86 | 238 |
| 1000 |
5 | 25 |
55 | 12 |
59 | 108 |
16 | 79 |
220 |
|
1200 | |
| |
9 | 44 |
81 | 13 |
56 | 170 |
| 1400 |
| |
| 7 |
37 | 69 |
11 | 49 |
136 |
|
1500 | |
| |
6.5 | 33 |
63 | 9.5 |
42 | 120 |
| 1800 |
| |
| |
| |
6 | 36 |
70 |
| 2000 |
| |
| |
| |
5.5 | 31 |
61 |
| 2200 |
| |
| |
| |
5 | 26 |
55 |
| NOTE: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions. |
| Compatibility | Compatible with all HP computer systems and servers ranging from individual workstations to distributed enterprise and other HP equipment (in tower form factor). | |
| | ||
|
© Copyright 2005 Hewlett-Packard Development Company, L.P. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. Unix is a registered trademark of The Open Group. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |