Overview
|
HP ProLiant DL145
| ||||||||||||||||||||||||
| What's New |
|
New 1U server supports 2 AMD Opteron Model 250(2.4GHz/1MB) Processors
and 800MHz HyperTransport Technology |
|
|
| At A Glance |
*NOTE: Customers who deploy SCSI model or option will forfeit the single PCI-X expansion slot by populating slot with U320 SCSI HBA. |
|
|
Standard Features
|
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. |
|
| Processor One of the following depending on Model: |
AMD Opteron Model 250 (2.4GHz/1MB) processor supporting HyperTransport Technology. |
| AMD Opteron Model 248 (2.2GHz/1MB) processor supporting HyperTransport Technology. | |
| AMD Opteron Model 244 (1.8GHz GHz/1MB) processor supporting HyperTransport Technology. | |
| AMD Opteron Model 242 series (1.6GHz/1MB) processor supporting HyperTransport Technology. | |
|
|
|
| Memory Protection |
Advanced ECC capabilities |
|
|
|
| Memory One of the following depending on Model: |
Type | PC2700 DDR SDRAM running at 333MHz |
| Standard | 1GB (2 x 512MB) (NOTE: Available with 1.6GHz models.) |
|
| 2GB (2 x 1GB) (NOTE: Available with 2.4, 2.2 and 1.8GHz models.) |
||
| Maximum | 16GB (8 x 2GB) | |
|
|
||
| Network Controller | Integrated Dual Broadcom 5704 10/100/1000 NICs (Wake on LAN and PXE capable) |
|
| |
| Expansion Slots | Slot # | Bus Speed |
Bus #* | Device #** |
Hot Plug (Y/N) |
Voltage/ Connector |
Notes |
|
1
|
64-bit/133MHz PCI
|
3
|
1
|
No
|
3.3 Volt
|
||
| NOTE: For more information regarding PCI-X, please see the following URL: http://www.hp.com/servers/pci-x. | |||||||
| NOTE: All slots can accept universal keyed PCI cards. | |||||||
|
|
|||||||
| Storage Controller | Integrated Dual Channel Ultra ATA-100 IDE standard or optional U320 SCSI HBA or U320 SCSI HBA standard depending on model |
| | |
| Storage | Diskette Drives | None |
| DVD-ROM | None | |
| Hard Drives | One 40GB ATA or one 36.4GB 15K SCSI drive standard depending on model | |
| Maximum Internal Storage |
Up to 320GB on ATA Models (2
x 160GB ATA) Up to 146GB on SCSI Model (2 X 72.8GB SCSI) |
|
| | ||
| Maximum Internal Storage | Type | ||
| ATA | Up to 320GB | (2 x 160GB) | |
| SCSI | Up to 146GB | (2 X 72.8GB) | |
|
|
|||
| Interfaces | Parallel | None |
| Serial | 1 | |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard | 1 | |
| USB | 2 (one front; one rear) NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
| Network RJ-45 (Ethernet) | 3 (2 GbE and 1 10MB out of band management NIC) | |
| | ||
| Graphics | Integrated ATI RAGE XL Video Controller with 8MB SDRAM Video Memory |
|
| |
| Form Factor | Rack Mount (1U) |
| | |
| Industry Standard Compliance | ACPI V2.0 Compliant |
| PCI 2.2 Compliant | |
| PXE Support | |
| WOL Support | |
| Microsoft® Logo certifications | |
| IPMI 1.5 Compliant | |
|
|
|
| Manageability | DL145 Lights-Out 100 Remote Management Card |
| BIOS Serial Console Redirect | |
| Command Line Interface Support | |
| Out of Band Power Server On/Off/Reset | |
|
|
|
| Security | Power-on password |
| Setup password | |
| | |
| Server Power Cords | One Highline IEC Power cord ships standard (for connection to a Power Distribution Unit) |
| | |
| Power Supply | 500 Watts, auto-switching, PFC (Power Factor Correcting) |
|
| |
| System Fans | 5 Non-hot plug, Non-redundant system fan shipped standard |
| | |
| OS Support | Microsoft Windows® 2000
Server Microsoft Windows 2000 Advanced Server Microsoft Windows 2003 Standard Edition Microsoft Windows 2003 Enterprise Edition Microsoft Windows 2003 Web Edition Red Hat Enterprise Linux 3 SuSE Linux Enterprise Edition 8 VMware Virtualization Software |
| NOTE: For an
up-to-date listing of the latest OS support matrix, please see: http://www.hp.com/go/supportos. NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant DL145, please see: http://h18023.www1.hp.com/support/files/server/us/index.html. NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html. |
|
|
|
|
| ProLiant Essentials Foundation Pack Software | HP Systems Insight Manager | HP's new HP Systems Insight Manager (HP SIM) helps maximize system uptime and performance and reduce system maintenance costs by providing proactive notification of problems before those problems result in unplanned downtime or reduced productivity. HP SIM are both easy to set up work with the Insight Management Agents, integrated Light-Out and Remote Insight Light-Outs Edition, and Version Control Agents to deliver robust fault, configuration, and asset management as well as remote administration. With HP SIM customers will also be able to take advantage of role-based security; the ability to manage ProLiant, Integrity, and HP 9000 systems; and plug-ins for storage, client, printer, and power management as well as server rapid deployment, performance management, and workload management. For more details on HP SIM visit http://www.hp.com/go/hpsim. |
| Optional ProLiant Essentials Value Packs | Optional software offerings that selectively extend the functionality of an Adaptive Infrastructure to address specific business problems and needs: | |
|
||
| NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value
Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
|
|
| Telco Rack Support | DL145 Telco Rack Kit: Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions. (http://www.racksolutions.com/hp). |
|
|
|
| Factory Express Portfolio for Servers and Storage | HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and/or
storage products. Customers can choose how their factory solutions are built,
tested, integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services on your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
|
|
| Service and Support |
HP Services provides a one-year, limited warranty fully supported by HP Services and a worldwide network of resellers and service providers. In addition, 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services. NOTE: Limited warranty includes 1 year parts, 0 years Labor, 0 years on-site support Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including:
HP Care Pack Services include HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3KVA. 22" and smaller external monitors will be covered at the same service level and coverage period as the server. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. |
|
NOTE: For more information on HP Care
Pack services, contact any of our worldwide sales offices or resellers
or visit our worldwide Web site on the internet at: |
|
|
Models
| ProLiant
DL145 2.4GHz Opteron 2GB 365520-XX1 (ATA Model with optional SCSI) | Processor | AMD Opteron Model 250 (2.4GHz/1MB) processor |
| Cache Memory | 1MB L2 cache | |
| Memory | 2GB (2 x 1GB) PC2700 DDR SDRAM running at 333MHz, with Advanced ECC capabilities | |
| Network Controller | Integrated Dual Broadcom 5704 10/100/1000 NICs (Wake on LAN and PXE capable) | |
| Storage Controller | Integrated Dual Channel Ultra ATA-100 IDE or optional U320 SCSI HBA | |
| Hard Drive | One 40GB non-hot plug ATA drive standard; support for two ATA (or two SCSI) non-hot plug hard drives | |
| Internal Storage | Up to 320GB on ATA Models (2 x 160GB ATA) | |
| Form Factor | Rack Mount (1U) | |
| | ||
| ProLiant
DL145 2.4GHz Opteron 2GB 368232-XX1 (*SCSI Model only) |
Processor | AMD Opteron Model 250 (2.4/1MB) processor |
| Cache Memory | 1MB L2 cache | |
| Memory | 2GB (2 x 1GB) PC2700 DDR SDRAM running at 333MHz, with Advanced ECC capabilities | |
| Network Controller | Integrated Dual Broadcom 5704 10/100/1000 NICs (Wake on LAN and PXE capable) | |
| Storage Controller | Integrated U320 dual-channel SCSI HBA | |
| Hard Drive | One 36GB 15K non-hot plug SCSI drive standard; support for two non-hot plug SCSI hard drives | |
| Internal Storage | Up to 146GB (2 x 72.8 GB) on SCSI models | |
| Form Factor | Rack Mount (1U) | |
| SCSI Model Notes | *Customers who deploy SCSI model will forfeit the single PCI-X expansion slot by populating slot with SCSI HBA | |
|
|
||
| ProLiant
DL145 2.2GHz Opteron 2GB 360520-B21 (ATA Model with optional SCSI) |
Processor | AMD Opteron Model 248 (2.2/1MB) processor |
| Cache Memory | 1MB L2 cache | |
| Memory | 2GB (2 x 1GB) PC2700 DDR SDRAM running at 333MHz, with Advanced ECC capabilities | |
| Network Controller | Integrated Dual Broadcom 5704 10/100/1000 NICs (Wake on LAN and PXE capable) | |
| Storage Controller | Integrated Dual Channel Ultra ATA-100 IDE or optional U320 SCSI HBA | |
| Hard Drive | One 40GB non-hot plug ATA drive standard; support for two ATA (or two SCSI) non-hot plug hard drives | |
| Internal Storage | Up to 320GB on ATA Models (2 x 160GB ATA) | |
| Form Factor | Rack Mount (1U) | |
| | ||
| ProLiant DL145
1.8GHz Opteron 2GB 360519-B21 (ATA Model with optional SCSI) |
Processor | AMD Opteron Model 244 (1.8/1MB) processor |
| Cache Memory | 1MB L2 cache | |
| Memory | 2GB (2 x 1GB) PC2700 DDR SDRAM running at 333MHz, with Advanced ECC capabilities | |
| Network Controller | Integrated Dual Broadcom 5704 10/100/1000 NICs (Wake on LAN and PXE capable) | |
| Storage Controller | Integrated Dual Channel Ultra ATA-100 IDE or optional U320 SCSI HBA | |
| Hard Drive | One 40GB non-hot plugATA drive standard; support for two ATA (or two SCSI) non-hot plug hard drives | |
| Internal Storage | Up to 320GB on ATA Models (2 x 160GB ATA) | |
| Form Factor | Rack Mount (1U) |
|
|
Configuration Information - Factory Integrated Models (North America only)
|
NOTE: For Configure to Order requirements
within EMEA region, please consult local Sales Contact. |
||
| Models | HP ProLiant DL145 Rack Chassis (North America) |
365172-405
|
| Factory Integrated Models ship with: | ||
| Integrated Dual Broadcom 5704 10/100/1000 NICs (Wake on LAN and PXE capable) | ||
| Integrated Dual Channel Ultra ATA-100 IDE | ||
| 500 Watts, auto-switching, PFC (Power Factor Correcting) | ||
| Rack Mount (1U) | ||
|
|
||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Base Processors | AMD O242 1.8GHz/1MB DL145 FIO BASE | 361035-L21 |
| AMD O248 2.2GHz/ 1MB DL145 FIO
BASE |
361036-L21
|
|
| AMD O250 2.4GHz/ 1MB DL145 FIO BASE |
366619-L21
|
|
|
|
||
| Base Memory | 1-GB PC2700 2x512KB FIO BASE |
361037-B21
|
| 2-GB PC2700 2x1GB FIO BASE |
361038-B21
|
|
| 4-GB PC2700 2x2GB |
361039-B21
|
|
|
|
||
| Base Hard Drives | 40-GB 7,200 rpm ATA, Non-Hot Plug
Hard Drive |
230534-B21
|
| 80-GB 7,200 rpm, ATA, Non-Hot
Plug Hard Drive |
278424-B21
|
|
| 160-GB 7,200 rpm, ATA, Non-Hot
Plug Hard Drive |
366486-B21
|
|
| 72-GB 10,000 rpm, U320,SCSI Universal Non-Hot Plug Hard Drive, 1" |
332751-B21
|
|
| 146.8-GB 10,000 rpm, U320 SCSI, Universal Non-Hot Plug Hard Drive, 1" |
356990-B21
|
|
| 36.4-GB 15,000 rpm, U320 SCSI,
Universal Non-Hot Plug Hard Drive |
357012-B21
|
|
|
|
||
| Step 3: Choose Additional Factory Integratable Options | ||
| Controllers | 2-ch U320 SCSI HBA PR ALL NOTE: Must select if choosing SCSI Drives in Step 2. |
268351-B21
|
| DL145 U320 INT CABLE ALL NOTE: Must select if choosing 268351-B21 |
370520-B21 | |
|
|
||
| Operating Systems | Microsoft Windows 2003 Server
Standard Edition, Pre-install |
339105-B21
|
| Microsoft Windows 2003 Server
Web Edition, Pre-install |
339233-B21
|
|
| Microsoft Windows 2003 Server Enterprise Edition, Pre-install |
339234-B21
|
|
|
|
||
| Step 4: Choose Additional Options for Factory Integration |
| NOTE: For additional options, please refer to the "Options" section below. |
|
|
Options
| NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. | ||
| ProLiant Essentials Value Pack Software |
ProLiant Essentials Intelligent Networking Pack | |
| ProLiant Essentials Intelligent Networking Pack Windows Edition, Single Server License |
372906-B21
|
|
| NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.html | ||
| ProLiant Essentials Vulnerability and Patch Management Pack | ||
| ProLiant Essentials Vulnerability and Patch Management Pack, 1-Server + 10 Desktop Bundle License |
389941-B21
|
|
| NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.html | ||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
||
|
|
||
| ProLiant DL145 Unique Options |
DL145 CTO Rack Shipping Bracket NOTE: The DL145 CTO Rack Shipping Bracket is required for customers who are purchasing DL145 systems as part of a factory integrated rack. Each kit contains 4 shipping brackets, one bracket per server. For example, a factory integrated rack with 32 nodes would require 8 DL145 CTO Rack Shipping Bracket kits. |
372851-B21
|
| DL145 U320 SCSI Cable NOTE: The DL145 U320 SCSI Cable is required for customers who wish to upgrade any DL145 ATA model with SCSI functionality. This cable comes standard in the DL145 SCSI BTO Model, part number 368232-001. |
370520-B21 | |
|
|
||
| Processor | AMD Opteron Model 242 (1.6GHz/1MB) Processor Option Kit |
361034-B21
|
| AMD Opteron Model 244 (1.8GHz/1MB) Processor Option Kit | 361035-B21 | |
| AMD Opteron Model 248 (2.2GHz/1MB) Processor Option Kit |
361036-B21
|
|
| AMD Opteron Model 250 (2.4GHz/1MB) Processor Option Kit |
366619-B21
|
|
|
|
||
|
Memory (DIMMs) |
1GB of Advanced ECC PC2700 DDR
SDRAM DIMM Memory Kit (2 x 512 MB) |
361037-B21 |
| 2GB of Advanced ECC PC2700 DDR
SDRAM DIMM Memory Kit (2 x 1GB) |
361038-B21 | |
| 4GB of Advanced ECC PC2700 DDR SDRAM DIMM Memory Kit (2 x 2GB) | 361039-B21 | |
|
|
||
| Optical Drives | DVD-ROM Option Kit |
361040-B21
|
|
| ||
| Storage Controllers | Ultra320 SCSI HBA (for internal
drives only) |
268351-B21
|
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
|
| U320 SCSI Cable (SCSI Cable is required for SCSI functionality) |
370520-B21
|
|
| FCA 2214 Host Bus Adapter (32-bit
Windows & Linux only) |
281541-B21
|
|
| FCA 2214DC Dual Channel Host Bus
Adapter (32-bit Windows & Linux only) |
321835-B21
|
|
|
|
||
| External Storage | HP StorageWorks Modular Smart Array 1000 | 201723-B22 |
| NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.html | ||
|
|
||
| Communications | HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter | 367132-B21 |
| HP NC310F PCI-X 1000SX Gigabit Server Adapter | 368169-B21 | |
| HP NC320T PCI Express 1000T Gigabit Server Adapter | 367047-B21 | |
| HP NC1020 PCI 1000T Gigabit Server Adapter | 353377-B21 | |
| HP NC6170 PCI-X Dual Port 1000SX Gigabit Server Adapter | 313879-B21 | |
| HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter | 313881-B21 | |
| HP NC7771 PCI-X 1000T Gigabit Server Adapter | 290563-B21 | |
| HP NC570C PCI-X Dual-port 4x Fabric Adapter | 376158-B21 | |
| HP NC571C PCI Express Dual-port 4x Fabric Adapter | 376160-B21 | |
| HP 24-Port 4x Fabric Copper Switch | 376227-B21 | |
| HP 4x Fabric 1m Copper Cable | 376232-B21 | |
| HP 4x Fabric 3m Copper Cable | 376232-B22 | |
| HP 4x Fabric 5m Copper Cable | 376232-B23 | |
| Myrinet-Fiber/PCI-X Interface (Dual channel Rev. D card) | 360040-B21 | |
| Myrinet XP-Fiber/PCI-X interface, M3F-PCIXD-2 | 257894-006 | |
|
|
||
| HP KVM Switch Options | HP 1x4 USB/PS2 KVM TableTop Switch (NA/JPN) | 371301-D71 |
| HP 1x4 USB/PS2 KVM TableTop Switch (AU/NZ) | 371301-011 | |
| HP 1x4 USB/PS2 KVM TableTop Switch (UK) | 371301-031 | |
| HP 1x4 USB/PS2 KVM TableTop Switch (EU) | 371301-A21 | |
| HP 1x4 USB/PS2 KVM Rack-mount Switch | 371302-B21 | |
| HP 6 foot, 2-pack, PS2 w/audio KVM Cable | 371730-B21 | |
| HP 6 foot, 2-pack, USB w/audio KVM Cable , | 371729-B21 | |
| Server Console Switch (KVM), 0 x 1 x 8 port | 336044-B21 | |
| Server Console Switch (KVM), 0 x 2 x 16 port | 336045-B21 | |
| IP Console Switch Box (KVM/IP), 1 x 1 x 16 | 262585-B21 | |
| IP Console Switch Box (KVM/IP), 3 x 1 x 16 | 262586-B21 | |
| CAT5 KVM Serial Interface Adapter | 373035-B21 | |
| PS/2 Interface Adapter, 8 pack |
262587-B21 | |
| PS/2 Interface Adapter, 1 pack |
262588-B21 | |
| CAT5 KVM USB Interface Adapter, 1 pack | 336047-B21 | |
| CAT5 KVM Expansion Module | 262589-B21 | |
|
|
||
| Hard Drives | 40-GB 7,200 rpm ATA, Non-Hot Plug Hard Drive |
230534-B21
|
| 80-GB 7,200 rpm, ATA, Non-Hot Plug Hard Drive |
278424-B21
|
|
| 160-GB 7,200 rpm, ATA, Non-Hot
Plug Hard Drive |
366486-B21 | |
| 72.8-GB 10,000 rpm, U320 SCSI Universal Non-Hot Plug Hard Drive, 1" | 332751-B21 | |
| 146.8-GB 10,000 rpm, U320, SCSI Universal Non-Hot Plug Hard Drive, 1" | 356990-B21 | |
| 36.4-GB 15,000 rpm, U320 SCSI Universal Non-Hot Plug Hard Drive, 1" | 357012-B21 | |
| NOTE: ATA drives include a one-year warranty | ||
|
|
||
| USB Options | HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) |
DC172B
|
| USB 1.44-MB External Diskette Drive |
DC141B
|
|
|
|
||
| Service and Support Offerings (HP Care Pack Services) |
|
|
|
Tested Product List
| NOTE: The Tested Product List (TPL) is a list of HP and standard 3rd party devices (hardware or software) that have been tested by either HP or independent test houses for basic compatibility with the HP ProLiant DL145 server. HP products are supported by HP, non-HP products are not supported by HP. For non-HP products, you must obtain support from their own manufacturer. Non-HP third party products have been tested only for compatibility with the specified HP server. This level of testing confirms proper device recognition by the HP server and basic compatibility with the identified HP server. HP disclaims all responsibility and liability for the manufacturing, distribution, marketing, licensing, installation, use, performance, maintenance, safety, regulatory certification, and support of these 3rd party products. |
|
|
| HPTC Interconnect | Manufacturer | Myricom |
| Product | Myrinet XP -Fiber/PCI-X interface, M3F-PCIXD-2 | |
| Data Transfer Method | 64-bit, 133/66MHz PCI-X/PCI Bus Master |
|
|
Memory
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| HP ProLiant DL145 Single Processor Models |
| Standard
Memory 1GB (2 x 512MB) or 2GB (2 x1GB) of PC2700 DDR SDRAM running at 333MHz, with Advanced ECC capabilities Memory installed (depending on model). Maximum Memory Up to 16GB of memory is available with the removal of the standard 512MB or 1GB of memory and the optional installation of 2GB PC2700 Registered ECC DDR SDRAM DIMM Memory kits. |
|
Memory Options |
| The server provides double data rate (DDR) synchronous dynamic RAM (SDRAM) that can improve memory clock speed to at least 333-MHz. It activates output on both the rising and falling edge of the system clock rather than on just the rising edge, potentially doubling output. The server features the following advanced memory technologies: |
|
|
Memory Guidelines |
|
| NOTE: Chart does not represent all possible memory configurations. |
| Memory | Slot | |||||||
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
| Standard
(1GB) |
512MB | 512MB | Empty | Empty | Empty | Empty | Empty | Empty |
| Maximum (16GB) | 2GB | 2GB | 2GB | 2GB | 2GB | 2GB | 2GB | 2GB |
|
Following are memory options available from HP: |
|
|
361037-B21 |
|
361038-B21 |
|
361039-B21 |
|
|
Storage
|
|
1, 2 | Two 1" Non-Hot Plug ATA-100 or U320 SCSI Hard Drive Bays |
| 3 | 24x IDE (ATAPI) DVD-ROM (optional) | |
| Drive Support | ||||
| | ||||
| Removable Media | ||||
| Quantity Supported |
Position Supported | Controller | ||
| IDE (ATAPI) DVD-ROM Drive | Up to 1 | 3 | Integrated IDE (ATAPI) (optional) | |
|
| ||||
| Hard Drives | |||
| ATA/100 IDE - Non-Hot Plug | |||
| Quantity Supported |
Position Supported |
Controller |
|
| 1-inch |
|
||
| 40.0 GB |
Up to 2 | 0, 1 | Integrated Dual Channel Ultra ATA-100 Adapter |
| 80.0 GB | Up to 2 | 0, 1 | Integrated Dual Channel Ultra ATA-100 Adapter |
| 160.0 GB | Up to 2 | 0, 1 | Integrated Dual Channel Ultra ATA-100 Adapter |
| SCSI - Non-Hot Plug | |||
| Quantity Supported |
Position Supported |
Controller |
|
| 1-inch | |||
|
36.4 GB 15K |
Up to 2 | 0, 1 | U320 SCSI Host Bus Adapter (standard on SCSI models and optional on ATA models) |
| 72 GB 10K | Up to 2 | 0, 1 | U320 SCSI Host Bus Adapter (standard on SCSI models and optional on ATA models) |
|
|
Power Specifications
| Spare Kit | 361620-001 |
| Operational Input Voltage Range
(Vrms) |
85Vac to 264Vac full range (auto-switching) |
| Frequency Range (Nominal) (Hz) |
50 Hz to 60 Hz |
| Power Output | 500W Nominal |
| Power Cords (Nema 5-15P to IEC320-C13) | |
| Standard Power Cord Part Number (US) | 163719-002 |
| Option Power Cord Part Number (US) | 227099-001 |
|
|
Technical Specifications
| System Unit | Dimensions (HxWxD) | 1.7 x 17 x 28 inches | |
| Weight (approximate; fully configured) | 26.5 lb (12.0 kg) | ||
| Input Requirements (per power supply) |
Range Input Voltage | 85 VAC to 264 VAC | |
| Normal Line Voltage | 115 or 230 VAC | ||
| Line Frequency | 50 to 60 Hz | ||
| Rated Input Current load | 2.5A @ 100V, 1.0A @ 240V | ||
| BTU Rating | 1006 BTU-Hr (max configuration) | ||
| Power Supply Output Power (per power supply) | Rated Steady-State Power | 500W | |
| Temperature Range | Operating | 50° to 93° F (10° to 35° C) | |
| Shipping | -40° to 140° F (-40° to 60° C) | ||
|
Relative Humidity |
Operating | 210% to 80% | |
| Non-operating | 5% to 95% | ||
| Acoustic Noise | Idle (Fixed Disk Drives
Spinning) |
||
|
7.3 | ||
| Operating (Random Seeks to Fixed Disks) |
|||
|
7.3 | ||
|
|
|||
| Non-Hot
Plug ATA/100 Hard Drives 230534-B21 |
40 GB 7.2K | Capacity | 40027 MB | |
| Height | 1.0 in (2.54 cm) | |||
| Width | 4.0 in (10.16 cm) | |||
| Interface | ATA 100 | |||
| Transfer Rate Synchronous (Maximum) |
100 MB/s | |||
| Seek Time (typical reads, including settling) | Single Track | 0.8 ms | ||
| Average | 8.5 ms | |||
| Full-Stroke | 17.8 ms | |||
| Rotational Speed | 7,200 rpm | |||
| Physical Configuration | Bytes/Sector | 512 | ||
| Logical Blocks | 78,177,792 | |||
| Operating Temperature | 41° to 131° F (5° to 55° C) | |||
|
|
||||
| Non-Hot Plug U320 SCSI
Hard Drive 357012-B21 |
36.4GB 15K | Capacity | 36419.2 MB | |
| Height | 1.0 in/2.54 cm | |||
| Width | 4.0 in/10.16 cm | |||
| Interface | Ultra320 SCSI | |||
| Seek Time (typical reads, including settling) | Single Track | 0.4 ms | ||
| Average | 3.8 ms | |||
| Full-Stroke | 8ms | |||
| Rotational Speed | 15,000 rpm | |||
| Physical Configuration | Bytes/Sector | 512 | ||
| Logical Blocks | 71,132,000 | |||
| Operating Temperature | 50° to 95° F (10° to 35° C) | |||
|
|
||||
| Integrated Dual Channel Ultra ATA-100 Adapter (ATA Models only) | Drives Supported | Up to 2 IDE devices |
| Channels | 2 (ATA Drives, CDROM) | |
| Storage Capacity | 320 (2X160) GB internal storage | |
| Data Transfer Method | 32-bit/33-MHz PCI bus-master | |
| Maximum ATA Channel Transfer Rate | 100 MB/s per channel | |
| Maximum Transfer Rate per PCI Bus (peak) | 266 MB/s per channel | |
| ATA Protocols | UDMA Mode[0-5] | |
| PIO Mode[0-4] | ||
| ATA 100 Cable | 80-Conductor Cable | |
| Internal ATA Connectors | Two 40-Pin Connectors (primary and secondary) | |
|
| ||
| 64-Bit/133-MHZ PCI-X
Dual Channel Ultra320 SCSI HBA (ATA Models with SCSI option and
SCSI Model Standard) 268351-B21 |
SCSI Protocols | Ultra320 SCSI Ultra3 SCSI Wide Ultra2 SCSI Ultra SCSI |
| Electrical Protocol | Low Voltage Differential (LVD) | |
| Drives Supported | Up to 28 | |
| Storage Capacity | Up to 145.6 GB (2 x 72.8 GB 10K HDD) | |
| Data Transfer Method | 64-bit/133-MHz PCI-X bus-master | |
| Maximum Host Bus Transfer Rate | 532 MB/s | |
| Maximum SCSI Transfer Rate | 320 MB/s | |
| Operating System Support | Microsoft Windows 2000, 2003, SBS 2003; Linux Red Hat Advanced Server 2.1, 3; SLES SuSE 7 | |
| External SCSI Connectors | One 68-Pin VHDCI connectors | |
| Internal SCSI Connectors | One SCSI-3 (68-Pin) for Channel A | |
|
| ||
| Integrated Dual Broadcom 5704 10/100/1000 NICs (Wake on LAN and PXE capable) | Network Interface |
10Base-T/100Base-TX/1000Base-TX | |
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3 1000Base-T | |||
| IEEE 802.3 100Base-TX | |||
| Data Transfer Method | 64-bit, 133MHz PCI(X)1.0 | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Full-Duplex) | 2000 Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) |
|
| 10/100/1000Base-TX | Category 5 UTP (2 Pair); up to 328 ft (100 m) |
||
|
|
|||
|
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. AMD, Opteron, and Hyper-Transport are trademarks of AMD Corporation in the United States and other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |