contents
 Overview      Standard Features      Compatibility      Models      Service and Support, HP Care Pack , and Warranty Information      Options      Technical Specifications line.gif (50 bytes)

Overview

HP Smart Array 641 Controller
HP Smart Array 642 Controller
HP 64MB BBWC Enabler

Smart Array 641 Controller
The new Smart Array 641 Controller (SA-641) is a 64-bit, 133-MHz PCI -X dual SCSI channel PCI array controller for entry level hardware-based fault tolerance. Utilizing a SCSI channel (1 internal) of the SA-641 allows you to configure up to 6 internal hard drives to store up to 880.8 GB of storage. The SA-641 provides high reliability and increased performance over the LC2 controller, thus providing excellent value and lowering the total server ownership cost. In addition, the SA-641 is data compatible with all Ultra 320, Wide Ultra3 and Wide Ultra2 drives, offering an unparalleled degree of investment protection. Designed and integrated with HP entry-level and workgroup ProLiant servers, this product provides worry-free data protection.

Smart Array 642 Controller
The new Smart Array 642 Controller (SA-642) is a 64-bit, 133 MHz PCI-X dual SCSI channel PCI array controller for entry level hardware-based fault tolerance. Utilizing both SCSI channels (1 internal and 1 external) of the SA-642 allows you to configure up to 20 hard drives (6 internal, 14 external) to store up to 2.9TB of storage per PCI slot. The SA-642 provides high reliability and increased performance over the Smart Array 532, thus providing excellent value and lowering the total server ownership cost. In addition, the SA-642 is data compatible with all Ultra 320, Wide Ultra3 and Wide Ultra2 drives, offering an unparalleled degree of investment protection. Designed and integrated with HP entry-level and workgroup ProLiant servers, this product provides worry-free data protection.
The Smart Array 641/642 Controller provides ProLiant DL and ML servers with an entry-level hardware RAID protection for OS and log files, where hardware RAID is needed at an entry-level price point.

64-MB BBWC (Battery-Backed Write Cache) Enabler
The new 64MB BBWC Enabler is a transportable 64MB battery module increasing the total memory of the controller to 128MB for RAID, read cache, and BBWC. The transportability of the battery memory module protects the write cache data from unexpected power loss, system board failure, or controller board failure. Data retained in the write cache will be protected for up to 72 hours, allowing time to restore power, or transport the module to a functioning system board or array controller. The modular design of the battery memory module is transportable between the Smart Array 641 and Smart Array 642 controllers.
64MB BBWC (Battery Backed Write Cache) Enabler allows the 641/642 controllers an option to add transportable BBWC for improved controller performance and increases the total controller memory to 128MB.
291969-B21

128-MB BBWC (Battery-Backed Write Cache) Enabler
The new 128MB BBWC Enabler is a transportable 128MB battery module increasing the total memory of the controller to 192MB for RAID, read cache, and BBWC. The transportability of the battery memory module protects the write cache data from unexpected power loss, system board failure, or controller board failure. Data retained in the write cache will be protected for up to 72 hours, allowing time to restore power, or transport the module to a functioning system board or array controller. The modular design of the battery memory module is transportable between the Smart Array 641 and Smart Array 642 controllers.
128MB BBWC (Battery Backed Write Cache) Enabler allows the 641/642 controllers an option to add transportable BBWC for improved controller performance and increases the total controller memory to 192MB.
351580-B21
contents
 Overview      Standard Features      Compatibility      Models      Service and Support, HP Care Pack , and Warranty Information      Options      Technical Specifications line.gif (50 bytes)

Standard Features

The Smart Array Advantage HP's innovative design and integration work of the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID products. The HP Smart Array family brings an unparalleled return on investment through:
  Data Compatibility Data Compatibility among all models of Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase. Even successive generations of Smart Array controllers understand the data format of other Smart Array Controllers.
  Consistent Configuration and Management Tools All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the HP server storage.
  Universal Hard Drive Form factor is for use across multiple HP ProLiant servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives.
  Pre-Failure Warranty Pre-Failure Warranty means Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center or refer to your HP Server documentation.

Key Features for both Smart Array 641 and Smart Array 642 Controllers
  • Compatibility with all Ultra 320, Ultra3 and Ultra2 LVD family products. In addition, a seamless upgrade to next generation HP high performance and high capacity mainstream Ultra320 Smart Array controllers.
  • Recovery ROM protects against a ROM corruption.
  • Ultra320 SCSI technology delivers high performance and data bandwidth up to 320-MB/s bandwidth per channel.
  • Modular, easy-to-upgrade design lets you optimize performance as needed with the 64MB BBWC Enabler, from 64-MB of memory for RAID and read cache to 128-MB of memory for RAID, read cache, and BBWC.
  • Mix-and-match LVD SCSI compatibility protects your investments and lets you deploy drives as needed.
  • Software consistency among all Smart Array family products: Array Configuration Utility XE (ACU-XE), Array Configuration Utility (ACU), Insight Manager (CIM), Array Diagnostic Utility (ADU) and SmartStart.
  • 64-bit, 133-MHz PCI-X interface boosts bandwidth above 1B/s burst transfer rate over PCI-X bus.
  • 64-bit memory addressing supports servers with greater than 4 GB of memory.
  • 64-MB memory optimizes performance and data throughput.
    NOTE: 64 MB of DDR memory used for RAID and read cache.
  Online Management Features Online Capacity Expansion, Online RAID Level Migration, Online Stripe Size Migration, Online Spares (Global), User Selectable Expand and Rebuild Priority
  Channels
  • SA 641 : Single Channel provide the ability to support up to 6 drives or 880.8GB
  • SA 642 : Dual Channels provide the ability to support up to 20 (6 internal, 14 external) drives or 2.9TB

Key Features for 64MB BBWC Enabler
  • Battery-backed Cache protects cached data in the event of a power outage, server failure or controller failure.
  • 72 hours of battery charge protects the data for an entire weekend.
  • 3 years of battery life.
  • Modular, easy-to-upgrade design lets you optimize performance as needed with the 64MB BBWC Enabler, from 64-MB of memory for RAID and read cache to 128-MB of memory for RAID, read cache, and BBWC.

Data Compatibility

Data compatibility among all models of Smart Array Controllers means customers can instantly upgrade their Smart Array products to get to higher performance, capacity and availability. Unlike competitive products, successive generations of Smart Array products understand the data format of other Smart Array controllers, providing investment protection for your HP storage solution.

Performance

HP's High Performance Architecture sets new boundaries of industry performance expectations!
 
  • Wide Ultra320 SCSI (320 MB/s bandwidth) per channel
  • High-performance 64-bit architecture
  • 64-bit, 133-MHz PCI-X bus (1033 MB/s bandwidth)

Capacity Smart Array 641 Given the internal server storage need for rapid capacity expansion, the SA-641 offers:
 
  • Single SCSI channel support up to 6 internal disk drives
  • Up to 880.8GB of storage per PCI slot
  Smart Array 642 Given the internal server storage need for rapid capacity expansion, the SA-642 offers:
   
  • Dual SCSI channels support up to 20 (6 internal, 14 external) disk drives
  • Up to 2.9 TB of storage per PCI slot

Availability

Provides increased server uptime by providing advanced storage functionality:
 
  • Online RAID Level Migration (between any RAID level)
  • Online Capacity Expansion
  • Logical Drive Capacity Extension
  • Global Online Spare
  • Pre-Failure Warranty

Fault Prevention

The following features offer detection of possible failures before they occur, allowing preventive action to be taken:
 
  • S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at Compaq detects possible hard disk failure before it occurs, allowing replacement of the component before failure occurs.
  • Drive Parameter Tracking monitors drive operational parameters, predicting failure and notifying the administrator.
  • Dynamic Sector Repairing continually performs background surface scans on the hard disk drives during inactive periods and automatically remaps bad sectors, ensuring data integrity.
  • Smart Array Cache Tracking monitors integrity of controller cache, allowing pre-failure preventative maintenance.
  • Environment Tracking for External Storage System: Monitors fan speed and cabinet temperature of ProLiant Storage System and newer HP storage enclosures.

Fault Tolerance

Keeps data available and server running while a failed drive is being replaced; several fault tolerance configurations are supported including:
 
  • Distributed Data Guarding (RAID 5): This allocates parity data across multiple drives and allows simultaneous write operations. It is recommended for up to 14 hard drives.
  • Drive Mirroring (RAID 1, 1+0): This allocates half of the drive array to data and the other half to mirrored data, providing two copies of every file. It is a high-performance RAID.

Fault Recovery

Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure
 
  • Recovery ROM: This new feature provides a unique redundancy feature that protects from a ROM image corruption. A new version of firmware can be flashed to the ROM while the controller maintains the last known working version of firmware. If the firmware becomes corrupt, the controller will revert back to the previous version of firmware and continue operating. This reduces the risk of flashing firmware to the controller.
  • On-Line Spares: Up to two spare drives can be installed prior to drive failure. If a failure occurs, recovery begins with an On-Line Spare and data is reconstructed automatically.
  NOTE: On-Line Spares can only be used with RAID level 1, 1+0, and 5.

Ease of Use Consistency and Upgradability make the Smart Array family unique in the industry:
 
  • GUI based configuration, management and diagnostic software tools
  • Common data format between generations of products
  • Data migration between servers and external storage enclosures
contents
 Overview      Standard Features      Compatibility      Models      Service and Support, HP Care Pack , and Warranty Information      Options      Technical Specifications line.gif (50 bytes)

Compatibility

Servers

For up to date compatibility, please see the following URL for complete Smart Array 641 and Smart Array 642 compatibility and support information.
http://h18006.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html

Operating Systems Microsoft® Windows® 2000 (Server/Adv Server)
Microsoft Windows 2003 (when available)
  Microsoft Windows NT® 4.0
  NetWare 6
  NetWare 5.x
  Linux Red Hat 2.1 Advanced Server
  Linux Red Hat 7.3
  Linux Red Hat 8.0
  SuSE SLES 7
  IBM OS/2 Warp Server for ebusiness
  SCO Open Server 5.05, 5.0.7 (to be released 1Q, 03)
  SCO UnixWare 7.1.1
  SCO Open UNIX® 8
  SCO UnixWare 7.1.3 (to be released 4Q, 02)

Software Suite All Smart Array products share a common set of configuration, management and diagnostic tools, including Array Configuration Utility XE (ACU-XE), Array Configuration Utility (ACU), Array Diagnostic Utility (ADU), and Insight Manager. This software consistency of tools reduces the cost of training for each successive generation of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain the HP server storage.
  Insight Manager
 
  • Powerful server and server options/storage manager tool
  • Monitors over 1200 server parameters
  • Configuration/Diagnostic Utilities
  • HP Array Configuration Utility (ACU)
  • Powerful Web based configuration utility for all Smart Array controllers
  • Provides a graphical view of HP drive array configurations
  • Allows for management of multiple arrays over a secure internet connection from anywhere in the world
  • Easy to use Wizards for configuration
  • Runs online on Windows NT v4.0, Windows 2000 and NetWare
  • HP Options ROM Configuration for Arrays (ORCA)
  • Rapid configuration during initial install of the OS
  • HP Array Diagnostic Utility (ADU)
  • Powerful diagnostic utility for all Smart Array controllers
contents
 Overview      Standard Features      Compatibility      Models      Service and Support, HP Care Pack , and Warranty Information      Options      Technical Specifications line.gif (50 bytes)

Models

Smart Array 641 Controller
291966-B21
  Features  
    Single SCSI channel (1 internal)  
    ProLiant Integration  
    Reliability  
    Ultra320 SCSI  
    64-MB memory for code, transfer buffers and read cache  
    64-bit Architecture  
    64-bit/133-Mhz PCI-X Bus Design  
    Online Capacity Expansion  
    Online RAID level Migration  

Smart Array 642 Controller
291967-B21
  Features  
    Dual SCSI channels (1 internal/1 external)  
    ProLiant Integration  
    Reliability  
    Ultra320 SCSI  
    64-MB memory for code, transfer buffers and read cache  
    64-bit Architecture  
    64-bit/133-Mhz PCI-X Bus Design  
    Online Capacity Expansion  
    Online RAID level Migration  

64MB BBWC Enabler
291969-B21
  Features  
    64 MB battery/memory module for a total of 128MB of memory for RAID, read cache and battery backed write cache (BBWC)  
    72 hours of battery charge  
    3 year battery life  

128MB BBWC Enabler
351580-B21
  Features  
    128 MB battery/memory module for a total of 192MB of memory for RAID, read cache and battery backed write cache (BBWC)  
    72 hours of battery charge  
    3 year battery life  
contents
 Overview      Standard Features      Compatibility      Models      Service and Support, HP Care Pack , and Warranty Information      Options      Technical Specifications line.gif (50 bytes)

Service and Support, HP Care Pack , and Warranty Information

Software Product Services
Standalone telephone support
Rights to new license version
  Media and documentation updates

Hardware Product Services Installation services
On-site maintenance (includes warranty support)
  Response time upgrades during the warranty period
  Post-warranty coverage
  RAID setup and performance consulting via statement of work
  For additional hardware installation and maintenance information, please refer to the URL listed below:
http://www.hp.com/hps/hardware/

Warranty Upgrade Options Response - Upgrade on-site response from next business day to same day 4 hours
Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days
  Duration - Select duration of coverage for a period of 1, 3, or 5 years

HP Care Pack Information Sample part numbers:
3 year, uplift to 5 x 9, Next Day Response
FM-**XHW-36
3 year, uplift to 5 x 9, 4-hour Response
FM-**4HR-36
3 year, uplift to 7 x 24, 4-hour Response
FM-**724-36
** Represents a two-digit, product-specific code
  HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage.
  HP Care Pack is not available for less than the product's warranty duration.
  HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required.
  HP Care Pack services are prepaid.
  For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL http://www.hp.com/hps/carepack/
contents
 Overview      Standard Features      Compatibility      Models      Service and Support, HP Care Pack , and Warranty Information      Options      Technical Specifications line.gif (50 bytes)

Options

Hard Drives Wide Ultra3 SCSI Universal Drives – Hot Plug  
36.4-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") 232916-B22
18.2-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") 188122-B22
9.1-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") 188120-B22
72.8-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 232432-B22
36.4-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 176496-B22
  18.2-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 142673-B22
  9.1-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 142671-B22
  36-GB Wide Ultra3 SCSI 10,000 rpm Drives (1"), 10 pack 232617-B21
  18-GB Wide Ultra3 SCSI 10,000 rpm Drives (1"), 10 pack 202352-B21
  Wide Ultra320 SCSI Drives – Hot Plug  
  146.8-GB 10,000 rpm U320 Universal Hard Drive (1") 286716-B22
  72.8-GB 10,000 rpm U320 Universal Hard Drive (1") 286714-B22
  36.4-GB 10,000 rpm U320 Universal Hard Drive (1") 286713-B22
  72.8-GB 15,000 rpm U320 Universal Hard Drive (1") 286778-B22
  36.4-GB 15,000 rpm U320 Universal Hard Drive (1") 286776-B22
  18.2-GB 15,000 rpm U320 Universal Hard Drive (1") 286775-B22
  Wide Ultra3 SCSI Drives – Non-Hot Plug  
  36.4-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 176497-B21
  18.2-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 142674-B21
  9.1-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") 142672-B21
  Wide Ultra320 – Universal Non-Hot Plug  
  36-GB U320 10,000 rpm Non-Hot Plug Hard Drive (1") 271832-B21
  NOTE: This is a list of supported hard disk drives (note that some drives may be discontinued).  

Software StorageWorks Virtual Replicator  
License & Media (CD-ROM) 191802-B21
NOTE: For additional Virtual Replicator ordering information refer to http://www.compaq.com/products/StorageWorks/swvr/swvrorderinfo.html.  

Universal Hot Plug Tape Drives AIT 50 GB, Hot Plug (Carbon) 215487-B21
AIT 35 GB, LVD Hot Plug (Carbon) 216886-B21
20/40-GB DAT, Hot Plug (Carbon) 215488-B21

Storage Enclosures StorageWorks Enclosure Model 4314T 190210-001
StorageWorks Enclosure Model 4314R 190209-001
  StorageWorks Enclosure Model 4354R 190211-001

Related Products HP RAID LC2 Controller 188044-B21
Compaq Smart Array 5302/32 Controller 166207-B21
Compaq Smart Array 5302/64 Controller 124992-B21
Compaq Smart Array 5304/128 Controller 158939-B21
HP Smart Array 5302/128 Controller 283552-B21
  HP Smart Array 5304/256 Controller 283551-B21
contents
 Overview      Standard Features      Compatibility      Models      Service and Support, HP Care Pack , and Warranty Information      Options      Technical Specifications line.gif (50 bytes)

Technical Specifications

Smart Array 641
Protocol Ultra320 SCSI
SCSI Electrical Interface Low Voltage Differential (LVD)
Drives Supported Up to 6 Ultra 320, Ultra3 and Ultra2 SCSI hard drives
SCSI Port Connectors SA-641 one internal SCSI port
Data Transfer Method 64-Bit PCI bus-master
PCI Bus Speed 64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth)
PCI 3.3 volt CPI slot compatibility only
Simultaneous Drive Transfer Channels Two
Channel Transfer Rate 320 MB/s total; 320 MB/s per channel
Software upgradeable Firmware Yes
Cache Memory 64 MB of DDR memory used for RAID and read cache
Logical Drives Supported 32
Maximum Capacity 880.8 GB (6 X 146.8 GB)
Memory Addressing 64-bit, supporting servers memory greater than 4 GB
RAID Support RAID 5 (Distributed Data Guarding)
RAID 1+ 0 (Striping and Mirroring)
RAID 1 (Mirroring)
RAID 0 (Stripping)
Upgradeable Firmware 2-MB Flashable ROM
Disk Drive and Enclosure Protocol Support Ultra2, Ultra3, and Ultra320
Dimensions (HxWxD) 12.3 x 4.2 x 0.6 in/31.24 x 10.7 x 1.5 cm
Warranty Maximum: The remaining warranty of the HP server product in which it is installed (to a maximum three-year limited warranty)
  Minimum: One-year, on-site limited warranty
  Pre-Failure Warranty: Drives attached to the Smart Array Controller and monitored under Insight Manager are supported by a Pre-Failure (replacement) Warranty. For complete details, consult the HP Support Center or refer to your HP Server Documentation.

Smart Array 642
Protocol Ultra320 SCSI
SCSI Electrical Interface Low Voltage Differential (LVD)
Drives Supported Up to 20 (6 internal and 14 external) Ultra 320, Ultra3 and Ultra2 SCSI hard drives
SCSI Port Connectors SA-642 One external and one internal SCSI port
Data Transfer Method 64-Bit PCI bus-master
PCI Bus Speed 64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth)
PCI 3.3 volt CPI slot compatibility only
Simultaneous Drive Transfer Channels Two
Channel Transfer Rate 640-MB/s total; 320-MB/s per channel
Software upgradeable Firmware Yes
Cache Memory 64 MB of DDR memory used for RAID and read cache
Logical Drives Supported 32
Maximum Capacity 2.9 TB (20 X 146.8-GB)
Memory Addressing 64-bit, supporting servers memory greater than 4 GB
RAID Support RAID 5 (Distributed Data Guarding)
RAID 1+ 0 (Striping and Mirroring)
RAID 1 (Mirroring)
RAID 0 (Stripping)
Upgradeable Firmware 2-MB Flashable ROM
Disk Drive and Enclosure Protocol Support Ultra2, Ultra3, and Ultra320
Dimensions (HxWxD) 12.3 x 4.2 x 0.6 in/31.24 x 10.7 x 1.5 cm
Warranty Maximum: The remaining warranty of the HP server product in which it is installed (to a maximum three-year limited warranty)
  Minimum: One-year, on-site limited warranty
  Pre-Failure Warranty: Drives attached to the Smart Array Controller and monitored under Insight Manager are supported by a Pre-Failure (replacement) Warranty. For complete details, consult the HP Support Center or refer to your HP Server Documentation.

64-MB BBWC Enabler
Cache Memory 64 MB of DDR memory for RAID, read cache, and BBWC: ECC protection, battery-backed, and removable
Cache Batteries Up to 3 days of battery life, removable for easy replacement
Dimensions (HxWxD) 3.5 x 1.8 x 0.54 in/8.89 x 4.6 x 1.37 cm

128-MB BBWC Enabler
Cache Memory 128 MB of DDR memory for RAID, read cache, and BBWC: ECC protection, battery-backed, and removable
Cache Batteries Up to 3 days of battery life, removable for easy replacement
Dimensions (HxWxD) 3.5 X 1.8 X .54 in/8.89 x 4.6 x 1.37 cm

© Copyright 2003-2004 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

   DA-11563 - U.S. - Version 7 - August 2, 2004