| Processor | 2 to 16 Alpha 21364 1150-MHz CPUs (in multiples of two) | ||
|
|
|||
| Cache Memory | 1.75-MB ECC L2 on-chip cache per CPU | ||
|
|
|||
| Architecture |
Glue-less processor-to-processor multiprocessor architecture constructed
from a set of basic components: |
||
|
|
|||
| CPUs, Memory, and I/O slots | GS1280 Model 8 | GS1280 Model 16 |
| Maximum CPUs supported | 8 | 16 |
| Maximum memory supported | Up to 64 GB | Up to 128 GB |
| Maximum PCI/PCI-X slots supported | 87 | 176 |
| Maximum AGP slots supported | 8 | 16 |
|
|
| Interfaces | USB | One Dual USB port per System Building Block Drawer |
| Server Management | One MBM Server Management LAN Connection per System Building Block Drawer | |
| Serial | One MBM serial connection per System Building Block Drawer | |
|
|
||
| Form Factor | 41U Rack | ||
|
|
|||
| Boot/Diagnostic Devices | CD-R | One slim line multi-bay 24X/10X/24X CD-RW in Master I/O Drawer | |
| Hard Drives | Choice of 18.2/36.4/72.8/146-GB SCSI disk drives in Master I/O Drawer | ||
|
|
|||
| Power Supplies | 3-phase power subsystem with
power cords, redundant 48 Vdc hot swap power supplies included Cabinet configurations require 3-phase power distribution units, North America or an International variant |
|
|
|
| OS Support | AlphaServer GS1280 Tru64 UNIX systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server |
| AlphaServer GS1280 OpenVMS systems include pre-installed software, Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS | |
| Minimum OS support - Tru64 UNIX V5.1B + IPK or OpenVMS V7.3-1 plus Update Kit | |
|
|
|
| Service and Support | Protected by HP Services including a 1-year on-site hardware warranty. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support. |
| NOTE: For the
complete list of supported options, refer to the following Web page: http://h18002.www1.hp.com/alphaserver/options/asgs1280/asgs1280_options.html |
|
|
Systems
| Step 1 - Assess Application Requirements |
|
|
|
| NOTE: Most configuration steps require that the above data be considered in whole or in part. Be sure to execute each step in the context of the total application requirements. |
|
|
| Configuration Requirements for GS1280 Partitions |
|
|
|
Configuring partitions requires some attention to detail with respect to minimum requirements for option selection, population, and option placement.
|
|
All systems require the following minimum firmware revisions to run hard
partitions:
|
| NOTE: Additional partitioning
information is available at http://h18003.www1.hp.com/alphaserver/gs1280/gs1280_tech.html |
|
|
| Minimum Hardware Required per AlphaServer GS1280 Hardware Partition |
|
|
|
| AlphaServer GS1280 systems are normally configured according to standard module placement rules, and are shipped with one copy of the operating system installed at the factory (Tru64 UNIX or OpenVMS). However, systems with hardware partitions offer hardware and software configuration flexibility. Factory integration services (VIS) are recommended to enable custom module configuration and factory installation of multiple copies of the operating system on hardware- partitioned systems. |
|
|
|
| System Software Required for AlphaServer GS1280 Hardware Partition Support - Software Licensing for Hardware Partitions |
|
|
|
|
|
| Licensing AlphaServer GS1280 Systems for Both OpenVMS and Tru64 UNIX | |
|
|
|
| Systems require licenses for both OpenVMS and Tru64 UNIX operating systems, either for dual O/S boot of the entire system or for different operating systems in separate hard partitions. One operating system license is included in the base system and the second is added as a line item. The second operating system license upgrade would be added to the order using the following part numbers. Order appropriate media and documentation kits from Step 16. | |
|
QB-63PAQ-AC |
|
QB-595AN-AB |
|
|
|
QL-MT1A9-6T |
|
QL-MT4A9-6T |
|
|
|
Example 1: 16-CPU GS1280 system in which all processors are licensed
for both OpenVMS and Tru64 UNIX:
|
|
|
Example 2: 16-CPU GS1280 system in which all the processors are
licensed for Tru64 UNIX and eight processors are also licensed for OpenVMS:
|
|
|
Example 3: 16-CPU GS1280 system in which eight processors are
licensed for Tru64 UNIX and eight processors are also licensed for OpenVMS:
|
|
|
|
|
| System Ordering Requirements: | |
|
|
|
|
Certain system components or services are either required for normal
operation or are recommended for best system performance and/or operation.
This document uses the following definitions to specify these options:
|
|
|
|
|
AlphaServer GS1280 Model 8 and Model 16 systems require selection of the following items: |
|
|
Mandatory Purchases:
|
|
|
Optional Purchases:
|
|
|
Recommended Services:
|
|
|
|
|
System Management Hardware/Software Requirements |
|
|
|
|
|
NOTE: The following Server Management requirements only apply to customers who prefer to use the AMS or AMU Server Management software.
|
|
|
|
Step 2 - Select base system |
|
|
|
|
|
Mandatory selection of at least one Base System required |
|
|
Base Systems Include:
NOTE: Base systems do not include CPUs or memory (see Steps 3 and 4) |
|
|
|
|
|
AlphaServer GS1280 Base Systems
|
|||||
| Model | OS | System Building Block Drawers Included | Total CPUs Supported (See Step 3) |
41U Rack(s) | Order No. |
| Model 8 | Tru64 UNIX | 1 | 8 | One Included | DA-1280A-AA |
| Model 8 | OpenVMS | 1 | 8 | One Included | DY-1280A-AA |
| Model 16 | Tru64 UNIX | 2 | 16 | One Included | DA-1280A-BA |
| Model 16 | OpenVMS | 2 | 16 | One Included | DY-1280A-BA |
|
|
Step 3 - CPU Building Block Modules - Mandatory |
|
|
|
|
|
|
CPU Building Block Modules |
AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1150 MHz, Tru64 UNIX SMP License |
3X-KN72C-AB
|
| AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1150 MHz, OpenVMS SMP License |
3X-KN72C-AC
|
|
|
|
||
|
Capacity on Demand (CoD) CPU Building Block Modules |
AlphaServer GS1280 Systems can
be configured with optional Capacity on Demand (CoD) CPUs for future capacity
expansion. The total number of CPU Building Block Modules plus CoD CPU Building
Bock Modules must adhere to the limits outlined above for GS1280 Model 8
and Model 16 systems. Memory is NOT included with CoD CPUs but must be ordered.
See Step 4 for memory configuration requirements. NOTE: An inactive CoD CPU cannot be connected to an external I/O Expansion Drawer. |
|
| AlphaServer GS1280 CoD Dual CPU
Building Block Module, 1150 MHz, Tru64 UNIX SMP License |
3X-KN72C-CB
|
|
| AlphaServer GS1280 CoD Dual CPU Building Block Module, 1150 MHz, OpenVMS SMP License |
3X-KN72C-CC
|
|
|
|
||
|
|
Options
| Step 4 - Select Memory Options | |
|
|
|
| Memory Configuration Guidelines | |
| Memory options should be selected in the context of the application's sensitivity to memory bandwidth and future memory expansion. This will determine the number of memory options to order. The total capacity required will determine the size of the options to be ordered. | |
|
Mandatory selection of at least two memory options per CPU Building Block Module ordered in Step 3.
The following examples illustrate different ways of configuring a GS1280 Model 8 with four CPUs with a total of 4-GB of memory. |
|
|
|
|
| CPU Building Block Module #1 | CPU Building Block Module #2 | ||||||||
| Case | Memory Option | CPU 1 | CPU 2 | CPU 3 | CPU 4 | ||||
| Controller 1 | Controller 2 | Controller 1 | Controller 2 | Controller 1 | Controller 2 | Controller 1 | Controller 2 | ||
|
A |
3X-MS7AB-AA (4x128 MB) | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| B | 3X-MS7AB-BA (4x256 MB) | 1 | - | 1 | - | 1 | - | 1 | - |
|
|
|
Memory Application Examples |
||
|
|
||
|
Configuring memory is a compromise between cost, total memory capacity,
and memory bandwidth requirements. The behavior of the application must
be used to define the most-desired configuration. Some applications are
sensitive to memory capacity, some are sensitive to memory bandwidth,
some are sensitive to neither. If actual application measurements are
not available, the following may be used as guidelines:
|
||
| 512-MB RDRAM Memory (4x128) Option |
3X-MS7AB-AA
|
|
| 512-MB RDRAM Memory (1x128) RAID
Option |
3X-MS7AB-AC
|
|
| 1-GB RDRAM Memory (4x256) Option |
3X-MS7AB-BA
|
|
| 1-GB RDRAM Memory (1x256) RAID
Option |
3X-MS7AB-BC
|
|
| 2-GB RDRAM Memory (4x512) Option |
3X-MS7AB-CA
|
|
| 2-GB RDRAM Memory (1x512) RAID
Option |
3X-MS7AB-CC
|
|
| 4-GB RDRAM Memory (4x1024) Option |
3X-MS7AB-DA
|
|
| 4-GB RDRAM Memory (1x1024) RAID
Option |
3X-MS7AB-DC
|
|
| VRM/Bracket Kit for 4-GB RDRAM
Memory Option |
3X-H7188-AA
|
|
| NOTE: Order one VRM/Bracket Kit for each CPU Building Block module that will contain any 3X-MS7AB-DA options | ||
|
|
||
|
Step 5 - Configure Packaging Options |
|
|
|
|
| Step 5a - System I/O Expansion | |
|
|
|
|
I/O Configuration Guidelines: |
||
|
|
||
Example GS1280 Model 8:
|
||
|
Standard I/O Drawer
|
||
|
|
||
|
Master and Expansion Standard I/O Building Block Drawer
slot specifications:
|
||||
| Port # | Slot # | Maximum Bus Speed | Signal Voltage | Number of Devices Supported |
| 0 | 1 | 33 MHz | 3.3V |
1 33 MHz PCI
|
| 2 | 33 MHz | 5.0V |
1 - CIPCA-BA or
2 - 3X- KZPBA-CC (NOTE: No mixing of options within 5V slots) |
|
| 3 | 33 MHz | 5.0V | ||
| 1 | 1 | 133 MHz | 3.3V |
2 66 or 33 MHz PCI or
2 66 MHz PCI-X or 1(1) 133 MHz PCI-X |
| 2 | 133 MHz | 3.3V | ||
| 2 | 1 | 66 MHz | 3.3V |
6 33 MHz PCI or
3(2) 66 MHz PCI or 2 66 MHz PCI- X |
| 2 | 66 MHz | 3.3V | ||
| 3 | 66 MHz | 3.3V | ||
| 4 | 66 MHz | 3.3V | ||
| 5 | 66 MHz | 3.3V | ||
| 6 | 66 MHz | 3.3V | ||
| 3 | 1 | 2X AGP | 1.5V |
1 1X or 2X AGP
|
|
NOTE: (1) Two 133-MHz PCI-X devices are supported in Port 1,
slots 1 and 2; they will however operate at 100 MHz. |
||||
|
|
|
Modules designed for 5.0V signaling and 33-MHz bus speed
can only operate in Port 0 - slots 2 and 3 (reserved for 3X-KZPBA-CC or
CIPCA) |
||
|
High Performance I/O Drawer
|
||
|
|
| The following chart details the High Performance I/O Drawer slots: | ||||
|
Port #
|
Slot #
|
Maximum Bus Speed
|
Signal Voltage
|
Number of Devices Supported
|
|
0
|
Slot 1, 2
|
133 MHz
|
3.3V
|
2 - 133 MHz PCI-X
|
|
1
|
Slot 1, 2
|
133 MHz
|
3.3V
|
2 - 133 MHz PCI-X
|
|
2
|
Slot 1, 2
|
133 MHz
|
3.3V
|
2 - 133 MHz PCI-X
|
|
3
|
Slot 1, 2
|
133 MHz
|
3.3V
|
2 - 133 MHz PCI-X
|
| NOTE: 5V and AGP options are not supported | ||||
|
|
| Standard I/O Master Drawer |
3X-BA70A-AA
|
|
| Standard I/O Expansion Drawer
|
3X-BA70A-BA
|
|
| High Performance I/O Master Drawer
|
3X-BA70B-AA
|
|
| High Performance I/O Expansion
Drawer |
3X-BA70B-BA
|
|
| Add-in I/O Module for High Performance
I/O Drawers. Each module supports two PCI/PCI-X slots. Up to three modules
may be added to the base High Performance I/O Drawer. |
3X-KFMHA-AA
|
|
| I/O 3.3-meter cable for connection
between a GS1280 System Building Block Drawer and I/O Building Block Drawers
mounted in a system cabinet or adjacent expansion cabinet; select one cable
for each I/O drawer ordered and one cable per Add-in I/O Module (3X-KFMHA-AA)
if ordered. |
3X-BNPSA-04
|
|
| I/O 4.5-meter cable for connection
spanning one or two cabinets between a GS1280 System Building Block Drawer
and I/O Building Block Drawer mounted in optional 3X-H9A45-ZA cabinet (see
Step 8); select one cable for each I/O drawer ordered and one cable per
Add-in I/O Module (3X-KFMHA-AA) if ordered. |
3X-BNPSA-05
|
|
| I/O 6.0-meter cable for connection spanning three cabinets between a GS1280 System Building Block Drawer and I/O Building Block Drawer mounted in optional 3X-H9A45-ZA cabinet (see Step 8); select one cable for each I/O drawer ordered and one cable per Add-in I/O Module (3X-KFMHA-AA) if ordered. |
3X-BNPSA-06
|
|
|
|
||
|
Step 5b - Select System Disk |
||
|
|
||
|
||
| 36.4-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive |
3R-A3838-AA
|
|
| 72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive |
3R-A3839-AA
|
|
| 146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive |
3R-A3841-AA
|
|
| 18.2-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive |
3R-A3848-AA
|
|
| 36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive |
3R-A3849-AA
|
|
| 72.8-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive |
3R-A3851-AA
|
|
|
|
||
|
|
|
|
|
![]() |
|
AlphaServer GS1280 Model 8 - Internal System Expansion
Options
|
|
|
![]() |
|
AlphaServer GS1280 Model 16 - Internal System Expansion
Options
|
|
|
|
|
||
|
|
||
| Power Distribution Units |
|
|
| 120/208V Y or 200V, 30A NEMA L21-30P plug 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AA
|
|
| 380/415V Y, IEC 309 32A 6h/230/400~ plug 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AB
|
|
|
|
||
| Dual AC Power Options for GS1280 Model 8 and Model 16 Systems |
|
|
| Dual AC option for use with AlphaServer GS1280 Model 8 systems |
3X-H7514-AC
|
|
| Dual AC option for use with AlphaServer GS1280 Model 16 systems |
3X-H7514-AB
|
|
![]() |
||
|
AlphaServer GS1280 Model 8 with Dual AC Option
|
||
|
|
||
![]() |
||
|
AlphaServer GS1280 Model 16 with Dual AC Option
|
||
|
|
||
| Step 8 - External Cabinet Expansion |
||
|
|
||
|
||
| NOTE: Not required if dual AC power was selected in Step 7 for Model 16 system. | ||
| External Expansion Cabinet |
3X-H9A45-ZA
|
|
| 120/208V Y or 200V, NEMA L21-30P plug 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AA
|
|
| 380/415V Y, IEC 309 32A 6h/230/400~ plug 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AB
|
|
![]() |
||
|
AlphaServer GS1280 Model 8 or Model 16 External Cabinet
Expansion
|
||
|
|
||
|
|
||
|
|
||
| Maximum # Supported | ||||||||
| Tru64 UNIX | OpenVMS |
|
||||||
| Per Model 8 System |
Per Model 16 System |
Per External I/O Drawer | Per Model 8 System |
Per Model 16 System |
Per External I/O Drawer | Slot Type | ||
|
SCSI -- NOTE:
Maximum storage controllers per systems, all types - Tru64 UNIX:
32, OpenVMS: 26
|
||||||||
|
PCI 2-port Ultra3 (LVD) SCSI adapter, 64-bit/66-MHz dual-channel
(uses one PCI slot); includes internal 68-pin and external 68-pin VHDCI
connectors; requires 3X-BC56J-xx cable to connect adapter to DS-SL13R-Bx
shelf.
NOTE: Dual bus/shelf and single/bus shelf (DS-SL13R-xx) are supported. Restrictions: HSZxx RAID controllers not supported; SDLT tape drives not supported; Tru64 UNIX requires graphics adapter to run console utilities (RUN BIOS); OpenVMS not supported in shared bus configurations; maximum cable length 12 meters. |
32 | 32 | 8 | 12 | 12 | 8 | 3.3V |
3X-KZPEA-DB
|
|
PCI 1-port Ultra2 (LVD) SCSI adapter, 32-bit/33-MHz, single-channel
(uses one PCI slot); includes internal 68-pin and external 68-pin HD connectors;
order BN38C-xx cable to connect adapter to Ultra3 shelf, or order VHDCI
converter (BN38E-0B) for use with included cable. HSZxx RAID controllers
not supported. No support for shared SCSI.
|
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-KZPCA-AA
|
|
Ultra160 cable, VHDCI to VHDCI
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet) |
3X-BC56J-xx
|
|||||||
|
PCI 1-port UltraSCSI wide differential 32-bit/33-MHz PCI
adapter (uses one PCI slot); includes external 68-pin HD connector, requires
BN38C-xx cable (2 to 25 meters) to connect adapter to differential UltraSCSI
shelf or RAID controller
|
4 | 8 | 2 | 4 | 8 | 2 | 5V |
3X-KZPBA-CC
|
|
68-pin HD male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20 meters |
BN38C-xx
|
|||||||
|
RAID
|
|
|||||||
|
Ultra160 2-channel internal RAID controller with
128-MB cache. |
8 | 8 | 8 | 1 | 1 | 1 | 3.3V |
3X-KZPDC-BE
|
|
Ultra160 4-channel internal RAID controller with
256-MB cache. |
8 | 8 | 8 | 1 | 1 | 1 | 3.3V |
3X-KZPDC-DF
|
|
NOTES:
|
|
|||||||
|
Ultra160 cable, VHDCI to VHDCI
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet) |
3X-BC56J-xx
|
|
Fibre Channel
|
|
|||||||
|
PCI to 2-Gb Fibre Channel adapter, 64-bit/66-MHz, single-channel
|
24 | 32 | 8 | 15 | 26 | 8 | 3.3V |
DS-KGPSA-DA
|
|
PCI-X 2-Gbit Fibre Channel Host Bus Adapter
|
32 | 32 | 8 | 26 | 26 | 8 | 3.3V |
DS-KGPSA-EA
|
|
Fibre Channel cable (BNGBX-xx)
xx=02, 03, 05, 10, 15, 30, 50 meters |
BNGBX-xx
|
|||||||
|
|
|
|||||||
|
CIPCA
|
|
|||||||
|
PCI CI adapter, requires two PCI slots
Each PCI CI adapter ordered requires the mandatory selection of an I/O Expansion Drawer (see Step 6) |
NA | NA | NA | 2 | 4 | 1 | 5V |
CIPCA-BA
|
|
Computer interconnect cable set, connects CIPCA to star
coupler; select length xx=10, 20, 45 meters
|
BNCIA-xx
|
|
|
|
|
||
|
|
||
| StorageWorks Model 4314R and Model 4354R Universal Drive Shelves | ||
| StorageWorks Model 4314R and 4354R Ultra3 SCSI (LVD) single-bus and split-bus Universal drive shelves; refer to StorageWorks Enclosure 4300 Family QuickSpecs when configuring shelves. When selecting a DS-SL13R-Bx split-bus shelf, two SCSI channels are required. No support for Model 4314R or 4314T single-bus shelves with 3X-KZPEA-DB adapter. Note that the depth of a DS-SL13R-xx shelf does not allow front and rear mounting. NOTE: DS-SL13R single-bus shelves include one 12-foot VHDCI to VHDCI SCSI cable; dual-bus shelves include two 12-foot VHDCI TO VHDCI SCSI cables. | ||
| StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply. No support for Model 4314R single-bus shelves with embedded Ultra3 SCSI adapter or 3X-KZPEA-DB adapter |
DS-SL13R-AA
|
|
| StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply. No support for Model 4314R single-bus shelves with embedded Ultra3 SCSI adapter or 3X-KZPEA-DB adapter |
DS-SL13R-AJ
|
|
| StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power supplies, U.S. |
DS-SL13R-BA
|
|
| StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power supplies, Japan |
DS-SL13R-BJ
|
|
|
|
||
| Disk Drives (Supported in Model 4314R and 4354R Universal Drive Enclosures) | 36.4-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive |
3R-A3838-AA
|
| 72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive |
3R-A3839-AA
|
|
| 146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive |
3R-A3841-AA
|
|
| 18.2-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive |
3R-A3848-AA
|
|
| 36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive |
3R-A3849-AA
|
|
| 72.8-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive |
3R-A3851-AA
|
|
|
|
||
| Step 11 - Storage Options |
||
|
|
||
| Step 11a Tape Devices | ||
|
|
||
|
AIT Hot-plug Tape Drives (for use in StorageWorks Model 4314R and 4354R Universal Drive Shelves) |
|
|
| AIT 35/70-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves |
3R-A2396-AA
|
|
| AIT 50/100-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves |
3R-A2779-AA
|
|
|
|
||
|
AIT Autoloaders |
AIT 35-GB rackmount autoloader, 8 cartridge, U.S. |
280349-001
|
| Same as above, International |
280349-B31
|
|
| AIT Rail kit for rackmount autoloader |
284930-001
|
|
|
|
||
|
AIT Tape Libraries |
SSL2020 AIT rackmount library with one AIT 50-GB drive and 20 slots, LVD |
175196-B21
|
| SSL2020 AIT rackmount library with two AIT 50-GB drives and 20 slots, LVD |
175196-B22
|
|
|
|
||
|
DAT Tape Drives |
DAT 20/40-GB DDS4 hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves |
3R-A2780-AA
|
| DAT72 internal tape drive kit |
3R-A4544-AA
|
|
| DAT72 external tape drive kit, U.S. |
3R-A4545-AA
|
|
| DAT72 external tape drive kit, International |
3R-A4546-AA
|
|
| DAT72 hot-plug tape drive kit |
3R-A4546-AA
|
|
|
|
||
|
DLT/SDLT Tape Libraries |
MSL5000 Embedded Fibre Option Kit, graphite, one card, 1 FC x 2 LVD |
3R-A3746-AA
|
| MSL5000 Embedded Fibre Option Kit, opal, one card, 1 FC x 2 LVD |
3R-A3871-AA
|
|
| MSL5026DLX, DLT rackmount library with one 40/80-GB DLT tape drive, LVD |
231891-B21
|
|
| MSL5026DLX, DLT rackmount library with two 40/80-GB DLT tape drives, LVD |
231891-B22
|
|
| MSL5026SL, SDLT rackmount library with one 110/220-GB SDLT tape drive, LVD; graphite |
302512-B21
|
|
| MSL5026SL, SDLT rackmount library with two 110/220-GB SDLT tape drives, LVD; graphite |
302512-B22
|
|
| MSL5026S2, SDLT rackmount library with 0 drives, LVD; graphite |
293472-B21
|
|
| MSL5026S2, SDLT rackmount library with one 160/220-GB SDLT tape drive, LVD; graphite |
293472-B22
|
|
| MSL5026S2, SDLT rackmount library with one 160/220-GB SDLT tape drive, LVD; graphite |
293472-B23
|
|
| MSL5026S2, SDLT rackmount library with one 160/220-GB SDLT tape drive, Fibre Channel Interface; graphite |
293472-B24
|
|
| MSL5026S2, SDLT rackmount library with two 160/220-GB SDLT tape drives, Fibre Channel Interface; graphite |
293472-B25
|
|
|
|
MSL5000 SDLT2 upgrade drive, all |
293475-B21
|
| MSL5052SL SDLT rackmount library, 0 drives, LVD |
255102-B21
|
|
| MSL5052SL SDLT rackmount library with two 110/220-GB drives, LVD |
249491-B21
|
|
| MSL5052SL SDLT 110/220-GB drive field upgrade, LVD |
231823-B22
|
|
| MSL5052S2, SDLT rackmount library with two 160/220-GB SDLT tape drives, LVD; graphite |
293474-B21
|
|
| MSL5052S2, SDLT rackmount library with two 160/220-GB SDLT tape drives, Fibre Channel Interface; graphite |
293474-B24
|
|
| ESL9322S2 SDLT tape library, with two 160/320-GB SDLT tape drives, 222 slots - requires 3X-KZPCA-AA adapter |
293409-B22
|
|
| ESL9322S2 SDLT tape library, with eight 160/320-GB SDLT tape drives, 222 slots - requires 3X-KZPCA-AA adapter |
293409-B28
|
|
| ESL9322S2 SDLT tape library, with two 160/320-GB SDLT tape drives, 322 slots - requires 3X-KZPCA-AA adapter |
293410-B22
|
|
| ESL9322S2 SDLT tape library, with eight 160/320-GB SDLT tape drives, 322 slots - requires 3X-KZPCA-AA adapter |
293410-B28
|
|
| ESL9000 SDLT2 LVD Upgrade Drive |
293414-B21
|
|
| ESL9595SL SDLT tape library, 0 drives, 400 slots - requires 3X-KZPCA-AA adapter |
274672-B21
|
|
| ESL9595SL SDLT tape library, two drives, 400 slots - requires 3X-KZPCA-AA adapter |
274672-B22
|
|
| ESL9595SL SDLT tape library, 16 drives, 400 slots - requires 3X-KZPCA-AA adapter |
274672-B28
|
|
| ESL9595SL SDLT tape library, 0 drives, 500 slots - requires 3X-KZPCA-AA adapter |
281627-B21
|
|
| ESL9595SL SDLT tape library, two drives, 500 slots - requires 3X-KZPCA-AA adapter |
281627-B22
|
|
| ESL9595SL SDLT tape library, 16 drives, 500 slots - requires 3X-KZPCA-AA adapter |
281627-B28
|
|
| ESL9595SL SDLT tape library, 0 drives, 595 slots - requires 3X-KZPCA-AA adapter |
281628-B21
|
|
| ESL9595SL SDLT tape library, two drives, 595 slots - requires 3X-KZPCA-AA adapter |
281628-B22
|
|
| ESL9595SL SDLT tape library, 16 drives, 595 slots - requires 3X-KZPCA-AA adapter |
281628-B28
|
|
|
|
ESL9595S2 SDLT2 tape library, two drives, 400 slots - requires 3X-KZPCA-AA adapter |
293411-B22
|
| ESL9595S2 SDLT2 tape library, 16 drives, 400 slots - requires 3X-KZPCA-AA adapter |
293411-B28
|
|
| ESL9595S2 SDLT2 tape library, two drives, 500 slots - requires 3X-KZPCA-AA adapter |
293412-B22
|
|
| ESL9595S2 SDLT2 tape library, 16 drives, 500 slots - requires 3X-KZPCA-AA adapter |
293412-B28
|
|
| ESL9595S2 SDLT2 tape library, two drives, 595 slots - requires 3X-KZPCA-AA adapter |
293413-B22
|
|
| ESL9595S2 SDLT2 tape library, 16 drives, 595 slots - requires 3X-KZPCA-AA adapter |
293413-B28
|
|
| ESL9000 SDLT2 LVD upgrade drive |
293414-B21
|
|
| ESL9000 Embedded Fibre Options Kit, 1 FC x 2 LVD SCSI (two cards) with card case |
3R-A3935-AA
|
|
| ESL9000 Embedded Fibre Options Kit, 1 FC x 2 LVD SCSI (two cards) without card case |
3R-A3745-AA
|
|
|
|
||
|
3U Rackmount Tape Drive Enclosure |
3U LVD Rackmount Tape Drive Enclosure |
274338-B21
|
| NOTE: The 3U Rackmount Tape Enclosure supports up to four internal half-height removable devices, or up to two full-height devices; select up to four AIT or DAT devices or two DLT/SDLT devices with 3U Rackmount Tape Enclosure (274338-B21) or select one of the preconfigured configurations listed below. | ||
| AIT 35/70-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
216884-B21
|
|
| AIT 50/100-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
3R-A3753-AA
|
|
| DAT 20/40-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
3R-A3752-AA
|
|
| DLT8000 40/80-GB tape drive, requires 3X-KZPCA-AA LVD adapter |
146196-B22
|
|
| SDLT 110/220-GB tape drive, requires 3X-KZPCA-AA LVD adapter |
192106-B25
|
|
| SDLT 160/320-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
257319-B21
|
|
| Preconfigured configurations | ||
| AIT 50-GB 3U rackmount kit, carbon black |
274333-B21
|
|
| DLT 40/80-GB, 3U rackmount kit, carbon black |
274332-B21
|
|
| DLT 40/80-GB, dual-drive, 3U rackmount kit, carbon black |
274335-B21
|
|
| SDLT 110/220-GB, 3U rackmount kit, carbon black |
274331-B21
|
|
| SDLT 110/220-GB, dual-drive, 3U rackmount kit, carbon black |
274334-B21
|
|
|
|
||
|
5U Rackmount Tape Drive Enclosure |
5U LVD Rackmount Tape Drive Enclosure |
274339-B21
|
| NOTE: The 5U Rackmount Tape Enclosure supports four full-height removable devices; select up to four DLT or SDLT devices with 5U Rackmount Tape Enclosure (274339-B21) or select one of the preconfigured configurations listed below. | ||
| DLT8000 40/80-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
146196-B22
|
|
| SDLT 110/220-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
192106-B25
|
|
| SDLT 160/320-GB tape drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
257319-B21
|
|
| Preconfigured configurations | ||
| SDLT 110/220-GB Tape Array III, 5U rackmount kit, carbon black |
274336-B21
|
|
| DLT 40/80-GB Tape Array III, 5U rackmount kit, carbon black |
274337-B21
|
|
| DLT Tape Array III Model 0 enclosure, U.S. |
168047-001
|
|
| Same as above, International |
168047-B31
|
|
| Same as above, Japan |
168047-291
|
|
|
|
||
|
Step 11b Network Storage Routers |
||
|
|
||
| 1 Fibre Channel x 2 HVD Data Router |
3R-A2673-AA
|
|
| 1 Fibre Channel x 2 LVD Data Router |
3R-A2774-AA
|
|
| 2 x 4 LVD Fiber Channel to SCSI Network Storage Router |
3R-A3740-AA
|
|
| 2 x 4 HVD Fiber Channel to SCSI Network Storage Router |
3R-A3741-AA
|
|
| Network Storage Router 1200 |
3R-A3747-AA
|
|
|
|
||
|
Step 11c External Storage Solutions/Controllers |
||
|
|
||
| 41U graphite storage cabinet, M3220 controller assembly with dual HSV110 controllers, 6 M5214 dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C6D-B, 60 Hz |
DS-SV110-JA
|
|
| 41U graphite storage cabinet, M3220 controller assembly with dual HSV110 controllers, 6 M5214 dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C6D-B, 50 Hz |
DS-SV110-JB
|
|
| 41U graphite storage cabinet, M3220 controller assembly with dual HSV110 controllers, 12 M5214 dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C12D-B, 60 Hz |
DS-SV110-KA
|
|
| 41U graphite storage cabinet, M3220 controller assembly with dual HSV110 controllers, 12 M5214 dual FC loop 14-bay drive enclosures, 4 FC loop switches; Model 2C12D-B, 50 Hz |
DS-SV110-KB
|
|
| Fibre Channel Controller (HSG80), includes 256-MB cache, requires following firmware: |
DS-HSG80-BK
|
|
| - 8.6-4F ACS FW (222318-B22, QB-6BUAA-SD),
one per controller - 8.6-4S ACS FW (222364-B22, QB-6ENAA-SC), one per controller - 8.6-4P ACS FW (222316-B22, QB-6CAAA-SD), one per controller Requires Tru64 UNIX software: 222320-B23, QB-65RAB-SE, one per controller Requires OpenVMS software: 222321-B22, QB-65RAC-SD, one per controller |
||
| Additional 256-MB cache for HSG80 |
DS-HSDIM-AC
|
|
| Single cache battery, one per HSG80 controller |
DS-SE2CS-CB
|
|
| Model 2200 controller shelf for HSG80 controller only supported in 9000 Series and M-Series Cabinets |
DS-SE2ZS-C8
|
|
|
|
||
|
EVA3000 |
The Enterprise Virtual Array 3000
(eva3000) is the mid-range member of the HP StorageWorks virtual disk array
enabled by VersaStor technology. The EVA3000 is designed for the data center
where there is a critical need for ever-increasing capacity/replication
requirements, performance demands, and business continuance needs. Support
is provided for HP StorageWorks Continuous Access, HP StorageWorks Business
Copy, and HP OpenView Storage Operations Management Software. The EVA3000
is a full 2-Gb end-to-end Fibre Channel Array that operates in 1-Gb, 2-Gb,
or mixed 1-Gb/2-Gb SAN fabrics. The EVA3000 is available in one of four integrated "independent bundle" configurations, which includes one pair of HSV100 controllers, two FC drive enclosures, and 8 to 16 FC hard drives (bundle dependent). For ordering information and configuration rules, refer to the EVA3000 QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11619_div/11619_div.html |
|
|
|
||
|
EVA5000 |
The Enterprise Virtual Array 5000
(eva5000) is the mid to high-range member of the HP StorageWorks virtual
disk array enabled by VersaStor technology. The EVA5000 is designed for
the data center where there is a critical need for ever-increasing capacity/replication
requirements, performance demands, and business continuance needs. Support
is provided for HP StorageWorks Continuous Access, HP StorageWorks Business
Copy, and HP OpenView Storage Operations Management Software. The EVA5000
is a full 2-Gb end-to-end Fibre Channel Array that operates in 1-Gb, 2-Gb,
or mixed 1-Gb/2-Gb SAN fabrics. The EVA5000 is available in pre-defined configurations with controllers and expansion configurations without controllers. There is also a pre-defined configuration that is optimized for the High Performance Technical Computing (HPTC) environments. For ordering information and configuration rules, refer to the EVA5000 QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11006_div/11006_div.html |
|
|
|
||
|
Step 11d Fibre Channel Options |
||
|
|
||
| The following disk drives, hubs, switches, and cables are used in Fibre Channel configurations using the DS-KGPSA-xx adapter. | ||
|
|
||
|
Fibre Channel Disk Drives |
36-GB 10K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive |
3R-A3239-AA
|
| 36-GB 15K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive |
3R-A3210-AA
|
|
| 72-GB 10K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive |
3R-A3260-AA
|
|
| 72-GB 15K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive |
3R-A3971-AA
|
|
| 146-GB 15K rpm dual-port 2-Gb/sec FC-AL 1-inch (25.4 mm) drive |
3R-A3975-AA
|
|
|
|
||
|
Fibre Channel Hubs |
StorageWorks Fibre Channel 7-port Storage Hub, International (Tru64 UNIX only) |
DS-SWXHB-I7
|
| StorageWorks Fibre Channel 7-port Storage Hub, North America (Tru64 UNIX only) |
DS-SWXHB-07
|
|
| StorageWorks Fibre Channel 7-port Storage Hub, Japan (Tru64 UNIX only) |
DS-SWXHB-J7
|
|
|
|
||
|
Fibre Channel Switches |
StorageWorks Fibre Channel 2-Gb 8-port SAN Switch |
DS-DSGGD-AC
|
| StorageWorks Fibre Channel 2-Gb 16-port SAN Switch |
DS-DSGGD-AD
|
|
| StorageWorks Fibre Channel 2-Gb 16-port SAN Switch |
DS-DSGGD-BA
|
|
| StorageWorks Fibre Channel 2-Gb 64-port Core Switch |
DS-DSGGE-AB
|
|
| StorageWorks SAN Switch 2-Gb 16-port Base |
DS-DSGGD-CA
|
|
| StorageWorks SAN Switch 2-Gb 16-port Power Pack |
DS-DSGGD-CB
|
|
| StorageWorks SAN Switch 2-Gb 8-port EL |
DS-DSGGD-BC
|
|
| StorageWorks SAN Switch 2-Gb 8-port Power Pack |
DS-DSGGD-CC
|
|
| StorageWorks SAN Switch 2-Gb 32-port Base |
DS-DSGGD-AB
|
|
| StorageWorks SAN Switch 2-Gb 32-port PowerPak |
DS-DSGGD-DB
|
|
| StorageWorks Core Switch 2-Gb 64-port Base |
DS-DSGGE-BA
|
|
| StorageWorks Core Switch 2-Gb 64-port PowerPak |
DS-DSGGE-CA
|
|
|
|
||
|
Fibre Channel Director/Edge Class Switches |
SAN Director 64 (1 Gb) 32 ports, base model |
DS-DMGGD-BA
|
| SAN Director 64 Long-wave 4-port module kit |
DS-DMGGD-AC
|
|
| SAN Director 64 Short-wave 4-port module kit |
DS-DMGGD-AD
|
|
| SAN Director 64 Combo, Long 1 port/Short 3 ports - Wave Module Kit |
DS-DMGGD-AE
|
|
| SAN Edge Switch 2 Gb, 16 ports |
DS-DMGGE-BB
|
|
| SAN Edge Switch 2 Gb, 32 ports |
DS-DMGGE-BC
|
|
| SAN Director 2 Gb, 140 ports |
DS-DMGGD-CA
|
|
| SAN Edge Switch 2 Gb, 24 ports |
DS-DMGGE-BD
|
|
| 2-Gb SFF-SW Trncvr Kit |
3R-A2973-AA
|
|
| NOTE: Connection for, or between, 1-Gb and/or 2-Gb SAN switches require different cables. Refer to the Switches, Hubs, and Interconnects QuickSpecs at: http://www.compaq.com/products/quickspecs/north_america/10490.html | ||
|
|
||
|
Fibre Channel Cables |
NOTE: The following LC-SC connector cables support connectivity between 1-Gb and 2-Gb devices. | |
| 2-meter LC-SC multi-mode Fibre Channel cable |
3R-A2976-AA
|
|
| 5-meter LC-SC multi-mode Fibre Channel cable |
3R-A2977-AA
|
|
| 15-meter LC-SC multi-mode Fibre Channel cable |
3R-A2978-AA
|
|
| NOTE: The following LC-LC connector cables support connectivity between 2-Gb and 2-Gb devices. | ||
| 2-meter LC-LC multi-mode Fibre Channel cable |
3R-A2979-AA
|
|
| 5-meter LC-LC multi-mode Fibre Channel cable |
3R-A2980-AA
|
|
| 15-meter LC-LC multi-mode Fibre Channel cable |
3R-A2981-AA
|
|
|
|
||
|
Modular SAN Array 1000 (msa 1000) |
MSA1000 SAN Storage Array NOTE: Supported with DS-KGPSA-DA host bus adapter only; Tru64 UNIX requires V5.1B with Patch Kit: T64v51bb03as0001-20021229.tar; OpenVMS requires V7.3-1 with TIMA kit: VMS731_mSA1000-V0100 kit |
3R-A4328-AA
|
|
|
||
| Step 12 - Networks and Communications |
||
|
|
|
Step 12a - Networks and Communications - Mandatory |
||
|
|
||
|
||
|
|
||
| Maximum # Supported | ||||||||
| Tru64 UNIX | OpenVMS |
|
||||||
| Per Model 8 System |
Per Model 16 System |
Per External I/O Drawer | Per Model 8 System |
Per Model 16 System |
Per External I/O Drawer | Slot Type |
|
|
|
Ethernet Adapters
|
||||||||
|
PCI (32/64-bit, 33-MHz to 66-MHz) dual-port 10/100 Ethernet
(UTP/RJ45s) NIC and Base Module. (One 3X-DE602-TA or 3X-DE602-FA optional
add-on daughter card can be combined with this module.) Use BN25G, BN26M,
BN24Q, or BN28Q twisted pair RJ45 cables.
|
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DE602-BB
|
|
PCI-X/PCI Single-port 10/100/1000 Mbps (Twisted-Pair Copper
with RJ45) Gigabit Ethernet NIC. Use BN25G, BN26M, BN24Q, BN28Q, or equivalent
cables with RJ45 connectors.
NOTE: Only supported in PCI mode. Supported as a cluster interconnect under OpenVMS and Tru64 UNIX. OpenVMS remedial kit required: EV7 Tima: DEC-AXPVMS-VMS731 _EV7-V0100--4.PCSI LAN Tima: DEC-AXPVMS-VMS731 _LAN-V0100--4.PCSI |
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DEGXA-TA
|
|
|
|
Step 12b - Networks and Communications Optional |
||
|
|
||
| Maximum # Supported | ||||||||
| Tru64 UNIX | OpenVMS |
|
||||||
| Per Model 8 System |
Per Model 16 System |
Per External I/O Drawer | Per Model 8 System |
Per Model 16 System |
Per External I/O Drawer | Slot Type |
|
|
|
Ethernet Adapters
|
||||||||
|
Dual-port 10/100 Ethernet (UTP/RJ45) add-on daughter card
for use with the 3X-DE602-BB only. The combined 3X-DE602-BB and 3X-DE602-TA
modules provide four 10/100 (UTP/RJ45s) ports in a single PCI slot option.
OpenVMS remedial kit required: VMS731_LAN-V0100 Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. NOTE: 3X-DE602-TA cannot be used standalone. |
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DE602-TA
|
|
Single-port 100 Mbps (MMF/duplex-SC) add-on daughter card
for use with the 3X-DE602-BB. The combined 3X-DE602-BB and 3X-DE602-FA
provides two 10/100 (UTP/RJ45s) and one 100Mbps (MMF/SC) ports in a single
PCI slot option. Use BN34A or BN34B cables.
NOTE: 3X-DE602-FA cannot be used standalone. |
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DE602-FA
|
|
PCI-X/PCI Single-port 1000 Mbps (Fiber with duplex-SC)
Gigabit Ethernet NIC. Use BN34A, BN34B, or equivalent cables with SC connectors.
NOTES: Only supported in PCI mode. Supported as a cluster interconnect under OpenVMS and Tru64 UNIX. OpenVMS remedial kit required: EV7 Tima: DEC-AXPVMS-VMS731 _EV7-V0100- -4.PCSI LAN Tima: DEC-AXPVMS-VMS731 _LAN-V0100--4.PCSI Red Hat Linux V7.2 supported option, maximum one per system. |
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DEGXA-SA
|
|
|
|
FDDI Controllers
|
|
|||||||
|
PCI (32-bit, 33-MHz) to FDDI SAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables. |
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DEFPA-AC
|
|
PCI (32-bit, 33-MHz) to FDDI DAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables. |
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DEFPA-DC
|
|
PCI (32-bit, 33-MHz) to FDDI DAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DEFPA-MC
|
|
PCI (32-bit, 33-MHz) to FDDI SAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DEFPA-UC
|
|
Multimode fiber optic (MMF) 62.5/125um duplex cable with
SC-to-MIC connectors xx = available lengths:
(01, 03, and 10) for 1, 3, and 10 meters |
BN34D-xx
|
|
Synchronous/Asynchronous Controllers
|
|
|||||||
|
PCI (32-bit, 33-MHz) to Dual-port Intelligent Synchronous
Communications NIC Requires at least one (maximum two) BN34x sync
cable listed below
|
4 | 4 | 4 | 4 | 4 | 4 | 3.3V |
3X-PBXDD-AA
|
|
PCI (32-bit, 33-MHz) to Quad-port Intelligent Synchronous
Communications NIC Requires at least one (maximum four) BN34x sync
cable listed below.
|
4 | 4 | 4 | 4 | 4 | 4 | 3.3V |
3X-PBXDD-AB
|
|
Synchronous-specific Cables
|
|
|||||||
|
EIA-530 Single-port cable
|
3X-BC34G-06
|
|||||||
|
V.24/EIA-232 Single-port cable
|
3X-BC34L-06
|
|||||||
|
V.11/x.21 Single-port cable
|
3X-BC33S-06
|
|||||||
|
V.35 Single-port cable
|
3X-BC34T-06
|
|||||||
|
ATM Adapters
|
|
|||||||
|
PCI (32-bit, 33-MHz) to 155 Mbps ATM, Copper NIC with
RJ45 connector. Use BN25G-xx, or BN26M-xx cables.
|
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DAPBA-UA
|
|
PCI (32-bit, 33-MHz) to 155 Mbps ATM Fiber NIC with SC
connector. Use BN34B-xx cable.
|
8 | 8 | 8 | 8 | 8 | 8 | 3.3V |
3X-DAPBA-FA
|
|
|
||||||||
|
Asynchronous Communications
|
|
|||||||
|
PCI (32-bit, 33-MHz) to 4-port Async Communications NIC
with DB-25 octopus cable
|
2 | 2 | 2 | 2 | 2 | 2 | 3.3V |
PBXDA-BA
|
|
PCI (32-bit, 33-MHz) to 8-port Async Communications NIC
|
2 | 2 | 2 | 2 | 2 | 2 | 3.3V |
PBXDA-BB
|
|
PCI (32-bit, 33-MHz) to 16-port Async Communications Controller
and rackmount 16-port distribution box with RJ45 connectors
|
2 | 2 | 2 | 2 | 2 | 2 | 3.3V |
PBXDA-AC
|
|
Asynchronous Connector Adapters
|
|
|||||||
|
RJ45-to-DB-25 Converter Cable
|
CXI01-AC
|
|||||||
|
RJ45-to-DEC MJ11 Converter Cable
(8 pack) |
CXI01-AF
|
|
Ethernet, FDDI, ATM Cables
|
|
|||||||
| Multimode fiber optic (MMF)
62.5/125um duplex cable, with SC-to-ST connectors. xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters |
BN34A-xx
|
|||||||
| Multimode fiber optic (MMF)
62.5/125um duplex cable, with SC-to-SC connectors. xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters |
BN34B-xx
|
|||||||
| Category 5e (4-Unshielded Twisted
Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for system
to switch, repeater, or hub connectivity. xx = available lengths: (0B, 0E, 01, 03, 04, 07) for 0.2, 0.5, 1, 3, 4, and 7 meters |
BN25G-xx
|
|||||||
| Category 5e (4-Twisted Pairs,
Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for
system to switch, repeater, or hub connectivity. xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters |
BN26M-xx
|
|||||||
| Category 5e (4-Unshielded Twisted
Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to switch,
repeater, or hub connectivity. xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters |
BN24Q-xx
|
|||||||
| Category 5e (4-Twisted Pairs,
Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to
switch, repeater, or hub connectivity. xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters |
BN28Q-xx
|
|
|
|
|
||
|
|
||
| Maximum # Supported | ||||||||
| Tru64 UNIX | OpenVMS |
|
||||||
| Per Model 8 System |
Per Model 16 System |
Per External I/O Drawer |
Per Model 8 System |
Per Model 16 System |
Per External I/O Drawer |
Slot Type |
|
|
|
ATI RADEON 7500 2D AGP graphics accelerator
|
4 | 4 | 4 | 1 | 1 | 1 | AGP(1) |
3X-PBXGG-AB
|
|
ATI RADEON 7500 2D PCI graphics accelerator
|
4 | 4 | 4 | 1 | 1 | 1 | 3.3V PCI |
3X-PBXGG-AA
|
|
Tru64 UNIX Open3D license for RADEON7500 (required for
3D functionality)
|
QL-6ZRA9-AA
|
|||||||
|
OpenVMS Open3D license for RADEON 7500 (required for 3D
functionality)
|
QL-0ADA9-AA
|
|||||||
|
Additional Tru64 UNIX media kit for RADEON 7500 (initial
kit ships with RADEON card)
|
QA-6ZRAA-H8
|
|||||||
|
Additional OpenVMS media kit for RADEON 7500 (initial
kit ships with RADEON card)
|
QA-6ZPAA-H8
|
|||||||
| (1) Only supported in 2X mode | ||||||||
|
NOTE : Maximum graphics adapters per system, all types - Tru64 UNIX 4, OpenVMS 1 |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Tru64 UNIX (V5.1B) |
|
|
|
|
||
| OpenVMS (V7.3-1) |
|
|
|
|
||
|
MEMORY CHANNEL Controller
|
PCI-to-System Area Network Controller,
maximum two - 5.0V/3.3V compatible |
CCMAB-BA
|
| System Area Network Hub with four
line cards; includes BN19P-2E power cord for Canada, Japan, and U.S. For
other regions, order appropriate power cord from list that follows. |
CCMHB-AA
|
|
| Hub expansion box with no line
cards |
CCMHB-BA
|
|
| Expansion line card for CCMHB
hub |
CCMLB-AA
|
|
| 1-meter cable for CCMAB and CCMHB |
BN39B-01
|
|
| 4-meter cable for CCMAB and CCMHB |
BN39B-04
|
|
| 10-meter cable for CCMAB and CCMHB |
BN39B-10
|
|
| Copper-to-single mode fiber optic
converter - 5.0V/3.3V compatible |
CCMFB-BA
|
|
| Rackmount kit (3U) for CCMHB (Memory
Channel Hub II); required for mounting in H9A40/H9A45 Cabinets. |
3X-BA61R-MD
|
|
| Power cord for rackmount CCMHB hub |
BN35S-02
|
|
|
|
||
| Country-specific
Power Cords for Standalone MEMORY CHANNEL Hubs |
Australia, New Zealand |
BN19H-2E
|
| Central Europe |
BN19C-2E
|
|
| Denmark |
BN19K-2E
|
|
| Egypt, India |
BN19S-2E
|
|
| Ireland, United Kingdom |
BN19A-2E
|
|
| Israel |
BN18L-2E
|
|
| Italy |
BN19M-2E
|
|
| Japan, 2.5-meter, Dentori approved |
3X-BN46F-02
|
|
| Switzerland |
BN19E-2E
|
|
| NOTE: When using
MEMORY CHANNEL, refer to the TruCluster QuickSpecs for configuration guidelines
and restrictions: http://www.compaq.com/products/quickspecs/division/10657.html The MEMORY CHANNEL controller, CCMAB-AA, must be revision D02 or later. |
||
|
|
||
|
|
||
|
|
||
| Keyboard, Mouse, and Video Extension Cable Kit |
Two 6-foot/1.8-meter USB keyboard/mouse extension cables and one 6-foot/1.8-meter video extension cable (one per system) |
CK-GSKVM-AA
|
|
|
||
| Video Extension Cable | 6-foot/1.8-meter video extension cable |
BN39C-02
|
|
|
||
| Mouse | 3-button mouse - USB |
3X-PBQWS-WB
|
|
|
||
| Monitors |
|
|
|
|
||
| Carbon/Silver Monitors | V7550 17-inch (16-inch viewable image size) flat-faced shadow mask color monitor, two-tone (carbon/silver), 0.25mm dot pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO99/ Energy Star compliant, Northern Hemisphere with North America power cord, VGA cable |
3R-A4002-AA
|
| Same as above, with Euro power cord |
3R-A4201-AA
|
|
| Same as above, APD, no power cord |
3R-A4202-AA
|
|
| Same as above, Southern Hemisphere, with Australia/New Zealand power cord |
3R-A4203-AA
|
|
| S7500 17-inch (16-inch viewable image size) FST multi-frequency color monitor, 2-tone (carbon/silver), 0.24-mm dot pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with PRC power cord CCIB, VGA cable |
3R-A4800-AA
|
|
| P930 19-inch (18-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24-mm aperture grille pitch, VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable |
3R-A4215-AA
|
|
| Same as above, with Euro power cord |
3R-A4391-AA
|
|
| Same as above, Taiwan, with North America power cord |
3R-A4392-AA
|
|
| Same as above, Southern Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord |
3R-A4393-AA
|
|
| S9500 19-inch (18-inch viewable image size) FST multi-frequency color monitor, 2-tone (carbon/silver), 0.24-mm dot pitch, VGA to 1280 x 1024 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with PRC power cord CCIB, VGA cable |
3R-A4801-AA
|
|
| P1130 21-inch (19.8-inch viewable image size) FD Trinitron auto-scanning color monitor, 0.24-mm aperture grille pitch, VGA to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable |
3R-A4216-AA
|
|
| Same as above, with Euro power cord |
3R-A4396-AA
|
|
| Same as above, Taiwan, North America power cord |
3R-A4397-AA
|
|
| Same as above, with PRC power cord, CCIB |
3R-A4400-AA
|
|
| Same as above, Southern Hemisphere, with Australia/New Zealand power cord |
3R-A4398-AA
|
|
|
|
||
| Carbon/Silver Flat Panel Monitors | TFT1825, 18-inch (18-inch viewable image size) TFT flat panel monitor, 0.28mm pixel pitch, 1600 x 1200 @60Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, one VGA, one DVI-I input connector. North America power cord, VGA and DVI-I cables |
3R-A4292-AA
|
| L1530, 15-inch (15-inch viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @60 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA and one DVI-I), North America power cord, VGA and DVI-I cables |
3R-A4857-AA
|
|
| L1530, 15-inch (15inch viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @60 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA and one DVI-I), Euro power cord, VGA and DVI-I cables |
3R-A4858-AA
|
|
|
|
||
| Monitor Power Cords | North America, 120V, 75-inch |
BN26J-1K
|
| Australia, New Zealand, 2.5-meter |
BN19H-2E
|
|
| Central Europe, 2.5-meter |
BN19C-2E
|
|
| Denmark, 2.5-meter |
BN19K-2E
|
|
| Egypt, India, South Africa, 2.5-meter |
BN19S-2E
|
|
| Israel, 2.5-meter |
BN18L-2E
|
|
| Italy, 2.5-meter |
BN19M-2E
|
|
| Japan, 2.5-meter, Dentori approved |
3X-BN46F-02
|
|
| Switzerland, 2.5-meter |
BN19E-2E
|
|
| UK, Ireland, 2.5-meter |
BN19A-2E
|
|
|
|
||
|
Keyboards - USB Keyboard/Language
|
Tru64 UNIX
|
OpenVMS
|
|
U.S./English/International keyboard
|
3R-LKQ50-BA
|
3X-LK463-A2
|
|
Arabic keyboard
|
3R-LKQ50-BR
|
-
|
|
Belgian keyboard
|
3R-LKQ50-AB
|
3X-LK463-AB
|
|
BHCSY keyboard
|
3R-LKQ50-AX
|
-
|
|
Canadian/English keyboard
|
-
|
3X-LK463-AQ
|
|
Canadian/French keyboard
|
3R-LKQ50-AC
|
3X-LK463-AC
|
|
Cyrillic keyboard (Russian)
|
3R-LKQ50-BT
|
3X-LK463-BT
|
|
Czech keyboard
|
3R-LKQ50-BV
|
3X-LK463-BV
|
|
Danish keyboard
|
3R-LKQ50-AD
|
3X-LK463-AD
|
|
Dutch keyboard
|
3R-LKQ50-AH
|
3X-LK463-AH
|
|
Finnish keyboard
|
3R-A4590-AA
|
3X-LK463-AF
|
|
French keyboard
|
3R-LKQ50-AP
|
3X-LK463-AP
|
|
German keyboard
|
3R-LKQ50-AG
|
3X-LK463-AG
|
|
Greek keyboard
|
3R-LKQ50-BH
|
3X-LK463-BH
|
|
Hebrew keyboard
|
3R-LKQ50-AT
|
3X-LK463-AT
|
|
Hungarian keyboard
|
3R-LKQ50-BQ
|
3X-LK463-BQ
|
|
Italian keyboard
|
3R-LKQ50-AI
|
3X-LK463-AI
|
|
Japanese keyboard
|
3R-LKQ50-AJ
|
-
|
|
Korean keyboard
|
3R-LKQ50-BK
|
-
|
|
Latin-American keyboard
|
3R-LKQ50-AR
|
-
|
|
Norwegian keyboard
|
3R-LKQ50-AN
|
3X-LK463-AN
|
|
Polish keyboard
|
3R-LKQ50-BP
|
3X-LK463-BP
|
|
Portuguese keyboard
|
3R-LKQ50-AV
|
3X-LK463-AV
|
|
Romanian keyboard
|
-
|
3X-LK463-BL
|
|
Simplified Chinese keyboard
|
3R-LKQ50-CV
|
-
|
|
Spanish keyboard
|
3R-LKQ50-AS
|
3X-LK463-AS
|
|
Swedish keyboard
|
3R-LKQ50-AM
|
3X-LK463-AM
|
|
Swiss/French keyboard
|
3R-LKQ50-AK
|
3X-LK463-AK
|
|
Swiss/German keyboard
|
-
|
3X-LK463-AL
|
|
Traditional Chinese keyboard
|
3R-LKQ50-BI
|
-
|
|
Thai keyboard
|
3R-LKQ50-CB
|
-
|
|
Turkish keyboard
|
3R-LKQ50-BU
|
3X-LK463-BU
|
|
Turkish/F keyboard
|
-
|
3X-LK463-BW
|
| UK keyboard | 3R-LKQ50-AE | - |
|
Yugoslavian keyboard
|
-
|
3X-LK463-BY
|
|
|
| Rackmount Keyboard/Drawer and Keyboard/Monitor Options |
PS2 to USB Converter allows for connection of a PS2 keyboard and/or mouse to an AlphaServer ES47 System |
3R-A4495-AA
|
| HP Rackmount Flat Panel Monitor |
3R-A4220-AA
|
|
| Integrated Keyboard and Drawer | ||
| Integrated Keyboard and Drawer (1U), North America |
3R-A4404-AA
|
|
| Integrated Keyboard and Drawer (1U), International |
3R-A4405-AA
|
|
| Integrated Keyboard and Monitor (TFT5600RKM) | ||
| Integrated Keyboard and Monitor, North America |
3R-A3496-AA
|
|
| Integrated Keyboard and Monitor, France |
3R-A3709-AA
|
|
| Integrated Keyboard and Monitor, Germany |
3R-A3708-AA
|
|
| Integrated Keyboard and Monitor, International |
3R-A3498-AA
|
|
| Integrated Keyboard and Monitor, Spain |
3R-A3710-AA
|
|
| Integrated Keyboard and Monitor, United Kingdom |
3R-A3706-AA
|
|
| NOTE: Integrated Keyboard and Drawer and Integrated Keyboard and Monitor require one Keyboard and Mouse Adapter for USB (3R-A4495-AA) | ||
|
|
||
|
|
||
|
|
||
| Tru64 UNIX |
|
|
| Tru64 UNIX media and online documentation on CD-ROM |
QA-6ADAA-H8
|
|
| Tru64 UNIX full hard copy documentation |
QA-6ADAA-GZ
|
|
| TruCluster Plus Software Package with licenses for TruCluster Server, Logical Storage Manager and AdvFS Utilities |
QP-6R9AQ-AA
|
|
| TruCluster Server license |
QL-6BRAQ-AA
|
|
| Logical Storage Manager license |
QL-2GVAQ-AA
|
|
| AdvFS Utilities license |
QL-0EGAQ-AA
|
|
| Advanced Server for Tru64 UNIX, 25 client concurrent use license |
QL-5U29M-3D
|
|
| Advanced Server for Tru64 UNIX, 50 client concurrent use license |
QL-5U29M-3E
|
|
| Advanced Server for Tru64 UNIX, 100 client concurrent use license |
QL-5U29M-3F
|
|
| Advanced Server for Tru64 UNIX, 250 client concurrent use license |
QL-5U29M-3G
|
|
| Advanced Server for Tru64 UNIX, 500 client concurrent use license |
QL-5U29M-3H
|
|
| Layered products media and documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8
|
|
| DECnet/OSI end-system function license for Tru64 UNIX |
QL-MTJAQ-AA
|
|
| DECnet/OSI extended license for Tru64 UNIX |
QL-MTKAQ-AA
|
|
|
|
||
| OpenVMS |
|
|
| Concurrent Use 1-user license |
QL-MT3AA-3B
|
|
| Concurrent Use 2-user license |
QL-MT3AA-3C
|
|
| Concurrent Use 4-user license |
QL-MT3AA-3D
|
|
| Concurrent Use 8-user license |
QL-MT3AA-3E
|
|
| Concurrent Use 16-user license |
QL-MT3AA-3F
|
|
| Concurrent Use 32-user license |
QL-MT3AA-3G
|
|
| Concurrent Use 64-user license |
QL-MT3AA-3H
|
|
| Concurrent Use 128-user license |
QL-MT3AA-3J
|
|
| Concurrent Use 256-user license |
QL-MT3AA-3K
|
|
| Traditional unlimited-user license |
QL-MT2AQ-AA
|
|
| OpenVMS media and online documentation on CD-ROM |
QA-MT1AA-H8
|
|
| OpenVMS hard copy documentation |
QA-001AA-GZ
|
|
| OpenVMS base hard copy documentation |
QA-09SAA-GZ
|
|
| OpenVMS Alpha Software Products Library Package: Layered products media and documentation for OpenVMS on CD-ROM, includes media and documentation for all products licensed in the Enterprise Integration Package. |
QA-03XAA-H8
|
|
| DECnet-Plus/DECnet end-system license |
QL-MTFAQ-AA
|
|
| DECnet-Plus/DECnet extended-function license |
QL-MTHAQ-AA
|
|
| Cluster License for OpenVMS Alpha |
QL-MUZAQ-AA
|
|
| OpenVMS Volume shadowing license |
QL-2A1AQ-AA
|
|
| A more complete software list can be found at: http://www.openvms.compaq.com/swcat/index.html | ||
|
|
||
| OpenVMS Galaxy Licensing Requirements | For more details about OpenVMS Galaxy licensing requirements, refer to Software Product Description for the Galaxy Software Architecture on OpenVMS Alpha, SPD 70.44.xx | |
|
||
| Maximum instances per system or hard partition for GS1280: | ||
| Model 8 | Model 16 | Model 32 | Model 64 | ||
| CPUs |
8
|
16
|
32
|
32 x 2 hard partitions |
|
| Instances |
2
|
4
|
8
|
8 x 2 hard partitions |
|
| I/O Master Drawers |
2
|
4
|
8
|
8 x 2 hard partitions |
| For more information about OpenVMS Galaxy requirements, configurations, and procedures, refer to the OpenVMS Alpha Galaxy Guide. The latest version is always available at http://h71000.www7.hp.com/availability/AA-REZQE-TE.pdf | ||
| Galaxy 1-CPU License |
QL-66XAA-3B
|
|
| Galaxy 2-CPU License |
QL-66XAA-3C
|
|
| Galaxy 4-CPU License |
QL-66XAA-3D
|
|
| Galaxy 8-CPU License |
QL-66XAA-3E
|
|
| Galaxy 16-CPU License |
QL-66XAA-3F
|
|
| Example: 24-CPU GS1280 system in which all processors are licensed for OpenVMS with two hard partitions (one 8-CPU SMP and one 16-CPU Galaxy) | ||
|
||
|
|
||
|
|
|
|
|
|
|
| HP Care Pack Services |
|
|
|
|
||
| Program Features Principal Server | ||
| HP Support Plus |
|
|
|
|
||
| HP Support Plus 24 |
|
|
|
|
||
| Program Features Additional Services | ||
| SSPs (Subsequent System Packages) |
|
|
|
|
||
| Installation |
|
|
|
|
||
| Installation and Startup HP O/S |
|
|
|
|
||
| Model/HP Care Pack Services |
Principal Server 1 year |
Principal Server 3 years |
Subsequent Systems 1 year |
Subsequent Systems 3 years |
|
AlphaServer GS1280 Model 8
|
||||
|
HP Support Plus
|
FP-W01BA-12
|
FP-W01BA-36
|
FP-W21BA-12
|
FP-W21BA-36
|
|
HP Support Plus 24
|
FP-W02BA-12
|
FP-W02BA-36
|
FP-W22BA-12
|
FP-W22BA-36
|
|
Installation
|
FP-WINST-BA
|
FP-WINST-BA
|
FP-WINST-BA
|
FP-WINST-BA
|
|
Installation and Startup
|
FP-WSTAR-BA
|
FP-WSTAR-BA
|
FP-WSTAR-BA
|
FP-WSTAR-BA
|
|
|
|
|
|
|
|
AlphaServer GS1280 Model 16
|
|
|
|
|
|
HP Support Plus
|
FP-W01BB-12
|
FP-W01BB-36
|
FP-W21BB-12
|
FP-W21BB-36
|
|
HP Support Plus 24
|
FP-W02BB-12
|
FP-W02BB-36
|
FP-W22BB-12
|
FP-W22BB-36
|
|
Installation
|
FP-WINST-BB
|
FP-WINST-BB
|
FP-WINST-BB
|
FP-WINST-BB
|
|
Installation and Startup
|
FP-WSTAR-BB
|
FP-WSTAR-BB
|
FP-WSTAR-BB
|
FP-WSTAR-BB
|
|
|
|
NOTES:
|
|
|
| Recommended Factory Integration Services for GS1280 Systems |
Value-added Implementation Services (VIS) provides systems integration
and delivery services. VIS services, including system integration, extended
burn-in, custom documentation, and on-site services can be custom-quoted
for the full range of AlphaServer configurations. These pre-packaged services
are offered for systems shipped to North America and Japan. For similar
services in Europe, e-mail specific requirements to: customsystems.europe@hp.com
For similar services in Asia/Pacific, |
|
Pre-packaged VIS services are
recommended for popular AlphaServer GS1280 system configurations that include
up to one storage array:
|
||
|
|
||
| Basic Integration Service | Systems integration and delivery services related to the configuration of the first and/or only instance of an operating system on a single AlphaServer GS1280 building block. Includes the following: |
YT-VISIT-B1
|
|
||
|
|
||
| Extra RAID Pair Service | Configuration of additional Intelligent RAID controller pairs beyond the internal and external RAID controller pairs included within the scope of the prerequisite YT-VISIT-B1 on the same single AlphaServer GS1280 platform. The following services are included in the optional YT-VISIT-R1 Extra RAID Pair Service per each additional pair of Intelligent RAID controllers configured: |
YT-VISIT-R1
|
|
||
|
|
||
| Clustering Service | Configuration of a single cluster instance for AlphaServer GS1280 platforms. This is a per-cluster service and is ordered along with the prerequisite YT-VISIT-B1 services. |
YT-VISIT-C1
|
|
||
|
|
||
| Partitioning Service | Configuration of multiple, non-clustered instances of a second or subsequent operating system on a single AlphaServer GS1280 platform. This is a per-partition service and is ordered along with the prerequisite YT-VISIT-B1 services. The first instance of an operating system is included in the YT-VISIT-B1 service, subsequent partitions require the YT-VISIT-P1 partitioning service. |
YT-VISIT-P1
|
|
||
|
|
||
| Full Custom Configurations | The Integration Service Packages address the most-common customer requirements. For a wider range of configurations, customers can also choose additional customized services based upon a Statement of Work agreement. This includes: cluster add-on nodes, larger storage configurations, custom option support, custom system packaging, mixed operating system partitions, and configured multi-system clusters. Contact your local sales representative for these services. |
|
|
Upgrades
|
Step 18 - AlphaServer GS1280 System Hardware Upgrade |
|
|
|
|
|
| GS1280 Model 8 to Model 16 Upgrade Kits | System expansion hardware to upgrade
an AlphaServer GS1280 Model 8 to an AlphaServer GS1280 Model 16. Includes
one System Building Block Drawer with one power shelf with three power supplies;
one rackmount slide kit; and associated inter-processor cabling. NOTE: Requires the purchase of one PDU see Step 7. |
3X-BA65B-AA
|
| System expansion hardware to upgrade two AlphaServer GS1280 Model 8 systems to an AlphaServer GS1280 Model 16 system. |
3X-BNPSB-02
|
|
|
|
||
|
HP Care Pack Services for Expansion from GS1280 Model
8 to Model 16
|
||||
| Model/HP Care Pack Priority Service |
Principal Server 1 year |
Principal Server 3 years |
Subsequent Systems 1 year |
Subsequent Systems 3 years |
|
AlphaServer GS1280 Model 8P Expansion
|
||||
|
HP Support Plus
|
FP-W01BA-12
|
FP-W01BA-36
|
FP-W21BA-12
|
FP-W21BA-36
|
|
HP Support Plus 24
|
FP-W02BA-12
|
FP-W02BA-36
|
FP-W22BA-12
|
FP-W22BA-36
|
|
Installation
|
FP-WINST-BU
|
FP-WINST-BU
|
FP-WINST-BU
|
FP-WINST-BU
|
|
Installation and Startup
|
FP-WSTAR-BU
|
FP-WSTAR-BU
|
FP-WSTAR-BU
|
FP-WSTAR-BU
|
|
|
TechSpecs
| AlphaServer GS1280 Model 8 | North America | Japan | Europe |
| Power Requirements | |||
| Voltage |
120/208 |
200 |
380/415 |
| Phase/Frequency | 3W+G, 50-60 Hz |
3W+G, 50-60 Hz |
3W+N+G, 50-60 Hz |
| KVA, Model 8, 2 I/O Drawers, 4 SW Shelves | 6.083 | 6.083 | 6.083 |
| Power Plug, 1 required; 2 for dual AC |
L21-30P, Hubbell 2811 | L21-30P, Hubbell 2811 | IEC 32A, Hubbell 532P6W |
| PDU, 1 required; 2 for dual AC |
3X-H7606-AA |
3X-H7606-AA |
3X-H7606-AB |
| Rated Current, each PDU |
24A |
24A |
24A |
| Typical Current, each PDU |
18.5A |
19A |
10A |
| Internal Power Outlets |
3 x C19, 24 x C13 |
3 x C19, 24 x C13 |
3 x C19, 24 x C13 |
| Line Connection |
fixed cord & plug |
fixed cord & plug |
fixed cord & plug |
| Power Cord |
5 x 10AWG |
5 x 10AWG |
5 x 4 mm2 |
| Power Plug |
L21-30P, Hubbell 2811 |
L21-30P, Hubbell 2811 |
IEC 32A, Hubbell 532P6W |
| Main Breaker |
30A |
30A |
30A |
| Sub-breakers |
3 x 20A(2p), 1 x 20A(3p) |
3 x 20A(2p), 1 x 20A(3p) |
3 x 15A(2p), 1 x 15A(3p) |
| Agency | UL Listed, cUL | UL Listed, cUL | TUV & CB report |
| Physical Characteristics | |||
| Dimensions (H x W x D) | 79 x 24 x 47 in (200 x 60 120 cm) | 79 x 24 x 47 in (200 x 60 120 cm) | 79 x 24 x 47 in (200 x 60 120 cm) |
| Shipping dimensions (H x W x D) |
85 x 36 x 56 in (217 x 92.5 142 cm) | 85 x 36 x 56 in (217 x 92.5 142 cm) | 85 x 36 x 56 in (217 x 92.5 142 cm) |
| Service Clearance | |||
| Front | 39.4 in (100cm) | 39.4 in (100cm) | 39.4 in (100cm) |
| Sides | 0 | 0 | 0 |
| Rear | 31.5 in (80cm) | 31.5 in (80cm) | 31.5 in (80cm) |
| Installed Weight | 1,240 lb (563 kg) | 1,240 lb (563 kg) | 1,240 lb (563 kg) |
| Heat Dissipation (Watts/Btu/hr) | |||
| Max Heat Output, Model 8 only, watts | 3,405 | 3,405 | 3,405 |
| Max heat Output, Model 8 only, Btu/hr | 11,622 | 11,622 | 11,622 |
| Typical Heat Output, Model 8 only, watts | 2,430 | 2,430 | 2,430 |
| Typical Heat Output, Model 8 only, Btu/hr | 8,297 | 8,297 | 8,297 |
| Max Heat Output, Full Rack | 6,405 | 6,405 | 6,405 |
| Max Heat Output, Full Rack, Btu/hr | 21,861 | 21,861 | 21,861 |
| Typical Heat Output, Full Rack, w | 3,330 | 3,330 | 3,330 |
| Typical Heat Output, Full Rack, Btu/hr | 11,366 | 11,366 | 11,366 |
| Airflow, cfm, minimum full rack | 850 | 850 | 850 |
| Airflow, cfm, maximum full rack | 1,210 | 1,210 | 1,210 |
| Environmental | Operating | Non-operating | |
| Temperature | 41 to 95° F (10 to 35° C) | -40 to 151° F (-40° to 66° C) | |
| Relative Humidity (non-condensing) | 10 to 90% | 10 to 95% | |
| Maximum Altitude | 10,000 ft (3,050 m) | 40,000 ft (12,200 m) | |
| Shock | 5G 30ms, half sine | ||
| Acoustics (Declared values per ISO 9296 and ISO 7779) |
Idle/Operating | (Bystander pos.) | |
| Part | Description | LwAd, B | LpAm, dBA |
| GS1280 Model 8 | GS1280 Model 8 + 1 I/O Master Drawer | 7.4 | 55 |
| GS1280 System Building Block | 1 x 8P System Drawer | 6.8 | 50 |
| Power shelf with 3 PSU | 6.7 | 48 | |
| 3X-BA70A-BA | I/O Expansion Drawer | 7.1 | 51 |
| DS-SL13R-xx | StorageWorks Shelf | 6.9 | 53 |
| NOTE: Current values for specific configurations are available. 1 B = 10 dBA | |||
|
|
|||
| AlphaServer GS1280 Model 16 | North America | Japan | Europe |
| Power Requirements | |||
| Voltage |
120/208 |
200 |
380/415 |
| Phase/Frequency |
3W+G, 50-60 Hz |
3W+G, 50-60 Hz |
3W+N+G, 50-60 Hz |
| KVA, Model 16, 2 I/O Drawers, 4 SW Shelves | 12 |
12 | 12 |
| Power Plug, 2 required; 4 for dual AC |
L21-30P, Hubbell 2811 |
L21-30P, Hubbell 2811 | IEC 32A, Hubbell 532P6W |
| PDU, 2 required; 4 for dual
AC |
3X-H7606-AA |
3X-H7606-AA | 3X-H7606-AB |
| Rated Current, each PDU |
24A |
24A |
24A |
| Typical Current, each PDU |
18.5A |
19A |
10A |
| Internal Power Outlets |
3 x C19, 24 x C13 |
3 x C19, 24 x C13 |
3 x C19, 24 x C13 |
| Line Connection |
fixed cord & plug |
fixed cord & plug |
fixed cord & plug |
| Power Cord |
5 x 10AWG |
5 x 10AWG |
5 x 4 mm2 |
| Power Plug |
L21-30P, Hubbell 2811 |
L21-30P, Hubbell 2811 |
IEC 32A, Hubbell 532P6W |
| Main Breaker |
30A |
30A |
30A |
| Sub-breakers |
3 x 20A(2p), 1 x 20A(3p) |
3 x 20A(2p), 1 x 20A(3p) |
3 x 15A(2p), 1 x 15A(3p) |
| Agency | UL Listed, cUL | UL Listed, cUL | TUV & CB report |
| Physical Characteristics | |||
| Dimensions (H x W x D) | 79 x 24 x 47 in (200 x 60 120 cm) | 79 x 24 x 47 in (200 x 60 120 cm) | 79 x 24 x 47 in (200 x 60 120 cm) |
| Shipping dimensions (H x W x D) | 85 x 36 x 56 in (217 x 92.5 142 cm) | 85 x 36 x 56 in (217 x 92.5 142 cm) | 85 x 36 x 56 in (217 x 92.5 142 cm) |
| Service Clearance | |||
| Front | 39.4 in (100cm) | 39.4 in (100cm) | 39.4 in (100cm) |
| Sides | 0 | 0 | 0 |
| Rear | 31.5 in (80cm) | 31.5 in (80cm) | 31.5 in (80cm) |
| Installed Weight | 1,310 lb (594 kg) | 1,310 lb (594 kg) | 1,310 lb (594 kg) |
| Heat Dissipation (Watts/Btu/hr) | |||
| Max Heat Output, Model 16 only, watts | 6,810 | 6,810 | 6,810 |
| Max heat Output, Model 16 only, Btu/hr | 23,243 | 23,243 | 23,243 |
| Typical Heat Output, Model 16 only, watts | 3,700 | 3,700 | 3,700 |
| Typical Heat Output, Model 16 only, Btu/hr | 12,632 | 12,632 | 12,632 |
| Airflow, cfm, minimum full rack | 1,500 | 1,500 | 1,500 |
| Airflow, cfm, maximum full rack | 2,200 | 2,200 | 2,200 |
| Environmental | Operating | Non-operating | |
| Temperature | 41 to 95° F (10 to 35° C) | -40 to 151° F (-40° to 66° C) | |
| Relative Humidity (non-condensing) | 10 to 90% | 10 to 95% | |
| Maximum Altitude | 10,000 ft (3,050 m) | 40,000 ft (12,200 m) | |
| Shock | 5G 30ms, half sine | ||
| Acoustics (Declared values per ISO 9296 and ISO 7779) |
Idle/Operating | (Bystander pos.) | |
| Part | Description | LwAd, B | LpAm, dBA |
| GS1280 Model 16 | GS1280 Model 16 + 1 I/O Master Drawer | 7.6 | 57 |
| 3X-BA70A-BA | I/O Expansion Drawer | 7.1 | 51 |
| DS-SL13R-xx | StorageWorks Shelf | 6.9 | 53 |
| NOTE: Current values for specific configurations are available. 1 B = 10 dBA | |||
|
|
|||
| © Copyright 2004 Hewlett-Packard
Development Company, L.P. The information contained herein is subject to change without notice. UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |