Overview
|
HP StorageWorks MSL5060 Tape Library |
||
![]() |
||
|
HP StorageWorks MSL5060 Tape Library
|
||
| Introduction |
| The HP StorageWorks MSL5060 Tape Library provides growth opportunities and investment protection for your rapidly growing storage needs. Designed for flexibility, HP's midrange system library (MSL) can be scaled with additional MSL libraries. This feature allows a single library to grow dynamically with capacity and technology needs (up to 16 drives and 240 slots). In addition, the MSL5000 libraries are easily managed through an intuitive GUI control panel and integrated remote Web management. |
|
|
Models
| HP StorageWorks MSL5060 Tape Library Models | NOTE: The HP StorageWorks MSL5060 Tape Library comes with 60 media slots (including two mail slots) and can be configured with up to four HP StorageWorks LTO Ultrium 230 Tape Drives (number of drives determined by SKU chosen). | |
| MSL5060, 0 DRV, Ultrium 230, RM Library |
301899-B21
|
|
| MSL5060, 2 DRV, Ultrium 230, TT Library |
301900-B21
|
|
| MSL5060, 2 DRV, Ultrium 230, RM Library |
301899-B22
|
|
| MSL5060, 2 DRV, Ultrium 230, embedded
Fibre, RM Library |
301899-B23
|
|
| MSL5000 LTO Ultrium 230 upgrade
drive in hot plug canister |
301901-B21
|
|
| MSL Ultrium 460 upgrade drive in hot plug canister |
330729-B21
|
|
| NOTE: The MSL Ultrium 460 upgrade drives in hot plug canister (330729-B21) are intended to be used to field upgrade MSL5060 libraries to Ultrium 460. If this is a new installation, and Ultrium 460 is desired, please purchase an MSL6060. | ||
| MSL5000 Universal Pass-through Mechanism |
304825-B21
|
|
| MSL5000 10U Pass-through extender |
231824-B23
|
|
| NOTE: Each library
installation will require, (1) library system, (1) geographically specific
power cord, (1) SCSI cable for each LTO Ultrium 230 drive pair, and LTO
Ultrium media with bar code labels for each MSL5060. Multiple configurations
will require additional Pass-through kits. |
||
| NOTE: The minimum
orderable configuration consists of a single library system (for instances
where customer already has the necessary SCSI cables, power cord, and media). |
||
| NOTE: For a 4-drive configuration, the 2-drive base model and 2 additional upgrade drives must be ordered. | ||
|
NOTE: Installation services may also be ordered for customers who want to have a certified Hewlett-Packard engineer perform an onsite library installation. |
|
|
Standard Features
| MSL5060 Library Customer Benefits |
|
|
|
|
||
| Key Features |
|
|
|
|
Product Highlights
| Multi-unit Modular Scalability | The MSL5060 has the capability for multi-unit scalability; up to four libraries can be scaled together in a virtual library. The first module houses the MSL5000 pass-through mechanism, which has the elevator mechanism for tape movement. Each additional module requires the MSL5000 10U pass-through extender. | ||
|
| |||
| High Availability and Hot Pluggable Drives | As data becomes more
mission critical, and downtime becomes more costly, customers are requiring
high availability features on tape automation devices. The MSL5060 supports
(standard) dual redundant power supplies as well as hot pluggable drive
carriers, allowing drive replacement without interrupting backup and restore
functions. These hot pluggable drive carriers allow for easy scalability
of performance, as well as provide an easy upgrade path towards future Ultrium
drive technologies. NOTE: The MSL5060 accepts only library ready drives specifically modified for use in the MSL library family of products. |
||
|
|
|||
| Investment Protection |
The MSL5060 can be upgraded to Ultrium 460 tape drives in 3 easy steps:
When doing this, the library MUST be configured with one (1) drive per SCSI bus. Ultrium 460 drives can read and write Ultrium 1 media providing backward compatibility. |
||
|
| |||
| Manageability | The MSL5060 library configurations are fully supported through Insight Manager 7.0, providing information to administrators for robotic status, tape status changes and fault status. HP TSMC (tape storage management console) and HP Library and Tape Tools (LTT) provide diagnostics and easy firmware upgrade capabilities. | ||
| | |||
| Proven Reliability | Using LTO Ultrium 230 tape drives, and proven library robotics with a rating of 2,000,000 robot load/unload cycles, the MSL5060 provides the necessary high reliability for today's demanding environment. | ||
|
|
|||
| LTO Ultrium Technology | LTO Ultrium tape drives use best of breed technology. By taking the best features from other tape technologies and combining them into a single new technology Ultrium tape drives are in a league of their own. Inclusion of innovative features such as Adaptive Tape Speed (ATS) ensure that Ultrium drives can meet the performance and reliability demands of a library environment, whether it is direct attach SCSI (DAS) or a Storage Area Network (SAN). Linear Tape Open (LTO) technology is an industry open-standard format; thus data written on HP StorageWorks Ultrium tape drives can be interchanged directly with other Ultrium tape drives from other vendors. | ||
|
|
|||
| Remote Management Interface | Web-based management is included to allow monitoring and managing the library from across the room or across the globe. Many of the functions that are available on the front panel are included in the remote management interface. These include, but are not limited to, library and drive status, moving media, load/unload tape drives, access to diagnostics, library configuration, library statistics, inventory check, and security settings. | ||
|
|
|||
| HP StorageWorks Library and Tape Tools (L&TT) | The MSL5060 Tape Library configurations are supported on HP's industry-leading diagnostic tool - HP StorageWorks Library and Tape Tools (L&TT). L&TT is a single, convenient program that's a snap to install and simple to operate. L&TT's intuitive user interface eliminates the need for training and deploys in less than five minutes. This robust diagnostic tool is designed for both the experienced professional and the untrained administrator. It ensures product integrity through self-diagnostics and fast resolution to device concerns. Additional information on L&TT plus download information can be found at: http://www.hp.com/support/tapetools. | ||
|
|
|||
| Compatibility | |
| Server Support |
The HP StorageWorks MSL5060 Library family are supported on the following classes of HP systems:
NOTE: For details of which models work with which systems, including third-party systems, visit http://www.hp.com/go/ebs for the latest hardware compatibility information. |
|
|
|
| Application Support |
Automation and Network Utilities:
|
|
| |
| ISV/OS Support | For the most up-to-date ISV & OS support please consult the Enterprise Backup Solutions Compatibility Matrix at http://www.hp.com/go/ebs. |
|
| |
| Media Partitioning Support |
Media partitioning is the capability to create logical pools or partitions in a tape library. The MSL tape libraries media partitioning capability supports multiple drives types within a single library or in a multi-unit stack. For current software supported, please consult the Enterprise Backup Solutions Compatibility Matrix at http://www.hp.com/go/ebs. | ||
|
|
Service and Support, HP Care Pack and Warranty Information
| Warranty | One year, limited warranty, together
with phone support for the duration of the warranty. In order to provide ease of installation, maximize uptime and ROI, Hewlett Packard provides a range of upgradeable service options. |
|
|
|
| Warranty Upgrade Options |
|
|
|
|
| HP Care Pack Information |
HP Care Pack is defined as an upgrade to the product warranty attribute,
available for a specific duration and hours of coverage
For additional HP Care Pack (hardware & software) information, as
well as orderable part numbers, please refer to the URL listed below: |
|
|
|
| Software Product Services |
|
|
|
|
| Hardware Product Services |
For additional hardware installation and maintenance information please
refer to the URLs listed below: |
|
|
|
| Support Services |
HP Services provides a three-year, limited warranty, fully supported
by a worldwide network of resellers and service providers and 9x5 hardware
technical phone support during the warranty period. In addition, available
service offerings include a full range of optional packaged hardware and
software services:
|
|
|
|
| Components | The following brick level options/components do not have individual HP Care Pack Services. These items will be included in product HP Care Pack Services into which they are installed. | ||||
| Disk Drives | Tape Drives | CD/DVD ROM | SCSI Hubs in SBBs | Adapters | |
| Bus Converters | Backplane RAID Controllers | Power Supplies | Cabling | Fans | |
|
|
Kit Contents
| Description |
Part Number
|
|
| MSL5060 Library System | MSL5060, 0 DRV, RM Library |
301899-B21
|
| MSL5060, 2 DRV, LTO Ultrium 230, RM Library |
301899-B22
|
|
| MSL5060, 2 DRV, Ultrium 230, embedded Fibre, RM Library |
301899-B23
|
|
| MSL5060, 2 DRV, LTO Ultrium 230, TT Library |
301900-B24
|
| Supplied with each Library Unit | ||
| Library Unit (pre-configured
with drives, fibre card as applicable) |
||
| Documentation Kit |
||
| EFIJS Translation CD |
||
| Users Guide |
||
| Diagnostic diskette/Software Guide
|
||
| One HP LTO Ultrium 100GB (native)
Data Cartridge |
||
| One HP Ultrium Universal Cleaning
Cartridge |
||
| Bar Code Labels (35 Labels) |
||
| SCSI Terminator(s) (1 per drive)
|
||
| SCSI Jumper Cable(s) VHDCI .5m
(1 per drive) |
||
| Diagnostic Cable (RJ11-DB9 for
PC attach) |
||
| MSL5000 & 6000 Series Documentation
CD |
||
| Driver CD - Media Robot utility
CD |
||
| MSL Utility floppy diskettes (2
disks) |
||
| Warranty Card |
||
| Safety Warnings Document | ||
| ISS Safety Guide-HP |
||
| 5U/10U Rack Template Poster (RM only) |
|
|
Related Options
| Upgrade Accessories | MSL5000 LTO Ultrium 230 upgrade
drive in hot plug canister |
301901-B21
|
| MSL Ultrium 460 upgrade drive
in hot plug canister NOTE: One drive per SCSI bus. |
330729-B21
|
|
| MSL5000 Universal Pass-through
Mechanism |
304825-B21
|
|
| MSL5000 10U Pass-through extender |
231824-B23
|
|
| Power Cord | Power Cord, US/canada/Mexico NOTE: Shipped with all units. |
227099-001
|
| NOTE: US/canada/Mexico power cords are shipped with all models. Order geographically specific power cords as needed. (Unit requires 2 power cords - one for each power supply.) |
|
| Media | MSL5000 dual LTO magazine (2x15 slot magazine left and right) |
301902-B21
|
| HP LTO Ultrium data cartridge |
C7971A
|
|
| HP LTO Ultrium universal cleaning
cartridge |
C7978A
|
|
| HP Ultrium bar code labels, 100 pack |
C7970B
|
|
| SCSI Cables | SCSI Cable, VHDCI, 6 feet |
341174-B21
|
| SCSI Cable, VHDCI/VHDCI, 12 feet |
341175-B21
|
|
| SCSI Cable, VHDCI/Wide, 6 feet |
341176-B21
|
|
| SCSI Cable, VHDCI/Wide, 12 feet |
341177-B21
|
|
| SCSI Cable, VHDCI/Wide, 10 meter |
201160-B21
|
|
| NOTE:
Check the cable-adapter matrix for tape libraries on: ftp://ftp.compaq.com/pub/products/storageworks/tape-and-optical-storage/adapter-cable-matrix.pdf |
|
|
| FC Host Bus Adapters | For more information on FC HBAs, please consult the EBS connectivity matrix at http://www.hp.com/go/ebs |
|
| SCSI Host Bus Adapters | For more information on FC HBAs, please consult the EBS connectivity matrix at http://www.hp.com/go/ebs |
|
| Interface Cards | Network Storage Router E1200 -
160 MSL embedded fibre option kit graphite |
330728-B21
|
|
| Rack mounting Kits | MSL5000 system/e bracket Kit (HP racks) |
304826-B21
|
| MSL5026 TT-RM KIT, ProLiant Rack |
231894-B22
|
|
| MSL5026 TT-RM KIT, Alpha/HP Rack |
231894-B21
|
|
| Alpha Rail Kit |
254795-001
|
|
|
|
||
| Pass-through Mechanism | MSL5000, universal Pass-through
mechanism NOTE: Includes elevator mechanism and router, required to connect first two units in a stack) (capable of handling both SDLT and LTO media. |
304825-B21
|
| MSL5000, 10U Pass-through extender |
231824-B23
|
|
| HP Care Packs | NOTE: HP also offers 1-year options for the services quoted below. | |
| Initial Tape Library Installation NOTE: Band for MSL5060 Library: 463. Installation Band: 5DR. |
HA113A1
|
|
| Initial
Tape Library Implementation Into SAN NOTE: Band for MSL5060 Library: 463. Installation Band: 5DR. NOTE: Due to the complexities involved with the initial installation of an enterprise Library into a SAN environment, HP recommends that customers take advantage of the SAN Implementation Service (HA114A1). This service covers pre-installation preparation activities, installation and configuration of the library and router, configuration of hosts and switches, verification testing and customer orientation. |
HA114A1
|
|
| Subsequent
Tape Installation NOTE: Band for drive upgrade kits: 8G5. Installation Band: 5DU. |
HA113A1
|
|
| Hardware,
3-year, next-day, on-site NOTE: Band for MSL5060 Library: 463. Band for drive upgrade kits: 8G5. |
HA101A3
|
|
| Hardware,
3-year, 4-hour, 13 x 5, on-site NOTE: Band for MSL5060 Library: 463. Band for drive upgrade kits: 8G5. |
HA103A3
|
|
| Hardware,
3-year, 4-hour, 24 x 7, on-site NOTE: Band for MSL5060 Library: 463. Band for drive upgrade kits: 8G5. |
HA104A3
|
|
| Hardware
Support plus, 3-year NOTE: Band for MSL5060 Library: 463. Band for drive upgrade kits: 8G5. NOTE: Support Plus covers Hardware support only. |
HA109A3
|
|
| Hardware
Support plus 24, 3-year NOTE: Band for MSL5060 Library: 463. Band for drive upgrade kits: 8G5. NOTE: Support Plus covers Hardware support only. |
HA110A3
|
|
| Auto-Power-On NOTE: Band for Auto-Power-On: 5AU. NOTE: Auto-power-on is a feature that allows the library to reboot in the event of a power failure without operator intervention. This feature must be installed by an authorized service technician. |
HA124A1
|
|
| NOTE: In order
to maximize ROI and product uptime, and minimize the cost of ownership,
HP recommends the 3-year, 24 x 7 service options. These offerings will ensure
that any product issue can be tackled when they occur (most back up issues
will occur outside standard business hours) and that the service coverage
regarding period, covers the minimum expected life of the host system. NOTE: Check the cable-adapter matrix for tape libraries on: ftp://ftp.compaq.com/pub/products/storageworks/tape-and-optical-storage/adapter-cable-matrix.pdf |
|
| HP OpenView Storage Data Protector Software | Starter Packs |
|
| Cell Manager NOTE: Required once as starter pack; includes license-to-use, unlimited number of disk agents and media agents, one drive extension, libraries with up to 60 slots, CD-ROM media, manuals, and more; for Windows NT, 2000, XP. |
B6961AA
|
|
| Cell Manager NOTE: Required once as starter pack; includes license-to-use, unlimited number of disk agents and media agents, one drive extension, libraries with up to 60 slots, CD-ROM media, manuals, and more; for HP-UX. |
B6951AA
|
|
| Drive Extensions |
||
| Drive License NOTE: License-to-use for one concurrently used backup drive in locally attached environment; for Windows NT, 2000, XP/Novell NetWare/Linux. |
B963AA | |
| Drive
License NOTE: License-to-use for one concurrently used backup drive; for locally attached UNIX®, NAS or SAN |
B6953AA
|
|
| License-to-use for one concurrently used backup drive; for UNIX®, NAS, SAN | ||
| For the most up-to-date information, visit: http://www.hp.com/go/dataprotector |
|
|
Configuration Information
| (for rack-mount units only) | |
| Step 1 Select a Configuration | |
| NOTE: The list below is not intended to show all possible configurations, but to show some of the most common. In some cases, it is advantageous to utilize MSL5030 and MSL5060 libraries in the scaled stack. Please refer to the MSL5030 library QuickSpecs for more details. The Ultrium MSL5000 series of libraries is scalable to 40U resulting in 16 drives and 240 slots. | |
| IMPORTANT NOTE: Each library unit comes with a rack kit specially designed for HP 9000 & 10000 racks. If the unit is going to be installed into a HP Surestore System\E rack or an Alpha rack, then 1 rack mount kit per library unit must be purchased. Please utilize "STEP 2" of the configuration information. | |
|
|
| Common Scaled Configurations for MSL5000 Libraries |
| Direct Attach SCSI |
| Slots | Drives | Interface | Qty | Description |
Product Number |
| 60 | 2 | SCSI | 1 | MSL5060L1 2-drive RM | 301899-B22 |
| 2 | Rack kits | See step 2 for details | |||
| 60 | 3 | SCSI | 1 | MSL5060L1
2-drive RM | 301899-B22 |
| 1 | MSL5000 Ultrium 230 add-on drives | 301901-B21 | |||
| 1 | Rack kits | See step 2 for details | |||
| 60 | 4 | SCSI | 1 | MSL5060L1 2-drive RM | 301899-B22 |
| 2 | MSL5000 Ultrium 230 add-on drives | 301901-B21 | |||
| 1 | Rack kits | See step 2 for details | |||
| 90 | 2 | SCSI | 1 | MSL5030L1 2-drive RM | 301897-B23 |
| 1 | MSL5060L1 0-drive RM | 301899-B21 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 5U pass-thru extender kit | 231824-B22 | |||
| 2 | Rack kits | See step 2 for details | |||
| 90 | 3 | SCSI | 1 | MSL5030L1 1-drive RM | 301897-B22 |
| 1 | MSL5060L1 2-drive RM | 301899-B22 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 5U pass-thru extender kit | 231824-B22 | |||
| 2 | Rack kits | See step 2 for details | |||
| 90 | 4 | SCSI | 1 | MSL5030L1 2-drive RM | 301897-B23 |
| 1 | MSL5060L1 2-drive RM | 301899-B22 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 5U pass-thru extender kit | 231824-B22 | ||||
| 2 | Rack kits | See step 2 for details | |||
| 90 | 6 | SCSI | 1 | MSL5030L1 2-drive RM | 301897-B23 |
| 1 | MSL5060L1 2-drive RM | 301899-B22 | |||
| 2 | MSL5000 Ultrium 230 add-on drives | 301901-B21 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 5U pass-thru extender kit | 231824-B22 | |||
| 2 | Rack kits | See step 2 for details | |||
| 120 | 4 | SCSI | 2 | MSL5060L1
2-drive RM | 301899-B22 |
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 10U pass-thru extender kit | 231824-B22 | |||
| 2 | Rack kits | See step 2 for details | |||
| 120 | 3 | SCSI | 2 | MSL5060L1 2-drive RM | 301899-B22 |
| 2 | MSL5000 Ultrium 230 add-on drives | 301901-B21 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 10U pass-thru extender kit | 231824-B22 | |||
| 2 | Rack kits | See step 2 for details | |||
| 120 | 8 | SCSI | 2 | MSL5060L1 2-drive RM | 301899-B22 |
| 4 | MSL5000 Ultrium 230 add-on drives | 301901-B21 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 10U pass-thru extender kit | 231824-B22 | |||
| 2 | Rack kits | See step 2 for details | |||
| Common Scaled Configurations for MSL5000 Libraries |
| SAN or Direct Attach Fibre |
| Slots | Drives | Interface | Qty | Description |
Product Number |
| 60 | 2 | Fibre Channel | 1 | MSL5060L1FC 2-drive RM | 301899-B23 |
| 1 | Rack kits | See step 2 for details | |||
| 60 | 3 | Fibre Channel | 1 | MSL5060L1FC 2-drive RM | 301899-B23 |
| 1 | MSL5000 Ultrium 230 add-on drives | 301901-B21 | |||
| 1 | Rack kits | See step 2 for details | |||
| 60 | 4 | Fibre Channel | 1 | MSL5060L1FC 2-drive RM | 301899-B23 |
| 2 | MSL5000 Ultrium 230 add-on drives | 301901-B21 | |||
| 1 | Rack kits | See step 2 for details | |||
| 90 | 2 | Fibre Channel | 1 | MSL5030L1FC 2-drive RM | 301897-B25 |
| 1 | MSL5060L1 0-drive RM | 301899-B21 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 5U pass-thru extender kit | 231824-B22 | |||
| 2 | Rack kits | See step 2 for details | |||
| 90 | 3 | Fibre Channel | 1 | MSL5060L1FC 2-drive RM | 301899-B23 |
| 1 | MSL5030L1FC 1-drive RM | 301897-B24 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 5U pass-thru extender kit | 231824-B22 | |||
| 2 | Rack kits | See step 2 for details | |||
| 90 | 4 | Fibre Channel | 1 | MSL5060L1FC 2-drive RM | 301899-B23 |
| 1 | MSL5030L1FC 2-drive RM | 301897-B25 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 5U pass-thru extender kit | 231824-B22 | |||
| 2 | Rack kits | See step 2 for details | |||
| 90 | 6 | Fibre Channel | 1 | MSL5060L1FC 2-drive RM | 301899-B23 |
| 1 | MSL5030L1FC 2-drive RM | 301897-B25 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 5U pass-thru extender kit | 231824-B22 | |||
| 2 | Rack kits | See step 2 for details | |||
| 120 | 4 | Fibre Channel | 2 | MSL5060L1FC 2-drive RM | 301899-B23 |
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 10U pass-thru extender kit | 231824-B23 | |||
| 2 | Rack kits | See step 2 for details | |||
| 120 | 6 | Fibre Channel | 2 | MSL5060L1FC 2-drive RM | 301899-B23 |
| 2 | MSL5000 Ultrium 230 add-on drives | 301901-B21 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 10U pass-thru extender kit | 231824-B23 | |||
| 2 | Rack kits | See step 2 for details | |||
| 120 | 8 | Fibre Channel | 2 | MSL5060L1FC 2-drive RM | 301899-B23 |
| 4 | MSL5000 Ultrium 230 add-on drives | 301901-B21 | |||
| 1 | Universal pass-thru mechanism | 304825-B21 | |||
| 1 | 10U pass-thru extender kit | 231824-B23 | |||
| 2 | Rack kits | See step 2 for details | |||
| Step 2 Select the Appropriate Rack | ||
| Depending on the environment, different rack kits are required. Each rack-mounted version of MSL5000 libraries includes a rack kit designed for Compaq 9000, HP 10000 and millennium racks. If installing into these racks no additional kits are needed. If the environment is different, one of the following kits is necessary (one for each library in a stack) | ||
|
Part Number
|
||
| Rack-mounting Kits | MSL5000 system/e RM kit (HP racks) |
304826-B21
|
| Alpha Rail Kit |
254795-001
|
|
|
|
Technical Specifications
| Dimensions | Form Factor | 10U Rack-mount Table Top | ||
| Physical (HxWxD) 0 Drive, RM | 17.50 x 17.00 x 30.00 in (44.50 x 43.20 x 76.20 cm) | |||
| Physical (HxWxD) 2 Drive, RM | 17.50 x 17.00 x 31.50 in (44.50 x 43.20 x 80.00 cm) | |||
| Physical (HxWxD) 2 Drive, TT | 18.50 x 19.00 x 31.50 in (47.00 x 48.30 x 80.00 cm) | |||
| Shipping (HxWxD) 0, 2 Drive, RM | 33.00 x 47.00 x 31.00 in (83.80 x 119.40 x 78.7 cm) | |||
| Shipping (HxWxD) 2 Drive, TT | 33.00 x 47.00 x 31.00 in (83.80 x 119.40 x 78.7 cm) | |||
| Weight | Out of box, 0 Drive, RM |
95.0 lb (43.1 kg) | ||
| Out of box, 2 Drive, RM |
109.0 lb (49.4 kg) | |||
| Out of box, 2 Drive, TT |
122.0 lb (55.3 kg) | |||
| Shipping, 0 Drive, RM |
147.0 lb (66.7 kg) | |||
| Shipping, 2 Drive, RM |
161.0 lb (73.0 kg) | |||
| Shipping, 2 Drive, TT | 174.0 lb (78.9 kg) | |||
| Control Panel | Library and Drive Status | |||
| Move tape cartridges | ||||
| Load/Unload tape drives | ||||
| Maintenance (diagnostics) | ||||
| Library Configuration | ||||
| Statistics | ||||
| Inventory Check | ||||
| Security level set: operator, user, service | ||||
| Mail slot access | ||||
| Offline/Online Status | ||||
| Magazine removal/replacement | ||||
| SCSI Interface | Ultra2 LVD SCSI, VHDCI interconnect | |||
| Capacity (native) | 6.0 TB | |||
| Performance (native) | Adaptive Tape Speed |
15 MB/s per drive | ||
| Base Unit | Supports up to 4 LTO Ultrium 230 drives for native transfer rates up to 216 GB/hour | |||
| Maximum configuration | Supports up to 16 LTO Ultrium 230 drives for native transfer rates up to 864 GB/hour (four modules with multi-unit scalability) | |||
| Storage Capacity (compressed @ 2:1) | Per Cartridge | 200GB per cartridge | ||
| Base Unit | 60 slots (including two mail slots), for capacity of 12.0 TB (2:1 compressed) | |||
| Maximum configuration | 240 slots, for capacity up to 48TB (2:1 compressed) (four modules with multi-unit scalability) | |||
| Power Consumption | MSL5060 base unit | 90 to 132V AC @ 47
to 63Hz 180 to 264V AC @ 47 to 63Hz |
||
| Power Requirement (typical) |
300 Watts |
|||
| Power Requirement (maximum) |
360 Watts |
|||
| Heat Dissipation (typical) |
1020 BTU's/hour |
|||
| Heat Dissipation (maximum) | 1224 BTU's/hour | |||
| Acoustic Noise | Noise Power Emission Level | 8 bels, maximum | ||
| Average sound pressure level | 52 dBA | |||
| Robotics Performance | Initialization time | 240 sec | |||
| Inventory time | 110 sec | ||||
| Cartridge swap (drive to slot) |
22 sec average | ||||
| Reliability | MTBF | 250,000 hours (100% duty cycle) (excludes drives) | |||
| MSBF | 2,000,000 robot load/unload cycles | ||||
| Temperature range | Operating | 50° to 95° F (10° to 35° C) | |||
| Storage | -40° to 140° F (-40° to 60° C) | ||||
| Humidity (wet bulb) | Operating | 10 to 80% @ 82° F (28° C) | |||
| Storage | 10 to 90% @ 82° F (28° C) | ||||
| Product Safety Requirements and Approvals | Safety EN60950/IEC950,
UL, CSA/cUL, CE, VDE/TUV, GOST, BSMI EMI, Class A FCC, C.I.S.P.R., ICES-003, CE, VCCI |
||||
|
|
|||||
|
© Copyright 2002-2004 Hewlett-Packard Development Company, L.P.
Windows NT is a US registered trademark of Microsoft Corporation. Unix is a registered trademark of The Open Group. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |