Overview
|
HP Smart Array 6400 Controller |
| The Smart Array 6400 high performance Ultra320,
PCI-X controller family provides maximum performance, flexibility, and reliable
data protection for HP ProLiant servers, through its unique modular design
and support for Advanced Data Guarding (RAID ADG). This new generation performance
Smart Array controller again raises the standards of performance, introducing
Double Data Rate (DDR) battery-backed write cache architecture and a new
RAID engine.
Designed and tested with industry standard ProLiant Servers for greater reliability, this controller is ideal for workgroup and departmental servers. And like other Smart Array controllers, the SA-6400 features complete data compatibility with previous generation's Smart Array controllers for easy data migration from server to server and for controller upgradeability. |
|
|
| Models | Smart Array 6402/128 Controller |
273915-B21
|
| Smart Array 6404/256 Controller |
273914-B21
|
|
|
|
||
| HP Smart Array 6400 Controller Feature List |
|
|
|
|
| Key Features |
|
|
|
|
Product Highlights
| The Smart Array Advantage |
HP's innovative design and integration work of the Smart
Array family of products creates customer value that is unmatched in the
industry. Use of Smart Array products across multiple applications results
in a much lower Total Cost of Ownership (TCO) than any other server storage
RAID product. The HP Smart Array family brings an unparalleled return
on investment through:
|
| Data Compatibility among all models of Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase. Even successive generations of Smart Array controllers understand the data format of other Smart Array Controllers. | |
| Consistent Configuration and Management Tools. All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the HP server storage. | |
| Universal Hard Drive form factor is for use across multiple HP servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives. | |
| Pre-Failure Warranty means HP Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center or refer to your HP Server documentation. | |
|
|
|
| Performance |
HP's new high-performance architecture sets new boundaries of industry performance expectations!
|
|
|
|
| Capacity |
Given the need for rapid capacity expansion, the SA-6400 offers:
|
|
|
|
| Availability |
Provides increased server uptime by providing advanced storage functionality:
|
|
|
|
| Fault Prevention |
The following features offer detection of possible failures before they occur, allowing preventive action to be taken:
|
|
|
|
| Fault Tolerance |
Keeps data available and server running while a failed drive is being replaced; several fault tolerance configurations are supported including:
|
|
|
|
| Fault Recovery |
Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure:
|
|
|
|
| Ease of Use |
Consistency and Upgradeability make the Smart Array family unique in the industry:
|
|
|
|
| Servers Compatibility |
For up to date compatibility, please see the following
URL for complete Smart Array 6400 compatibility and support information:
http://h18006.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html |
|
|
|
| Operating Systems Compatibility |
Microsoft® Windows® NT® 4.0, 2000
NOTE: NT 4.0 support for U320 Expansion Module for the SA-6402 will not be available at launch. |
| Windows Server 2003 | |
| Novell NetWare 5.x, 6 | |
| SCO UnixWare® 7.1.1, 7.1.3 | |
| SCO Unix® 5.0.6a, 5.0.7 | |
| Red Hat Enterprise Linux | |
| SUSE Linux Enterprise Server | |
| NOTE: For more Linux OS support & certification information, please visit our the ProLiant & BladeSystem Server Linux matrix: http://h18004.www1.hp.com/products/servers/linux/hpLinuxcert.html | |
|
|
|
| Configuration/ Diagnostic Utilities |
|
|
|
|
| Software Suite | All Smart Array products share a common set of configuration, management and diagnostic tools, including Array Configuration Utility (ACU), Array Diagnostic Utility (ADU), and Insight Manager. This software consistency of tools reduces the cost of training for each successive generation of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain the HP server storage. | |
| Systems Insight Manager |
|
|
|
|
Service and Support, HP Care Pack, and Warranty Information
| Available Software Product Services |
Standalone telephone support
|
| Rights to new license version | |
| Media and documentation updates | |
|
|
|
| Available Hardware Product Services | Installation services |
| On-site maintenance (includes warranty support) | |
| Response time upgrades during the warranty period | |
| Post-warranty coverage | |
| RAID setup and performance consulting via statement of work | |
| For additional hardware installation and maintenance information, please refer to the URL listed below: http://www.hp.com/hps/ | |
|
|
|
| Warranty Upgrade Options | Response Upgrade on-site response from next business day to same day 4 hours |
| Coverage Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days | |
| Duration Select duration of coverage for a period of 1, 3, or 5 years | |
|
|
|
| Warranty Upgrade Options | HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. | |
| HP Care Pack is not available for less than the product's warranty duration. | ||
| HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required. | ||
| HP Care Pack services are prepaid. | ||
| For additional HP
Care Pack (hardware & software) information, as well as orderable part
numbers, please refer to the URL http://www.hp.com/hps/. NOTE: HP Care Packs are not sold with the server they are not sold with the Option Card. |
||
|
|
Options
| NOTE: This is a list of supported options. Some options may be discontinued. | ||
| Controller Upgrade Options | Ultra320 Expansion Module for SA-6402 |
273911-B21 |
| 512 MB Battery-Backed Cache Upgrade |
372538-B21 | |
|
| ||
| Disk Drive Enclosures | HP StorageWorks Modular
Smart Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies. |
302969-001
|
| HP StorageWorks Modular
Smart Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies. |
302970-001
|
|
| StorageWorks Enclosure 4314T |
190210-001
|
|
| StorageWorks Enclosure 4314R |
190209-001
|
|
| StorageWorks Enclosure 4354R |
190211-001
|
|
|
|
||
| Hard Drives | Ultra320 - Universal Hot Plug | |
| HP 300GB U320 10K
Universal HDD |
350964-B22
|
|
| HP 146GB U320 10K
Universal HDD |
286716-B22
|
|
| HP 72GB U320 10K
Universal HDD |
286714-B22
|
|
| HP 300GB U320 15K Universal HDD |
411089-B22
|
|
| HP 146GB U320 15K
Universal HDD |
286713-B22
|
|
| HP 72GB U320 15K Universal HDD |
286778-B22
|
|
| HP 36GB U320 15K Universal HDD |
286776-B22
|
|
| NOTE:
Please see the Hard Drive QuickSpecs for Technical Specifications such
as capacity, height, width, interface, transfer rate, seek time, physical
configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html |
||
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320 transfer rates. | ||
|
|
||
| Universal Hot Plug Tape Drives | HP StorageWorks DAT 40 SCSI Hot-plug Tape Drive (Carbon) |
Q1546A
|
| HP StorageWorks DAT 72 SCSI Hot-plug Tape Drive (Carbon) |
Q1529A
|
|
|
Family Information
| This is a brief overview and comparison of the Smart Array family of PCI RAID controllers. |
|
Smart Array 6402/6404
|
Smart Array 5312
|
Smart Array 5302/5304
|
|
| Introduction Date |
June/September 2003
|
April 2002
|
July 2000
|
| SCSI Protocols Supported |
Ultra320, Ultra3, Ultra2
|
Ultra3, Ultra2
|
Ultra3, Ultra2,
Wide-Ultra |
| Maximum Channel Transfer Rate (MB/s) |
1280 total
320 per channel |
320 total
160 per channel |
640 total
160 per channel |
| Channels |
2, 4
|
2
|
2, 4
|
| SCSI Ports (external/internal) |
2 channel model: 2/2
4 channel model: 4/2 |
2/2
|
2 channel model: 2/2
4 channel model: 4/2 |
| Maximum Drives |
56*
|
28*
|
56*
|
| Cache |
128-, 256-, 512-MB
read-write |
128-MB read-write
|
256-, 128-, 64- or 32-MB
read-write |
| Battery-backed, Removable Cache |
Yes, Redundant,
Replaceable Batteries |
Yes, Redundant
Replaceable Batteries |
Yes, Redundant
Replaceable Batteries |
| Upgradeable Cache |
Yes
|
Yes
|
Yes
|
| Recovery ROM |
Yes
|
Yes
|
Yes
|
| RAID Support |
0,1,1+0,5,
Advanced Data Guarding |
0,1,1+0,5
|
0,1,1+0,5,
Advanced Data Guarding** |
| Configuration Tool(s) |
ACU
ORCA |
ACU
ORCA |
ACU
ORCA |
| Management and Diagnostic Tools |
IM
ADU |
IM
ADU |
IM
ADU |
| Maximum Volumes |
32
|
32
|
32
|
| Drive Roaming |
Yes
|
Yes
|
Yes
|
| Online Expansion |
Yes
|
Yes
|
Yes
|
| Online & Offline Configuration |
Yes
|
Yes
|
Yes
|
| Logical Drive Extension |
Yes
|
Yes
|
Yes
|
| Stripe Set Migration |
Yes
|
Yes
|
Yes
|
| RAID Level Migration |
Yes
|
Yes
|
Yes
|
| Online Spare Support |
Yes
|
Yes
|
Yes
|
| Capacity Extension |
Yes
|
Yes
|
Yes
|
| SAN Access Module |
No
|
No
|
Yes
|
| PCI Bus |
64-bit, 133-MHz PCI-X
|
64-bit, 133-MHz PCI-X
|
64-bit, 66-MHz
|
|
* Based on use of MSA30 Enclosure family (14 drives enclosure) |
| ** RAID ADG is a standard feature of SA-6404, SA-6402 and SA-5304, and available as an option on the SA-5302 RAID ADG requires a minimum of 64-MB battery-backed cache. |
|
|
Technical Specifications
| Dimensions (H x W x D) |
12.3 x 4.2 x .7 in (31.2 x 10.7 x 1.8 cm) | ||
| Weight | Smart Array 6402/128 | 3.12 lb (1.42 kg) | |
| Smart Array 6404/256 | 4.22 lb (1.91 kg) | ||
| Electrical Interface | LVD (Low Voltage Differential) | ||
| Protocol Support | Ultra320 SCSI (320 MB/s per channel) | ||
| SCSI Ports | 2 channel model: 2 external/2 internal shared | ||
| 4 channel model: 4 external/2 internal shared | |||
| Drives Supported | 2 channel model: up to 28 drives | ||
| 4 channel model: up to 56 drives | |||
| Maximum Capacity | 2 channel model: 8.40TB (28 drives x 300GB) | ||
| 4 channel model: 16.80TB (56 drives x 300GB) | |||
| PCI | PCI-X and 3.3 volt PCI compatibility
only NOTE: The SA-6400 is not supported in 5 volt PCI slots. |
||
| PCI Bus Speed | 64-bit/133-MHz PCI-X (1 GB/s maximum bandwidth) | ||
| Logical Drives | Up to 32 logical drives | ||
| Up to 2 TB per Logical Drive | |||
| RAID Support | RAID ADG (Advanced Data Guarding) | ||
| RAID 5 (Distributed Data Guarding) | |||
| RAID 1+0 (Striping & Mirroring) | |||
| RAID 0 (Striping) | |||
| Cache Memory |
128-, 256-, 512-MB Read/Write | ||
| ECC protection, battery-backed, and removable | |||
| Cache Batteries | Up to 4 days of redundant battery life, removable for easy replacement (3days with 256-MB Module, 1 day with 512-MB Module) | ||
| Upgradeable Firmware | 2-MB flashable ROM | ||
| Disk Drive and Enclosure Protocol
Support |
Ultra320, Wide Ultra 3, Wide Ultra 2 | ||
| Memory Addressing | 64-bit, supporting servers memory greater than 4 GB | ||
|
|
|||
|
Environment-friendly Products and Approach |
End-of-life Management and Recycling | Hewlett-Packard offers end-of-life HP product
return, trade-in, and recycling programs in many geographic areas. For trade-in
information, please go to http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be
recycled, recovered or disposed of in a responsible manner.
The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|
||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Unix and UnixWare are registered trademarks of The Open Group. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |