|
|
Overview
|
HP AlphaServer GS80 (1224 MHz)
|
| At A Glance |
AlphaServer GS80 systems include:
|
|
|
Standard Features
| Processor | Up to eight Alpha 21264 6/1224-MHz CPUs (one CPU per module) | ||
|
|
|||
| Cache Memory | 64-K I and D caches on-chip; 16-MB ECC on-board cache per CPU | ||
|
|
|||
| Architecture | AlphaServer GS80
utilizes a modular crossbar switch structure AlphaServer GS80 uses either one or two system drawers as building blocks. Each drawer houses a Quad building block (QBB) system module, which supports up to four CPUs, four memory modules, and eight PCI buses on a 7-GB/s non-blocking backplane switch Up to two system drawers are connected by a direct internal interconnect with 3.3-GB/s of bandwidth |
||
|
|
|||
| CPUs, Memory, and I/O Slots | Base systems contain one CPU and one master PCI I/O drawer | ||
| Model 4 | Model 8 | ||
| Maximum CPUs supported | 4 | 8 | |
| Maximum memory supported | 32 GB (4 modules) | 64 GB (8 modules) | |
| Maximum PCI slots supported | 28 | 56 | |
| NOTE: Model 4 and Model 8 base systems include 12 configurable PCI slots. System capacities shown are available with both Tru64 UNIX and OpenVMS operating systems. | |||
|
|
|||
| Network and I/O Controllers | Ethernet | PCI Dual 10/100 Mbit Fast Ethernet adapter (DE602) included in master PCI shelf box; additional Ethernet adapters available as options | |
| Console ports | One bi-directional parallel port with 25-pin D-subminiature connector | ||
| Two EIA-232 full duplex asynchronous
modem control serial ports, 9-pin D-subminiature connectors |
|||
| One PS/2 compatible keyboard port; one PS/2 compatible mouse port | |||
|
|
|||
| Boot/Diagnostic Devices | Boot/diagnostic devices included in master PCI shelf box | |
| CD-ROM | One 5.25-inch half height 600-MB CD-ROM drive | |
| Hard Drives | One 18.2-GB 10,000 rpm SCSI disk drive | |
|
|
||
| Internal Disk Expansion | Total Internal Drive Bays | Up to 14 146-GB drives (2,044 GB) can be mounted in one optional storage shelf in the system cabinet | |
|
|
|||
| Power Supplies | Single-phase power subsystem
with power cords; optional redundant 48 VDC hot swap power supplies |
||
|
|
|||
| OS Support | Tru64 UNIX systems include preinstalled software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server |
| NOTE: Tru64 UNIX refers to versions 4.0G, 5.1, 5.1A, 5.1B, or later. Refer to the "Supported Options List" - http://www.hp.com/alphaserver/products/options.html for any unique limitations based on OS version. | |
| OpenVMS systems include preinstalled software, Base license and Enterprise Integration Package V3.0 | |
| Support for up to two total instances of Tru64 UNIX or OpenVMS, or a combination of both, in hardware partitions on a single AlphaServer GS80 Model 8 hardware platform | |
| NOTE: OpenVMS refers to versions 7.2-1H1, 7.2-2, 7.3, 7.3-1, or later. Refer to the "Supported Options List" - http://www.hp.com/alphaserver/products/options.html for any unique limitations based on OS version. | |
|
|
|
| Service and Support | Protected by HP Services including a one-year on-site hardware warranty. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support. |
|
|
Systems
| Step 1 - Assess Application Requirements |
|
|
NOTE: Most configuration steps require that these data be considered in whole or in part. Be sure to execute each step in the context of the total application requirements. |
| System Ordering Requirements: |
| Certain system components or services are either required for normal operation or are recommended for best system performance and/or operation. This document uses the following definitions to specify these options: |
|
|
|
Step 2 - Select base system |
|
|
|
|
| AlphaServer GS80 systems require selection of the following items: | |
|
Mandatory Purchases:
|
|
|
Required Options and Services:
|
|
|
Recommended Services:
|
|
| NOTE: The base system package should be selected in the context of the number of hardware partitions required, the total capacity required, and the anticipated near-term system growth. | |
|
|
|
|
AlphaServer GS80 (1224-MHz) Base Systems
|
||||||
| Model | OS | Drawers (QBBs) Included | Total CPUs Supported | Geography | Input Power | Order Number |
| Model 4 | Tru64 UNIX | 1 | 4 | U.S./Canada | 120V | DA-A80AG-AC |
| Model 4 | Tru64 UNIX | 1 | 4 | Europe | 220-240V | DA-A80AG-AD |
| Model 4 | Tru64 UNIX | 1 | 4 | Japan | 200-240V | DA-A80AG-AE |
| Model 4 | OpenVMS | 1 | 4 | U.S./Canada | 120V | DY-A80AG-AC |
| Model 4 | OpenVMS | 1 | 4 | Europe | 220-240V | DY-A80AG-AD |
| Model 4 | OpenVMS | 1 | 4 | Japan | 200-240V | DY-A80AG-AE |
| Model 8 | Tru64 UNIX | 2 | 8 | U.S./Canada | 120V | DA-A80BG-AC |
| Model 8 | Tru64 UNIX | 2 | 8 | Europe | 220-240V | DA-A80BG-AD |
| Model 8 | Tru64 UNIX | 2 | 8 | Japan | 200-240V | DA-A80BG-AE |
| Model 8 | OpenVMS | 2 | 8 | U.S./Canada | 120V | DY-A80BG-AC |
| Model 8 | OpenVMS | 2 | 8 | Europe | 220-240V | DY-A80BG-AD |
| Model 8 | OpenVMS | 2 | 8 | Japan | 200-240V | DY-A80BG-AE |
|
|
Step 3 - Additional SMP CPUs |
||
|
|
||
|
||
| GS80 SMP upgrade CPU, 68/1224-MHz with 16-MB on-board cache, Tru64 UNIX | 3X-KN8AC-AB | |
| GS80 SMP upgrade CPU, 68/1224-MHz with 16-MB on-board cache, OpenVMS | 3X-KN8AC-AC | |
|
|
||
| HP Capacity on Demand (CoD) CPUs |
|
|
| GS80 CoD SMP CPU, includes one 68/1224-MHz CPU module with 16-MB on-board cache, Tru64 UNIX SMP license, and CoD program license |
3X-KN8CC-AB
|
|
| GS80 CoD SMP CPU, includes one 68/1224-MHz CPU module with 16-MB on-board cache, OpenVMS SMP license, and CoD program license |
3X-KN8CC-AC
|
|
|
Options
| Step 4 - Select Memory Options | ||
|
|
||
|
||
| 0.5-GB GS80/160/320 base memory module |
3X-MS8AA-AB
|
|
| 0.5-GB GS80/160/320 memory DIMM upgrade |
3X-MS8AA-AU
|
|
| 1-GB GS80/160/320 base memory module |
3X-MS8AA-BB
|
|
| 1-GB GS80/160/320 memory DIMM upgrade |
3X-MS8AA-BU
|
|
| 2-GB GS80/160/320 base memory module |
3X-MS8AA-CB
|
|
| 2-GB GS80/160/320 memory DIMM upgrade |
3X-MS8AA-CU
|
|
| 4-GB GS80/160/320 base memory module |
3X-MS8AA-DB
|
|
| 4-GB GS80/160/320 memory DIMM upgrade |
3X-MS8AA-DU
|
|
|
|
||
| Memory Configuration Guidelines | ||
| Memory options should be selected in the
context of the application's sensitivity to memory bandwidth and memory
capacity, and the number of hardware partitions. This will determine the
number of memory base modules and upgrades needed. The total capacity required
will determine the size of the arrays to be chosen. The configuration of memory may influence the performance of applications, and there are numerous ways to configure the choices of memory base modules and upgrade DIMMs. The following general guidelines can lead to several configuration choices. Application-specific guidelines will help narrow down the choices. |
||
|
||
|
|
| Memory Application Examples | ||
| Configuring memory is a compromise between cost, total memory capacity, and memory bandwidth requirements. The behavior of the application must be used to define the most-desired configuration. Some applications are sensitive to memory capacity, some are sensitive to memory bandwidth, and some are sensitive to neither. If actual application measurements are not available, the following may be used as guidelines: | ||
|
||
| The following table represents how 8 GB could be configured in a 4-CPU QBB system drawer in each of the four referenced applications. The numbers under each application represent how many of each memory option should be ordered. | ||
|
|
|
Memory Configuration Examples Configuring
a system drawer with a total of 8 GB for specific applications
|
|||||
|
|
|
Application
|
|||
|
VLM
|
OLTP, Timesharing
|
Data Mining
|
HPTC
|
||
|
1-GB base module
|
(3X-MS8AA-BB)
|
-
|
-
|
-
|
4
|
|
1-GB upgrade
|
(3X-MS8AA-BU)
|
-
|
-
|
-
|
4
|
|
2-GB base module
|
(3X-MS8AA-CB)
|
2
|
2
|
4
|
-
|
|
2-GB upgrade
|
(3X-MS8AA-CU)
|
2
|
2
|
-
|
-
|
|
|
|
|
|
|
|
|
The following additional configuration options utilizing
the 4-GB base module are available:
|
|||||
|
4-GB base module
|
(3X-MS8AA-DB)
|
2
|
2
|
N/R
|
N/R
|
|
4-GB upgrade
|
(3X-MS8AA-DU)
|
-
|
-
|
||
|
NOTE: N/R = Not recommended - For these applications, configure either four or eight like-sized memory options rather than one or two. |
|||||
| Step 5 - Evaluate Configuration Requirements to Support Optional Partitioning |
||
|
|
||
| Configuration Requirements for Partitions | ||
|
||
| Minimum Hardware Required per AlphaServer GS80 Hardware Partition | ||
| Each hardware partition requires one system drawer and that drawer must be configured with the minimum hardware listed below. Each system drawer can be configured with additional hardware once this minimum requirement is met. | ||
|
||
| Optimizing System Resources | ||
| The following configuration guidelines can be used to improve performance in systems or in each partition of a hardware-partitioned system. | ||
|
||
| System Software Required for AlphaServer GS80 Hardware Partition Support | ||
| Software Licensing for Hardware Partitions | ||
|
||
| User and capacity-based licensing is unaffected by hardware partitions. Examples: | ||
|
||
| Licensing Partitioned AlphaServer GS80 Systems for Both OpenVMS and Tru64 UNIX | ||
|
||
| OpenVMS software upgrade for GS80 |
QB-63PAG-AG
|
|
| Tru64 UNIX software upgrade for GS80 |
QB-595AM-AA
|
|
|
||
| OpenVMS Alpha SMP license for GS80 |
QL-MT1A9-6Q
|
|
| Tru64 UNIX Alpha SMP license for GS80 |
QL-MT4A9-6Q
|
|
|
||
| Example 1: 8-CPU GS80 system in which all processors are licensed for both OpenVMS and Tru64 UNIX: | ||
|
||
| Example 2: 8-CPU GS80 system in which all the processors are licensed for Tru64 UNIX and four processors are also licensed for OpenVMS: | ||
|
||
|
|
||
| Step 6 - Configure Packaging Options |
||
|
|
Step 6a - Redundant (N+1) Power Supplies |
||
|
|
||
|
||
| 1000W 48V power supply | H7510-BA | |
|
|
||
Step 6b - Internal System Expansion |
||
|
|
||
|
||
|
|
| Internal StorageWorks Expansion |
|
|
|
|
||
| Configuring DS-SL13R-xx Ultra3 (LVD) Shelves |
|
|
| StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, International except Japan |
DS-SL13R-AA
|
|
| StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, Japan |
DS-SL13R-AJ
|
|
| StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, International except Japan |
DS-SL13R-BA
|
|
| StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, Japan |
DS-SL13R-BJ
|
|
| NOTE: Model 4314 shelf with DS-KZPCC-CE RAID controller does not support a disk drive in the last slot. | ||
|
|
||
| Power Option for DS-SL13R-xx Shelves |
|
|
| Redundant power supply for 4314R Ultra3 (LVD) StorageWorks shelf, North America |
DS-SE2UP-BA
|
|
| Redundant power supply for 4314R Ultra3 (LVD) StorageWorks shelf, International |
DS-SE2UP-BI
|
|
|
|
||
| System I/O Expansion |
|
|
|
|
||
| PCI Drawer Expansion |
|
|
| Master PCI shelf mount box for system and I/O expansion cabinets with standard I/O PCI module and 13 PCI expansion slots. (The 1st master comes standard with all systems and includes a standard dual Ethernet network card and the system module and cable pair for connection to the system drawer). |
3X-DWWPA-AA
|
|
| Expansion PCI shelf mount box for system and I/O expansion cabinets with 14 PCI expansion slots |
3X-DWWPA-BA
|
|
| System I/O module for connecting to master or expansion PCI shelves |
3X-KFWHA-BA
|
|
| I/O module cable for connection between I/O module and master or expansion PCI shelves is mounted in system cabinet; two are mandatory per system I/O module |
BN39B-04
|
|
|
|
||
| Step 6c - External Expansion Cabinets | ||
|
|
||
|
||
| Black I/O expansion cabinet for use with GS80 systems, includes two 120V single-phase power controllers and cords for use in U.S. and Canada does not support dual AC input configurations |
3X-H9A20-AD
|
|
| Black I/O expansion cabinet for use with GS80 systems, includes two 220-240V single-phase power controllers and cords for use in Europe supports dual AC input configurations |
3X-H9A20-AE
|
|
| Black I/O expansion cabinet for use with GS80 systems, includes two 200-240V single-phase power controllers and cords for use in U.S., Canada, and Japan supports dual AC input configurations |
3X-H9A20-AF
|
|
|
||
| Black end-panel trim kit for remote 3X-H9A20-AD/AE/AF cabinets |
CK-H9A20-AB
|
|
| I/O module cables for connection between I/O module and master or expansion PCI drawers mounted in 3X-H9A20-AD/AE/AF expansion cabinet adjacent to system; two cables (BN39B-07 or BN39B-10) are mandatory per PCI drawer |
BN39B-07
|
|
| I/O module cables for connection between I/O module and master or expansion PCI drawers mounted in second expansion cabinet or in remote 3X-H9A20-AD/AE/AF expansion cabinets; two cables (BN39B-07 or BN39B-10) are mandatory per PCI drawer |
BN39B-10
|
|
|
|
||
| Step 7 - Storage |
||
|
|
| Step 7a - Storage Adapters and Controllers |
|
|
|
| NOTE: "Per System" quantities apply to systems or to each hardware partition. The SCSI adapters included in the base system or in 3x-DWWPA-AA master PCI drawers must be included in this calculation. |
|
|
| Maximum # Supported | |||||||
| Tru64 UNIX | OpenVMS | ||||||
|
Per System
|
Per
System Drawer |
Per PCI Drawer
|
Per System
|
Per
System Drawer |
Per PCI Drawer
|
||
|
Fibre Channel
|
|||||||
|
PCI Fibre Channel adapter (uses one PCI slot); requires
Fibre Channel with SC connector for adapter
|
26/54*
|
26/26*
|
13
|
26
|
26
|
13
|
DS-KGPSA-CA
|
|
2-GB PCI-X Fibre Channel adapter
|
26/32* | 26 | 12 | 26 | 26 | 12 |
DS-KGPSA-EA
|
|
Fibre Channel SC-SC cable (BNGBX-xx),
xx=02, 03, 05, 10, 15, 30, 50 meters |
BNGBX-xx
|
||||||
|
Fibre Channel SC-LC cable, 2-meter (2976), 5-meter (2977),
15-meter (2978), 30-meter (3458), 50-meter (3459)
|
3R-Axxxx-AA
|
||||||
|
Fibre Channel LC-LC cable, 2-meter (2979), 5-meter (2980),
15-meter (2981), 30-meter (3454), 50-meter (3455)
|
3R-Axxxx-AA
|
||||||
|
SCSI
|
|||||||
|
PCI 1-port UltraSCSI differential host adapter (uses one
PCI slot); requires BN38C-xx cable
|
24/54*
|
24/26*
|
12/13*
|
24
|
24
|
12
|
3X-KZPBA-CC
|
|
VHDCI male-to-68-pin HD male UltraSCSI cable
xx=02, 05, 10, 20 (use -02 for connecting SCSI adapter to SCSI devices when both the PCI shelf and StorageWorks shelf are in the system cabinet or in an adjacent expansion cabinet; use -05, -10, and -20 for connecting SCSI adapter to SCSI devices when the PCI shelf and StorageWorks shelf are in two different cabinets) |
BN38C-xx
|
|
PCI 1-port Ultra 2 (LVD) SCSI adapter, 32-bit, single-channel
(uses one PCI slot); includes external 68-pin HD connectors; requires
BN38C-xx cable to connect adapter to Ultra2 or Ultra3 shelf; HSZxx RAID
controllers not supported
|
8 | 8 | 8 | 8 | 8 | 8 |
3X-KZPCA-AA
|
|
68-pin HD male-to-VHDCI male UltraSCSI cable;
xx=02, 03, 05, 10, 20 meter |
BN38C-xx
|
|
PCI 2-channel Ultra3 (LVD) SCSI adapter, 64-bit/66-MHz
(uses one PCI slot); includes internal 68-pin HD and external 68-pin VHDCI
connectors; requires 3X-BC56J-xx cable to connect adapter to DS-SL13R-Bx/
DS-SSL14-xx Ultra3 shelf.
NOTE: OpenVMS 7.2-2, or later, is required; Tru64 UNIX 5.1B PK4, or later is required, maximum cable length is 12 meters. |
4 | 4 | 4 | 4 | 4 | 4 |
3X-KZPEA-DB
|
|
68-pin VHDCI male-to-VHDCI male UltraSCSI cable;
xx=02, 03, 04, for 6, 12, & 24 meters respectively |
3X-BC56J-xx
|
|
RAID
|
|||||||
|
PCI 2-port PCI to Ultra3 64-bit, 66-MHz, LVD backplane
RAID controller with 128-MB cache (uses one PCI slot); requires connection
to DS-SL13R-xx shelves.
NOTE: No host-based volume shadowing or shared bus support under OpenVMS. |
8 | 8 | 4 | 8 | 8 | 4 |
3X-KZPDC-BE
|
|
PCI 4-port PCI to Ultra3 64-bit, 66-MHz, LVD backplane
RAID controller with 256-MB cache (uses one PCI slot); requires connection
to DS-SL13R-xx shelves.
|
8 | 8 | 4 | 8 | 8 | 4 |
3X-KZPDC-DF
|
|
PCI 1-channel Ultra2 (LVD) SCSI RAID controller, 16-MB
cache, (uses one PCI slot); supports 14 disks per channel with DS-SL13R-xx
Ultra3 shelves; requires BN37A-xx cable to connect adapter to DS-SL13R-xx
Ultra3 shelf.
|
8** | 8 | 8 | - | - | - |
DS-KZPCC-AC
|
|
PCI 3-channel Ultra2 (LVD) SCSI RAID controller, 64-MB
cache, (uses one PCI slot); supports 14 disks per channel with DS-SL13R-xx
Ultra3 shelves; requires BN37A-xx cable to connect adapter to DS-SL13R-xx
Ultra3 shelf.
|
8** | 8 | 8 | - | - | - |
DS-KZPCC-CE
|
|
PCI 2-channel Ultra3 (LVD) SCSI RAID controller**,
128-MB cache, (uses one PCI slot); supports 14 disks per channel with
DS-SL13R-xx Ultra3 shelves; requires BN37A-xx cable to connect adapter
to DS-SL13R-xx Ultra3 shelf.
|
8 | 8 | 8 | - | - | - |
DS-KZPCC-BE
|
|
PCI 4-channel Ultra3 (LVD) SCSI RAID controller**,
256-MB cache, (uses one PCI slot); supports 14 disks per channel with
DS-SL13R-xx Ultra3 shelves; requires BN37A-xx cable to connect adapter
to DS-SL13R-xx Ultra3 shelf.
|
8 | 8 | 8 | - | - | - |
DS-KZPCC-DF
|
|
68-pin VHDCI male-to-VHDCI male UltraSCSI cable;
xx=02, 03, 05, 10, 20 meter |
BN37A-xx
|
||||||
|
* NOTE: Tru64 UNIX V5.1 is required to support
54 adapters per partition and 13 adapters per PCI drawer. Tru64 UNIX 4.0G
supports 24 adapters per partition.
|
|||||||
|
** NOTE: Requires a Graphics Adapter or Graphical
Display Station for its configuration utility (other than the base system
console).
|
|||||||
|
NOTES:
Use 2-meter cable to connect adapters, controllers, and shelf within the GS80 cabinet. Use 10-meter cable to connect adapters, controllers to shelves in attached H9A20 expander cabinets. Use 10-to 25-meter cables to connect adapters, controllers to shelves in remote expander cabinets. |
|||||||
| HVD to LVD Converters |
HVD (High Voltage Differential) adapters and LVD (Low Voltage Differential) devices are normally incompatible due to their different signaling voltage levels. This incompatibility does not allow direct communication between the different technologies. The HVD to LVD converter allows connectivity between legacy HVD Host Bus Adapters and today's LVD devices. The converter provides:
|
|
| HVD to LVD one-port converter |
3X-DWZCV-BA
|
|
| HVD to LVD two-port converter |
3X-DWZCV-CA
|
|
|
|
||
| CI Adapters (OpenVMS only) |
PCI CI adapter, maximum 26 per system or hardware partition (12 per drawer, six per PCI drawer); requires two PCI slots |
CIPCA-BA
|
| Computer interconnect cable set, connects CIPCA to star coupler; select length xx=10, 20, 45 meter |
BNCIA-xx
|
|
|
|
||
| Step 7b - Internal Storage | ||
|
|
||
| Ultra3 SCSI (LVD) Storage Devices (for use with DS-SL13R-xx Shelves) | 18.2-GB Ultra3 SCSI 15,000 rpm Universal 1-inch disk drive |
3R-A3848-AA
|
| 36.4-GB Ultra3 SCSI 10,000 rpm Universal 1-inch disk drive |
3R-A3838-AA
|
|
| 36.4-GB Ultra3 SCSI 15,000 rpm Universal 1-inch disk drive |
3R-A3849-AA
|
|
| 72.8-GB Ultra3 SCSI 10,000 rpm Universal 1-inch disk drive |
3R-A3839-AA
|
|
| 72.8-GB Ultra3 SCSI 10,000 rpm Universal 1-inch disk drive |
3R-A3851-AA
|
|
| 146-GB Ultra3 SCSI 10,000 rpm Universal 1-inch disk drive |
3R-A3841-AA
|
|
|
|
||
| Ultra2 SCSI (LVD) Tape Devices (for use with DS-SL13R-xx Shelves) | AIT-351B, 35-GB tape drive embedded in hot-plug Universal carrier |
3R-A2396-AA
|
| AIT-50, 50-GB tape drive embedded in hot-plug Universal carrier |
3R-A2779-AA
|
|
| AIT-100, 2000-GB tape drive embedded in hot-plug Universal carrier |
3R-A3621-AA
|
|
| DAT 40 internal tape drive
kit (Q1553A) |
3R-A4752-AA
|
|
| DAT 72 internal tape drive kit (Q1525A) |
3R-A4544-AA
|
|
|
|
||
| Step 7c - Tape Devices | ||
|
|
||
| 3U Rackmount Tape Drive Enclosure | 3U LVD Rackmount Tape Drive Enclosure for use in H9Axx Series Cabinets, 0 drives, carbon black |
274338-B21
|
| Rackmount kit for H9Axx Series Cabinet, carbon black required for mounting 3U Rackmount Tape Drive Enclosure in H9Axx cabinets |
3R-A3804-AA
|
|
| NOTE: The 3U
Tape Drive Enclosure supports up to four internal half-height removable
devices, or up to two full height devices. Select up to four AIT or DAT
devices, or two DLT/SDLT devices with 3U Rackmount Tape Drive Enclosure (274338-B21), or select preconfigured configurations listed below. |
||
|
|
||
| Tape Drives for
Use in 3U Rackmount Tape Drive Enclosure (Requires 3X-KZPCA-AA or 3X-KZPEA-DB LVD Adapter) |
AIT 35/70-GB 3U internal tape drive, carbon black |
216884-B21
|
| AIT 50/100-GB 3U internal tape drive, carbon black (157766-B22) |
3R-A3753-AA
|
|
| DAT 20/40-GB 3U internal tape drive, carbon black (157769-B22) |
3R-A3752-AA
|
|
| DLT8000 40/80-GB internal tape drive, carbon black |
146196-B22
|
|
| SDLT 110/220-GB internal tape drive, carbon black |
192106-B25
|
|
| SDLT 160/320-GB internal tape drive, carbon black |
257319-B21
|
|
|
|
||
| Preconfigured Configurations | AIT 50-GB, 3U rackmount kit, carbon black |
274333-B21
|
| DLT 40/80-GB, 3U rackmount kit, carbon black |
274332-B21
|
|
| DLT 40/80-GB, dual-drive, 3U rackmount kit, carbon black |
274335-B21
|
|
| SDLT 110/220-GB, single drive, 3U rackmount kit, carbon black |
274331-B21
|
|
| SDLT 110/220-GB, dual-drive, 3U rackmount kit, carbon black |
274334-B21
|
|
|
|
||
| 5U Rackmount Tape Drive Enclosure (Requires 3X-KZPCA-AA or 3X-KZPEA-DB LVD Adapter) | 5U Rackmount Tape Drive Enclosure (Requires 3X-KZPCA-AA or 3X-KZPEA-DB LVD Adapter) |
274339-B21
|
| Rackmount Kit for H9Axx Series Cabinet, carbon black required for mounting 5U Rackmount Tape Drive Enclosure in H9Axx cabinets |
254795-001
|
|
| NOTE: The 5U Rackmount Tape Drive Enclosure supports four full-height devices; select up to four DLT or SDLT devices with 274339-B21, or select preconfigured configurations listed below. | ||
|
|
||
| Tape Drives for Use in 5U Tape Drive Enclosure | DLT8000 40/80-GB tape drive, carbon black |
146196-B22
|
| SDLT 110/220-GB tape drive, carbon black |
192106-B25
|
|
| SDLT 160/320-GB tape drive, carbon black |
257319-B21
|
|
|
|
||
| Preconfigured Configurations | SDLT 110/220-GB Tape Array III, 5U rackmount kit, carbon black |
274336-B21
|
| DLT 40/80-GB Tape Array III, 5U rackmount kit, carbon black |
274337-B21
|
|
| DLT Tape Array III Model 0 enclosure, U.S. |
168047-001
|
|
| Same as above, International |
168047-B31
|
|
| Same as above, Japan |
168047-291
|
|
|
|
||
| AIT Tabletop Tape Drives | AIT 35/70-GB 8-mm LVD tabletop tape drive, North America, carbon black; requires LVD adapter |
216885-001
|
| Same as above, International |
216885-B31
|
|
| Same as above, Japan |
216885-291
|
|
| AIT 50/100-GB 8-mm SCSI tabletop tape drive with 120V North America power cord, carbon black; requires Ultra2 (LVD) adapter |
157767-002
|
|
| Same as above, International |
157767-B32
|
|
| Same as above, Japan |
155767-292
|
|
|
|
||
| AIT Hot-plug Tape Drives | AIT 35/70-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves |
3R-A2396-AA
|
| AIT 50/100-GB hot-plug LVD Universal tape drive, uses two slots in or 43xxx shelves |
3R-A2779-AA
|
|
| AIT-100, 2000-GB tape drive embedded in hot-plug Universal carrier |
3R-A3621-AA
|
|
|
|
||
| AIT Autoloaders | AIT 35-GB tabletop autoloader, 8 cartridge, U.S. |
292355-001
|
| Same as above, International |
292355-B31
|
|
| AIT 35-GB rackmount autoloader, 8 cartridge, U.S. |
280349-001
|
|
| Same as above, International |
280349-B31
|
|
| AIT Rail kit for rackmount autoloader |
284930-001
|
|
|
|
||
| AIT Tape Libraries | SSL2020 AIT tabletop library with one AIT 50-GB drive and 20 slots, LVD |
175195-B21
|
| SSL2020 AIT tabletop library with two AIT 50-GB drives and 20 slots, LVD |
175195-B22
|
|
| SSL2020 AIT rackmount library with one AIT 50-GB drive and 20 slots, LVD |
175196-B21
|
|
| SSL2020 AIT rackmount library with two AIT 50-GB drives and 20 slots, LVD |
175196-B22
|
|
|
|
||
| DAT Tabletop Tape Drives | DAT 12/24-GB 4-mm narrow single-ended tabletop SCSI tape drive with 120V North American power cord; requires BN31W-xx SCSI cable |
DS-TLZ10-DB
|
| DAT 20/40-GB 4-mm Wide Ultra2 (LVD) tabletop SCSI tape drive with 120V North American power cord, carbon black; requires Ultra2 (LVD) adapter |
157770-002
|
|
| Same as above, International |
157770-B32
|
|
| Same as above, Japan |
157770-292
|
|
| DAT 40-GB LVD tabletop tape
drive with North America power cord (Q1554A) |
3R-A4753-AA
|
|
| Same as above, International
(Q1555A) |
3R-A4754-AA
|
|
| DAT 72-GB LVD tabletop tape
drive with North America power cord (Q1525A) |
3R-A4545-AA
|
|
| Same as above, International |
3R-A4546-AA
|
|
|
|
||
| DAT Hot-plug Tape Drive | DAT 40-GB hot-plug LVD tape
drive (Q1546A), uses two slots in 43xxx shelves |
3R-A4745-AA
|
| DAT 72-GB hot-plug LVD tape drive (Q1529A), uses two slots in 43xxx shelves |
3R-A4747-AA
|
|
|
|
||
| DAT Autoloaders | DAT 20/40-GB auto loader external; requires BN31W-xx SCSI cable and 3X-KZPCA-AA, 3X-KZPEA-DB, or 3X-DEPVZ-AA adapter, North America |
166505-001
|
| Same as above, International |
166505-B31
|
|
| Same as above, Japan |
166505-291
|
|
|
|
||
| DLT/SDLT Tabletop
Tape Drives (Requires 3X-KZPCA-AA or 3X-KZPEA-DB LVD Adapter) |
DLT8000 tabletop 40/80-GB DLT external tape drive, carbon black - U.S. |
146197-B23
|
| Same as above Japan |
146197-292
|
|
| SDLT tabletop 110/220-GB external tape drive, carbon black- U.S. |
192103-002
|
|
| Same as above International |
192103-B32
|
|
| Same as above Japan |
192103-292
|
|
| SDLT tabletop 160/320-GB external tape drive, carbon black - U.S. |
257319-001
|
|
| Same as above - International |
257319-B31
|
|
| Same as above - Japan |
257319-291
|
|
|
|
||
| Library Rackmount Kit for MSL5xxx Tape Libraries in H9Axx Cabinet Series | Rackmount kit for H9Axx Series cabinets required for mounting MSL5000 series in H9Axx cabinets |
254795-001
|
|
|
||
| SDLT Tape Libraries | SDLT Tape Libraries require the use of either a 3X-KZPCA-AA or 3X-KZPEA-DB adapter; Tru64 UNIX 5.1B requires a minimum level of PK4 | |
|
|
||
| StorageWorks MSL5026SL SDLT 110/220-GB Tape Library | MSL5026SL, SDLT tabletop library with one 110/220-GB SDLT tape drive, LVD; graphite |
302511-B21
|
| MSL5026SL, SDLT tabletop library with two 110/220-GB SDLT tape drives, LVD; graphite |
302511- |