| The Smart Array Advantage |
HP's innovative design and integration
work of the Smart Array family of products creates customer value that is
unmatched in the industry. Use of Smart Array products across multiple applications
results in a much lower Total Cost of Ownership (TCO) than any other server
storage RAID products. The HP Smart Array family brings an unparalleled
return on investment through: |
| |
Data Compatibility |
Data Compatibility among all models of Smart
Array controllers allows simple and easy upgrades any time needs for higher
performance, capacity, and availability increase. Even successive generations
of Smart Array controllers understand the data format of other Smart Array
Controllers. |
| |
Consistent Configuration and Management
Tools |
All Smart Array products utilize a standard
set of management and utility software. These tools minimize Total Cost
of Ownership (TCO) by reducing training requirements and technical expertise
necessary to install and maintain the HP server storage. |
| |
Universal Hard Drive |
Form factor is for use across multiple HP
ProLiant servers, disk enclosures and storage systems. With compatibility
across many enterprise platforms, you are free to deploy and re-deploy these
drives to quickly deliver increased storage capacity, migrate data between
systems, and easily manage spare drives. |
| |
Pre-Failure Warranty |
Pre-Failure Warranty means Insight Manager
not only reports when a drive is going to fail but allows replacement of
failing drives prior to actual failure. For complete details, consult the
HP Support Center or refer to your HP Server documentation. |
|
| Key Features for both Smart
Array 641 and Smart Array 642 Controllers |
- Compatibility with all Ultra 320, Ultra3 and Ultra2 LVD family products.
In addition, a seamless upgrade to next generation HP high performance
and high capacity mainstream Ultra320 Smart Array controllers.
- Recovery ROM protects against a ROM corruption.
- Ultra320 SCSI technology delivers high performance and data bandwidth
up to 320-MB/s bandwidth per channel.
- Modular, easy-to-upgrade design lets you optimize performance as needed
with the 64MB BBWC Enabler, from 64-MB of memory for RAID and read cache
to 128-MB of memory for RAID, read cache, and BBWC.
- Mix-and-match LVD SCSI compatibility protects your investments and
lets you deploy drives as needed.
- Software consistency among all Smart Array family products: Array
Configuration Utility XE (ACU-XE), Array Configuration Utility (ACU),
Insight Manager (CIM), Array Diagnostic Utility (ADU) and SmartStart.
- 64-bit, 133-MHz PCI-X interface boosts bandwidth above 1B/s burst
transfer rate over PCI-X bus.
- 64-bit memory addressing supports servers with greater than 4 GB of
memory.
- 64-MB memory optimizes performance and data throughput.
NOTE:
64 MB of DDR memory used
for RAID and read cache.
|
| |
Online Management Features |
Online Capacity Expansion, Online RAID Level
Migration, Online Stripe Size Migration, Online Spares (Global), User Selectable
Expand and Rebuild Priority |
| |
Channels |
- SA 641 : Single Channel provide the ability to support up to
6 drives or 880.8GB
- SA 642 : Dual Channels provide the ability to support up to
20 (6 internal, 14 external) drives or 2.9TB
|
|
| Key Features for 64MB BBWC
Enabler |
- Battery-backed Cache protects cached data in the event of a power
outage, server failure or controller failure.
- 72 hours of battery charge protects the data for an entire weekend.
- 3 years of battery life.
- Modular, easy-to-upgrade design lets you optimize performance as needed
with the 64MB BBWC Enabler, from 64-MB of memory for RAID and read cache
to 128-MB of memory for RAID, read cache, and BBWC.
|
|
| HP Care Pack Information |
Sample part numbers: |
| 3 year, uplift to 5 x 9, Next
Day Response |
FM-**XHW-36
|
| 3 year, uplift to 5 x 9, 4-hour
Response |
FM-**4HR-36
|
| 3 year, uplift to 7 x 24, 4-hour
Response |
FM-**724-36
|
| ** Represents
a two-digit, product-specific code |
| |
HP Care Pack is defined
as an upgrade to the product warranty attribute, available for a specific
duration and hours of coverage. |
| |
HP Care Pack is not
available for less than the product's warranty duration. |
| |
HP Care Pack is available
for sale anytime during the warranty period for most products, but the commencement
date will be the same as the Warranty Start Date (delivery date to end user
customer). Proof of purchase may be required. |
| |
HP Care Pack services
are prepaid. |
| |
For additional HP
Care Pack (hardware & software) information, as well as orderable part
numbers, please refer to the URL http://www.hp.com/hps/carepack/ |
| Hard Drives |
Wide Ultra3 SCSI Universal
Drives Hot Plug |
|
| 36.4-GB Wide Ultra3 SCSI 15,000
rpm Drive (1") |
232916-B22 |
| 18.2-GB Wide Ultra3 SCSI 15,000
rpm Drive (1") |
188122-B22 |
| 9.1-GB Wide Ultra3 SCSI 15,000
rpm Drive (1") |
188120-B22 |
| 72.8-GB Wide Ultra3 SCSI 10,000
rpm Drive (1") |
232432-B22 |
| 36.4-GB Wide Ultra3 SCSI 10,000
rpm Drive (1") |
176496-B22 |
| |
18.2-GB Wide Ultra3 SCSI 10,000
rpm Drive (1") |
142673-B22 |
| |
9.1-GB Wide Ultra3 SCSI 10,000
rpm Drive (1") |
142671-B22 |
| |
36-GB Wide Ultra3 SCSI 10,000
rpm Drives (1"), 10 pack |
232617-B21 |
| |
18-GB Wide Ultra3 SCSI 10,000
rpm Drives (1"), 10 pack |
202352-B21 |
| |
Wide Ultra320 SCSI Drives
Hot Plug |
|
| |
146.8-GB 10,000 rpm U320 Universal
Hard Drive (1") |
286716-B22 |
| |
72.8-GB 10,000 rpm U320 Universal
Hard Drive (1") |
286714-B22 |
| |
36.4-GB 10,000 rpm U320 Universal
Hard Drive (1") |
286713-B22 |
| |
72.8-GB 15,000 rpm U320 Universal
Hard Drive (1") |
286778-B22 |
| |
36.4-GB 15,000 rpm U320 Universal
Hard Drive (1") |
286776-B22 |
| |
18.2-GB 15,000 rpm U320 Universal
Hard Drive (1") |
286775-B22 |
| |
Wide Ultra3 SCSI Drives
Non-Hot Plug |
|
| |
36.4-GB Wide Ultra3 SCSI 10,000
rpm Drive (1") |
176497-B21 |
| |
18.2-GB Wide Ultra3 SCSI 10,000
rpm Drive (1") |
142674-B21 |
| |
9.1-GB Wide Ultra3 SCSI 10,000
rpm Drive (1") |
142672-B21 |
| |
Wide Ultra320 Universal
Non-Hot Plug |
|
| |
36-GB U320 10,000 rpm Non-Hot
Plug Hard Drive (1") |
271832-B21 |
| |
NOTE: This is
a list of supported hard disk drives (note that some drives may be discontinued). |
|
|
| Storage Enclosures |
StorageWorks Enclosure
Model 4314T |
190210-001 |
| StorageWorks Enclosure
Model 4314T (Int'l) |
190210-B31 |
| StorageWorks Enclosure
Model 4314T (Japan) |
190210-291 |
| StorageWorks Enclosure
Model 4314R |
190209-001 |
| StorageWorks Enclosure
Model 4314R (Int'l) |
190209-B31 |
| |
StorageWorks Enclosure
Model 4314R (Japan) |
190209-291 |
| |
StorageWorks Enclosure
Model 4354R |
190211-001 |
| |
StorageWorks Enclosure
Model 4354R (Int'l) |
190211-B31 |
| |
StorageWorks Enclosure
Model 4354R (Japan) |
190211-291 |
|
| Related Products |
HP RAID LC2 Controller |
188044-B21 |
| HP RAID LC2 Controller
(Japan) |
188044-291 |
| Compaq Smart Array
5302/32 Controller |
166207-B21 |
| Compaq Smart Array
5302/32 Controller (Japan) |
166207-291 |
| Compaq Smart Array
5302/64 Controller |
124992-B21 |
| Compaq Smart Array
5302/64 Controller (Japan) |
124992-291 |
| Compaq Smart Array
5304/128 Controller |
158939-B21 |
| Compaq Smart Array
5304/128 Controller (Japan) |
158939-291 |
| HP Smart Array 5302/128
Controller |
283552-B21 |
| HP Smart Array 5302/128
Controller (Japan) |
283552-291 |
| |
HP Smart Array 5304/256
Controller |
283551-B21 |
| |
HP Smart Array 5304/256
Controller (Japan) |
283551-291 |
| Smart Array 641 |
| Protocol |
Ultra320 SCSI |
| SCSI Electrical Interface |
Low Voltage Differential (LVD) |
| Drives Supported |
Up to 6 Ultra 320, Ultra3 and
Ultra2 SCSI hard drives |
| SCSI Port Connectors SA-641 |
one internal SCSI port |
| Data Transfer Method |
64-Bit PCI bus-master |
| PCI Bus Speed |
64-bit, 133-MHz PCI-X (1 GB/s
maximum bandwidth) |
| PCI |
3.3 volt CPI slot compatibility
only |
| Simultaneous Drive Transfer
Channels |
Two |
| Channel Transfer Rate |
320 MB/s total; 320 MB/s per channel |
| Software upgradeable Firmware |
Yes |
| Cache Memory |
64 MB of DDR memory used for RAID
and read cache |
| Logical Drives Supported |
32 |
| Maximum Capacity |
880.8 GB (6 X 146.8 GB) |
| Memory Addressing |
64-bit, supporting servers memory
greater than 4 GB |
| RAID Support |
RAID 5 (Distributed Data Guarding) |
|
RAID 1+ 0 (Striping and Mirroring) |
|
RAID 1 (Mirroring) |
|
RAID 0 (Stripping) |
| Upgradeable Firmware |
2-MB Flashable ROM |
| Disk Drive and Enclosure Protocol
Support |
Ultra2, Ultra3, and Ultra320 |
| Dimensions (HxWxD) |
12.3 x 4.2 x 0.6 in/31.24 x 10.7
x 1.5 cm |
| Warranty |
Maximum: The remaining warranty
of the HP server product in which it is installed (to a maximum three-year
limited warranty) |
| |
Minimum: One-year, on-site limited
warranty |
| |
Pre-Failure Warranty: Drives attached
to the Smart Array Controller and monitored under Insight Manager are supported
by a Pre-Failure (replacement) Warranty. For complete details, consult the
HP Support Center or refer to your HP Server Documentation. |
|
| Smart Array 642 |
| Protocol |
Ultra320 SCSI |
| SCSI Electrical Interface |
Low Voltage Differential (LVD) |
| Drives Supported |
Up to 20 (6 internal and 14 external)
Ultra 320, Ultra3 and Ultra2 SCSI hard drives |
| SCSI Port Connectors SA-642 |
One external and one internal
SCSI port |
| Data Transfer Method |
64-Bit PCI bus-master |
| PCI Bus Speed |
64-bit, 133-MHz PCI-X (1 GB/s
maximum bandwidth) |
| PCI |
3.3 volt CPI slot compatibility
only |
| Simultaneous Drive Transfer
Channels |
Two |
| Channel Transfer Rate |
640-MB/s total; 320-MB/s per channel |
| Software upgradeable Firmware |
Yes |
| Cache Memory |
64 MB of DDR memory used for RAID
and read cache |
| Logical Drives Supported |
32 |
| Maximum Capacity |
2.9 TB (20 X 146.8-GB) |
| Memory Addressing |
64-bit, supporting servers memory
greater than 4 GB |
| RAID Support |
RAID 5 (Distributed Data Guarding) |
|
RAID 1+ 0 (Striping and Mirroring) |
|
RAID 1 (Mirroring) |
|
RAID 0 (Stripping) |
| Upgradeable Firmware |
2-MB Flashable ROM |
| Disk Drive and Enclosure Protocol
Support |
Ultra2, Ultra3, and Ultra320 |
| Dimensions (HxWxD) |
12.3 x 4.2 x 0.6 in/31.24 x 10.7
x 1.5 cm |
| Warranty |
Maximum: The remaining warranty
of the HP server product in which it is installed (to a maximum three-year
limited warranty) |
| |
Minimum: One-year, on-site limited
warranty |
| |
Pre-Failure Warranty: Drives attached
to the Smart Array Controller and monitored under Insight Manager are supported
by a Pre-Failure (replacement) Warranty. For complete details, consult the
HP Support Center or refer to your HP Server Documentation. |
|