contents
 Overview      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Overview

HP bc1000 blade PC

 
HP bc1000 blade PC
At a Glance
  • 1.0-GHz Transmeta Efficeon TM8000
  • 40-GB Ultra ATA/100 5400 rpm hard drive
  • 512-MB DDR SDRAM PC2700 (333-MHz) expandable to 1024 MB (2 SODIMM slots)
    (NOTE: 32 MB of system RAM is reserved for processor usage.)
  • Two Broadcom 5705F 10/100 Integrated Network Controllers. NIC 1 is compliant with PXE (Pre-boot execution Environment)
  • Connector for graphics diagnostics card
  • Blade PCs protected by HP Services, including a limited three-year parts warranty with optional service uplifts available
Configuration Steps
For a complete configuration of the HP bc1000 blade PC system, you need:
 
1. HP bc1000 blade PC (sold in a single-pack or 10-pack)
 
2. HP e-Class Blade PC Enclosure (each can hold up to 20 blade PCs). The enclosure comes bundled with 20 licenses for the ProLiant Essentials Rapid Deployment Pack.
 
3. C-GbE Interconnect Switch (with 4 10/100/1000T Gigabit Ethernet RJ45 uplinks for up to 40-to-1 network cable reduction).
contents
 Overview      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Standard Features

HP bc1000 blade PC
Processor One Transmeta Efficeon TM8600 1.0-GHz processor, integrated North Bridge with 400-MHz Hyper Transport South Bridge interface

Cache Memory1024K L2

ChipsetALi M1563M South Bridge
NOTE: For more information regarding Acer Labs Inc, please see the following URL:
http://www.ali.com.tw/.

MemoryStandard512-MB DDR SDRAM PC2700 (333-MHz) (1x512 MB SODIMM)
(NOTE: 32 MB of system RAM is reserved for processor usage.)
Maximum1024 MB (2 SODIMM slots total)

Network ControllerTwo 5705F 10/100 Integrated Network Controllers. NIC 1is compliant with PXE

Internal StorageOne 40-GB Ultra ATA/100 5400 rpm hard drive

Industry Standard ComplianceACPI 1.0b; ANSI C63.4 - 1992; C.I.S.P.R. Pub 22; CFR 47, Part 15; EN 55022; EN 55024;
EN 60950: 2000; ICES-003; IEC 61000-4, Section 2-6, 8, 11; IEC 730-1; IEC 801, Part 2;
IPC-A-610; PC2700; PCI 2.3; PXE 2.1; SPD 1.2B; UL 94; UL 796; USB 1.1

ManageabilityHP Systems Insight Manager
ROM Based Setup Utility (RBSU)
Automatic System Recovery (ASR)
System Software Manager (SSM)
DOS-based replicated setup utility (REPSET)
Unit ID LED

High AvailabilityRobust boot block recovery ROM
F5 auto roll over to new blade
Dual network communication paths

SecurityAdministrator's password

OS SupportMicrosoft® Windows® XP Professional with Service Pack 2

HP e-Class Blade PC Enclosure (sold separately)
Rack CapabilityMounts in HP 10000 and 9000 series, HP System-E, as well as third-party, and Telco racks. Rack mounting hardware for HP and third-party racks ships standard with each blade enclosure. Telco rack-mounting hardware is a separately available option kit.

Rack Airflow RequirementsThe increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted blade PCs. The HP 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with blade PCs using the latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
  • Front and rear doors: If your 42U rack includes closing front and rear doors, you must allow 5,350 square cm (830 square inches) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
  • Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 inches).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
NOTE: Please consult the Setup & Installation Guide for the blade PC for additional details.

Enclosure includes3U high rack-mountable chassis with 20 blade PC bays
Rack mounting hardware for HP, Compaq-branded and third-party racks
Rear bay for Interconnect Switch for network cable management
Two (2) Diagnostic Adapters (see features following) for connecting keyboard, video, mouse and other devices locally to individual blade PCs
ProLiant Essentials Foundation Pack licenses for 20 Blade PCs (see features following), includes the HP Systems Insight Manager and ProLiant Essentials Rapid Deployment Pack CD
Four hot-plug fans
Dual hot-plug power supplies (600 watts each), power cords
Blade PC blanks (to fill 19 of the 20 blade PC bays)
Null-modem cable for serial connection to the Integrated Administrator serial "Console" connector
HP Documentation CD

Diagnostic Adapter InterfacesNOTE: Two Diagnostic Adapters are included with every enclosure.
Blade PC LEDs (6)
PS/2 Mouse
PS/2 Keyboard
VGA monitor (functional only when graphics diagnostics card installed)
Serial RS-232 port
USB 1.1 ports (2)

ProLiant Essentials Foundation Pack SoftwareHP Systems Insight ManagerSystems Insight Manager helps maximize system uptime and performance and reduces the cost of maintaining the IT infrastructure by providing proactive notification of problems before those problems result in costly downtime and reduced productivity. Insight Manager is easy to set up and provides rapid access to inventory information.
http://www.hp.com/go/hpsim/.
ProLiant Essentials Rapid Deployment Pack An automated solution for deployment and provisioning, enabling companies to quickly and easily adapt to changing business demands.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials.
Interconnect Switch Management System and Utilities Full featured web-based interface, menu-driven console interface, SNMP-based scripting utility and example scripts, SNMP and RMON MIBs, and TFTP utilities for management of interconnect switch.

C-GbE Interconnect Switch Features (sold separately)
  • Provides up to a 40-to-1 reduction in network cables for each blade enclosure using a pair of non-blocking layer 2 switch modules
  • Four RJ-45 10/100/1000T Gigabit Ethernet uplinks
  • Forty 10/100T Ethernet ports dedicated to blade-to-interconnect switch network communications
  • Communicate with all 40 blade PC network controllers through any one uplink connector and the management connector
  • Includes Integrated Administrator module (see features following)
  • Spanning tree protocol for loop-free path redundancy
  • Browser, scriptable CLI, and console-based interfaces for local and remote interconnect switch management
  • Manage entire interconnect switch through the Integrated Administrator connectors or any uplink connector
  • Telnet, RMON and SNMP support; SNMP-based scripting utility with example scripts
  • IGMP (internet group management protocol) multicasting and quality of service (QoS) packet prioritization
  • TFTP support for rapid deployment of multiple interconnect switches and to provide backup and restore capabilities
  • Industry-standard design compatible with industry-standard network components from leading network manufacturers
  • Fully pre-configured for rapid deployment and immediate operation in HP e-Class Blade PC Enclosure

For more information on the C-GbE Interconnect Switch, please visit the Web site at:
http://h18000.www1.hp.com/products/servers/proliant-bl/e-class/interconnect-switch.html.


HP Integrated Administrator Features
  • Out-of-band local console and remote network access to the blade enclosure and all 20 blade PCs via (one) RJ-45 10/100BaseT Fast Ethernet and (one) RS-232 management connectors
  • Provides local and remote access to the C-GbE Interconnect Switch command console
  • Remotely power on/off/reboot blade PCs and enclosures
  • Remotely toggle on/off unit identification (UID) LEDs of blade PCs and enclosures
  • Monitors and controls the enclosure fans, temperature sensors, power supplies, interconnect switch and blade PC status
  • Connect to each blade PC's serial text console for enabling full control over blade PC's Power-On Self Test (POST) and boot process, including the ROM-Based Setup Utility (RBSU).
  • User administration for up to 25 users. Blade PC bay privileges can be set on a per-user basis
  • Virtual NMI button generates non-maskable interrupt for crash debug and analysis
  • More than 100 scriptable commands enable automated management
  • Selective enabling of all protocols, such as Telnet
  • Logging of operating system console, blade PC and enclosure hardware events, user actions and invalid login attempts
  • Administrator notification that a blade is warm
  • Enclosure controller blade shutdown (graceful Windows shutdown) if blade overheats
  • Emergency blade shutdown in the event of a critical temperature fault
  • Enclosure Link (2) connectors reserved for future use.
CAUTION: The enclosure link (RJ-45) connectors on the interconnect tray are not to be used. Connecting an external device to these enclosure link (RJ-45) connecters may damage your external device.
For more information on the Integrated Administrator, please visit the Web site at:
http://h18000.www1.hp.com/products/servers/proliant-bl/e-class/integrated-admin.html.

Service and SupportHP Services provides a wide range of service offerings, including a three-year, limited parts warranty on the HP bc1000 blade PC.
CAUTION: Do not ship the blade PCs and enclosure while inside the rack without first installing the e-Class Enclosure Shipping Bracket (part number PH555A). Failure to use the shipping bracket may cause damage to the blade PC and/or enclosure, thereby voiding the warranty.

The HP e-Class Blade PC Enclosure has a three-year, limited warranty on parts, labor and on-site support.

Warranties are fully supported by a network of resellers and service providers in over 160 countries. HP warranty assistance is available 7x24, toll free in the United States and Canada. Other additional support services may be covered under warranty or available for an additional fee.

A full range of HP Care Pack packaged hardware and software services:

  • Add labor or on-site service for the blade PC
  • Installation and start up
  • Extended coverage hours and enhanced response times
  • System management and performance services
  • Availability and recovery services

NOTE: For more information, customer/resellers can contact http://www.hp.com/services/carepack.
NOTE: Certain restrictions and exclusions apply. Consult the Customer Support Center at 1-800-567-1616 for details.

contents
 Overview      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Models

bc1000 blade PC
DS658A (1 pack)
Processor1.0-GHz Transmeta Efficeon TM8600
Cache Memory1024K L2
Memory512-MB DDR SDRAM PC2700 (333-MHz)
Network ControllerTwo Broadcom 5705F 10/100 Integrated NICs
Hard Drive40-GB Ultra ATA/100 5400 rpm
Form FactorPlugs vertically into HP e-Class Blade PC Enclosure

bc1000 blade PC
DS659A (10 pack)
Processor1.0-GHz Transmeta Efficeon TM8600
Cache Memory1024K L2
Memory512-MB DDR SDRAM PC2700 (333-MHz)
Network ControllerTwo Broadcom 5705F 10/100 Integrated NICs
Hard Drive40-GB Ultra ATA/100 5400 rpm
Form FactorPlugs vertically into HP e-Class Blade PC Enclosure
contents
 Overview      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Options

Enclosure and SwitchHP e-Class Blade PC Enclosure (includes 20 licenses for ProLiant Essentials Rapid Deployment Pack at 50% of the standard per-node license list price)
DW366A
Enclosure Shipping Bracket Kit
NOTE: When shipping an enclosure in a rack, shipping brackets must be installed to the rack.
 
C-GbE Interconnect Switch (includes Integrated Administrator module)
DW367A

Memory512-MB DDR SDRAM PC2700 (333-MHz) Option Kit (1 x 512 MB)
PA715A

MiscellaneousPS/2 Mouse
DD440B
PS/2 KeyboardDT527A
TFT5600 Rackmount Keyboard and Monitor221546-001
TFT721OR 17-inch Rackmount Monitor348373-B21
Integrated Keyboard and Drawer257054-001
External USB MultiBay CaddyDC373A#ABA
Third-party Rail Kit for HP Input Devices287139-B21
Telco Rail Kit for HP Input Devices287138-B21
MultiBay 24X CD-ROM217396-930
Graphics Diagnostics Card (5 pack)DV300C

UPS and PDU Power Cord MatrixPlease see the UPS and PDU cable matrix that lists cable descriptions, requirements, and specifications for UPS and PDU units:
ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf.

Uninterruptible Power Systems – RackHP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage204404-001
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage192186-001
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage192186-002
Rack-Mountable UPS R6000 (6000VA, 6000 Watt) High Voltage
NOTE: The UPS R6000 has a hardwired input.
347207-001
UPS R12000 XR N+ x (200-240V) (hardwired)
NOTE: The UPS R12000 XR has a hardwired input and output.
207552-B22

UPS OptionsSNMP Serial Port Card
NOTE: Supports tower and rack UPS XR models ranging from 1000 – 3000VA.
192189-B21
Six Port Card
NOTE: Supports tower and rack UPS XR models ranging from 1000 – 3000VA.
192185-B21
High to Low Voltage Transformer (250VA)
NOTE: Supports R6000 UPS series only. 2.5 amps @ 125 Volts max output across two NEMA 5-15.
388643-B21
Extended Runtime Module, R1500 XR
NOTE: 2U each, two ERM maximum.
218971-B21
Extended Runtime Module, R3000 XR
NOTE: 2U each, one ERM maximum.
192188-B21
Extended Runtime Module, R5500 XR
NOTE: 3U each, two ERM maximum.
326564-B21
Extended Runtime Module, R6000
NOTE: 3U each, two ERM maximum.
347224-B21
Extended Runtime Module, R12000 XR, 4U
NOTE: 4U each, two ERM maximum.
217800-B21
R12000 XR BackPlate Receptacle Kit, (2) L6-30R
NOTE: The R12000 XR BackPlate Kit has a hardwired input.
325361-001
R12000 XR BackPlate Receptacle Kit, (2) IEC-309R
NOTE: The R12000 XR BackPlate Kit has a hardwired input.
325361-B21
SNMP-EN Adapter
NOTE: Supports R6000 UPS series only.
347225-B21
Multi-Server UPS Card
NOTE: Supports R6000 UPS series only.
123508-B21
Scalable UPS Card
NOTE: Supports R6000 UPS series only.
123509-B21

Rack-Mountable PDUs – 1U/0U (Up to 12 outlets)
NOTE: 0U mounting brackets shipped with the unit (separate option kit for 1U mounting).

HP Power Distribution Unit-16A (200 to 240V)
NOTE: The 16A PDU also connects to the high volt models of the UPS R3000 XR (need cable PN 340653-001) and the UPS R6000 models. Cable PN 340653-001 required if connecting to UPS R3000 XR (192186-002-High Volt model only).

207590-B21

HP Power Distribution Unit-40A (200 to 240V)
207590-B23
NOTE: Please see the following Power Distribution Unit (Zero-U/1U PDU) QuickSpecs for additional options, including cables:
http://h18000.www1.hp.com/products/quickspecs/10838_na/10838_na.html
 

Modular PDUs 1U/0U
(Up to 32 outlets)
Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)
NOTE: This model has a detachable input power cord and is adaptable to country specific requirements. The 16A PDU also connects to the high volt models of the UPS R3000 XR and R6000 models. Cable P/N 340653-001 required if connecting to UPS R3000 XR (192186-002-High Volt model only).
252663-B24
Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)252663-D72
Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)252663-D71
Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)
NOTE: This mPDU (252663-B21), 40A model has a hardwired input.
252663-B21
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs for additional options including shorter jumper cables and country specific power cords:
http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html

PDU OptionsThird Party PDU Mounting Kit
NOTE: This kit allows you to mount the Modular PDUs in racks other than the 9000/10000 Series racks (any racks using the standard 19" rail). For more details please refer the Modular PDU QuickSpecs.
310777-B21

Enterprise ConfiguratorPlease see the CO for configuration assistance at: http://www.hp.com/products/configurator.

HP Rack 10000 Series (Graphite Metallic)S10614 (14U) Rack Cabinet – Shock Pallet292302-B22
HP Rack 10647 (47U) – Pallet245160-B21
HP Rack 10647 (47U) – Crated245160-B23
HP Rack 10642 (42U) – Pallet245161-B21
HP Rack 10642 (42U) – Shock Pallet245161-B22
HP Rack 10642 (42U) – Crated245161-B23
HP Rack 10636 (36U) – Pallet245162-B21
HP Rack 10636 (36U) – Shock Pallet245162-B22
HP Rack 10636 (36U) – Crated245162-B23
HP Rack 10622 (22U) – Pallet245163-B21
HP Rack 10622 (22U) – Shock Pallet245163-B22
HP Rack 10622 (22U) – Crated245163-B23
HP Rack 10842 (42U) – 800 mm wide – Pallet257415-B21
HP Rack 10842 (42U) – Crated257415-B22
NOTE: -B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels)
-B23 (crated) used for air shipments of empty racks
NOTE: Not all HP equipment is qualified to be shipped in the Rack 10000 series.
 
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html
For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/racks/index.html.
 

Rack Options for HP Rack 10000 SeriesRack Blanking Panels – Graphite (Multi)
NOTE: Contains one each of 1U, 2U, 4U and 8U.
253214-B26
Rack Blanking Panels – Graphite (1U)
NOTE: The Rack Blanking Panels Kit contains 10 each of (1U).
253214-B21
Rack Blanking Panels – Graphite (2U)
NOTE: The Rack Blanking Panels Kit contains 10 each of (2U).
253214-B22
Rack Blanking Panels – Graphite (3U)
NOTE: The Rack Blanking Panels Kit contains 10 each of (3U).
253214-B23
Rack Blanking Panels – Graphite (4U)
NOTE: The Rack Blanking Panels Kit contains 10 each of (4U).
253214-B24
Rack Blanking Panels – Graphite (5U)
NOTE: The Rack Blanking Panels Kit contains 10 each of (5U).
253214-B25
600mm Stabilizer Kit – Graphite246107-B21
Baying Kit for Rack 10000 series (Carbon)248929-B21
42U Side Panel – Graphite Metallic246099-B21
110V Fan Kit (Graphite)
NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 5-15P.
257413-B21
220V Fan Kit (Graphite)
NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 6-15P.
257414-B21
36U Side Panel – Graphite Metallic246102-B21
47U Side Panel – Graphite Metallic255486-B21
9000/10000 Series Offset Baying Kit (42U)
NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U height together. Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of the two racks.
248931-B21

Cable ManagementFC Cable Routing Spool – box of 12293357-B21
Rail-to-Rail FC Cable Routing293358-B21
Side Rail FC Routing – box of 6293359-B21
Compaq Networking Cable Management Kit292407-B21
Cable Management D-Rings Kit
168233-B21

Rack Options for Rack 10000 SeriesMonitor Utility Shelf303606-B21
Ballast Option Kit120672-B21
100kg Sliding Shelf234672-B21
Rack Rail Adapter Kit (25" depth)120675-B21
9000/10000 Grounding Kit260457-B21
100-kg Shelf Kit
NOTE: This 100Kg Shelf Kit (PN 234672-B21) supports the Rack 10000 and 9000 series only.
234672-B21

Rack Options for HP, Third Party and Telco racksTelco rack-mounting hardware kit for HP e-Class Blade PC Enclosure266076-B21
Enclosure Shipping Bracket Kit
NOTE: When shipping an enclosure in a rack shipping brackets must be installed to the rack.
293119-B21
NOTE: For more information on rack and rack options, please visit the following url: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html. 
contents
 Overview      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Memory

HP bc1000 blade PC
Standard Memory

512-MB 333-MHz DDR SDRAM (1x512 MB SODIMM) installed. (NOTE: 32 MB of system RAM is reserved for processor usage.)

Standard Memory Plus Optional Memory

Up to 1024 MB of DDR SDRAM is available with the installation of optional DDR SDRAM memory expansion kits (sold separately).

MemorySlot
 12
Standard512 MBEmpty512 MB
Maximum1024 MB512 MB512 MB
contents
 Overview      Standard Features      Models      Options      Memory      Technical Specifications line.gif (50 bytes)

Technical Specifications

HP bc1000 blade PCDimensionsHeight4.7 in (11.94 cm)
Width0.8 in (2.03 cm)
Depth15.5 in (39.37 cm)
WeightMaximum 2.2 lb (1.0 kg)
Temperature1Operating50° to 95° F (10° to 35° C)
Non-operating shipping-40° to 140° F (-40° to 60° C)
Non-operating storage-4° to 140° F (-20° to 60° C)
Relative humidity1 (noncondensing)Operating10% to 90%
Non-operating shipping10% to 90%
Non-operating storage10% to 95%
LEDs (Top to bottom)Unit identificationOff = off
Steady blue = blade identified
Blinking blue = being accessed remotely
HealthOff = off
Green = health good
Amber = degraded or power up prohibited by the Integrated Administrator
Blinking or steady red = critical
NIC 1Off = off
Green = linked to network
Blinking green = Activity on network
NIC 2Off = off
Green = linked to network
Blinking green = activity on network
Drive activityOff = No drive activity
Blinking green = drive activity
PowerOff = no AC power to blade or enclosure
Amber = Enclosure on and in good health
Green = blade power on
NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.

40-GB Ultra ATA/100 Hard DriveCapacity40 GB 
InterfaceUltra ATA 100 
Transfer rate synchronous
(maximum)
100 MB/s 
Seek time (typical reads, including settling)Single track1.5 ms
Average12 ms
Maximum22 ms
Rotational speed5400 rpm 

Broadcom 5705F 10/100 Integrated NICNetwork interface10Base-T/100Base-TX
CompatibilityIEEE 802.3/802.3u compliant
Data transfer method32-bit bus-master PCI
FeaturesNIC 1 WOL enabled and PXE compliant
Network transfer rate10Base-T (half-duplex)10 Mb/s
10Base-T (full-duplex)20 Mb/s
100Base-TX (half-duplex)100 Mb/s
100Base-TX (full-duplex)200 Mb/s
ConnectorMates into enclosure center wall assembly
Cable support10Base-TCategories 3, 5, or 6 UTP; up to 328 ft (100 m)
100Base-TXCategory 5 or 6 UTP; up to 328 ft (100 m)

EnclosureDimensionsHeight (3U)5.25 in (13.34 cm)
Width19 in (48.26 cm)
Depth27 in (68.58 cm)
Weight (with interconnect tray)No blade PCs59 lb (26.76 kg)
20 blade PCs103 lb (46.7 kg)
Rated input (autosensing)VoltageMinimum: 90 VAC
Maximum: 264 VAC
Nominal: 100 to 120 VAC or 200 to 240 VAC
Frequency47 to 63 Hz
Current11.7 A at 90 VAC
8.5 A at 120 VAC
4.3 A at 240 VAC
Power1000 W
BTUsPer hour3416
Temperature1Operating50° to 95° F (10° to 35° C)
Shipping, 72 hours-40° to 140° F (-40° to 60° C)
Relative humidity (noncondensing)Operating10% to 90%
Non-operating10% to 95%
ManagementEnclosure self recovery
Health logs
Redundant power supply utility
Automatic System Recovery (ASR)
High availabilityRedundant hot-plug power supplies
Redundant hot-plug fans
NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.

Enclosure Hot-Plug Power SupplyDimensionsHeight3.579 in (9.14 cm)
Depth10.24 in (28.45 cm)
Width4.47 in (11.43 cm)
Weight6.5 lb (2.95 kg) 
Rated inputVoltage (autosensing)100 to 127 VAC (200 to 240 VAC)
Frequency47 to 63 Hz
Current8.5 A at 120 VAC (4.3 A at 240 VAC)
Power1000 W
Maximum peak power 1167 W
Rated outputVoltage/current5.01 V - 0.5 A ~ 34 A
3.33 V - 0.5 A ~ 36 A
12.1 V - 0.5 A ~ 38 A
5 Vaux - 0.2 A ~ 8 A
Power RMS 600 W
Maximum peak power700 W for 2 minutes
Temperature1Operating50° to 55° F (10° to 35° C)
Non-operating, shipping-40° to 85° F (-40° to 60° C)
Relative humidity1 (noncondensing)Operating10% to 90%
Non-operating10% to 95%
Dieletric voltage withstandInput to output2000 VAC minimum
Input to ground1500 VAC minimum
NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.

C-GbE Interconnect SwitchGeneralTwo 24-port Managed Layer 2 Ethernet switches for network cable reduction; fully pre-configured for immediate operation
Performance4.0 Gbps Switching bandwidth
12 million pps aggregate throughput (64-byte packets)
Full-wire speed for all connections
Forwarding modeStore and forward
MAC addresses16,382; MAC address based filtering and MAC address packet priority configuring
Memory64 MB Main
12 MB Flash
32 MB Packet Buffer
PortsFour RJ-45 10/100/1000 T/TX/T Gigabit Ethernet uplink ports for customer use
Forty 10/100 T/TX fast Ethernet downlink ports dedicated to blade PC to interconnect switch network connections
Two 10/100 T/TX Fast Ethernet ports dedicated to inter-switch module communications
One RS-232 DB-9 port (console connector for Integrated Administrator)
One 10/100 T/TX Fast Ethernet port (Network management connector for Integrated Administrator)
Auto-negotiation and auto-sensing with full-duplex
ManagementWeb-based interface with graphical user interface
Console menu driven Interface via local RS-232 and Telnet
Scriptable command line interface (CLI)
SNMP v1 (RFC 1157) with scripting tool and example scripts
RMON v1 (RFC 1757) groups 1, 2, 3, and 9
Telnet (RFC 854)
MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface MIB (RFC 2233), 801.1Q MIB (RFC 2684), RMON1 MIB (RFC 1757) groups 1, 2, 3, and 9, Ethernet MIB (RFC1643) and HP-specific switch MIBs
XML human read/write configuration file
TFTP client (RFC 783) for backup and remote download of configuration and history log files
IGMP (Internet Group Management Protocol) multicasting
Uplink port speed and link activity LEDs
Simple network time protocol (SNTP)
Broadcast, multicast, and DA-unknown packet storm control
BootP and DHCP client support
Port mirroring
HP Interconnect Switch Management System and Utilities
High availabilityDual network communication paths using redundant, non-blocking layer 2 switch modules with redundant inter-module communication links
Two redundant uplink ports per each interconnect switch module
Spanning tree protocol for loop-free path redundancy
SecurityMultilevel user names and passwords with configurable time out period setting, IP address restriction
IEEE standards compliance IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Ethernet
IEEE 802.3ab 1000Base-T Ethernet
IEEE 802.1D Spanning Tree Protocol
IEEE 802.1p Quality of Service (QoS) Packet Prioritization
IEEE 802.3x Flow Control
Form factorRemovable interconnect tray that plugs into the rear of the server blade enclosure
Network transfer rate10Base-T (half-duplex)10 Mb/s
10Base-T (full-duplex)20 Mb/s
100Base-TX (half-duplex)100 Mb/s
100Base-TX (full-duplex)200 Mb/s
1000Base-T (full-duplex, uplink ports only)2000 Mb/s
Cable support10Base-TCategories 3, 5, or 6 UTP; up to 328 ft (100 m)
100Base-TXCategory 5 or 6 UTP; up to 328 ft (100 m)
1000Base-T (uplink ports only)Category 5 or 6 UTP; up to 328 ft (100 m)

© Copyright 2005 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.

Microsoft and Windows NT are US registered trademarks of Microsoft Corporation.

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.


   DA-11903 - U.S. - Version 6 - November 7, 2005