Overview
|
Compaq Power Distribution Unit (Zero-U/1U PDU) |
| Models |
| High Voltage PDU |
| 16A Model 207590-B21 (WW) |
| 24A Model 207590-D72 (NA/LA/JPN) |
| 32A
Model 207590-B31 (INTL) |
| 40A Model
207590-B23 (WW) |
| Low Voltage PDU |
| 24A Model 207590-D71 (NA/ LA/JPN) |
| Models Feature List:
|
| |
| Introduction |
|
The Compaq Power Distribution Units (PDUs) offer unparalleled power protection
and distribution for rack-mounted servers and server options. Compaq PDU
products manage power distribution in rack environments without consuming
valuable rack U-space. The new PDUs have a smaller form factor, which
allow them to be mounted in either a "zero-U" or "1U"
configuration, depending upon customer preference. Compaq PDUs provide
up to 12 output receptacles that distribute power within the rack cabinets.
Compaq single input PDUs are available in both High and Low Voltage models. |
|
|
| Key Features |
|
|
|
Product Highlights
| Small Form Factor with Flexible Mounting Options ("Zero-U" or "1U" Mounting Options) | The new Compaq Power Distribution Units have a smaller form factor that allows them to be mounted in either a "Zero-U" or "1U" configuration. This unique design provides managed power distribution for rack cabinets without sacrificing valuable rack space needed for business critical servers and storage requirements. Users can choose to mount their PDU in either a "Zero-U" configuration (which consumes no front-panel rack mounting space) or a "1U" configuration. | |
| | ||
| Consolidate and Maximize Cord Management | Provides up to 12 AC receptacles (circuit breaker protected) to distribute and consolidate power cords, and maximize cord management. |
|
| |
| Easy Installation | The new Compaq PDUs install
in either a zero-U or 1U configuration, offering maximum flexibility for utilizing
valuable rack space. The installation process is quick and easy. For zero-U mounting,
all required mounting brackets, accessories, and installation instructions are
shipped with the product. The 1U mounting brackets are available as a separate mounting kit, part number 215852-B21. | |
|
| ||
| Surge and Spike Protection | All Compaq Power Distribution Units are internally surge and spike protected. |
| | |
| Current Capacity | High voltage models of the Compaq PDUs range from 16A to 40A current capacity. One low voltage model is available with a 24A current capacity. |
|
| |
| Input Plugs | The 16A high voltage PDU (207590-B21)
has an IEC 320 C-20 input connection. This PDU also connects with the high voltage
models of UPS R3000 XR* and R6000. This SKU is available worldwide. The 24A high voltage PDU (207590-D72) has an L6-30 plug with non-detachable 12ft (4m) input power cord. This PDU is designed to connect directly into the facility AC input. This SKU is available in North America, Latin America, and Japan only. The 32A high voltage PDU (207590-B31) has an IEC 309 plug with a non-detachable 12ft (4m) input connection and is designed to connect directly into the facility AC input. This SKU is available in the International markets (Europe, Middle East and Africa, China, and Asia Pacific). The 40A high voltage PDU (207590-B23) is hard wired. This SKU is available in the worldwide markets. The 24A low voltage PDU (207590-D71) has an L5-30 non-detachable 12ft (4m) power cord. This PDU connects to the low voltage UPS R3000 XR. This SKU is available in North America, Latin America, and Japan. |
| | |
| Compatibility | Designed to fit into the Compaq rack cabinets. Flexible "zero-U" or "1U" mounting options, allow customers to fully populate the rack with critical computing hardware, saving rack and floor space in the customer's environment. |
| | |
| Warranty | Covered
by a three-year limited warranty. Warranty covers failure of the Power Distribution
Unit during the warranty period. NOTE: Some restrictions and exclusions apply. Consult the Compaq Customer Support Center at 800-345-1518 for details. |
|
|
Service and Support, HP Care Pack and Warranty Information
| Warranty Upgrade Options | Response Upgrade on-site response from next business day to same day 4 hours |
| Coverage Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days | |
| Duration Select duration of coverage for a period of 1, 3, or 5 years | |
| | |
| HP Care Pack Information | For
additional HP Care Pack (hardware & software) information, as well as orderable
part numbers, please refer to the URL listed below: http://h18005.www1.hp.com/services/carepaq/index.html | |
| UPS's up
to 3KVA; and all PDU's have services covered under the services for Racks/Cabinets, Enclosures | 9x5 Next-Business-Day On-Site Coverage 3 Years | FM-CBXHW-36 |
| 9x5 4-Hour Response On-Site Coverage 3 Years | FM-CB4HR-36 | |
| 24x7, 4-Hour Response On-Site Coverage 3 Years | FM-CB724-36 |
|
|
Compaq Power Distribution Unit Specifications
| Application Information |
| High
Voltage 16A | High
Voltage 24A | High
Voltage 32A | High
Voltage 40A | Low
Voltage 24A | |
| Part
Number | 207590-B21 |
207590-D72 |
207590-B31 |
207590-B23 |
207590-D71 |
| UPC
Code | 720591497637 |
720591546571 | 720591497644 |
720591497668 | 720591546564 |
| AC Voltage Input |
200 to 240 | 200
to 240 | 200 to
240 | 200 to 240 |
100 to 127 |
| AC
Voltage Output | 200
to 240 | 200 to
240 | 200 to 240 |
200 to 240 | 100
to 127 |
| Hertz | 50/60 |
50/60 | 50/60
| 50/60 |
50/60 |
| Current (Max) | 16A |
24A | 32A |
40A | 24A |
| Circuit Breaker |
2 for each 2-pole 10A |
4 for each 2-pole 10A |
4 for each 2-pole 10A |
2 for each 2-pole 10A 3 for each 2-pole |
15A 4 for each 1-pole 15A |
| Operating Temperature |
32° to 122° F (0° to 50° C) |
32° to 122° F (0° to 50° C) |
32° to 122° F (0° to 50° C) |
32° to 122° F (0° to 50° C) |
32° to 122° F (0° to 50° C) |
| Power Cable-AWG, Length & Plug Type | Detachable
power cord. Kit includes 1x16A jumper cord and 2x10A jumper cords |
12 ft L6-30 attached power cord. Kit includes 2x10A jumper
cords | 12 ft IEC
309-32A attached power cord. Kit includes 2x10A jumper cords |
Field wired. Kit includes 1x16A jumper cord and 2x10A jumper
cords | 12 ft NEMA
L5-30 attached power cord |
| Input
Connection | IEC
320 C-20 | NEMA
L6-30P | IEC 309-32A |
None | NEMA
L5-30P |
| Output Connection | 12 for
each IEC 320 C-13 | 12
for each IEC 320 C-13 | 12
for each IEC 320 C-13 | 6
for each IEC 320 C-13 3 for each IEC 320 C-19 |
12 for each NEMA 5-15R |
| Surge Suppression Clamping Level |
275 to 320V RMS |
275 to 320V RMS |
275 to 320V RMS |
275 to 320V RMS |
275 to 320V RMS |
| Surge
Current | 10,000
amps per unit | 10,000
amps per unit | 10,000
amps per unit | 10,000
amps per unit | 10,000
amps per unit |
| Spike Protection | 500 joules,
10 x 1000 usec | 500
joules, 10 x 1000 usec | 500
joules, 10 x 1000 usec | 500
joules, 10 x 1000 usec | 500
joules, 10 x 1000 usec |
| Shipping
Weight | 13 lb
(5.9 kg) | 17 lb
(7.7 kg) | 17 lb
(7.7 kg) | 14 lb
(6.4 kg) | 17 lb
(7.7 kg) |
| Mechanical Weight | 7 lb (3.2
kg) | 11 lb (5.0
kg) | 11 lb (5.0
kg) | lb (3.2 kg) |
11 lb (5.0 kg) |
| Mechanical Dimensions (WxHxD) | 17.0 x 1.65 x 8.0 in (43.18 x 4.19 x 20.32 mm) |
| Shipping Dimensions (WxHxD) | 20.5 x 7.9 x 13.9 in (52.07 x 20.07 x 35.31 cm) |
| Conformance Standards | UL, CUL, CE, NOM - 16A model and
40A model UL, CUL, NOM - 24A High and Low voltage models CE - 32A model |
| Kit Contents | Power
Distribution Unit 0U Mounting brackets and hardware Cord Retention hardware Tie wraps High voltage models are shipped with two IEC-320 10A jumper cables Models 207590-B21 and 207590-B23 are also shipped with one IEC-320 16A jumper cable |
| 1U/0U Mounting Kit sold separately, Part Number, 215852-B21. | |
|
|
Family Information
|
| PDU
High Voltage 16A | PDU
High Voltage 24A | PDU
High Voltage 32A | PDU
High Voltage 40A | PDU
Low Voltage 24A |
|
Part Number |
207590-B21 |
207590-D72 |
207590-B31 |
207590-B23 |
207590-D71 |
|
Form Factor |
Rack-mountable, "zero-U"/"1U" |
Rack-mountable, "zero-U"/"1U" |
Rack-mountable, "zero-U"/"1U" |
Rack-mountable, "zero-U"/"1U" |
Rack-mountable, "zero-U"/"1U" |
| Input Connection
(Single Input) | IEC
320 c-20 (Detachable line cord) |
NEMA L6-30P |
IEC 309-32A |
Field Wired Terminal |
NEMA L5-30P |
|
Output Connections |
(12) IEC 320 C-13 |
(12) IEC 320 C-13 |
(12) IEC 320 C-13 |
(6) IEC 320 C-13 (3) IEC 320 C-19 |
(12) NEMA 5-15R |
|
Applications |
Connects to high voltage models of the UPS R3000 XR* and R6000. |
Designed to connect directly into the facility input. |
Designed to connect directly into the facility input. |
May be hardwired into the facility input or a high voltage UPS. |
Connects to low voltage models of the UPS R3000 XR (and may
also be connected directly into the facility input). |
|
Availability |
Available Worldwide |
Available in North America, Latin America, and Japan |
Available in Europe and Middle East, and Asia Pacific regions |
Available Worldwide |
Available in North America, Latin America, and Japan |
| Cable | Description | Part
Number | |
| Additional
PDU Cables Available | 6.6 ft (2.0 m) | 10A, IEC C14 to IEC C13 Connects to the device input power connection | 142257-001 |
| 8 ft (2.5 m) | 142257-002 | ||
| 10 ft (3.0 m) | 142257-003 | ||
| 12 ft (3.6 m) | 142257-004 | ||
| Single
cable for NA/LA Y-cables pack of 20 cables for NA/LA | Remote Insight Lights-Out Edition (RILOE) power cable has been designed for plugging into Compaq high-line PDUs. One single high-line PDU cable supports two RILOE cards, which reduces the number of plugs required on the PDU for connecting the RILOE cards. The Compaq high-line PDU does not support the standard RILOE power cord that ships in the RILOE kits. | 201493-001 | |
201493-002 |
| ©
Copyright 2003 Hewlett-Packard Development Company, L.P. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |