|
|
Overview
| HP ProLiant DL380 Generation 4 (G4)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| What's New |
|
Introducing the ProLiant DL380 G4 SAS model with the latest Dual-core
Intel Xeon Processors with Hyperthreading technology for maximum application
performance.
|
|
|
| At a Glance |
|
The HP ProLiant DL380, the world's largest selling server,
delivers on its history of design excellence with enterprise-class uptime
and manageability, proven 2-way Intel Xeon performance, and 2U density
for a variety of rack deployments and applications.
|
|
|
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor One of the following depending on Model |
Intel Xeon Processor 3.0 GHz/800MHz-2MB L2 |
| Dual-core Intel Xeon Processor
2.8 GHz/800MHz-2x2MB L2 NOTE: This kit is not backwards compatible, existing systems cannot be upgraded. |
|
| Intel Xeon Processor 3.2 GHz/800MHz-2MB L2 | |
| Intel Xeon Processor 3.4 GHz/800MHz-2MB L2 | |
| Intel Xeon Processor 3.6 GHz/800MHz-2MB L2 | |
|
|
|
| Cache Memory One of the following depending on Model |
2MB Level 2 cache |
| 2x2MB Level 2 cache (Dual-core Models) | |
|
|
|
| Upgradeability | Upgradeable to dual processing |
|
|
|
| Chipset |
Intel E7520 Chipset NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/. |
|
|
|
| Memory Protection |
Online spare Advanced ECC |
|
|
|
| Memory One of the following depending on model | Type | PC2-3200R 400MHz DDR2 |
| Standard (base models) | 1 GB (2 x 512 MB) | |
| Standard (High Performance models) | 2 GB (2 x 1024 MB) | |
| Maximum | 12 GB | |
| | ||
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter |
|
|
|
| PCI-X Non-Hot Plug Riser | ||||||
| Expansion Slots |
Slot
Number |
Bus Speed
|
Bus Number*
|
Device Number**
|
Hot Plug
|
PCI Voltage
|
|
1
|
64-bit/133MHz PCI-X |
10
|
1
|
no
|
3.3 Volt
|
|
|
2
|
64-bit/100MHz PCI-X |
6
|
1
|
no
|
3.3 Volt
|
|
|
3
|
64-bit/100MHz PCI-X |
6
|
2
|
no
|
3.3 Volt
|
|
| NOTE: The Smart
Array P600 Array Controller (SAS) with 256MB BBWC installed in Slot 1 on
SAS models. NOTE: Universal cards are supported. |
||||||
| PCI-X Hot Plug Riser (Optional) | ||||||
|
1
|
64-bit/133MHz PCI-X |
10
|
1
|
no
|
3.3 Volt
|
|
|
2
|
64-bit/100MHz PCI-X |
6
|
1
|
yes
|
3.3 Volt
|
|
|
3
|
64-bit/100MHz PCI-X |
6
|
2
|
yes
|
3.3 Volt
|
|
| NOTE: Universal cards are supported | ||||||
| PCI Express Non-Hot Plug
Riser (Optional on U320 SCSI Models only) |
||||||
|
1
|
PCI Express x4 |
8
|
0
|
no
|
NA
|
|
|
2
|
PCI Express x4 |
5
|
0
|
no
|
NA
|
|
|
NOTE: x8 cards are supported but will run at x4 speeds. |
||||||
|
|
||||||
| Storage Controller One of the following depending on model |
Smart Array 6i Controller (integrated on system board) |
| Smart Array P600/256 BBWC Controller (SAS Models) | |
|
|
|
| Storage | Diskette Drive |
1.44 MB Diskette Drive (optional on some models) |
| Optical Drive | 24x IDE CD-ROM (IDE DVD-ROM included on High performance models) | |
| Hard Drives | None Standard NOTE: U320 SCSI models can be operated in single channel or dual channel (2/4 split). SCSI configuration kit (364471-B21) is required for dual channel configurations. |
|
|
|
||
| Maximum Internal Storage Type | Hot Plug U320 SCSI |
1.8TB | 6 x 300GB with standard internal hot plug SCSI drive cage |
| Hot Plug SAS | 1.168TB | 8 x 146GB with standard internal hot plug small form factor SAS drive cage | |
|
|
|||
| Interfaces | Serial | 1 |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard | 1 | |
| External SCSI (VHDCI) | 1 NOTE: External VHDCI not included on SAS Models. |
|
| Network RJ-45 | 3 (1 for iLO) | |
| USB 2.0 Ports | 3 total: 1 front, 2 back NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
|
|
||
| Graphics | Integrated ATI Rage XL Video Controller with 8-MB SDRAM Video Memory |
|
|
|
| Form Factor | Rack (2U), (3.5-inch) |
|
|
|
| ProLiant Essentials Foundation Pack Software |
| |||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| NOTE: Flexible
and volume quantity license kits are available for ProLiant Essentials Value Packs.
Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials | ||||
| | ||||
| Industry Standard Compliance | ACPI 2.0 Compliant PCI 2.2 Compliant WOL Support Microsoft® Logo certifications USB 2.0 Support |
|
|
|
| Remote Management |
Integrated Lights Out (iLO) Standard Management:
Integrated Lights Out Advanced Pack (optional) Remote Graphical Console:
Remote Insight Lights-Out Edition II (optional) |
|
|
|
| Intelligent Manageability | HP Systems Insight Manager SmartStart Redundant ROM Remote Flash ROM Management Agent Integrated Management Log Automatic Server Recovery (ASR) Dynamic Sector Repairing (with Smart Array Controllers) Drive Parameter Tracking (with Smart Array Controllers) Hot Spare Boot (NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the system will automatically reboot and use the remaining good processor(s).) Pre-Failure Warranty (covers processors, SCSI hard drives and memory) |
|
|
|
| Server Power Cords | One Lowline NEMA power cord and One Highline IEC Power cord ships standard in most models. Smart Buys include one IEC power cable per power supply. |
|
| |
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable
matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. |
|
|
|
| Power Supply | 575 Watt, CE Mark Compliant Optional Hot Plug AC Redundant Power Supply |
|
|
|
| System Fans | 5 hot plug fans ship standard.
8 hot plug fans total supported internally for full redundancy NOTE: The additional 3 fans are available via Redundant Fan Option Kit (PN 293048-B21), this kit is included with all high performance, SAS models and 2MB cache models. |
|
|
|
| Required Cabling | For required cabling information,
refer to the Web site at: http://h18000.www1.hp.com/products/servers/proliantDL380/. |
| | |
| OS Support | Microsoft Windows Server 2000 Microsoft Windows Server 2003 Novell NetWare Red Hat Enterprise Linux SUSE Linux Enterprise Server SCO UnixWare, OpenServer VMware Virtualization Software |
| NOTE: For more
complete and up-to-date information on how to buy server operating systems
from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html. NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix at: http://www.hp.com/go/supportos. NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant DL380 G4, please see: http://h18023.www1.hp.com/support/files/server/us/index.html. NOTE: For more Linux OS support & certification information, please visit our the ProLiant & Bladesystem Server Linux matrix http://h18004.www1.hp.com/products/servers/linux/hpLinuxcert.html NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html. |
|
|
|
|
| Rack Airflow Requirements |
Rack 10000 series Cabinets
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/proliantdl380/index.html. | |
| | |
| Rack Kit | The HP ProLiant DL380 quick
deploy rail system provides tool-free support for racks with square or round
mounting holes (including Compaq/HP 7000*,
9000, 10000 and HP series), with an adjustment range of 24" - 36".
The ambidextrous cable management arm can be mounted on either the left
or right side for improved cable management. NOTE: Cable management arm must be removed to access hot-plug power supplies when the cable management arm is mounted on the right. *NOTE: High Airflow Inserts (High Air Flow Rack Door Insert for the 7142 Rack (single) PN: 327281-B21; or High Air Flow Rack Door Insert for the 7142 Rack (6-pack) PN: 327281-B22) are required to support the HP ProLiant DL380 G4 in 7000 series racks. The DL380 G4 Cable Management Arm is not supported on 7000 series racks. |
| | |
| Telco Rack Support | DL380 G4 Telco Rack Kit: Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions (http://www.racksolutions.com/hp/) |
| | |
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple
configuration, racking, installation, complex configuration and design services as well
as individual factory services, such as image loading, asset tagging, and
custom packaging. HP products supported through Factory Express include a wide
array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant
Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000,
VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. |
| | |
| HP Enterprise Configurator | The HP eCo-Enterprise Configurator
now provides factory default racking for our HP hardware portfolio. This
approach is aligned with our strategic direction to meet the needs and expectations
of our valued customers. If you require "custom" rack configuration,
please contact HP's Customer Business Center or an Authorized Partner for
assistance. http://www.hp.com/products/configurator |
| | |
| HP ProLiant Smart Buys |
The HP Smart Buy program offers mainstream business solutions at competitive prices with excellent availability and superior HP quality. It offers a wide range of industry-leading HP products at compelling prices, allowing you to receive richer configurations with additional options. NOTE: For detailed specification information on ProLiant Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf |
|
|
|
| Service and Support |
This product is covered by a global limited warranty and supported by
HP Services and a worldwide network of resellers and service providers.
Hardware diagnostic support and repair is available for three years from
date of purchase. Support for software and initial setup is available
for 90 days from date of purchase. Additional support may be covered under
the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services or customized service
agreements.
Continuous Care - Recommended service delivering cost-effective support
options designed to extend HP Services committed response and guaranteed
fix times, designed to speed problem identification and resolution.
Total Care - Highest HP Support service level recommend to help increase
IT performance and availability with comprehensive, integrated hardware
and software services
Deployment Services - HP Installation and Start Up services designed
to take time, risk, and worry out of the deployment of ProLiant servers
- and free customers IT support staff to focus on what they do best, their
business.
|
|
NOTE: For a complete listing of service
offerings and information visit: |
|
|
Models
| NOTE: For detailed specification information on ProLiant Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf. |
| SAS Models |
| DL380R04 X3.0-2MB/800,
1GB SAS 382483-001 |
Processor(s) | (1) Intel Xeon Processor 3.0 GHz (up to 2 supported) |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 1 GB (2 x 512 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array P600/256 BBWC Controller (installed in PCI-X slot) | |
| Hard Drive | None ship standard | |
| Internal Storage | 1.168TB max (with optional hard drives) | |
| Optical Drive | 24x IDE CD-ROM (Universal Media Bay) | |
| Diskette Drive | Optional | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans Standard | |
|
|
||
| DL380R04 X3.4-2MB/800,
1GB SAS 382484-001 |
Processor(s) | (1) Intel Xeon Processor 3.4 GHz (up to 2 supported) |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 1 GB (2 x 512 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array P600/256 BBWC Controller (installed in PCI-X slot) | |
| Hard Drive | None ship standard | |
| Internal Storage | 1.168TB max (with optional hard drives) | |
| Optical Drive | 24x IDE CD-ROM (Universal Media Bay) | |
| Diskette Drive | Optional | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans Standard | |
|
|
||
| DL380R04 X3.6-2MB/800,
2GB SAS High Performance 382485-001 |
Processor(s) | (2) Intel Xeon Processor 3.6 GHz |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 2 GB (2 x 1024 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array P600/256 BBWC Controller (installed in PCI-X slot) | |
| Hard Drive | None ship standard | |
| Internal Storage | 1.168TB max (with optional hard drives) | |
| Optical Drive | DVD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans
Standards Hot Plug Redundant Power Supplies Standard |
|
|
|
||
| DL380R04 X3.8-2MB/800,
1GB SAS 397628-001 |
Processor(s) | (1) Intel Xeon Processor 3.8 GHz (up to 2 supported) |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 1 GB (2 x 512 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array P600/256 BBWC Controller (installed in PCI-X slot) | |
| Hard Drive | None ship standard | |
| Internal Storage | 1.168TB max (with optional hard drives) | |
| Optical Drive | 24x IDE CD-ROM (Universal Media Bay) | |
| Diskette Drive | Optional | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans Standard | |
|
|
||
| U320 SCSI Models (Processors with 2MB Level 2 cache) |
| DL380R04 X3.8-2MB/800,
1GB 378741-001 |
Processor(s) | (1) Intel Xeon Processor 3.8 GHz (up to 2 supported) |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 1 GB (2 x 512 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Ultra320 Smart Array 6i Controller (integrated on system board) | |
| Hard Drive | None ship standard | |
| Internal Storage | 1.8TB max (with optional hard drives) | |
| Optical Drive | 24x IDE CD-ROM (Universal Media Bay) | |
| Diskette Drive | Optional | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans Standard | |
|
|
||
| DL380R04 X3.6-2MB/800,
1GB 378739-001 |
Processor(s) | (1) Intel Xeon Processor 3.6 GHz (up to 2 supported) |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 1 GB (2 x 512 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Ultra320 Smart Array 6i Controller (integrated on system board) | |
| Hard Drive | None ship standard | |
| Internal Storage | 1.8TB max (with optional hard drives) | |
| Optical Drive | 24x IDE CD-ROM (Universal Media Bay) | |
| Diskette Drive | Optional | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans Standard | |
|
|
||
| DL380R04 X3.4-2MB/800,
1GB 378737-001 |
Processor(s) | (1) Intel Xeon Processor 3.4 GHz (up to 2 supported) |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 1 GB (2 x 512 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Ultra320 Smart Array 6i Controller (integrated on system board) | |
| Hard Drive | None ship standard | |
| Internal Storage | 1.8TB max (with optional hard drives) | |
| Optical Drive | 24x IDE CD-ROM (Universal Media Bay) | |
| Diskette Drive | Optional | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans Standard | |
|
|
||
| DL380R04 X3.2-2MB/800,
1GB 378736-001 |
Processor(s) | (1) Intel Xeon Processor 3.2 GHz (up to 2 supported) |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 1 GB (2 x 512 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Ultra320 Smart Array 6i Controller (integrated on system board) | |
| Hard Drive | None ship standard | |
| Internal Storage | 1.8TB max (with optional hard drives) | |
| Optical Drive | 24x IDE CD-ROM (Universal Media Bay) | |
| Diskette Drive | Optional | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans Standard | |
|
|
||
| DL380R04 X3.0-2MB/800,
1GB 378735-001 |
Processor(s) | (1) Intel Xeon Processor 3.0 GHz (up to 2 supported) |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 1 GB (2 x 512 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Ultra320 Smart Array 6i Controller (integrated on system board) | |
| Hard Drive | None ship standard | |
| Internal Storage | 1.8TB max (with optional hard drives) | |
| Optical Drive | 24x IDE CD-ROM (Universal Media Bay) | |
| Diskette Drive | Optional | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans Standard | |
|
|
||
| DL380R04 X3.8-2MB/800,
2GB High Performance 378742-001 |
Processor(s) | (2) Intel Xeon Processor 3.8 GHz |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 2 GB (2 x 1024 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Ultra320 Smart Array 6i Controller (integrated on system board) with 128MB Battery Backed Write Cache (BBWC) and Duplex backplane standard (SCSI configuration kit) | |
| Hard Drive | None ship standard | |
| Optical Drive | DVD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans
Standards Hot Plug Redundant Power Supplies Standard |
|
|
|
||
| DL380R04 X3.6-2MB/800,
2GB High Performance 378740-001 |
Processor(s) | (2) Intel Xeon Processor 3.6 GHz |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 2 GB (2 x 1024 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Ultra320 Smart Array 6i Controller (integrated on system board) with 128MB Battery Backed Write Cache (BBWC) and Duplex backplane standard (SCSI configuration kit) | |
| Hard Drive | None ship standard | |
| Optical Drive | DVD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans
Standards Hot Plug Redundant Power Supplies Standard |
|
|
|
||
| DL380R04 X3.4-2MB/800,
2GB High Performance 378738-001 |
Processor(s) | (2) Intel Xeon Processor 3.4 GHz |
| Cache Memory | 2MB level 2 cache per processor | |
| Memory | 2 GB (2 x 1024 MB) of 2-way interleaved PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Ultra320 Smart Array 6i Controller (integrated on system board) with 128MB Battery Backed Write Cache (BBWC) and Duplex backplane standard (SCSI configuration kit) | |
| Hard Drive | None ship standard | |
| Optical Drive | DVD-ROM Drive | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| Form Factor | Rack (2U), (3.5-inch) | |
| Availability | Hot Plug Fully Redundant Fans
Standards Hot Plug Redundant Power Supplies Standard |
|
|
|
||
|
|
Configuration Information - Factory Integrated Models
|
NOTE: HP does not allow factory integration of options into standard
models listed above. | ||
| Step 1: Base Configuration | ||
| Models | HP ProLiant DL380G4 U320 SCSI Rack Chassis | 371293-405 |
| Factory Integrated Model ships with: | ||
| (6) U320 SCSI
Drive Bays Ultra320 Smart Array 6i Controller (integrated on system board) Embedded NC7782 PCI-X Gigabit Server Adapter Three available 64-bit PCI-X slots, including two non-hot plug 100MHz slots and one non-hot plug 133MHz slot 575 Watt hot plug power supply, CE Mark Compliant One Lowline NEMA power cord and One Highline IEC Power cord 5 hot plug fans Rack (2U), (3.5-inch) | ||
| HP ProLiant DL380G4 SAS Model Rack Chassis |
383891-405 | |
| Factory Integrated Model ships with: | ||
| (8) SFF Serial
Attached SCSI (SAS) Drive Bays Embedded NC7782 PCI-X Gigabit Server Adapter Three 64-bit PCI-X slots (2 available after SAS starter kit installed), including two non-hot plug 100MHz slots and one non-hot plug 133MHz slot 575 Watt hot plug power supply, CE Mark Compliant One Lowline NEMA power cord and One Highline IEC Power cord 8 hot plug fans Rack (2U), (3.5-inch) | ||
| | ||
| Step 1A: If SAS Model, Choose SAS Starter Kit or Controller (only one of the following) | ||
| SAS Controller | HP Smart Array
P600/256 BBWC Controller NOTE: This is a required selection if one of the two following SAS Starter Kits is not selected. If choosing this sku, SFF SAS hard drives must still be selected under Step 4. |
337972-B21 |
| SAS Starter Kit | SAS Starter Kit
- 36GB NOTE: Includes Smart Array P600/256 BBWC Controller and (2) 36GB SFF SAS Universal Hard Drives. |
396221-B21 |
| SAS Starter Kit
- 72GB NOTE: Includes Smart Array P600/256 BBWC and (2) 72GB SFF SAS Universal Hard Drives. |
396220-B21 | |
|
|
||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Intel X2.8-2MB/800MHz
DL380 G4 FIO BASE NOTE: If 2 processors are desired, select one 397645-L22 and one 397645-B21. Redundant Fan Kit (293048-B21) also required if choosing this processor with 371293-405. |
397645-L22 |
| Intel X3.8-2MB/800MHz
DL380 G4 FIO BASE NOTE: If 2 processors are desired, select one 378752-L22 and one 378752-B21 unless High Performance Model features are sought. If HPM features are desired, select one 378752-L22 and one 382618-001. Unless 382618-001 is selected, a Redundant Fan Kit (293048-B21) is also required if choosing this processor with 371293-405. |
378752-L22 | |
| Intel X3.0-2MB/800MHz
LV DL380 G4 FIO BASE NOTE: If 2 processors are desired, select one 397646-L22 and one 397646-B21. Redundant Fan Kit (293048-B21) also required if choosing this processor with 371293-405. |
397646-L22 | |
| Intel X3.0/800-2M
380 G4 FIO BASE NOTE: If 2 processors are desired, select one 378748-L22 and one 378748-B21. Redundant Fan Kit (293048-B21) also required if choosing this processor with 371293-405. |
378748-L22
|
|
| Intel X3.2/800-2M
380 G4 FIO BASE NOTE: If 2 processors are desired, select one 378749-L22 and one 378749-B21. Redundant Fan Kit (293048-B21) also required if choosing this processor with 371293-405. |
378749-L22
|
|
|
Intel X3.4/800-2M 380 G4 FIO BASE |
378750-L22
|
|
| Intel X3.6/800-2M
380 G4 FIO BASE NOTE: If 2 processors are desired, select one 378751-L22 and one 378751-B21 unless High Performance Model features are sought. If HPM features are desired, select one 378751-L22 and one 382617-001 or 391323-001 if SAS HPM model. Unless 382617-001 is selected, a Redundant Fan Kit (293048-B21) is also required if choosing this processor with 371293-405. |
378751-L22
|
|
| Base Memory | 1 GB of Advanced PC2 PC3200 DDR2 SDRAM DIMM Memory Kit (2 x 512 MB) |
343055-B21
|
| 2 GB of Advanced PC2 PC3200 DDR2 SDRAM DIMM Memory Kit (2 x 1024 MB) |
343056-B21
|
|
| 4 GB of Advanced PC2 PC3200 DDR2 SDRAM DIMM Memory Kit (2 x 2048 MB) |
343057-B21
|
|
|
|
||
| Step 3: Choose Additional Factory Integratable Options | ||
| Optical Drive | Slimline DVD-ROM Drive (8x/24x) Option Kit | 264007-B21 |
| Slimline CD-RW/DVD-ROM Combo Option Kit | 331903-B21 | |
| HP ProLiant Slim CD-ROM FIO Base | 338732-B21 | |
| Performance Packs | The HP ProLiant DL380 G4 performance packs are necessary to configure a HP ProLiant DL380 G4 High Performance Model. HP ProLiant DL380 G4 High Performance model includes the latest performance technologies and enterprise class availability features pre-installed for convenience and value. The performance pack includes a 2nd processor, redundant fans and power supplies, floppy drive, 128MB (U320 SCSI models) or 256MB (SAS models) of BBWC and the duplex backplane option for U320 SCSI (SCSI configuration kit). | |
| HP DL380G4 3.4/2M HPM Perf Pack FIO, US | 382616-001 | |
| HP DL380G4 3.6/2M HPM Perf Pack FIO, US | 382617-001 | |
| HP DL380G4 3.8/2M HPM Perf Pack FIO | 382618-001 | |
| HP DL380G4 3.6/2M SAS HPM Perf Pack FIO, US | 391323-001 | |
| HP DL380G4 X2.8-800-2x2M HPM Perf Pack FIO, US (Dual-core) | 399631-001 | |
|
|
||
| Step 4: Choose Additional Options for Factory Integration | ||
| NOTE: For additional options, please refer to the "Options" section below. |
|
|
Options
| NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. | ||
| HP ProLiant DL380 G4 Unique Options | PCI-X Hot Plug Riser Cage Option Kit |
354676-B21
|
| PCI Express Riser
Cage Option Kit NOTE: Not Supported on SAS models. For information about PCI Express visit: http://www.hp.com/servers/pci-express. |
354675-B21
|
|
|
|
||
| ProLiant
Essentials Value Pack Software |
ProLiant Essentials Intelligent Networking Pack | |
| ProLiant Essentials
Intelligent Networking Pack - Windows Edition, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
436225-B21 |
|
| NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_na/12062_na.html | ||
| ProLiant Essentials
Intelligent Networking Pack - Linux Edition, Single Server License |
436229-B21
|
|
| NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_na/12327_na.html | ||
| ProLiant Essentials Performance Management Pack | ||
| ProLiant Essentials
Performance Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation. NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp. |
306696-B21 |
|
| NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_na/11925_na.html | ||
| ProLiant Essentials Rapid Deployment Pack Windows Edition Release | ||
| Rapid Deployment
Pack, Single-Server License NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-B21 |
|
| ProLiant Essentials
Rapid Deployment Pack - Physical Media Kit |
434559-B21
|
|
| ProLiant Essentials Rapid Deployment Pack Flatpack - single-server license |
434560-B21
|
|
| NOTE:
For additional ProLiant Essentials Rapid Deployment Pack License Kits please
see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html |
||
| ProLiant Essentials Workload Management Pack | ||
| ProLiant Essentials Workload Management Pack, Single Server License |
303284-B21
|
|
| NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_na/11452_na.html | ||
| ProLiant Essentials Virtualization Management Software | ||
| ProLiant Essentials
Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
435661-B21 |
|
| ProLiant
Essentials Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. |
435663-B21
|
|
| HP ProLiant Essentials
Server Migration Pack - Physical to ProLiant Edition. 1 Year Unlimited Migration
License |
412982-B21
|
|
| ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition, Single-Migration License |
412978-B21
|
|
| NOTE: For additional ProLiant Essentials Virtualization Management Software License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.html | ||
| ProLiant Essentials Vulnerability and Patch Management Pack | ||
| ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
371645-B21
|
|
| NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_na/12111_na.html | ||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
||
|
|
||
| Remote Management | Integrated Lights-Out Advanced
Pack |
|
| Integrated Lights-Out Advanced
Pack, 1 server Featuring: Sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites. |
263825-B21 | |
| NOTE: For additional Integrated Light-Out Advanced Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11052_na/11052_na.html | ||
|
|
||
| ProLiant Software Maintenance Subscription | ProLiant Software Maintenance Subscription | 355060-B21 |
| ProLiant Software Maintenance Single Release | 356573-B21 | |
| ProLiant Foundation Pack Single Release | 356604-B21 | |
| NOTE:
Please see the SmartStart QuickSpecs for additional information regarding
the subscription purchase: http://h18000.www1.hp.com/products/quickspecs/north_america/11073.html |
||
|
|
||
| Processor | Intel Xeon X3.2-1MB/800MHz Processor Option Kit | 374492-B21 |
| Intel Xeon X2.8-2MB/800MHz Processor Option Kit | 397645-B21 | |
| Intel Xeon X3.0-2MB/800MHz Processor Option Kit | 378748-B21 | |
| Intel Xeon X3.0-2MB/800MHz LV Processor Option Kit | 397646-B21 | |
| Intel Xeon X3.2-2MB/800MHz Processor Option Kit | 378749-B21 | |
| Intel Xeon X3.4-2MB/800MHz Processor Option Kit | 378750-B21 | |
| Intel Xeon X3.6-2MB/800MHz Processor Option Kit | 378751-B21 | |
| Intel Xeon X3.8-2MB/800MHz Processor Option Kit | 378752-B21 | |
|
|
||
|
Memory |
1 GB of Advanced PC2 PC3200 DDR2
SDRAM DIMM Memory Kit (2 x 512 MB) |
343055-B21
|
| 2 GB of Advanced PC2 PC3200 DDR2
SDRAM DIMM Memory Kit (2 x 1024 MB) |
343056-B21
|
|
| 4 GB of Single-Ranked PC2 PC3200
DDR2 SDRAM DIMM Memory Kit (2 x 2048 MB) |
343057-B21
|
|
| 4 GB of 2-Rank Advanced ECC PC3200
DDR2-400 SDRAM DIMM Memory Kit (2 x 2048 MB) NOTE: There are configuration limitations associated with this kit, please see memory section for more information. |
375004-B21
|
|
|
|
||
| Optical Drives | Slimline CD-RW/DVD-ROM Combo Option Kit |
331903-B21
|
| Slimline DVD-ROM Drive (8x/24x)
Option Kit NOTE: Included in high performance models. |
264007-B21 | |
| HP DVD+R/RW 8X Slim | 383975-B21 | |
|
|
||
| Diskette Drive | Floppy Drive Option Kit NOTE: For U320 SCSI models only. NOTE: Included in high performance models. |
364507-B21 |
| Floppy Drive Option Kit, SAS NOTE: For SAS models only. |
393998-B21 |
|
|
|
||
| Hard Drives | Ultra320 SCSI - Universal Hot Plug | |
| HP 300GB U320 10K Universal HDD |
350964-B22
|
|
| HP 146GB U320 10K Universal HDD |
286716-B22
|
|
| HP 72GB U320 10K Universal HDD |
286714-B22
|
|
| HP 300GB U320 15K Universal HDD |
411089-B22
|
|
| HP 146GB U320 15K Universal HDD |
347708-B22
|
|
| HP 72GB U320 15K Universal HDD |
286778-B22
|
|
| HP 36GB U320 15K Universal HDD |
286776-B22
|
|
| NOTE: All U320
Universal Hard Drives are backward compatible to U2 or U3 speeds. NOTE: Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html |
||
| SFF SATA Hot Plug | ||
| HP 60GB 1.5G SATA 5.4K SFF HDD |
379306-B21
|
|
| NOTE: SATA drives
have a 1 year warranty. Please see the SATA Hard Drive QuickSpecs for Technical
Specifications such as capacity, height, width, interface, transfer rate,
seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/12091_na/12091_na.html |
||
| SAS Hot Plug | ||
| HP 146GB 3G SAS 10K SFF SP HDD |
431958-B21
|
|
| HP 72GB 3G SAS 10K SFF SP HDD
|
375861-B21
|
|
| HP 72GB 3G SAS 15K SFF SP HDD |
431935-B21
|
|
| HP 36GB 3G SAS 10K SFF SP HDD |
375859-B21
|
|
| HP 36GB 3G SAS 15K SFF SP HDD |
431933-B21
|
|
| NOTE: All SAS
Universal Hard Drives are supported ONLY by HP ProLiant DL380 G4 SAS models.
NOTE: Please see the SAS Hard Drive QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html |
||
|
|
||
| SCSI Configuration Kit | SCSI Configuration Kit NOTE: Kit Includes duplex drive backplane terminator and 2 long SCSI cables. Not supported on SAS models. |
364471-B21
|
|
|
||
| Storage Controllers | NOTE: Please refer
to the HP ProLiant DL380 G4 SCSI Cabling Matrix for information on what's
required to cable optional array controllers: ftp://ftp.compaq.com/pub/products/servers/proliantdl380/dl380g4-cabling-matrix.pdf |
|
| SCSI Controllers |
||
| 128MB Battery-Backed Write Cache
with Battery Housing NOTE: For Smart Array 6i Controller. Included in high performance models. |
346914-B21
|
|
| Smart Array 6402/128 Controller |
273915-B21
|
|
| Smart Array 6404/256 Controller |
273914-B21
|
|
| Smart Array 641 Controller NOTE: Not supported on SAS model. |
291966-B21
|
|
| Smart Array 642 Controller |
291967-B21
|
|
| 128-MB BBWC (Battery-Backed Write
Cache) Enabler NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller. |
351580-B21
|
|
| Ultra320 Expansion Module for SA-6402 |
273911-B21
|
|
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
|
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12030_na/12030_na.html (Smart Array 6i) http://h18000.www1.hp.com/products/quickspecs/11587_na/11587_na.html (Smart Array 6400 Series) http://h18000.www1.hp.com/products/quickspecs/12067_na/12067_na.html (Smart Array 641) http://h18000.www1.hp.com/products/quickspecs/12069_na/12069_na.html (Smart Array 642) http://h18000.www1.hp.com/products/quickspecs/11943_na/11943_na.html (Single Channel U320 SCSI G2 HBA) |
||
| SAS Controller |
||
| Smart Array P600 Controller | ||
| HP
Smart Array P600/256 BBWC Controller NOTE: Ships standard on SAS models. |
337972-B21
|
|
| 512MB
DDR BBWC Upgrade |
372538-B21
|
|
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12247_na/12247_na.html (Smart Array P600 Controller) |
||
| SAS HBA |
||
| HP SC44Ge Host Bus Adapter |
416096-B21
|
|
| HP 8 Internal Port SAS HBA with RAID |
347786-B21
|
|
|
NOTE: Please see the following QuickSpecs for additional information:
|
||
|
|
||
| Communications | HP NC110T PCI Express Gigabit
Server Adapter |
434905-B21
|
| HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter |
367132-B21
|
|
| HP NC310F PCI-X 1000SX Gigabit Server Adapter |
368169-B21
|
|
| HP NC340T PCI-X 4-port 1000T Gigabit Server Adapter |
391661-B21
|
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC373F PCI Express Multifunction
Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction
Gigabit Server Adapter |
394791-B21
|
|
| HP NC380T PCI Express Dual Port
Multifunction Gigabit Server Adapter |
394795-B21
|
|
| HP NC510F PCIe 10 Gigabit Server
Adapter NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510F adapter. |
414126-B21
|
|
| HP NC510C PCIe 10 Gigabit Server
Adapter NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510C adapter. |
414129-B21
|
|
| HP NC7771 PCI-X 1000T Gigabit Server Adapter |
290563-B21
|
|
| HP IB 4X SDR PCI-e single PORT HCA |
431038-B21
|
|
| HP IB 4X DDR PCI-e Single PORT HCA |
431039-B21
|
|
|
|
||
|
Redundant Options |
Hot Plug AC Redundant Power Supply Module (NEMA and IEC cord) |
355892-001
|
| Hot Plug AC Redundant Power Supply Module (IEC cord only) |
355892-B21
|
|
| Redundant Fan Option Kit NOTE: Hot Plug Redundant Fan Option Kit (PN 293048-B21) contains three fans per kit, it is included in all 2MB Cache, SAS and high performance models. |
293048-B21
|
|
|
|
||
|
Management Options |
Remote Insight Lights-Out Edition II |
227251-001
|
|
|
||
|
Tape Drives |
| ||||||||||||||||||||||||||||||
| | |||||||||||||||||||||||||||||||
| Tape Autoloaders |
HP StorageWorks DAT Autoloader | |
| HP StorageWorks DAT 72x10 tape autoloader | AE313A | |
| HP StorageWorks 1/8 Tape Autoloader | ||
| HP StorageWorks 1/8 Ultrium 920
G2 Tape Autoloader |
AH165A | |
| HP StorageWorks 1/8 Ultrium 448
G2 Tape Autoloader |
AH164A | |
| HP StorageWorks 1/8 Ultrium 232
G2 Tape Autoloader |
AH163A | |
| HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions |
AH166A | |
| NOTE: Please reference the Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
|
|
||
| Tape Libraries | HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 Ultrium
960 Drive Library |
AG115A | |
| HP StorageWorks MSL2024 1 Ultrium
960 4GB FC Drive Library |
AG326B | |
| HP StorageWorks MSL2024 1 Ultrium
920 Drive Library |
AH169A | |
| HP StorageWorks MSL2024 2 Ultrium
920 Drive Library |
AH170A | |
| HP StorageWorks MSL2024 1 Ultrium 448 Drive Library | AG116A | |
| HP StorageWorks MSL2024 2 Ultrium 448 Drive Library | AG117A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 1 Ultrium 448 Drive Library | AG320A | |
| HP StorageWorks MSL4048 2 Ultrium
448 Drive Library |
AG321A | |
| HP StorageWorks MSL4048 1 Ultrium
920 Drive Library |
AH171A | |
| HP StorageWorks MSL4048 2 Ultrium
920 Drive Library |
AH172A | |
| HP StorageWorks MSL4048 1 Ultrium
960 Drive Library |
AG322A | |
| HP StorageWorks MSL4048 1 Ultrium
960 4GB FC Drive Library |
AG324B | |
| HP StorageWorks MSL4048 2 Ultrium
960 Drive Library |
AG323A | |
| HP StorageWorks MSL4048 2 Ultrium 960 4GB FC Drive Library | AG325B | |
| HP StorageWorks MSL6000 Tape Library | ||
| Ultrium 960 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library | AD606B | |
| HP StorageWorks MSL6030 1 Ultrium 960 Dr FC Library | AD608B | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library | AD607B | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library | AD609B | |
| Ultrium 460 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 460 Dr LVDS Library | AD598B | |
| HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library | AD600B | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library | AD599B | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library | AD601B | |
| NOTE: Please reference the MSL2024, MSL4048 and MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
|
|
||
| HP Data Protector Express Software | HP DP Express Backup Server Upgrade for ProLiant Software | BB117AP |
| HP DP Express Package for Microsoft Small Business Server | BB118AA | |
NOTE: Please
see the HP Data Protector Express QuickSpecs for additional information regarding
the purchase of HP Data Protector Express software: NOTE: To obtain a free licensed copy of HP Data Protector Express for ProLiant edition software, please visit the "Protect Your Data" link accessible from your ProLiant server's System Management Homepage (SMH) software (SmartStart 7.5 or later). | ||
| | ||
| Cluster Options | ProLiant Cluster Starter Kit |
364023-B22
|
| NOTE: For additional
information regarding the ProLiant Cluster Starter Kit please see the following
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html |
||
| ProLiant Cluster HA/F200 for the Entry Level SAN |
364026-B22 |
|
| NOTE: For additional
information regarding the ProLiant Cluster for Entry Level SAN please see
the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html |
||
| ProLiant Cluster HA/F500 for the Enterprise SAN |
364024-B21
|
|
| NOTE: For additional
information regarding the ProLiant Cluster HA/F500 for Enterprise SAN please
see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11933_na/11933_na.html |
||
| NOTE: For configuration/certification options for the HP Parallel Database Cluster for Oracle RAC please go to: http://www.hp.com/solutions/highavailability/oracle | ||
| HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 (2 node license cluster kit) |
305199-B26
|
|
| HP Serviceguard for Linux A.11.16
for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 (single license version)
|
307754-B26
|
|
| HP Serviceguard for Linux and
Red Hat Global File System - 1 year subscription |
T2798AA#001
|
|
| HP Serviceguard for Linux and Red Hat Global File System - 3 years subscription |
T2798AA#003
|
|
| NOTE: For additional
information regarding the HP Serviceguard for Linux License, please see
the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html NOTE: For configuration/certification options for HP Serviceguard for Linux please go to: http://www.hp.com/info/sglx |
||
|
|
||
| HP StorageWorks Modular Smart Array 20 | HP StorageWorks Modular Smart
Array 20 NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. |
335921-B21 |
| HP StorageWorks Modular Smart
Array 20 Starter Kit NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller. |
366172-B21 | |
| NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 3.5” Hot Plug Hard Drives. | ||
|
|
||
| HP StorageWorks Modular Smart Array 30 | HP StorageWorks Modular Smart
Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies |
302969-B21 |
| HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies |
302970-B21 | |
| NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 Hot Plug Hard Drives. | ||
|
|
||
|
HP StorageWorks Modular Smart Array 50 |
HP StorageWorks Modular Smart Array 50 Enclosure |
364430-B21
|
| NOTE: Supported
by the SAS Models only. NOTE: Please see the Modular Smart Array 50 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html |
||
|
|
||
|
HP StorageWorks Modular Smart Array 500 G2 |
HP StorageWorks Modular Smart Array 500 Generation 2 |
335880-B21
|
| NOTE:
Please see the Modular Smart Array 500 Generation 2 QuickSpecs for additional
information including configuration steps and additional options needed
for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.html |
||
|
|
||
|
HP StorageWorks Modular Smart Array 1000 |
HP StorageWorks Modular Smart Array 1000 |
201723-B22 |
| NOTE: Please see
the Modular Smart Array 1000 QuickSpecs for additional options and configuration
information at: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html |
||
|
|
||
|
HP StorageWorks Modular Smart Array 1500 cs |
Modular Smart Array 1500 Controller Shelf |
AA986A |
| NOTE: Please see
the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options
and configuration information at: http://www.hp.com/go/MSA1500cs |
||
|
|
||
|
StorageWorks Options |
NOTE: For the complete listing of Fibre Channel Host Bus Adapters for Windows 2000, Windows Server 2003 and Linux, please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html | |
| HP StorageWorks FC2142SR 4Gb PCI-e HBA |
A8002A
|
|
| HP StorageWorks FC2242SR Dual Channel 4 Gb PCI-e HBA |
A8003A
|
|
| HP StorageWorks FC1142SR 4Gb PCI-e HBA |
AE311A
|
|
| HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-e HBA |
AE312A
|
|
| HP StorageWorks FC2143 4Gb PCI-X 2.0 -to-Fibre Channel HBA |
AD167A
|
|
| HP StorageWorks FC2243 Dual Channel 4Gb PCI-X 2.0 HBA |
AD168A
|
|
| HP StorageWorks FC1143 4Gb PCI-X 2.0 HBA |
AB429A
|
|
| HP StorageWorks FC1243 Dual Channel 4Gb PCI-X 2.0 HBA |
AE369A
|
|
|
|
||
|
Uninterruptible Power Systems - Rack |
HP, R1.5kVA UPS, 1U |
AF419A
|
| HP R3000 VA UPS, 2U, L5-30 NOTE: Replaces non-RoHs compliant part number 192186-001. |
AF422A | |
| HP R3000 VA UPS, 2U, L6-20 NOTE: Replaces non-RoHs compliant part number 192186-002. |
AF423A | |
| HP R5500 VA UPS NOTE: Replaces non-RoHs compliant part number 326529-D71. |
AF426A | |
|
|
||
| HP Monitored Power Distribution Unit (PDU) | HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 17.3 kVA S2324 Monitored PDU-
dual input, 3U, 24A NOTE: Replaces non-RoHs compliant part number 370959-D71. |
AF503A
|
|
| HP 8.3 kVA S1324 Monitored PDU-
single input, 3U, 24A NOTE: Replaces non-RoHs compliant part number 370960-D71. |
AF504A
|
|
| HP 16.6 kVA S2140 Monitored PDU-
dual input, 1U, 40A NOTE: Replaces non-RoHs compliant part number 37061-D71. |
AF505A
|
|
| HP 8.6 S1140 Monitored PDU- single
input, 1U, 40A NOTE: Replaces non-RoHs compliant part number 370962-D71. |
AF506A
|
|
|
|
||
| Modular Power
Distribution Units 1U/0U (Up to 32 outlets) NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and 9000 series racks). |
3.6kVA Model - mPDU, 16A, High |
252663-B24
|
| 2.8 kVA Model - mPDU, 24A, Low
|
252663-D71
|
|
| 4.9kVA Model - mPDU, 24A, High |
252663-D72
|
|
| 8.3kVA Model - mPDU, 40A, High |
252663-B21
|
|
| 8.3kVA
Model - mPDU, 40A, High (power cord attached) |
252663-D73
|
|
| 8.3kVA Model - mPDU 40A, High
(core only) |
252663-D75
|
|
| 4.9kVA Model - mPDU 24A, High (core only) |
252663-D74
|
|
| NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html |
||
|
|
||
| USB Options | HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) |
DC172B
|
||
| HP USB 04 Standard Keyboard |
DT528A#ABA
|
|||
| USB 2.0 4-port HUB |
DG954A
|
|||
| HP 1GB Drive Key II- USB 2.0 Flash Drive |
AG382AA
|
|||
| HP 512MB DriveKey II- USB Flash Drive |
ED516AA
|
|||
|
|
||||
| Rack Shipping Kit | Shipping Bracket for Round Hole
Racks NOTE: Required when shipping server pre-installed in round hole rack. Square hole pre-configured rack shipping hardware included with server mounting rails. |
371482-B21 |
|
|
||
| HP Rack 5000 Series (Graphite Metallic) | HP 5642 Rack-Unassembled |
358254-B21
|
| NOTE:
Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical
Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
||
|
|
||
|
HP Rack 10000 G2 Series (Carbon/ Graphite Metallic) |
10642 G2 (42U) Rack Cabinet - Pallet |
AF001A
|
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A
|
|
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A
|
|
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet |
AF004A
|
|
| 10636 G2 (36U) Rack Cabinet - Pallet |
AF011A
|
|
| 10636 G2 (36U) Rack Cabinet - Shock Pallet |
AF012A
|
|
| 10636 G2 (36U) Rack Cabinet - Crated |
AF013A
|
|
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet |
AF014A
|
|
| 10622 G2 (22U) Rack Cabinet -
Pallet |
AF021A
|
|
| 10622 G2 (22U) Rack Cabinet -
Shock Pallet |
AF022A
|
|
| 10842 G2 (42U) 800mm Wide Rack
Cabinet - Pallet |
AF041A
|
|
| 10842 G2 (42U) 800mm Wide Rack
Cabinet - Shock Pallet |
AF042A
|
|
| 10647 G2 (47U) Rack Cabinet - Pallet |
AF031A
|
|
| NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. | ||
| NOTE: Please see
the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
| HP Rack 10000
Series (Graphite Metallic) |
10642 (42U) Infrastructure Rack (Low Voltage) |
379006-001
|
| 10642 (42U) Infrastructure Rack (High Voltage) |
379005-001
|
|
| HP S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22
|
|
| HP 10842 (42U) Rack Cabinet - Pallet |
257415-B21
|
|
| HP 10842 (42U) Rack Cabinet - Shock Pallet |
257415-B22
|
|
| HP 10647 (47U) Rack Cabinet - Pallet |
245160-B21
|
|
| HP 10647 (47U) Rack Cabinet - Crated |
245160-B23
|
|
| HP 10622 (22U) Rack Cabinet - Pallet |
245163-B21
|
|
| HP 10622 (22U) Rack Cabinet - Shock Pallet |
245163-B22
|
|
| HP 10622 (22U) Rack Cabinet - Crated |
245163-B23
|
|
| NOTE: xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). xxxxxx-B23 (crated) used for air shipments of empty racks. | ||
| NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. | ||
| NOTE: Please see
the Rack 10000 QuickSpecs for additional options and Technical Specifications
such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower | ||
|
|
||
| Keyboards and Monitors | TFT7210R Rack Mounted 17"
Monitor |
348373-B21 |
| TFT7600 Rackmount Keyboard Monitor | AG052A | |
| 1U Rackmount Keyboard with USB | AG072A | |
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower | ||
|
|
||
| HP KVM Switch Options | 2x1x16 IP Console Switch with Virtual Media |
AF601A
|
| 4x1x16 IP Console Switch with Virtual Media | AF602A | |
| 2x16 Server Console Switch with Virtual Media | AF600A | |
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A | |
| Server Console Switch (KVM), 0 x 1 x 8 port |
336044-B21
|
|
| Server Console Switch (KVM), 0 x 2 x 16 port |
336045-B21
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| USB Interface Adapter, 1 pack |
336047-B21
|
|
| Serial Interface adapter - 1 Pack with power supply |
373035-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x 4 USB/PS2 KVM Switch, TT |
371301-D71
|
|
| HP 1x 4 USB/PS2 KVM Switch, RM |
371302-B21
|
|
| HP PS2 KVM Cable with audio, 6', 2-pack |
371730-B21
|
|
| HP USB KVM Cable with audio, 6', 2-pack |
371729-B21
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| HP Serial Console Server Options | HP 16 Port Serial Console Server |
AF101A
|
||
| HP 48 Port Serial Console Server |
AF102A
|
|||
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A
|
|||
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A
|
|||
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||||
|
|
||||
| Service and Support Offerings (HP Care Pack Services) |
|
||||||||||
|
|||||||||||
|
|||||||||||
|
|||||||||||
|
|
|
Memory
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| HP ProLiant Model DL380 Generation 4 (G4) Base (1P) Models |
| Standard
Memory 1 GB PC2 3200 DDR2 SDRAM running at 400MHz comes installed (2 x 512 MB SDRAM) Standard Memory Plus Optional Memory Up to 9 GB memory is available with the optional installation of PC2 3200 Registered DDR2 SDRAM DIMM Memory Option Kit Standard Memory Replaced with Optional Memory Up to 12 GB of memory is available with the removal of the standard 512 MB of memory and the optional installation of PC2 3200 Registered DDR2 SDRAM DIMM Memory Option Kit NOTE: Chart does not represent all possible memory configurations. |
|
Memory
|
Slot
|
||||||
|
1
|
2
|
3
|
4
|
5
|
6
|
||
| Standard |
1 GB
|
512 MB
|
512 MB
|
Empty
|
Empty
|
Empty
|
Empty
|
| Optional |
9 GB
|
512 MB
|
512 MB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
|
Maximum |
12 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
| NOTE: In the online spare configuration, the ROM automatically configures the last populated bank as the spare memory. If only banks A and B are populated, bank B is the spare bank. If banks A, B, and C are populated, bank C is the spare bank, Online spare memory is configured through RBSU. | |
|
Following are the single-rank memory options available from HP: |
|
|
343055-B21 |
|
343056-B21 |
|
343057-B21 |
|
375004-B21 |
|
|
|
|
HP ProLiant Model DL380 Generation 4 (G4) High Performance (2P) Model |
|
Standard Memory Standard Memory Plus Optional Memory Standard Memory Replaced with Optional Memory NOTE: Chart does not represent all possible memory configurations. |
|
Memory |
Slot | ||||||
|
1 | 2 |
3 | 4 |
5 | 6 | ||
| Standard |
2 GB | 1024
MB | 1024
MB | Empty |
Empty | Empty |
Empty |
| Optional |
10 GB | 1024
MB | 1024
MB | 2 GB |
2 GB | 2
GB | 2 GB |
| Maximum |
12 GB | 2
GB | 2 GB |
2 GB | 2
GB | 2 GB |
2 GB |
| NOTE: In the online spare configuration, the ROM automatically configures the last populated bank as the spare memory. If only banks A and B are populated, bank B is the spare bank. If banks A, B, and C are populated, bank C is the spare bank, Online spare memory is configured through RBSU. | |
|
Following are the single rank memory options available from HP: |
|
|
343055-B21 |
|
343056-B21 |
|
343057-B21 |
|
|
|
| HP ProLiant Model DL380 Generation 4 (G4) Dual Rank Support: | |||
|
Following is the dual rank memory option available from HP: | |||
| 375004-B21 | ||
| Following are the single/dual rank memory population rules for the HP ProLiant DL380 G4. | |||
| Key: S denotes single rank kit, D denotes Dual rank kit, and X denotes no install. | |||
|
Bank A |
Bank B |
Bank C |
NOTES: |
|
S | X |
X |
|
|
S | S |
X |
|
|
S | S |
S | |
| D |
X | X |
Online spare not supported |
|
D | S |
X |
Online spare not supported |
|
D | S |
S |
Online spare not supported |
|
D | D |
X |
Online spare not supported |
|
|
Storage
![]() |
0 - 5
|
Six Ultra320 SCSI hot plug hard drive bays |
|
A
|
1.44-MB Diskette Drive | |
|
B
|
24x IDE CD-ROM (Universal Media Bay) | |
|
C
|
Six Ultra320 SCSI hot plug hard drives or for five hot plug hard drives and one DAT 40 or DAT 72 hot plug tape drive | |
![]() |
1-8
|
Eight SFF SAS hot plug hard drive bays |
|
Drive Support |
|||
|
|
|||
|
Quantity |
Position |
|
|
|
Removable Media |
|||
| 1.44-MB Diskette Drive | 1 | A | Integrated IDE NOTE: Optional except on high performance models |
| IDE CD-ROM Drive | 1 | B | Integrated IDE NOTE: Standard on base models |
| Slimline DVD-ROM (8x24x) Option Kit (Servers) | 1 | B | Integrated IDE NOTE: Standard on high performance models |
|
|
|||
|
Hard Drives | |||
| Ultra320 SCSI - Hot Plug Drives | |||
| Quantity |
Position |
| |
|
300GB U320 10K | Up to 6 | 0-5 |
Smart Array 6i Controller (integrated on system board) Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 641 Controller Smart Array 642 Controller |
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. | |||
| | |||
| SFF SATA - Hot Plug Drives | |||
|
Quantity |
Position |
| |
|
60GB 1.5G SATA 5.4K | Up to 8 | 0-7 | Smart Array P600/256 BBWC Controller |
|
| |||
| SFF SAS - Hot Plug Drives | |||
|
Quantity |
Position |
| |
|
146GB 3G SAS 10K SP | Up to 8 | 1-8 | Smart Array P600/256 BBWC Controller |
|
| |||
|
External Storage | ||||
| Quantity |
Position |
| ||
| Modular Smart Array 20 | 1 per SCSI VHDCI connector | External | Smart
Array 6i Controller Smart Array 6402/128 Controller Smart Array 6404/256 Controller | |
|
Modular Smart Array 30 |
1 per SCSI VHDCI connector |
External | Smart Array 6i
Controller Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller | |
| Modular Smart Array 50 Enclosure | 2 per connector (supports 1+1 cascading) | External | HP Smart Array P600/256 BBWC Controller | |
| Modular
Smart Array 500 G2 | 1 per SCSI | External | Smart
Array 6i Controller Smart Array 642 Controller (used as Host Bus Adapter) Please see the Modular Smart Array 500 G2 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/msa500 | |
| Modular
Smart Array 1500 cs | Please see the Modular Smart Array 1500 cs QuickSpecs link below to determine configuration requirements | External | Please see the Modular Smart Array 1500 QuickSpecs (URL below) for the latest list of supported HBAs | |
| Modular Smart Array 1000 | Please see the Modular Smart Array 1000 QuickSpecs link below to determine configuration requirements | External | Please see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of supported HBAs | |
| Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html
Modular Smart Array 1500: http://www.hp.com/go/MSA1500cs |
||||
| | ||||
|
Maximum Storage Capacity - (Enclosure SCSI Attached) | |
| Internal |
1.80TB (6 x 300GB Ultra320) |
| External | 54.60TB (13 x (14 x 300GB Ultra320)) |
| Total | 58.20TB |
| | |
|
Maximum Storage Capacity - (SAS Models with MSA50) |
|
|
Internal |
1.168TB (8 x 146GB SAS) |
| External | 2.920 (20 x 146GB SAS) |
| Total | 4.088TB |
|
|
|
| Tape Drives, Tape Autoloaders, & Tape Libraries | ||||
|
NOTE: For an up-to-date listing of the
latest O/S Support details for each of the Tape Drives listed below, please
see the following: For recommended tape drive offerings for this ProLiant server see the following: |
||||
|
Position
Supported |
Controller
|
Controller Part Number
|
||
| HP StorageWorks Tape Drives,
External DAT 24 USB DAT 40 USB DAT 72 USB |
External
|
USB 2.0 Port
|
N/A
|
|
| HP StorageWorks Tape Drives,
External Ultrium 232 Ultrium 448 Ultrium 460 Ultrium 920 Ultrium 960 DAT 40 DAT 72 DLT VS160 SDLT 600 |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
|
374654-B21
|
|
| HP StorageWorks Autoloaders,
External DAT 72x10 Autoloader 1/8 G2 Tape Autoloader |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
|
374654-B21
|
|
|
HP StorageWorks SCSI Rack-Mount Tape Drive Enclosures |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
|
374654-B21
|
|
| HP StorageWorks USB Rack-Mount
Tape Drive Enclosures 1U Rack-Mount Kit |
External
|
USB 2.0 Port
|
N/A
|
|
| HP StorageWorks Tape Libraries,
External MSL2024 (Ultrium 448, Ultrium 920 and 960-based) MSL4048 (Ultrium 448, Ultrium 920 and 960-based) MSL6000 (Ultrium 960 and 460-based) MSL6000 (SDLT 600-based) |
External |
Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs
for detailed connectivity information
|
N/A
|
|
|
|
Power Specifications
| Power Supply Specification |
Part number
|
321632-001
|
||||
|
Spare Kit
|
355892-B21
|
|||||
| Operational Input Voltage Range (Vrms) |
90 - 264
|
|||||
| Frequency Range (Nominal) (Hz) |
47 - 63 ( 50 / 60 )
|
|||||
| Nominal Input Voltage (Vrms) |
100
|
115
|
208
|
220
|
230
|
240
|
| Max Rated Output Wattage Rating |
575
|
575
|
575
|
575
|
575
|
575
|
| Nominal Input Current (A rms) |
7.4
|
6.4
|
3.4
|
3.2
|
3.1
|
2.9
|
| Max Rated Input Wattage Rating (Watts) |
728
|
719
|
701
|
693
|
693
|
693
|
| Max. Rated VA (Volt-Amp) |
743
|
733
|
716
|
707
|
707
|
707
|
| Efficiency (%) |
79
|
80
|
82
|
83
|
83
|
83
|
| Power Factor |
0.98
|
|||||
| Leakage Current (mA) |
0.31
|
0.36
|
0.65
|
0.69
|
0.72
|
0.75
|
| Max. Inrush Current (A peak) |
35
|
35
|
35
|
35
|
35
|
35
|
| Max. Inrush Current duration (mS) |
2-3
|
|||||
| Power cord requirements | Nema 5-15P to IEC320-C13 Option no. / Spare no: See chart on Page 2 | |||||
| IEC320-C13 to IEC320-C14 Option no. / Spare no.: 142259-001/142258-B21 | ||||||
|
NOTES:
|
| # - Power cords (13 Cord Sets) |
Power Cord Part Number
|
|
163719-002
|
|
|
Technical Specifications
| System Unit | Dimensions
(HxWxD) (with feet/bezel) | 3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm) | |
| Weight(approximate) | Maximum | 60 lb (27.22 kg) | |
| No drives: | 47.18 lb (20.41 kg) | ||
| Input Requirements (per power supply) | Rated Input Voltage | 100-132 VAC, 200-240 VAC | |
| Rated Input Current | 7.5A (100VAC), 3.8A (200VAC) | ||
| Rated Input Frequency | 50 to 60 Hz | ||
| Rated Input Power | 735 W | ||
| BTU Rating | 2508 BTU/HR | ||
| Power Specifications | To
review typical system power ratings use the Active Answers Power Calculator which
is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/powercalcs.asp. To drill down to calculators: - Click on: "ProLiant Servers" - Click on the Server of interest. Example: DL380 G4 - Click on: "Power Calculator" link. (You may need to scroll down to see it.) | ||
| SCSI Connectors | One external VHDCI
connector NOTE: External VHDCI not included on SAS Models |
||
| Power
Supply Output Power (per power supply) | Rated Steady-State Power | 575W | |
| Maximum Peak Power | 575W | ||
| Temperature Range NOTE: All temperature ratings shown are for sea level. An altitude derating of 1 C° per 300 m (1.8 FR per 1000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. | Operating | 50° to 95° F (10° to 35° C) | |
| Shipping | -40° to 158° F (-40° to 70° C) | ||
| Maximum Wet Bulb Temperature | 82.4° F (28° C) | ||
| Relative
Humidity (non-condensing) NOTE: Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 kPa. | Operating | 10% to 90% | |
| Shipping | 5% to 95% | ||
| Acoustic Noise | Idle Minimum (Fixed Disk Drives Spinning) | ||
| L
WAd (BELS) | 7.4 | ||
| L
pAm (dBA) | 58 | ||
| Operating Minimum
(Random Seeks to Fixed Disks) | |||
| L
WAd (BELS) | 7.4 | ||
| L
pAm (dBA) | 58 | ||
| | |||
| Smart Array 6i Controller (Ultra320), Integrated | Data Compatible with all Smart Array Controllers | Yes |
| Instant Upgrades to other Smart Array Controllers | Yes | |
| Consistent Software Manageability Tools | Yes | |
| PCI-X Bus | 64-bit up to 133 MHz (integrated on system board) | |
| Electrical Protocol | Low Voltage Differential (LVD) | |
| SCSI Protocols Supported | Ultra 320, Ultra3, Ultra2 | |
| SCSI Peak Data Transfer Rate |
320 MB/s per channel | |
| Channels | Two 68-Pin Wide-Ultra SCSI-3 connectors | |
| SCSI Ports (external/internal) |
1/2 NOTE: The HP ProLiant DL380 G4 external SCSI port can only be used if PORT 1 of the system board is NOT connected to the internal SCSI backplane. |
|
| Logical Drives Supported |
Supports up to 32 RAID volume | |
| Cache | 64 MB Read Cache | |
| Battery-Backed Write Cache | Yes, with installation of Battery-Backed Write Cache Enabler, up to 128MB | |
| RAID Support | 0, 1, 1+0, 5 | |
| Online Configuration | Yes | |
| Online Capacity Expansion | Yes | |
| Logical Drive Capacity Extension | Yes | |
| Online Stripe Size Migration | Yes | |
| Online RAID Level Migration | Yes | |
| Online Spare Support | Yes | |
| Automatic Data Recovery | Yes | |
| Drive Roaming | Yes | |
| Redundant Controllers | No | |
|
|
||
| Smart Array P600
Controller (SAS models only) |
Disk Drive and Enclosure Protocol
Support |
3 Gbps SAS (Serial Attached SCSI) 1.5 Gbps SATA (Serial AT Attachment) |
| Architecture |
1.5 Gb SATA | |
| SAS Connectors |
1 internal SFF8484 & 1 external
SFF8470 / internal SFF8484 shared x4 Wide SAS Ports 12 Gbps per x4 Wide SAS Port (4 x 3 Gbps) |
|
| Data Transfer Method |
64-bit wide, PCIX 133 MHz (1 GB/s maximum bandwidth) | |
| PCI Bus Speed |
PCIX-133 and 3.3 volt PCI compatibility only | |
| Memory Bus Speed | DDR-266 and 72 bit wide bus | |
| PCI |
64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth) | |
| Simultaneous Drive Transfer Ports | PCI-X and 3.3 volt PCI compatibility only | |
| Port Transfer Rate | 2 x4 Wide SAS Ports | |
| Software upgradeable Firmware |
12 Gb/s per x4 Wide SAS Port (4 x 3 Gb/s) | |
| Cache Memory |
Yes | |
| Logical Drives Supported |
256 MB Read/Write (512-MB module
upgrade available); ECC protection, battery-backed, and removable |
|
| Maximum Capacity |
Up to 32 logical drives Up to 2.2 TB per logical drive |
|
| Memory Addressing |
2.7 TB (38 x 72 GB) 64-bit, supporting servers memory greater than 4 GB |
|
| RAID Support | RAID 6 (Advanced Data Guarding) RAID 5 (Distributed Data Guarding) RAID 1+0 (Striping & Mirroring) RAID 0 (Striping) |
|
| Upgradeable Firmware Disk Drive and |
4-MB flashable ROM | |
| Enclosure Protocol Support | 3 Gb SAS and 1.5 Gb SATA | |
|
|
||
| Embedded NC7782 PCI-X Gigabit Server Adapter |
Network Interface | 10Base-T/100Base-TX/1000Base-TX | |
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| Data Transfer Method | 64-bit bus-master PCI-X | ||
| Network Transfer Rate | 10Base-T (Half-Duplex), | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000 Mb/s | ||
| Connector | Two RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) |
|
| 100Base-TX | Category 5 or higher UTP; up to 328 ft (100 m) |
||
| 1000BaseTX | Category 5 or higher UTP; up to 328 ft (100 m) |
||
|
|
|||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for
HP products and services are set forth in the express warranty statements accompanying
such products and services. Nothing herein should be construed as constituting
an additional warranty. HP shall not be liable for technical or editorial errors
or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |