|
|
Overview
|
HP StorageWorks 1500 cs Modular Smart Array |
|
The HP StorageWorks 1500 cs Modular Smart Array is a 2Gb Fibre Channel
SAN attached 2U controller shelf that connects to both enterprise-class
SCSI and Serial ATA (SATA) disk enclosures. HP recommends SCSI drives
for intensive heavy I/O requirements while SATA drives should only be
used in archived, reference, or "near on-line" disk-to-disk
backup configurations. This combination provides customers with a low
cost, high capacity storage solution. The MSA1500 cs provides 2 Gb Fibre Channel to the hosts. By utilizing existing SCSI drive enclosures and MSA1000/1500 controller technology and integrating the use of our lowest cost SATA hard drives and enclosures, the MSA1500 cs lowers the total cost of ownership and extends the customers hardware investments into the future. With lower cost of ownership, customers can now take advantage of tiered storage capabilities matching up data with appropriate levels of performance, availability and cost of data storage. The result is lower overall cost without giving up the needs of business applications. The MSA1500 cs is a member of the HP StorageWorks Modular Smart Array family, delivering industry-leading technology to meet today's demanding and growing storage needs. These storage solutions offer the best price performance features for direct attach environments and entry-level and mid-range SAN environments. Each solution is designed to maximize transfer rates, reduce management costs, while driving rapid return on investment. The MSA1500 cs can be remotely managed by using management tools such as HP Insight Manager, Array Configuration Utility and the HP StorageWorks Fabric Switch Management Utility depending on the host's operating system. *Maximum available storage capacity depends on the RAID level being implemented, and is based on maximum number of LUNs (32) and maximum LUN size (2 TB). |
![]() |
|
|
| What's New |
|
| |
| Models | ||
| HP StorageWorks
1500 cs Modular Smart Array |
MSA1500 cs 2U Fibre Channel SAN Attach Controller Shelf
|
AA986A
|
| MSA1500 2U Fibre Channel SAN Attach
Controller Shelf, with one MSA20 SATA drive enclosure NOTE: For Americas, Asia Pacific, and Japan. |
AD509A | |
| Smart Buy Bundle | MSA1500 cs Controller Shelf and
MSA20 Enclosure w/ 12ea. 500 GB SATA HDDs. NOTE: Available in Americas only. |
AJ685A *NEW* |
| Smart Buy Bundle | MSA1500 cs Controller Shelf and
MSA20 Enclosure w/ 12ea. 750 GB SATA HDDs. NOTE: Available in Americas only. |
AJ686A *NEW* |
| MSA1500 2U Fibre Channel SAN Attach
Controller Shelf, with one MSA30 SCSI drive enclosure NOTE: For Americas, Asia Pacific, and Japan. |
AD510A | |
|
Smart Buy Bundle |
MSA1500 cs Controller Shelf and
MSA30 Enclosure w/ 14ea. 300 GB 10K SCSI HDDs. NOTE: Available in Americas only. |
AJ689A *NEW* |
| MSA1500 SAN SCSI G2 Starter Kit (w/ PCI-E HBAs) (Windows, Linux or NetWare compatible) NOTE: Includes (1) MSA1500 (1) MSA30 SB SCSI drive enclosure (1) 4/8 Base SAN Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables. |
AE327B | |
| MSA1500 SAN SATA Starter G2 Kit
(w/ PCI-E HBAs) (Windows, Linux or NetWare compatible) NOTE: Includes (1) MSA1500 (1) MSA20 SATA drive enclosure (1) 4/8 Base SAN Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables. NOTE: For Americas, Asia Pacific, and Japan only. |
AE326B | |
| MSA1500 SAN Starter Kit HA G2
Bundle (w/ PCI-E HBAs) for both SCSI and SATA SAN Starter G2 Kits (Windows, Linux, or NetWare compatible) NOTE: Includes (1) redundant controller; (1) FC I/O module; (1) 4/8 Base SAN Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables. User will need to employ either Secure Path (active/passive configurations), QLogic or Emulex failover, or Windows MPIO for path failover implementation. |
AE328B | |
| MSA1500 HP-UX Dual Controller
SCSI SAN Starter Kit NOTE: Includes (2) controllers; (1) MSA30 SB SCSI drive enclosure; (1) FC I/O module; (2) C-Series 9124 SAN Switches; (8) 4Gb SFP transceivers; (4) HP PCI-X 2.0 1Port 4Gb HBAs + cables. User will employ PVlinks for path failover implementation. |
AG704A *NEW* |
|
| MSA1500 HP-UX Dual Controller
SATA SAN Starter Kit NOTE: Includes (2) controllers; (1) MSA20 SATA drive enclosure; (1) FC I/O module; (2) C-Series 9124 SAN Switches; (8) 4Gb SFP transceivers; (4) HP PCI-X 2.0 1Port 4Gb HBAs + cables. User will employ PVlinks for path failover implementation. NOTE: For Americas, Asia Pacific, and Japan only. |
AG705A *NEW* |
|
| MSA1500 HP-UX SCSI SAN Starter
Kit (Single Controller) NOTE: Includes (1) controller; (1) MSA30 SB SCSI drive enclosure; (1) C-Series 9124 SAN Switch; (4) 4Gb SFP transceivers; (2) HP PCI-X 2.0 1Port 4Gb HBAs + cables. NOTE: For Americas, Asia Pacific, and Japan only. |
AG706A *NEW* |
|
| MSA1500 HP-UX SATA SAN Starter
Kit (Single Controller) NOTE: Includes (1) controller; (1) MSA20 SATA drive enclosure; (1) C-Series 9124 SAN Switch; (4) 4Gb SFP transceivers; (2) HP PCI-X 2.0 1Port 4Gb HBAs + cables. NOTE: For Americas, Asia Pacific, and Japan only. |
AG707A *NEW* |
|
| MSA1500 HP-UX High Availability
Kit (only for single controller kits) NOTE: Includes (1) redundant controller; (1) FC I/O module; (1) C-Series 9124 SAN Switch; (4) 4Gb SFP transceivers; (2) HP PCI-X 2.0 1Port 4Gb HBAs + cables. User will employ PVlinks for path failover implementation. NOTE: For Americas, Asia Pacific, and Japan only. |
AG708A *NEW* |
|
|
|
||
| Key Features |
|
| |
| Customer Benefits |
|
|
|
Family Comparison
|
MSA1500 cs |
MSA1000 |
MSA500 | |
|
NOTE: *SOME FEATURES AND FUNCTIONALITIES ARE OPERATING SYSTEM DEPENDENT | |||
| Capacity
(Maximum) |
16.8 TB SCSI/64 TB SATA
| 12.6
TB SCSI | 4.2
TB SCSI |
|
SCSI Interface |
Ultra 3, Ultra 320 |
Ultra 2, Ultra 3, Ultra 320 |
Ultra 2, Ultra 3, Ultra 320 |
| 2nd controller option | Active/Passive
or Active/Active* | Active/Passive | Active/Passive
|
|
Controller Cache |
256 MB standard
upgradeable to 512 MB |
256 MB standard
upgradeable to 512 MB |
256 MB standard
upgradeable to 512 MB |
|
Direct or SAN |
Direct or SAN Attach - Fibre* |
Direct or SAN Attach - Fibre |
Direct Attach - SCSI |
|
Maximum Drives |
56 SCSI, 96 SATA or mixed |
42 SCSI |
14 SCSI |
|
MTBF (drives) |
1.5M w/ SCSI @ 100% 500,000 w/ SATA @ 20% |
1.5M w/ SCSI @ 100% |
1.5M w/ SCSI @ 100% |
|
Integrated Interconnect Options |
No |
Yes, optional 8-port Switch
or 3-port Hub (some restrictions) |
No |
|
Use for Storage |
Primary Storage with SCSI, Secondary with SATA |
Primary Storage with SCSI |
Primary Storage with SCSI |
|
|
Product Highlights
| Product Technology | Modular Chassis - The modular design of the MSA1500 controller shelf can support up to 4 single channel or 2 dual channel SCSI enclosures, 8 SATA enclosures on 4 dual channel SCSI I/O cards, redundant controllers, 2 Gb Fibre Channel I/O modules, fans and power supplies. Scalability - up to 16.8 TB storage capacity
utilizing 56 SCSI hard drives and four MSA30 SCSI enclosures or up to
64 TB* storage
capacity utilizing SATA hard drives and eight MSA20 SATA enclosures. Larger
drives are under investigation for possible future use. Performance - The MSA1500 cs and its components have been designed using the latest in standard 2 Gb interconnects and Fibre Channel technology. Performance is rated at a transmission rate of up to 30,000 IOPs from cache and bandwidth of up to 200 MB per second. Performance can be substantially impacted by number of users and type of application. With dual controller active/active configurations, performance increase to >41,000 IOP/s from cache and 350MB/s throughput. Fault Tolerance - RAID 6 with HP's Advanced Data Guarding technology (RAID ADG). This is the highest level of fault tolerance. It allocates two sets of parity data across drives and allows simultaneous write operations. This level of fault tolerance can withstand two simultaneous drive failures without downtime or data loss. DtS Architecture - DtS (Direct Attach to SAN) architecture is an exclusive MSA1000 and MSA1500 cs feature that provides a quick and easy way to migrate stored data on SCSI disks protected by most Smart Array controllers to a MSA1000 or MSA1500 storage system. Pre-Failure Warranty - Specific enclosures and hard drives attached
to an MSA1500 and monitored under Insight Manager are supported by a Pre-Failure
(replacement) Warranty. Integrated Configuration and Management Tools - The MSA1500 utilizes a standard, integrated set of management and utility software. Not available with all operating systems. Hot Plug Expansion and Replacement Support - The MSA1500 cs supports hot plug expansion and replacement of redundant controllers, fans, power supplies, Serial ATA and SCSI disk enclosures, and I/O cards for simple, fast installation and maintenance. |
|
|
Software Components
| Overview |
The MSA1500 utilizes a set of utility software for storage and RAID management, setup, configuration and troubleshooting. This reduces the cost of ownership by reducing the training and technical expertise necessary to install and maintain your HP storage solution. Not all operating systems allow use of all of tools. |
|
| |
| Array
Configuration Utility (OS dependent) |
|
|
| |
| Selective Storage Presentation
(SSP) |
|
|
|
|
| Insight Manager |
|
|
|
Compatibility
| HP's extensive compatibility testing program assures that your HP StorageWorks MSA1500 works with leading servers, operating systems, and backup applications - and not just those sold by HP. The MSA1500 works seamlessly in many environments, making them especially suitable if you have a mixed system environment. For the latest list of servers, workstations, operating systems, and backup software that supports the MSA1500, check the Modular Smart Array compatibility pages on our web site at: http://www.hp.com/go/MSA1500cs. | |
| HP Server Compatibility | The HP StorageWorks MSA1500 cs supported on the following servers, depending on the various operating systems: |
|
All ProLiant x86 and x86_64 servers fully supported unless noted below. NOTE: New models are in test ProLiant x86 servers ProLiant AMD Opteron servers ProLiant INTEL EM64T servers Integrity IA64 (Itanium) servers PA-RISC servers: Supported Alpha servers |
|
|
| |
| OS Support for Single controller or dual controller configurations with active/passive firmware |
Please refer to compatibility matrix at http://www.hp.com/go/msa1500cs for complete configuration support. |
|
|
|
| OS Support for Dual controller
active/active firmware v7.x (requires 2nd controller and free firmware download) |
Optional controller firmware is available for downloading at no cost from the HP MSA1500 Web Site that enables both controllers to operate in an active/active mode. The following are the only operating systems that have been tested and are supported with active/active functionality in a homogeneous configuration only. All dual active (active/active) controller support is homogeneous.
NOTE: HP Secure Path is not supported on active/active controller configurations. Industry standard failover methodology is employed. |
|
|
|
| HP-UX
support (specific guidelines) |
The MSA1500 for HP-UX supports dual active/active controller or single
controller configurations (Active/passive configurations are not supported).
HP-UX single controller support is enabled with the standard firmware
that ships with the MSA1500HP-UX implemented with dual active controllers
requires use of firmware available through a free download off the MSA1500
web site.
|
| | |
| Solution Offerings/Software Certifications | Clustering |
|
| Backup and Restore |
|
|
| Medical Imaging Management |
|
|
| Replication |
|
|
| Other |
|
|
|
|
||
| Optional Software | |
| HP StorageWorks Storage Mirroring |
OpenView Storage Mirroring is designed to take small-medium enterprises beyond periodic backup to provide continuous data protection with minimal data loss and immediate recovery from any disaster or system outage. Natural and man-made disasters can occur when you least expect it - serving as a reminders that with less than a moment's notice, volumes of data loss can be lost. To prevent data loss from failure, error, or disaster, HP StorageWorks Storage Mirroring software provides replication of your valuable Windows data, Exchange data, and SQL Data to another server. Proactive replication is a key strategy that can be coupled with tape backup and snapshot technology for continuous data protection and point-in-time copies of data. Having replicated data co-located, customers can recover their static and transactional data in seconds without loss of productivity. Storage Mirroring can also be utilized for disaster recovery, centralized backup, data distribution/mining, and server/storage migration..
For more information visit http://h18006.www1.hp.com/products/storage/software/sm/index.html |
|
|
|
|
|
| MSA1500 utilization of Industry Standard fail-over solutions |
HP supports additional high availability multi-pathing capabilities within various operating systems and through third-party vendors, providing continuous data access from HP's RAID MSA1500 to host servers. Options are available for servers running the Windows, Linux and HP-UX operating systems. More information and the explanation of restrictions are available at http://h18006.www1.hp.com/products/sanworks/multipathoptions/index.html
NetWare, OpenVMS, Tru64 UNIX utilize native OS_based failover software |
|
|
|
| HP StorageWorks
Secure Path (optional, only used with active/passive controller configurations if not deploying MPIO) |
HP StorageWorks Secure
Path is a family of high availability multi-pathing software products providing
continuous data access from the HP RAID Array to host servers running the
Windows Server 2003, Windows 2000, and Linux operating systems. Redundant hardware, advanced RAID technology and Secure Path's automated failover capability are used to enhance fault tolerance and availability. Secure Path effectively eliminates controllers, disk drives, interconnect hardware and host bus adapters as single points of failure in the storage subsystem. The attachment of non-Secure Path (single HBA) servers to a MSA1500 cs with dual controllers that has servers with Secure Path (dual HBA) attached is supported where the operating system is Windows or Netware. Users must realize that in event of a controller fail-over (failure of active controller) the single path servers will lose access to their data on the MSA1500 cs. |
|
|
NOTE: If Secure Path for Linux is used on any node attached to an MSA1500
cs, all nodes must also have Secure Path installed, regardless of operating systems.
NOTE: refer to http://www.hp.com/go/securepath for the latest Secure Path parameters. | ||
| Key Features |
| |
| | ||
| MSA1500 Clustering | Single
controller support | Active/passive
controllers support | Active/active
controllers support |
|
Windows, , Linux, NetWare
Heterogeneous HP-UX, SCO (homogeneous only) |
Windows, Linux, NetWare (heterogeneous) |
Windows, HP-UX, Linux, (heterogeneous)
Netware, SCO, Open VMS and Tru64 Unix (homogeneous) | |
|
In a single controller configuration or when dual controllers are configured as active/passive (standby), mixing clusters with single nodes is supported. For example you may mix three Microsoft (Windows Server 2003 or Windows 2000) clusters and other individual servers, even doing so in a heterogeneous server operating system environment. Windows Server 2003 allows a single cluster of up to eight nodes. To see Cluster Configuration Support Matrices that support the listings
on the Microsoft Windows Server Catalog, refer to: Single-path (single controller, non-Secure Path) NetWare clustering has been successfully tested up to a 12-node cluster. NetWare clusters employing Secure Path (dual controller, dual HBAs) are limited to six nodes. Multiple NetWare clusters (and single servers) may have concurrent access with no limitation inherent to the MSA1500 cs. Up to a 16-node Linux cluster (single controller, non-Secure Path) utilizing SteelEye LifeKeeper for Linux clustering software has been tested and is supported. Refer to http://www.hp.com/go/securepath for any restriction with Secure Path. Up to a 4-node HP-UX cluster (dual controller, non-Secure Path) utilizing HP-UX Service Guard clustering software has been tested and is supported. Refer to http://www.hp.com/go/MSA1500cs, the Compatibility Guide under technical documents under the support section. The MSA1500 has the ability to be configured with up to thirty-two LUNs.
A configuration of twenty attached servers has been tested and is supported.
More commonly, users have had an average of four to eight nodes. This
can be any combination of hosts or clusters with different operating systems
(while holding fast to the guidelines and limits described in the above
paragraphs. Performance within these guidelines is heavily dependent on
the actual number of end users and types of applications being employed. For more information, click on the link: http://h18004.www1.hp.com/products/storageworks/msa1500cs/index.html | |||
| | |||
| HP ProLiant Cluster HA/F200 for Entry Level SAN | The ProLiant Cluster F200 for the Entry Level SAN is designed to assist in simplifying the configuration of cluster solutions that provide high levels of data and applications availability in the Microsoft Windows Operating System environment through clustering to provide no-single-point-of-failure. The ProLiant Cluster F200 for the Entry Level SAN supports a two-node cluster based on Microsoft Windows 2000 Advanced Server and two to eight-nodes cluster based on Microsoft Windows Server 2003 Enterprise Edition operating system, the StorageWorks 1000 Modular Smart Array (MSA1000) and MSA1500 cs, or Raid Array RA4100 and ProLiant Servers. This solution also supports StorageWorks Secure Path management software. | |
| ProLiant
Cluster HA/F200 for the Entry Level SAN |
364026-B22 | |
| ProLiant Cluster HA/F200 for the Entry Level SAN (Japan) |
364026-292 | |
|
| ||
| HP ProLiant Cluster Starter Kit | The ProLiant Cluster Starter Kit is a ProLiant cluster "How-to-Guide" that includes documentation for ProLiant Clusters that use StorageWorks MSA1000, MSA1500 cs, EVA 3000, 4000,5000, 6000 and 8000. The kit provides documentation to set-up a Windows Full-Features MPIO Cluster. The kit also includes multimedia with animation to illustrate the actual components required to build a Fibre Channel Cluster and two 30-day trial licenses of OpenView Storage Mirroring. | |
| NOTE:
This kit does not include Secure Path Software. | ||
| HP ProLiant Cluster Starter Kit |
364023-B21 | |
|
| ||
| HP ProLiant Clusters for NetWare | HP supports a broad range of
solutions for NetWare Cluster services including configurations featuring
the MSA1500 cs and optionally with HP StorageWorks Secure Path. These solutions
provide high availability and maximum resource utilization for NetWare environments
from small file sharing implementations to enterprise business computing.
Single-path (single controller, non-Secure Path) NetWare clusters of up
to 12-nodes have been successfully tested. Presently 2-node NetWare clusters
with Secure Path have been tested and approved with larger NetWare cluster
testing planned. Multiple NetWare clusters are allowed. NOTE: SCSI Disk Technology Only. NOTE: Refer to http://www.hp.com/go/securepath for the latest Secure Path for NetWare parameters. |
|
|
Configure to Order Program Information
| HP introduces the Configure to Order program on a limited basis. It is not yet available in all areas. The MSA1500 and its options may or may not be factory installed in a rack with add-on controllers, switches, hubs, MSA20 enclosures, MSA30 enclosures, and hard drives. The MSA1500 cs may be integrated with 64-bit Integrity and PA-RISC servers or ProLiant or as standalone storage. | ||
| Configure to Order | Products Approved for CTO |
Part Number
|
| 1500 cs Modular Smart Array NOTE: 0D1 will appear after this part number on your sales order when factory integration is indicated. |
AA986A
|
|
| HP MSA1000 Controller 256 cache
ALL NOTE: 0D1 will appear after this part number on your sales order when factory integration is indicated. |
218231-B22
|
|
| 256 MB Cache Upgrade NOTE: 0D1 will appear after this part number on your sales order when factory integration is indicated. |
254786-B21
|
|
| MSA1500 cs Fibre Channel I/O Module NOTE: 0D1 will appear after this part number on your sales order when factory integration is indicated. |
AA987A
|
|
| MSA1500 cs Dual Channel SCSI I/O
Module NOTE: 0D1 will appear after this part number on your sales order when factory integration is indicated. |
AA988A
|
|
|
|
||
| NO CTO Available (No Kits or Bundles) |
MSA1500 HP-UX Dual Controller SCSI SAN Starter Kit |
AG704A
|
| MSA1500 HP-UX Dual Controller SATA SAN Starter Kit |
AG705A
|
|
| MSA1500 HP-UX SCSI SAN Starter Kit (Single Controller) |
AG706A
|
|
| MSA1500 HP-UX SATA SAN Starter Kit (Single Controller) |
AG707A
|
|
| MSA1500 HP-UX High Availability Kit (only for single controller kits) |
AG708A
|
|
| MSA1500 SAN SCSI G2 Starter Kit (NEW) |
AE327B
|
|
| MSA1500 SAN SATA Starter G2 Kit (NEW) |
AE326B
|
|
| MSA1500 SAN Starter Kit HA G2 Bundle (NEW) |
AE328B
|
|
| MSA1500cs 2U Fibre Channel SAN Attach Controller Shelf, with SATA |
AD509A
|
|
| MSA1500cs 2U Fibre Channel SAN Attach Controller Shelf, with SCSI |
AD510A
|
|
| MSA1500 cs upgrade shelf |
AD511A
|
|
|
|
Service and Support, HP Care Pack, and Warranty Information
| Warranty |
Options for the MSA1500 carry their own warranty. Refer to HP's Limited Warranty Statement for more information. The MSA1500 has been designed with customer self repairable parts to
minimize repair time and provide greater flexibility in performing defective
parts replacement. Please refer to HP's Limited Warranty Statement for
further details: Products included in various Kits carry their own individual warranties. NOTE: The warranty of the hard
drive options purchased with the MSA1500 cs product is different for
SCSI hard drives versus SATA hard drives. SCSI hard drive options have
a three year warranty and SATA hard drives options have a one year warranty.
|
|
| |
| Warranty Upgrade Options |
|
| | |
| HP Care Pack Information |
NOTE: Refer to Step 6 "Choose HP Care Pack Services" in the Configuration Information section below for all Service, Warranty Plans, Installation and Startup Services available for the MSA1500 For additional information on
Product Services and HP Care Pack, as well as orderable part numbers, please refer
to the URL: http://www.hp.com/hps/carepack/. |
| HP Care Pack Services | HP
Care Pack Services offer upgraded service levels to extend and expand your standard
product warranty with easy-to-buy, easy-to-use support packages that help you
make the most of your storage investments. http://www.hp.com/hps/storage/ns_san.html#services |
| | |
| Software Product Services | Product support provides the customer
access to HP's experienced technical support resources, as well as access to HP's Information Services database for support on a variety of multi-vendor/multiplatform software products. Product support includes escalation and problem coordination with the appropriate engineering group. HP Services offer a variety of options to allow you to tailor your product service to meet the needs of your organization. Basic warranty on products can be uplifted from day one to ensure you receive the service you need when you need it. |
| Warranty and Support |
HP warrants only that the software media will be free of physical defects
for a period of ninety (90) days from delivery.
|
| Secure Path Software Services |
|
| For additional software product
services information for HP Care Pack services, as well as orderable part
numbers, please refer to the URLs listed below: All storage services: http://www.hp.com/hps/storage/. All HP Care Pack Services: http://www.hp.com/hps/carepack/storage/cp_networked.html. Software Support HP Care Pack Services: http://www.hp.com/hps/carepack/software/cp_storage.html. Installation and Startup Services: http://www.hp.com/hps/storage/ns_implementation.html. If you have specific service questions contact your local HP representative. Contact information for your local area can be found at: http://welcome.hp.com/country/us/en/contact_us.html Maintenance releases, bug fixes and software patches are available at: http://welcome.hp.com/country/us/en/support.html. |
|
| | |
| Hardware Product Services |
For product services information for HP Care Pack services, as well as
orderable part numbers, please refer to the URLs listed below: |
| | |
| Array Installation and Startup Services |
The HP Installation and startup for HP StorageWorks Disk Arrays service
package provides installation and configuration of HP StorageWorks Disk
Array products. Service highlights include:
|
|
| |
| SAN Solution Service |
SAN Solution Service covers your entry-level disk array solution with:
The Array Installation and Startup service is a pre-requisite for the SAN Solution Service. For more information about he SAN solution service, please visit: http://www.hp.com/hps/storage/ns_san.html |
|
|
Kit Contents
| Model Name |
Contents' Description |
Part Number |
| MSA1500 cs |
MSA1500 controller shelf, 1-controller, 1- FC module,
1- SFP transceiver, 1- dual channel SCSI I/O card, 2- power cables, redundant
fans, redundant power supplies, universal rack-mounting kit, MSA1500 support
CD and documentation, serial cable.
NOTE: Fibre Channel cables, disk enclosures and hard drives are ordered separately. |
AA986A |
| MSA1500 cs with one SATA drive enclosure | 1- MSA1500 controller shelf base
configuration, and 1-MSA20 SATA disk enclosure base configuration. NOTE: For Americas, Asia Pacific, and Japan. |
AD509A |
| MSA1500 cs & MSA20 w/ 12 500GB SATA Bundle | MSA1500 cs Controller Shelf and
MSA20 Enclosure w/ 12ea. 500 GB SATA HDDs. NOTE: Available in Americas only. |
AJ685A *NEW* |
| MSA1500 cs & MSA20 w/ 12 750GB SATA Bundle | MSA1500 cs Controller Shelf and
MSA20 Enclosure w/ 12ea. 750 GB SATA HDDs. NOTE: Available in Americas only. |
AJ686A *NEW* |
| MSA1500 cs with one SCSI drive enclosure | 1- MSA1500 controller shelf base
configuration, and 1-MSA30 single-channel SCSI disk enclosure base configuration. NOTE: For Americas, Asia Pacific, and Japan. |
AD510A |
| MSA1500 cs & MSA30 w/ 14 300GB 10k SCSI Bundle |
MSA1500 cs Controller Shelf and
MSA30 Enclosure w/ 14ea. 300 GB 10K SCSI HDDs. NOTE: Available in Americas only. |
AJ689A *NEW* |
| MSA1500 SAN SCSI G2 Starter
Kit (NEW) (w/ PCI-E HBAs) |
(Windows or Linux compatible)
NOTE: Includes (1) MSA1500 (1) MSA30 SCSI drive enclosure (1) 4/8 Base SAN Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables. |
AE327B |
| MSA1500 SAN SATA Starter G2
Kit (NEW) (w/ PCI-E HBAs) |
(Windows or Linux compatible)
NOTE: Includes (1) MSA1500 (1) MSA20 SATA drive enclosure (1) 4/8 Base SAN Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables. NOTE: For Americas, Asia Pacific, and Japan only. |
AE326B |
| MSA1500 SAN Starter Kit HA
G2 Bundle (NEW) (w/ PCI-E HBAs) for both SCSI and SATA SAN Starter G2 Kits |
(Windows or Linux compatible)
NOTE: Includes (1) redundant controller; (1) FC I/O module; (1) 4/8 Base SAN Switch (4) 4Gb SFP transceivers (2) FC1142SR 4Gb PCI-E HBAs + cables. User will need to employ either Secure Path (active/passive configurations), QLogic failover, or Windows MPIO for path failover implementation. |
AE328B |
| MSA1500cs HP-UX Dual Controller SCSI SAN Starter Kit | (HP-UX compatible) NOTE: Includes (2) controllers; (1) MSA30 SB SCSI drive enclosure; (1) FC I/O module; (2) 9124 SAN Switch (8) 4Gb SFP transceivers (4) HP PCI-X 2.0 1Port 4Gb HBAs + cables. User will employ PVlinks for path failover implementation. |
AG704A *NEW* |
| MSA1500cs HP-UX Dual Controller SATA SAN Starter Kit | (HP-UX compatible) NOTE: Includes (2) controllers; (1) MSA20 SATA drive enclosure; (1) FC I/O module; (2) 9124 SAN Switch (8) 4Gb SFP transceivers (4) HP PCI-X 2.0 1Port 4Gb HBAs + cables. User will employ PVlinks for path failover implementation. NOTE: For Americas, Asia Pacific, and Japan. |
AG705A *NEW* |
| MSA1500cs HP-UX SCSI SAN Starter Kit | (HP-UX compatible) NOTE: Includes (1) controller; (1) MSA30 SCSI drive enclosure; (1) 9124 SAN Switch (4) 4Gb SFP transceivers (2) HP PCI-X 2.0 1Port 4Gb HBAs + cables. NOTE: For Americas, Asia Pacific, and Japan. |
AG706A *NEW* |
| MSA1500cs HP-UX SATA SAN Starter Kit | (HP-UX compatible) NOTE: Includes (1) controller; (1) MSA20 SATA drive enclosure; (1) 9124 SAN Switch (4) 4Gb SFP transceivers (2) HP PCI-X 2.0 1Port 4Gb HBAs + cables. NOTE: For Americas, Asia Pacific, and Japan. |
AG707A *NEW* |
| MSA1500cs HP-UX High Availability Kit | (HP-UX compatible) NOTE: Includes (1) redundant controller; (1) FC I/O module; (1) 9124 SAN Switch (4) 4Gb SFP transceivers (2) HP PCI-X 2.0 1Port 4Gb HBAs + cables. User will employ PVlinks for path failover implementation. NOTE: For Americas, Asia Pacific, and Japan. |
AG708A *NEW* |
| MSA1500 cs upgrade shelf | MSA1500 controller shelf, 1- dual channel SCSI I/O card, 2- power cables, redundant fans, redundant power supplies, universal rack-mounting kit, MSA1500 support CD and documentation, serial cable. | AD511A |
| NOTE: This MSA1500 cs upgrade shelf does not include a controller or a Fibre Channel I/O Module. It is intended for those customers who wish to upgrade from their MSA1000 to the MSA1500 cs. For each controller added to this shelf, one Fibre Channel I/O module (PN AA987A) is required. | ||
| NOTE: When upgrading to the MSA1500 cs, there is no space for the MSA1000 embedded switch or hub. | ||
| MSA Controller management cable | One ships standard. Orderable through HP Store or Service if original is lost | 316131-001 |
|
|
Configuration Information
| Step 1 - Base Configuration | ||
| Select one: | ||
| Model Name | Model Description: | Part
Number |
| MSA1500
cs | MSA1500 controller shelf, 1-controller, 1- FC module, 1- SFP transceiver, 1- dual channel SCSI I/O card, 2- power cables, redundant fans, redundant power supplies, universal rack-mounting kit, MSA1500 cs support CD and documentation, serial cable. |
AA986A |
|
| ||
| Step 2 - Required Options (Choose Serial ATA or SCSI) | ||
| Select each required option with quantities specified. *NOTE: SATA drives are designed for archival or reference data. They should not be used in a heavy or intense I/O environment. Those situations require the use of enterprise-class SCSI drives. | ||
| Description with Parts Shipped: |
Quantity
|
Part Number
|
| Dual Channel SCSI I/O Module (1 ships with base unit, 3 more can be added) |
Up to 4
|
AA988A
|
| MSA20 - Serial ATA enclosure, SCSI cable, redundant fans and power supplies, power cable |
Up to 8
|
335921-B21
|
|
HP 250GB 1.5G SATA 7.2K 3.5" HDD |
Up to 12 per MSA20 enclosure
|
349239-B21
|
|
HP 500GB 1.5G SATA 7.2K 3.5" HDD |
Up to 12 per MSA20 enclosure
|
395473-B21
|
| HP 750GB 1.5G SATA 7.2K 3.5" HDD |
Up to 12 per MSA20 enclosure
|
432341-B21
|
| MSA30 - Dual Channel SCSI enclosure, SCSI cable, redundant fans and power supplies, power cable |
Up to 2
|
302970-B21
|
| MSA30 - Single Channel SCSI enclosure, SCSI cable, redundant fans and power supplies, power cable |
Up to 4
|
302969-B21
|
| HP 72GB U320 10K Universal HDD |
Up to 14 per MSA30 enclosure
|
286714-B22
|
|
HP 146GB U320 10K Universal HDD |
Up to 14 per MSA30 enclosure
|
286716-B22
|
|
HP 300GB U320 10K Universal HDD |
Up to 14 per MSA30 enclosure
|
350964-B22
|
|
HP 36GB U320 15K Universal HDD |
Up to 14 per MSA30 enclosure
|
286776-B22
|
|
HP 72GB U320 15K Universal HDD |
Up to 14 per MSA30 enclosure
|
286778-B22
|
|
HP 146GB U320 15K Universal HDD |
Up to 14 per MSA30 enclosure
|
347708-B22
|
| HP 300GB U320 15K Universal HDD |
Up to 14 per MSA30 enclosure
|
411089-B22
|
| NOTE:
Larger SATA hard drives are currently in qualification but are not presently
supported. NOTE: Two SATA disk enclosures can be attached to one SCSI I/O module. Only one SCSI disk enclosure can be attached to a SCSI I/O module. NOTE: It is recommended that the same hard drive capacity (ex. All 250 GB SATA in SATA enclosure or all 146 GB SCSI in SCSI enclosure) be installed in a RAID-set. NOTE: All Ultra320 Universal Hard Drives are backward compatible to U2 or U3 speeds. NOTE: For complete compatibility information, refer to the Compatibility table located at http://www.hp.com/go/msa1500cs |
||
|
|
||
| Must choose optional Power Cord for Non-U.S. Configurations |
Quantity
|
Part Number
|
| Power Cord, 110/220 VAC, US/Canada/Mexico NOTE: Shipped standard with all units. |
2
|
227099-001
|
| Power Cord, 220/240 VAC, (US/Canada/Mexico) |
2
|
227099-002
|
| Power Cord, (Australia/China/New Zealand) |
2
|
227098-011
|
| Power Cord, (Central Europe) |
2
|
157215-021
|
| Power Cord, (United Kingdom/Hong Kong) |
2
|
157216-031
|
| Power Cord, (Switzerland) |
2
|
157219-111
|
| Power Cord, (Italy) |
2
|
157217-061
|
| Power Cord, (Denmark) |
2
|
157218-081
|
| Power Cord, (Japan) |
2
|
139867-006
|
| Power Cord, (South East Asia/India) |
2
|
157220-AR1
|
| NOTE: Redundant configurations require two Host Bus Adapters per server, an additional controller and fibre channel I/O module, and Secure Path or industry standard MPIO failover software for each server. | ||
|
|
||
|
Step 3 Choose Redundant MSA1500 System Options
|
||
|
Description
|
Quantity
|
Part Number
|
|
MSA Controller
NOTE: The MSA1500 utilizes the MSA1000 controller with specific firmware |
1
|
218231-B22
|
|
256 MB Cache Modules for Controller (one additional for
each controller)
NOTE: The MSA1500 and MSA1000 utilize the same Cache Modules |
2
|
254786-B21
|
|
MSA1500 Fibre Channel I/O module
|
1
|
AA987A
|
|
HP StorageWorks Secure Path (available for active/passive
configurations only) or an industry standard path failover solution such
as Windows MPIO or QLogic Failover for Linux (appropriate for the operating
system)
|
||
| NOTE: Redundant configurations require two Host Bus Adapters per server, an additional controller and fibre channel I/O module, redundant switches and cables, and Secure Path (active passive configuration) software or Industry Standard failover depending on the operating system for each server. | ||
|
|
||
|
Step 4 – Choose Supported Infrastructure Options
|
||
| Select each required option with quantities specified. | ||
| Description with Parts Shipped: |
Part Number
|
|
| 4 Gb Fibre Channel Fabric "B-Series" family of switches | 4 Gb SFP SW Transceiver Kit |
A7446B
|
| HP StorageWorks 4/8 Base SAN Switch 8 port 4Gb/s switch with zero e-ports |
A7984A
|
|
| HP StorageWorks 4/8 SAN Switch 4Gb/s with full fabric |
A8000A
|
|
| HP StorageWorks 4/16 SAN Switch |
A7985A
|
|
| HP StorageWorks 4/16 SAN Switch Power Pack |
A7987A
|
|
| HP StorageWorks 4/32 SAN Switch Power Pack |
A7394A
|
|
| HP StorageWorks 4/32 Full SAN Switch |
A7393A
|
|
| HP StorageWorks 4/32 Base SAN Switch |
A7537A
|
|
| HP StorageWorks 4/8 4 port upgrade license |
T4260A
|
|
| 4/64 SAN Switch Power Pack 4/64 SAN Switch with 32 active ports |
AE496A
|
|
| 4/64 SAN Switch with 64 active ports |
AG457A
|
|
| HP StorageWorks Full Fabric license |
T4261A
|
|
| HP StorageWorks B-Series 8-31 port Power Pack License |
T3573A
|
|
| 4/64 SAN Switch with 32 active ports |
AE495A
|
|
| 16 port upgrade license for 4/64 SAN Switch (base model) and Power Pack model |
T4411A
|
|
| StorageWorks 4/256 SAN Director |
A7988A
|
|
| StorageWorks 4/256 SAN Director Power Pack |
A7989A
|
|
| HP StorageWorks SAN Director 4/16 Blade |
A7990A
|
|
| HP StorageWorks SAN Director 4/32 Blade |
A7991A
|
|
| HP StorageWorks B-Series MP Router Blade |
AG461A
|
|
| Power Pack Software Upgrade Bundle |
330882-B21
|
|
| StorageWorks SAN Director Blade |
AD504A
|
|
| HP StorageWorks SAN Director 4/16 Blade |
A7990A
|
|
| Brocade 4Gb SAN Switch for HP p-Class BladeSystem, Base |
A7533A
|
|
| Brocade 4Gb SAN Switch for HP p-Class BladeSystem, Full Fabric |
A7534A
|
|
| Brocade 4Gb SAN Switch for HP p-Class BladeSystem, Power Pack |
A7535A
|
|
| Brocade 4/12 SAN Switch (1) 4Gb SAN Switch; 12 ports enabled for any combination (internal and external); two (2) short wave 4Gb SFPs; |
AE370A
|
|
| Brocade 4/24 SAN Switch (1) 4Gb SAN Switch; 24 ports enabled (16 internal, 8 external); four (4) short wave 4Gb SFPs; |
AE372A
|
|
| Brocade 4/24 SAN Switch Power Pack (1) 4Gb SAN Switch; 24 ports enabled (16 internal, 8 external); four (4) short wave 4Gb SFPs; |
AE371A
|
|
|
|
||
| 2 & 4Gb Fibre Channel Fabric "C-Series" family of switches | Cisco MDS 9124e 12-port Fabric
Switch |
AG641A
|
| Cisco MDS 9124e 24-port Fabric Switch |
AG642A
|
|
| Cisco MDS 9120 2Gb Fabric Switch w/0 SFPs |
A7426A
|
|
| Cisco MDS 9140 2Gb Fabric Switch w/0 SFPs |
A7427A
|
|
| Cisco MDS 9124 8-ports Active Fabric Switch w/0 SFPs |
AG646A
|
|
| Cisco MDS 9124 16-ports Active Fabric Switch w/0 SFPs |
AG647A
|
|
| Cisco MDS 9124 24-ports Active Fabric Switch w/0 SFPs |
AG648A
|
|
| Cisco MDS 9513 4Gb Director |
AE376A
|
|
| Cisco MDS 9506 4Gb Director w/Supervisor 2 |
AE388A
|
|
| Cisco MDS 9020 4Gb Fabric Switch w/0 SFPs |
AE377A
|
|
| Cisco MDS 9216i w/0 1Gb Ethernet SFPs |
AE390A
|
|
| Cisco MDS 9509 Director w/Supervisor 2 |
AE389A
|
|
|
|
||
| 2 Gb Fibre Channel HBAs | FCA2214 2Gb Host Adapter (Linux, NetWare, SCO & 32-bit Windows) |
281541-B21
|
| FCA2214DC dual channel 2Gb Host Adapter (Linux, NetWare, SCO & 32-bit Windows) |
321835-B21
|
|
| Windows 32-bit single channel 2Gb PCI-X (Windows Server 2003, W2K) |
A7388A
|
|
| Windows 32-bit dual channel 2Gb PCI-X (Windows Server 2003, W2K) |
A7387A
|
|
| Host Adapter for Windows Server 2003 64-bit, Integrity servers, single channel 2 Gb PCI-X |
AB467A
|
|
| Host Adapter for Windows Server 2003 64-bit, Integrity servers, dual channel 2 Gb PCI-X |
AB466A
|
|
| Host adapter Q2300 2Gb 64-bit PCI-X for Linux, Integrity servers |
A7538A
|
|
| Host adapter 2Gb PCI-X Dual channel for HP-UX and Linux, Integrity servers |
A6826A
|
|
| HP-UX HBA: PCI 2GB Fibre Channel Adapter |
A6795A
|
|
| HP PCI-X 2-port 2Gb Fibre Channel and 2-port 1Gb Ethernet |
AB465A
|
|
| HP-UX HBA: PCI-X 2Gb Fibre Channel/1000Base-T |
A9784A
|
|
| HP-UX HBA: PCI-X 2Gb Fibre Channel/1000Base-SX |
A9782A
|
|
| FCA2684 PCI-X Single Channel 2Gb Host Adapter for OpenVMS & Tru64 UNIX AlphaServers |
DS-A5132-AA
|
|
| FCA2684DC PCI-X Dual Channel 2Gb Host Adapter for OpenVMS & Tru64 UNIX AlphaServers |
DS-A5134-AA
|
|
|
|
||
| 4 Gb Fibre Channel HBAs | HP StorageWorks FC2142SR HBA 4Gb PCI-e for Windows, Linux |
A8002A
|
| HP StorageWorks FC2242SR DC HBA 4Gb PCI-e for Windows, Linux |
A8003A
|
|
| HP StorageWorks FC1142 4Gb PCI-e HBA for Windows, Linux |
AE311A
|
|
| HP StorageWorks FC1242 4Gb PCI-e DC HBA for Windows, Linux |
AE312A
|
|
| HP StorageWorks FC2143 4Gb PCI-X 2.0 HBA for Windows, Linux |
AD167A
|
|
| HP StorageWorks FC2243 4Gb PCI-X 2.0 DC HBA for Windows, Linux |
AD168A
|
|
| HP StorageWorks FC1143 4Gb PCI-X 2.0-to-Fibre Channel Host Bus Adapter for x86, x64 and ia64 Windows and Linux. |
AB429A
|
|
| HP StorageWorks FC1243Dual Channel 4 Gb PCI-X 2.0-to-Fibre Channel Host Bus Adapter for x86, x64 and ia64 Windows and Linux. |
AE369A
|
|
| HP PCI-X 2.0 1Port 4Gb Fibre Channel HBA |
AB378B
|
|
| HP PCI-X 2.0 2Port 4Gb Fibre Channel HBA |
AB379B
|
|
| HP-UX PCI-X single-channel, 4Gb fibre channel adapter |
AB378A
|
|
| HP-UX PCI-X dual-port, 4Gb fibre channel adapter |
AB379A
|
|
| Fibre Channel cables for 2 Gb Infrastructure | Use 2 Gb Fibre Channel cables when connecting the MSA Fibre Channel I/O Module to FCA2101 HBA(s) | |
| 2 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B21
|
|
| 5 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B22
|
|
| 15 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B23
|
|
| 30 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B26
|
|
| 50 m LC-LC Multi-Mode Fibre Channel Cable |