Overview
|
HP 64-bit/133-MHz Single Channel Ultra320 SCSI G2 host bus adapter |
|
| The HP 64-bit/133-MHz Single Channel Ultra320 SCSI host bus adapter (HBA) provides customers with the flexibility and speed they have come to expect from HP. The 64-bit/133-MHz Single Channel Ultra320 SCSI HBA is ideal for HP tape products and larger non-RAID storage applications. This adapter supports Ultra320 SCSI, Wide Ultra3 SCSI, and Wide Ultra2 SCSI protocols. It is the primary building block for non-RAID SCSI storage solutions that provide the maximum of 320 MB/second bandwidth, twice the speed of our current SCSI adapters. HP's 64-bit/133-MHz Single Channel Ultra320 SCSI HBA has two primary uses: 1) tape backup and 2) JBOD file and print applications. Neither application requires fault tolerance but both have large bandwidth requirements. | |
| Models | |
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
|
|
Standard Features
| Performance | |
| The HP 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA provides support for up to 14 SCSI devices, while only taking up a single PCI-X slot. The HP 64-Bit/133-MHz Single Channel Ultra320 SCSI adapter delivers exceptional system performance, along with one Ultra320 SCSI channel that provides up to 64-bit/133-MHz bus-master capabilities, transferring data up to 320 MB/s between storage subsystem and system memory. | |
| HP Integration | Fully integrated and tested with HP ProLiant 100 series servers, ProLiant 300 series servers, ProLiant 500 series servers, and all HP StorageWorks SCSI tape products. |
| Tagged Command Queuing | Improves performance by accepting commands simultaneously, sorting efficiently and minimizing response time. |
| Suggested Solutions | HP's 64-Bit/133-MHz Single Channel Ultra320 adapter is a cost effective solution NHP SCSI HDD and ideal for DAT tape drives on ProLiant 100 series servers |
|
|
|
| Fault Tolerance |
| Supports software-based fault tolerant configurations available under:
NOTE: For more Linux OS support & certification information, please visit our the ProLiant & BladeSystem Server Linux matrix: http://h18004.www1.hp.com/products/servers/linux/hplinuxcert.html |
| |
| Compatibility |
|
Fully integrated and tested with selected HP ProLiant servers and HP tape drives.
NOTE: This is a list of supported servers. Some may be discontinued. |
| |
| Option Kit Contents |
|
| |
| Warranty |
| Maximum: The remaining warranty of the HP product in which it is installed (to a maximum one-year limited warranty, parts only) |
| Minimum: One-year, on-site limited warranty, parts only |
| NOTE: Certain restrictions and exclusions apply. Consult the Customer Support Center at 1-800-345-1518 for details. |
|
|
Related Options
| NOTE: This is a list of supported options - some may be discontinued. | ||
| Hard Drives | NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and
the server backplane) should operate at the same data transfer rate or the
system bandwidth will be negotiated down to an acceptable level for all
components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|
| 10,000 RPM Universal Hard Drive | ||
| HP 300GB U320 10K Universal HDD | 350964-B22 | |
| HP 146GB U320 10K Universal HDD | 286716-B22 | |
| HP 72GB U320 10K Universal HDD | 286714-B22 | |
| 15,000 RPM Universal Hard Drive | ||
| HP 300GB U320 15K Universal HDD | 411089-B22 | |
| HP 146GB U320 15K Universal HDD | 347708-B22 | |
| HP 72GB U320 15K Universal HDD | 286778-B22 | |
| HP 36GB U320 15K Universal HDD | 286776-B22 | |
| NOTE: For complete compatibility information, refer to the HP SCSI Hard Drive Compatibility table located at: http://www.hp.com/servers/hdd-documentation. | ||
|
|
||
| Tape Drives | NOTE: For the
complete listing of Tape Drive offerings, please see: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html |
|
| DAT Tape Drives | ||
| HP StorageWorks DAT 40 SCSI Internal Tape Drive (Carbon) |
C5686C
|
|
| HP StorageWorks DAT 40 SCSI External Tape Drive (Carbon) |
C5687D
|
|
| HP StorageWorks DAT 40 SCSI Array Module (Carbon) |
C7497C
|
|
| HP StorageWorks DAT 72 SCSI Internal Tape Drive (Carbon) |
Q1522B
|
|
| HP StorageWorks DAT 72 SCSI External Tape Drive (Carbon) |
Q1523B
|
|
| HP StorageWorks DAT 72 SCSI Array Module (Carbon) |
Q1524C
|
|
| HP StorageWorks DAT 160 SCSI Internal Tape Drive |
Q1573A
|
|
| HP StorageWorks DAT 160 SCSI External Tape Drive |
Q1574A
|
|
| HP StorageWorks DAT 160 SCSI Array Module |
Q1575A
|
|
| Ultrium Tape Drives | ||
| HP StorageWorks LTO-1 Ultrium 232 Internal Tape Drive (Carbonite) |
DW064A
|
|
| HP StorageWorks LTO-1 Ultrium 232 External Tape Drive (Carbonite) |
DW065B
|
|
| HP StorageWorks LTO-2 Ultrium 448 SCSI Internal Tape Drive (Carbonite) |
DW016A
|
|
| HP StorageWorks LTO-2 Ultrium 448 SCSI External Tape Drive (Carbonite) |
DW017B
|
|
| HP StorageWorks LTO-2 Ultrium 448 SCSI Array Module (Carbonite) |
DW019A
|
|
| HP StorageWorks 1U SCSI Rack-mount kit with one LTO-2 Ultrium 448 SCSI Tape Drive (Carbonite) |
DW028B
|
|
| HP StorageWorks LTO-3 Ultrium 920 SCSI Internal Tape Drive |
EH841A
|
|
| HP StorageWorks LTO-3 Ultrium 920 SCSI External Tape Drive |
EH842A
|
|
| HP StorageWorks 1U SCSI Rack-mount kit with one LTO-3 Ultrium 920 |
EH903A
|
|
| HP StorageWorks LTO-3 Ultrium 960 Internal Tape Drive (Carbonite) |
Q1538A
|
|
| HP StorageWorks LTO-3 Ultrium 960 External Tape Drive (Carbonite) |
Q1539B
|
|
| HP StorageWorks LTO-3 Ultrium 960 Array Module (Carbonite) |
Q1540A
|
|
| HP StorageWorks 3U SCSI Rack-mount kit with one LTO-3 Ultrium 960 (Carbonite) |
Q1595B
|
|
| HP StorageWorks LTO-4 Ultrium 1840 SCSI Internal Tape Drive | EH853A | |
| HP StorageWorks LTO-4 Ultrium 1840 SCSI External Tape Drive | EH854A | |
| HP StorageWorks LTO-4 Ultrium 1840 SCSI Array Module | EH856A | |
| HP StorageWorks 3U SCSI Rack-Mount with 1 LTO-4 Ultrium 1840 Tape Drive | EH926A | |
| DLT VS/SDLT Tape Drives | ||
| HP StorageWorks DLT VS160 Internal Tape Drive (Carbon) |
A7569B
|
|
| HP StorageWorks DLT VS160 External Tape Drive, North America (Carbon) |
A7570B
|
|
| HP StorageWorks DLT VS160 External Tape Drive, International (Carbon) |
A7571B
|
|
| HP StorageWorks SDLT 600 Internal Tape Drive (Carbon) |
A7518B
|
|
| HP StorageWorks SDLT 600 External Tape Drive, North America (Carbon) |
A7519B
|
|
| HP StorageWorks SDLT 600 External Tape Drive, Worldwide (Carbon) |
A7520B
|
|
| Rack-Mount Tape Drive Enclosures | ||
| HP StorageWorks 1U SCSI Rack-Mount
kit NOTE: The 1U Rack-Mount Kit can support up to (2) half-height tape drives and is compatible with multiple Single-Ended and LVD SCSI tape drives including the DAT 40, DAT 72, DAT 160, DLT VS160, LTO-1 Ultrium 232, LTO-2 Ultrium 448 and LTO-3 Ultrium 920 tape drives. |
A7445B
|
|
| HP StorageWorks 3U Rack-mount
kit NOTE: The 3U Rack-mount Kit can support up to (2) full-height or (4) half-height tape drives and compatible with multiple LVD SCSI tape drives including DAT 40, DAT 72, DAT 160, DLT VS160, SDLT 600, LTO-1 Ultrium 232, LTO-2 Ultrium 460, LTO-2 Ultrium 448, LTO-3 Ultrium 920, LTO-3 Ultrium 960 and LTO-4 Ultrium 1840 tape drives. |
274338-B22 | |
|
|
||
| Tape Autoloaders | HP StorageWorks DAT Autoloader | |
| HP StorageWorks DAT 72x10 tape autoloader | AE313B | |
| HP StorageWorks 1/8 Tape Autoloader | ||
| HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 Tape Autoloader | AH165A | |
| HP StorageWorks 1/8 G2 LTO-2 Ultrium 448 Tape Autoloader | AH164A | |
| HP StorageWorks 1/8 G2 LTO-1 Ultrium 232 Tape Autoloader | AH163A | |
| NOTE: Please reference the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs | ||
| | ||
| Tape Libraries | HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ033A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 960 SCSI Drive Library | AG115A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SCSI Drive Library | AH169A | |
| HP StorageWorks MSL2024 2 LTO-3 Ultrium 920 SCSI Drive Library | AH170A | |
| HP StorageWorks MSL2024 1 LTO-2 Ultrium 448 SCSI Drive Library | AG116A | |
| HP StorageWorks MSL2024 2 LTO-2 Ultrium 448 SCSI Drive Library | AG117A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ035A | |
| HP StorageWorks MSL4048 2 LTO-4 Ultrium 1840 SCSI Drive Library | AJ037A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 960 SCSI Drive Library | AG322A | |
| HP StorageWorks MSL4048 2 LTO-3 Ultrium 960 SCSI Drive Library | AG323A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SCSI Drive Library | AH171A | |
| HP StorageWorks MSL4048 2 LTO-3 Ultrium 920 SCSI Drive Library | AH172A | |
| HP StorageWorks MSL4048 1 LTO-2 Ultrium 448 SCSI Drive Library | AG320A | |
| HP StorageWorks MSL4048 2 LTO-2 Ultrium 448 SCSI Drive Library | AG321A | |
| HP StorageWorks MSL8096 Tape Library | ||
| HP StorageWorks MSL8096 2 LTO-4 Ultrium 1840 SCSI Drive Library | AJ039A | |
| HP StorageWorks MSL8096 2 LTO-3 Ultrium 960 SCSI Drive Library | AH219A | |
| HP StorageWorks MSL6000 Tape Library | ||
| LTO-3 Ultrium 960 technology | ||
| HP StorageWorks MSL6030 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ029A | |
| HP StorageWorks MSL6030 1 LTO-3 Ultrium 960 SCSI Drive Library | AD606B | |
| HP StorageWorks MSL6030 2 LTO-3 Ultrium 960 SCSI Drive Library | AD607B | |
| HP StorageWorks MSL6060 2 LTO-4 Ultrium 1840 SCSI Drive Library | AJ031A | |
| HP StorageWorks MSL6060 2 LTO-3 Ultrium 960 SCSI Drive Library | AD610B | |
| | ||
| Internal Cables | LVD cable (U320) | 166389-B21 |
|
|
Technical Specifications
| SCSI Protocols | Ultra320 Wide Ultra3 SCSI (Ultra160) Wide Ultra2 SCSI Ultra SCSI |
| Electrical Protocol | Low Voltage Differential (LVD) |
| SCSI Devices Supported | Up to 14 |
| Storage Capacity | Up to 1.8 TB (6 x 300GB) |
| Data Transfer Method | 64-bit/133-MHz PCI-X bus-master |
| Maximum SCSI Transfer Rate | 320 MB/s |
| Operating System Support | Microsoft
Windows Server 2008 |
| NOTE: For more Linux OS support & certification information, please visit our the ProLiant & BladeSystem Server Linux matrix: http://h18004.www1.hp.com/products/servers/linux/hplinuxcert.html | |
| External SCSI Connectors | One 68-Pin VHDCI connectors (Only on the G2 HBA) |
| Internal SCSI Connectors | One SCSI-3 (68-Pin) |
|
| |
| Environment-friendly Products and Approach | End-of-life Management and Recycling | Hewlett-Packard offers end-of-life
HP product return, trade-in, and recycling programs in many geographic areas.
For trade-in information, please go to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will be recycled,
recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
| | ||
|
© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |