Overview
|
HP Smart Array 5312 Controller |
|||
| Models | |||
| 238633-B21 238633-291 (Japan) |
|||
| Feature List: | |||
|
|
|
|
Introduction |
||
| The Smart Array 5312 (SA-5312) high-performance,
dual channel Ultra3, PCI-X array controller provides reliable data protection
for ProLiant™ servers and offers flexibility thanks to an innovative
modular design. The SA-5312 controller raises the standard to higher performance
levels with several enhancements including enhanced memory architecture
and RAID engine. Designed and tested with industry-standard ProLiant Servers for greater reliability, this controller is ideal for the distributed workgroup server or centralized departmental server, and like other Smart Array controllers, the SA-5312 offers complete data compatibility with previous generations' Smart Array controllers for easy data migration and upgradability. |
||
|
|
| What's New | ||||||||
| Updated option support list, maximum storage support. | ||||||||
|
|
||||||||
| Key Features | |
|
|
|
|
| The Smart Array Advantage | |
| HP's innovative design and integration work of the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID products. The HP Smart Array family brings an unparalleled return on investment through: | |
| Data Compatibility among all models of Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase. Even successive generations of Smart Array controllers understand the data format of other Smart Array Controllers. | |
| Consistent Configuration and Management Tools. All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the ProLiant server storage. | |
| Universal Hard Drive form factor is for use across multiple ProLiant servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives. | |
| Pre-Failure Warranty means Insight Manager™ not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center or refer to your ProLiant Server documentation. | |
|
|
|
Software Suite |
|
| All Smart Array products share a common set of configuration, management and diagnostic tools, including Array Configuration Utility (ACU-XE), Array Diagnostic Utility (ADU), and Insight Manager. This software consistency of tools reduces the cost of training for each successive generation of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain the HP server storage. | |
| Insight Manager | |
|
|
| Configuration/Diagnostic Utilities | |
|
|
|
|
Compatibility
| Servers | |
| For up to date compatibility, please see
the following URL for complete Smart Array 5312 compatibility and support
information. http://www.hp.com/products/smartarray |
|
| NOTE: The SA-5312 is not supported in 5 volt PCI slots | |
|
|
| Operating Systems | |
| Microsoft® Windows NT® 4.0, 2000
** Novell® NetWare® 4.2, 5.x ** Linux® |
|
|
Product Highlights
|
Data Compatibility |
Data compatibility among all models of Smart Array Controllers means customers can instantly upgrade their Smart Array products to get to higher performance, capacity and availability. Unlike competitive products, successive generations of Smart Array products understand the data format of other Smart Array controllers, providing investment protection for your HP storage solution. | ||
|
|
|||
|
Affordable |
HP's new high-performance architecture sets new boundaries of industry performance expectations! | ||
|
|||
|
|
|||
|
Capacity |
|
||
|
|
|||
| Availability | Provides increased server uptime by providing advanced storage functionality: | |
|
||
|
|
||
|
Fault Prevention |
The following features offer detection of possible failures before they occur, allowing preventive action to be taken: | ||
|
|||
|
|
|||
|
Fault Tolerance |
Keeps data available and server running while a failed drive is being replaced; several fault tolerance configurations are supported including: | ||
|
|||
|
|
|||
|
Fault Recovery |
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure | ||
|
|||
|
|
|||
|
Ease of Use |
Consistency and Upgradability make the Smart Array family unique in the industry: |
|
|
|
Service and Support, HP Care Pack and Warranty Information
| Software Product Services |
Standalone telephone support
|
| Rights to new license version | |
| Media and documentation updates | |
|
|
|
| Hardware Product Services | Installation services |
| On-site maintenance (includes warranty support) | |
| Response time upgrades during the warranty period | |
| Post-warranty coverage | |
| RAID setup and performance consulting via statement of work | |
| For additional hardware installation
and maintenance information, please refer to the URL listed below: http://www.hp.com/hps/hardware/ |
|
|
|
|
| Warranty Upgrade Options | Response - Upgrade on-site response from next business day to same day 4 hours |
| Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days | |
| Duration - Select duration of coverage for a period of 1, 3, or 5 years | |
|
|
|
| HP Care Pack Information | HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. | |
| HP Care Pack is not available for less than the product's warranty duration. | ||
| HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required. | ||
| HP Care Pack services are prepaid. | ||
| For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL http://www.hp.com/hps/carepack/ | ||
|
|
||
| Components | The following brick level options/components do not have individual HP Care Pack Services. These items will be included in product HP Care Pack Services into which they are installed. | ||||
| Disk Drives | Tape Drives | CD/DVD ROM | SCSI Hubs in SBBs | Adapters | |
| Bus Converters | Backplane RAID Controllers | Power Supplies | Cabling | Fans | |
|
|
Options
| Controller Upgrade Options | 256 MB Battery-Backed
Cache Module NOTE: This 256 MB Battery-Backed Cache Module supports the Smart Array 5300 series controllers, MSA 1000 and the Smart Array Cluster Storage |
254786-B21 | ||
|
|
||||
| Software | StorageWorks™ Virtual Replicator by HP | |||
| License & Media (CD-ROM) | 388931-B21 | |||
| License Only | 388932-B21 | |||
|
|
||||
| Disk Drive Enclosures | StorageWorks Enclosure 4314T | 190210-001 | ||
| StorageWorks Enclosure 4314T (Int'l) | 190210-B31 | |||
| StorageWorks Enclosure 4314T (Japan) | 190210-291 | |||
| StorageWorks Enclosure 4314R | 190209-001 | |||
| StorageWorks Enclosure 4314R (Int'l) | 190209-B31 | |||
| StorageWorks Enclosure 4314R (Japan) | 190209-291 | |||
| StorageWorks Enclosure 4354R | 190211-001 | |||
| StorageWorks Enclosure 4354R (Int'l) | 190211-B31 | |||
| StorageWorks Enclosure 4354R (Japan) | 190211-291 | |||
|
|
||||
| Hard Drives | Wide Ultra3 SCSI Universal Drives Hot Plug | |||
| 36.4-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") | 232916-B22 | |||
| 18.2-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") | 188122-B21 | |||
| 9.1-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") | 188120-B21 | |||
| 72.8-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 232432-B22 | |||
| 36.4-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 176496-B22 | |||
| 18.2-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 142673-B22 | |||
| 9.1-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 142671-B22 | |||
| 36-GB Wide Ultra3 SCSI 10,000 rpm Drives (1"), 10 pack | 232617-B21 | |||
| 18-GB Wide Ultra3 SCSI 10,000 rpm Drives (1"), 10 pack | 202352-B21 | |||
| Ultra320 Universal Drives Hot Plug | ||||
| 36.4GB 10,000 rpm, U320 Universal Hard Drive, 1" | 286713-B22 | |||
| 72.8GB 10,000 rpm, U320 Universal Hard Drive, 1" | 286714-B22 | |||
| 146.8GB 10,000 rpm, U320 Universal Hard Drive, 1" | 286716-B22 | |||
| 18.2GB 15,000 rpm, U320 Universal Hard Drive, 1" | 286775-B22 | |||
| 36.4GB 15,000 rpm, U320 Universal Hard Drive, 1" | 286776-B22 | |||
| 72.8GB 15,000 rpm, U320 Universal Hard Drive, 1" | 286778-B22 | |||
| NOTE: This is a list of supported hard disk drives (note that some drives may be discontinued). | ||||
| NOTE: For complete compatibility information, refer to the SCSI Hard Drive Compatibility table located at: http://www.compaq.com/products/servers/proliantstorage/drives-enclosures/docs/index.html | ||||
|
|
||||
| Universal Hot Plug Tape Drives | AIT 100 GB, Hot Plug (Carbon) | 249161-B21 | |
| AIT 50 GB, Hot Plug (Carbon) | 215487-B21 | ||
| AIT 35 GB, LVD Hot Plug (Carbon) | 216886-B21 | ||
| 20/40-GB DAT, Hot Plug (Carbon) | 215488-B21 | ||
|
|
Technical Specifications
| Electrical Interface | LVD (Low Voltage Differential) | ||
| Protocol Support | Wide Ultra3 SCSI (160 MB/s per channel) | ||
| SCSI Ports | 2 external/2 internal shared | ||
| Drives Supported | Up to 28 drives | ||
| Maximum Capacity | 4.1 TB (28 drives x 146.8 GB Ultra320) | ||
| PCI | PCI-X and 3.3 volt
PCI compatibility only NOTE: The SA-5312 is not supported in 5 volt PCI slots. |
||
| PCI Bus Speed | 64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth) | ||
| Logical Drives | Up to 32 logical drives | ||
| RAID Support | RAID 5 (Distributed Data Guarding) | ||
| RAID 1+ 0 (Striping & Mirroring) | |||
| RAID 0 (Striping) | |||
| Cache Memory | 128 MB Read/Write (256-MB module upgrade available) | ||
| ECC protection, battery-backed, and removable | |||
| Cache Batteries | Up to 4 days of redundant battery life (72hrs. for the 256-MB module) removable for easy replacement | ||
| Upgradable Firmware | 2-MB flashable ROM | ||
| Disk Drive and Enclosure Protocol Support |
Ultra3 & Ultra2 | ||
| Memory Addressing | 64-bit, supporting servers memory greater than 4 GB | ||
| Dimensions (HxWxD) | 18.375 x 8.25 x 4 in/46.67 x 20.95 x 10.16 cm | ||
| Weight | Smart Array 5312 | 3.26 lb/1.48 kg | |
|
|
|||
| Family Information | |||
| Smart Array 5312 | Smart Array 5300 | ||
| Stripe Set Migration | Yes | Yes | |
| RAID Level Migration | Yes | Yes | |
| Redundant Controllers | No | No | |
| Online Spare Support | Yes | Yes | |
| Capacity Extension | Yes | Yes | |
| SAN Access Module | No | Yes | |
| PCI Bus | 64-bit, 133-MHz PCI-X | 64-bit, 66-MHz | |
|
|
|||
| © Copyright 2003 Hewlett-Packard Development
Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |