contents
 Overview      Standard Features      Systems      Options      Upgrades      TechSpecs line.gif (50 bytes)

Overview

HP AlphaServer ES47 Tower
HP AlphaStation ES47 Tower
 
1.
I/O Slots
4.
Hard Disk Drive Bays
2.
CPU Building Block Module
5.
CD-RW Drive
3.
Hot-swap Power Supplies
6.
Operator Control Panel

 
At A Glance
AlphaServer/AlphaStation ES47 Tower systems
  • Two 1000-MHz Alpha 21364 processors
  • Advanced on-chip memory controllers and switch logic capable of providing 10.7-GB/s of peak memory bandwidth per processor
  • Choice of memory options; up to 4-GB of RDRAM memory per processor (16-GB total)
  • Redundant features providing maximum uptime - N+1 Voltage regulator Modules (VRMs); hot-plug redundant power supplies; cooling provided by four hot-plug redundant system fans
  • Optional RAID memory support
  • Five PCI-X I/O slots
    - One 64-bit/133-MHz slot
    - Four 64-bit/66-MHz slots
  • One AGP slot
  • Internal hot-plug disk drive storage of 292 GB with two 146-GB SCSI disk drives
  • Integrated Ultra3 SCSI
  • CD-RW Drive
  • Dual USB port
  • Enhanced reliability with ECC-protected memory, processor cache and system data paths
  • Tru64 UNIX or OpenVMS factory installed software (FIS); optional high availability support with Tru64 UNIX and OpenVMS cluster solutions
  • Product warranty, 1-year hardware, on-site next business day and 90-day software, telephone support delivered by
    HP Services
  • Consult the HP Customer Support Center at 1-800 345 1518 for details
contents
 Overview      Standard Features      Systems      Options      Upgrades      TechSpecs line.gif (50 bytes)

Standard Features

Processor Two Alpha 21364 1000-MHz CPUs

Cache Memory 1.75-MB ECC L2 on-chip cache per CPU

Architecture

Low-latency, interprocessor (IP) network with on-chip RDRAM memory controllers and on-chip L2 cache


CPUs, Memory, and I/O slots CPUs supported 2
Memory supported Up to 16 GB
  PCI-X slots supported 5
  AGP slots supported 1

Storage Controller Integrated Ultra3 SCSI adapter for internal disk drives

Interfaces USB One Dual USB port
Server Mgt One MBM Server Management LAN Connection
Serial One MBM serial connection

Form Factor Tower

Boot/Diagnostic Devices CD-R Slim line multi-bay 16X/10X/24X CD-RW
Hard Drives Choice of 18.2/36.4/72.8/146-GB SCSI disk drives

Internal Disk Expansion Total Internal Drive Bays 2

Power Supplies Two @208V (700–Watt @120V) 48V auto-sensing power supplies, hot swappable, N+1
(220v operation only)

OS Support AlphaServer ES47Tru64 UNIX Tower systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server
  AlphaServer ES47 OpenVMS Tower systems include pre-installed software, Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS.
  Minimum OS support - Tru64 UNIX V5.1B + IPK or OpenVMS V7.3-1 + VMS731-EV7_V0100
upgrade kit
  AlphaStation ES47 Tru64 UNIX Tower systems include pre-installed software, 2-user Base license
  AlphaStation ES47 OpenVMS Tower systems include pre-installed software (V7.3-1), Base license, Concurrent Use 1-user license, and NAS 150 Client license

Service and Support Protected by HP Services including a 1-year on-site hardware warranty Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support.
NOTE: For the complete list of supported options, refer to the following Web page:
http://h18002.www1.hp.com/alphaserver/options/ases47/ases47_options.html
contents
 Overview      Standard Features      Systems      Options      Upgrades      TechSpecs line.gif (50 bytes)

Systems

Step 1 - Assess Application Requirements

  • Selection of system components must be made in the context of total application requirements. Although the configuration of system components must be done in steps (for example, base system, memories, disks, etc.), these steps should not be done in isolation.
  • The order in which requirements are assessed is also important, since one requirement may impact others. Before proceeding, it would be useful to assess the total application requirements in the following order:
  • What level of availability is required?
    • If no single points of failure are allowed, then the solution should be configured as a multi-system cluster.
    • If access to specific devices must be assured, consider redundant adapters, RAID memory, etc.
  • What overall capacities are required in terms of performance, memory capacity, and disk storage?
  • How should the system be configured to optimize performance?
    • Memory should be configured according to application guidelines listed in Step 4.
  • What are the near-term system expansion needs?
NOTE: Most configuration steps require that the above data be considered in whole or in part. Be sure to execute each step in the context of the total application requirements.

System Ordering Requirements:

Certain system components or services are either required for normal operation or are recommended for best system performance and/or operation. This document uses the following definitions to specify these options:

  • Mandatory purchase: The system cannot function without this option or service - the option or service must be ordered with the system.
  • Required to function: This option or service is needed to support a working system - the option or service must be ordered with the system or be available onsite.
  • Recommended: System performance or function will be enhanced if this option or service is ordered.
 
AlphaServer/AlphaStation ES47 Tower systems require selection of the following items:

Mandatory Purchases:

  • One Base system (see Step 2)
  • One CPU Building Block Module (see Step 3)
  • One memory option (see Step 4)
  • One system disk drive (see Step 5)
  • Two country-specific power cords (See Step 6)
  • Ethernet adapter (see Step 8)
 
NOTE: AlphaStation ES47 systems require a graphics adapter (see Step 9)

Optional Purchases:

  • Software media and documentation only required for first system onsite
  • Country-specific keyboard and mouse only if required (see Step 10)

Recommended Services:

  • HP Care Pack Service Package

System Management Hardware/Software Requirements

NOTE: The following Server Management requirements only apply to customers who prefer to use the AMS or AMU Server Management software.

  • The AlphaServer Management Station (AMS) provides the highest level of server management for a single or multi platform environment. The AMS provides for a local or remote Web accessible central point of management and control for a multiple ES47/ES80/GS1280 environment.
  • The AlphaServer Management Station software requires the following hardware in order to operate:
    - Tru64 UNIX platform with 1-GB memory, 1-GB disk space, and two network interface cards running Tru64 UNIX V5.1B
    - Wintel platform running Linux, 500-MHz CPU or faster, 1-GB memory, 10-GB disk space
  • The AlphaServer Management Utility (AMU) provides the next highest level of server management. The AMU is a GUI based application that provides a sophisticated, yet user-friendly graphics interface to monitor and manage a single ES47/ES80/GS1280 system. From this application, the user can monitor the status of the platform, and provide a significant level of control of the platform. The AMU is a Web based utility, which allows a user local and remote access from a browser.
  • The AlphaServer Management Utility requires one of the following hardware platforms in order to operate:
    - Wintel platform running Windows 2000, 500-MHz CPU or faster, 1-GB memory, 10-GB disk space
    - Wintel platform running Linux, 500-MHz CPU or faster, 1-GB memory, 10-GB disk space
    - Tru64 UNIX platform running V5.1B or later, 1-GB memory, 10-GB disk space
  • Both the AMS and AMU Software require Internet Explorer 5 or later or Netscape 6.
  • Downloadable AMS/AMU kits and instructions available at: http://ftp.digital.com/pub/Digital/Alpha/firmware/interim/ams/index.html


Step 2 - Select Base System

  • Mandatory selection of at least one Base System required
 

NOTE: Base systems do not include CPUs or memory (see Steps 3 and 4)

 

AlphaServer ES47 Tower Base Systems
Model OS CPUs Supported
(See Step 3)
I/O Slots Order No.
Tower Tru64 UNIX 2 5 PCI/PCI-X, 1 AGP DA-20AAA-AB
Tower OpenVMS 2 5 PCI/PCI-X, 1 AGP DY-20AAA-AB
AlphaStation ES47 Tower Base Systems
   
Tower Tru64 UNIX 2 5 PCI/PCI-X, 1 AGP DA-20AAA-AC
Tower OpenVMS 2 5 PCI/PCI-X, 1 AGP DY-20AAA-AC


Step 3 - CPU Building Block Modules - Mandatory

 
  • Mandatory selection of one CPU Building Block Module or one Capacity on Demand (CoD) CPU Building Block Module required per AlphaServer ES47 Tower System
  • CPU Building Block Module includes two 1000-MHz Alpha 21364 CPUs
  • Selection of CPU Building Block Module type (Tru64 UNIX or OpenVMS) must match base system operating system selected in Step 2
 

CPU Building Block Modules

AlphaServer ES47 Dual CPU Building Block Module, 2xEV7 CPUs, 1000 MHz, Tru64 UNIX SMP License
3X-KN73A-BB
AlphaServer ES47 Dual CPU Building Block Module, 2xEV7 CPUs, 1000 MHz, OpenVMS SMP License
3X-KN73A-BC

Capacity on Demand (CoD) CPU Building Block Modules

AlphaServer ES47 Tower Systems can be configured with CoD CPUs. Capacity on Demand CPUs for the ES47 Tower are licensed to allow activation of one CPU at installation and the activation of the second CPU within 18 months. Memory is NOT included with CoD CPUs but must be ordered (see Step 4).
NOTE: Each CoD CPU must be populated with at least one memory option.
One CPU on the CoD CPU Building Block must remain active, and the active CPU must be the one connected to the internal I/O.

 
AlphaServer ES47 Tower CoD Dual CPU Building Block Module, one CoD CPU and one active CPU, 1000 MHz, Tru64 UNIX SMP License
3X-KN73A-DB
AlphaServer ES47 Tower CoD Dual CPU Building Block Module, 1000 MHz, one CoD CPU and one active CPU, OpenVMS SMP License
3X-KN73A-DC
contents
 Overview      Standard Features      Systems      Options      Upgrades      TechSpecs line.gif (50 bytes)

Options

Step 4 - Memory - Mandatory

Memory Configuration Guidelines  

Memory options should be selected in the context of the application's sensitivity to memory bandwidth and future memory capacity expansion. This will determine the number of memory options to order. The total capacity required will determine the size of the options to be ordered.

  • Mandatory selection of at least one memory option required per ES47 tower system. If CoD CPU is selected in Step 3, two memory options are required.
  • Each ES47 tower system supports up to four memory options (four RIMMs each) and up to four memory RAID options
    (one RIMM each) for a total of 20 RIMMs.
  • Each CPU has two memory controllers.
    • Each memory controller can support four RIMMs (one memory option) and a fifth RIMM slot for redundancy (RAID option).
    • If populated, the two memory controllers per CPU must contain the same size RIMMs.
  • Order one RAID option (one RIMM) per memory option if desired.
  • If RAID memory option is selected, the number of RAID options selected must equal the number of memory options selected.

The following examples illustrate different ways of configuring an ES47 Tower system with a total of 2 GB of memory


    ES47 Tower System
Case Memory Option CPU 1 CPU 2
Controller 1 Controller 2 Controller 1 Controller 2
A 3X-MS7AB-AA (4x128MB) 1 1 1 1
B 3X-MS7AB-BA (4x256MB) 1 - 1 -
C 3X-MS7AB-CA (4x512MB) 1 - - -

Memory Application Examples

 

Configuring memory is a compromise between cost, total memory capacity, and memory bandwidth requirements. The behavior of the application must be used to define the most-desired configuration. Some applications are sensitive to memory capacity while some are sensitive to memory bandwidth. If actual application measurements are not available, the following may be used as guidelines:

  • Large memory (VLM) applications, in which large amounts of memory can substantially reduce I/O throughput, may be optimized for total memory capacity and future capacity growth. In VLM applications, the right balance might be one memory option per CPU. (Case B)
  • Typical commercial applications, such as transaction processing (OLTP) and multi-user timesharing, usually operate efficiently from cache and may not be materially affected by memory bandwidth. Memory configuration is a balance between memory bandwidth and future capacity growth. It is advisable to match the number of memory options to the
    number of CPUs. (Case B)
  • Data mining can benefit from additional memory bandwidth. In these cases, configure four memory options, two per
    CPU. (Case A)
  • The most demanding high-performance technical applications achieve a performance level that is directly proportional to memory bandwidth. In these cases, configure four memory options, two per CPU. (Case A)
  512-MB RDRAM Memory (4x128) Option
3X-MS7AB-AA
  512-MB RDRAM Memory (1x128) RAID Option
3X-MS7AB-AC
  1-GB RDRAM Memory (4x256) Option
3X-MS7AB-BA
  1-GB RDRAM Memory (1x256) RAID Option
3X-MS7AB-BC
  2-GB RDRAM Memory (4x512) Option
3X-MS7AB-CA
  2-GB RDRAM Memory (1x512) RAID Option
3X-MS7AB-CC
  4-GB RDRAM Memory (4x1024) Option
3X-MS7AB-DA
  4-GB RDRAM Memory (1x1024) RAID Option
3X-MS7AB-DC
  VRM/Bracket Kit for 4-GB RDRAM Memory Option
3X-H7188-AA
  NOTE: Order one VRM/Bracket Kit for each CPU Building Block module that will contain any 3X-MS7AB-DA options.  


Step 5 - Select System Disk

 

  • Mandatory selection of at least one system disk drive is required for each ES47 Tower system ordered.
    NOTE: Integrated Ultra3 SCSI controller for internal disk drives and cabling included.
  • ES47 Tower systems support up to two internal hard disk drives.
  36.4-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive
3R-A3838-AA
  72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive
3R-A3839-AA
  146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive
3R-A3841-AA
  18.2-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive
3R-A3848-AA
  36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive
3R-A3849-AA
  72.8-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive
3R-A3851-AA


Step 6 - Tower Enclosure Power Cords - Mandatory

 

  • Mandatory selection of two power cords required for each ES47 Tower system ordered.
    NOTE: Power supplies included with the Base System.
  North America
BN26J-1K
  Australia, New Zealand, 2.5-meter
BN19H-2E
  Central Europe, 2.5-meter
BN19C-2E
  Denmark, 2.5-meter
BN19K-2E
  Egypt, India, South Africa, 2.5-meter
BN19S-2E
  Israel, 2.5-meter
BN18L-2E
  Italy, 2.5-meter
BM19M-2E
  Japan, 2.5-meter, Dentori approved
3X-BN46F-02
  Switzerland, 2.5-meter
BN19E-2E
  UK, Ireland, 2.5-meter
BM19M-2E

I/O Configuration Guidelines:

 

ES47 Tower systems support six total slots spread over three buses (ports). The following table details the internal I/O slots:

Port # Slot # Maximum Bus Speed Signal Voltage Number of Devices Supported
0 1 133 MHz 3.3V
1 – 133 MHz or 66 MHz PCI-X or
1 – 66 or 33 MHz PCI
1 1 66 MHz 3.3V
2 – 66 MHz PCI-X or
2 – 66 MHz PCI or
4 – 33 MHz PCI
2 66 MHz 3.3V
3 66 MHz 3.3V
4 66 MHz 3.3V
3 1 2X AGP 1.5V
1 – 1X or 2X AGP

NOTE: Four 66-MHz PCI devices are supported in Port 1, Slots 1-4; however, they will operate at 33 MHz.



Step 7- Storage
 

Step 7a – Storage Adapters/Controllers.

 

  Maximum # Supported  
 
  Tru64 UNIX OpenVMS  
 
  Per
System
Per
System
Slot Type
  
SCSI
PCI 2-port Ultra3 (LVD) SCSI adapter, 64-bit/66-MHz dual-channel (uses one PCI slot); includes internal 68-pin and external 68-pin VHDCI connectors; requires 3X-BC56J-xx cable to connect adapter to DS-SL13R-Bx shelf. NOTE: Dual bus/shelf and single/bus shelf (DS-SL13R-xx) are supported.
Restrictions: HSZxx RAID controllers not supported; SDLT tape drives not supported; Tru64 UNIX requires graphics adapter to run console utilities (RUN BIOS); OpenVMS not supported in shared bus configurations; maximum cable length 12 meters.
NOTE: Red Hat Linux V7.2 supported option, maximum one per system.
4
4
3.3V
3X-KZPEA-DB
Ultra160 cable, VHDCI to VHDCI
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet)
3X-BC56J-xx
 
 
 
 
 
RAID
 
 
 
 
Ultra160 2-channel internal RAID controller with 128-MB cache
NOTE: Red Hat Linux V7.2 supported option, maximum one per system.
4
1
3.3V
3X-KZPDC-BE
Ultra160 4-channel internal RAID controller with 256-MB cache
NOTE: Red Hat Linux V7.2 supported option, maximum one per system.
4
1
3.3V
3X-KZPDC-DF

NOTES:

 
 
 
 
Ultra160 cable, VHDCI to VHDCI
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet)
 
 
 
3X-BC56J-xx
 
Fibre Channel
 
 
 
 
PCI to 2-Gbit Fibre Channel host bus adapter, 64 bit/66 MHz, single-channel
4
4
3.3V
DS-KGPSA-DA

PCI-X 2-Gbit Fibre Channel Host Bus Adapter
NOTES:

  • Tru64 UNIX: Requires V5.1B with Patch Kit: T64v51bb03as0001-20021229.tar
  • OpenVMS: Requires V7.3-1 with TIMA kit: VMS73_1_SCSI_FIBRE_V0300
  • OpenVMS Clusters: Requires V7.3-1 with TIMA kit: VMS7_31_cLUSTER_V0100
4 4 3.3V
DS-KGPSA-EA
PCI to Fibre Channel host bus adapter, 64 bit-bit/66 MHz
NOTE: Red Hat Linux V7.2 supported option, maximum one per system.
-
-
3.3V
DS-SWLA4-PD
Fibre Channel cable
xx=02, 03, 05, 10, 15, 30, 50 meters
 
 
 
BNGBX-xx

Step 7b - Storage Expansion – Optional  

StorageWorks Model 4314T Standalone Enclosures for Universal Drives Model 4314T Ultra3 SCSI, single-bus tower enclosure, US
DS-SL13T-AA
Model 4314T Ultra3 SCSI, single-bus tower enclosure, International
DS-SL13T-AB
Model 4314T Ultra3 SCSI, single-bus tower enclosure, Japan
DS-SL13T-AJ
NOTE: DS-SL13T enclosures include one 12-foot VHDCI to VHDCI SCSI cable

Universal Disk Drives (Supported in Model 4314T Standalone Enclosures) 36.4-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive
3R-A3838-AA
72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive
3R-A3839-AA
146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive
3R-A3841-AA
18.2-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive
3R-A3848-AA
36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive
3R-A3849-AA

External Tape Storage

AIT Tabletop Tape Drives AIT 35/70-GB 8-mm LVD tabletop tape drive, carbon black, North America;
requires LVD adapter
216885-001
Same as above, International
216885-B31
Same as above, Japan
216885-291
AIT 50/100-GB 8-mm SCSI tabletop tape drive with 120V North America power cord, carbon black; requires Ultra2 (LVD) adapter
157767-002
Same as above, International
157767-B32
Same as above, Japan
157767-292

AIT Hot-plug Tape Drives (for use in StorageWorks Model 4314T Standalone Enclosures)
  • AIT hot-plug tape drives require two Universal slots
 
AIT 35/70-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves
3R-A2396-AA
AIT 50/100-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves
3R-A2779-AA

AIT Autoloaders AIT 35-GB tabletop autoloader, 8 cartridge, U.S.
292355-001
Same as above, International
292355-B31

AIT Tape Libraries SSL2020 AIT tabletop library with one AIT 50-GB drive and 20 slots, LVD
175195-B21
SSL2020 AIT tabletop library with two AIT 50-GB drives and 20 slots, LVD
175195-B22

DAT Tabletop Tape Drives DAT 12/24-GB 4-mm narrow single-ended tabletop SCSI tape, includes 120V North America power cord, requires BN31W-xx SCSI cable
DS-TLZ10-DB
DAT 20/40-GB 4-mm Wide Ultra2 (LVD) tabletop SCSI tape drive with 120V North America power cord, carbon black; requires Ultra2 (LVD) adapter
157770-002
Same as above, International
157770-B32
Same as above, Japan
157770-292

DAT - Tape Drives
(for use in StorageWorks Model 4314T Standalone Enclosures)
DAT 20/40-GB DDS4 hot-plug LVD Universal tape drive, uses two slots in
43xxx shelves
3R-A2780-AA
DAT72 internal tape drive kit
3R-A4544-AA
DAT72 external tape drive kit, U.S.
3R-A4545-AA
DAT72 external tape drive kit, International
3R-A4546-AA
DAT72 hot-plug tape drive kit
3R-A4546-AA

DAT Autoloaders DAT 20/40-GB auto loader external; requires BN31W-xx SCSI cable and
3X-KZPCA-AA, or 3X-DEPVZ-AA adapter, North America
166505-001
Same as above, International
166505-B31
Same as above, Japan
166505-291

DLT/SDLT Tabletop Tape Drives DLT8000 tabletop 40/80-GB DLT external tape drive, carbon black - requires
3X-KZPCA-AA LVD adapter - U.S.
146197-B23
Same as above – Japan
146197-292
SDLT tabletop 110/220-GB external tape drive, carbon black- requires 3X-KZPCA-AA LVD adapter - U.S.
192103-002
Same as above – International
192103-B32
Same as above – Japan
192103-292
SDLT tabletop 160/320-GB external tape drive, carbon black - requires 3X-KZPCA-AA LVD adapter - U.S.
257319-001
Same as above - International
257319-B31
Same as above - Japan
257319-291

DLT/SDLT Tape Libraries MSL5026DLX, DLT tabletop library with one 40/80-GB DLT tape drive, LVD
231821-B21
MSL5026DLX, DLT tabletop library with two 40/80-GB DLT tape drives, LVD
231821-B22
MSL5026SL, SDLT tabletop library with one 110/220-GB SDLT tape drive, LVD; graphite
302511-B21
MSL5026SL, SDLT tabletop library with two 110/220-GB SDLT tape drives, LVD; graphite
302511-B22
MSL5026S2, SDLT tabletop library with one 160/320-GB SDLT tape drive, LVD; graphite
293473-B21
MSL5026S2, SDLT tabletop library with two 160/320-GB SDLT tape drives, LVD; graphite
293473-B21
MSL5000 SDLT2 upgrade drive, all
293475-B21
MSL5052SL SDLT 110/220-GB drive field upgrade, LVD
231823-B22
MSL5052S2, SDLT tabletop library with two 160/320-GB SDLT tape drives, LVD; graphite
293476-B21


Step 8 - Storage Adapters/Controllers
 

Step 8a - Networks and Communications – Mandatory

 

  • Mandatory selection of at least one of the following Ethernet adapters (3X-DE602-BB or 3X-DEGXA-TA) is required for each ES47 Tower system ordered
 
  Maximum # Supported  
  Tru64 UNIX OpenVMS  
  Per
System
Per
System
Slot Type
Ethernet Adapters
PCI (32/64-bit, 33-MHz to 66-MHz) dual-port 10/100 Ethernet (UTP/RJ45s) NIC and Base Module. (One 3X-DE602-TA or 3X-DE602-FA optional add-on daughter card can be combined with this module.) Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
NOTE: Red Hat Linux V7.2 supported option, maximum one per system.
4 4 3.3V
3X-DE602-BB
PCI-X/PCI Single-port 10/100/1000 Mbps (Twisted-pair Copper with RJ45) Gigabit Ethernet NIC. Use BN25G, BN26M, BN24Q, BN28Q or equivalent cables with RJ45 connectors.
NOTES: Only supported in PCI mode. Supported as a cluster interconnect under OpenVMS only. OpenVMS remedial kit required:
EV7 Tima: DEC-AXPVMS–VMS731_EV7-V0100- -4.PCSI
LAN Tima: DEC-AXPVMS-VMS731_LAN-V0100- -4.PCSI
Red Hat Linux V7.2 supported option, maximum one per system.
4 4 3.3V
3X-DEGXA-TA

Step 8b - Networks and Communications – Optional

 

  Maximum # Supported  
 
  Tru64 UNIX OpenVMS  
 
  Per
System
Per
System
Slot Type
 
Ethernet Adapters
Dual-port 10/100 Ethernet (UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined 3X-DE602-BB and 3X-DE602-TA modules provide four 10/100 (UTP/RJ45s) ports in a single PCI slot option. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
NOTE: 3X-DE602-TA cannot be used standalone.
4 4 3.3V
3X-DE602-TA
Single-port 100 Mbps (MMF/duplex-SC) add-on daughter card for use with the 3X-DE602-BB. The combined 3X-DE602-BB and 3X-DE602-FA provides two 10/100 (UTP/RJ45s) and one 100Mbps (MMF/SC) ports in a single PCI slot option. Use BN34A or BN34B cables.
NOTE: 3X-DE602-FA cannot be used standalone.
4 4 3.3V
3X-DE602-FA
PCI-X/PCI Single-port 1000 Mbps (Fiber with duplex-SC) Gigabit Ethernet NIC. Use BN34A, BN34B or equivalent cables with SC connectors.
NOTES: Only supported in PCI mode. Supported as a cluster interconnect under OpenVMS only. OpenVMS remedial kit required:
EV7 Tima: DEC-AXPVMS–VMS731_EV7-V0100- -4.PCSI
LAN Tima: DEC-AXPVMS-VMS731_LAN-V0100- -4.PCSI
Red Hat Linux V7.2 supported option, maximum one per system.
4 4 3.3V
3X-DEGXA-SA
 
     
 
FDDI Controllers
     
 
PCI (32-bit, 33-MHz) to FDDI SAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables.
4 4 3.3V
3X-DEFPA-AC
PCI (32- bit, 33-MHz) to FDDI DAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables.
4 4 3.3V
3X-DEFPA-DC
PCI (32-bit, 33-MHz) to FDDI DAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
4 4 3.3V
3X-DEFPA-MC
PCI (32-bit, 33-MHz) to FDDI SAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
4 4 3.3V
3X-DEFPA-UC
Multimode fiber optic (MMF) 62.5/125um duplex cable with SC-to-MIC connectors, xx = available lengths: (01, 03, and 10) for 1, 3, and 10 meters
     
BN34D-xx
 
Synchronous/Asynchronous Controllers
     
 
PCI (32-bit, 33-MHz) to Dual-port Intelligent Synchronous Communications NIC -- Requires at least one (maximum two) BN34x sync cable listed below
4 2 3.3V
3X-PBXDD-AA
PCI (32-bit, 33-MHz) to Quad-port Intelligent Synchronous Communications NIC -- Requires at least one (maximum four) BN34x sync cable listed below.
4 2 3.3V
3X-PBXDD-AB
Synchronous-specific Cables
     
 
EIA-530 single-port cable
     
3X-BC34G-06
V.24/EIA-232 single-port cable
     
3X-BC34L-06
V.11/x.21 single-port cable
     
3X-BC33S-06
V.35 single-port cable
     
3X-BC34T-06
 
     
 
ATM Adapters
     
 
PCI (32-bit, 33-MHz) to 155 Mbps ATM, Copper NIC with RJ45 connector
Use BN25G-xx, or BN26M-xx cables.
4 4 3.3V
3X-DAPBA-UA
PCI (32-bit, 33-MHz) to 155 Mbps ATM Fiber NIC with SC connector
Use BN34B-xx cable.
4 4 3.3V
3X-DAPBA-FA
 
     
 
Asynchronous Communications
     
 
PCI (32-bit, 33-MHz) to 4-port Async Communications NIC with DB-25 octopus cable.
2 2 3.3V
PBXDA-BA
PCI (32-bit, 33-MHz) to 8-port Async Communications NIC
2 2 3.3V
PBXDA-BB
PCI (32-bit, 33-MHz) to 16-port Async Communications Controller and rackmount 16-port distribution box with RJ45 connectors
2 2 3.3V
PBXDA-AC
Asynchronous Connector Adapters
     
 
RJ45-to-DB-25 Converter Cable
     
CXI01-AC
RJ45-to-DEC MJ11 Converter Cable (8 pack)
     
CXI01-AF
 
Ethernet, FDDI, ATM Cables
     
 
Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-ST connectors. xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters
     
BN34A-xx
Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-SC connectors. xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters
     
BN34B-xx
Category 5e (4-Unshielded Twisted Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. xx = available lengths: (0B, 0E, 01, 03, 04, 07) for 0.2, 0.5, 1, 3, 4, and 7 meters
     
BN25G-xx
Category 5e (4-Twisted Pairs, Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters
     
BN26M-xx
Category 5e (4-Unshielded Twisted Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters
     
BN24Q-xx
Category 5e (4-Twisted Pairs, Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters
     
BN28Q-xx


Step 9 - Graphics – Optional

 

  • Select graphics adapter, monitor, and country-specific keyboard for Tru64 UNIX and OpenVMS systems if required
  Maximum # Supported  
 
  Tru64 UNIX OpenVMS Slot Type
 
ATI RADEON 7500 2D AGP graphics accelerator
NOTE: Red Hat Linux V7.2 supported option, maximum one per system.
4 1 AGP(1)
3X-PBXGG-AB
ATI RADEON 7500 2D PCI graphics accelerator
NOTE: Red Hat Linux V7.2 supported option, maximum one per system.
4 1 3.3V PCI
3X-PBXGG-AA
Tru64 UNIX Open3D license for RADEON 7500 (required for 3D functionality)
     
QL-6ZRA9-AA
OpenVMS Open3D license for RADEON 7500 (required for 3D functionality)
     
QL-0ADA9-AA
Additional Tru64 UNIX media kit for RADEON 7500 (initial kit ships with RADEON card)
     
QA-6ZRAA-H8
Additional OpenVMS media kit for RADEON 7500 (initial kit ships with RADEON card)
     
QA-6ZPAA-H8
(1) Only supported in 2X mode
NOTE: Maximum graphics adapters per system, all types - Tru64 UNIX 4, OpenVMS 1


Step 10 - Mouse, Monitors, and Keyboards

 

Mouse 3-button mouse - USB
3X-PBQWS-WB

PS2 to USB Converter Keyboard and Mouse adapter for USB - allows for connection of a PS2 keyboard and/or mouse to an AlphaServer ES47 Tower System
3R-A4495-AA

Monitors
  • Graphics monitors other than those listed can be used if compatible with SVGA graphics ordered with system
  • A video cable, 6-foot/1.8-meter length, is included with all variants of monitors
  • Video extension cable required if monitor is located more than 1-meter from server
  • Monitors will ship with, but not be integrated with systems.
 

Carbon/Silver Monitors V7550 17-inch (16-inch viewable image size) flat-faced shadow mask color monitor, two-tone (carbon/silver), 0.25mm dot pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO99/ Energy Star compliant, Northern Hemisphere with North America power cord, VGA cable
3R-A4002-AA
Same as above, with Euro power cord
3R-A4201-AA
Same as above, APD, no power cord
3R-A4202-AA
Same as above, Southern Hemisphere, with Australia/New Zealand power cord
3R-A4203-AA
 
S7500 17-inch (16-inch viewable image size) FST multi-frequency color monitor, 2-tone (carbon/silver), 0.24-mm dot pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with PRC power cord CCIB,
VGA cable
3R-A4800-AA
   
P930 19-inch (18-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24-mm aperture grille pitch, VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with North America power cord, VGA cable
3R-A4215-AA
Same as above, with Euro power cord
3R-A4391-AA
Same as above, Taiwan, with North America power cord
3R-A4392-AA
Same as above, Southern Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord
3R-A4393-AA
   
S9500 19-inch (18-inch viewable image size) FST multi-frequency color monitor, 2-tone (carbon/silver), 0.24-mm dot pitch, VGA to 1280 x 1024 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with PRC power cord CCIB, VGA cable
3R-A4801-AA
 
P1130 21-inch (19.8-inch viewable image size) FD Trinitron auto-scanning color monitor, 0.24-mm aperture grille pitch, VGA to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with North America power cord, VGA cable
3R-A4216-AA
Same as above, with Euro power cord
3R-A4396-AA
Same as above, Taiwan, North America power cord
3R-A4397-AA
Same as above, with PRC power cord, CCIB
3R-A4400-AA
Same as above, Southern Hemisphere, with Australia/New Zealand power cord
3R-A4398-AA

Carbon/Silver Flat Panel Monitors TFT1825, 18-inch (18-inch viewable image size) TFT flat panel monitor, 0.28mm pixel pitch, 1600 x 1200 @60Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, one VGA, one DVI-I input connector, North America power cord, VGA and DVI-I cables
3R-A4292-AA
L1530, 15-inch (15-inch viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @60 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA and one DVI-I), North America power cord, VGA and DVI-I cables
3R-A4857-AA
L1530, 15-inch (15inch viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @60 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA and one DVI-I), Euro power cord, VGA and DVI-I cables
3R-A4858-AA

Monitor Power Cords North America, 120V, 75-inch
BN26J-1K
Australia, New Zealand, 2.5-meter
BN19H-2E
Central Europe, 2.5-meter
BN19C-2E
Denmark, 2.5-meter
BN19K-2E
Egypt, India, South Africa, 2.5-meter
BN19S-2E
Israel, 2.5-meter
BN18L-2E
Italy, 2.5-meter
BN19M-2E
Japan, 2.5-meter, Dentori approved
3X-BN46F-02
Switzerland, 2.5-meter
BN19E-2E
UK, Ireland, 2.5-meter
BN19A-2E

Keyboards

Keyboards - USB Keyboard/Language
Tru64 UNIX
USB only
OpenVMS
USB and PS/2
U.S./English/International keyboard
3R-LKQ50-BA
3X-LK463-A2
Arabic keyboard
3R-LKQ50-BR
-
Belgian keyboard
3R-LKQ50-AB
3X-LK463-AB
BHCSY keyboard
3R-LKQ50-AX
-
Canadian/English keyboard
-
3X-LK463-AQ
Canadian/French keyboard
3R-LKQ50-AC
3X-LK463-AC
Cyrillic keyboard (Russian)
3R-LKQ50-BT
3X-LK463-BT
Czech keyboard
3R-LKQ50-BV
3X-LK463-BV
Danish keyboard
3R-LKQ50-AD
3X-LK463-AD
Dutch keyboard
3R-LKQ50-AH
3X-LK463-AH
Finnish keyboard
3R-A4590-AA
3X-LK463-AF
French keyboard
3R-LKQ50-AP
3X-LK463-AP
German keyboard
3R-LKQ50-AG
3X-LK463-AG
Greek keyboard
3R-LKQ50-BH
3X-LK463-BH
Hebrew keyboard
3R-LKQ50-AT
3X-LK463-AT
Hungarian keyboard
3R-LKQ50-BQ
3X-LK463-BQ
Italian keyboard
3R-LKQ50-AI
3X-LK463-AI
Japanese keyboard
3R-LKQ50-AJ
-
Korean keyboard
3R-LKQ50-BK
-
Latin-American keyboard
3R-LKQ50-AR
-
Norwegian keyboard
3R-LKQ50-AN
3X-LK463-AN
Polish keyboard
3R-LKQ50-BP
3X-LK463-BP
Portuguese keyboard
3R-LKQ50-AV
3X-LK463-AV
Romanian keyboard
-
3X-LK463-BL
Simplified Chinese keyboard
3R-LKQ50-CV
-
Spanish keyboard
3R-LKQ50-AS
3X-LK463-AS
Swedish keyboard
3R-LKQ50-AM
3X-LK463-AM
Swiss/French keyboard
3R-LKQ50-AK
3X-LK463-AK
Swiss/German keyboard
-
3X-LK463-AL
Traditional Chinese keyboard
3R-LKQ50-BI
-
Thai keyboard
3R-LKQ50-CB
-
Turkish keyboard
3R-LKQ50-BU
3X-LK463-BU
Turkish/F keyboard
-
3X-LK463-BW
UK keyboard 3R-LKQ50-AE -
Yugoslavian keyboard
-
3X-LK463-BY


Step 11 - System Software

 

Tru64 UNIX
  • Media and documentation required for first system on site
  • Software Processor Code = E
  • Tru64 UNIX base systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server
Tru64 UNIX media and online documentation on CD-ROM
QA-6ADAA-H8
Tru64 UNIX full hard copy documentation
QA-6ADAA-GZ
TruCluster Plus Software Package with licenses for TruCluster Server, Logical Storage Manager and AdvFS Utilities
QP-6R9AC-AA
TruCluster Server license
QL-6BRAC-AA
Logical Storage Manager license
QL-2GVAE-AA
AdvFS Utilities license
QL-0EGAE-AA
Advanced Server for Tru64 UNIX, 25 client concurrent use license
QL-5U29M-3D
Advanced Server for Tru64 UNIX, 50 client concurrent use license
QL-5U29M-3E
Advanced Server for Tru64 UNIX, 100 client concurrent use license
QL-5U29M-3F
Advanced Server for Tru64 UNIX, 250 client concurrent use license
QL-5U29M-3G
Advanced Server for Tru64 UNIX, 500 client concurrent use license
QL-5U29M-3H
Layered products media and documentation for Tru64 UNIX on CD-ROM
QA-054AA-H8
DECnet/OSI end-system function license for Tru64 UNIX
QL-MTJAE-AA
DECnet/OSI extended license for Tru64 UNIX
QL-MTKAE-AA

OpenVMS
  • Media and documentation required for first system on site
  • Software Processor Code = E
  • AlphaServer ES47 Tower OpenVMS systems include Base license with System Manager license and Enterprise Integration Server Package for OpenVMS -- OpenVMS OS media on CD-ROM
  • AlphaStation ES47 Tower OpenVMS systems include Base license, Concurrent Use 1-user license and NAS 150 Client license
  • Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS, DECwindows Motif for OpenVMS Alpha, DECnet-Plus for OpenVMS Alpha End System, Archive/Backup System for OpenVMS Management Tools, Archive/Backup Agent for Windows NT®, Office Server for OpenVMS, Office Server Client Access, PATHWORKS 32, PATHWORKS for OpenVMS and Advanced Server.
  • OpenVMS Concurrent Use licenses provide the right to interactively use the operating system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS Concurrent Use licenses can be moved from one system to another at user discretion and can be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster.
  • OpenVMS Traditional Unlimited Use license is system specific and can only be used on one single system at a time. It cannot be shared between systems or in an OpenVMS VAX or OpenVMS Alpha Cluster.
  Concurrent Use 1-user license
QL-MT3AA-3B
  Concurrent Use 2-user license
QL-MT3AA-3C
  Concurrent Use 4-user license
QL-MT3AA-3D
  Concurrent Use 8-user license
QL-MT3AA-3E
  Concurrent Use 16-user license
QL-MT3AA-3F
  Concurrent Use 32-user license
QL-MT3AA-3G
  Concurrent Use 64-user license
QL-MT3AA-3H
  Concurrent Use 128-user license
QL-MT3AA-3J
  Concurrent Use 256-user license
QL-MT3AA-3K
  Traditional unlimited-user license
QL-MT2AE-AA
  OpenVMS media and online documentation on CD-ROM
QA-MT1AA-H8
  OpenVMS hard copy documentation
QA-001AA-GZ
  OpenVMS base hard copy documentation
QA-09SAA-GZ
  OpenVMS Alpha Software Products Library Package: Layered products media and documentation for OpenVMS on CD0ROM, includes media and documentation for all products licensed in the Enterprise Integration Package.
QA-03XAA-H8
  OpenVMS Cluster license for Alpha systems
QL-MUZAC-AA
  OpenVMS Cluster Client license for Alpha systems
QL-3MRAC-AA
  OpenVMS Cluster Client to Full VMS Cluster Migration license
QL-6J7AC-AA
  DECnet-Plus/DECnet extended function license for OpenVMS
QL-MTGAE-AA
  DECnet-Plus/DECnet end-system to extended function upgrade license for OpenVMS
QL-MTHAE-AA
  OpenVMS Volume Shadowing license
QL-2A1AE-AA
  A more complete software list can be found at:
http://www.openvms.compaq.com/swcat/index.html
 

OpenVMS Galaxy Licensing Requirements For more details about OpenVMS Galaxy licensing requirements, refer to Software Product Description for the Galaxy Software Architecture on OpenVMS Alpha, SPD 70.44.xx
 
  • OpenVMS SMP License (included in Dual CPU Building Block Module) is mandatory for each CPU.
  • For each AlphaServer ES47 CPU in an OpenVMS Galaxy, one OpenVMS Galaxy License is mandatory
  • HP layered products are licensed as follows:
    • One capacity license per system
    • One user license per user
  • One capacity license per system
  • One user license per user
  • One OpenVMS Base Operating System License is mandatory for an AlphaServer ES47 configured as an OpenVMS Galaxy system
  Maximum instances per system or hard partition for ES47/ES80:  
  ES47
AlphaStation, Tower, and Model 2
ES47/ES80
Model 4
ES80
Model 6
ES80
Model 8
CPUs
2
4
6
8
Instances
1
2
4
8
  For more information about OpenVMS Galaxy requirements, configurations, and procedures, refer to the OpenVMS Alpha Galaxy Guide. The latest version is always available at http://h71000.www7.hp.com/availability/AA-REZQE-TE.pdf  
  Galaxy 1-CPU License
QL-66XAA-3B
  Galaxy 2-CPU License
QL-66XAA-3C
  Galaxy 4-CPU License
QL-66XAA-3D
  Galaxy 8-CPU License
QL-66XAA-3E
  Galaxy 16-CPU License
QL-66XAA-3F
  Example: 2 CPU ES47 Tower system in which all processors are licensed for OpenVMS and Galaxy  
 
  • Base system order would include a DY-20AAA-AB and one 3X-KN73A-BC Dual CPU Building Block module
  • One QL-66XAA-3C Galaxy 2-CPU license for a total of two Galaxy licenses for the 2-CPU hard partition with Galaxy
 


Step 12 - Hardware and Software Support Services


  • Select one of the optional HP Care Pack Service Packages described below that best supports the customer's operational requirements for system availability.

HP Care Pack Services
  • HP Care Pack Services are available for AlphaServer systems running Tru64 UNIX or OpenVMS operating systems. HP Care Pack Services are designed for customers who require support beyond that provided by the hardware product warranty with coverage for both Principal servers systems and SSPs (Subsequent System Packages) - that meet a full range of customer support requirements.
 

Program Features – Principal Server  
HP Support Plus
  • 13x5 HW/SW support
  • 4-hour response on-site hardware support
  • 2-hour response for software support
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
 

HP Support Plus 24
  • 24x7 HW/SW support
  • Named HW engineer
  • 4-hour response on-site hardware support
  • 2-hour response for software support
  • License Subscription for HP O/S software and embedded L/P (i.e., EIS for OpenVMS, unlimited users, and server extensions for Tru64 UNIX)
  • Consolidated Software Media Update Distribution for OpenVMS or Tru64 UNIX and their layered products. (Some layered products on Consolidated Media Update Distribution can be ordered separately.)
 

Program Features – Additional Services  
SSPs (Subsequent System Packages)
  • For HP Care Pack Support Plus and Support Plus 24
  • HW Support at same level as corresponding package for Principal server
  • License Subscription: HP O/S (where applicable)
  • Telephone support through Principal server covered by full support package
 

Installation
  • Pre-installation review
  • Unpacking of equipment
  • Assemble and test
  • Basic product usage info
  • No software installation added
 

Installation and Startup HP O/S
  • Pre-installation review
  • Unpacking of equipment
  • Assemble and test
  • Basic product usage info
  • Install operating systems
  • Product configuration
  • Print and network access
  • Orientation
 

Model/HP Care Pack
Services
Principal Server
1 year
Principal Server
3 years
Subsequent Systems
1 year
Subsequent Systems
3 years
AlphaServer ES47 Tower
HP Support Plus FP-F01GB-12 FP-F01GB-36 FP-F21GB-12 FP-F21GB-36
HP Support Plus 24 FP-F02GB-12 FP-F02GB-36 FP-F22GB-12 FP-F22GB-36
Installation FP-FINST-GB FP-FINST-GB FP-FINST-GB FP-FINST-GB
Installation and Startup FP-FSTAR-GB FP-FSTAR-GB FP-FSTAR-GB FP-FSTAR-GB

NOTES:

  • AlphaServer ES47 Tower systems include one-year parts and labor warranty with 5x9, on-site Next Business Day response.
  • HP Care Pack Services include support for new HP branded hardware options internal to the AlphaServer enclosure plus a monitor (17-inch or less excluding flat panel models).
  • External storage devices/cabinets carry their own level of warranty and should be quoted separately for uplifted warranty services.
  • In addition to the HP Care Pack Services shown above, other service packages are available for separate hardware and software support. For more information on Hardware and Software Upfront Services and other HP service options available for AlphaServers, please consult your Sales Account Manager, HP Services Principal, or visit: http://www.hp.com/services/
    NOTE: This website is available in English only.

contents
 Overview      Standard Features      Systems      Options      Upgrades      TechSpecs line.gif (50 bytes)

Upgrades

Step 13 - AlphaServer ES47 Tower Upgrades

AlphaServer ES47 Tower can be field upgraded to an AlphaServer ES47 Model 2 with the following options:

  • AlphaServer ES47 Tower to AlphaServer ES47 Model 2 Upgrade Kits

ES47 Tower Upgrades

System expansion hardware and software to upgrade a Tru64 UNIX AlphaServer ES47 Tower to an AlphaServer ES47 Model 2. Includes one rackmount slide kit and one Tru64 UNIX SMP License. See the AlphaServer ES47 QuickSpecs for additional ordering requirements.
3X-BA60B-AA
System expansion hardware and software to upgrade an OpenVMS AlphaServer ES47 Tower to an AlphaServer ES47 Model 2. Includes one rackmount slide kit and one OpenVMS SMP License. See the AlphaServer ES47 QuickSpecs for additional ordering requirements.
3X-BA60B-AF

contents
 Overview      Standard Features      Systems      Options      Upgrades      TechSpecs line.gif (50 bytes)

TechSpecs

Power Requirements      
ES47 Tower System US/Canada Japan Europe
Nominal voltage(s) 100-120/200-240 V * 100-120/200-240V 200-240V
Frequency range 50-60 Hz 50-60 Hz 50-60 Hz
Phases 1 1 1
Rating 10/7A per cord 10/7A per cord 10/7A per cord
Receptacle (site) IEC 320 C13 to Country Specific IEC 320 C13 to Country Specific IEC 320 C13 to Country Specific
* 100-120V operation requires that two power supplies be present; power supply redundancy is not provided during 100-120V operation

Physical Characteristics

Dimensions (H x W x D)

20.1 x 8.6 x 35 in (51 x 22 x 90 cm)
Shipping Dimensions 48 x 30 x 18.5 in (122 x 76 x 47 cm)
Weight Maximum Configuration 132 lb (59 kg)    
Shipping Weight - Maximum Configuration - cardboard outside wrap not included 164 lb (73 kg)    
Heat dissipation Minimally configured system 783W / 2672 Btu/hr  
Fully configured system 850W / 2701 Btu/hr  
Clearances Operating Service  
Front 6 in (15 cm) 6 in (15 cm)  
Rear 6 in (15 cm) 6 in (15 cm)  
Left Side None None  
Right Side None 29.5 in (75 cm)  
Environmental      
Temperature 50 to 104° F (10 to 40° C) -40 to 151° F (–40 to 66° C)
Humidity 10% to 90% 10% to 95%, Storage (60 days) 115° F/46° C
Altitude 10,000 ft (3,050 m) 40,000 ft (12,200 m)  
  NOTE: Maximum operating temperature at sea level; reduce by 1.8° F (1° C) for each 2,000 ft (600 m) above sea level
Vibration 10 to 500 Hz 0.1G peak 1.03 Grms 5-300 Hz  
Shock 5G 30ms, half sine    
Acoustics (Declared values per ISO 9296 and ISO 7779)  
  Idle/Operating (Bystander pos.)  
Description LwAd, B LpAm, dBA  
ES47 Model 2 6.6 47  
Regulatory  
Agency approvals UL: Listed to UL 60950; cUL: Listed to CAN/CSA-C22.2 No.950 3rd Ed, 1995
CB Report to IEC 950:1991+A1: 1992 + A2: 1993 + A3: 1995 + A4:1996
CB Report to EN60950 (1992) with Amdts. 1, 2, 3, 4 and 11
FCC: Part 15.B Class A
IC ICES-003 Class A
CE: EN55022: 1998, EN55024: 1998, EN61000-3-2: 1995, EN61000-3-3: 1995
VCCI: V-3/02.04 Class A
BSMI: CNS 13438 Class A
C-Tick:AS/NZS 3548:1995 Class A

© Copyright 2003 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

   DA-11508 - U.S. - Version 20 - November 14, 2003