Overview
|
HP ProLiant BL40p Server Blade
|
What's New
HP ProLiant BL40p Server Blade includes:
|
|
What's Needed HP BladeSystem p-Class Server Blade Enclosure:
HP BladeSystem p-Class Power Enclosures:
HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
|
|
|
|
||||||||||||||||||||||||
|
|
|||||||||||||||
|
Configuration Steps For a complete configuration of the HP ProLiant BL40p server blade, do the following:
|
|
|
Standard Features (Server Blade)
| HP ProLiant BL40p Server Blade | |
| Processor One of the following depending on Model: |
Xeon MP processor 3.0 GHz/4MB |
| Xeon MP processor 2.2 GHz/2MB | |
|
|
|
| Upgradeability | Upgradeable to quad processing |
|
|
|
| Cache Memory | 4-MB Level 3 Cache (on the 3.0GHz Model) |
| 2-MB Level 3 Cache (on the 2.2GHz Models) | |
|
|
|
| Chipset | ServerWorks GC-LE
chipset NOTE: For more information regarding ServerWorks, please see the following URL: http://www.serverworks.com/products/overview.html. |
|
|
|
| Memory Protection | Advanced Memory Protection with Online Spare |
|
|
|
| Memory | Type |
2-way interleaved PC2100 ECC DDR | (2 X 256 MB) |
| Standard |
512MB (1 processor model) |
||
| Maximum |
12,288 MB |
(2 X 512MB) | |
| Standard |
1024MB (2 processor model) |
||
| Maximum | 12,288 MB | ||
| NOTE: Memory must be installed in pairs. Advanced Memory Protection with Online Spare. | |||
|
|
|||
| Network Controller | Six network adapters total: |
| Five NC7781 PCI-X Gigabit NICs (embedded) with WOL and PXE | |
| One 10/100T iLO NIC dedicated to management | |
|
| |
| Manageability | Integrated Lights-Out (iLO) Management Advanced (ASIC on the System Board) |
|
|
|
| Internal Storage | Hard Drives | None ship standard | |
| Maximum Internal Storage |
SCSI | 1200 GB (internal drive cage) | (4 x 300 GB) |
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. | |||
|
|
|||
| Expansion Slots | Two Dedicated PCI-X slots (64b/100MHz capable) for redundant SAN connectivity |
| I/O cable | I/O cable connectors: |
| (2)USB ports, (1) video port, (1) iLO port and (1) kernel debug port | |
| (2) I/O cables ship with every server blade enclosure | |
| Tested USB devices (keyboard, mouse, floppy) are listed in options section of this QuickSpecs | |
|
|
|
| Dimensions | 6U high x 7" wide. Fits within p-Class Server Blade Enclosure. One HP ProLiant BL40p server blade takes up four (4) server blade bays within a server blade enclosure. Two HP ProLiant BL40p server blades can fit within one server blade enclosure. |
|
|
Standard Features (Server Blade Enclosure and Interconnects)
| HP BladeSystem p-Class Server Blade Enclosure and ProLiant BL p-Class Interconnects | |
| HP BladeSystem p-Class Server Blade Enclosure |
6U (10.5-inch), 19-inch wide
Server blades slide in and connect to the server blade enclosure back
plane for power and data connections |
|
|
|
| HP BladeSystem p-Class Power Requirements | Redundant 200V - 240V AC, 30
amp single-phase Redundant 208V 30amp 3-phase 4 wire Redundant -48VDC ± 10% |
|
|
|
| HP ProLiant BL p-Class Interconnect
Switch Option (Two switches per kit) (Every HP BladeSystem p-Class server blade enclosure requires two interconnect switches OR two RJ-45 patch panels) |
Provides up to a 32 to 1 server networking cable reduction per server enclosure depending on the mix of HP ProLiant BL20p, HP ProLiant BL20p G2, and HP ProLiant BL40p server blades. Each interconnect switch (two per enclosure) reduces up to sixteen internal server network (NICs) ports to six external ports (four on a modular rear mounting interconnect module and two on the switch front panel). This provides a total of twelve external ports per server blade enclosure. Only one to all twelve external ports may be used per server blade enclosure. The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kit is
for applications that require network adapter consolidation to 1000 Mbps
(Gigabit Ethernet) in a Cisco infrastructure. The CGESM supports the same
HP ProLiant BL40p G2 Fibre Channel pass-through as the GbE2.
Also included (per Interconnect Switch):
Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support, and more. |
|
|
|
| HP ProLiant BL p-Class RJ-45 patch panel |
6U (10.5-inch), Plugs into BL p-Class 6U server blade enclosures |
| (Two patch panels per kit) (Every HP BladeSystem p-Class server blade enclosure requires two interconnect switches OR two RJ-45 patch panels) |
|
|
|
|
| Required Network Cabling | 10Base-T |
Categories 3, 4 or 5 UTP (100
meters) EIA/TIA-568 100-ohm STP (100 meters) |
| 100Base-TX | Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) | |
| 1000Base-T | Category
5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) | |
| 1000Base-SX | 50/125
µm Multimode Fiber, 400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters) 62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters) 62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters) |
|
|
Standard Features (Power System and Rack Information)
| HP BladeSystem p-Class Power System and Rack information | NOTE:
To determine power configuration please refer to the ProLiant BL p-Class Overview
and Planning Whitepaper and sizing tool, please see the following URL: http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/20p/index.html |
| | |
| HP BladeSystem p-Class 3U Power Enclosure | 3U (5.25-inch), 19-inch wide,
29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase
and three phase models available. HP BladeSystem 3U p-Class power enclosure
provides external, shared hot-plug power. Each three-phase power enclosure
houses up to six hot-plug power supplies each single-phase power enclosures
hold up to four hot-plug power supplies to power the BL p-Class server blades
and interconnects. Please use the sizing utility to determine the power needed for each configuration. http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed. |
|
|
|
| HP BladeSystem p-Class 1U Power Enclosure | 1U (1.75-inch), 19-inch wide,
29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single phase
or three phase operation. HP BladeSystem p-Class 1U power enclosure provides external, hot-plug power. Each 1U power enclosure houses up to six hot-plug power supplies to power up to one server blade enclosure, fully populated with BL p-Class server blades and interconnects. Please use the sizing utility to determine the power needed for each configuration http://www.hp.com/go/bladesystem/powercalculator. Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed. |
|
|
|
| HP BladeSystem p-Class Power Distribution (only required with 3U power enclosures) |
In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power
(from the power enclosures or facility DC power) is distributed from the
power enclosures to the server blade enclosures through a bus bar system.
Hinges attach the HP BladeSystem bus bars to the rails in a rack. The
bus bars swing open from the center to enable easy rear access to the
server blades and network cables. Power is distributed redundantly through
independent A- and B-sided bus bars.
NOTE: To support a full 42U rack server blades (6 server blade enclosures), two mini bus bars are needed. |
|||
|
|
| Required Power Source | Two 30-amp redundant power feeds per power enclosure | ||
| Connectors | |||
| NEMA receptacles | |||
| 1-phase | L6-30, 250v, 30A 3-wire | ||
| 3-phase |
L15-30, 250V, 30A, 4-wire | ||
| Optimized for power cabling from bottom and network cabling from top | |||
|
|
Standard Features
|
ProLiant Essentials Foundation Pack Software for the ProLiant BL Server Blades |
|
||||
|
|||||
|
|||||
|
|||||
|
|||||
| NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials | |||||
|
|
|||||
| Optional ProLiant Essentials Value Packs |
Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs:
|
| NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. | |
|
|
|
| SmartStart |
SmartStart is a tool that simplifies single server setup, providing a
rapid way to deploy reliable and consistent server configurations. SmartStart
7.00 and later can now deploy the HP ProLiant BL20P G3 and HP ProLiant
BL40P server blades, using the I/O port with an attached USB CD-ROM device.
To obtain a copy of SmartStart for your blade server, redeem the coupon
that is included with your Blade server or order your copy from the SmartStart
web site. For more information, please visit the SmartStart Web site at
http://www.hp.com/servers/smartstart. |
|
|
|
| OS Support |
Microsoft® Windows 2000 Advanced Server NOTE: For a complete and up-to-date
listing of supported OSs and versions, please visit our OS Support Matrix
at: http://www.hp.com/go/supportos. |
|
|
|
| Intelligent Manageability |
Integrated Lights-Out Advanced (iLO)
Automatic Server Recovery-2 (ASR-2) |
|
|
|
| Availability |
Power redundancy: Redundant AC feeds into power enclosures; redundant
DC feeds from power enclosure to server blade enclosures, 1 + 1 redundant
power supplies
|
|
|
|
| Security |
Power-on password |
|
| |
| Minimum Rack Requirements |
Mounts in HP Telco racks and Third Party racks that meet the following criteria:
NOTE: If using 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are required. |
|
|
|
| Rack Airflow Requirements | Rack 10000 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/40p/documentation.html. | |
|
|
|
| Factory Express Portfolio for Servers and Storage | HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
|
|
| Service and Support | Three-year limited warranty,
including hardware diagnostic support, pre-failure warranty (coverage of
processors, memory and SCSI hard drives). The warranty is fully supported
by HP Services and a worldwide network of resellers and service providers.
In addition 90-day's getting started software telephone support may be covered
under the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services. NOTE: Sever Blade Limited Warranty includes 3 year Parts, 3 year Labour, 3-year on-site support. NOTE: Server Blade Enclosure and Interconnects Limited Warranty includes 3 year Parts, 3 year Labour, 3-year on-site support. NOTE: SATA drives have a 1 year warranty. Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including:
HP Care Pack services for ProLiant BL p-Class server blades, cover the
server blade and the p-Class blade enclosure that the server blade is
installed in as well as interconnects, power enclosure with power supplies
and power distribution. |
|
|
Models
| ProLiant
BL40p P3.0-4MB, 1GB (2P) 344286-B21 | Processor(s) | (2) Xeon MP 3.0 GHz standard (up to 4 supported) |
| Cache Memory | 4-MB Level 3 Cache (per processor) | |
| Memory | 1024 MB (Standard) of 2-way interleaved PC2100 ECC DDR (2 X 512 MB) | |
| Network Controller | Five NC7781 PCI-X Gigabit NICs
(embedded) with WOL and PXE One additional 10/100T NIC dedicated to iLO Management |
|
| Storage Controller | Smart Array 5i Plus Controller (integrated on system board) with BBWC | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 1200 GB maximum | |
| Optical Drive | None | |
| Form Factor | 6U high x 7" wide. Fits within p-Class Server Blade Enclosure | |
|
|
||
| ProLiant BL40p P2.2-2MB,
512MB (1P) 345628-B21 |
Processor(s) | (1) Xeon MP 2.2 GHz standard (up to 4 supported) |
| Cache Memory | 2-MB Level 3 Cache (per processor) | |
| Memory | 512 MB (Standard) of 2-way interleaved PC2100 ECC DDR (2 X 256 MB) | |
| Network Controller | Five NC7781 PCI-X Gigabit NICs
(embedded) with WOL and PXE One additional 10/100T NIC dedicated to iLO Management |
|
| Storage Controller | Smart Array 5i Plus Controller (integrated on system board) | |
| Hard Drives | None ship standard | |
| Internal Storage | Up to 1200 GB maximum | |
| Optical Drive | None | |
| Form Factor | 6U high x 7" wide. Fits within p-Class Server Blade Enclosure |
|
|
Options
| HP ProLiant BL40p server blade Unique Options | Xeon MP 3.0GHz 4MB Processor Option Kit | 344287-B21 |
| Xeon MP 2.2GHz 2MB Processor Option Kit | 345627-B21 | |
| HP BladeSystem p-Class Diagnostic Station Upgrade Kit for the HP ProLiant BL40p server blade |
309329-B21
|
|
|
|
||
| ProLiant
Essentials Value Pack Software |
ProLiant Essentials Intelligent Networking Pack | |
| ProLiant Essentials
Intelligent Networking Pack, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372906-B21
|
|
| NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_ca/11925_ca.html | ||
| ProLiant Essentials Performance Management Pack | ||
| ProLiant Essentials
Performance Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation. NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp. |
306696-B21
|
|
| NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_ca/11925_ca.html | ||
| ProLiant Essentials Rapid Deployment Pack Windows Edition and Linux Edition Release | ||
| Rapid Deployment
Pack, Single-Server License NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-B21
|
|
| NOTE:
For additional ProLiant Essentials Rapid Deployment Pack License Kits please
see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_ca/11053_ca.html
http://h18000.www1.hp.com/products/quickspecs/11713_ca/11713_ca.html |
||
| ProLiant Essentials Server Migration Pack | ||
| ProLiant Essentials
Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. |
375345-B21
|
|
| NOTE: For additional ProLiant Server Migration Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12170_ca/12170_ca.html | ||
| ProLiant Essentials Workload Management Pack | ||
| ProLiant Essentials Workload Management Pack, Single Server License |
303284-B21
|
|
| NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_ca/11452_ca.html | ||
| ProLiant Essentials Workload Management Pack | ||
| ProLiant Essentials Workload Management Pack, Single Server License |
303284-B21
|
|
| NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_ca/11452_ca.html | ||
| ProLiant Essentials Virtual Machine Management Pack | ||
| ProLiant Essentials
Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372214-B21
|
|
| NOTE: For additional ProLiant Virtual Machine Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12110_ca/12110_ca.html | ||
| ProLiant Essentials Vulnerability and Patch Management Pack | ||
| ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
371645-B21
|
|
| NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_ca/12111_ca.html | ||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the
various ProLiant Essentials Value Pack product QuickSpecs for more information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
||
|
|
||
| Processor | Xeon MP 3.0GHz 4MB Processor Option Kit | 344287-B21 |
| Xeon MP 2.2GHz 2MB Processor Option Kit | 345627-B21 | |
|
|
||
| Memory (DDR DIMMs) | 512MB of PC2100 ECC DDR DIMM Memory Kit (2x256MB) |
300678-B21 |
| 1024MB of PC2100 ECC DDR DIMM Memory Kit (2x512MB) |
300679-B21 | |
| 2048MB of PC2100 ECC DDR DIMM Memory Kit (2x1024MB) |
300680-B21 | |
| 4096MB of PC2100 ECC DDR DIMM Memory Kit (2x2048MB) |
300682-B21 | |
|
| ||
| Hard Drives | Wide Ultra320 Universal Hot Plug | |
| 300-GB 10,000 rpm U320 Universal Hard Drive (1") |
350964-B22
|
|
| 146.8-GB 10,000 rpm U320 Universal Hard Drive (1") |
286716-B22
|
|
| 72.8-GB 10,000 rpm U320 Universal Hard Drive (1") |
286714-B22
|
|
| 146.8-GB 15,000 rpm U320 Universal Hard Drive (1") |
347708-B22
|
|
| 72.8-GB 15,000 rpm U320 Universal Hard Drive (1") |
286778-B22
|
|
| 36.4-GB 15,000 rpm U320 Universal Hard Drive (1") |
286776-B22
|
|
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. | ||
| NOTE: Please
see the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature: U320 Hard Drive QS: http://h18000.www1.hp.com/products/quickspecs/11531_ca/11531_ca.html |
||
|
|
||
| Storage Controllers | Battery Backed Write Cache Enabler Option Kit |
255514-B21
|
| Smart Array 6402/128 Controller |
273915-B21
|
|
| Smart Array 6404/256 Controller |
273914-B21
|
|
| Smart Array 642 Controller |
291967-B21
|
|
| 256MB DDR, Battery-Backed Cache
Upgrade Kit for SA-6400 NOTE: This 256-MB Battery-Backed Cache Module upgrade kit supports the Smart Array 6400 series controller only. |
273913-B21
|
|
| 128MB Battery-Backed Cache Enabler NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller. |
||
| NOTE: Please see
the following Controller or SCSI Adapter QuickSpecs for Technical Specifications
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported,
SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache,
RAID support, and additional information: http://h18000.www1.hp.com/products/quickspecs/11063_na/11063_na.html (Smart Array 5i Plus) http://h18000.www1.hp.com/products/quickspecs/11587_na/11587_na.html (Smart Array 6400 Series) http://h18000.www1.hp.com/products/quickspecs/12069_na/12069_na.html (Smart Array 642) |
||
|
|
||
|
Tape Libraries |
HP StorageWorks MSL6000 Tape Library | |
| Ultrium 960 technology |
||
| MSL6030,
1 drive, 30 slots, Ultrium 960 |
AD606A
|
|
| MSL6030,
2 drive, 30 slots, Ultrium 960 |
AD607A
|
|
| MSL6030,
1 drive, 30 slots, Ultrium 960, with embedded FC router |
AD608A
|
|
| MSL6030,
2 drive, 30 slots, Ultrium 960, with embedded FC router |
AD609A
|
|
| MSL6060,
2 drive, 60 slots, Ultrium 960 |
AD610A
|
|
| MSL6060, 2 drive, 60 slots, Ultrium 960, with embedded FC router |
AD611A
|
|
| SDLT 600 technology |
||
| MSL6026, 1 drive, 26 slots, SDLT
600 |
AD582A
|
|
| MSL6026, 2 drive, 26 slots, SDLT
600 |
AD583A
|
|
| MSL6026,
1 drive, 26 slots, SDLT 600, with embedded FC router |
AD584A
|
|
| MSL6026, 2 drive, 26 slots, SDLT
600, with embedded FC router |
AD585A
|
|
| MSL6052, 2 drive, 52 slots, SDLT
600 |
AD587A
|
|
| MSL6052, 2 drive, 52 slots, SDLT 600, with embedded FC router |
AD588A
|
|
| Ultrium 460 technology |
||
| MSL6030, 1 drive, 30 slots, Ultrium
460 |
AD598A
|
|
| MSL6030, 2 drive, 30 slots, Ultrium
460 |
AD599A
|
|
| MSL6030, 1 drive, 30 slots, Ultrium
460, with embedded FC router |
AD600A
|
|
| MSL6030, 2 drive, 30 slots, Ultrium
460, with embedded FC router |
AD601A
|
|
| MSL6060, 2 drive, 60 slot Ultrium 460 |
AD603A
|
|
| MSL6060, 2 drive, 60 slot Ultrium 460, with embedded FC router |
AD604A
|
|
| NOTE: Please reference the MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
| HP StorageWorks MSL5026S2 Tape
Library |
||
| MSL5026S2,
1 DRV, SDLT320, RM Library |
293472-B22
|
|
| MSL5026S2, 2 DRV, SDLT320, RM
Library |
293472-B23
|
|
| MSL5026S2, 1 DRV, SDLT320, Fibre Channel, RM Library |
293472-B24
|
|
| MSL5026S2, 2 DRV, SDLT320, Fibre Channel, RM Library |
293472-B25
|
|
| NOTE: Please reference the MSL5026S2 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
| HP StorageWorks MSL5052S2 Tape
Library |
||
| MSL5052S2, 2 DRV, SDLT320, RM
Library |
293474-B21 | |
| MSL5052S2, 2 DRV, SDLT320, Fibre Channel, RM Library | 293474-B24 | |
| NOTE: Please reference the MSL5052S2 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
| HP StorageWorks MSL5060 Tape Library | ||
| MSL5060, 2 drive, 60 slots, Ultrium 230, RM with embedded FC router | 301899-B22 | |
| MSL5060, 2 drive, 60 slots, Ultrium 230, TT | 301899-B23 | |
| NOTE: Please reference the MSL5060 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
| HP StorageWorks ESL E-Series Tape Libraries | ||
| ESL Extended 712e Tape Library, 0 drive, 712 LTO slots | AA934B | |
| ESL Extended 630e Tape Library,
0 drive, 630 SDLT slots |
AA935B | |
| ESL Extended 322e Tape Library,
0 drive, 322 LTO slots |
AA939B | |
| ESL Extended 286e Tape Library,
0 drive, 286 SDLT slots |
AA940B | |
| ESL E-Series Ultrium 960 drive kit | AD595A | |
| ESL E Ultrium 460 drive kit |
AA937A | |
| ESL E Ultrium 460-FC drive kit | AA941A | |
| ESL E SDLT 320 drive kit | AA936A | |
| ESL E e2400-FC Interface Controller | AA928A | |
| NOTE: Please reference the ESL E-Series Tape Libraries QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
|
|
||
|
Magneto-Optical Jukeboxes |
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes | |
| 300mx, 2 drive, 32 slot jukebox | C1150M | |
| 600mx, 4 drive, 64 slot jukebox | C1160M | |
| 700mx, 2 drive, 76 slot jukebox | C1170M | |
| NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution | ||
| HP StorageWorks 9.1 GB High-end Optical Jukeboxes | ||
| 1200mx, 4 drive, up to 128 slots | C1104M | |
| 1200mx, 6 drive, up to 128 slots | C1105M | |
| 2200mx, 4 drive, up to 238 slots | C1111M | |
| 2200mx, 6 drive, up to 238 slots | C1107M | |
| 2200mx, 10 drive, up to 238 slots | C1110M | |
|
|
||
| HP BladeSystem p-Class Server Blade Enclosures | HP BladeSystem p-Class Server
Blade Enclosure with enhanced backplane components and the HP BladeSystem
Management Suite NOTE: Includes a HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components, a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM). NOTE: The HP ProLiant BL40p server blade does not currently support (PMP). Future support is planned. |
380625-B22
|
| HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components (ProLiant Essentials Rapid Deployment Pack Trial) |
243564-B22
|
|
| HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components (8 ProLiant Essentials Rapid Deployment Licenses) |
281404-B22
|
|
| HP BladeSystem p-Class Server
Blade Enclosure Upgrade Kit (option) NOTE: Server Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure. |
354100-B21
|
|
|
|
||
| HP BladeSystem p-Class Interconnects | ProLiant BL p-Class RJ-45 Patch
Panel 2 with Fibre Channel pass-through (pair) (required for ProLiant BL20p
G2 Fibre Channel connectivity when using the RJ-45 Patch Panel 2) NOTE: Only one interconnect kit required per server blade enclosure. |
306465-B21
|
| ProLiant BL p-Class RJ-45 Patch
Panel (pair) NOTE: Only one interconnect kit required per server blade enclosure. |
230766-B21
|
|
| ProLiant BL p-Class C-GbE2 Interconnect
Kit (with pair of GbE2 Interconnect Switches and two QuadT2 Interconnect
Modules) NOTE: Only one interconnect kit required per server blade enclosure. |
283192-B21
|
|
| ProLiant BL p-Class F-GbE2 Interconnect
Kit (with pair of GbE2 Interconnect Switches and two QuadSX Interconnect
Modules) NOTE: Only one interconnect kit required per server blade enclosure. |
283193-B21
|
|
| Cisco
Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit
Base Unit only NOTE: Two CGESM interconnect kits required per server blade enclosure. |
378926-B21
|
|
| Cisco Gigabit Ethernet Switch
Module for HP BladeSystem p-Class Interconnect Kit Base Unit (with two RJ-45
10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules. NOTE: Two CGESM interconnect kits required per server blade enclosure. |
378927-B21
|
|
| Cisco RJ-45 10/100/1000 T/TX/T SFP Module |
378928-B21
|
|
| Cisco Fiber SX SFP Module |
378929-B21
|
|
| ProLiant BL p-Class Storage Connectivity
Kit (with pair of OctalFC Interconnect Modules and two Fibre Channel signal
conditioning cards) NOTE: Required for BL20P G3 Fibre Channel signal pass through when using the CGESM or GbE2 Interconnect Switch. NOTE: Only one Storage Connectivity Kit required per each GbE2 Interconnect Kit. NOTE: Only one Storage Connectivity Kit required for (2) CGESM Interconnect Kit. |
321745-B21
|
|
| ProLiant BL p-Class C-GbE Interconnect
Kit (with pair of GbE Interconnect Switches and two QuadT Interconnect Modules) NOTE: Only one interconnect kit required per server blade enclosure. NOTE: The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is recommended that the GbE2 Interconnect Switch or a patch panel option be used if server NIC speeds to 1000 Mbps are required. NOTE: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit. |
249655-B21
|
|
| ProLiant BL p-Class F-GbE Interconnect
Kit (with pair of GbE Interconnect Switches and two DualTSX Interconnect
Modules) NOTE: Only one interconnect kit required per server blade enclosure. NOTE: The GbE Interconnect Switch supports server NIC speeds to 100 Mbps. It is recommended that the GbE2 Interconnect Switch or a patch panel option be used if server NIC speeds to 1000 Mbps are required. NOTE: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit. |
279720-B21
|
|
| ProLiant BL p-Class Storage Connectivity Kit (with two Fibre Channel signal conditioning cards and two OctalFC Interconnect Modules) (required for ProLiant BL20p G2 Fibre Channel connectivity when using the GbE2 Interconnect Switch) |
321745-B21
|
|
|
|
||
| HP BladeSystem p-Class Power options | NOTE: Use p-Class
sizing tool to help determine power configuration: http://www.hp.com/products/configurator. |
|
| Single Phase 3U Power Enclosure
with 4 power supplies (Single Phase 3U Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) |
239162-001
|
|
| 3 Phase 3U Power Enclosure with
6 power supplies (3 Phase 3U Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) |
230769-001
|
|
| Single Phase 3U Power Enclosure
(empty) (Holds up to 4 power supplies; power supplies are not included in this kit) |
231710-001
|
|
| 3 Phase 3U Power Enclosure (empty) (Holds up to 6 power supplies; power supplies are not included in this kit) |
231709-001
|
|
| Single 3U Power Supply |
239161-B21
|
|
| Facility DC Power Connection |
240563-B21
|
|
| 1U Power Enclosure with six power
supplies |
378284-B21
|
|
| 1U Power Enclosure with two power
supplies |
380314-B21
|
|
| Single 1U Power Supply |
380312-B21
|
|
|
|
||
| Power Distribution (only required with 3U power enclosures) | HP BladeSystem p-Class Scalable Bus Bar |
240560-B21
|
| HP BladeSystem p-Class Mini Bus Bar |
240559-B21
|
|
| HP BladeSystem p-Class Bus Power Box |
240562-B21
|
|
| HP Modular Distribution Unit 40
Amp* |
252663-D75
|
|
| HP Modular Distribution Unit 24 Amp* |
252663-D74
|
|
| *NOTE: The Modular
Distribution Unit Kits excludes the extension bars as they are not required
with the HP BladeSystem p-class 1U power enclosure. |
||
| HP BladeSystem Power Extension
Kit NOTE: When upgrading a standard server blade enclosure(s) to enhanced server blade enclosure(s) and using mini bus bars, this option kit allows a second, redundant 3U power enclosure to be installed above the server blade enclosure(s) rather than below. The option kit consists of two extension cable assemblies - one for each side (A and B) of the power infrastructure. |
381686-B21
|
|
|
|
||
| Diagnostic Options | HP BladeSystem p-Class Diagnostic
Station NOTE: The Diagnostic Station allows access to the ProLiant p-Class server blades and the BL p-Class interconnect switches outside of the server enclosure. The option provides power and a data interface so that "offline" upgrade and diagnostic functions may be performed. |
230743-B21
|
| HP BladeSystem p-Class Diagnostic Station Upgrade Kit for the HP ProLiant BL40p server blade |
309329-B21
|
|
|
|
||
| SAN Switches | McDATA 4Gb SAN Switch |
A8001A
|
| HP StorageWorks SANtegrity Enhanced License |
T4263A
|
|
| Brocade 4GB SAN Switch, Base |
A7533A
|
|
| Brocade 4GB SAN Switch, full fabric |
A7534A
|
|
| Brocade 4GB SAN Switch, power pack |
A7535A
|
|
|
|
||
| Other Options | HP BladeSystem p-Class Server
Enclosure Shipping Bracket Option Kit NOTE: Used to secure one server blade enclosure in a rack when moving. |
293121-B21
|
| HP BladeSystem p-Class Power Enclosure
Shipping Bracket Option Kit NOTE: Used to secure one power enclosure in a rack when moving. |
365044-B21
|
|
| External Storage - Rack | HP StorageWorks Modular Smart
Array 20 NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. |
335921-B21
|
| HP StorageWorks Modular Smart
Array 20 Starter Kit NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller. |
366172-B21
|
|
| NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 1" Hot Plug Hard Drives. | ||
| HP StorageWorks Modular Smart
Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies |
302969-B21
|
|
| HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies |
302970-B21
|
|
| NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 1" Hot Plug Hard Drives. | ||
| Redundant Power Supply 499W |
338296-B21
|
|
| Ultra320 Dual Bus I/O Module for MSA30 |
287483-B21
|
|
| Ultra320 Single Bus I/O Module for MSA30 |
287484-B21
|
|
| HP StorageWorks Modular Smart Array 500 | HP StorageWorks Modular Smart Array 500 Generation 2 |
335880-B21
|
| NOTE: Please see
the Modular Smart Array 500 Generation 2 QuickSpecs for additional information
including configuration steps and additional options needed for a complete
solution at: http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.html |
|
| HP StorageWorks Modular Smart Array 1500 cs | Modular Smart Array 1500 Controller Shelf |
AA986A
|
| NOTE: Please see
the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options
and configuration information at: http://www.hp.com/go/MSA1500cs |
|
|
HP StorageWorks Modular Smart Array 1000 |
HP StorageWorks Modular Smart Array 1000 |
201723-B22 |
|
Modular Smart Array 1000 Controller |
218231-B22 |
|
|
Modular Smart Array Fibre Channel I/O Module |
218960-B21 |
|
|
Modular Smart Array hub 2/3 |
286763-B21 |
|
| NOTE: Please see
the Modular Smart Array 1000 QuickSpecs for additional options and configuration
information at http://h18000.www1.hp.com/products/quickspecs/11033_ca/11033_ca.html |
||
|
|
||
|
Controllers and Host Bus Adapters |
FCA2404DC 2Gb PCI-X-to-FC HBA for W2K and Windows Server 2003 |
323264-B21
|
| FCA2404 2Gb PCI-X HBA for W2K and Windows Server 2003 |
305573-B21
|
|
| FCA2214 2Gb PCI-X FC HBA for Windows and Linux |
281541-B21
|
|
| FCA2214DC 2 Gb Dual Channel PCI-X FC HBA for Windows |
321835-B21
|
|
|
|
||
| Cluster Options | HP Serviceguard for Linux ProLiant Cluster, A.11.15 (2 license version - SUSE SLES8) |
305199-B24
|
| HP Serviceguard for Linux ProLiant Cluster, A.11.16 (2 license version - Red Hat EL 3&4, SUSE SLES9 |
305199-B26
|
|
| HP Serviceguard for Linux, A.11.15 (single license version - SUSE SLES8) |
307754-B24
|
|
| NOTE:
For additional information regarding the HP Serviceguard for Linux License,
please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_ca/11518_ca.html |
||
| ProLiant Cluster Kit with OpenView Storage Mirroring |
364025-B21
|
|
| ProLiant Cluster Starter Kit |
364023-B21
|
|
| NOTE: For additional
information regarding the ProLiant Cluster for HA/F100, HA/F200 for Modular
Smart Array 1000 please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11035_ca/11035_ca.html |
||
| ProLiant Cluster F500 for the Enterprise SAN |
364024-B21
|
|
| NOTE:
For additional information regarding the HP ProLiant Cluster for ProLiant
Cluster HA/F500 for Enterprise Virtual Array please see the following QuickSpecs
at: http://h18000.www1.hp.com/products/quickspecs/11055_ca/11055_ca.html |
||
| NOTE:
For additional information regarding the HP ProLiant Cluster for HA/F500
please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/10232_ca/10232_ca.html |
||
|
|
||
| StorageWorks Enterprise
Modular Array 16000 FC |
StorageWorks Director 2/64 |
286809-B21
|
| NOTE: Please see
the StorageWorks SAN Director 2/64 QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/11003_ca/11003_ca.html |
||
|
|
||
| USB Options | USB 1.44-MB External Diskette Drive (Carbonite) | DC141B |
| USB 2-Button Optical Mouse (Carbonite) | DC172B | |
| USB 2-Button Scroll Mouse (carbonite) |
DD441B
|
|
| 256MB Hp Drive Key II (USB 2.0) | PH657A | |
|
|
||
| HP Rack 5000 Series | HP5642 Rack-Unassembled |
358254-B21
|
|
|
||
| Rack Options for Rack 5000 Series |
Stabilizer Kit for 5642 Rack (Graphite
Carbon) NOTE; The stabilizer kit is used to prevent rack from tipping over. |
374493-B21
|
| Baying Kit for 5642 Rack (Graphite
Carbon) NOTE: The baying kit is used to join two or more HP 5642 rack. |
374499-B21
|
|
|
|
||
| HP Rack
10000 Series (Graphite Metallic)
|
Rack, HP Infrastructure 42U (HV) |
379005-001
|
| Rack, HP Infrastructure 42U (LV) |
379006-001
|
|
| HP S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22
|
|
| HP Rack 10842 (42U) - Pallet NOTE: Server Blade Enclosures must be field integrated into the 10842 racks. Factory integration of Server Blade Enclosures into the 10842 is not supported. |
257415-B21
|
|
| HP Rack 10842 (42U) - Shock Pallet NOTE: Server Blade Enclosures must be field integrated into the 10842 racks. Factory integration of Server Blade Enclosures into the 10842 is not supported. |
257415-B22
|
|
|
HP Rack 10842 (42U, 800mm wide) - Pallet |
245160-B21 |
|
|
HP Rack 10842 (42U, 800mm wide) - Shock Pallet |
245160-B23 |
|
|
HP Rack 10647 (47U) - Pallet |
245161-B21 |
|
|
HP Rack 10647 (47U) - Crated |
245161-B22 |
|
|
HP Rack 10642 (42U) - Pallet |
245161-B23 |
|
|
HP Rack 10642 (42U) - Shock Pallet |
245162-B21 |
|
|
HP Rack 10642 (42U) - Crated |
245162-B22 |
|
|
HP Rack 10636 (36U) - Pallet |
245162-B23 |
|
|
HP Rack 10636 (36U) - Shock Pallet |
245163-B21 |
|
|
HP Rack 10636 (36U) - Crated |
245163-B22 |
|
|
HP Rack 10622 (22U) - Pallet |
245163-B23 |
|
| NOTE: -B21 (pallet)
used to ship empty racks shipped on a truck -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipments of empty racks NOTE: Not all HP equipment is qualified to be shipped in the Rack 10000 series. |
||
|
|
||
|
Rack Options for HP |
HP Rack Light Kit (Neon) |
361589-B21
|
| HP Rack Plinth Kit (Carbon) |
251960-B21
|
|
|
800mm Wide Stabilizer Kit (Graphite) |
255488-B21 |
|
| NOTE: Supported by the Rack 10842 cabinet only. | ||
|
600mm Stabilizer Kit – Graphite |
246107-B21 |
|
|
Baying Kit for Rack 10000 series (Carbon) |
248929-B21 |
|
|
42U Side Panel – Graphite Metallic |
246099-B21 |
|
|
110V Fan Kit (Graphite) |
257413-B21 |
|
| NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 5-15P. | ||
|
220V Fan Kit (Graphite) |
257414-B21 |
|
| NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 6-15P. | ||
|
36U Side Panel – Graphite Metallic |
246102-B21 |
|
|
47U Side Panel – Graphite Metallic |
255486-B21 |
|
|
9000/10000 Series Offset Baying Kit (42U) |
248931-B21 |
|
| NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U height together. Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks. | ||
| NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. | ||
| Ballast Option Kit |
120672-B21
|
|
| 9000/10000 Series Offset Baying Kit (42U) |
248931-B21
|
|
| NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U height together. Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks. | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html | ||
|
100 kg Sliding Shelf |
234672-B21 |
|
|
Monitor/Utility Shelf - Graphite |
253449-B21 |
|
|
Depth Adjustable Fixed Rail |
332558-B21 |
|
|
Cable Management D-Rings Kit |
168233-B21 |
|
|
TFT5600 Rack Keyboard Monitor |
221546-xx1 |
|
| TFT7210R Rack Mounted 17" Monitor |
348373-B21
|
|
| TFT5600 Rack Keyboard Monitor |
221546-xx1
|
|
| 1U Rack Keyboard & Drawer (Carbon) |
257054-xx1
|
|
| NOTE: For a complete
list of Monitors please view the following URL: http://h18004.www1.hp.com/products/monitors/ |
||
| NOTE: For additional information regarding Rack Options, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. | ||
|
|
||
| HP KVM Switch Options | IP Console Switch Box (KVM/IP), 1 x 1 x 16 |
262585-B21
|
| IP Console Switch Box (KVM/IP), 3 x 1 x 16 |
262586-B21
|
|
| Serial Interface adapter - 1 Pack
with power supply |
373035-B21
|
|
| Interface adapter - USB 1.0 (single pack) |
336047-B21
|
|
| CAT5e Cable 3', 4 pack |
263474-B21
|
|
| CAT5e Cable 6', 8 pack |
263474-B22
|
|
| CAT5e Cable 12', 8 pack |
263474-B23
|
|
| CAT5e Cable 20', 4 pack |
263474-B24
|
|
| CAT5e Cable 40', 1 pack |
263474-B25
|
|
|
|
||
| Rack Options for Telco Racks | Bus Bar Telco Rail Option Kit |
245249-B21
|
| Enclosure Telco Rail Option Kit |
266076-B21
|
|
|
|
||
| Service and Support Offerings (HP Care Pack Services) |
| ||||||||||||||||||||||||||||||||
|
|
|
Memory
|
HP ProLiant BL40p Server Blade (2P Model) |
|
Standard Memory 1024-MB of 2-way interleaved PC2100 ECC DDR installed (2 x 512-MB SDRAM DIMM) Standard Memory Plus Optional Memory Up to 9216-MB of 2-way interleaved PC2100 ECC DDR memory is available with the installation of optional DDR DIMM memory expansion kits. Standard Memory Replaced with Optional Memory Up to 12288-MB of 2-way interleaved PC2100 ECC DDR memory is available with the removal of standard memory and the installation of optional DDR DIMM memory expansion kits. |
|
Memory |
Slot |
||||||
|
1 |
2 |
3 |
4 |
5 |
6 |
||
|
Standard
|
1,024MB
|
512 MB |
512 MB |
Empty |
Empty |
Empty |
Empty |
|
Optional
|
9,216MB
|
512 MB |
512 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
Maximum
|
12,288 MB
|
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
Following are memory options available from HP: |
|
|
300678-B21 |
|
300679-B21 |
|
300680-B21 |
|
300682-B21 |
|
|
|
|
HP ProLiant BL40p Server Blade (1P Model) |
|
Standard Memory 512MB of 2-way interleaved PC2100 ECC DDR installed (2 x 256-MB SDRAM DIMM) Standard Memory Plus Optional Memory Up to 8704-MB of 2-way interleaved PC2100 ECC DDR memory is available with the installation of optional DDR DIMM memory expansion kits. Standard Memory Replaced with Optional Memory Up to 12288-MB of 2-way interleaved PC2100 ECC DDR memory is available with the removal of standard memory and the installation of optional DDR DIMM memory expansion kits. |
|
Memory |
Slot |
||||||
|
1 |
2 |
3 |
4 |
5 |
6 |
||
|
Standard
|
512MB
|
256 MB |
256 MB |
Empty
|
Empty
|
Empty
|
Empty
|
|
Optional
|
4,608MB
|
256 MB |
256 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
Maximum
|
12,288MB
|
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
2048 MB |
|
Following are memory options available from HP: |
|
|
300678-B21 |
|
300679-B21 |
|
300680-B21 |
|
300682-B21 |
|
|
Technical Specifications
|
HP BladeSystem p-Class Server Blade Enclosure |
Dimensions | Height | 10.5 in (26.67 cm) |
| Width | 17.60 in (44.70 cm) | ||
| Depth | 28.86 in (73.30 cm) | ||
| Input Specifications | Rated input voltage | -43 VDC to -53 VDC Nominal -48 VDC | |
| Rated input current | 62.5 A at -48 VDC | ||
| Rated input Power | 3000 W | ||
| Individual server blade bay ratings | Rated input voltage | -43 VDC to -53 VDC Nominal -48 VDC | |
| Rated input current | 6.25 A at -48 VDC | ||
| Rated input Power | 300 W | ||
| Temperature range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-Operating | -22° to 140° F (-30° to 60° C) | ||
| Relative humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-Operating | 5% to 95% | ||
| Wet bulb temperature | Operating | 82.4° F (28° C) | |
| Non-Operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
|
HP BladeSystem p-Class Server Blade Enclosure with enhanced backplane components |
Dimensions | Height | 10.5 in (26.67 cm) |
| Width | 17.60 in (44.70 cm) | ||
| Depth | 28.86 in (73.30 cm) | ||
| Input Specifications | Rated input voltage | -43 VDC to -53 VDC Nominal -48 VDC | |
| Rated input current | 125 A at -48 VDC | ||
| Rated input Power | 6000 W | ||
| Individual server blade bay ratings | Rated input voltage | -43 VDC to -53 VDC Nominal -48 VDC | |
| Rated input current | 14.6 A at -48 VDC | ||
| Rated input Power | 700 W | ||
| Temperature range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-Operating | -22° to 140° F (-30° to 60° C) | ||
| Relative humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-Operating | 5% to 95% | ||
| Wet bulb temperature | Operating | 82.4° F (28° C) | |
| Non-Operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
|
Operating and Performance Specifications for HP ProLiant BL40p Server Blade | Dimensions | Height | 1.69 in (4.29 cm) |
| Width | 10.29 in (26.14 cm) | ||
| Depth | 28.00 in (71.12 cm) | ||
| Weight (maximum) | 18.0 lb (8.17 kg) | ||
| Temperature range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | |||
| Shipping | -40° to 140° F (-40° to 60° C) | ||
| Storage | -4° to 140° F (-20° to 60° C) | ||
| Relative
humidity (non-condensing) | Operating | 10% to 90% | |
| Non-operating | |||
| Shipping | 10% to 90% | ||
| Storage | 10% to 95% | ||
| Maximum wet bulb temperature | 82° F (28° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
| | |||
| Operating and Performance Specifications for RJ-45 Patch Panel 2 with Fibre Channel pass through | Dimensions | Height | 10.405 in (26.43 cm) |
| Width | 1.535 in (3.899 cm) | ||
| Depth | 27.697 in (70.35 cm) | ||
| Capability | IEEE 802.2, 802.3, 802.3u | ||
| Network Transfer Rate | 10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (full-duplex) | 1000 Mbps | ||
| Connector | Network | RJ-45 in the back | |
| Fibre Channel SAN | Pluggable SFP optical slot in the front | ||
| Cable Support | 10 Base-TX | Categories 3, 4, or 5 UTP (2 or 4 pair); up to 328 ft (100 m) | |
| 100 Base-TX | Category 5 UTP (2 pair); up to 328 ft (100 m) | ||
| 1000 Base-TX | Category 5E (4 pair); up to 328 ft (100 m) | ||
| Power requirements | 200 mA at + 5V DC; 500 mA at -48V | ||
| Temperature range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative humidity
(non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet bulb temperature | Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating and Performance Specifications for RJ-45 Patch Panel | Dimensions | Height | 10.405 in (26.43 cm) |
| Width | 1.535 in (3.899 cm) | ||
| Depth | 27.697 in (70.35 cm) | ||
| Capability | IEEE 802.2, 802.3, 802.3u | ||
| Network Transfer Rate | 10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (full-duplex) | 1000 Mbps | ||
| Connector | RJ-45 | ||
| Cable Support | 10 Base-TX | Categories 3, 4, or 5 UTP (2 or 4 pair); up to 328 ft (100 m) | |
| 100 Base-TX | Category 5 UTP (2 pair); up to 328 ft (100 m) | ||
| 1000 Base-TX | Category 5E (4 pair); up to 328 ft (100 m) | ||
| Power requirements | 200 mA at + 5V DC; 500 mA at -48V | ||
| Temperature range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative
humidity (non-condensing) | Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet bulb temperature | Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
| | |||
| Operating and Performance Specifications for ProLiant BL p-Class GbE Interconnect Switch |
Dimensions | Height | 10.405 in (26.43 cm) |
| Width | 1.535 in (3.899 cm) | ||
| Depth | 27.697 in (70.35 cm) | ||
| Weight | 11.5 lb/5.2 kg per interconnect switch | ||
| Performance | 9.6 Gbps external port bandwidth per server blade enclosure (full duplex) | ||
| Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per gigabit port, (64-byte packets) | |||
| Non-blocking, full-wire speed for all connections | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
| Forwarding Mode | Store and forward | ||
| MAC Addresses | 8,191 per interconnect switch; MAC address based filtering and MAC address packet priority configuring | ||
| Forwarding table age time | Maximum age: 1 to 1,000,000 seconds; default: 300 seconds | ||
| Memory | 32MB Main, 6MB flash and 16MB packet buffer per interconnect switch | ||
| Compliance | IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE only), 802.1D, 802.1p, 802.3ac, 802.3ad (Static), and 802.1Q | ||
| SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 | |||
| MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC 2674), Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch MIBs and Environmental Traps | |||
| IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC 854), TFTP client (RFC 783), BootP client, (RFC 2132), DHCP client, (RFC 2131) and Modem, | |||
| Network Transfer Rate | 10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 12 RJ-45, 2 DB-9
(C-GbE Interconnect Kit) 4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit) |
||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| Safety | UL/CUL Listed Accessory | ||
| CE | |||
| Power Requirements | -48VDC: 1050 mA, 50 W maximum (per interconnect switch) | ||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (30° to 60° C) | ||
| Relative humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature | Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating and Performance Specifications for GbE2 Interconnect Switch | Dimensions | Height | 10.405 in (26.43 cm) |
| Width | 1.535 in (3.899 cm) | ||
| Depth | 27.697 in (70.35 cm) | ||
| Weight | 12.0 lb/5.4 kg per interconnect switch | ||
| Performance | 24 Gbps External port bandwidth per server blade enclosure (full duplex) | ||
| Forwarding rate 1.5 million pps per gigabit port (64-byte packets) | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
| Forwarding Mode | Store and forward | ||
| MAC Addresses | 2,048 per interconnect switch | ||
| Forwarding table age time | Maximum age: 1 to 65535 seconds; default: 300 seconds | ||
| Memory | 128MB Main, 32MB flash and 2MB packet buffer per interconnect switch | ||
| Compliance | IEEE 802.3, 802.3u, 802.3ab, 802.3x, 802.3z (F-GbE2 only), 802.1D, 802.1s, 802.3ac, 802.3ad (Static), and 802.1Q | ||
| SNMP v1 (RFC 1157), MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB , Entity MIB (RFC 2037), RADIUS Authentication MIB, 802.3-2002 MIB, SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757) and HP Enterprise Switch MIBs and Environmental Traps | |||
| RADIUS (RFC 2138), Telnet (RFC 854), TFTP client (RFC 783), SSH v1.5, SCP v1.5, NTP v2 (RFC 1119), BOOTP client (RFC 2132), and XModem | |||
| Network Transfer Rate | 10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 12 RJ-45, 2 DB-9
(C-GbE2 Interconnect Kit) 8 LC fiber, 4 RJ-45, 2DB-9 (F-GbE2 Interconnect Kit) |
||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| Safety | UL/CUL Listed Accessory | ||
| CE | |||
| Power Requirements | -48VDC: 2040 mA, 98 W maximum (per interconnect switch without Storage Connectivity Kit) | ||
| -48VDC: 2355 mA, 113 W maximum (per interconnect switch with Storage Connectivity Kit) | |||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (30° to 60° C) | ||
| Relative humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet Bulb Temperature | Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/9,144 m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F/45° C. Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating and Performance Specifications for GbE Interconnect Switch | Dimensions | Height | 10.41 in (26.43 cm) |
| Width | 1.54 in (3.9 cm) | ||
| Depth | 27.7 in (70.35 cm) | ||
| Weight | 11.5 lb/5.2 kg per interconnect switch | ||
| Performance | 9.6 Gbps external port bandwidth per server blade enclosure (full duplex) | ||
| Forwarding rate 0.15 million pps per 10/100 port, 1.5 million pps per gigabit port, (64-byte packets) | |||
| Non-blocking, full-wire speed for all connections | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
| Forwarding Mode | Store and forward | ||
| MAC Addresses | 8,191 per interconnect switch; MAC address based filtering and MAC address packet priority configuring | ||
| Forwarding table age time | Maximum age: 1 to 1,000,000 seconds; default: 300 seconds | ||
| Memory | 32MB Main, 6MB flash and 16MB packet buffer per interconnect switch | ||
| Compliance | IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.1D, 802.1p, 802.3ac, 802.3ad (Static), 802.1Q, and 802.3x | ||
| SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9 | |||
| MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface Group MIB (RFC 2863), Ethernet MIB (RFC 1643), 802.1Q Extended Bridge MIB (RFC 2674), Entity MIB (RFC 2037), SNMP Trap Convention (RFC 1215), Bridge Trap (RFC 1493), Remote Monitoring Traps (RFC 1757), and HP Enterprise Switch MIBs and Environmental Traps | |||
| IGMP v1 (RFC 1112), IGMP v2 (RFC 2236), SNTP (RFC 1361), Telnet (RFC 854), TFTP client (RFC 783), BOOTO client, (RFC 2132), DHCP client, (RFC 2131) and ZModem | |||
| Network transfer rate | 10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 12 RJ-45, 2 DB-9 (C-GbE
Interconnect Kit) 4 LC fiber, 8 RJ-45, 2 DB-9 (F-GbE Interconnect Kit) |
||
| EMI | FCC Class A | ||
| ICES-003 Class A | |||
| AS/NZS 3548 Class A | |||
| VCCI Class A | |||
| Safety | UL/CUL Listed Accessory | ||
| CE | |||
| Power Requirements | 48V: 1050 mA, 50 W maximum (per interconnect switch) | ||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet bulb temperature | Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
| Operating and Performance Specifications for CGESM Interconnect Switch |
Dimensions | Height | 10.405 in (26.43 cm) |
| Width | 1.6 in (4.06 cm) | ||
| Depth | 28 in (71.12 cm) | ||
| Weight | 11.5 lb/5.2 kg per interconnect switch | ||
| Performance | 28 Gbps Maximum Forwarding Bandwidth. 38.7mpps Maximum Forwarding Rate (64 Byte Packets) | ||
| 9018Bytes Jumbo Frames MTU | |||
| Non-blocking architecture. Wire Speed Performance on all ports | |||
| Auto-MDI/MDIX, auto-negotiation and auto-sensing with full-duplex support | |||
| Forwarding Mode | Store and forward | ||
| MAC Addresses | 8000 MAC/physical address Table Size | ||
| Memory | 128MB DRAM Memory. 16MB Flash Memory | ||
| Compliance | IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3ad, IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and, IEEE 802.1D Spanning-Tree Protocol, IEEE 802.1p CoS Prioritization, IEEE 802.1Q VLAN, IEEE 802.3 10BASE-T specification, IEEE 802.3u 100BASE-TX specification, IEEE 802.3ab 1000BASE-T specification, IEEE 802.3z 1000BASE-X specification | ||
| RMON I and II standards, SNMPv1, SNMPv2c, and SNMPv3 | |||
| (RFC1493) , CISCO-CDP-MIB, CISCO-CLUSTER-MIB, CISCO-CONFIG-MAN-MIB, CISCO-ENTITY-FRU-CONTROL-MIB, CISCO-ENVMON-MIB, CISCO-FLASH-MIB, CISCO-FTP-CLIENT-MIB, CISCO-IGMP-FILTER-MIB, CISCO-IMAGE-MIB, CISCO IP-STAT-MIB, CISCO-MAC-NOTIFICATION-MIB, CISCO-MEMORY-POOL-MIB, CISCO-PAGP-MIB, CISCO-PING-MIB, CISCO-PROCESS-MIB, CISCO-RTTMON-MIB, CISCO-STP-EXTENSIONS-MIB, CISCO-SYSLOG-MIB, CISCO-TCP-MIB, CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB, CISCO-VLAN-MEMBERSHIP-MIB, CISCO-VTP-MIB, ENTITY-MIB, ETHERLIKE-MIB, IF-MIB (in and out counters for VLANs are not supported), IGMP-MIB, OLD-CISCO-CHASSIS-MIB, OLD-CISCO-FLASH-MIB, OLD-CISCO-INTERFACES-MIB, OLD-CISCO-IP-MIB, OLD-CISCO-SYS-MIB, OLD-CISCO-TCP-MIB, OLD-CISCO-TS-MIB, RFC1213-MIB (per the agent capabilities specified in the, CISCO-RFC1213-CAPABILITY.my), RFC1253-MIB, RMON-MIB, RMON2-MIB, SNMP-FRAMEWORK-MIB, SNMP-MPD-MIB, SNMP-NOTIFICATION-MIB, SNMP-TARGET-MIB, SNMPv2-MIB, TCP-MIB, UDP-MIB | |||
| 1000BASE-T ports, 1000BASE-X (SFP), 1000BASE-SX | |||
| Network transfer rate | 10 Base-T (half-duplex) | 10 Mbps | |
| 10 Base-T (full-duplex) | 20 Mbps | ||
| 100 Base-TX (half-duplex) | 100 Mbps | ||
| 100 Base-TX (full-duplex) | 200 Mbps | ||
| 1000 Base-TX (half and full-duplex) | 2000 Mbps | ||
| 1000 Base-SX (full-duplex) | 2000 Mbps | ||
| Connector | 4 SFP, 2 RJ-45 10/100/1000 T/TX/T, 1 DB-9 | ||
| EMI | FCC Part 15 Class A | ||
| EN 55022: 1998 (CISPR22)
EN 55024: 1998 (CISPR24) CNS 13438 Class A MIC CD MIC |
|||
| AS/NZS 3548 Class A CE | |||
| VCCI Class A | |||
| Safety | UL to UL 60950, Third
Edition C-UL to CAN/CSA C22.2 No. 60950-00, Third Edition TUV/GS to EN 60950:2000 CB to IEC 60950 with all country deviations NOM to NOM-019-SCFI |
||
| CE Marking | |||
| Power Requirements | -48VDC: 1050 mA, 125 W maximum (per interconnect switch) | ||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Non-operating | -22° to 140° F (-30° to 60° C) | ||
| Relative humidity (non-condensing) |
Operating | 20% to 80% | |
| Non-operating | 5% to 95% | ||
| Wet bulb temperature | Operating | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | |||
|
|
|||
|
Operating and Performance Specifications for Power Enclosures |
Single-Phase Model |
Three-Phase Model | ||
| Dimensions | Height | 5.25 in (13.34 cm) | 5.25 in (13.34 cm) | |
| Width | 27.15 in (68.96 cm) | 27.15 in (68.96 cm) | ||
| Depth | 17.60 in (44.7 cm) | 17.60 in (44.7 cm) | ||
| Weights | No hot-plug power supplies | 47.5 lb (21.55 kg) | 47.5 lb (21.55 kg) | |
| All hot-plug power supplies | 99.5 lb (45.13 kg) | 125.5 lb (56.93 kg) | ||
| Input requirements | Rated input voltage | 200 VAC to 240 VAC | 200 VAC to 240 VAC line to line | |
| Rated input frequency | 50 Hz to 60 Hz | 50 Hz to 60 Hz | ||
| Rated input current per side | 24A | 24A per phase | ||
| Rated input power per side | 5760 W | 9976 W | ||
| Power cord | 1 NEMA L6-30P per side | 1 NEMA L15-30 per side | ||
| Output voltage specifications | Rated output voltage | -48.8 VDC to 54 VDC | -48.8 VDC to 54 VDC | |
| Rated output current | 99A | 170A | ||
| Rated output power | 4298 W | 8310 W | ||
| Nominal power | 4158 W at 208 VAC | 7202 W at 208 VAC | ||
| Ambient
temperature range (See NOTE) | Operating | 50°
to 95° F (10° to 35° C) | 50°
to 95° F (10° to 35° C) | |
| Shipping | -22°
to 140° F (-30° to 60° C) | -22°
to 140° F (-30° to 60° C) | ||
| Relative
humidity, non-condensing (See NOTE) | Operating | 20% to 80% | 20% to 80% | |
| Non-operating | 5% to 95% | 5% to 95% | ||
| Wet bulb temperature | Operating | 82.4° F (28° C) | 82.4° F (28° C) | |
| Non-operating | 101.7° F (38.7° C) | 101.7° F (38.7° C) | ||
| NOTE: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Upper operating limit is 10,000 ft (3,048 m) or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft (9,144 m) or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of 113° F (45° C). Altitude maximum for storage is 70 KPa. | ||||
| | ||||
| Operating and Performance Specifications for Power Distribution Devices | Power Bus Box |
Mini Bus Bar
|
Scalable Bus Bar
|
|
| Power enclosures or facility DC feeds supported (3U each) |
1
|
1
|
2
|
|
| Server blade enclosures supported (6U each) |
1
|
3
|
5
|
|
| Total rack height of supported enclosures |
9U
|
21U
|
36U
|
|
| Dimensions | ||||
| Height | 5.1 in (12.95 cm) | 19.45 in (49.40 cm) | 48.57 in (123.37 cm) | |
| Width | 3.6 in (9.14 cm) each | 19.74 in (50.14 cm) | 19.74 in (50.14 cm) | |
| Depth | 3.25 in (8.26 cm) | 2.2 in (5.59 cm) | 2.2 in (5.59 cm) | |
| Weight | 3.62 lb (1.64 kg) | 13.2 lb (5.9 kg) | 26 lb (11.79 kg) | |
| Rated operating voltage | -43.2 VDC to -54 VDC | -43.2 VDC to -54 VDC | -43.2 VDC to -54 VDC | |
| Max total power supported |
3000 W
|
9000 W
|
15,000 W
|
|
| Total max input current at minimum voltage | 69.44 A at -43.2VDC | 208.32 A at -43.2 VDC | 347.2 A at -43.2 VDC (equivalent of 175A per feed) |
|
| Total max input current at nominal voltage | 62.5 A at -48VDC | 187.5 A at -48 VDC | 312.5 A at -48 VDC (equivalent of 175A per feed) |
|
| Max current per power feed |
70A
|
210A
|
210A
|
|
| Max local ambient temperature |
149° F (65° C)
|
149° F (65° C)
|
149° F (65° C)
|
|
| NOTE: All systems support redundant A & B feeds. Scalable bus bar supports dual A and dual B feeds. | ||||
|
|
||||
| Operating and Performance Specifications for Facility DC | Voltage | Nominal input voltage | -48 VDC |
| Operating voltage range | -48VDC ± 10% or -43.2 VDC to -52.8 VDC | ||
| Max Input voltage slew rate | 0.5V/uS | ||
| Redundant
feed voltages* (A & B) | *A and B feeds must differ by no more than 5VDC during steady state operation | ||
| Ripple/Noise | 480 mV PARD** | ||
| Overshoot | Must remain within regulation limits on all feeds during startup or shutdown | ||
| Voltage transients | Must not exceed -60 VDC | ||
| Current | Max steady state input current | 62.5A per server blade enclosure installed at -48VDC | |
| Max steady state current per feed/total | |||
| 70 A/70A | ||
| 210 A/210A | ||
| 210 A/350A or equivalent of 175A per feed* | ||
| In-rush current | Must support up to 2X the maximum operating current per server blade enclosure (125 A) for up to 1.0 mS | ||
| Input over-current | Customer provided fusing for facility DC feeds that protects the system from catastrophic over-current within 20 uS. Fuse should sustain all in-rush and operating currents. | ||
| Max Input Current Slew Rate | 1A/uS | ||
| Max Rated Power | 3000W per server blade enclosure | ||
| Connections and Cables | HP provided facility DC cable connection kit:
The power cable assemblies consist of 1/0AWG, colour-coded, flexible cable rated at 105° C, terminated with bus mating connectors at one end and unterminated at the other end. The cable length provided enables the customer to route to a fuse panel within or adjacent to the rack. | ||
| NOTE:
*All systems support redundant A and B feeds. Scalable bus bars support dual A
and dual B feeds. ** Periodic and random noise (PARD). Maximum allowable peak-to-peak ripple and noise (as measured at the load on any output channel). The ripple and noise is measured over a 20 Hz to 100 MHz frequency band. A resistive load (non-electronic) is used for this measurement. Each output is by-passed to return by a 10uF tantalum capacitor with an ESR less than 100 milli-Ohms in parallel with a 0.47 uF ceramic capacitor, at the point of load. The load cable is 12 feet of twisted wire capable of carrying the current. The printed wiring board assembly is installed in its enclosure for this measurement, or the measurement leads are properly shielded with Earth grounds applied to the insert. | |||
|
| |||
|
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |