Overview
|
HP AlphaServer/AlphaStation ES47 Tower, AlphaServer ES47, and AlphaServer ES80 Systems
|
|
|
|||||||||||||||||
| At A Glance |
| AlphaServer ES47/ES80 systems |
|
|
|
| Base Systems - Contents |
| Step 1 | Requirements | |
| Step 1a | System Requirements | |
| Step 1b | Configuration Requirements for Partitions | |
| Step 1c | Licensing Systems for Both OpenVMS and Tru64 UNIX | |
| Step 1d | System Management Hardware/Software Requirements | |
| Step 2 | Base System - Mandatory | |
| Step 3 | CPU Building Blocks - Mandatory | |
| Step 4 | Memory Options - Mandatory | |
| Step 5 | System Disk and Load Devices - Optional | |
| Step 6 | External I/O Building Block Drawers for System Expansion - Optional | |
| Step 7 | Packaging and Power - Mandatory Choice | |
| Step 7a | H9A40/H9A45 Racks | |
| Step 7b | 10000 Series Rack | |
| Step 7c | Tower Enclosure or Other 19-inch RETMA Standard Racks | |
| ES/GS Common Options - Hardware Options & Peripherals, Software, and Services | ||
| Upgrades | ||
| Technical Specifications | ||
|
|
Standard Features
| Processor | Up to 8 Alpha 21364 EV7 processors at 1150 MHz and 1000 MHz | ||
|
|
|||
| Cache Memory | Cache Memory 1.75-MB ECC L2 on-chip cache, 7-way set associative | ||
|
|
|||
| Architecture |
Glue-less processor-to-processor multiprocessor architecture constructed from a set of basic components:
|
||
|
|
|||
| CPUs, Memory, and I/O slots |
ES47 Tower
|
ES47
|
ES80 Model 8
|
| Maximum CPUs supported |
2
|
4
|
8
|
| Maximum memory supported |
16 GB
|
32 GB
|
64 GB
|
| Maximum PCI/PCI-X slots supported |
5
|
32
|
64
|
| Maximum AGP slots supported |
1
|
4
|
8
|
| Storage Controller | Integrated Ultra3 SCSI controller for internal disk drives (One per System Building Block Drawer) |
|
|
|
| Interfaces | USB | One Dual USB port per 2P System Building Block Drawer |
| Server Management | Server Management LAN Connection to a single 2P System Building Block Drawer or to the Cable/DSL hub for a system with more than one Building Block Drawer. | |
| Serial | One MBM serial connection per 2P System Building Block Drawer | |
|
|
||
| Form Factor | ES47 | Tower | ||
| ES47 and ES80 | Rack, 34U or 41U | |||
|
|
||||
| Boot/Diagnostic Devices | Load Device | One slim-line DVD/CD-RW drive NOTE: Only bootable CD media is supported for firmware and operating system booting. Bootable DVD media is not supported. |
|
| Hard Drives | Choice of 18.2/36.4/72.8/146-GB/300-GB SCSI disk drives | ||
|
|
|||
| Power Supplies | Two @208V (700-Watt @120V) 48V
auto-sensing power supplies, hot swappable, N+1 Racks require power distribution units, North America or International variant |
|
|
|
| OS Support | Tru64 UNIX V5.1B + IPK, or later AlphaServer ES47/ES80 Tru64 UNIX systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server OpenVMS V7.3-1 plus Update Kit, or later AlphaServer ES47/ES80 OpenVMS systems include pre-installed software, Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS |
| Linux: For information on Linux distributions for Alpha, go to http://www.alphalinux.org/ | |
|
|
|
| Service and Support | Protected by HP Services including a 1-year on-site hardware warranty. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support. |
|
|
Systems
| Step 1 - Requirements |
|
|
| Step 1a - System Requirements | |
|
|
|
|
Mandatory Purchases: The system cannot function without these options or services - the option or service must be ordered with the system.
Optional Purchases:
Recommended Purchases: System performance or function will be
enhanced if this option or service is ordered.
|
|
|
|
| Step 1b - Requirements for Partitions |
|
|
|
A single AlphaServer ES47/ES80 can be divided into logical hardware partitions as small as two processors, each running an instance of Tru64 UNIX or an instance of OpenVMS. Each partition is allocated its own dedicated "shared-nothing" set of hardware resources: CPU module(s), memory module(s), and I/O. Each hardware partition is viewed as a unique node, from a system point-of-view, with its own instance of Tru64 UNIX or OpenVMS operating system and application software, independent system console, and error log. |
|
|
| Minimum Hardware and Software Required per Hardware Partition |
|
|
|
|
|
| Configuration Guidelines |
|
|
|
|
|
| Step 1c - Licensing Systems for Both OpenVMS and Tru64 UNIX | ||
|
|
||
|
A System requires licenses for both OpenVMS and Tru64 UNIX operating
systems, either for dual O/S boot of the entire system or for different
operating systems in separate hard partitions. To use a second operating
system, order the appropriate base system upgrade license and as many
dual CPU SMP licenses as needed. |
||
|
OpenVMS software base system upgrade for ES47 |
QB-63PAE-AK
|
|
| Tru64 UNIX software base system upgrade for ES47 |
QB-595AK-AB
|
|
| OpenVMS software base system upgrade for ES80 |
QB-63PAG-AC
|
|
| Tru64 UNIX software base system upgrade for ES80 |
QB-595AM-AB
|
|
| OpenVMS Alpha dual CPU SMP license for ES47/ES80 |
QL-MT1A9-6S
|
|
| Tru64 UNIX Alpha dual CPU SMP license for ES47/ES80 |
QL-MT4A9-6S
|
|
|
|
||
| Step 1d - System Management Hardware/Software Requirements | |
|
|
|
|
Each AlphaServer ES47, ES80, and GS1280 system includes System Management software that can significantly enhance and simplify monitoring and control of the system. Use of the System Management software is optional. The software, which runs on a separate Intel or Alpha system, consists of two major components:
|
|
|
|
| Step 2 - Base System - Mandatory | |
|
|
|
Mandatory selection of at least one Base System
required.
|
|||||
| Model | OS | 2 Processor System Building Block Drawers Included | Total CPUs Supported (See Step 3) |
I/O Slots in Base System |
Order No. |
| AlphaServer ES47 Tower | Tru64 UNIX | 1 | 2 |
5 PCI-X, 1 AGP |
DA-20AAA-AB |
| AlphaServer ES47 Tower | OpenVMS | 1 | 2 |
5 PCI-X, 1 AGP |
DY-20AAA-AB |
| AlphaStation ES47 Tower | Tru64 UNIX | 1 | 2 |
5 PCI-X, 1 AGP | DA-20AAA-AC |
| AlphaStation ES47 Tower | OpenVMS | 1 | 2 |
5 PCI-X, 1 AGP | DY-20AAA-AC |
| ES47 Model 2 |
Tru64 UNIX | 1 | 2 |
5 PCI-X, 1 AGP | DA-27AAA-AA |
| ES47 Model 2 |
OpenVMS | 1 | 2 |
5 PCI-X, 1 AGP | DY-27AAA-AA |
| ES47 Model 4 |
Tru64 UNIX | 2 | 4 |
10 PCI-X, 2 AGP | DA-47AAA-AA |
| ES47 Model 4 |
OpenVMS | 2 | 4 |
10 PCI-X, 2 AGP | DY-47AAA-AA |
| ES80 Model 2 |
Tru64 UNIX | 1 | 2 |
5 PCI-X, 1 AGP | DA-20AAA-AA |
| ES80 Model 2 |
OpenVMS | 1 | 2 |
5 PCI-X, 1 AGP | DY-20AAA-AA |
| ES80 Model 4 |
Tru64 UNIX | 2 | 4 |
10 PCI-X, 2 AGP | DA-40AAA-AA |
| ES80 Model 4 |
OpenVMS | 2 | 4 |
10 PCI-X, 2 AGP | DY-40AAA-AA |
| ES80 Model 6 |
Tru64 UNIX | 3 | 6 |
15 PCI-X, 3 AGP | DA-60AAA-AA |
| ES80 Model 6 |
OpenVMS | 3 | 6 |
15 PCI-X, 3 AGP | DY-60AAA-AA |
| ES80 Model 8 |
Tru64 UNIX | 4 | 8 |
20 PCI-X, 4 AGP | DA-80AAA-AA |
| ES80 Model 8 | OpenVMS | 4 | 8 | 20 PCI-X, 4 AGP | DY-80AAA-AA |
|
NOTE: Base systems do
not include CPUs or memory
|
|||||
Step 3 - CPU Building Block Modules Mandatory |
|
|
| Mandatory Configurations | ||
| CPUs | Dual CPU Modules | |
|
ES47 Tower, ES47/ES80 Model 2
|
2 | 1 |
|
ES47/ES80 Model 4
|
4 | 2 |
|
ES80 Model 6
|
6 | 3 |
|
ES80 Model 8
|
8 | 4 |
|
Configuration Guidelines
|
||
|
|
| Full Use CPU Building Block Modules | AlphaServer ES47/ES80 Dual CPU Building Block, 2xEV7 CPUs, 1150 MHz, Tru64 UNIX SMP License |
3X-KN73C-AB
|
| AlphaServer ES47/ES80 Dual CPU Building Block, 2xEV7 CPUs, 1150 MHz, OpenVMS SMP License |
3X-KN73C-AC
|
|
| AlphaServer ES47 Tower Dual CPU Building Block Module, 2xEV7 CPUs, 1150 MHz, Tru64 UNIX SMP License |
3X-KN73C-BB
|
|
| AlphaServer ES47 Tower Dual CPU Building Block Module, 2xEV7 CPUs, 1150 MHz, OpenVMS SMP License |
3X-KN73C-BC
|
|
| AlphaServer ES47/ES80 Dual CPU Building Block, 2xEV7 CPUs, 1000 MHz, Tru64 UNIX SMP License |
3X-KN73A-AB
|
|
| AlphaServer ES47/ES80 Dual CPU Building Block, 2xEV7 CPUs, 1000 MHz, OpenVMS SMP License |
3X-KN73A-AC
|
|
| AlphaServer ES47 Tower Dual CPU Building Block Module, 2xEV7 CPUs, 1000 MHz, Tru64 UNIX SMP License |
3X-KN73A-BB
|
|
| AlphaServer ES47 Tower Dual CPU Building Block Module, 2xEV7 CPUs, 1000 MHz, OpenVMS SMP License |
3X-KN73A-BC
|
|
|
|
||
| Configuration and Use of instant Capacity (iCAP) CPUs |
|
The instant Capacity (iCAP) program gives HP customers the option to purchase add-on CPU modules at a reduced price and install those modules in systems ready to activate instantly when needed for extra computational capacity. To use the iCAP program for AlphaServers:
iCAP CPU Building Block Module + iCAP Enablement = Full Use CPU Building Block Module |
|
|
| iCAP CPU Building Block Modules | AlphaServer ES47/ES80 iCAP Dual CPU Building Block, 1150 MHz, one iCAP CPU and one active CPU, Tru64 UNIX SMP License |
3X-KN73C-CB |
| AlphaServer ES47/ES80 iCAP Dual CPU Building Block, 1150 MHz, one iCAP CPU and one active CPU, OpenVMS SMP License |
3X-KN73C-CC |
|
| AlphaServer ES47 Tower iCAP Dual CPU Building Block Module, one iCAP CPU and one active CPU, 1150 MHz, Tru64 UNIX SMP License |
3X-KN73C-DB |
|
| AlphaServer ES47 Tower iCAP Dual CPU Building Block Module, one iCAP CPU and one active CPU, 1150 MHz, OpenVMS SMP License |
3X-KN73C-DC |
|
| AlphaServer ES47/ES80 iCAP Dual CPU Building Block, 1000 MHz, one iCAP CPU and one active CPU, Tru64 UNIX SMP License |
3X-KN73A-CB
|
|
| AlphaServer ES47/ES80 iCAP Dual CPU Building Block, 1000 MHz, one iCAP CPU and one active CPU, OpenVMS SMP License |
3X-KN73A-CC
|
|
| AlphaServer ES47 Tower iCAP Dual CPU Building Block Module, one iCAP CPU and one active CPU, 1000 MHz, Tru64 UNIX SMP License |
3X-KN73A-DB
|
|
| AlphaServer ES47 Tower iCAP Dual CPU Building Block Module, one iCAP CPU and one active CPU, 1000 MHz, OpenVMS SMP License |
3X-KN73A-DC
|
|
|
|
||
| iCAP Enablement | AlphaServer ES47/ES80 iCAP Enable Single CPU, 1150 MHz Tru64 UNIX |
3X-KN73C-EB
|
| AlphaServer ES47/ES80 iCAP Enable Single CPU, 1150 MHz OpenVMS |
3X-KN73C-EC
|
|
| AlphaServer ES47 Tower iCAP Enable Single CPU, 1150 MHz Tru64 UNIX |
3X-KN73C-FB
|
|
| AlphaServer ES47 Tower iCAP Enable Single CPU, 1150 MHz OpenVMS |
3X-KN73C-FC
|
|
| AlphaServer ES47/ES80 iCAP Enable Single CPU, 1000 MHz Tru64 UNIX |
3X-KN73A-EB
|
|
| AlphaServer ES47/ES80 iCAP Enable Single CPU, 1000 MHz OpenVMS |
3X-KN73A-EC
|
|
| AlphaServer ES47 Tower iCAP Enable Single CPU, 1000 MHz Tru64 UNIX |
3X-KN73A-FB
|
|
| AlphaServer ES47 Tower iCAP Enable Single CPU, 1000 MHz OpenVMS |
3X-KN73A-FC
|
|
|
|
||
| TERMS and DEFINITIONS | |
|
iCAP CPU MODULE |
AlphaServer CPU add-on module including the OpenVMS SMP or Tru64 Unix SMP extension license, end user product warranty, iCAP software, plus limited Rights-to-Access the CPU module and leave inactive until First Use. |
| FIRST USE |
First Use takes place when one or more processors on the iCAP CPU Module are activated for permanent use. Temporary replacement of a failed CPU with an iCAP CPU does not constitute First Use. Activation of an iCAP CPU after deactivation of a full use CPU does not constitute First Use. For example, owners are permitted to deactivate a Full Use CPU in one hard partition of the system and activate an iCAP CPU in another hard partition without First Use of the iCAP CPU. First Use of an iCAP CPU Module is considered to have taken place only when the number of active CPUs in the system is greater than the number of purchased full use CPUs. |
| iCAP ENABLEMENT | Grants full Right-to-Use for a previously purchased iCAP CPU Module. |
| PROGRAM PERIOD | There is no time limit to activate an iCAP CPU. |
|
|
ES Options
| CPU Building Block Module 1 | CPU Building Block Module 2 | ||||||||
| Case | Memory Option | CPU 1 | CPU 2 | CPU 3 | CPU 4 | ||||
| Controller 1 | Controller 2 | Controller 1 | Controller 2 | Controller 1 | Controller 2 | Controller 1 | Controller 2 | ||
|
A |
3X-MS7AB-BA (4x256MB) |
1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| B | 3X-MS7AB-CA (4x512MB) | 1 | - | 1 | - | 1 | - | 1 | - |
|
Memory Application Examples |
|||
|
Configuring memory is a compromise between cost, total memory capacity, and memory bandwidth requirements. The following may be used as guidelines:
|
|||
| Memory Specification |
800 MHz
|
1066 MHz
|
|
|
Use only with the indicated CPU Modules (mandatory)
|
May be used with
EV7 1.15 GHz (3X-KN73C-**) or EV7 1.0 GHz (3X-KN73A-**) |
Must be used only with
EV7 1.15 GHz (3X-KN73C-**) |
|
| 1-GB RDRAM Memory (4x256) Option |
3X-MS7AB-BA
|
3X-MS7AC-BA
|
|
| 1-GB RDRAM Memory (1x256) RAID Option |
3X-MS7AB-BC
|
3X-MS7AC-BC
|
|
| 2-GB RDRAM Memory (4x512) Option |
3X-MS7AB-CA
|
3X-MS7AC-CA
|
|
| 2-GB RDRAM Memory (1x512) RAID Option |
3X-MS7AB-CC
|
3X-MS7AC-CC
|
|
| 4-GB RDRAM Memory (4x1024) Option |
3X-MS7AB-DB
|
3X-MS7AC-DA
|
|
| 4-GB RDRAM Memory (1x1024) RAID Option |
3X-MS7AB-DD
|
3X-MS7AC-DC
|
|
|
|
|||
|
Optional selection of additional load device (one included with Base System) |
||
| DVD/CD-RW Combo Drive | Optional DVD/CD-RW combo drive for AlphaServer ES47/ES80 Systems; one per 2P System Building Block Drawer, minus included load device. |
3X-PBXRD-AA
|
|
|
||
|
|
I/O Module for Connection to CPU in a System Building
Block Drawer
|
I/O Buses
|
I/O Slots |
Dual Redundant Power Supplies
|
USB/Ultra3 SCSI Adapter Card
|
DVD/ |
Universal Slot for Disks
|
Part Number
|
| Standard I/O Drawer, Expansion | 1 | 3 PCI-X 1 AGP 4X |
8 PCI-X 1 PCI, 3.3V; 2 PCI, 5V 1 AGP 4X |
Yes | No | No | None | 3X-BA70A-BA |
| Standard I/O Drawer, Master | 1 | 3 PCI-X 1 AGP 4X |
8 PCI-X 1 PCI, 3.3V; 2 PCI, 5V 1 AGP 4X |
Yes | 1 in PCI 3.3V Slot | 1 | 24 | 3X-BA70A-AA |
| High Performance I/O Drawer, Expansion | 1 standard 3 additional, optional1 |
2 to 8 PCI-X |
2 to 8 PCI-X |
Yes | No | No | None | 3X-BA70B- BA |
| High Performance I/O Drawer, Master | 1 standard 3 additional, optional1 |
2 to 8 PCI-X |
2 to 8 PCI-X |
Yes | 1 in PCI-X Slot | 1 | 24 | 3X-BA70B-AA |
| Add-in I/O Module for High Performance I/O Drawers. Each module supports two PCI-X slots. Up to three modules may be added to the base High Performance I/O Drawer. |
3X-KFMHA-AA
|
|
| I/O cable for connection between ES47/ES80 System Building Block Drawer and I/O Building Block Drawer; select one cable for each drawer ordered and one cable per Add-in I/O Module (3X-KFMHA-AA) if ordered. |
3X-BNPCB-02
|
|
|
NOTES
|
||
|
|
||
| Step 7 - Packaging and Power Mandatory Choice |
|
|
| Step 7a - H9A40/H9A45 Racks |
|
|
|
The H9A40/H9A45 Racks are designed for the AlphaServer ES47/ES80/GS1280
product family. Large cable egresses have been built into the rack roof
to allow for cabling out the top of the rack. These racks are 19-inch
RETMA standard and accept HP StorageWorks, HP ProLiant, DS and other ES
models of HP AlphaServers, plus third-party equipment. Configuration Guidelines
|
![]() |
|
H9A40/H9A45 Racks
|
|
|
| Example configurations for
H9A45 41U, 2m, Rack Requires one three-phase PDU (3X-H7606-AA/AB) or two single-phase PDUs (3X-H7609-DB/EB) |
||||||||||
| ES47/80 Model 2 | ES47/80 Model 4 | ES80 Model 6 |
ES80 Model 8 | I/O Expansion Drawers |
DS43xx Storage Works Shelves |
Hubs for System Manage- ment |
3 Phase PDU, 3X-H7606-AA/AB | Total Space Used in U's | Unused Space in 41U Rack | |
|
Size in U's
|
4 | 8 | 12 | 16 | 4 | 3 | 1 | 2.5 | ||
|
One Model 2
|
1 | 0 | 0 | 1 | 1 | 8 | 33 | |||
|
Max Model 2's
|
7 | 0 | 0 | 7 | 1 | 38 | 3 | |||
|
Max Model 2's with I/O Drawers
|
4 | 4 | 0 | 4 | 1 | 39 | 2 | |||
|
One Model 4
|
1 | 0 | 0 | 1 | 1 | 12 | 29 | |||
|
Max Model 4's
|
4 | 0 | 0 | 4 | 1 | 39 | 2 | |||
|
Max Model 4's with I/O Drawers
|
2 | 4 | 1 | 2 | 1 | 40 | 1 | |||
|
One Model 6
|
1 | 0 | 0 | 1 | 1 | 16 | 25 | |||
|
Max Model 6's
|
2 | 0 | 4 | 2 | 1 | 41 | 0 | |||
|
Max Model 6's with I/O Drawers
|
1 | 3 | 4 | 1 | 1 | 40 | 1 | |||
|
One Model 8
|
1 | 0 | 0 | 1 | 1 | 20 | 21 | |||
|
Max Model 8's
|
2 | 0 | 1 | 2 | 1 | 40 | 1 | |||
|
Max Model 8's with I/O Drawers
|
1 | 4 | 1 | 1 | 1 | 39 | 2 | |||
|
NOTE: For AC feed redundancy on any configuration
listed above, order a second three-phase PDU (3X-H7606-AA/AB) or third
and fourth single-phase PDUs (3X-H7609-DB/EB).
|
||||||||||
|
|
| Example configurations for
H9A40 34U, 1.7m, Rack Requires one three-phase PDU (3X-H7606-AA/AB) or two single-phase PDUs (3X-H7609-DB/EB) |
||||||||||
| ES47/80 Model 2 | ES47/80 Model 4 | ES80 Model 6 |
ES80 Model 8 | I/O Expansion Drawers |
DS43xx Storage Works Shelves |
Hubs for System Manage- ment |
3 Phase PDU, 3X-H7606-AA/AB | Total Space Used in U's |
Unused Space in 34U Rack |
|
|
Size in U's
|
4 | 8 | 12 | 16 | 4 | 3 | 1 | 2.5 | ||
|
One Model 2
|
1 | 0 | 0 | 1 | 1 | 8 | 26 | |||
|
Max Model 2's
|
6 | 0 | 0 | 6 | 1 | 33 | 1 | |||
|
Max Model 2's with I/O Drawers
|
3 | 3 | 1 | 3 | 1 | 33 | 1 | |||
|
One Model 4
|
1 | 0 | 0 | 1 | 1 | 12 | 22 | |||
|
Max Model 4's
|
3 | 0 | 1 | 3 | 1 | 33 | 1 | |||
|
Max Model 4's with I/O Drawers
|
1 | 2 | 4 | 1 | 1 | 32 | 2 | |||
|
One Model 6
|
1 | 0 | 0 | 1 | 1 | 16 | 18 | |||
|
Max Model 6's
|
2 | 0 | 1 | 2 | 1 | 32 | 2 | |||
|
Max Model 6's with I/O Drawers
|
1 | 3 | 2 | 1 | 1 | 34 | ||||
|
One Model 8
|
1 | 0 | 0 | 1 | 1 | 20 | 14 | |||
|
Max Model 8's with I/O Drawers
|
1 | 3 | 0 | 1 | 1 | 32 | 2 | |||
|
NOTE: For AC feed redundancy on any configuration
listed above, order a second three-phase PDU (3X-H7606-AA/AB) or third
and fourth single-phase PDUs (3X-H7609-DB/EB).
|
||||||||||
|
|
| H9A40/H9A45 Racks | 41U, 2m Rack, carbon black - without OCP, with sidewalls - includes 200mm rack extender |
3X-H9A45-ZD
|
| 34U, 1.6m Rack, carbon black - without OCP, with sidewalls - includes 200mm rack extender |
3X-H9A40-ZA
|
|
| Factory Integration - Mandatory for H9A45/H9A40 Rack | Factory Integration of systems and storage
devices assembled and configured in rack enclosure in predefined locations |
YS-ASCAA-AA
|
|
Cable/DSL Hub - Optional
One required for each additional ES47/ES80 system, after the first, in the same rack. |
Cable/DSL 8-port Hub - required when more than one system is mounted in the same H9A40/H9A45 Rack |
3X-DGHUB-AA
|
| Power Distribution Units - Mandatory for H9A45/H9A40 Rack | ||
| Three-phase PDU,
One Mandatory plus One Optional (for Dual AC feed redundancy) |
Three-phase PDU for North America/Japan, 120/208V Y or 200V, 30A NEMA L21-30P plug; 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AA
|
| Three-phase PDU for International, 380/415V Y, IEC 309 32A; 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AB
|
|
|
or
|
||
| Single-phase PDU,
Two Mandatory plus Two Optional (for Dual AC feed redundancy) |
Single-phase PDU for North America/Japan 200-240V 20A input plug NEMA L620P; 16 outlets |
3X-H7609-EB
|
| Single-phase PDU for International, 240V 20A input plug IEC309, 16 outlets |
3X-H7609-DB
|
|
| NOTE: The 3X-H7606-AA PDU uses an L21-30P 30 amp plug, Hubbell 2811, a 4 pin connector. | ||
|
|
||
| Step 7b - HP Rack 10000 G2 Series | ||
|
|
||
|
The HP Rack 10000 Series were designed to the19-inch RETMA standard.
The Racks accommodate all HP equipment (ProLiant, Alpha Systems, StorageWorks,
UPS, and PDUs) in addition to select third-party equipment. Configuration Guidelines
NOTE: The ES47/80 system and Rack 10000 G2 Series will ship separately. Installation and integration of the ES47/80 into the rack by HP requires purchase of field Installation Service. |
||
![]() |
||
| 10000 G2 Series Rack, 42U | 10000 G2 Series Rack, 36U | 10000 G2 Series Rack, 22U |
| Dimension "A" 78.838 [2002.50] | Dimension "A" 68.338 [1735.78] | Dimension "A" 43.838 [1113.48] |
| Dimension "B" 24.125 [612.77] | Dimension "B" 24.125 [612.77] | Dimension "B" 24.125 [612.77] |
|
|
||
| Example configurations for
H9A40 34U, 1.7m, Rack Requires one three-phase PDU (3X-H7606-AA/AB) or two single-phase PDUs (3X-H7609-DB/EB) |
||||||||||
| ES47/80 Model 2 | ES47/80 Model 4 | ES80 Model 6 |
ES80 Model 8 | I/O Expansion Drawers |
DS43xx Storage Works Shelves |
Hubs for System Manage- ment |
3 Phase PDU, 3X-H7606-AA/AB | Total Space Used in U's |
Unused Space in 42U Rack |
|
|
Size in U's
|
4 | 8 | 12 | 16 | 4 | 3 | 1 | 2.5 | ||
|
One Model 2
|
1 | 0 | 0 | 1 | 1 | 8 | 34 | |||
|
Max Model 2's
|
7 | 0 | 0 | 7 | 1 | 38 | 4 | |||
|
Max Model 2's with I/O Drawers
|
4 | 4 | 0 | 4 | 1 | 39 | 3 | |||
|
One Model 4
|
1 | 0 | 0 | 1 | 1 | 12 | 30 | |||
|
Max Model 4's
|
4 | 0 | 0 | 4 | 1 | 39 | 3 | |||
|
Max Model 4's with I/O Drawers
|
2 | 4 | 1 | 2 | 1 | 40 | 2 | |||
|
One Model 6
|
1 | 0 | 0 | 1 | 1 | 16 | 26 | |||
|
Max Model 6's
|
2 | 0 | 4 | 2 | 1 | 41 | 1 | |||
|
Max Model 6's with I/O Drawers
|
1 | 3 | 4 | 1 | 1 | 40 | 2 | |||
|
One Model 8
|
1 | 0 | 0 | 1 | 1 | 20 | 22 | |||
|
Max Model 8's
|
2 | 0 | 1 | 2 | 1 | 40 | 2 | |||
|
Max Model 8's with I/O Drawers
|
1 | 4 | 1 | 1 | 1 | 39 | 3 | |||
|
NOTE: For AC feed redundancy on any configuration
listed above, order a second three-phase PDU (3X-H7606-AA/AB) or third
and fourth single-phase PDUs (3X-H7609-DB/EB).
|
||||||||||
|
|
| 10000 G2 Series Rack | 10000 G2 Series 42U Rack mandatory selection of three-phase or two single-phase Power Distribution Units required |
AF004A
|
| Rack Kit Mandatory for 10000 G2 Series Rack |
Order one per 2P System Building Block Drawer for mounting in 10000 G2 Series Rack |
CK-BA60B-AR
|
| Stabilizer Kit - Mandatory | Order one per 10000 G2 Series Rack |
3R-A6892-AA
or AF064A |
| Side Panel Kit Mandatory
Choice of Side Panel Kit or Baying Kit for 10000 G2 Series Rack |
Order one per 10000 G2 Series Rack |
AF054A
|
| Baying Kit Mandatory Choice of Side Panel Kit or Baying Kit for 10000 G2 Series Rack |
Used to join two or more Series 10000 G2 Racks |
3R-A3895-AA or 248931-B21
|
| Cable/DSL Hub Mandatory for each ES47/ES80 system mounted in a 10000 G2 Series Rack | Cable/DSL 8-port Hub required |
3X-DGHUB-AA
|
| Power Distribution Units Mandatory for 10000 G2 Series Rack | ||
| Three-phase PDU,
One Mandatory plus One Optional (for Dual AC feed redundancy) |
Three-phase PDU for North America/Japan, 120/208V Y or 200V, 30A NEMA L21-30P plug; 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AA
|
| Three-phase PDU for International, 380/415V Y, IEC 309 32A; 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AB
|
|
|
or
|
||
| Single-phase PDU, Two Mandatory plus Two Optional (for Dual AC feed redundancy) |
Single-phase PDU for North America/Japan 200-240V 20A input plug NEMA L620P; 16 outlets |
3X-H7609-EB
|
| Single-phase PDU for International, 240V 20A input plug IEC309, 16 outlets |
3X-H7609-DB
|
|
|
|
||
| Step 7c Tower Enclosure or Other 19-inch RETMA Standard Racks | ||
|
|
||
| ES47 Tower Enclosure | ||
| Mandatory selection of two power cords required for each ES47 Tower system ordered. | ||
| North America, 110V |
BN26J-1K
|
|
| North America, 200 to 240V, 75 inch |
BN18J-1K
|
|
| North America, 200 to 240V, 108 inch |
3X-BN64A-1C
|
|
| Australia, New Zealand, 2.5-meter |
3R-A6023-AA
|
|
| Central Europe, 2.5-meter |
BN19C-2E
|
|
| Denmark, 2.5-meter |
BN19K-2E
|
|
| Egypt, India, South Africa, 2.5-meter |
BN19S-2E
|
|
| Israel, 1.9-meter |
3R-A6883-AA
|
|
| Italy, 2.5-meter |
BM19M-2E
|
|
| Japan, 2.5-meter, Dentori approved |
3X-BN46F-02
|
|
|
|
||
| ES47/ES80 Systems in Other 19-inch RETMA Standard Racks | ||
|
AlphaServer ES47/ES80 rackmount systems may be ordered without a rack in order to mount in already installed HP racks, or other 19-inch RETMA standard racks. See Rack Specifications and Rackmount Kits in the ES/GS Common Options section of this QuickSpec for details on HP rack dimensions and a list of different rack mount kits that work with HP racks. Configuration Guidelines
|
||
| Cable/DSL Hub - Mandatory for each ES47/ES80 system | Cable/DSL 8-port Hub - required |
3X-DGHUB-AA
|
|
|
ES/GS Common Options
|
Hardware Options & Peripherals, Software, and
Services for |
| At A Glance |
|
| ES/GS Common Options Contents | |
| Reference 1 | I/O Capacity for AlphaServer ES47/ES80 and AlphaServer GS1280 Systems |
| Reference 2 | Adapter to Peripheral Cross Connect Table |
| Reference 3 | Rack Specifications and Rackmount Kits |
| Step 1 | Networks and Communications Optional |
| Step 2 | Memory Channel Optional |
| Step 3 | Storage Adapters/Controllers Optional |
| Step 4 | StorageWorks Enclosures for Disks and Tapes Optional |
| Step 5 | Disks Optional |
| Step 6 | Storage Systems Optional |
| Step 7 | Tape Drives Optional |
| Step 8 | Tape Storage Systems Optional |
| Step 9 | Storage Network Switches, Hubs, and Interconnects Optional |
| Step 10 | Keyboards, Mouse, Monitors, Power Cords Optional |
| Step 11 | Graphics Support Optional |
| Step 12 | System Software Optional |
| Step 13 | Hardware and Software Support Services Optional |
|
|
| Reference 1 I/O Capacity for AlphaServer ES47/ES80 and AlphaServer GS1280 Systems |
|
AlphaServer ES47/ES80 and GS1280 systems offer three types of I/O bus standards for adapters and controllers. |
||
|
1.
|
PCI-X Peripheral Component Interconnect Extended is a computer bus interface standard for connecting a microprocessor and attached devices. PCI-X doubles the speed and amount of data exchanged between the computer processor and peripherals from the predecessor PCI bus. PCI-X is backwards-compatible, meaning that users can, for example, install a PCI-X card in a standard PCI slot but expect a decrease in speed to 66 MHz or 33 MHz. Users can also use both PCI and PCI-X cards on the same PCI-X bus, but the bus will run at the speed of the slowest card. PCI-X is more fault tolerant than PCI. For example, PCI-X is able to reinitialize a faulty card or take it offline before computer failure occurs. | |
|
2.
|
PCI Peripheral Component Interconnect is a computer bus interface standard for connecting a microprocessor and attached devices. | |
|
3.
|
AGP 4 Accelerated Graphics Port (AGP) is an interface specification that enables 3-D graphics to display quickly. It is especially useful in conjunction with three-dimensional (3D) video, and sophisticated scientific and engineering graphics programs. AGP runs at several times the bus speed of conventional Peripheral Component Interconnect (PCI). Because of this, the data transfer rate using AGP is significantly greater than with PCI video cards. The AGP 4X mode provides high performance levels with a peak bandwidth of 1066 MB/s. AGP 4X mode is a superset to the 1X and 2X modes; thus, all components supporting AGP 4X must also support 1X and 2X modes. | |
| The following table presents the matrix of maximum, theoretical I/O throughput for the different standards. Actual I/O throughput will be less than calculated because of protocol overhead and contention for bus capacity. | ||
| Calculated Maximum Throughput |
32-bit data path
|
64-bit data path
|
|
| PCI, 33 MHz |
0.133 GB/s
|
0.267 GB/s
|
|
| PCI or PCI-X, 66 MHz |
0.267 GB/s
|
0.533 GB/s
|
|
| PCI-X, 100 MHz |
N/A
|
0.8 GB/s
|
|
| PCI-X, 133 MHz |
N/A
|
1.067 GB/s
|
|
| Calculated Maximum Throughput |
1X
|
2X
|
4X
|
| AGP |
0.133 GB/s
|
0.267 GB/s
|
1.067 GB/s
|
| Overall System Capacities for I/O Adapters and Controllers |
|
ES47 Tower or Workstation
|
ES47
|
ES80
|
GS1280
|
|
| Maximum Hard Partitions per system |
1
|
2
|
4
|
32
|
|
Maximum Quantity Tested & Supported
|
||||
|
per system
|
per system
|
per system
|
per hard partition: per system
|
|
| Maximum 2P Building Block Drawers per System |
1
|
2
|
4
|
N/A
|
| PCI-X/PCI slots in 2P Drawers |
5
|
10
|
20
|
N/A
|
| 133-MHz PCI-X/PCI slots in 2P Drawers | 2 | 4 | N/A | |
| AGP slots in 2P Drawers |
1
|
2
|
4
|
N/A
|
| Maximum External I/O Connections |
0
|
2
|
4
|
32 : 64
|
| Maximum Standard I/O Drawers (One I/O connection per drawer) |
0
|
2
|
4
|
32 : 64
|
| PCI-X/PCI slots in Standard I/O Drawers |
|
18
|
36
|
288 : 576
|
| 5V PCI slots in Standard I/O Drawers |
|
4
|
8
|
64 : 128
|
| AGP slots in Standard I/O Drawers |
|
2
|
4
|
32 : 64
|
| Maximum High Performance I/O Drawers (One I/O connection per drawer) |
0
|
2
|
4
|
32 : 64
|
| Maximum High Performance I/O Drawers (Four I/O connections per drawer) |
0
|
1
|
1
|
8 : 16
|
| 133-MHz PCI-X/PCI slots in High Performance I/O Drawers |
|
4
|
8
|
64 : 128
|
| Total Slots |
per system
|
per system
|
per system
|
per
hard partition: per system |
| PCI-X/PCI slots |
5
|
28
|
56
|
288 : 576
|
| 133-MHz PCI-X/PCI slots | 1 | 4 | 8 | 32: 128 |
| 5V PCI slots |
|
4
|
8
|
32 : 64
|
| AGP slots |
1
|
4
|
8
|
32 : 64
|
| Maximum Possible Slots (PCI-X/PCI plus 5V PCI plus AGP slots) |
6
|
36
|
72
|
384 : 768
|
| I/O for Two-processor System Building Block Drawer used in ES47 and ES80 Systems |
|
|||||
| 2P Building Block Drawer Slot Specifications | |||||
|
Port (Bus) #
|
Slot #
|
Maximum Bus Speed
|
Signal Voltage
|
Bus Loading,
Adapters Installed (contiguously starting with Slot 1) |
Max Bus Speed
|
|
0
|
1
|
133 MHz
|
3.3V
|
1 PCI
1 PCI-X |
66 MHz
133 MHz |
|
1
|
1
|
66 MHz
|
3.3V
|
1 or 2 PCI
3 or 4 PCI 1 to 4 PCI-X |
66 MHz
50 MHz 66 MHz |
|
2
|
66 MHz
|
3.3V
|
|||
|
3
|
66 MHz
|
3.3V
|
|||
|
4
|
66 MHz
|
3.3V
|
|||
|
3
|
1
|
4X AGP
|
1.5V
|
1 AGP
|
4X
|
| Standard I/O Drawer used in ES47, ES80, and GS1280 Systems |
|
| Standard I/O Building Block Drawer Slot Specifications | |||||
|
Port (Bus) #
|
Slot #
|
Maximum Bus Speed
|
Signal Voltage
|
Bus Loading,
Adapters Installed (contiguously starting with Slot 1) |
Max Bus Speed
|
|
0
|
1
|
100 MHz
|
3.3V
|
1 PCI
1 PCI-X 2 or 3 PCI1 |
66 MHz
100 MHz 33 MHz |
|
2
|
33 MHz
|
5.0V3
|
|||
|
3
|
33 MHz
|
5.0V3
|
|||
|
1
|
1
|
133 MHz
|
3.3V
|
1 PCI-X
2 PCI-X 1 or 2 PCI |
133 MHz
100 MHz 66 MHz |
|
2
|
133 MHz
|
3.3V
|
|||
|
2
|
1
|
66 MHz
|
3.3V
|
1 to 3 PCI2
4 or 5 PCI 6 PCI 1 to 5 PCI-X 6 PCI-X |
66 MHz
50 MHz 33 MHz 66 MHz 33 MHz |
|
2
|
66 MHz
|
3.3V
|
|||
|
3
|
66 MHz
|
3.3V
|
|||
|
4
|
66 MHz
|
3.3V
|
|||
|
5
|
66 MHz
|
3.3V
|
|||
|
6
|
66 MHz
|
3.3V
|
|||
|
3
|
1
|
4X AGP
|
1.5V
|
1 AGP
|
4X
|
|
|||||
| High Performance I/O Drawer used in ES47, ES80, and GS1280 Systems |
|
| High-performance I/O Drawer Slots Specifications | ||||||
|
I/O Connection
to EV7 Processor |
Port (Bus) #
|
Slot #
|
Maximum Bus Speed
|
Signal Voltage
|
Bus Loading,
Adapters Installed (contiguously starting with Slot 1) |
Max Bus Speed
|
|
0
|
1
|
Slot 1
|
133 MHz
|
3.3V
|
For each slot
1 PCI 1 PCI-X |
66 MHz 133 MHz |
|
0
|
2
|
Slot 1
|
133 MHz
|
3.3V
|
||
|
1
|
1
|
Slot 1
|
133 MHz
|
3.3V
|
||
|
1
|
2
|
Slot 1
|
133 MHz
|
3.3V
|
||
|
2
|
1
|
Slot 1
|
133 MHz
|
3.3V
|
||
|
2
|
2
|
Slot 1
|
133 MHz
|
3.3V
|
||
|
3
|
1
|
Slot 1
|
133 MHz
|
3.3V
|
||
|
3
|
2
|
Slot 1
|
133 MHz
|
3.3V
|
||
|
|
|
| Reference 2 Adapter to Peripheral Cross Connect Table |
|
|
|
SCSI Ultra3 LVD
|
SCSI Ultra2 LVD
|
Ultra3 SCSI Backplane RAID,
2 or 4 channel |
U320 LVD SCSI Backplane RAID,
2 or 4 channel |
|
|
3X-KZPEA-DB
|
3X-KZPCA-AA
|
3X-KZPDC-BE/DF
|
3X-KZPEC-BF/DG
|
|
| MSA30 Rack Disk & Tape Drive Enclosure |
Yes
|
Yes
|
Yes
|
Yes
|
| 4300 Rack Disk & Tape Drive Enclosure |
Yes
|
Yes
|
Yes
|
Yes
|
| 1U Rackmount Tape Drive Enclosure |
Yes
|
Yes
|
no
|
no
|
| 3U Rackmount Tape Drive Enclosure |
Yes
|
Yes
|
no
|
no
|
| MSA1000 Storage System |
no
|
no
|
no
|
no
|
| HP StorageWorks Enterprise Virtual Arrays; EVA4000; EVA6000; EVA8000 |
no
|
no
|
no
|
no
|
| HP StorageWorks Disk Arrays; xp10000; xp12000 |
no
|
no
|
no
|
no
|
| DAT Tape Drives; 40; 72 |
Yes
|
Yes
|
no
|
no
|
| DLT VS Tape Drives; 80; 160 |
Yes
|
Yes
|
no
|
no
|
| Ultrium LTO Tape Drives; 232; 448; 920, 460; 960 |
Yes
|
Yes
|
no
|
no
|
| SDLT Tape Drive; 320; 600 |
Yes
|
Yes
|
no
|
no
|
| DAT 72/10 Autoloader |
Yes
|
Yes
|
no
|
no
|
| 1/8 Autoloader; Ultrium 232, 448, 960 |
Yes
|
Yes
|
no
|
no
|
| MSL2024/4048 Tape Libraries |
Yes
|
Yes
|
no
|
no
|
| MSL6000 Tape Libraries |
Yes
|
Yes
|
no
|
no
|
| ESL E-Series Tape Libraries |
Yes
|
Yes
|
no
|
no
|
| VSL 6000 Virtual Library System |
no
|
no
|
no
|
no
|
| Cross Connect Table |
2-Gbit Fibre Channel Adapter, single channel, PCI-X
LP10000, FCA2684
|
2-Gbit Fibre Channel Adapter, dual channel, PCI-X LP10000,
FCA2684DC
|
|
DS-A5132-AA
|
DS-A5134-AA
|
|
| MSA30 Rack Disk & Tape Drive Enclosure |
no
|
no
|
| 4300 Rack Disk & Tape Drive Enclosure |
no
|
no
|
| 1U Rackmount Tape Drive Enclosure |
no
|
no
|
| 3U Rackmount Tape Drive Enclosure |
no
|
no
|
| MSA1000 Storage System |
Yes1
|
Yes1
|
| HP StorageWorks Enterprise Virtual Arrays; EVA4000; EVA6000; EVA8000 |
Yes1
|
Yes1
|
| HP StorageWorks Disk Arrays; xp10000; xp12000 |
Yes1
|
Yes1
|
| DAT Tape Drives; 40; 72 |
Yes1
|
Yes1
|
| DLT VS Tape Drives; 80; 160 |
Yes1
|
Yes1
|
| Ultrium LTO Tape Drives; 232; 448; 920, 460; 960 |
Yes1
|
Yes1
|
| SDLT Tape Drive; 320; 600 |
Yes1
|
Yes1
|
| DAT 72/10 Autoloaders |
Yes1
|
Yes1
|
| 1/8 Autoloader; Ultrium 232, 448, 960 |
Yes1
|
Yes1
|
| MSL2024/4048 Tape Libraries |
Yes1
|
Yes1
|
| MSL6000 Tape Libraries |
Yes1
|
Yes1
|
| ESL E-Series Tape Libraries |
no
|
no
|
| VSL 6000 Virtual Library System |
Yes
|
Yes
|
| NOTE 1: Fibre Channel connection to a SCSI tape device requires a Network Storage Router (NSR) (see Step 8) in a Storage Area Network (SAN). | ||
|
|
| Reference 3 Rack Specifications and Rackmount Kits |
|
|
| High-performance I/O Drawer slots specifications: | ||||||
|
HP Racks
|
H9A10
|
H9A15
|
9142
|
10642
|
H9A45-ZA
|
H9A45-ZD
|
|
M-series
|
M-series
|
Series 9000
|
Series 10000
|
For GS1280
(includes Operator Control Panel (OCP)) |
For ES47/80
(no OCP) |
|
| Vertical Rack Capacity |
59.5"
|
71.75"
|
73.5"
|
73.5"
|
71.75"
|
71.75"
|
| (1.75" per Rack Unit) |
34U
|
41U
|
42U
|
42U
|
41U
|
41U
|
| Rail Spacing |
19 inch
|
19 inch
|
19 inch
|
19 inch
|
19 inch
|
19 inch
|
| (side-to-side) |
RETMA
|
RETMA
|
RETMA
|
RETMA
|
RETMA
|
RETMA
|
| Rail Spacing (front-to-back) |
25 inches
|
25 inches
|
29 inches
|
29 inches
|
29 inches
|
29 inches
|
| Hole Pattern |
0.281" Round
|
0.281" Round
|
Euro-Square
|
Euro-Square
|
Euro-Square
|
Euro-Square
|
|
RETMA
|
RETMA
|
RETMA
|
RETMA
|
RETMA
|
RETMA
|
|
| Max Payload (spec'd) |
1000 lbs
|
1000 lbs
|
1200 lbs
|
1600 lbs
|
1600 lbs
|
1600 lbs
|
| (equipment weight only, dynamic) |
454 kg
|
454 kg
|
544 kg
|
720 kg
|
720 kg
|
720 kg
|
| Height |
66.9"
|
78.7"
|
78.7"
|
78.7"
|
78.7"
|
78.7"
|
| (external dim w/o packaging) |
1700 mm
|
2 meters
|
2 meters
|
2 meters
|
2 meters
|
2 meters
|
| Width |
23.6"
|
23.6"
|
23.7"
|
23.7"
|
23.6"
|
23.6"
|
| (external dim w/o packaging) |
600 mm
|
600 mm
|
603 mm
|
603 mm
|
600 mm
|
603 mm
|
| Depth w/o Extender |
36.1"
|
36.1"
|
35.8"
|
39.7"
|
NA
|
39.4"
|
| (external dim w/o packaging) |
916 mm
|
916 mm
|
909 mm
|
1009 mm
|
1000 mm
|
|
| Depth w Rear Extender |
41.5"
|
41.5"
|
39.7"
|
Not Available
|
48.1"
|
Optional
|
| (external dim w/o packaging) |
1054 mm
|
1054 mm
|
1009 mm
|
1222 mm
|
||
| Useable Depth |
31.7"
|
31.7"
|
30"
|
35.25"
|
40.25"
|
32.25"
|
| (front rail to back door) |
804 mm
|
804 mm
|
762 mm
|
895 mm
|
1022 mm
|
819 mm
|
| Usable Depth w/Extender |
37.1"
|
37.1"
|
33.9"
|
NA
|
NA
|
40.25
|
| (front rail to back door) |
943 mm
|
943 mm
|
862 mm
|
1022 mm
|
||
| Side Panels |
Standard
|
Standard
|
Standard
|
Standard
|
Standard
|
Standard
|
| Stabilizer |
Single Deployable
|
Dual Deployable
|
Single Deployable
|
Single Deployable
|
Heavy duty Deployable
|
None
|
| Top Cover |
Vented
|
Vented
|
Vented
|
Vented
|
Vented
|
Vented
|
| Rear Door |
Standard w/Lock
|
Standard w/Lock
|
Standard
|
Split
|
Standard w/Lock
|
Standard w/Lock
|
|
Short
|
Long door
|
|||||
|
w/Lock
|
w/Lock
|
|||||
| Front Door |
Optional
|
Optional
|
Standard
|
Standard
|
Standard
|
Standard
|
|
Kit w/Lock
|
Kit w/Lock
|
w/Lock
|
w/Lock
|
w/Lock
|
w/Lock
|
|
| Front Trim Kit |
Required if
no Front Door
|
Required if
no Front Door
|
Standard
w/Lock
|
Not Available
|
Not Available
|
Not Available
|
| PDUs |
Standard
|
Standard
|
Optional
|
Optional
|
Optional
|
Optional
|
| Joiner Kit (aka Baying Kit) |
Optional
|
Optional
|
Optional
|
Optional
|
NA
|
NA
|
| Shipping Height |
76.4"
|
84.4"
|
84.4"
|
86.22"
|
84.75"
|
84.75"
|
| (external dim with packaging) |
1940 mm
|
2144 mm
|
2144 mm
|
2190 mm
|
2153 mm
|
2153 mm
|
| Shipping Width |
36"
|
36"
|
36"
|
32"
|
43.1"
|
43.1"
|
| (external dim with packaging) |
914 mm
|
914 mm
|
914 mm
|
812.8 mm
|
1096 mm
|
1096 mm
|
| Shipping Depth |
53.75"
|
53.75"
|
48"
|
48"
|
48"
|
48"
|
| (external dim with packaging) |
1366 mm
|
1366 mm
|
1219 mm
|
1219 mm
|
1219 mm
|
1219 mm
|
| Shipping Weight |
325 lbs
|
355 lbs
|
445 lbs
|
284 lbs
|
570 lbs
|
570 lbs
|
| (empty cab with full packaging) |
147 kg
|
161 kg
|
202 kg
|
129 kg
|
259 kg
|
259 kg
|
| RACKMOUNT KITS | ||||||
| DS15 |
3X-PBX01-DA
|
3X-PBX01-DA
|
3X-PBX01-DB
|
3X-PBX01-DB
|
3X-PBX01-DB1
|
3X-PBX01-DB1
|
| DS25 |
3X-BA57R-RA
|
3X-BA57R-RA
|
3X-BA57R-RC
|
3X-BA57R-RC
|
3X-BA57R-RC1
|
3X-BA57R-RC1
|
| ES45 |
BA61R-CR
|
BA61R-CR
|
3X-BA61R-RD
|
3X-BA61R-RD
|
3X-BA61R-RD1
|
3X-BA61R-RD1
|
| ES47 |
No kit available
|
No kit available
|
No kit available
|
CK-BA60B-AR
|
Included
|
Included
|
| ES80 |
No kit available
|
No kit available
|
No kit available
|
CK-BA60B-AR
|
Included
|
Included
|
| Mem. Channel 2 |
3X-BA61R-MC
|
3X-BA61R-MC
|
3X-BA61R-MD
|
3X-BA61R-MD
|
3X-BA61R-MD
|
3X-BA61R-MD
|
| 3U LVD enclosure |
3R-A3804-AA
|
3R-A3804-AA
|
Included
|
Included
|
Included
|
Included
|
| 5U LVD/MSL5000 enclosure |
254795-001
|
254795-001
|
Included
|
Included
|
Included
|
Included
|
| StorageWorks 4315/4354 |
Included
|
Included
|
Included
|
Included
|
Included
|
Included
|
| MSA30/MSA1000 |
3R-A5281-AA
|
3R-A5281-AA
|
Standard
|
Standard
|
Standard
|
Standard
|
| NOTES: |
|
| Description | Device Type | Part Number | Maximum Quantity Tested & Supported | |||
| U=Tru64 UNIX O=OpenVMS L=Redhat V7.2 Linux |
||||||
| per system | per hard partition: per system | |||||
| ES47 Tower Workstation | ES47 | ES80 | GS1280 | |||
|
Ethernet Network Interface Cards
|
||||||
|
Gigabit Ethernet NIC, Twisted-Pair Copper with single-port
RJ45, 10/100/1000 Mbps Use BN25G, BN26M, BN24Q, BN28Q, or equivalent cables
with RJ45 connectors.
|
PCI-X 3.3V, 64 b, 133 MHz |
3X-DEGXA-TR | 5/U 5/O 1/L |
16:28/U 16:28/O 1:2L |
16:56/U 16:56/O 1:4/L |
16:512/U 16:512/O |
|
Gigabit Ethernet NIC, Fiber with duplex-SC connectors,
1000 Mbps only. Use BN34B, or equivalent cables with SC connectors.
|
PCI-X 3.3V, 64 b, 133 MHz |
3X-DEGXA-SR | 5/U 5/O 1/L |
16:28/U 16:28/O 1:2L |
16:56/U 16:56/O 1:4/L |
16:512/U 16:512/O |
|
10/100 Ethernet (dual-port UTP/RJ45s) NIC and Base Module.
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. (Optional,
add-on daughter cards 3X-DE602-TR or 3X-DE602-FR)
|
PCI 3.3V, 64 b, 66 MHz |
3X-DE602-BR | 5/U 5/O 1/L |
8:16/U 8:16/O 1:2L |
8:32/U 8:32/O 1:4/L |
8:256/U 8:256/O |
|
10/100 Ethernet (dual-port UTP/RJ45s) add-on to 3X-DE602-BR
only. Total of four ports for combined 3X-DE602-BR and 3X-DE602-TR modules.
Use BN25G, BN26M, BN24Q, BN28Q, or equivalent cables with RJ45 connectors.
NOTE: 3X-DE602-TR cannot be used
standalone.
|
3X-DE602-TR | |||||
|
Single-port 100 Mbps (MMF/duplex-SC) add-on daughter card
for use with the 3X-DE602-BR. Combined 3X-DE602-BR and 3X-DE602-FR provides
two 10/100 (UTP/RJ45s) and one 100Mbps (MMF/SC) ports. Use BN34B cables.
NOTE: 3X-DE602-FR cannot be used
standalone.
|
3X-DE602-FR | |||||
| Step 1b - Networks and Communications — Optional |
| Description | Device Type | Part Number | Maximum Quantity Tested & Supported | |||
| U=Tru64 UNIX O=OpenVMS L=Redhat V7.2 Linux |
||||||
| per system | per hard partition: per system | |||||
| ES47 Tower Workstation | ES47 | ES80 | GS1280 | |||
|
Synchronous Communications Network Interface Cards
|
||||||
|
Dual-port Intelligent Synchronous Communications NIC;
requires one or two BC3xx sync cables.
|
PCI 3.3V, 32 b, 33 MHz |
3X-PBXDD-AA | 4/U 4/O |
4:8/U 4:8/O |
4:16/U 4:16/O |
4:128/U 4:128/O |
|
Quad-port Intelligent Synchronous Communications NIC;
requires one to four BC3xx sync cables.
|
PCI 3.3V, 32 b, 33 MHz |
3X-PBXDD-AB | 4/U 4/O |
4:8/U 4:8/O |
4:16/U 4:16/O |
4:128/U 4:128/O |
|
Asynchronous Communications Network Interface Cards
|
||||||
|
4-port Async Communications NIC with DB-25 cable
|
PCI 3.3V, 32 b, 33 MHz |
PBXDA-BA | 2/U 2/O |
2:4/U 2:4/O |
2:8/U 2:8/O |
2:64/U 2:64/O |
|
8-port Async Communications NIC
|
PCI 3.3V, 32 b, 33 MHz |
PBXDA-BB | 2/U 2/O |
2:4/U 2:4/O |
2:8/U 2:8/O |
2:64/U 2:64/O |
|
16-port Async Communications Controller and rackmount
16-port distribution box with RJ45 connectors
|
PCI 3.3V, 32 b, 33 MHz |
PBXDA-AC | 2/U 2/O |
2:4/U 2:4/O |
2:8/U 2:8/O |
2:64/U 2:64/O |
| Cables for Ethernet, ATM, Synchronous, and Asynchronous Network Interface Cards | Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-SC connectors. xx = 2E, 4E, 01, 03, 10, 20, 30 for 2.4, 4.5, 1, 3, 10, 20, and 30 meters |
BN34B-xx
|
| Category 5e (4-Unshielded Twisted Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. xx = 0B, 0E, 01, 03, 04, 07 for 0.2, 0.5, 1, 3, 4, and 7 meters |
BN25G-xx
|
|
| Category 5e (4-Twisted Pairs, Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. xx = 0B, 0E, 01, 03, 04, 07 for 0.2, 0.5, 1, 3, 4, and 7 meters |
BN26M-xx
|
|
| Category 5e (4-Unshielded Twisted Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. xx = 0E, 01, 03, 04, 07 for 0.5, 1, 3, 4, and 7 meters |
BN24Q-xx
|
|
| Category 5e (4-Twisted Pairs, Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. xx = 0E, 01, 03, 04, 07 for 0.5, 1, 3, 4, and 7 meters |
BN28Q-xx
|
|
| EIA-530 Single-port synchronous cable |
3X-BC34G-06
|
|
| V.24/EIA-232 Single-port synchronous cable |
3X-BC34L-06
|
|
| V.11/x.21 Single-port synchronous cable |
3X-BC33S-06
|
|
| V.35 Single-port synchronous cable |
3X-BC34T-06
|
|
| RJ45-to-DB-25 Asynchronous Converter Cable |
CXI01-AC
|
|
|
|
||
| Description | Device Type | Part Number | Maximum Quantity Tested & Supported | |||
| U=Tru64 UNIX O=OpenVMS L=Redhat V7.2 Linux |
||||||
| per system | per hard partition: per system | |||||
| ES47 Tower Workstation | ES47 | ES80 | GS1280 | |||
|
Memory Channel Adapter
|
||||||
|
Memory Channel Adapter
|
PCI 5.0/3.3V, 32 b, 33 MHz |
CCMAB-BA | 2/U 2/O |
2:4/U 2:4/O |
2:8/U 2:8/O |
2:64/U 2:64/O |
|
Copper-to-single mode fiber optic converter
|
PCI 5.0/3.3V, 32 b, 33 MHz |
CCMFB-BA | 2/U 2/O |
2:4/U 2:4/O |
2:8/U 2:8/O |
2:64/U 2:64/O |
| Infrastructure for Memory Channel | System Area Network Hub with four line cards; includes BN19P-1K` power cord for Canada, Japan, and U.S. For other regions, order appropriate power cord from list that follows. |
CCMHB-AA
|
| Hub expansion box with no line cards |
CCMHB-BA
|
|
| Expansion line card for CCMHB hub |
CCMLB-AA
|
|
| 1-meter cable for CCMAB and CCMHB |
BN39B-01
|
|
| 4-meter cable for CCMAB and CCMHB |
BN39B-04
|
|
| 7-meter cable for CCMAB and CCMHB |
BN39B-07
|
|
| 10-meter cable for CCMAB and CCMHB |
BN39B-10
|
|
| Rackmount kit (3U) for CCMHB (Memory Channel Hub II); required for mounting in H9A40/H9A45 Cabinets and Series 10000 Racks. |
3X-BA61R-MD
|
|
| Power cord for rackmount CCMHB hub |
BN35S-02
|
|
|
|
||
| Country-specific Power Cords for Standalone MEMORY CHANNEL Hubs | Australia, New Zealand |
3R-A6023-AA
|
| Central Europe |
BN19C-2E
|
|
| Denmark |
BN19K-2E
|
|
| Egypt, India |
BN19S-2E
|
|
| Ireland, United Kingdom |
BN19A-2E
|
|
| Israel |
3R-A6883-AA
|
|
| Italy |
BN19M-2E
|
|
| Japan, 2.5-meter, Dentori approved |
3X-BN46F-02
|
|
| Switzerland |
BN19E-2E
|
|
|
|
||
| Step 3 - Storage Adapters/Controllers — Optional |
|
|
| Description | Device Type | Part Number | Maximum Quantity Tested & Supported | |||
| U=Tru64 UNIX O=OpenVMS L=Redhat V7.2 Linux |
||||||
| per system | per hard partition: per system | |||||
| ES47 Tower Workstation | ES47 | ES80 | GS1280 | |||
|
SCSI Adapters
|
||||||
|
Ultra3 (LVD) SCSI adapter, dual-channel. Requires 3X-BC56J-xx
cable.
Restrictions: HSZxx RAID controllers not supported; Tru64 UNIX requires a graphics adapter to run console utilities (RUN BIOS). |
PCI, 3.3V, 64b, 66 MHz |
3X-KZPEA-DB | 5/U 5/O 1/L Shared Bus |
28:28/U 12:24/O 1:2/L Shared Bus |
32:56/U 12:48/O 1:4/L Shared Bus |
32:576/U 12:384/O 0/L Shared Bus |
|
Ultra2 (LVD) SCSI adapter, single-channel. Requires BN38C-xx
cable.
Restrictions: HSZxx RAID controllers not supported. No support for shared SCSI. |
PCI, 3.3/5.0V Universal,
32b, 33 MHz |
3X-KZPCA-AA | 5/U 5/O 1/L |
8:16/U 8:16/O 1:2/L |
8:32/U 8:32/O 1:4/L |
8:256/U 8:256/O 0/L |
|
Backplane RAID SCSI Controllers
|
||||||
|
U320 LVD SCSI Backplane Raid Controller, 64 bit, 2 Channel
|
PCI-X, 3.3V, 64b 133 MHz |
3X-KZPEC-BF | 5/O | 8:16/O | 8:32/O | 8:256/O |
|
U320 LVD SCSI Backplane Raid Controller, 64 bit, 4 Channel
|
PCI-X, 3.3V, 64b 133 MHz |
3X-KZPEC-DG | 5/O | 8:16/O | 8:32/O | 8:256/O |
|
Ultra3 SCSI, 2-channel, RAID controller
|
PCI, 3.3V, 64b, 66 MHz |
3X-KZPDC-BE | 5/U 5/O 1/L |
8:16/U 8:16/O 1:2/L |
8:32/U 8:32/O 1:4/L |
8:256/U 8:256/O 0/L |
|
Ultra3 SCSI, 4-channel, RAID controller
|
PCI, 3.3V, 64b, 66 MHz |
3X-KZPDC-DF | 5/U 5/O 1/L |
8:16/U 8:16/O 1:2/L |
8:32/U 8:32/O 1:4/L |
8:256/U 8:256/O 0/L |
| Cables for SCSI and Backplane RAID Controllers | Ultra3 SCSI cable, VHDCI to VHDCI;
xx = 02, 03, 04, meters |
3X-BC56J-xx
|
| Ultra2 SCSI 68-pin HD male-to-VHDCI male cable; xx = 02, 03, 05, 10, 20 meters |
BN38C-xx
|
|
|
|
||
| Description | Device Type | Part Number | Maximum Quantity Tested & Supported | |||
| U=Tru64 UNIX O=OpenVMS L=Redhat V7.2 Linux |
||||||
| per system | per hard partition: per system | |||||
| ES47 Tower Workstation | ES47 | ES80 | GS1280 | |||
|
Fibre Channel Controllers
|
||||||
|
2-Gbit Fibre Channel Adapter, single channel, PCI-X
LP10000, FCA2684 |
PCI-X, 3.3/5.0V Universal, 64b, 133 MHz |
DS-A5132-AA | 5/U 5/O |
28:28/U 26:28/O |
56:56/U 26:56/O |
64:576/U 26:576/O |
|
2-Gbit Fibre Channel Adapter, dual channel, PCI-X
LP10000, FCA2684DC |
PCI-X, 3.3/5.0V Universal, 64b, 133 MHz |
DS-A5134-AA | 5/U 5/O |
28:28/U 13:26/O |
32:56/U 13:56/O |
32:576/U 13:416/O |
|
CIPCA Adapter
|
||||||
|
Computer Interconnect (CI) adapter; each CI adapter requires
a Standard I/O Building Block Drawer with 5V PCI slots.
|
PCI, 5V, 32b, 33 MHz, two slots |
CIPCA-BA | 2:2/O | 4:4/O | 12:64/O | |
| Cables for Fibre Channel | Fibre Channel SC-SC cables (BNGBX-xx); xx=02, 03, 05, 10, 15, 30, 50 meters |
BNGBX-xx
|
|
|
||
| Step 4 – StorageWorks Enclosures for Disks and Tapes — Optional | ||
|
|
||
| HP StorageWorks Modular Smart Array 30 Enclosure (formerly known as HP StorageWorks 4400 Enclosure) | ||
| The HP StorageWorks
Modular Smart Array 30 (MSA30) Enclosure is an Ultra320 SCSI disk drive
storage enclosure. The drive carrier is designed to support Ultra320, Ultra3,
and Ultra2 hard drives; and DAT tape drives on the same SCSI bus. StorageWorks
4200 or StorageWorks 4300 may be upgraded to the MSA30. See HP StorageWorks Modular Smart Array 30 Enclosure QuickSpecs for configuration details: http://h18000.www1.hp.com/products/quickspecs/11738_div/11738_div.html See HP StorageWorks Modular Smart Array 30 Multi-Initiator Enclosure QuickSpecs for configuration details: http://h18000.www1.hp.com/products/quickspecs/11967_div/11967_div.html |
||
| Model MSA30, Single-bus | Rackmount, 14-drive enclosure
with single bus, dual power supplies |
3R-A4075-AA
|
| Model MSA30, Dual-bus | Rackmount, 14-drive enclosure
with dual bus, dual power supplies NOTE: Not supported for shared bus operation. |
3R-A4076-AA
|
| Model MSA30 Multi-Initiator (Shared) | Rackmount, 14-drive
enclosure with dual bus, multi-initiator shared access, and dual power supplies.
NOTE: Use SCSI Ultra3 LVD host adapter (3X-KZPEA-DB) for shared bus operation. |
359645-B21
|
|
|
||
| HP StorageWorks 4300 Enclosure | ||
| The HP StorageWorks
Enclosure 4300 is an Ultra3 SCSI disk drive storage enclosure. The drive
carrier is designed to support Ultra3 and Ultra2 hard drives and DAT Tape
Drives on the same SCSI bus. See HP StorageWorks 4300 Enclosure QuickSpecs for configuration details: http://h18000.www1.hp.com/products/quickspecs/10624_div/10624_div.html NOTE: The depth of a 4300 shelf does not allow front and rear mounting. |
||
| Model 4314R | Rackmountable 14-drive enclosure with single bus, single power supply |
DS-SL13R-Ax
|
| Model 4354R | Rackmountable 14-drive enclosure with dual bus, dual power supplies |
DS-SL13R-Bx
|
|
|
||
| HP StorageWorks Rackmount Tape Drive Enclosures | ||
| The 1U and 3U Rackmount
Kits are rackmount tape drive enclosures for direct-attach SCSI backup and
archiving applications. See HP StorageWorks Rack-Mount Tape Drive Kits QuickSpecs for configuration details: http://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.html |
||
| 1U Rackmount Tape Drive Enclosure |
|
A7445B
|
| 3U Rackmount Tape Drive Enclosure |
Wide SCSI LVD rackmount enclosure. Supports up to two internal, full-height
or four internal, half-height devices including:
|
274338-B22
|
|
|
||
| Step 5 - Disks Optional | ||
|
|
||
| HP SCSI Ultra320 Hard Disk Drives (for use in StorageWorks MSA30 and 4300 Enclosures; ES47/80 2P System Building Block Drawer; and I/O Building Block Drawers for ES47/80 and GS1280) | ||
| See HP SCSI Ultra320 Hard Drive Option Kits QuickSpecs for configuration details: http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.html | ||
| 300-GB Pluggable Ultra320 SCSI 10,000 rpm Hard Drive |
3R-A4952-AA
|
|
| 146.8-GB Pluggable Ultra320 SCSI 10,000 rpm Hard Drive |
3R-A3841-AA
|
|
| 72.8-GB Pluggable Ultra320 SCSI 10,000 rpm Hard Drive |
3R-A3839-AA
|
|
| 300-GB Pluggable Ultra320 SCSI 15,000 rpm Hard Drive |
3R-A6726-AA
|
|
| 146.8-GB Pluggable Ultra320 SCSI 15,000 rpm Hard Drive |
3R-A4945-AA
|
|
| 72.8-GB Pluggable Ultra320 SCSI 15,000 rpm Hard Drive |
3R-A3851-AA
|
|
| 36.4-GB Pluggable Ultra320 SCSI 15,000 rpm Hard Drive |
3R-A3849-AA
|
|
|
|
||
| Step 6 – Storage Systems — Optional | ||
|
|
||
| HP StorageWorks Modular Smart Array 1000 | ||
| The HP StorageWorks
Modular Smart Array 1000 is a 2-Gb Fibre Channel storage system designed
for the entry-level to mid-range Storage Area Network (SAN). The MSA1000
combines the array controller shelf and the drive shelf, which holds up
to 14 universal disk drives in a single 4U rackmount enclosure. More storage
can be deployed with the addition of up to two drive enclosures for a maximum
storage capacity of 6 TB when using the146-GB drives. Besides the single-port
2-Gb Fibre Channel I/O module that comes standard, there is an 8-port switch
that mounts internally. The MSA1000 provides Ultra3 SCSI connections to
the hard drives and uses HP Universal Ultra2, Ultra3, and/or Ultra320 drives. See HP StorageWorks Modular Smart Array 1000 Specific for Tru64 UNIX or OpenVMS Only QuickSpecs for configuration details: http://h18000.www1.hp.com/products/quickspecs/11621_div/11621_div.html |
||
| Modular Smart Array 1000 | MSA1000 with 256-MB cache |
201723-B22
|
|
|
||
| HP StorageWorks Enterprise Virtual Array |
|
The HP Enterprise Virtual Array storage array products have been designed for high performance, high capacity, and high availability. These products are supported by a powerful and simple suite of management software. EVA storage is designed for improved storage utilization and scalability. EVA storage offers easy capacity expansion, instantaneous replication, and simplified storage administration. See HP StorageWorks Enterprise Virtual Array QuickSpecs for configuration
details: |
|
|
|
Model
|
EVA4000
|
EVA6000
|
EVA8000
|
EVA8000
with expansion cabinet |
|
Drive Interface
|
Dual ported 2 Gb/s FC-AL |
Dual ported 2 Gb/s FC-AL |
Dual ported 2 Gb/s FC-AL |
Dual ported 2 Gb/s FC-AL |
|
Cache per controller pair
|
4GB | 4GB | 8GB | 8GB |
|
Host ports
|
Four 2 Gb/s FC | Four 2 Gb/s FC | Eight 2 Gb/s FC | Eight 2 Gb/s FC |
|
Device ports
|
Four 2 Gb/s FC-AL |
Four 2 Gb/s FC-AL |
Eight 2 Gb/s FC-AL |
Eight 2 Gb/s FC-AL |
|
Device FC-AL switches
|
0 | 2 | 4 | 4 |
|
Maximum Drives per model
|
56 | 112 | 168 | 240 |
|
|
| HP StorageWorks Disk Array xp10000 | ||
|
The HP StorageWorks Disk Array xp1000 is an enterprise storage system
that supports up to 240 Fibre Channel disk drives with up to 69 TB of
capacity. The xp10000 supports up to 48 Fiber Channel (2-Gb or 4-Gb) interface
connections. |
||
|
|
||
| HP StorageWorks Disk Array xp12000 |
|
The HP StorageWorks Disk Array xp12000 is an enterprise storage system
that supports up to 1152 Fibre Channel disk drives with up to 332 TB of
capacity. The xp12000 supports up to 128 Fiber Channel (2-Gb or 4-Gb)
interface connections. |
|
|
| Step 7 – Tape Drives — Optional | ||
|
|
| HP StorageWorks DAT Tape Drive Family | ||
| The HP StorageWorks
DAT Tape Drives are an entry-level solution for small to medium server storage
backup needs. The DAT Tape Drives have backwards compatibility with previous
DDS technologies. See HP StorageWorks DAT Drives QuickSpecs for configuration details: http://h18000.www1.hp.com/products/quickspecs/11883_div/11883_div.html |
||
| DAT Hot-Plug Tape
Drives (for use in StorageWorks MSA30 and 4300 Enclosures; and ES47/80 2P System Drawer) |
40-GB hot-plug DAT tape drive, uses two Universal storage device slots |
3R-A4745-AA
or Q1546A |
| 72-GB hot-plug DAT tape drive, uses two Universal storage device slots |
3R-A4547-AA
or Q1529A |
|
| DAT Internal Tape
Drives (for use in Rackmount Tape Drive Enclosures) |
40-GB internal DAT tape drive, half-height device (carbon) |
3R-A6831-AA
or C5686C |
| 72-GB internal DAT tape drive, half-height device (carbon) |
3R-A6663-AA
or Q1522B |
|
| DAT External (tabletop)Tape Drives | 40-GB external (tabletop) DAT tape drive |
C5687D
|
| 72-GB external (tabletop) DAT tape drive |
Q1523B
|
|
|
|
||
| HP StorageWorks SDLT Tape Drive Family | ||
| The HP StorageWorks
SDLT Tape Drive is a high-capacity, high-performance streaming tape drive.
The HP StorageWorks SDLT 320-GB Tape Drive is backward read compatible with
DLT Type IV media. The SDLT 600 offers backward-read compatibility to the
DLT VS 160 and to the SDLT 320 and SDLT 220. See HP StorageWorks SDLT Tape Drive Family QuickSpecs for configuration details: http://h18000.www1.hp.com/products/quickspecs/11840_div/11840_div.html |
||
| SDLT Internal Tape
Drives (for use in Rackmount Tape Drive Enclosures) |
320-GB internal SDLT tape drive, full-height device |
257319-B21
|
| 600-GB internal SDLT tape drive, full-height device |
A7518B
|
|
| SDLT External (tabletop) Tape Drives | 320-GB external (tabletop) SDLT tape drive, North America (Carbon) |
257319-001
|
| 320-GB external (tabletop) SDLT tape drive, International (Carbon) |
257319-B31
|
|
| 320-GB external (tabletop) SDLT tape drive, Japan (Carbon) |
257319-291
|
|
| 600-GB external (tabletop) SDLT tape drive, North America |
A7519B
|
|
| 600-GB external (tabletop) SDLT tape drive, Worldwide |
A7520B
|
|
|
|
||
| HP StorageWorks DLT VS Tape Drive Family | ||
|
The HP StorageWorks DLT VS80 Tape Drive is an upgrade drive for current DLT 40 customers, offering a 100% increase in capacity. Utilizing industry standard DLT Type IV Media, the DLT VS80 Tape Drive offers backward-read compatibility with media previously written in the DLT 40 format. The DLT VS80 drive is also read and write compatible with data protection solutions utilizing the HP StorageWorks DLT1 Tape Drive, such as the HP StorageWorks DLT1 1280 SuperLoader, and can be read by the HP StorageWorks SDLT 220 and 320 Tape Drives. See HP StorageWorks DLT VS Family Tape Drive QuickSpecs
for configuration details: |
||
| DLT VS Internal
Tape Drives (for use in Rackmount Tape Drive Enclosures) |
80-GB DLT VS internal tape drive, full-height device, (carbon), Worldwide |
3R-A5071-AA
337699-B21 |
| 160-GB DLT VS internal tape drive, full-height device, (carbon), Worldwide |
A7569B
|
|
| DLT VS External
(tabletop) Tape Drives |
80-GB DLT VS external (tabletop) tape drive, North America (carbon) |
3R-A4982-AA
337699-B22 |
| 80-GB DLT VS external (tabletop) tape drive, International (carbon) |
3R-A4984-AA
337699-B31 |
|
| 160-GB DLT VS external (tabletop) tape drive, North America (carbon) |
A7570B
|
|
| 160-GB DLT VS external (tabletop) tape drive, International (carbon) |
A7571B
|
|
|
|
||
| HP StorageWorks Ultrium LTO Tape Drive Family | ||
|
HP StorageWorks Ultrium tape drives are based on LTO Ultrium format, an open standard with a well-defined four-generation roadmap. See HP StorageWorks Ultrium Full-Height Tape Drives QuickSpecs
for configuration details: |
||
| Ultrium LTO Internal
Tape Drives (for use in Rackmount Tape Drive Enclosures) |
Ultrium 232, 200-GB LTO internal tape drive, half-height device |
DW064A
|
| Ultrium 448, 400-GB LTO internal tape drive, half-height device |
DW016A
|
|
| Ultrium 920, 800-GB LTO internal tape drive, half-height device |
EH841A
|
|
| Ultrium 460, 400-GB LTO internal tape drive, full height device |
Q1518B
|
|
| Ultrium 960, 800-GB LTO internal tape drive, full-height device |
Q1538A
|
|
| Ultrium LTO External (tabletop) Tape Drives | Ultrium 232, 200-GB LTO external (tabletop) tape drive |
DW065B
|
| Ultrium 448, 400-GB LTO external (tabletop) tape drive |
DW017B
|
|
| Ultrium 920, 800-GB LTO external tape drive, half-height device |
EH842A
|
|
| Ultrium 460, 400-GB LTO external (tabletop) tape drive |
Q1520B
|
|
| Ultrium 960, 800-GB LTO external (tabletop) tape drive |
Q1539B
|
|
|
|
||
| Step 8 – Tape Storage Systems — Optional | ||
|
|
| HP StorageWorks DAT Tape Autoloaders | |
|
Backup solution for small to medium companies with limited IT support or remote sites of larger companies. The autoloader includes a single tape drive inside an enclosure that holds ten data cartridges in two removable magazine. HP DDS tape drives are backward read-write compatible with the two previous DDS generations, thus this DDS-4 autoloader also reads and writes DDS-3 and DDS-2. |
|
See HP StorageWorks DAT 72x10 Tape Autoloader QuickSpecs for configuration details: http://h18000.www1.hp.com/products/quickspecs/12486_div/12486_div.html |
|
| DAT 72x10 Autoloader |
AE313A
|
|
|
|
| HP StorageWorks 1/8 Tape Autoloader Family | ||
|
The HP StorageWorks 1/8 Tape Autoloader provides unattended backup in a datacenter rack or on a desk next to the office server. The 1/8 Tape Autoloader in a 2U form factor can house up to eight cartridges. See HP StorageWorks 1/8 Tape Autoloader Family QuickSpecs for configuration details: http://h18000.www1.hp.com/products/quickspecs/11841_div/11841_div.html |
||
| 1/8 Ultrium LTO 232 Autoloader | Table Top |
AA202A
|
| 1/8 Ultrium LTO 448 Autoloader | Table Top |
AA203A
|
| 1/8 Ultrium LTO 960 Autoloader | Table Top |
AA204A
|
| Rack Mount Kit | Use to mount Table Top units in a 19" RETMA rack |
C9268R
|
|
|
||
| HP StorageWorks MSL2024 Tape Library |
|
The HP StorageWorks MSL2024 Tape Library combines compressed capacity (2:1) of up to 19.2 TB and tape library features in a compact 2U form factor. The HP StorageWorks MSL2024 Tape Library offers two 12-slot removable magazines, one mail slot and a barcode reader for efficient media management. See HP StorageWorks MSL2024 Tape Library QuickSpecs for configuration
details: |
| Family Comparison |
MSL2024 Ultrium 960 Tape Library
|
MSL2024 Ultrium 920 Tape Library
|
MSL2024 Ultrium 448 Tape Library
|
| Drive Technology |
Ultrium 960 SCSI
|
Ultrium 920
|
Ultrium 448
|
| Number of Drives |
1
|
1 or 2
|
1 or 2
|
| Capacity (compressed 2:1) |
19.2 TB
|
19.2 TB
|
9.6 TB
|
| Maximum Data Transfer (compressed 2:1) |
160 MB/s
|
240 MB/s (2 drives)
|
96 MB/s (2 drives)
|
| Interface |
4Gb Native Fibre Channel
Ultra320 SCSI LVD/SE |
3Gb/sec SAS
Ultra320 SCSI LVD/SE |
Ultra160 SCSI LVD/SE
|
| HP StorageWorks MSL4048 Tape Libraries |
|
The HP StorageWorks MSL4048 Tape Library provides up to 19.2 TB of storage density in a 4U form factor. Web-based management features reduce the dependencies on local IT resources, allowing multiple sites to be supported centrally. Each library includes four removable 12-slot magazines, and a user configurable 3 slot mail-slot dedicated for import/export of data cartridges. A barcode reader is part of the standard configuration for facilitating media management. See HP StorageWorks MSL4048 Series Tape Libraries QuickSpecs for
configuration details: |
| Family Comparison |
MSL4048 Ultrium 960 FC
|
MSL4048 Ultrium 960
|
MSL4048 Ultrium 920
|
MSL4048 Ultrium 448
|
| Number of Drives |
1 or 2
|
1 or 2
|
1 to 4
|
1 to 4
|
| Capacity (native) |
19.2 TB
|
19.2 TB
|
19.2 TB
|
9.6 TB
|
| Maximum Data Transfer (native) |
288 MB/s ( one drive)
576 MB/s (two drives) |
288 MB/s ( one drive)
576 MB/s (two drives) |
216 MB/s ( one drive)
864 MB/s (four drives) |
86 MB/s (one drive)
346 MB/s (four drives) |
| Interface |
4Gb Native Fibre Channel
|
Ultra320 SCSI LVD/SE |
Ultra320 SCSI LVD/SE
3 Gb/sec SAS |
Ultra160 SCSI LVD/SE
|
| HP StorageWorks MSL6000 Tape Libraries |
|
The MSL6000 Tape Libraries offer storage in two enclosures (5U or 10U form factor), in tabletop or rack configurations. The MSL6000 has the capability for multi-unit scalability. The Libraries support interface connections using Ultra3 LVD SCSI Interface or Fibre Channel (2 Gb). See HP StorageWorks MSL6000 Series Tape Libraries QuickSpecs for
configuration details: |
|
MSL6026
|
MSL6030
|
MSL6052
|
MSL6060
|
|
| Form Factor |
5U
|
5U
|
10U
|
10U
|
| Tape Drives |
SDLT 600
|
Ultrium 460 or 960
|
SDLT 600
|
Ultrium 460 or 960
|
| Number of Drives |
up to 2
|
up to 2
|
up to 4
|
up to 4
|
| Media Slots |
26
|
30
|
52
|
60
|
| Storage per Library, TB |
15.6
|
24
|
31.2
|
48
|
| Libraries per rack |
8
|
8
|
4
|
4
|
| Storage per Rack, TB |
124.8
|
192.0
|
124.8
|
192.0
|
| Interface Connection |
Ultra3 LVD SCSI Interface or
Embedded Fibre (2 Gb) |
Ultra3 LVD SCSI Interface or
Embedded Fibre (2 Gb) |
Ultra3 LVD SCSI Interface or
Embedded Fibre (2 Gb) |
Ultra3 LVD SCSI Interface or
Embedded Fibre (2 Gb) |
| HP StorageWorks EML E-Series Tape Libraries |
|
With up to 16 HP Ultrium tape drives, the EML E-Series offers native throughput of over 4.6 TB/hr. Through the addition of expansion modules, the EML E-Series library scales to 16 drives and 442 slots for maximum performance or 8 drives and 505 slots for maximum capacity. See HP StorageWorks EML E-Series Series Tape Libraries QuickSpecs
for configuration details: |
|
Configuration
|
EML 103e
|
EML 245e
|
EML 442e
Maximum Performance |
EML 505e
Maximum Capacity |
| # of drives possible |
1-4
|
1-8
|
1-16
|
1-8
|
| # of slots |
103
5 in configurable load port |
245
15 in configurable load port |
442
35 in configurable load port |
505
35 in configurable load port |
| Product height within rack |
12U
|
24U
|
40U
|
40U
|
| Maximum Capacity (native) |
41.2
|
98.0 TB
|
176.8 TB
|
202 TB
|
| Maximum throughput (native) |
1.1 TB/hr
|
2.3 TB/hr
|
4.6 TB/hr
|
2.3 TB/hr
|
| HP StorageWorks ESL E-Series Tape Libraries |
|
The HP StorageWorks Enterprise Storage Libraries (ESL) E-Series enterprise tape libraries offer drive and cartridge density and are available in a variety of configurations, with up to 28.4 TB of native Ultrium 960 storage capacity per square foot. Fully integrated into HP StorageWorks Extended Tape Library Architecture (ETLA), HP provides self-aware tape storage designed specifically for the SAN. ETLA also offers remote management of the entire library system including robotics, drives, Interface Controllers, and the Interface Manager management card. See HP StorageWorks ESL E-Series Tape Libraries QuickSpecs for
configuration details: |
|
ESL 712e
|
ESL 322e
|
ESL 630e
|
ESL286e
|
|
| Drive Technology |
Ultrium 960 FC
Ultrium 460 SCSI Ultrium 460 FC |
Ultrium 960 FC
Ultrium 460 SCSI Ultrium 460 FC |
SDLT 320
SDLT 600 |
SDLT 320
SDLT 600 |
| Maximum Cartridge Count |
712
|
322
|
630
|
286
|
| Maximum Drive Count |
24
|
24
|
24
|
24
|
| Maximum Capacity (native) |
284.8 TB
|
128.8 TB
|
189 TB
|
85.8 TB
|
| HP StorageWorks 6000 Virtual Library System |
|
The HP StorageWorks 6000 Virtual Library System (VLS 6000) emulates popular tape libraries and tape drives. By emulating multiple tape drives simultaneously, more backup jobs can be done in parallel resulting in reduced backup times. Additionally, because the data resides on disk, single file restores are exceptionally fast. See HP StorageWorks 6000 Virtual Library System QuickSpecs for
configuration details: |
|
VLS 6105
|
VLS 6109
|
VLS 6510
|
VLS 6518
|
VLS 6840
|
VLS 6870
|
|
| Raw Capacity |
3TB
|
6TB
|
6TB
|
12TB
|
12TB
|
24TB
|
| Maximum Raw Capacity |
6TB
|
12TB
|
12TB
|
24TB
|
48TB
|
96TB
|
| Usable Capacity |
2.5TB
|
4.4TB
|
5TB
|
8.8TB
|
10TB
|
17.6TB
|
| Maximum Usable Capacity |
5TB
|
8.8TB
|
10TB
|
17.6TB
|
40TB
|
70.4TB
|
| Interface 2Gb Fibre
Channel Ports (LC connectors, auto-negotiating) |
Two
|
Two
|
Four
|
Four
|
Four
|
Four
|
| Step 9 – Storage Network Switches, Hubs, and Interconnects — Optional | ||
|
|
||
| Network Storage Routers |
Network Storage Routers
enable multiple host servers to communicate with a SCSI tape device over
a Fibre Channel link. For configuration details, see the Switches, Hubs, and Interconnects QuickSpecs at: http://www.compaq.com/products/quickspecs/north_america/10490.html |
|
|
|
||
| Fibre Channel Switches |
HP supports three product lines
of Fibre Channel switch products that may be used to build SAN fabrics.
Each product line provides certain advantages that apply to specific applications.
For more information on specific switch models and selection, please refer
to Part II in the SAN Design Guidelines referenced on the SAN Infrastructure
page: http://h18006.www1.hp.com/storage/saninfrastructure/index.html The B-Series product line includes a wide range of Fibre Channel switches, described as "SAN switches" and "Core switches." Products in this family include switches from the HP StorageWorks SAN Switch 2/16 to the HP StorageWorks Core Switch 2/64. This product line includes switches with 8, 16, 32, and 64 ports, including both full-function and entry-level models. The HP StorageWorks Core Switch 2/64 includes a pair of independent 64-port switches in a single chassis with a high level internal redundancy. The C-Series product line includes the Cisco MDS 9506 and 9509 Multilayer Directors and the Cisco MDS 9216, 9120, and 9140 Multilayer Fabric Switches. The MDS 9506 is supported with 224 ports, over seven modular chassis consisting of both 16-port and 32-port modules. The MDS 9506 is supported with 128 ports, over four modular chassis consisting of both 16-port and 32-port modules. The MDS 9216 has a basic configuration with 16 ports. It has an expansion slot that supports either a 16- or a 32-port card, for 32 or 48 ports in total. The M-Series Fabric product line includes a wide range of Fibre Channel switches described as "Directors" and "Edge switches." A partial list of products in this family includes the HP StorageWorks Director 2/140 and the HP StorageWorks Edge Switch 2/32. This product line includes switches with 16, 24, 32, 64, and 140 ports internal microcode. The HP StorageWorks Director 2/64 and 2/140 switches have a high level of internal redundancy. |
|
|
|
| Step 10 – Keyboards, Mouse, Monitors, Power Cords – Optional | ||
|
|
| Keyboards - USB Keyboard/Language | Tru64 UNIX | OpenVMS (Note 1) |
| N.A./International keyboard | 3R-A6554-AA | 3X-LK464-A2 |
| Arabic keyboard | 3R-A6540-AA | - |
| Belgian keyboard | 3R-A6541-AA | 3X-LK464-AB |
| BHCSY keyboard | 3R-A6542-AA | - |
| Canadian/English keyboard | - | 3X-LK464-AQ |
| Canadian/French keyboard | 3R-A6543-AA | 3X-LK464-AC |
| Cyrillic keyboard (Russian) | 3R-A6544-AA | 3X-LK464-BT |
| Czech keyboard | 3R-A6545-AA | 3X-LK464-BV |
| Danish keyboard | 3R-A6546-AA | 3X-LK464-AD |
| Dutch keyboard | 3R-A6547-AA | 3X-LK464-AH |
| Finnish keyboard | 3R-A6548-AA | 3X-LK464-AF |
| French keyboard | 3R-A6549-AA | 3X-LK464-AP |
| German keyboard | 3R-A6550-AA | 3X-LK464-AG |
| Greek keyboard | 3R-A6551-AA | 3X-LK464-BH |
| Hebrew keyboard | 3R-A6552-AA | 3X-LK464-AT |
| Hungarian keyboard | 3R-A6553-AA | 3X-LK464-BQ |
| International keyboard | 3R-A6554-AA | - |
| Italian keyboard | 3R-A6555-AA | 3X-LK464-AI |
| Japanese keyboard | 3R-A6556-AA | - |
| Korean keyboard | 3R-A6557-AA | - |
| Latin-American keyboard | 3R-A6558-AA | - |
| Norwegian keyboard | 3R-A6559-AA | 3X-LK464-AN |
| Polish keyboard | 3R-A6560-AA | 3X-LK464-BP |
| Portuguese keyboard | 3R-A6561-AA | 3X-LK464-AV |
| Romanian keyboard | - | 3X-LK464-BL |
| Simplified Chinese keyboard | 3R-A6562-AA | - |
| Slovak keyboard | 3R-A6563-AA | 3X-LK464-CZ |
| Spanish keyboard | 3R-A6564-AA | 3X-LK464-AS |
| Swedish keyboard | 3R-A6565-AA | 3X-LK464-AM |
| Swiss/French keyboard | 3R-A6566-AA | 3X-LK464-AK |
| Swiss/German keyboard | - | 3X-LK464-AL |
| Traditional Chinese keyboard | 3R-A6567-AA | - |
| Thai keyboard | 3R-A6568-AA | - |
| Turkish Q keyboard | 3R-A6569-AA | 3X-LK464-BU |
| Turkish/F keyboard | - | 3X-LK464-BW |
| UK keyboard | 3R-A6570-AA | 3X-LK464-A2 |
| Yugoslavian keyboard | - | 3X-LK464-BY |
| NOTE 1: OpenVMS keyboard (3X-LK464-xx) comes with PS/2 and USB connectors | ||
|
|
||
| Rackmount Keyboard/Drawer and Keyboard/Monitor Options | PS2 to USB Converter – allows for connection of a PS2 keyboard and/or mouse to an AlphaServer ES47 System |
3R-A4495-AA
|
| HP Rackmount Flat Panel Monitor – TF T721OR 17-inch (17-inch viewable image area) 1U rackmount flat panel display. 0.264mm pixel pitch, 1280 x1024 @60/75 Hz high and low voltage power cords, Worldwide |
3R-A5187-AA
|
|
| Keyboard, Video, Mouse (KVM) Switches | ||
| HP Server 1 x 8-Port KVM Switch (Tru64 UNIX and OpenVMS) |
336044-B21
|
|
| USB Interface Adapter – 1 pack (Mandatory option with 336044-B21) |
336047-B21
|
| For more information, refer to
the Release Notes at: http://h18002.www1.hp.com/alphaserver/download/es47_es80_gs1280_console_Switch _Release_Notes.pdf http://h18002.www1.hp.com/alphaserver/download/es47_es80_gs1280_console_Switch _Release_Notes.html |
| CAT5e Cables | ||
| 3 foot (1m) – 4 pack |
263474-B21
|
|
| 6 foot (2m) – 8 pack |
263474-B22
|
|
| 12 foot (4m) – 8 pack |
263474-B23
|
|
| 20 foot (6m) – 4 pack |
263474-B24
|
|
| 40 foot (12m) – 1 pack |
263474-B25
|
|
| Integrated Keyboard and Drawer | ||
| Integrated Keyboard and Drawer (1U), North America |
3R-A4404-AA
|
|
| Integrated Keyboard and Drawer (1U), International |
3R-A4405-AA
|
|
| Integrated Keyboard and 17" Monitor (TFT7600RKM) | ||
| Integrated Keyboard and Monitor, North America |
AG052A
|
|
| Integrated Keyboard and Monitor, United Kingdom |
AG053A
|
|
| Integrated Keyboard and Monitor, Germany |
AG054A
|
|
| Integrated Keyboard and Monitor, France |
AG055A
|
|
| Integrated Keyboard and Monitor, Italy |
AG056A
|
|
| Integrated Keyboard and Monitor, Spain |
AG057A
|
|
| Integrated Keyboard and Monitor, International |
AG066A
|
|
|
|
||
| Mouse | 3-button mouse USB |
3R-A6641-AA
|
|
|
||
| Monitors |
|
Configuration Guidelines
|
|
|
| Carbon/Silver Monitors | V7650 17-inch (16-inch viewable image size) 0.24mm FST multi-frequency color monitor, 2-tone (carbon/silver), VGA to 1024 x 768 @85 Hz, MPRII/TCO 03/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable |
3R-A5853-AA
|
| Same as above, with Euro power cord |
3R-A5854-AA
|
|
| Same as above, Taiwan, NA power cord |
3R-A5855-AA
|
|
| Same as above, PRC power cord, CCIB |
PF996AA#AB2
|
|
| Same as above, Southern Hemisphere with Australia/New Zealand power cord |
PF996AA#ABG
|
|
|
|
||
| Carbon/Silver Flat Panel Monitors | L2065, 20-inch (20.1-inch viewable image area) flat panel monitor 0.255mm pixel pitch, 1600 x 1200 @60 Hz, A + D, TCO 03, Energy Star compliant, four video input connectors, (VGA, DVI-I, composite video and s-video), North America power cord, VGA and DVI-I cables |
3R-A6701-AA
|
| L2065, 20-inch (20.1-inch viewable image area) flat panel monitor 0.255mm pixel pitch, 1600 x 1200 @60 Hz, A + D, TCO 03, Energy Star compliant, four video input connectors, (VGA, DVI-I, composite video and s-video), Euro power cord, VGA and DVI-I cables |
3R-A6702-AA
|
|
| L1506, 15" (15" viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @60 Hz, multi-mode support, MPR-II/TCO 03/Energy Star compliant, NA power cord, VGA cable |
3R-A6515-AA
|
|
| Same as above, Euro power cord |
3R-A6516-AA
|
|
|
|
||
| Monitor Power Cords | North America, 120V, 75-inch |
BN26J-1K
|
| Australia, New Zealand, 2.5-meter |
3R-A6023-AA
|
|
| Central Europe, 2.5-meter |
BN19C-2E
|
|
| Denmark, 2.5-meter |
BN19K-2E
|
|
| Egypt, India, South Africa, 2.5-meter |
BN19S-2E
|
|
| Italy, 2.5-meter |
BN19M-2E
|
|
| Israel, 1.9-meter |
3R-A6883-AA
|
|
| Japan, 2.5-meter, Dentori approved |
3X-BN46F-02
|
|
| Republic of China (103541-001) |
BN19H-2E
|
|
| Switzerland, 2.5-meter |
BN19E-2E
|
|
| UK, Ireland, 2.5-meter |
BN19A-2E
|
|
|
|
||
| Keyboard or Mouse Extension Cable | 6-foot/1.8-meter keyboard or mouse extension cable; to extend both keyboard and mouse order two cables |
3X-BC34A-06
|
|
|
||
| Video Extension Cable | 6-foot/1.8-meter video extension cable |
BN39C-02
|
|
|
||
| Step 11 - Graphics Support — Optional |
|
|
| Description | Device Type | Part Number | Maximum Quantity Tested & Supported | |||
| U=Tru64 UNIX O=OpenVMS L=Redhat V7.2 Linux |
||||||
| per system | per hard partition: per system | |||||
| ES47 Tower Workstation | ES47 | ES80 | GS1280 | |||
|
Graphics Adapters
|
||||||
|
ATI RADEON 7500 2D/3D AGP graphics accelerator
|
AGP 4X | 3X-PBXGG-AB |
1/U 1/O |
4:4/U 4:4/O |
4:8/U 4:8/O |
4:64/U 4:64/O |
|
ATI RADEON 7500 2D/3D PCI graphics accelerator
|
PCI 3.3V, 66MHz | 3X-PBXGG-AA | 4/U 4/O |
4:4/U 4:4/O |
4:8/U 4:8/O |
4:64/U 4:64/O |
|
For RADEON 7500 option information see:
PCI: http://h18002.www1.hp.com/alphaserver/options/ases47/ases47_3x-pbxgg-aa.html AGP: http://h18002.www1.hp.com/alphaserver/options/ases47/ases47_3x-pbxgg-ab.html Performance NOTE: The AGP version of the Radeon graphics accelerator will deliver significantly better performance for EV7 systems because the AGP bus is faster than the PCI bus; plus the AGP accelerator does not contend with other adapters on the AGP bus (each AGP bus has only one adapter slot). The Radeon AGP graphics accelerator delivers about the same performance on EV7 and EV68 systems. However, the Radeon PCI graphics accelerator delivers noticeably better performance on EV68 systems compared to EV7 systems because the EV7 systems' hardware implementation of "Programmable I/O" is not as fast as the EV68 implementation. |
||||||
| Graphics Software | Tru64 UNIX Open3D license for RADEON 7500 (required for 3D functionality) |
QL-6ZRA9-AA
|
| OpenVMS Open3D license for RADEON 7500 (required for 3D functionality for OpenVMS 7.3.x and earlier versions. Later versions of OpenVMS include the license for 3D functionality) |
QL-0ADA9-AA
|
|
| Additional Tru64 UNIX media kit for RADEON 7500 (initial kit ships with RADEON card) |
QA-6ZRAA-H8
|
|
|
|
||
| Tru64 UNIX |
Software Processor Codes in part numbers |
|
| Tru64 UNIX media and online documentation on CD-ROM |
QA-6ADAA-H8
|
|
| Tru64 UNIX full hard copy documentation |
QA-6ADAA-GZ
|
|
| TruCluster Plus Software Package with licenses for TruCluster Server, Logical Storage Manager and AdvFS Utilities |
QP-6R9Ax-AA
|
|
| TruCluster Server license |
QL-6BRAx-AA
|
|
| Logical Storage Manager license |
QL-2GVAx-AA
|
|
| AdvFS Utilities license |
QL-0EGAx-AA
|
|
| Advanced Server for Tru64 UNIX, 25 client concurrent use license |
QL-5U29M-3D
|
|
| Advanced Server for Tru64 UNIX, 50 client concurrent use license |
QL-5U29M-3E
|
|
| Advanced Server for Tru64 UNIX, 100 client concurrent use license |
QL-5U29M-3F
|
|
| Advanced Server for Tru64 UNIX, 250 client concurrent use license |
QL-5U29M-3G
|
|
| Advanced Server for Tru64 UNIX, 500 client concurrent use license |
QL-5U29M-3H
|
|
| Layered products media and documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8
|
|
| DECnet/OSI end-system function license for Tru64 UNIX |
QL-MTJAx-AA
|
|
| DECnet/OSI extended license for Tru64 UNIX |
QL-MTKAx-AA
|
|
|
|
||
| OpenVMS |
Software Processor Codes in part numbers |
|
| Concurrent Use 1-user license |
QL-MT3AA-3B
|
|
| Concurrent Use 2-user license |
QL-MT3AA-3C
|
|
| Concurrent Use 4-user license |
QL-MT3AA-3D
|
|
| Concurrent Use 8-user license |
QL-MT3AA-3E
|
|
| Concurrent Use 16-user license |
QL-MT3AA-3F
|
|
| Concurrent Use 32-user license |
QL-MT3AA-3G
|
|
| Concurrent Use 64-user license |
QL-MT3AA-3H
|
|
| Concurrent Use 128-user license |
QL-MT3AA-3J
|
|
| Concurrent Use 256-user license |
QL-MT3AA-3K
|
|
| Traditional unlimited-user license |
QL-MT2Ax-AA
|
|
| OpenVMS media and online documentation
on CD-ROM |
QA-MT1AA-H8
|
|
| OpenVMS hard copy documentation |
QA-001AA-GZ
|
|
| OpenVMS base hard copy documentation |
QA-09SAA-GZ
|
|
| OpenVMS Alpha Software Products
Library Package: Layered products media and documentation for OpenVMS on
CD-ROM, includes media and documentation for all products licensed in the
Enterprise Integration Package. |
QA-03XAA-H8
|
|
| DECnet-Plus/DECnet end-system
license |
QL-MTFAx-AA
|
|
| DECnet-Plus/DECnet extended-function
license |
QL-MTHAx-AA
|
|
| Cluster License for OpenVMS Alpha |
QL-MUZAx-AA
|
|
| OpenVMS Volume shadowing license |
QL-2A1Ax-AA
|
|
|
|
||
| OpenVMS Galaxy | |
| Galaxy Soft Partition Rules |
For more information about OpenVMS Galaxy requirements, configurations, and procedures, refer to the OpenVMS Alpha Galaxy Guide. The latest version is always available at http://h71000.www7.hp.com/availability/galaxy.html |
|
|
|
| Galaxy 1-CPU License |
QL-66XAA-3B
|
|
| Galaxy 2-CPU License |
QL-66XAA-3C
|
|
| Galaxy 4-CPU License |
QL-66XAA-3D
|
|
| Galaxy 8-CPU License |
QL-66XAA-3E
|
|
| Galaxy 16-CPU License |
QL-66XAA-3F
|
|
|
|
||
| Step 13 - Hardware and Software Support Services — Optional |
|
|
| HP Care Pack Services | HP Care Pack Services are available for AlphaServer systems running Tru64 UNIX or OpenVMS operating systems. HP Care Pack Services are designed for customers who need support beyond that provided by the hardware product warranty with coverage for both Principal Server systems and SSPs (Subsequent System Packages) - that meet a full range of customer support requirements. |
|
|
|
| System Codes for Service Part Numbers |
ES47 Tower and Workstation
|
x = F, yy = GA, aaa = 6JM, bbb = 5LA
|
|
ES47 Model 2 and Model 4
|
x = F, yy = GB, aaa = 6JN, bbb = 5LB
|
|
|
ES80 Model 2 and Model 4
|
x = F, yy = HA, aaa = 6JP, bbb = 5LB
|
|
|
ES80 Model 6 and Model 8
|
x = F, yy = HB, aaa = 6JQ, bbb = 5LC
|
|
|
GS1280 Model 8
|
x = W, yy = BA, aaa = 6JR, bbb = 5LG
|
|
|
GS1280 Model 16
|
x = W, yy = BB, aaa = 6JS, bbb = 5LG
|
|
|
GS1280 Model 32
|
x = W, yy = BD, aaa = 6JT, bbb = 5LH
|
|
|
GS1280 Model 64
|
x = W, yy = BE, aaa = 6JU, bbb = 5LH
|
|
|
|
||
| Program Features - Principal Server | |||
| HP Support Plus |
|
||
| HP Support Plus, Principal Server,
12 months |
HA109A1-aaa
|
FP-x01yy-12
|
|
| HP Support Plus, Principal Server,
36 months |
HA109A3-aaa
|
FP-x01yy-36
|
|
|
|
|||
| HP Support Plus 24 |
|
||
| HP Support Plus 24, Principal
Server, 12 months |
HA110A1-aaa
|
FP-x02yy-12
|
|
| HP Support Plus 24, Principal Server, 36 months |
HA110A3-aaa
|
FP-x02yy-36
|
|
|
|
|||
| HP Proactive 24 |
|
|
| HP Proactive 24, 12 months |
HA111A1-aaa
|
|
| HP Proactive 24, 36 months |
HA111A3-aaa
|
|
|
|
||
| Critical Services |
|
|
| Critical Services, 12 months |
HA112A1-aaa
|
|
| Critical Services, 36 months |
HA112A3-aaa
|
|
|
|
||
| Program Features - Additional Services | ||
| SSPs (Subsequent System Packages) |
|
|
| HP Support Plus, Subsequent System,
12 months |
FP-x21yy-12
|
|
| HP Support Plus, Subsequent System, 36 months |
FP-x21yy-36
|
|
| HP Support Plus 24, Subsequent System, 12 months |
FP-x22yy-12
|
|
| HP Support Plus 24, Subsequent System, 36 months |
FP-x22yy-36
|
|
|
|
||
| Installation |
|
||
| Installation |
HA113A1-bbb
|
FP-xINST-yy
|
|
|
|
|||
| Installation and Startup HP O/S |
|
||
| Installation and Startup |
HA114A1-bbb
|
FP-xSTAR-yy
|
|
|
|
|||
NOTES:
|
|
|
| Recommended Factory Integration Services | Value-added Implementation Services (VIS) provides systems integration and delivery services. VIS services, including system integration, extended burn-in, custom documentation, and on-site services can be custom-quoted for the full range of AlphaServer configurations. These pre-packaged services are offered for systems shipped to North America and Japan. For similar services in Europe, e-mail specific requirements to: customsystems.europe@hp.com For similar services in Asia/Pacific, e-mail specific requirements to: customsystems.asiapacific@hp.com |
|
Pre-packaged VIS services are recommended for system configurations that
include up to one storage array:
|
|
|
|
|
| Basic Integration Service | Systems integration and delivery services related to the configuration of the first and/or only instance of an operating system on a single AlphaServer. Includes the following: |
YT-VISIT-B1
|
|
||
|
|
||
| Extra RAID Pair Service | Configuration of additional Intelligent RAID controller pairs beyond the internal and external RAID controller pairs included within the scope of the prerequisite YT-VISIT-B1 on the same single AlphaServer platform. The following services are included in the optional YT-VISIT-R1 Extra RAID Pair Service per each additional pair of Intelligent RAID controllers configured: |
YT-VISIT-R1
|
|
||
|
|
||
| Clustering Service | Configuration of a single cluster instance for AlphaServer platforms. This is a per-cluster service and is ordered along with the prerequisite YT-VISIT-B1 services. |
YT-VISIT-C1
|
|
||
|
|
||
| Partitioning Service | Configuration of multiple, non-clustered instances of a second or subsequent operating system on a single AlphaServer platform. This is a per-partition service and is ordered along with the prerequisite YT-VISIT-B1 services. The first instance of an operating system is included in the YT-VISIT-B1 service, subsequent partitions require the YT-VISIT-P1 partitioning service. |
YT-VISIT-P1
|
|
||
|
|
||
| Full Custom Configurations | The Integration Service Packages address the most-common customer requirements. For a wider range of configurations, customers can also choose additional customized services based upon a Statement of Work agreement. This includes: cluster add-on nodes, larger storage configurations, custom option support, custom system packaging, mixed operating system partitions, and configured multi-system clusters. Contact your local sales representative for these services. |
|
|
Upgrades
|
ES80 Model 8 |
||||
| ES80 Model 6 to ES80 Model 8 Upgrade Kit 3X-BA60B-AD |
||||
| ES80 Model 6 | ||||
| ES80 Model 4 to ES80 Model 6 Upgrade Kit 3X-BA60B-AC |
||||
| ES47 Model 4 | ES47 to ES80 Conversion Kit 3X-BA60B-A* HP layered software for the ES47 must be upgraded from the Workgroup tier to a Departmental tier licenses for the ES80. |
ES80 Model 4 | ||
| ES47 Model 2 to ES47 Model 4 Upgrade Kit 3X-BA60B-AH |
ES80 Model 2 to ES80 Model 4 Upgrade Kit 3X-BA60B-AB |
|||
| ES47 Model 2 | ES47 to ES80 Conversion Kit 3X-BA60B-A* HP layered software for the ES47 must be upgraded from the Workgroup tier to a Departmental tier licenses for the ES80. |
ES80 Model 2 | ||
| AlphaServer ES47 Tower
to AlphaServer ES47 Model 2 Upgrade Kits 3X-BA60B-AA & 3X-BA60B-AF |
||||
| ES47 Tower | ||||
|
|
||||
|
|
||
|
|
||
| NOTE:
All Upgrade Kits for ES47/80 include slide kits for mounting the H9A40/H9A45
racks. To mount the Upgrade kits in the 10000 Series Racks, order (in addition
to the Upgrade Kit): ES47/ES80 Slide Kit for mounting in 10000 Series Racks. |
CK-BA60B-AA
|
|
|
AlphaServer ES47 Tower to AlphaServer ES47 Model 2 Upgrade Kits |
System expansion hardware and software to upgrade a Tru64 UNIX AlphaServer ES47 Tower to an AlphaServer ES47 Model 2. Includes one rackmount slide kit and one Tru64 UNIX SMP License. |
3X-BA60B-AA
|
| System expansion hardware and software to upgrade an OpenVMS AlphaServer ES47 Tower to an AlphaServer ES47 Model 2. Includes one rackmount slide kit and one OpenVMS SMP License. |
3X-BA60B-AF
|
|
|
|
||
| ES47 Model 2 to Model 4 Upgrade Kit | System expansion hardware to upgrade an AlphaServer ES47 Model 2 to an AlphaServer ES47 Model 4. Includes one System Building Block Drawer with two power supplies; one rackmount slide kit; associated inter-processor cabling. (CPU Building Block Module and memory options are required. See Steps 3 and 4.) |
3X-BA60B-AH
|
|
|
||
| ES47 to ES80 Trade Up Kits | ES80 Base Operating System license for Tru64 UNIX to convert an AlphaServer ES47 to an AlphaServer ES80; hardware jumpers to identify system as an ES80; and ES80 identifying bezel |
3X-BA60B-AU
|
| ES80 Base Operating System license for OpenVMS to convert an AlphaServer ES47 to an AlphaServer ES80; hardware jumpers to identify system as an ES80; and ES80 identifying bezel |
3X-BA60B-AV
|
|
|
NOTES:
|
||
|
|
||
| ES80 Model 2 to Model 4 Upgrade Kit | System expansion hardware to upgrade an AlphaServer ES80 Model 2 to an AlphaServer ES80 Model 4. Includes one System Building Block Drawer with two power supplies; one rackmount slide kit; associated inter-processor cabling. (CPU Building Block Module and memory options are required. See Steps 3 and 4.) |
3X-BA60B-AB
|
|
|
||
| ES80 Model 4 to Model 6 Upgrade Kit | System expansion hardware to upgrade an AlphaServer ES80 Model 4 to an AlphaServer ES80 Model 6. Includes one System Building Block Drawer with two power supplies; one rackmount slide kit; associated inter-processor cabling. (CPU Building Block Module and memory options are required. See Steps 3 and 4.) |
3X-BA60B-AC
|
|
|
||
| ES80 Model 6 to Model 8 Upgrade Kit | System expansion hardware to upgrade an AlphaServer ES80 Model 6 to an AlphaServer ES80 Model 8. Includes one System Building Block Drawer with two power supplies; one rackmount slide kit; associated inter-processor cabling. (CPU Building Block Module and memory options are required. See Steps 3 and 4.) |
3X-BA60B-AD
|
|
|
Technical Specifications
| AlphaServer ES47 Tower System | |||
| Power Requirements | US/Canada | Japan | International |
| Nominal voltage(s) | 100-120/200-240V * | 100-120/200-240V | 100-120/200-240V |
| Phase/Frequency | Single Phase/50-60 Hz | Single Phase/50-60 Hz | Single Phase/50-60 Hz |
| Rating | 10/7A per cord | 10/7A per cord | 10/7A per cord |
| Power Plug | IEC 320 C13 to Country Specific | IEC 320 C13 to Country Specific | IEC 320 C13 to Country Specific |
| * NOTE: 100-120V operation requires that two power supplies be present; power supply redundancy is not provided during 100-120V operation | |||
| Physical Characteristics | |||
| Dimensions (H x W x D) | 20.1 x 8.6 x 35 in (51 x 22 x
90 cm) |
||
| Shipping dimensions | 48 x 30 x 18.5 in (122 x 76 x 47 cm) | ||
| Weight Maximum Configuration | 132 lb (59 kg) | ||
| Shipping Weight - Maximum Configuration - cardboard outside wrap not included | 164 lb (73 kg) | ||
| Heat dissipation | Minimally configured system | 783W / 2672 Btu/hr | |
| Fully configured system | 850W / 2701 Btu/hr | ||
| Clearances | Operating | Service | |
| Front | 6 in (15 cm) | 6 in (15 cm) | |
| Rear |
6 in (15 cm) | 6 in (15 cm) | |
| Left Side |
None | None | |
| Right Side | None | 29.5 in (75 cm) | |
| Environmental | |||
| Temperature | 50 to 104° F (10 to 40° C) | -40 to 151° F (-40 to 66° C) | |
| Humidity | 10% to 90% | 10% to 95%, Storage (60 days) 115° F/46° C | |
| Altitude | 10,000 ft (3,050 m) | 40,000 ft (12,200 m) | |
| NOTE: Maximum operating temperature at sea level; reduce by 1.8° F (1° C) for each 2,000 ft (600 m) above sea level | |||
| Vibration | 10 to 500 Hz 0.1G peak | 1.03 Grms 5-300 Hz | |
| Shock | 5G 30ms, half sine | ||
| Acoustics (Declared values per ISO 9296 and ISO 7779) | |||
| Idle/Operating | (Bystander pos.) | ||
| Description | LwAd, B | LpAm, dBA | |
| ES47 Tower | 6.6 | 47 | |
| Regulatory | |||
| Agency approvals | UL: Listed to UL 60950;
cUL: Listed to CAN/CSA-C22.2 No.950 3rd Ed, 1995 CB Report to IEC 950:1991+A1: 1992 + A2: 1993 + A3: 1995 + A4:1996 CB Report to EN60950 (1992) with Amdts. 1, 2, 3, 4 and 11 FCC: Part 15.B Class A IC ICES-003 Class A CE: EN55022: 1998, EN55024: 1998, EN61000-3-2: 1995, EN61000-3-3: 1995 VCCI: V-3/02.04 Class A BSMI: CNS 13438 Class A C-Tick:AS/NZS 3548:1995 Class A |
||
|
|
|||
| AlphaServer ES47/ES80 Rack Systems | |||
| Power Requirements | North America | Japan | International |
| PDU Part Number | 3X-H7606-AA | 3X-H7606-AA | 3X-H7606-AB |
| Nominal voltage(s) | 208 | 200 | 380/415 |
| Phase/Frequency | 3W+G, 50-60 Hz | 3W+G, 50-60 Hz | 3W+N+G, 50-60 Hz |
| Rated Current | 24A | 24A | 24A |
| Line Connection | Fixed cord & plug | Fixed cord & plug | Fixed cord & plug |
| Power Cord | 5 x 10AWG | 5 x 10AWG | 5 x 4 mm2 |
| Power Plug | L21-30P, Hubbell 2811 | L21-30P, Hubbell 2811 | IEC 32A, Hubbell 532P6W |
| Main Breaker | 30A | 30A | 30A |
| Sub-breakers | 3 x 20A(2p), 1 x 20A(3p) | 3 x 20A(2p), 1 x 20A(3p) | 3 x 15A(2p), 1 x 15A(3p) |
| Agency | UL Listed, cUL | UL Listed, cUL | TUV & CB report |
| PDU Part Number | 3X-H7609-EB | 3X-H7609-EB | 3X-H7609-DB |
| Nominal voltage(s) | 200-240 | 200-240 | 240 |
| Phase/Frequency | Single Phase/50-60 Hz | Single Phase/50-60 Hz | Single Phase/50-60 Hz |
| Phases | Single Phase | Single Phase | Single Phase |
| Power Plug | NEMA L6-20P | NEMA L6-20P | IEC309 type 2P+G |
| ES47/ES80 Model 2 |
ES47/ES80 Model 4 |
ES80 Model 6 1 I/O Expansion Drawer |
ES80 Model 8 2 I/O Expansion Drawers |
|
| Power Required, Kva | 0.925 | 1.85 | 3.775 | 5.7 |
| Physical Characteristics | ||||
| Dimensions (H x W x D) | 79 x 24 x 47 in (200
x 60 120 cm) (41U Rack) 6 x 17.5 x 34 in (15 x 44.5 x 86 cm) (Drawer) |
|||
| Shipping dimensions | 86 x 32 x 48 in (217 x 92.5 142 cm) (41U Rack) | |||
| ES47/ES80 Model 2 1 I/O Expansion Drawer, 1 StorageWorks Shelf, 41U Rack |
ES47/ES80 Model 4 2 I/O Expansion Drawers, 1 StorageWorks Shelf, 41U Rack |
ES80 Model 6 3 I/O Expansion Drawers, 1 StorageWorks Shelf, 41U Rack |
ES80 Model 8 4 I/O Expansion Drawers, 1 StorageWorks Shelf, 41U Rack |
|
| Weight Maximum Configuration | 706 lb (320 kg) |
910 lb (412 kg) |
1104 lb (500 kg) |
1304 lb (591 kg) |
| Shipping Weight - Maximum Configuration - cardboard outside wrap not included | 883 lb (400 kg) | 1088 lb (493 kg) | 1282 lb (581 kg) | 1483 lb (672 kg) |
| Heat dissipation | ||||
| Minimally configured system; 1 PCI option, 1 disk, and 8 memory RDRAM RIMMs per 2P Building Block Drawer. | 894 W | 1788 W | 2682 W | 3576 W |
| Btu/hr |
3051 |
6102 |
9153 |
12204 |
| Airflow@20C DT, cfm | 227 | 554 | 831 | 1108 |
| Fully configured system; 3 PCI, 1 AGP, 2 disks, and 20 RDRAM RIMMs per 2P Building Block Drawer) | 1930 W | 3860 W | 4596 W | 5928 W |
| Btu/hr |
6587 |
13174 | 15686 | 20230 |
| Airflow@20C DT, cfm | 492 | 984 | 1476 | 1968 |
|
|
||||
| Clearances - All Models | Operating | Service |
| Front | 32 in (81 cm) | 32 in (81 cm) |
| Rear |
44 in (111 cm) |
44 in (111 cm) |
| Left Side | None | None |
| Right Side |
None |
None |
| Environmental | Operating | Non-Operating |
| Temperature | 50° to 104° F (10°
to 40° C) |
-40° to 151° F (-40°
to 66° C) |
| Humidity | 10% to 90% | 10% to 95%, Storage (60 days) 115° F (16° C) |
| Altitude | 10,000 ft (3,050 m) NOTE: Maximum operating temperature at sea level; reduce by 1.8° F (1° C) for each 2,000 ft (600 m) above sea level |
40,000 ft (12,200 m) |
| Vibration |
10 to 500 Hz 0.1G peak |
1.03 Grms 5-300 Hz |
| Shock | 5G 30ms, half sine |
| Acoustics (Declared values per ISO 9296 and ISO 7779) | ||||||
| Standard I/O Expansion or Master
Drawer 3X-BA70A-BA |
4300 Series StorageWorks Shelf DS-SL13R-xx |
ES47/ES80 Model 2 # I/O Drawers |
ES47/ES80 Model 4 # I/O Drawers |
ES80 Model 6 # I/O Drawers |
ES80 Model 8 # I/O Drawers |
|
| Idle/Operating, LwAd, B |
7.1 |
6.9 |
6.6 |
6.9 |
7.1 |
7.2 |
| Bystander pos., LpAm, dBA | 51 | 53 | 48 | 51 | 53 | 54 |
| Regulatory - Agency approvals | UL: Listed to UL 60950; cUL: Listed
to CAN/CSA-C22.2 No.6950-00 CB Report to IEC 950:1991+A1: 1992 + A2:1993 + A3: 1995 + A4:1996 CB Report to EN60950 (1992) with Amdts. 1, 2, 3, 4 and 11 FCC: Part 15.B Class A IC ICES-003 Class A CE: EN55022: 1998, EN55024: 1998, EN61000-3-2: 1995, EN61000-3-3: 1995 VCCI: V-3/02.04 Class A BSMI: CNS 13438 Class A C-Tick:AS/NZS 3548:1995 Class A |
|||||
|
|
||||||
| © Copyright 2007 Hewlett-Packard
Development Company, L.P. The information contained herein is subject to change without notice. UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |