Overview
|
HP Smart Array 641 Controller |
| Smart Array 641 Controller |
The new Smart Array 641 Controller (SA-641) is a 64-bit,
133-MHz PCI -X dual SCSI channel PCI array controller for entry level
hardware-based fault tolerance. Utilizing a SCSI channel (1 internal)
of the SA-641 allows you to configure up to 6 internal hard drives to
store up to 880.8 GB of storage. The SA-641 provides high reliability
and increased performance over the LC2 controller, thus providing excellent
value and lowering the total server ownership cost. In addition, the SA-641
is data compatible with all Ultra 320, Wide Ultra3 and Wide Ultra2 drives,
offering an unparalleled degree of investment protection. Designed and
integrated with HP entry-level and workgroup ProLiant servers, this product
provides worry-free data protection.
|
|
|
|
| Smart Array 642 Controller |
The new Smart Array 642 Controller (SA-642) is a 64-bit,
133 MHz PCI-X dual SCSI channel PCI array controller for entry level hardware-based
fault tolerance. Utilizing both SCSI channels (1 internal and 1 external)
of the SA-642 allows you to configure up to 20 hard drives (6 internal,
14 external) to store up to 2.9TB of storage per PCI slot. The SA-642
provides high reliability and increased performance over the Smart Array
532, thus providing excellent value and lowering the total server ownership
cost. In addition, the SA-642 is data compatible with all Ultra 320, Wide
Ultra3 and Wide Ultra2 drives, offering an unparalleled degree of investment
protection. Designed and integrated with HP entry-level and workgroup
ProLiant servers, this product provides worry-free data protection.
The Smart Array 641/642 Controller provides ProLiant DL and ML servers with an entry-level hardware RAID protection for OS and log files, where hardware RAID is needed at an entry-level price point. |
|
|
|
| 64-MB BBWC (Battery-Backed Write Cache) Enabler |
The new 64MB BBWC Enabler is a transportable 64MB battery
module increasing the total memory of the controller to 128MB for RAID,
read cache, and BBWC. The transportability of the battery memory module
protects the write cache data from unexpected power loss, system board
failure, or controller board failure. Data retained in the write cache
will be protected for up to 72 hours, allowing time to restore power,
or transport the module to a functioning system board or array controller.
The modular design of the battery memory module is transportable between
the Smart Array 641 and Smart Array 642 controllers.
64MB BBWC (Battery Backed Write Cache) Enabler allows the 641/642 controllers an option to add transportable BBWC for improved controller performance and increases the total controller memory to 128MB. |
291969-B21
|
|
|
||
| 128-MB BBWC (Battery-Backed Write Cache) Enabler |
The new 128MB BBWC Enabler is a transportable 128MB battery
module increasing the total memory of the controller to 192MB for RAID,
read cache, and BBWC. The transportability of the battery memory module
protects the write cache data from unexpected power loss, system board
failure, or controller board failure. Data retained in the write cache
will be protected for up to 72 hours, allowing time to restore power,
or transport the module to a functioning system board or array controller.
The modular design of the battery memory module is transportable between
the Smart Array 641 and Smart Array 642 controllers.
128MB BBWC (Battery Backed Write Cache) Enabler allows the 641/642 controllers an option to add transportable BBWC for improved controller performance and increases the total controller memory to 192MB. |
351580-B21
|
|
|
Standard Features
| The Smart Array Advantage | HP's innovative design and integration work of the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID products. The HP Smart Array family brings an unparalleled return on investment through: | |
| Data Compatibility | Data Compatibility among all models of Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase. Even successive generations of Smart Array controllers understand the data format of other Smart Array Controllers. | |
| Consistent Configuration and Management Tools | All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the HP server storage. | |
| Universal Hard Drive | Form factor is for use across multiple HP ProLiant servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives. | |
| Pre-Failure Warranty | Pre-Failure Warranty means Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center or refer to your HP Server documentation. | |
|
|
||
| Key Features for both Smart Array 641 and Smart Array 642 Controllers |
|
|
| Online Management Features | Online Capacity Expansion, Online RAID Level Migration, Online Stripe Size Migration, Online Spares (Global), User Selectable Expand and Rebuild Priority | |
| Channels |
|
|
|
|
||
| Key Features for 64MB BBWC Enabler |
|
|
|
|
|
Data Compatibility |
Data compatibility among all models of Smart Array Controllers means customers can instantly upgrade their Smart Array products to get to higher performance, capacity and availability. Unlike competitive products, successive generations of Smart Array products understand the data format of other Smart Array controllers, providing investment protection for your HP storage solution. | ||
|
|
|||
|
Performance |
HP's High Performance Architecture sets new boundaries of industry performance expectations! | ||
|
|||
|
|
|||
| Capacity | Smart Array 641 | Given the internal server storage need for rapid capacity expansion, the SA-641 offers: | ||
|
||||
| Smart Array 642 | Given the internal server storage need for rapid capacity expansion, the SA-642 offers: | |||
|
||||
|
|
||||
|
Availability |
Provides increased server uptime by providing advanced storage functionality: | ||
|
|||
|
|
|||
|
Fault Prevention |
The following features offer detection of possible failures before they occur, allowing preventive action to be taken: | ||
|
|||
|
|
|||
|
Fault Tolerance |
Keeps data available and server running while a failed drive is being replaced; several fault tolerance configurations are supported including: | ||
|
|||
|
|
|||
|
Fault Recovery |
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure | ||
|
|||
| NOTE: On-Line Spares can only be used with RAID level 1, 1+0, and 5. | |||
|
|
|||
| Ease of Use | Consistency and Upgradability make the Smart Array family unique in the industry: | |
|
||
|
|
Compatibility
|
Servers |
For up to date compatibility, please see
the following URL for complete Smart Array 641 and Smart Array 642 compatibility
and support information. http://h18006.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html |
|
|
|
| Operating Systems | Microsoft® Windows® 2000 (Server/Adv Server) | |
| Microsoft Windows 2003 (when available) | ||
| Microsoft Windows NT® 4.0 | ||
| NetWare 6 | ||
| NetWare 5.x | ||
| Linux Red Hat 2.1 Advanced Server | ||
| Linux Red Hat 7.3 | ||
| Linux Red Hat 8.0 | ||
| SuSE SLES 7 | ||
| IBM OS/2 Warp Server for ebusiness | ||
| SCO Open Server 5.05, 5.0.7 (to be released 1Q, 03) | ||
| SCO UnixWare 7.1.1 | ||
| SCO Open UNIX® 8 | ||
| SCO UnixWare 7.1.3 (to be released 4Q, 02) | ||
|
|
||
| Software Suite | All Smart Array products share a common set of configuration, management and diagnostic tools, including Array Configuration Utility XE (ACU-XE), Array Configuration Utility (ACU), Array Diagnostic Utility (ADU), and Insight Manager. This software consistency of tools reduces the cost of training for each successive generation of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain the HP server storage. | |
| Insight Manager | ||
|
||
|
|
Models
| Smart Array 641 Controller |
291966-B21
|
||
| Features | |||
| Single SCSI channel (1 internal) | |||
| ProLiant Integration | |||
| Reliability | |||
| Ultra320 SCSI | |||
| 64-MB memory for code, transfer buffers and read cache | |||
| 64-bit Architecture | |||
| 64-bit/133-Mhz PCI-X Bus Design | |||
| Online Capacity Expansion | |||
| Online RAID level Migration | |||
|
|
|||
| Smart Array 642 Controller |
291967-B21
|
||
| Features | |||
| Dual SCSI channels (1 internal/1 external) | |||
| ProLiant Integration | |||
| Reliability | |||
| Ultra320 SCSI | |||
| 64-MB memory for code, transfer buffers and read cache | |||
| 64-bit Architecture | |||
| 64-bit/133-Mhz PCI-X Bus Design | |||
| Online Capacity Expansion | |||
| Online RAID level Migration | |||
|
|
|||
| 64MB BBWC Enabler |
291969-B21
|
||
| Features | |||
| 64 MB battery/memory module for a total of 128MB of memory for RAID, read cache and battery backed write cache (BBWC) | |||
| 72 hours of battery charge | |||
| 3 year battery life | |||
|
|
|||
| 128MB BBWC Enabler |
351580-B21
|
||
| Features | |||
| 128 MB battery/memory module for a total of 192MB of memory for RAID, read cache and battery backed write cache (BBWC) | |||
| 72 hours of battery charge | |||
| 3 year battery life | |||
|
|
Service and Support, HP Care Pack , and Warranty Information
| Software Product Services |
Standalone telephone support
|
| Rights to new license version | |
| Media and documentation updates | |
|
|
|
| Hardware Product Services | Installation services |
| On-site maintenance (includes warranty support) | |
| Response time upgrades during the warranty period | |
| Post-warranty coverage | |
| RAID setup and performance consulting via statement of work | |
| For additional hardware installation
and maintenance information, please refer to the URL listed below: http://www.hp.com/hps/hardware/ |
|
|
|
|
| Warranty Upgrade Options | Response - Upgrade on-site response from next business day to same day 4 hours |
| Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days | |
| Duration - Select duration of coverage for a period of 1, 3, or 5 years | |
|
|
|
| HP Care Pack Information | Sample part numbers: | |
| 3 year, uplift to 5 x 9, Next Day Response |
FM-**XHW-36
|
|
| 3 year, uplift to 5 x 9, 4-hour Response |
FM-**4HR-36
|
|
| 3 year, uplift to 7 x 24, 4-hour Response |
FM-**724-36
|
|
| ** Represents a two-digit, product-specific code | ||
| HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. | ||
| HP Care Pack is not available for less than the product's warranty duration. | ||
| HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required. | ||
| HP Care Pack services are prepaid. | ||
| For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL http://www.hp.com/hps/carepack/ | ||
|
|
Options
| Hard Drives | Wide Ultra3 SCSI Universal Drives Hot Plug | ||
| 36.4-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") | 232916-B22 | ||
| 18.2-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") | 188122-B22 | ||
| 9.1-GB Wide Ultra3 SCSI 15,000 rpm Drive (1") | 188120-B22 | ||
| 72.8-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 232432-B22 | ||
| 36.4-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 176496-B22 | ||
| 18.2-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 142673-B22 | ||
| 9.1-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 142671-B22 | ||
| 36-GB Wide Ultra3 SCSI 10,000 rpm Drives (1"), 10 pack | 232617-B21 | ||
| 18-GB Wide Ultra3 SCSI 10,000 rpm Drives (1"), 10 pack | 202352-B21 | ||
| Wide Ultra320 SCSI Drives Hot Plug | |||
| 146.8-GB 10,000 rpm U320 Universal Hard Drive (1") | 286716-B22 | ||
| 72.8-GB 10,000 rpm U320 Universal Hard Drive (1") | 286714-B22 | ||
| 36.4-GB 10,000 rpm U320 Universal Hard Drive (1") | 286713-B22 | ||
| 72.8-GB 15,000 rpm U320 Universal Hard Drive (1") | 286778-B22 | ||
| 36.4-GB 15,000 rpm U320 Universal Hard Drive (1") | 286776-B22 | ||
| 18.2-GB 15,000 rpm U320 Universal Hard Drive (1") | 286775-B22 | ||
| Wide Ultra3 SCSI Drives Non-Hot Plug | |||
| 36.4-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 176497-B21 | ||
| 18.2-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 142674-B21 | ||
| 9.1-GB Wide Ultra3 SCSI 10,000 rpm Drive (1") | 142672-B21 | ||
| Wide Ultra320 Universal Non-Hot Plug | |||
| 36-GB U320 10,000 rpm Non-Hot Plug Hard Drive (1") | 271832-B21 | ||
| NOTE: This is a list of supported hard disk drives (note that some drives may be discontinued). | |||
|
|
|||
| Software | StorageWorks Virtual Replicator | |||
| License & Media (CD-ROM) | 191802-B21 | |||
| NOTE: For additional Virtual Replicator ordering information refer to http://www.compaq.com/products/StorageWorks/swvr/swvrorderinfo.html. | ||||
|
|
||||
| Universal Hot Plug Tape Drives | AIT 50 GB, Hot Plug (Carbon) | 215487-B21 | ||
| AIT 35 GB, LVD Hot Plug (Carbon) | 216886-B21 | |||
| 20/40-GB DAT, Hot Plug (Carbon) | 215488-B21 | |||
|
|
||||
| Storage Enclosures | StorageWorks Enclosure Model 4314T | 190210-001 | ||
| StorageWorks Enclosure Model 4314R | 190209-001 | |||
| StorageWorks Enclosure Model 4354R | 190211-001 | |||
|
|
||||
| Related Products | HP RAID LC2 Controller | 188044-B21 | |
| Compaq Smart Array 5302/32 Controller | 166207-B21 | ||
| Compaq Smart Array 5302/64 Controller | 124992-B21 | ||
| Compaq Smart Array 5304/128 Controller | 158939-B21 | ||
| HP Smart Array 5302/128 Controller | 283552-B21 | ||
| HP Smart Array 5304/256 Controller | 283551-B21 | ||
|
|
Technical Specifications
| Smart Array 641 | ||
| Protocol | Ultra320 SCSI | |
| SCSI Electrical Interface | Low Voltage Differential (LVD) | |
| Drives Supported | Up to 6 Ultra 320, Ultra3 and Ultra2 SCSI hard drives | |
| SCSI Port Connectors SA-641 | one internal SCSI port | |
| Data Transfer Method | 64-Bit PCI bus-master | |
| PCI Bus Speed | 64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth) | |
| PCI | 3.3 volt CPI slot compatibility only | |
| Simultaneous Drive Transfer Channels | Two | |
| Channel Transfer Rate | 320 MB/s total; 320 MB/s per channel | |
| Software upgradeable Firmware | Yes | |
| Cache Memory | 64 MB of DDR memory used for RAID and read cache | |
| Logical Drives Supported | 32 | |
| Maximum Capacity | 880.8 GB (6 X 146.8 GB) | |
| Memory Addressing | 64-bit, supporting servers memory greater than 4 GB | |
| RAID Support | RAID 5 (Distributed Data Guarding) | |
| RAID 1+ 0 (Striping and Mirroring) | ||
| RAID 1 (Mirroring) | ||
| RAID 0 (Stripping) | ||
| Upgradeable Firmware | 2-MB Flashable ROM | |
| Disk Drive and Enclosure Protocol Support | Ultra2, Ultra3, and Ultra320 | |
| Dimensions (HxWxD) | 12.3 x 4.2 x 0.6 in/31.24 x 10.7 x 1.5 cm | |
| Warranty | Maximum: The remaining warranty of the HP server product in which it is installed (to a maximum three-year limited warranty) | |
| Minimum: One-year, on-site limited warranty | ||
| Pre-Failure Warranty: Drives attached to the Smart Array Controller and monitored under Insight Manager are supported by a Pre-Failure (replacement) Warranty. For complete details, consult the HP Support Center or refer to your HP Server Documentation. | ||
|
|
||
| Smart Array 642 | ||
| Protocol | Ultra320 SCSI | |
| SCSI Electrical Interface | Low Voltage Differential (LVD) | |
| Drives Supported | Up to 20 (6 internal and 14 external) Ultra 320, Ultra3 and Ultra2 SCSI hard drives | |
| SCSI Port Connectors SA-642 | One external and one internal SCSI port | |
| Data Transfer Method | 64-Bit PCI bus-master | |
| PCI Bus Speed | 64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth) | |
| PCI | 3.3 volt CPI slot compatibility only | |
| Simultaneous Drive Transfer Channels | Two | |
| Channel Transfer Rate | 640-MB/s total; 320-MB/s per channel | |
| Software upgradeable Firmware | Yes | |
| Cache Memory | 64 MB of DDR memory used for RAID and read cache | |
| Logical Drives Supported | 32 | |
| Maximum Capacity | 2.9 TB (20 X 146.8-GB) | |
| Memory Addressing | 64-bit, supporting servers memory greater than 4 GB | |
| RAID Support | RAID 5 (Distributed Data Guarding) | |
| RAID 1+ 0 (Striping and Mirroring) | ||
| RAID 1 (Mirroring) | ||
| RAID 0 (Stripping) | ||
| Upgradeable Firmware | 2-MB Flashable ROM | |
| Disk Drive and Enclosure Protocol Support | Ultra2, Ultra3, and Ultra320 | |
| Dimensions (HxWxD) | 12.3 x 4.2 x 0.6 in/31.24 x 10.7 x 1.5 cm | |
| Warranty | Maximum: The remaining warranty of the HP server product in which it is installed (to a maximum three-year limited warranty) | |
| Minimum: One-year, on-site limited warranty | ||
| Pre-Failure Warranty: Drives attached to the Smart Array Controller and monitored under Insight Manager are supported by a Pre-Failure (replacement) Warranty. For complete details, consult the HP Support Center or refer to your HP Server Documentation. | ||
|
|
||
| 64-MB BBWC Enabler | ||
| Cache Memory | 64 MB of DDR memory for RAID, read cache, and BBWC: ECC protection, battery-backed, and removable | |
| Cache Batteries | Up to 3 days of battery life, removable for easy replacement | |
| Dimensions (HxWxD) | 3.5 x 1.8 x 0.54 in/8.89 x 4.6 x 1.37 cm | |
|
|
||
| 128-MB BBWC Enabler | ||
| Cache Memory | 128 MB of DDR memory for RAID, read cache, and BBWC: ECC protection, battery-backed, and removable | |
| Cache Batteries | Up to 3 days of battery life, removable for easy replacement | |
| Dimensions (HxWxD) | 3.5 X 1.8 X .54 in/8.89 x 4.6 x 1.37 cm | |
|
|
||
| © Copyright 2003-2004 Hewlett-Packard
Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |