|
|
Overview
|
HP StorageWorks Modular Smart Array 1000 Specific for Tru64 UNIX or OpenVMS Only |
| Introduction |
| The HP StorageWorks Modular Smart Array 1000
is a 2 Gb Fibre Channel storage system designed for the entry-level to mid-range
Storage Area Network (SAN). Designed to reduce the complexity, expense and
risk of SAN deployment, the MSA1000 is a scaleable, high performance storage
system built with investment protection in mind. The modular design of the
MSA1000 allows the user to easily add storage capacity on an as needed basis.
The MSA1000 combines the array controller shelf and the drive shelf, which holds up to fourteen 1" universal disk drives in a single 4U rackmount cabinet. More storage can be easily deployed with the addition of up to two drive enclosures for a maximum storage capacity of 12 TB when using the new 300GB drives. The MSA1000 provides the latest 2 Gb Fibre Channel technology to the hosts. Besides the single port 2 Gb Fibre Channel I/O module that comes standard, there is an 8-port switch that mounts internally, featuring a low cost per port option that saves rack space. The MSA1000 provides Ultra3 SCSI connections to the hard drives and uses the HP Universal 1" Ultra2, Ultra3, and/or Ultra320 drives. By utilizing SCSI drives, the MSA1000 lowers the total cost of ownership and extends the customer's hardware investments into the future. With the introduction of the newest controller firmware version 4.32 or later it is no longer necessary to replace the standard firmware with an alternative version. For those users needing to upgrade an older MSA1000 with the newer firmware, it can be downloaded at no charge at http://www.hp.com/go/msa1000 |
|
|
| Key Features |
| The HP StorageWorks MSA1000 offers the following key features: |
|
|
| What's new |
|
|
| Supported Alpha servers |
|
|
|
|
| Cluster size supported |
Tru64 UNIX TruCluster: 4 nodes
OpenVMS: 8 nodes |
|
|
|
| Number of clusters |
1 |
|
|
|
| Single Cluster and Simultaneous
Single Server Support |
Yes |
|
|
|
| Boot from SAN |
Yes |
|
|
|
| All configurations require a switch
(FC-AL hubs are NOT supported) |
Yes |
|
|
Product Highlights
| High Levels of Performance, Scalability, and Functionality |
|
|
|
|
| Low Total Cost of Ownership |
The modular and scalable design of the MSA1000 provides an extremely flexibly platform. You can buy what you need today and purchase additional capacity and performance as your data storage needs grow, instead of making a large up-front investment. Additional drives, controllers, cache, fabric switches and storage enclosures can easily be added, as your storage needs change.
|
|
| Configuration |
|
|
|
|
Models
| HP StorageWorks Modular Smart Array 1000 For Alpha Server Systems with Tru64 UNIX or OpenVMS |
MSA1000, with 256MB cache |
201723-B22/ |
|
MSA1000 Controller, with 256MB cache |
218231-B22/ |
|
|
256 MB Cache upgrade module for Controller |
254786-B21/ |
|
|
MSA Fibre Channel I/O Module |
218960-B21/ |
|
|
MSA SAN Switch 2/8 (integrated) |
288247-B21/ |
|
| FCA2384 2 Gb PCI-X Host Adapter (OpenVMS/Tru64 UNIX) |
302784-B21
DS-KGPSA-EA |
|
| FCA2684 - HP StorageWorks 2 Gb, Single Channel, 133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for Tru64 UNIX and future support for OpenVMS |
DS-A5132-AA
|
|
| FCA2684DC - HP StorageWorks 2 Gb, Dual Channel, 133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for Tru64 UNIX and future support of OpenVMS |
DS-A5134-AA
|
|
| 1Gb FC Host Bus Adapter (Tru64 UNIX , OpenVMS) |
168794-B21
DS-KGPSA-CA |
|
| 2 Gb SFP SW Transceiver Kit |
221470-B21/
3R-A2973-AA |
|
| Modular Smart Array 30 (MSA30) drive enclosure, single bus | 302969-B21 | |
| Modular Smart Array 30 (MSA30) drive enclosure, dual bus | 302970-B21 |
![]() |
|
|
MSA1000 Components
| With the following components, your storage capacity and performance can be scaled to new levels: | |
| Modular Smart Array 1000 | The 4U cabinet houses up to fourteen
1" Universal hot pluggable Ultra2, Ultra3, and/or Ultra320 drives.
Each MSA1000 includes the following standard components: (1) MSA1000 Controller,
(1) MSA Fibre Channel I/O Module with a single SFP, dual hot pluggable fans/power
supplies and power cables, (2) 3' VHDCI to VHDCI SCSI cables to connect
expansion enclosures, documentation and a CD Kit containing a support software
CD. The modular design of the MSA1000 makes it possible to add redundant controllers, redundant single port Fibre Channel I/O Modules, or MSA SAN Switch 2/8 and storage expansion enclosures. When connected to an Alphaserver there must be a switch used as an interconnect. This can be one of the supported external switches or the optional embedded MSA SAN Switch 2/8. The MSA 3-port Hub is not supported. |
|
|
|
| MSA1000 Controller |
The MSA1000 Controller is an integrated RAID controller with an integrated LCD/LED status display and 256 MB read/write battery-backed cache (expandable to 512 MB per controller). One MSA1000 Controller is included with the MSA1000; a redundant MSA1000Controller is an option. |
|
| Key Features |
|
|
| MSA1000 Controller Management Features |
|
|
| Fault Tolerance |
Several fault tolerant configurations, which keep data available and servers running while drives are being replaced, are supported including:
|
|
| Fault Recovery |
|
|
|
|
||
| MSA Fibre Channel I/O Module | Provides a single 2 Gb Fibre Channel connection per controller into the MSA1000. The MSA Fibre Channel I/O Module includes one 2 Gb, Short Wave Small-Form-Factor-Pluggable Transceiver (SFP). A second MSA Fibre Channel I/O Module can be installed for redundancy when a redundant controller is used. A FC switch must always be used as an interconnect between the host HBAs and an MSA1000. Direct connect is not supported. |
|
|
|
| MSA SAN switch 2/8 |
The HP StorageWorks MSA SAN switch 2/8 is a new optional switch embedded on a blade, for mounting internal to an MSA1000. The MSA SAN Switch 2/8 offers low price per port and full scalability, doing so while taking zero rack space, even in a redundant configuration. It ships with four SFPs installed. Because of its' low cost per port it is the most cost effective method of enabling the larger SAN. It is interoperable with the HP line of SAN interconnect family of FC switches.
|
|
|
|
||
| 2 Gb Small-Form-Factor-Pluggable (SFP) SW Transceiver Kit | 2 Gb Small-Form-Factor-Pluggable (SFP) SW Transceivers are industry standard connection devices, which hot plug into 2 Gb infrastructure components such as 2 Gb Fabric Switches. HP StorageWorks 2 Gb SFP SW Transceivers support distances up to 300 meters at 2 Gb and 500 meters at 1 Gb using multi-mode fiber optic cable. |
|
|
|
| Multi-Mode Fibre Channel Cables | Multi-Mode Fibre Channel cables provide a thin, flexible cabling solution that is immune to electromagnetic interference. HP offers cables to connect the MSA1000 to both 2 Gb and 1 Gb Fibre Channel infrastructures. LC to LC cables are used when connecting the MSA1000 to other 2 Gb Fibre Channel components because both connections will utilize small-form-factor-transceivers. LC to SC cables are used when connecting the MSA1000 to 1 Gb Fibre Channel components. 1 Gb components use the larger GBIC style transceivers. |
|
| Software Components | |
| Command Line Interface (CLI) | The command line interface (CLI) is used to configure and manage the MSA1000. Additionally, the CLI can be used to display system information and status. See the HP StorageWorks Modular Smart Array 1000 User Guide for more information on the CLI commands. |
|
|
|
| OS Support | Tru64 UNIX Support |
|
| OpenVMS Support |
|
|
|
|
Service and Support, HP Care Pack and Warranty Information
| Storage Service Packages |
The Storage Services Packaging takes the existing storage
product along with the existing services and creates a package of the
storage hardware and appropriate services. The increased level of support
provides for a higher level of storage system availability for the customer.
The package includes 24x7 support with a 4-hour response for 3 years as
well as installation and startup service.
|
|
|
|
| Warranty |
Three-year Limited Warranty for MSA1000s, Fibre Channel
Cables and SFP Transceivers; 3 years parts exchange; 1 year labor; 1 year
on-site; next business day response. Options for the MSA1000 carry their
own warranty. Refer to HP's Limited Warranty Statement for further details.
|
|
|
|
| Software Product Services |
|
|
|
|
| Hardware Product Services |
|
|
|
|
| Installation and Startup Services |
The Installation and Startup Service package provides installation and configuration of HP StorageWorks products. Major categories of work could include:
|
|
|
|
| Warranty Upgrade Options |
|
|
|
|
| HP Care Pack Information | Fixed Price Care Pack Part
Numbers (Supported through all ordering systems) |
Part Number
|
| 3 Yr next Day/Onsite |
U6355A
|
|
| 3 Yr next Day/Onsite, Electronic |
U6355E
|
|
| 3 Yr Same Day/Onsite |
U6356A
|
|
| 3 Yr Same Day/Onsite, Electronic |
U6356E
|
|
| 3 Yr 7x24/Onsite |
U6357A
|
|
| 3 Yr 7x24/Onsite, Electronic |
U6357E
|
|
| 4 Yr Same Day/Onsite |
U9398A
|
|
| 4 Yr Same Day/Onsite, Electronic |
U9398E
|
|
| 4 Yr 7x24/Onsite |
U9399A
|
|
| 4 Yr 7x24/Onsite, Electronic |
U9399E
|
|
| 5 Yr Same Day/Onsite |
U9400A
|
|
| 5 Yr Same Day/Onsite, Electronic |
U9400E
|
|
| 5 Yr 7x24/Onsite |
U9401A
|
|
| 5 Yr 7x24/Onsite, Electronic |
U9401E
|
|
| 6 Hr. Call To Repair/Onsite |
U9934A
|
|
| 6 Hr. Call To Repair/Onsite, Electronic |
U9934E
|
|
| Hardware Installation |
U4368A
|
|
| Hardware Installation, Electronic |
U4368E
|
|
NOTE: For additional HP Care Pack (hardware
& software) information on European and other countries, as well as
orderable part numbers, please refer to the URL listed below: |
||
|
|
Configuration Information
|
Step 1 - Order Required Items
|
||
| HP StorageWorks Modular Smart Array 1000 |
201723-B22
|
|
| Includes: | ||
| (1) MSA1000 Controller with 256 MB cache | ||
| (1) MSA Fibre Channel I/O Module with 2 Gb SFP SW Transceiver | ||
| Redundant Hot Pluggable Power Supply/blower assemblies | ||
| Universal Rackmounting Kit | ||
| MSA1000 Support CD & Documentation for Tru64 UNIX & OpenVMS | ||
| (2) Power cables | ||
| (1) custom serial cable | ||
| NOTE: Fibre Channel cables are ordered separately. | ||
![]() |
|
|
Step 2 - Select Optional Non-Redundant MSA1000 System
Options
|
||
| MSA SAN Switch 2/8 (integrated) (Includes four 2Gb SFPs) |
288247-B21
|
|
| NOTE: The MSA SAN Switch 2/8 has seven external ports, four of which have transceivers installed. | ||
![]() |
|
|
Step 3 - Choose Redundant MSA1000 System Options
|
||
| MSA1000 Controller |
218231-B22
|
|
| NOTE: Redundant configurations require two Host Adapters per server, an additional controller for each server. Mixing of the MSA Fibre Channel I/O Modular and the MSA SAN Switch 2/8 is not supported. When configuring the MSA1000 for redundant controllers use either two MSA Fibre Channel I/O Modules or two MSA SAN Switch 2/8s. There must always be a switch between the Alpha server(s) and the MSA1000. Direct connect is not supported. | ||
![]() |
||
|
|
||
| MSA Fibre Channel I/O Module |
218960-B21
|
|
| MSA SAN Switch 2/8 (integrated) (Includes four 2Gb SFP transceivers) |
288247-B21
|
|
![]() |
|
|
Step 4 - Choose Supported Options For 2 Gb or 1 Gb Infrastructure
|
||
| 2 Gb Fibre Channel Transceiver (SFP) | 2 Gb SFP SW Transceiver Kit |
221470-B21
|
|
| 2 Gb Fibre Channel Fabric "B-series" family of switches | HP
StorageWorks MSA SAN Switch 2/8 (embedded option for MSA1000 only) NOTE: Includes four 2Gb SFP transceivers. |
288247-B21
|
| HP StorageWorks SAN Switch 2/8V |
AA979A
|
|
| HP StorageWorks SAN Switch 2/8V Power Pack |
AA980A
|
|
| HP StorageWorks SAN Switch 2/16V |
AA978A
|
|
| HP StorageWorks SAN Switch 2/16N |
AA990A
|
|
| HP StorageWorks SAN Switch 2/16N Power Pack |
AA977A
|
|
| HP StorageWorks SAN Switch 2/16 |
322118-B21
|
|
| HP StorageWorks SAN Switch 2/16 Power Pack |
322119-B21
|
|
| HP StorageWorks SAN Switch 2/32 |
240603-B21
|
|
| HP StorageWorks SAN Switch 2/32 Power Pack |
333764-B21
|
|
| HP StorageWorks core 2/64 |
332177-B22
|
|
| HP StorageWorks core 2/64 Power Pack |
332178-B22
|
|
| HP StorageWorks SAN Director 2/128 |
AA981A
|
|
| HP StorageWorks SAN Director 2/128 Power Pack |
AA982A
|
|
| 2 Gb Fibre Channel Fabric "C-Series" family of switches | Cisco MDS 9506 Multilayer Director w/0SFPs |
A7471A
|
| Cisco MDS 9509 Multilayer Director w/0 SFPs |
A7462A
|
|
| Cisco MDS 9216 Multilayer Fabric Switch |
A7473A
|
|
| Cisco MDS 9120 Fabric Switch w/0 SFPs |
A7426A
|
|
| Cisco MDS 9140 Fabric Switch w/0 SFPs |
A7427A
|
|
| NOTE: For "C-Series" information refer to: http://hp.com/go/SAN |
|
| 2 Gb Fibre Channel Fabric "M-series" family of switches | HP StorageWorks Edge Switch 2/32 NOTE: 16 active ports. Ships with 16 SFPs |
286810-B21
|
| 8-FlexPort upgrade for Edge 2/32 |
302660-B21
|
|
| HP StorageWorks Edge Switch 2/24 NOTE: 8 ports active. Ships with 8 SFPs |
316095-B21
|
|
| 8-FlexPort upgrade for Edge 2/24, includes transceivers |
316096-B21
|
|
| HP StorageWorks Edge Switch 2/12 NOTE: 4 ports active. Ships with 4 SFPs |
348406-B21
|
|
| 4-FlexPort upgrade for edge 2/12, includes transceivers |
348407-B21
|
|
| 2 Gb Fibre Channel HBAs | FCA2354 2 Gb PCI Host Adapter (Open VMS/Tru64 UNIX) |
261329-B21
|
| FCA2384 2 Gb PCI-X Host Adapter (OpenVMS/Tru64 UNIX) |
302784-B21
DS-KGPSA-EA |
|
| FCA2684 - HP StorageWorks 2 Gb, Single Channel, 133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for Tru64 UNIX and future support for OpenVMS |
DS-A5132-AA
|
|
| FCA2684DC - HP StorageWorks 2 Gb, Dual Channel, 133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for Tru64 UNIX and future support of OpenVMS |
DS-A5134-AA
|
|
| 1Gb FC Host Bus Adapter (Tru64 UNIX , OpenVMS) |
168794-B21
DS-KGPSA-CA |
|
| Fibre Channel Cables for 2 Gb Infrastructure | Use 2 Gb Fibre Channel cables
when connecting the MSA Fibre Channel I/O Module or the MSA Fabric Switch
6 to FCA2101 HBA(s) |
|
| 2 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B21
|
|
| 5 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B22
|
|
| 15 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B23
|
|
| 30 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B26
|
|
| 50 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B27
|
|
|
Step 5 - Choose Hard Drives & HP StorageWorks Enclosures
|
||
| Hard Drives | 72.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1") |
286714-B22
|
| 146.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1") |
286716-B22
|
|
| 300 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1") |
350964-B22
|
|
| 36.4 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1") |
286776-B22
|
|
| 72.8 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1") |
286778-B22
|
|
| 146.8 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1") |
347708-B22
|
|
| *NOTE: All Ultra320 Universal Hard Drives are backward compatible to U2 or U3 speeds. |
|
|
| HP StorageWorks Enclosures | The MSA1000 cabinet holds fourteen 1" Universal Drives. Add one HP StorageWorks Enclosure to increase capacity up to 28 drives. Add two HP StorageWorks Enclosures to increase capacity up to the maximum of 42 drives. | |
| Modular Smart Array 30 (MSA30) drive enclosure, single bus | 302969-B21 | |
| Modular Smart Array 30 (MSA30) drive enclosure, dual bus | 302970-B21 |
|
|
Step 6 - Choose Rack Options
|
||
| 9142 Rack |
120663-B21,
-B22, -B23 |
|
| 9136 Rack |
120664-B21,
-B22, -B23 |
|
| 9122 Rack |
120665-B21,
-B22, -B23 |
|
| 9842 Rack |
222192-B21
|
|
| 10647 (47U) rack |
245160-B21,
-B23 |
|
| 10642 (42U) rack |
245161-B21,
-B22, -B23 |
|
| 10636 (36U) rack |
245162-B21,
-B22, -B23 |
|
| 10622 (22U) rack |
245163-B21,
-B22, -B23 |
|
| H9A10 Cab |
H9A10-XX
|
|
| H9A15 Cab |
H9A15-XX
|
|
|
Configuration Examples
|
||
|
Two Node Redundant Cluster Solution Example
|
||
| Quantity | Description |
Part Number
|
|
1
|
HP StorageWorks Modular Smart Array 1000 |
201723-B22
|
|
1
|
additional MSA1000 Controller |
218231-B22
|
|
2
|
MSA SAN switch 2/8 (embedded) |
288247-B21
|
|
4
|
Host Adapter (example) |
261329-B21
|
|
4
|
2 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B21
|
|
14
|
36.4 GB Pluggable Ultra320 Universal Hard Drive, 15K |
286776-B21
|
|
4 Host, 6TB, Redundant SAN Solution Example |
|
| Quantity | Description |
Part Number
|
|
1
|
HP StorageWorks Modular Smart Array 1000 |
201723-B22
|
|
1
|
additional MSA1000 Controller |
218231-B22
|
|
2
|
256 MB Cache Modules for Controller (one additional for each controller) |
254786-B21
|
|
2
|
SAN Switch 2/16-EL |
283056-B21
|
|
8
|
Host Adapter (example) |
261329-B21
|
|
8
|
2 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B21
|
|
2
|
HP StorageWorks Enclosure Model 4314R |
190209-001
|
|
42
|
146.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1") |
286716-B22
|
|
|
Technical Specifications
| Modular Smart Array 1000 | LED Indicators on Front (3) | Power | |
| Fault detected in one or more sub-systems | |||
| Fault in Enclosure Management | |||
| LED Indicators for Drive Modules (3) | Drive Access (center) | ||
| Online (left) | |||
| Drive Failure (right) | |||
| LED Indicators on Rear Panel (4) | Power Supply/Blower Assembly Fault (1) | ||
| EMU (3) Power, A bus, B bus | |||
| Interface | Ultra3 SCSI to Hard Drives | ||
| 2 Gb Fibre Channel to Hosts | |||
| Maximum Number of Drives | Fourteen, 1-inch HP Ultra2, Ultra3 or Ultra 320 Universal Hard Drives (MSA1000 Cabinet); expandable to 42 using two additional HP StorageWorks 4200/4300 Enclosures | ||
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) | |
| Shipping | -22° to 122° F (-30° to 50° C) | ||
| NOTE: Derated 1°C per 1,000 feet of elevation to 10,000 ft. | |||
| Relative Humidity | Operating | 10% to 90% | |
| Non-operating | Up to 95% | ||
| Input Power Requirements | Rated Input Voltage | 100 to 240 VAC | |
| Rated Input Frequency | 50 to 60 Hz | ||
| Rated Input Current | 6 A Max | ||
| Input Power (max) | 549 W* | ||
| Heat Dissipation (max) | 1876 Btu/hr* | ||
| NOTE: Input Power and Heat Dissipation specifications are maximum values and apply to worst-case conditions at full rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment configuration. | |||
| MSA1000 Cabinet | 4U Rack Form Factor | ||
| Dimensions (H x W x D) | 6.9 x 19 x 20.5 in (17.5 x 48.3 x 52.1 cm) | ||
| Weight | Net 55 to 85 lb (24.95 to 38.56 kg) | ||
| Shipping Packaging | Dimensions (L x W x D) | 28.5 x 14.81 x 33.13 in (72.4 x 37.6 x 84.1 cm) | |
| Weight (Gross) | 75 to 105 lb (34.02 to 47.63 kg) | ||
|
|
|||
| Modular Smart Array 1000 Controller | User Interface | Controller Display
with Status Indicators (2) and Push Buttons (4) Status Indicators on front of Controller (16) |
|
| Electrical Interface | LVD (Low Voltage Differential) | ||
| Protocol Support | Wide Ultra3 SCSI (160 MB/s per channel) | ||
| SCSI Ports | 4-channel: 2 external/2 Internal | ||
| Drives Supported | Up to 42 drives | ||
| Maximum Capacity | 6.0 TB (42 drives x 146 GB) | ||
| Logical Drives | Up to 32 logical drives | ||
| RAID Support | RAID ADG (Advanced Data Guarding) | ||
| RAID 5 (Distributed Data Guarding) | |||
| RAID 1+0 (Striping & Mirroring) | |||
| RAID 0 (Striping) | |||
| Cache Memory | Up to 512 MB Read/Write (256 MB modules). If redundant controllers are used they must have equally configured cache | ||
| ECC protection, battery-backed, and removable | |||
| Standard as of November 19, 2002: 256 MB cache memory (single module) | |||
| Cache Batteries | Up to three days of redundant battery life, removable for easy replacement | ||
| Upgradeable Firmware | 2 MB flashable ROM | ||
| Disk Drive and Enclosure Protocol Support | HP Ultra 320, Ultra3, and Ultra2 SCSI 1-inch Universal drives | ||
| Packaging | Dimensions (L x W x D) | 17 x 12.5 x 7.75 in (43.2 x 31.75 x 19.7 cm) | |
| Weight (Gross) | 6 lb (2.72 kg) | ||
|
|
|||
| Modular Smart Array Fibre Channel I/O Module | Connector Type | LC | |
| Number of Fibre Channel Ports | One 2 Gb Fibre Channel Port using removable Small-Form-Factor-Pluggable Transceiver (SFP) | ||
| Bandwidth | 200 MB/s | ||
| Operation Modes | Fibre Channel Class 2 and 3 connectionless service | ||
| Protocols Supported | Fibre Channel | ||
| Packaging | Dimensions (L x W x D) | 17 x 12.5 x 7.75 in (43.2 x 31.75 x 19.7 cm) | |
| Weight (Gross) | 6 lb (2.72 kg) | ||
|
|
|||
| FCA2354 Host Adapter | Connector Type | LC | |
| Protocol | SCSI, IP | ||
| Data Transfer Method | 64-bit/66 MHz PCI | ||
| Maximum Transfer Rate | 200 MB/s | ||
| Packaging | Dimensions (L x W x D) | 11 x 8.5 x 3 in (27.9 x 21.6 x 7.6 cm) | |
| Weight (Gross) | 1 lb (0.45 kg) | ||
|
|
|||
| Multi-Mode Fibre Channel Cables Kits | Cable Type | LC-LC (2 Gb to 2 Gb connections) and LC-SC (2 Gb to 1 Gb connections) 50 Micron multi-mode Fiber | |
| Available Cable Lengths | 6.5 ft, 16.4 ft, and 49.2 ft (2 m, 5 m, and 15 m) | ||
| Packaging | Dimensions (L x W x D) | 11.5 x 9 x 1.5 in (29.2 x 22.8 x 3.8 cm) | |
| Weight (Gross) | 0.75 to 1 lb (0.34 to 0.45 kg) | ||
|
|
|||
| © Copyright 2005 Hewlett-Packard Development Company,
L.P.
The information contained herein is subject to change without notice. Unix is a registered trademark of The Open Group. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |