Overview
|
HP StorageWorks Modular Smart Array 500 G2
| |||||
| 1. Display | 5. Power Switch | ||||
| 2. Display Buttons | 6. Status Indicators | ||||
| 3. Display Indicators | 7. Redundant Controller Slot Blank | ||||
| 4. Modular Smart Array Controller | 8. Drive Bay(s) | ||||
|
|
|||||
| 1. Power Supply/Blower Indicators | 4. SCSI Port B | ||||
| 2. Power Supply/Blower Assemblies | 5. SCSI I/O Indicators | ||||
| 3. SCSI Port A | 6. SCSI I/O with Integrated Environmental Monitoring Unit (EMU) | ||||
|
|
|||||
| What's New |
|
|
|
| At A Glance |
|
|
|
Standard Features
| Modular Smart Array Family |
|
The HP StorageWorks Modular Smart Array
family delivers simple, affordable storage technology to meet today's
demanding and growing IT needs. These storage solutions offer the best
price/performance and best price/availability features for direct attach
environments, small clusters, workgroups and entry-level SAN environments.
Each solution is designed to be easy to deploy, secure, reduce management
costs, while driving rapid return on investment.
|
| |
| Modular Smart Array 500 G2 |
|
|
|
Product Highlights
| Modular Smart Array 500 G2 Highlights | |
| High Levels of Performance, Data Protection and Functionality |
|
| | |
| DtS (DAS to SAN) Technology |
The Smart Array architecture provides a quick and easy way to migrate from the Modular Smart Array 500 G2 to the Modular Storage Array 1000 (MSA 1000) for additional scalability. In order to convert the Modular Smart Array 500 G2 to a FC SAN, simply remove the Modular Smart Array Controller(s) and replace them with StorageWorks MSA1000 Controller(s) (218231-B22) and add FC I/O module(s) (218960-B21) or FC Switch(es) (288247-B21). By doing so the user can save their investment in the basic chassis and all their drives. A full back-up and restore IS NOW REQUIRED when migrating from an MSA500 G2 to an MSA1000. Prior to the current shipping firmware the customer was not dependent on doing a restore to move the data, now it does require a restore. |
| | |
| Low Total Cost of Ownership | The modular, scalable design of the Modular Smart Array 500 provides an extremely flexible platform. You can buy what you need today and purchase additional capacity and performance as your data storage needs grow, instead of making a large up-front investment. Additional drives, controllers, and cache can be easily added as your needs dictate.
|
|
|
Modular Smart Array 500 G2 Components
| Modular Smart Array 500 G2 Enclosure | The 4U array houses up to fourteen 1" Universal hot pluggable Ultra320, Ultra3 and/or Ultra2 drives. Each Modular Smart Array 500 G2 includes the following standard components: Modular Smart Array 500 G2 Controller, 2-port Ultra320 SCSI I/O Module, dual hot pluggable fans/power supplies, two power cables, two Ultra320 SCSI host adapters (SA-642), two VHDCI SCSI cables and a crossover Ethernet cable for clustering. |
| | |
| Modular Smart Array 500 G2 Controller | The Modular Smart Array 500 G2 Controller is an integrated RAID controller with an integrated LCD/LED status display and 256-MB read/write battery-backed cache (expandable to 512MB per controller). One Modular Smart Array 500 G2 Controller is included with the Modular Smart Array 500 G2; the redundant Modular Smart Array 500 G2 Controller is an option. |
| | |
| Modular Smart Array 500 G2 HBA | The Modular Smart Array 500 G2 HBA is a Smart Array 642 that offers two Ultra320 SCSI channels. An external channel for connectivity to the MSA500 G2 systems and an internal channel to provide RAID protection to Disk internal to the ProLiant server. The SA-642 is a 64-bit PCI-X card backward compatible with 64 bit PCI slots. |
| | |
| MSA500 G2 4-Port I/O Module with Smart Array Multipath |
The MSA500 G2 4-Port I/O Module option offers 4 Ultra320 ports to extend connectivity to up to 4 hosts or supporting multipath configurations. It frees captive storage capacity dedicated to a single server and increase storage utilization over internal server storage.
|
|
| |
| Smart Array Multipath Software |
The Smart Array Multipath software included with the MSA500 G2 4-port I/O Module or the High Availability Kit provides an additional level of fault tolerance by adding redundancy and performance to both the HBA in the host server as well as the SCSI cables connecting the host servers to the shared storage. Smart Array Multipath software delivers dual path functionality and supports failover capabilities for redundant host bus adapters (HBAs). When an HBA failure occurs, the software moves the logical drives from the path of the failed HBA to the path of the redundant HBA located in the same server.
|
|
| |
| Modular Smart Array 500 G2 Controller Management Features |
|
|
| |
| Controller Firmware Cloning | Enhanced Controller Firmware Auto-Cloning allows customer choice of controller firmware version when adding redundant controller with different firmware version. Easy to manage functionality through controller LCD panel at time of installation. |
|
|
|
| Multi Host Storage Sharing | Selective Storage Presentation (SSP) support standard on both the base 2-port model of Modular Smart Array 500 G2 as well as the optional MSA 500 G2 4-port I/O Module. SSP allows the administrator to create volumes and assign access rights to a particular host server. This allows sharing the Modular Smart Array 500 G2 with up to 4 host servers maximizing storage capacity utilization. SSP also allows online capacity expansion as well as online volume extension in DAS configurations. |
|
| |
| RAID |
Several fault tolerant configurations keep data available and servers running
while drives are being replaced, including:
|
|
| |
| Modular Smart Array 500 G2 Cache Upgrade and Fault Recovery |
Controller Cache Upgrade |
|
| Fault Recovery |
|
|
|
|
||
| Ultra320 SCSI I/O Module |
NOTE: For additional information regarding
ProLiant Server compatibility, please refer to the following URL: |
|
|
Software Components
| The Modular Smart Array 500 G2 utilizes a single, consistent set of utility software for storage and RAID management, setup, configuration and troubleshooting. This consistency reduces the cost of ownership by reducing the training and technical expertise necessary to install and maintain your HP server storage solution. | |
| Configuration Utilities | Array Configuration Utility
(ACU) [On-line for Microsoft and Linux, Remote Web-Based & Off-line,
CPQONLIN for NetWare On-line configuration] Option ROM Configuration for Arrays (ORCA) |
| Management/ Health Utilities | System Insight Manager |
| | |
| Array
Configuration Utility (ACU) |
|
| | |
| System Insight Manager |
|
| | |
| Supported
Operating Systems |
UnitedLinux 1.0 (including SuSE Linux Enterprise Server 8) |
|
| |
| Supported
Clustering Solutions |
UnitedLinux = Conectiva Linux Enterprise Edition, SCO Linux 4.0, SuSE
Linux Enterprise 8 and TurboLinux 8 all powered by UnitedLinux 1.0 |
|
|
Services and Support, HP Care Packs and Warranty Information
| Service and Support |
Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Limited warranty includes
3 year parts, 3 years labour, 3 years on-site support A full range of HP Care Pack hardware and software services are available including:
NOTE: For more information on HP Care
Pack services, contact any of our worldwide sales offices or resellers
or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack. NOTE: The information contained
herein is subject to change without notice and is provided "as is"
without warranty of any kind. |
|
| |
| HP
Care Pack Fixed Price Care Pack |
3 Yr 4h 13x5 |
U6455E
|
| 3 Yr 4h 24x7 |
U6456E
|
|
| 3 Yr 6h CTR |
U6457E
|
|
| 1 Yr 4h 13x5 |
U8148E
|
|
| 1 Yr 4h 7x24 |
U8149E
|
|
| 1 Yr 6h CTR |
U8150E
|
|
| Hardware Installation |
U6458E
|
|
|
|
||
| HP
Care Pack Flexible Care Pack |
Support - MSA500, 1 Yr ND Hardware |
HA101A1-7GN
|
|
Support - MSA500, 3 Yr ND Hardware |
HA101A3-7GN
|
|
| Support - MSA500, 1 Yr 4h 13x5 Hardware |
HA103A1-7GN
|
|
| Support - MSA500, 3 Yr 4h 13x5 Hardware |
HA103A3-7GN
|
|
| Support - MSA500, 1 Yr 4h 2x7 Hardware |
HA104A1-7GN
|
|
| Support - MSA500, 3 Yr 4h 24x7 Hardware |
HA104A3-7GN
|
|
| Support - MSA500, 1 Yr 6h CTR Hardware |
HA105A1-7GN
|
|
| Support - MSA500, 3 Yr 6h CTR Hardware |
HA105A3-7GN
|
|
| Support - MSA500, 1 Yr Support Plus |
HA109A1-7GN
|
|
| Support - MSA500, 3 Yr Support Plus |
HA109A3-7GN
|
|
| Support - MSA500, 1 Yr Support Plus 24 |
HA110A1-7GN
|
|
| Support - MSA500, 3 Yr Support Plus 24 |
HA110A3-7GN
|
|
| Support - MSA500, Installation |
HA113A1-564
|
|
|
Configuration Information
| Step 1: Order Required Items |
|
Models
|
HP Modular Smart Array 500 G2 (includes 2 HBA Adapters) |
335880-B21
|
|
|
||
|
Package Contents
|
Modular Smart Array 500 G2 Chassis | |
| Modular Smart Array 500 G2 Controller with 256MB cache | ||
| 2-port Ultra320 SCSI I/O Module | ||
| Redundant Hot Pluggable Power Supply/blower assemblies | ||
| 2 HBA - Smart Array 642 Adapters | ||
| Modular Smart Array 500 G2 Rack Mounting Kit | ||
| Modular Smart Array 500 G2 Support Software or Smart Start | ||
| Power cables (2) | ||
| VHDCI SCSI cables 6' each (2) | ||
| Crossover Ethernet cable for clustering | ||
| User Manual | ||
|
|
||
| Step 2: Choose Modular Smart Array 500 G2 System Options |
|
Options
|
Modular Smart Array 500 G2 High Availability Kit (includes MSA500 G2 controller, MSA500 G2 4-port IO Module, Smart Array Multipath Software and 2 SA-642 Adapters) |
360229-B21
|
| Modular Smart Array 500 G2 Controller | 335881-B21 | |
| MSA500G2 4-Port I/O Module with Smart Array Multipath Software |
335882-B21
|
|
| 256MB Battery Backed Cache Module |
254786-B21
|
|
| M-Series Rack Rail Kit Option |
313877-B21
|
|
|
|
||
| Step 3: Choose ProLiant Server(s) |
|
Server Compatibility
|
ML350 G3, G4, G5 |
|
| ML370 G3, G4, G5 |
||
| ML530 G2 |
||
| ML570 G2, G3, G4 |
||
| DL360 G3, G4, G5 |
||
| DL380 G3, G4, G5 |
||
| DL385 |
||
| DL560 |
||
| DL580 G2, G3, G4 |
||
| DL585, G2 | ||
| DL740 | ||
| DL760 G2 | ||
| For
additional information regarding ProLiant Server compatibility, please refer
to the following URL: http://www.hp.com/go/msa for latest compatibility |
||
|
|
||
| Step 4: Choose Linux Clustering Configuration Options |
|
High Availability Software
|
HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 (2 node license cluster kit) |
305199-B26
|
| HP Serviceguard for Linux A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 (single license version) |
307754-B26
|
|
| SteelEye LifeKeeper
for Linux See http://h18004.www1.hp.com/solutions/enterprise/highavailability/linux/index.html |
||
| NOTE: Above options not required for Microsoft clustering, Novell clustering or non-clustered shared storage configurations | ||
|
|
||
| Step 5: Choose Hard Drives |
|
Pluggable, Universal Hard Drives
|
U320 SCSI - Hot Plug | |
| HP 72GB U320 10K Universal HDD | 286714-B22 | |
| HP 146GB U320 10K Universal HDD | 286716-B22 | |
| HP 300GB U320 10K Universal HDD | 350964-B22 | |
| HP 36GB U320 15K Universal HDD | 286776-B22 | |
| HP 72GB U320 15K Universal HDD | 286778-B22 | |
| HP 146GB U320 15K Universal HDD |
347708-B21
|
|
| HP 300GB U320 15K Universal HDD |
411089-B22
|
|
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. | ||
| NOTE: For complete compatibility information, refer to the HP SCSI Hard Drive Compatibility table located at http://www.compaq.com/products//hdd/hotplug.html | ||
|
|
||
| Step 6: Choose Rack Option |
| HP Rack 5000 Series (Metallic Carbonite) |
HP 5642 RACK-UNASSEMBLED |
358254-B21
|
| NOTE:
Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical
Specifications such as height, width, depth, weight, and colour: http://h18000.www1.hp.com/products/quickspecs/12074_ca/12074_ca.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: www.hp.com/go/rackandpower. |
||
|
|
||
| Rack Options for Rack 5000 Series | Stabilizer Kit for
5642 rack (Graphite Carbon) NOTE: The stabilizer kit is used to prevent rack from tipping over |
374493-B21
|
| Baying Kit for 5642
rack (Graphite Carbon) NOTE: The baying kit is used to join two or more HP 5642 racks. |
374499-B21
|
|
|
|
||
|
HP Rack 10000 Series (Graphite Metallic)
|
Rack, HP Infrastructure 42U (LV) |
379006-001
|
| Rack, HP Infrastructure 42U (HV) |
379005-001
|
|
| HP S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22
|
|
| HP 10842 (42U, 800mm wide) Rack Cabinet - Pallet |
257415-B21
|
|
| HP 10842 (42U, 800mm
wide) Rack Cabinet - Shock Pallet NOTE: Server Blade Enclosures must be field integrated into the 10842 racks. Factory integration of Server Blade Enclosures into the 10842 is not supported |
257415-B22
|
|
| HP 10647 (47U) Rack Cabinet - Pallet |
245160-B21
|
|
| HP 10647 (47U) Rack Cabinet - Shock Pallet |
245160-B23
|
|
| HP 10636 (36U) Rack Cabinet - Crated |
245163-B21
|
|
| HP 10622 (22U) Rack Cabinet - Shock Pallet |
245163-B22
|
|
| HP 10622 (22U) Rack Cabinet - Crated |
245163-B23
|
|
| NOTE:
xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. xxxxxx-B22
(shock pallet) used to ship racks with equipment installed (by custom systems,
VARs and Channels). xxxxxx-B23 (crated) used for air shipments of empty
racks. NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed |
||
| NOTE:
Please see the Rack 10000 QuickSpecs for additional part number and Technical
Specifications such as height, width, depth, weight, and colour: http://h18000.www1.hp.com/products/quickspecs/10995_ca/10995_ca.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: www.hp.com/go/rackandpower. |
||
|
|
||
| DtS Expansion Options |
|
SAN Conversion Options | HP
StorageWorks MSA1000 High Availability Upgrade Kit for Windows NOTE: Includes (1) redundant controller; (1) MSA SAN Switch 2/8; (2) FCA2214 HBAs; cables plus a ProLiant HA/F200 kit with Secure Path for two servers. Designed as an upgrade for the MSA500 G2 |
353804-B21 |
| HP
StorageWorks MSA1000 High Availability Upgrade Kit for Linux NOTE: Includes (1) redundant controller; (1) MSA SAN Switch 2/8; (2) FCA2214 HBAs; cables plus Secure Path for Linux Workgroup Edition for two servers. Designed as an upgrade for the MSA500 G2 |
353805-B21 | |
| Modular Smart Array 1000 Controller |
218231-B22 | |
| MSA Fibre Channel I/O Module |
218960-B21 | |
| MSA SAN Switch 2/8 (Integrated) |
288247-B21 | |
| FCA2101 Host Adapter (Microsoft) |
245299-B21 | |
| 2Gb/s SFP SW Transceiver Kit |
221470-B21 | |
| Modular Smart Array 30 Single Bus (rack-mountable) |
302969-B21 | |
| NOTE:
The MSA 1000 controller and the MSA 1000 Fibre Channel I/O module (or the
MSA SAN Switch 2/8) are required for conversion. To obtain conversion procedure
document go to http://www.hp.com/go/msa500
and download "Converting Modular Smart Array 500 to a Modular Smart Array
1000 for Additional Scalability document. |
|
|
Technical Specifications
| Modular Smart Array 500 G2 |
| LED Indicators on Front (3) | Power | |
| Fault detected in one or more sub-systems | ||
| Fault in Enclosure Management | ||
| LED Indicators for Drive Modules (3) | Drive Access (center) | |
| Online (left) | ||
| Drive Failure (right) | ||
| LED Indicators on Rear Panel (4) | Power Supply/Blower Assembly Fault (1) | |
| EMU (3): Power; A bus; B bus | ||
| Interface | Ultra320 SCSI to Hard Drives | |
| Ultra320 SCSI to Host Servers | ||
| Maximum Number of Drives | 14, 1-in Ultra320, Ultra3 or Ultra2 Universal Hard Drives (Modular Smart Array 500 G2 cabinet) | |
| Temperature Range | Operating | 50° to 95° F (10° to 35° C) |
| Shipping | -2°
to 122° F (-0° to 50° C) NOTE: Rated 1°C per 1000 feet of elevation to 10000 ft. | |
| Relative Humidity | Operating | 10% to 90% |
| Non-operating | Up to 95% | |
| Input Power Requirements | Rated Input Voltage | 100 to 240 VAC |
| Rated Input Frequency | 50 to 60 Hz | |
| Rated Input Current | 2.3 A at 120 VAC typical, 6A Maximum | |
| Input Power (max) | 549 W* | |
| Heat Dissipation (maximum) | 1876 Btu/hr* | |
| *Input Power and Heat Dissipation specifications are maximum values and apply to worst-case conditions at full rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment configuration. | ||
| 2-Port SCSI I/O Module | Ports | 2 VHDCI Ultra320 SCSI ports |
| Dimensions | 4.5 x 1.375 x 9.5 in (11.4 x 3.5 x 24.1 cm) | |
| Weight | 1.3 lb (0.6 Kg) | |
| Smart Array 642 Adapters | Protocol | Ultra320 SCSI |
| SCSI Electrical Interface | Low Voltage Differential (LVD) | |
| SCSI Port Connectors | One external and one internal SCSI port | |
| Channel Transfer Rate | 640-MB/s total; 320-MB/s per channel | |
| PCI Bus Speed | 64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth) | |
| PCI | 3.3 volt CPI slot compatibility only | |
| Dimensions (H x W x D) | 12.3 x 4.2 x 0.6 in (31.24 x 10.7 x 1.5 cm) | |
| Modular Smart Array 500 G2 Cabinet | 4U Rack Form Factor | |
| Dimensions (H x W x D) | 6.9 x 19 x 20.5 in (17.5 x 48.3 x 52.1 cm) | |
| Weight (Net) | 50 lb (22.5 kg) | |
| Shipping Packaging | Dimensions (L x W x D) | 33.7 x 14.8 x 33.8 in (85.6 x 37.5 x 85.9 cm) |
| Weight (Gross) | 70 to 105 lb (31.5 kg) | |
| | ||
| Modular Smart Array 500 G2 Controller |
| User Interface | Controller Display
with Status Indicators (2) and Push Buttons (4) Status Indicators on front of Controller (16) |
|
| Electrical Interface | LVD (Low Voltage Differential) | |
| Protocol Support | Wide Ultra320 SCSI (320 MB/s per channel) | |
| SCSI Channels | 4 total. 2 Ultra320 SCSI channels supporting up to 4 host servers. 2 Ultra320 SCSI channels supporting 14 disk drives (7 drives per channel). 640 MB/s maximum transfer rate | |
| Drives Supported | Up to 14 drives | |
| Maximum Capacity | 4.2 TB (14 drives x 300GB) | |
| Logical Drives | Up to 32 logical drives | |
| RAID Support | RAID ADG (Advanced Data Guarding) | |
| RAID 5 (Distributed Data Guarding) | ||
| RAID 1+0 (Striping & Mirroring) | ||
| RAID 1 (Mirroring) | ||
| RAID 0 (Striping) | ||
| Cache Memory | Standard 256 MB Read/Write Cache | |
| Up to 512 MB Read/Write with second 256MB cache module | ||
| ECC protection, battery-backed, and removable | ||
| NOTE:
The Modular Smart Array Controller allows the following cache configurations: 1 x 256 MB; 2 x 256 MB. |
||
| NOTE: When redundant controllers are installed, the cache configurations in both controllers must be identical. | ||
| Cache Batteries | Up to three days of redundant battery life, removable for easy replacement | |
| Upgradeable Firmware | 2 MB flashable ROM | |
| Disk Drive and Enclosure Protocol Support | Ulltra320, Ultra3 and Ultra2 SCSI 1-inch Universal drives | |
| Packaging | Dimensions (L x W x D) | 14.5 x 11.5 x 3.1 in (36.8 x 29.2 x 8 cm) |
| Weight (Gross) | 6 lb (2.72 kg) | |
|
|
||
| MSA500 G2 Shared Storage I/O Module (option) |
| Connector Type | VHDCI Ultra320 SCSI | |
| Ports | 4 Ultra320 SCSI | |
| Bandwidth | 320 MB/s per port | |
| Protocols/HBA Supported | Ultra320/Smart Array 642, Smart Array 6i adapters | |
| Software | Smart Array Multipath software 2.0B | |
| Packaging | Dimensions (L x W x D) | 14.5 x 11.5 x 3.1 in (36.8 x 29.2 x 8 cm) |
| Weight (Gross) | 6 lb (2.72 kg) | |
| | ||
| MSA500 G2 High Availability Kit (option) |
| Contents | MSA500 G2 Controller, 4-port Shared Storage I/O Module, 2 6ft. SCSI Cables, 2 SA-642 Adapters, and Smart Array Multipath Software 2.0B | |
| Packaging | Dimensions (L x W x D) | 18 x 12 x 10 in. (45.7 x 30.5 x 25.4 cm) |
| Weight (Gross) | 8 lb (3.6 kg) | |
| | ||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |