Overview
|
HP ProLiant DL360 Generation 4p (G4p)
|
||||||||||||||||||||||||||||||
What's New
|
| |
| At A Glance
Combining concentrated 1U compute power, integrated
Lights-Out management, and essential fault tolerance, the DL360 is optimized
for space constrained installations. Dual Xeon processors, DDR2 SDRAM,
and PCI-X and PCI Express technology provide a high performance system
ideal for the full range of scale out applications. What's more, the DL360
G4p steps up the fault tolerant in an ultra dense platform with redundant
power, redundant fans, and online spare memory, embedded RAID capability,
and full-featured remote Lights-Out\ management.
|
|
|
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor One of the following depending on Model |
Intel Xeon Processor 2.8 GHz/800MHz -2MB L2, 110W |
| Intel Xeon Processor 3.0 GHz/800MHz -2MB L2, 110W | |
| Intel Xeon Processor 3.0 GHz/800MHz -2MB L2, Low Voltage 55W | |
| Intel Xeon Processor 3.2 GHz/800MHz -2MB L2, 110W | |
| Intel Xeon Processor 3.4 GHz/800MHz -2MB L2, 110W | |
| Intel Xeon Processor 3.6 GHz/800MHz -2MB L2, 110W | |
| Intel Xeon Processor 3.8 GHz/800MHz -2MB L2, 110W | |
| Dual-core Intel Xeon Processor
2.8 GHz/800MHz - 2x2MB L2, 135W NOTE: Dual-core processor is supported on HP ProLiant DL360 G4p Serial Attached SCSI (SAS) models only. |
|
|
| |
| Processor Cache | 2MB Level 2 cache memory |
|
|
|
| Upgradeability | Upgradeable to dual processing |
|
|
|
| Chipset | Intel chipset is E7520 |
| | |
| Memory Protection & Functionality | Advanced ECC (multi-bit error protection) |
| Online spare | |
| 2-way interleaving | |
|
|
|
| Memory | Type | PC2-3200 DDR2 400 SDRAM |
| Standard | 1 GB (2 x 512 MB) | |
| Standard (on some models) | 2 GB (2 x 1024 MB) | |
| Maximum | 12 GB | |
|
|
||
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter |
|
|
|
| Expansion Slots | Slot Number |
Bus Speed | Bus Number* | Device Number** | Hot Plug | PCI Voltage |
|
1
|
64-bit/133MHz PCI-X |
7
|
0
|
no
|
3.3 Volt
|
|
|
1
|
x8 PCI Express (option) |
3
|
0
|
no
|
n/a
|
|
|
2
|
64-bit/133MHz PCI-X |
10
|
0
|
no
|
3.3 Volt
|
|
|
2
|
x8 PCI Express (option) |
13
|
0
|
no
|
n/a
|
|
| *NOTE:
Default bus assignment. Inserting cards with PCI bridges may alter the actual
bus assignment number. **NOTE: Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID by bus (starting with the lowest bus). NOTE: All slots can accept universal keyed PCI cards. |
|
|||||
| Manageability |
Integrated Lights-Out (iLO) Management (integrated on motherboard) |
|
|
|
| Storage Controllers | SAS Models |
HP Smart Array P600/256 BBWC
Controller (installed in PCI-X slot) NOTE: The Smart Array P600 controller offers an external 4X SAS port for additional storage expansion. |
| SCSI Models | HP Smart Array 6i Controller
(embedded) NOTE: The HP ProLiant DL360 G4p does not offer an external SCSI port. |
|
| SATA Models | HP embedded 2 Port SATA Controller
(integrated on system board) NOTE: The HP embedded 2 Port SATA controller does not support RAID, hot plug drive functionality or drive activity LEDs. NOTE: SATA RAID 0, 1 is available with the optional purchase of the HP 8-port SAS HBA (347786-B21) and HP SAS/SATA Cable Kit (398307-B21) - hot-plug drive functionality and drive activity LEDS not supported. |
|
|
|
||
| Storage | Optical Drives | Ejectable CD-ROM
(Standard in most models), DVD-ROM, or DVD-RW drives, or Slimline floppy NOTE: Slimline Floppy Diskette Drive is not supported in SCSI and SATA models. |
|
| Diskette Drive |
1.44 MB Diskette
Drive NOTE: Standard in SCSI models; optional in SATA models; not available in SAS models. |
||
| Drive Bays | SAS Model | 4 Small Form Factor | |
| SCSI Model | 2 HP Universal SCSI | ||
| SATA Model | 2 Pluggable SATA | ||
|
|
|||
| Maximum Internal Storage Type | SAS Model | 584GB SAS | 4 x 146GB SAS |
| 240GB SATA | 4 x 60GB Serial ATA | ||
| SCSI Model | 600GB | 2 x 300GB Ultra320 SCSI | |
| SATA Model | 1.50TB | 2 x 750GB Serial ATA | |
|
|
|||
| Interfaces | Serial | 1 |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Hot Plug Keyboard | 1 | |
| USB Ports | 3 (rear, front, internal) NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
| Network RJ-45 | 2 | |
| iLO remote management port | 1 | |
|
|
||
| Graphics | Integrated ATI RAGE XL Video Controller with 8-MB SDRAM Video Memory |
|
|
|
| Form Factor | Rack (1U), (1.75 in/4.45 cm) |
|
|
|
| ProLiant Essentials Foundation Pack Software |
| ||||||||||||||||||
| | |||||||||||||||||||
| Industry Standard Compliance | ACPI 1.0b Compliant |
| PCI 2.2 Compliant | |
| Microsoft® Logo certifications | |
| USB 1.1 and 2.0 Compliant | |
|
|
|
| Remote Manageability |
Integrated Lights-Out (iLO) Standard Management:
Integrated Lights Out Advanced Pack (optional) |
|
|
|
| Intelligent Manageability |
HP Systems Insight Manager SmartStart Remote Insight Lights-Out Edition ll (optional) ROM-Based Setup Utility (RBSU) Remote-Flash Redundant ROM Integrated Management Log (IML) Server Health logging Automatic Server Recovery-2 (ASR-2) System Interconnect Status Indicators Dynamic sector repairing and drive parameter tracking (with Smart Array controllers) Hot Spare Boot (NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the system will automatically reboot and use the remaining good processor(s).) Power Down Utility Pre-Failure Warranty (covers processors, as well as SCSI/SAS hard drives and memory) |
|
|
|
| Security | Power-on password Keyboard password Diskette drive control Diskette boot control QuickLock, Network Server Mode Removable CD and Diskette Drive Assembly Serial interface control Administrator's password Disk configuration lock Integrated Lights-Out has 12 customizable user accounts and SSL encryption Integrated Lights-Out can be disabled via a Global Setting |
|
|
|
| Server Power Cords | One Lowline NEMA power cord and One Highline IEC Power cord ships standard in most NA models. Smart Buys include one IEC power cable per power supply. Localized cables included with geographic specific models in other world regions. |
| | |
| UPS Power Cord Matrix | Please see the UPS Power Cord
Matrix for cable descriptions, requirements, and specifications for UPS
units: ftp://ftp.compaq.com/pub/products/servers/proliantstorage/power-protection/powercordmatrix.pdf. |
|
|
|
| Power Supply | SAS Models: |
535W Optional (1+ 1 redundant)
power supply NOTE: PN 389830-B21 contains the optional power supply and an IEC power cable only; purchase if connecting to PDU/UPS that supports IEC cables. PN 389830-001 contains a low line (NEMA) power cord only. |
| SCSI & SATA Models: | 460W Optional (1+ 1 redundant)
power supply NOTE: PN 354587-B21 contains the optional power supply and an IEC power cable only; purchase if connecting to PDU/UPS that supports IEC cables. PN 354587-001 contains a low line (NEMA) power cord only. |
|
|
|
||
| System Fans | 7 fans ship standard; Fan redundancy standard |
|
|
|
| Required Cabling | For required cabling information, refer to the Web site at http://h18000.www1.hp.com/products/servers/proliantdl360/. |
| | |
| OS Support | Microsoft Windows 2000 Server Microsoft Windows Server 2003 Novell NetWare Linux (Red Hat, SuSE, UnitedLinux) Solaris VMware Virtualization Software |
| NOTE: SAS, SCSI
and SATA models may have different OS support. Please see OS Support Matrix. NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix page at: http://www.hp.com/go/supportos. NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html NOTE: For a listing of the latest drivers available for the HP ProLiant DL360, please see: http://h18023.www1.hp.com/support/files/server/us/index.html. NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web site at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html. NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html. |
|
|
|
|
| Rack Airflow Requirements | Rack 10000 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/proliantdl360/index.html. | |
| | |
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
|
|
| HP Enterprise Configurator | The HP eCo-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. |
| | |
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of resellers and service providers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Server Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html HP Care Pack services include coverage for the HP branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. HP services provide continuous care and support expertise with committed response designed to meet your IT and business needs. To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime. Enhanced Care - Minimum recommended service support offer designed to
ensure customers have access to expert assistance, whenever they need
it.
Continuance Care - Recommended service delivering cost-effective support
options designed to extend HP Services committed response and guaranteed
fix times, designed to speed problem identification and resolution.
Total Care - Highest HP Support service level recommend to help increase
IT performance and availability with comprehensive, integrated hardware
and software services
Deployment Services - HP Installation and Start Up services designed
to take time, risk, and worry out of the deployment of ProLiant servers
- and free customers IT support staff to focus on what they do best, their
business.
|
| NOTE: For a
complete listing of service offerings and information visit: http://www.hp.com/services/proliantservices http://www.hp.com/go/proliant/carepack |
|
|
Models
| SAS Models | ||
| DL360R04p X3.0-2MB/800,
1GB SAS 389820-xx1 |
Processor | (1) Intel Xeon Processor 3.0 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 1 GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P600/256 BBWC Controller | |
| Hard Drives | None ship standard; system supports up to four Serial SCSI or Serial ATA drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 535W power supply (redundant power supply optional) | |
| Optical Drive | Slimline CD-ROM Drive | |
| PCI-X Slots | 1 full length and 1 half length
64bit/133 MHz PCI-X slot NOTE: Full length slot is occupied with HP Smart Array P600 Controller and is not available. |
|
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
|
|
||
|
DL360R04p X3.2-2MB/800, 2GB SAS RPS |
Processor | (1) Intel Xeon Processor 3.2 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 2 GB (2 x 1024 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P600/256 BBWC Controller | |
| Hard Drives | None ship standard; system supports up to four Serial SCSI or Serial ATA drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | Two 535W power supplies (1+1 redundant) | |
| Optical Drive | Slimline CD-ROM Drive | |
| PCI-X Slots | 1 full length and 1 half length
64bit/133 MHz PCI-X slot NOTE: Full length slot is occupied with HP Smart Array P600 Controller and is not available. |
|
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
|
|
||
|
DL360R04p X3.4-2MB/800, 2GB SAS RPS |
Processor | (1) Intel Xeon Processor 3.4 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 2 GB (2 x 1024 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P600/256 BBWC Controller | |
| Hard Drives | None ship standard; system supports up to four Serial SCSI or Serial ATA drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | Two 535W power supplies (1+1 redundant) | |
| Optical Drive | Slimline CD-ROM Drive | |
| PCI-X Slots | 1 full length and 1 half length
64bit/133 MHz PCI-X slot NOTE: Full length slot is occupied with HP Smart Array P600 Controller and is not available. |
|
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
|
|
||
|
DL360R04p X3.6-2MB/800, 2GB SAS RPS |
Processor | (1) Intel Xeon Processor 3.6 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 2 GB (2 x 1024 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P600/256 BBWC Controller | |
| Hard Drives | None ship standard; system supports up to four Serial SCSI or Serial ATA drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | Two 535W power supplies (1+1 redundant) | |
| Optical Drive | Slimline CD-ROM Drive | |
| PCI-X Slots | 1 full length and 1 half length
64bit/133 MHz PCI-X slot NOTE: Full length slot is occupied with HP Smart Array P600 Controller and is not available. |
|
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
|
|
||
|
DL360R04p X3.8-2MB/800, 2GB SAS RPS |
Processor | (1) Intel Xeon Processor 3.8 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 2 GB (2 x 1024 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P600/256 BBWC Controller | |
| Hard Drives | None ship standard; system supports up to four Serial SCSI or Serial ATA drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | Two 535W power supplies (1+1 redundant) | |
| Optical Drive | Slimline CD-ROM Drive | |
| PCI-X Slots | 1 full length and 1 half length
64bit/133 MHz PCI-X slot NOTE: Full length slot is occupied with HP Smart Array P600 Controller and is not available. |
|
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
|
|
||
| SCSI Models | ||
| DL360R04p
X3.8-2MB/800, 2GB SCSI, RPS | Processor | (1) Intel Xeon Processor 3.8 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 2 GB (2 x 1 GB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE: The HP ProLiant DL360 G4p does not offer an external SCSI port. | |
| Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE: The HP ProLiant DL360 G4p SCSI models only support U320 Universal Hot Plug drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | Two 460W power supplies | |
| Optical Drive | 24x IDE CD-ROM Drive (Low-profile) | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
|
DL360R04p X3.6-2MB/800, 1GB SCSI | Processor | (1) Intel Xeon Processor 3.6 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 1 GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE: The HP ProLiant DL360 G4p does not offer an external SCSI port. | |
| Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE: The HP ProLiant DL360 G4p SCSI models only support U320 Universal Hot Plug drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 460W power supply (redundant power supply optional) | |
| Optical Drive | 24x IDE CD-ROM Drive (Low-profile) | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
|
DL360R04p X3.6-2MB/800, 2GB SCSI, RPS | Processor | (1) Intel Xeon Processor 3.6 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 2 GB (2 x 1 GB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE: The HP ProLiant DL360 G4p does not offer an external SCSI port. | |
| Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE: The HP ProLiant DL360 G4 SCSI models only support U320 Universal Hot Plug drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | Two 460W power supplies (1+1 redundant) | |
| Optical Drive | 24x IDE CD-ROM Drive (Low-profile) | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
|
DL360R04p X3.4-2MB/800, 2GB SCSI, RPS | Processor | (1) Intel Xeon Processor 3.4 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 2 GB (2 x 1-GB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE: The ProLiant DL360 G4p does not offer an external SCSI port. | |
| Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE: The ProLiant DL360 G4p SCSI models only support U320 Universal Hot Plug drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | Two 460W power supply (1+1 redundant) | |
| Optical Drive | 24x IDE CD-ROM Drive (Low-profile) | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
|
DL360R04p X3.4-2MB/800, 1GB SCSI | Processor | (1) Intel Xeon Processor 3.4 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 1 GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE: The HP ProLiant DL360 G4p does not offer an external SCSI port. | |
| Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE: The HP ProLiant DL360 G4 SCSI models only support U320 Universal Hot Plug drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 460W power supply (redundant power supply optional) | |
| Optical Drive | 24x IDE CD-ROM Drive (Low-profile) | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
|
DL360R04p X3.2-2MB/800, 1GB SCSI | Processor | (1) Intel Xeon Processor 3.2 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 1 GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE: The HP ProLiant DL360 G4p does not offer an external SCSI port. | |
| Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE: The HP ProLiant DL360 G4 SCSI models only support U320 Universal Hot Plug drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 460W power supply (redundant power supply optional) | |
| Optical Drive | 24x IDE CD-ROM Drive (Low-profile) | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
|
DL360R04p X3.0-2MB/800, 1GB SCSI | Processor | (1) Intel Xeon Processor 3.0 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 1 GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Smart Array 6i Controller
(U320, embedded on system board) NOTE: The HP ProLiant DL360 G4p does not offer an external SCSI port. | |
| Hard Drives |
None ship standard; system supports up to two hot plug U320 drives NOTE: The HP ProLiant DL360 G4 SCSI models only support U320 Universal Hot Plug drives. | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 460W power supply (redundant power supply optional) | |
| Optical Drive | 24x IDE CD-ROM Drive (Low-profile) | |
| Diskette Drive | 1.44 MB Diskette Drive | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
| SATA Models | ||
|
DL360R04p X3.6-2MB/800, 1GB SATA |
Processor | (1) Intel Xeon Processor 3.6 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 1 GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Embedded SATA controller NOTE: The HP embedded 2 Port SATA controller does not support RAID, hot plug drive functionality or drive activity LEDs. NOTE: SATA RAID 0, 1 is available with the optional purchase of the HP 8-port SAS HBA (347786-B21) and HP SAS/SATA Cable Kit (398307-B21) - hot-plug drive functionality and drive activity LEDS not supported. |
|
| Hard Drives | None ship standard; system supports up to two Serial ATA drives | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 460W power supply (redundant power supply optional) | |
| Optical Drive | Optical Drives not supported on SATA Models | |
| Diskette Drive | Optional floppy on SATA Models | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
|
|
||
|
DL360R04p X3.4-2MB/800, 1GB SATA |
Processor | (1) Intel Xeon Processor 3.4 GHz/800MHz standard |
| Cache Memory | 2MB level 2 cache | |
| Memory | 1 GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Embedded SATA controller NOTE: The HP embedded 2 Port SATA controller does not support RAID, hot plug drive functionality or drive activity LEDs. NOTE: SATA RAID 0, 1 is available with the optional purchase of the HP 8-port SAS HBA (347786-B21) and HP SAS/SATA Cable Kit (398307-B21) - hot-plug drive functionality and drive activity LEDS not supported. |
|
| Hard Drives | None ship standard; system supports up to two Serial ATA drives | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 460W power supply (redundant power supply optional) | |
| Optical Drive | Optical Drives not supported on SATA Models | |
| Diskette Drive | Optional floppy on SATA Models | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133 MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
|
|
||
|
DL360R04p X3.2-2MB/800, 1GB SATA |
Processor | (1) Intel Xeon Processor 3.2 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 1 GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Embedded SATA controller NOTE: The HP embedded 2 Port SATA controller does not support RAID, hot plug drive functionality or drive activity LEDs. NOTE: SATA RAID 0, 1 is available with the optional purchase of the HP 8-port SAS HBA (347786-B21) and HP SAS/SATA Cable Kit (398307-B21) - hot-plug drive functionality and drive activity LEDS not supported. |
|
| Hard Drives | None ship standard; system supports up to two Serial ATA drives | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 460W power supply (redundant power supply optional) | |
| Optical Drive | Optical Drives not supported on SATA Models | |
| Diskette Drive | Optional floppy on SATA Models | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133 MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
|
|
||
|
DL360R04p X3.0-2MB/800, 1GB SATA |
Processor | (1) Intel Xeon Processor 3.0 GHz/800MHz standard (up to 2 supported) |
| Cache Memory | 2MB level 2 cache | |
| Memory | 1 GB (2 x 512 MB) Standard to 12 GB (Maximum) of PC2-3200 DDR2 400 SDRAM | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Embedded SATA controller NOTE: The HP embedded 2 Port SATA controller does not support RAID, hot plug drive functionality or drive activity LEDs. NOTE: SATA RAID 0, 1 is available with the optional purchase of the HP 8-port SAS HBA (347786-B21) and HP SAS/SATA Cable Kit (398307-B21) - hot-plug drive functionality and drive activity LEDS not supported. |
|
| Hard Drives | None ship standard; system supports up to two Serial ATA drives | |
| Remote Management | Integrated Lights-Out (iLO) Standard Management (embedded) | |
| Power Supply | One 460W power supply (redundant power supply optional) | |
| Optical Drive | Optical Drives not supported on SATA Models | |
| Diskette Drive | Optional floppy on SATA Models | |
| PCI-X Slots | 1 full length and 1 half length 64bit/133 MHz PCI-X slot | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
|
|
||
| Country Code Key | Rack Code Key | ||
| XX=00 | US | ||
| XX=20 | Brazil | ||
| XX=29 | Japan | ||
| XX=37 | APD | ||
| XX=42 | EURO | ||
| XX=AA | PRC | ||
|
|
Configuration Information - Factory Integrated Models (North America only)
|
NOTE: For Configure to Order requirements
within EMEA region, please consult local Sales Contact. | ||
| Step 1: Base Configuration (choose one of the following configurable models) | ||
| Models | HP ProLiant DL360G4p SATA Rack CTO Chassis (North America) | 382146-405 |
| Factory Integrated Model ships with: | ||
|
Embedded NC7782 PCI-X Gigabit Server Adapter | ||
| HP ProLiant DL360G4p SCSI Rack CTO Chassis (North America) |
382147-405 | |
|
Factory Integrated Model ships with: | ||
|
Embedded NC7782 PCI-X Gigabit Server Adapter | ||
| HP ProLiant DL360G4p SAS Rack CTO Chassis (North America) |
389831-405 | |
| Factory Integrated Model ships with: | ||
| Embedded NC7782
PCI-X Gigabit Server Adapter Integrated Lights-Out (iLO) embedded 1 full length and 1 half length 64-bit/133 MHz PCI-X slots 7 fans; N+1 fan redundancy Rack (1U), (1.75 in/4.45 cm) | ||
| | ||
| Step 1A: If SAS Model, Choose SAS Starter Kit or Controller (only one of the following) | ||
| SAS Controller | HP Smart Array
P600/256 BBWC Controller NOTE: This is a required selection if one of the two following SAS Starter Kits is not selected. If choosing this part number, 2.5" SAS hard drives must still be selected under Step 4. | 337972-B21 |
| SAS Starter Kit | NOTE: SAS Starter Kits are not compatible with the SCSI or SATA models. | |
| SAS
Starter Kit - 36GB NOTE: Includes Smart Array P600/256 BBWC Controller and (2) 36GB SFF SAS Universal Hard Drives. |
396221-B21 | |
| SAS Starter Kit
- 72GB NOTE: Includes Smart Array P600/256 BBWC Controller and (2) 72GB SFF SAS Universal Hard Drives. |
396220-B21 | |
| | ||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Intel X2.8GHz/800-2MB DL360G4 FIO processor | 399042-L21 |
| Intel X3.0GHz/800-2MB DL360G4 FIO processor | 380327-L21 | |
| Intel X3.0GHz/800-2M LV DL360G4 FIO processor | 394921-L21 | |
| Intel X3.2GHz/800-2MB DL360G4 FIO processor | 379817-L21 | |
| Intel X3.4GHz/800-2MB DL360G4 FIO processor |
376243-L21
|
|
| Intel X3.6GHz/800-2MB DL360G4 FIO processor |
376242-L21
|
|
| Intel X3.8GHz800-2M DL360G4 FIO processor |
376241-L21
|
|
| NOTE: Dual-core processor is supported on HP ProLiant DL360 G4p Serial Attached SCSI (SAS) model only. | ||
| Base Memory | 1 GB Advanced ECC PC2-3200 DDR2 SDRAM DIMM Memory Kit (2 x 512 MB) |
343055-B21
|
| 2 GB Advanced ECC PC2-3200 DDR2 SDRAM DIMM Memory Kit (2 x 1 GB) |
343056-B21
|
|
| 4 GB Advanced ECC PC2-3200 DDR2 SDRAM DIMM Memory Kit (2 x 2 GB) |
343057-B21
|
|
| Optical
Drive (may or may not be required. See notes) |
NOTE:
Optical Drives are OPTIONAL if choosing the (389831-405) SAS Rack CTO Chassis
Model or (382146-405) SATA Rack CTO Chassis Model in Step 1. NOTE: An Optical Drive is REQUIRED if choosing the 382147-405 SCSI Rack CTO Chassis Model in Step 1. |
|
| Slimline CD-RW/DVD-ROM
Combo Option Kit NOTE: This CD-RW/DVD-ROM Drive (PN 331903-B21) is for SAS and SCSI models. It is not supported in SATA models. |
331903-B21
|
|
| Slimline DVD-ROM
Drive (8X/24X) Option Kit NOTE: This DVD-ROM Drive (PN 264007-B21) is for SAS and SCSI models. It is not supported in SATA models. |
264007-B21
|
|
| Slimline CD-ROM
Drive 24X NOTE: This CD-ROM Drive (PN 356963-B21) is the only drive that will support SATA models. |
356963-B21
|
|
|
|
||
| Step 3: Choose Additional Factory Integratable Options | ||
| Diskette Drive | Slimline Ejectable
Floppy Drive NOTE: This Diskette Drive is for SAS (389831-405) models. |
390164-B21 |
| 1.44 MB Diskette
drive NOTE: This Diskette Drive is for SATA (382146-405) models |
354588-B21 | |
| Optical Drive | NOTE:
Optical Drives are OPTIONAL if choosing the (389831-405) SAS Rack CTO Chassis
Model or (382146-405) SATA Rack CTO Chassis Model in Step 1. NOTE: An Optical Drive is REQUIRED if choosing the 382147-405 SCSI Rack CTO Chassis Model in Step 1. |
|
| Slimline DVD-ROM
Drive (8X/24X) Option Kit NOTE: This DVD-ROM Drive (PN 264007-B21) is for SAS and SCSI models. It is not supported in SATA models. |
264007-B21
|
|
| Slimline CD-ROM
Drive 24X NOTE: This CD-ROM Drive (PN 356963-B21) is the only drive that will support SATA models. |
356963-B21
|
|
| Slimline CD-RW/DVD-ROM
Combo Option Kit NOTE: This CD-RW/DVD-ROM Drive (PN 331903-B21) is for SAS and SCSI models. It is not supported in SATA models. |
331903-B21
|
|
| Power Supply | 460W HP redundant
power supply with IEC cord only NOTE: For SCSI and SATA Models. |
354587-B21
|
| 535W HP redundant
power supply with IEC cord only NOTE: For SAS Models. |
389830-B21
|
|
| 535W HP redundant
power supply with NEMA or Japan cord only NOTE: for SAS Models. |
389830-001
|
|
|
|
||
| Step 4: Choose Additional Options for Factory Integration | ||
| NOTE: For additional options, please refer to the "Options" section below. |
|
|
Options
| NOTE: Some options may not be factory integratable. Please contact your local sales representative for additional information. | ||
| HP ProLiant DL360 G4p Unique Options | Intel Xeon Dual-core
2.8 GHz/800MHz-2x2MB 135W Processor Option Kit NOTE: This processor option kit (PN 408585-B21) supports the HP ProLiant DL360 G4p SAS only. |
408585-B21 |
| Intel Xeon 2.8G
Hz/800MHz-2MB 110W Processor Option Kit NOTE: This processor option kit (PN 399042-B21) supports the HP ProLiant DL360 G4p only. |
399042-B21 | |
| Intel Xeon 3.0
GHz/800MHz-2MB 110W Processor Option Kit NOTE: This processor option kit (PN 380327-B21) supports the HP ProLiant DL360 G4p only. |
380327-B21 | |
| Intel Xeon 3.0
GHz/800MHz-2MB 55W Low Voltage Processor Option Kit NOTE: This processor option kit (PN 394921-B21) supports the HP ProLiant DL360 G4p only. |
394921-B21 | |
| Intel Xeon 3.2
GHz/800MHz-2MB 110W Processor Option Kit NOTE: This processor option kit (PN 379817-B21) supports the HP ProLiant DL360 G4p only. |
379817-B21 | |
| Intel Xeon 3.4
GHz/800MHz-2MB 110W Processor Option Kit NOTE: This processor option kit (PN 376243-B21) supports the HP ProLiant DL360 G4p only. |
376243-B21 | |
| Intel Xeon 3.6
GHz/800MHz-2MB 110W Processor Option Kit NOTE: This processor option kit (PN 376242-B21) supports the HP ProLiant DL360 G4p only. |
376242-B21 | |
| Intel Xeon 3.8
GHz/800MHz-2MB 110W Processor Option Kit NOTE: This processor option kit (PN 376241-B21) supports the HP ProLiant DL360 G4p only. |
376241-B21
|
|
| PCI-e Riser option (to convert one or both PCI-X to PCI-e slots) |
354589-B21
|
|
| 460W HP redundant power supply with IEC cord only |
354587-B21
|
|
| 460W HP redundant
power supply with US or Japanese NEMA cord only NOTE: The HP ProLiant DL360 G4p ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). For stand-alone deployments or installation without a rack, country-specific power cord options are available. U.S., Japan, & APD models ship with two power cords: IEC-IEC and NEMA cords. |
354587-001
|
|
| 535W HP redundant power supply with IEC cord only |
389830-B21
|
|
| 535W HP redundant
power supply with US or Japanese NEMA cord only NOTE: The HP ProLiant DL360 G4p ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). For stand-alone deployments or installation without a rack, country-specific power cord options are available. U.S., Japan, & APD models ship with two power cords: IEC-IEC and NEMA cords. |
389830-001
|
|
|
|
||
| ProLiant
Essentials Value Pack Software |
ProLiant Essentials Intelligent Networking Pack | |
| ProLiant Essentials
Intelligent Networking Pack - Windows Edition, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
436225-B21 |
|
| NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_div/12062_div.html | ||
| ProLiant Essentials Intelligent Networking Pack - Linux Edition, Single Server License |
436229-B21
|
|
| NOTE:
For additional ProLiant Intelligent Networking Pack - Linux License Kits
please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_div/12327_div.html |
||
| ProLiant Essentials Performance Management Pack | ||
| ProLiant Essentials
Performance Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation. NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp. |
306696-B21 |
|
| NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.html | ||
| ProLiant Essentials Rapid Deployment Pack Windows Edition Release | ||
| Rapid Deployment
Pack, Single-Server License NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-B21 |
|
| Rapid Deployment
Pack, Single-Server License (Japan) NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-291 |
|
| NOTE:
For additional ProLiant Essentials Rapid Deployment Pack License Kits please
see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html |
||
| ProLiant Essentials Workload Management Pack | ||
| ProLiant Essentials Workload Management Pack, Single Server License |
303284-B21
|
|
| NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.html | ||
| ProLiant Essentials Virtualization Management Software | ||
| ProLiant Essentials
Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
435661-B21 |
|
| ProLiant
Essentials Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. |
435663-B21
|
|
| ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition, Single-Migration License |
412978-B21
|
|
| NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. | ||
| NOTE: For additional ProLiant Essentials Virtualization Management Software License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_div/12328_div.html | ||
| ProLiant Essentials Vulnerability and Patch Management Pack | ||
| ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
371645-B21
|
|
| NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.html | ||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
||
|
|
||
| Remote Management | Integrated Lights-Out Advanced Pack | |
| Integrated Lights-Out Advanced
Pack, 1 server Featuring: Sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites. |
263825-B21
|
|
| NOTE: For additional Integrated Light-Out Advanced Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11052_div/11052_div.html | ||
|
|
||
| ProLiant Software Maintenance Subscription | ProLiant Software Maintenance Subscription |
355060-B21
|
| ProLiant Software Maintenance Single Release |
356573-B21
|
|
| ProLiant Foundation Pack Single Release |
356604-B21
|
|
| NOTE: Please see
the SmartStart QuickSpecs for additional information regarding the subscription
purchase: http://h18000.www1.hp.com/products/quickspecs/division/11073.html (Worldwide) |
||
|
|
||
| Processor | Intel Xeon 2.8 GHz/800MHz-2MB
110W Processor Option Kit NOTE: This processor option kit (PN 399042-B21) supports the HP ProLiant DL360 G4p only. |
399042-B21
|
| Intel Xeon 3.0 GHz/800MHz-2MB
110W Processor Option Kit NOTE: This processor option kit (PN 380327-B21) supports the HP ProLiant DL360 G4p only. |
380327-B21
|
|
| Intel Xeon 3.0 GHz/800MHz-2MB
55W Processor Option Kit, Low Voltage NOTE: This processor option kit (PN 394921-B21) supports the HP ProLiant DL360 G4p only. |
394921-B21
|
|
| Intel Xeon 3.2 GHz/800MHz-2MB
110W Processor Option Kit NOTE: This processor option kit (PN 379817-B21) supports the HP ProLiant DL360 G4p only. |
379817-B21
|
|
| Intel Xeon 3.4 GHz/800MHz-2MB
110W Processor Option Kit NOTE: This processor option kit (PN 376243-B21) supports the HP ProLiant DL360 G4p only. |
376243-B21
|
|
| Intel Xeon 3.6 GHz/800MHz-2MB
110W Processor Option Kit NOTE: This processor option kit (PN 376242-B21) supports the HP ProLiant DL360 G4p only. |
376242-B21
|
|
| Intel Xeon 3.8 GHz/800MHz-2MB
110W Processor Option Kit NOTE: This processor option kit (PN 376241-B21) supports the HP ProLiant DL360 G4p only. |
376241-B21
|
|
|
|
||
|
Memory |
1 GB Advanced ECC PC2-3200 DDR2 SDRAM DIMM Memory Kit (2 x 512 MB) |
343055-B21
|
| 2 GB Advanced ECC PC2-3200 DDR2 SDRAM DIMM Memory Kit (2 x 1 GB) |
343056-B21
|
|
| 4 GB Advanced ECC PC2-3200 DDR2 SDRAM DIMM Single Rank Memory Kit (2 x 2 GB) |
343057-B21
|
|
| 4 GB Advanced ECC PC2-3200 DDR2 SDRAM DIMM Dual Rank Memory Kit (2 x 2 GB) |
375004-B21
|
|
|
|
||
| Optical Drives | Slimline CD-RW/DVD-ROM Combo Option
Kit NOTE: This CD-RW/DVD-ROM Drive (PN 331903-B21) is for SCSI and SAS models only. It is not supported in SATA models. |
331903-B21
|
| Slimline DVD-ROM Drive (8X/24X)
Option Kit (Servers) NOTE: This DVD-ROM Drive (PN 264007-B21) is supported on SCSI and SAS models. |
264007-B21
|
|
| Slimline CD-ROM Drive 24X NOTE: This CD-ROM Drive (PN 356963-B21) is the only drive that will support SATA models. |
356963-B21
|
|
| HP DVD+R/RW 8X Slim NOTE: This DVD+R/RW 8X Slim (PN 383975-B21) is supported on SCSI and SAS models. |
383975-B21
|
|
|
|
||
| Diskette Drive | Slimline Ejectable Floppy drive NOTE: This Diskette Drive is for SAS models only. |
390164-B21
|
| 1.44 MB Diskette Drive NOTE: This 1.44MB Diskette Drive (PN 354588-B21) is supported on SCSI and SATA models only. NOTE: Ships standard in SCSI models. |
354588-B21
|
|
|
|
||
| Hard Drives | Ultra320 – Hot Plug NOTE: The HP ProLiant DL360 G4p SCSI models support U320 Universal Hot Plug drives. |
|
| HP 300GB U320 10K Universal HDD |
350964-B22
|
|
| HP 146GB U320 10K Universal HDD |
286716-B22
|
|
| HP 72GB U320 10K Universal HDD |
286714-B22
|
|
| HP 300GB U320 15K Universal HDD |
411089-B22
|
|
| HP 146GB U320 15K Universal HDD |
347708-B22
|
|
| HP 72GB U320 15K Universal HDD |
286778-B22
|
|
| HP 36GB U320 15K Universal HDD |
286776-B22
|
|
| NOTE: Please see
the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature: http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.html (Worldwide) |
||
| Serial-ATA
(SATA) Hot Plug Hard Drive (For use with SATA Models) NOTE: The HP embedded 2 Port SATA controller does not support RAID, hot plug drive functionality or drive activity LEDs. |
||
| HP 750GB 1.5G SATA 7.2K 3.5"
HDD |
432341-B21
|
|
| HP 500GB 1.5G SATA 7.2K 3.5" HDD |
395473-B21
|
|
| HP 250GB 1.5G SATA 7.2K 3.5" HDD |
349239-B21
|
|
| HP 160GB 1.5G SATA 7.2K 3.5" HDD |
349238-B21
|
|
| HP 80GB 1.5G SATA 7.2K 3.5" HDD |
349237-B21
|
|
| SFF SATA Hot Plug |
||
| HP 60GB 1.5G SATA 5.4K SFF HDD |
379306-B21
|
|
|
NOTE: SATA drives have a 1-year warranty. Please see the SATA
Hard Drive QuickSpecs for Technical Specifications such as capacity, height,
width, interface, transfer rate, seek time, physical configuration, and
operating temperature: |
||
| Serial Attached SCSI (SAS) SFF Hot Plug (For use with SAS Models) | ||
| HP 146GB 3G SAS 10K SFF SP HDD |
431958-B21
|
|
| HP 72GB 3G SAS 10K SFF SP HDD
|
375861-B21
|
|
| HP 36GB 3G SAS 10K SFF SP HDD |
375859-B21
|
|
| NOTE: All SFF
SAS Universal Hard Drives are supported ONLY by HP ProLiant DL360 G4p SAS
models. NOTE: Please see the SAS Hard Drive QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/12224_div/12224_div.html (Worldwide) |
||
|
|
||
| Storage Controllers | SCSI Controllers | |
| 128MB Battery Backed Write Cache
Enabler Option Kit NOTE: Upgrade for Smart Array 6i Controller. |
346914-B21
|
|
|
Smart Array 6402/128 Controller |
273915-B21 |
|
|
Smart Array 6404/256 Controller |
273914-B21 |
|
|
Smart Array 642 Controller |
291967-B21 |
|
| 128MB Battery-Backed Cache Enabler NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller. |
351580-B21
|
|
| Ultra320 Expansion Module for
SA-6402 NOTE: For support of external drives only. |
273911-B21
|
|
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
|
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information:
http://h18000.www.1.hp.com/products/quickspecs/12030_div/12030_div.html (Smart Array 6i) http://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.html (Smart Array 6400 Series) http://h18000.www1.hp.com/products/quickspecs/11563_div/11563_div.html (Smart Array 642) http://h18000.www.1.hp.com/products/quickspecs/11943_div/11943_div.html (U320 SCSI G2 HBA) |
||
| SAS Controller | ||
| Smart Array P600 Controller | ||
| HP Smart Array P600/256 BBWC Controller |
337972-B21
|
|
| 512MB DDR BBWC Upgrade |
372538-B21
|
|
| NOTE: Ships standard
with SAS model. NOTE: Please see the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12247_div/12247_div.html (Smart P600 Controller) |
||
| SAS HBA | ||
| HP 8 Internal Port SAS HBA with
RAID NOTE: Supports SAS/SATA models. RAID 0,1 supported. |
347786-B21
|
|
| NOTE: Please see
the HBA QuickSpecs for additional information: http://h18004.www1.hp.com/products/quickspecs/12332_div/12332_div.html |
||
| HP
SATA/SAS 1U Cable Kit NOTE: Required for HP SAS/SATA HBA use with HP ProLiant DL360 G4p SATA models. |
398307-B21
|
|
|
|
||
| Communications | HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter |
367132-B21
|
| HP NC310F PCI-X 1000SX Gigabit Server Adapter |
368169-B21
|
|
| HP NC320T PCI Express 1000T Gigabit Server Adapter |
367047-B21
|
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC373F PCI Express Multifunction
Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter |
394795-B21
|
|
| HP NC510F PCIe 10 Gigabit Server
Adapter NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510F adapter. |
414126-B21
|
|
| HP NC510C PCIe 10 Gigabit Server
Adapter NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510C adapter. |
414129-B21
|
|
| HP NC1020 PCI 1000T Gigabit Server Adapter |
353377-B21
|
|
| HP NC7771 PCI-X 1000T Gigabit Server Adapter |
290563-B21
|
|
| NOTE: Any NIC (except the NC1020) on the option list can be used for redundancy with the embedded NC7782 Dual Port Network Controller. When teaming with other NICs or with the embedded NIC, the lack of Jumbo Frames and LSO features on the NC1020 will cause high end NICs to have those features disabled. (e.g. incompatibility issues with the other option NICs for that platform). | ||
| HP IB 4X SDR PCI-e single PORT
HCA |
431038-B21
|
|
| HP IB 4X DDR PCI-e Single PORT HCA |
431039-B21
|
|
|
|
||
| Management Options | Remote Insight Lights-Out Edition II (NA, LA) |
227251-001 |
| Remote Insight Lights-Out Edition II (EMEA) |
227251-021 |
|
| Remote Insight Lights-Out Edition II (ROW) |
227251-371 |
|
|
|
||
|
Tape Drives |
| ||||||||||||||||||||||||||||||||
| | |||||||||||||||||||||||||||||||||
| Tape Autoloaders |
HP StorageWorks DAT Autoloader | |
| HP StorageWorks DAT 72x10 tape autoloader | AE313A | |
| HP StorageWorks 1/8 Tape Autoloader | ||
| HP StorageWorks 1/8 Ultrium 920 G2 Tape Autoloader | AH165A | |
| HP StorageWorks 1/8 Ultrium 448 G2 Tape Autoloader | AH164A | |
| HP StorageWorks 1/8 Ultrium 232 G2 Tape Autoloader | AH163A | |
| HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions |
AH166A | |
| NOTE: Please reference the Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
|
|
||
| Tape Libraries | HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 Ultrium
960 Drive Library |
AG115A | |
| HP StorageWorks MSL2024 1 Ultrium
960 4GB FC Drive Library |
AG326B | |
| HP StorageWorks MSL2024 1 Ultrium
920 Drive Library |
AH169A | |
| HP StorageWorks MSL2024 2 Ultrium 920 Drive Library | AH170A | |
| HP StorageWorks MSL2024 1 Ultrium 448 Drive Library | AG116A | |
| HP StorageWorks MSL2024 2 Ultrium 448 Drive Library | AG117A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 1 Ultrium
448 Drive Library |
AG320A | |
| HP StorageWorks MSL4048 2 Ultrium
448 Drive Library |
AG321A | |
| HP StorageWorks MSL4048 1 Ultrium
920 Drive Library |
AH171A | |
| HP StorageWorks MSL4048 2 Ultrium
920 Drive Library |
AH172A | |
| HP StorageWorks MSL4048 1 Ultrium
960 Drive Library |
AG322A | |
| HP StorageWorks MSL4048 1 Ultrium
960 4GB FC Drive Library |
AG324B | |
| HP StorageWorks MSL4048 2 Ultrium
960 Drive Library |
AG323A | |
| HP StorageWorks MSL4048 2 Ultrium 960 4GB FC Drive Library | AG325B | |
| HP StorageWorks MSL6000 Tape Library | ||
| Ultrium 960 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library | AD606B | |
| HP StorageWorks MSL6030 1 Ultrium 960 Dr FC Library | AD608B | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library | AD607B | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library | AD609B | |
| Ultrium 460 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 460 Dr LVDS Library | AD598B | |
| HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library | AD600B | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library | AD599B | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library | AD601B | |
| NOTE: Please reference the MSL2024, MSL4048, and MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
|
|
||
| Power Cords | NOTE: The HP ProLiant DL360 G4p ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). For stand-alone deployments or installation without a rack, country-specific power cord options are available. U.S. & Japan models will ship with two power cords: IEC-IEC (142257-002) and North American C13-Nema 5-15P (103541-001) cords. | |
| Power Cord, Euro, 10A 250 V Straight (12 ft/3.7 m) |
157215-021
|
|
| Power Cord, UK, 10A 250 V Straight (12 ft/3.7 m) |
157216-031
|
|
| Power Cord, Danish, 10A 250 V Straight (12 ft/3.7 m) |
157218-081
|
|
| Power Cord, Swiss, 10A 250 V Straight (12 ft/3.7 m) |
157219-111
|
|
| Power Cord, Italian, 10A 250 V Straight (12 ft/3.7 m) |
157217-061
|
|
| Power Cord, South Africa, 10A 250 V Straight (12 ft/3.7 m) |
157220-AR1
|
|
|
|
||
| HP StorageWorks Modular Smart Array 20 | HP StorageWorks Modular Smart
Array 20 NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. |
335921-B21 |
| HP StorageWorks Modular Smart
Array 20 Starter Kit NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller. |
366172-B21 | |
| NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 3.5” Hot Plug Hard Drives. | ||
|
|
||
| HP StorageWorks Modular Smart Array 30 | HP StorageWorks Modular Smart
Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies |
302969-B21 |
| HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies |
302970-B21 | |
| NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 Hot Plug Hard Drives. | ||
|
|
||
|
HP StorageWorks Modular Smart Array 50 |
HP StorageWorks Modular Smart Array 50 Enclosure |
364430-B21 |
| NOTE:
Please see the Modular Smart Array 50 QuickSpecs for additional information including
configuration steps and additional options needed for a complete solution at:
http://h18000.www1.hp.com/products/quickspecs/12245_div/12245_div.html (Worldwide) | ||
| | ||
|
HP StorageWorks Modular Smart Array 500 |
HP StorageWorks Modular Smart Array 500 Generation 2 |
335880-B21 |
| NOTE:
Please see the Modular Smart Array 500 Generation 2 QuickSpecs for additional
information including configuration steps and additional options needed for a
complete solution at: http://h18000.www1.hp.com/products/quickspecs/11956_div/11956_div.html (Worldwide) | ||
| | ||
|
HP StorageWorks Modular Smart Array 1000 |
HP StorageWorks Modular Smart Array 1000 |
201723-B22 |
| NOTE:
Please see the Modular Smart Array 1000 QuickSpecs for additional options
and configuration information at http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.html (Worldwide) | ||
| | ||
| HP StorageWorks Modular Smart Array 1500 cs | Modular Smart Array 1500 Controller Shelf |
AA986A
|
| NOTE: Please see
the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options
and configuration information at: http://www.hp.com/go/MSA1500cs |
|
|
|
|
||
| StorageWorks Options | NOTE: The following
is a list of all Fibre Channel Host Bus Adapters for Windows, Linux and
Netware. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html |
|
| HP StorageWorks FC2142SR 4Gb PCI-e
HBA |
A8002A
|
|
| HP StorageWorks FC2242SR Dual
Channel 4 Gb PCI-e HBA |
A8003A
|
|
| HP StorageWorks FC1142SR 4Gb PCI-e
HBA |
AE311A
|
|
| HP StorageWorks FC1242SR Dual
Channel 4 Gb PCI-e HBA |
AE312A
|
|
| HP StorageWorks FC2143 4Gb PCI-X
2.0 -to-Fibre Channel HBA |
AD167A
|
|
| HP StorageWorks FC2243 Dual Channel
4Gb PCI-X 2.0 HBA |
AD168A
|
|
| HP StorageWorks FC1143 4Gb PCI-X
2.0 HBA |
AB429A
|
|
| HP StorageWorks FC1243 Dual Channel
4Gb PCI-X 2.0 HBA |
AE369A
|
|
|
|
||
| Cluster Options | ProLiant Cluster Starter Kit |
364023-B22
|
| NOTE: For additional
information regarding the ProLiant Cluster Starter Kit please see the following
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_div/11935_div.html (Worldwide) |
||
| HP HA/F200 for Entry SAN Cluster |
364026-B22
|
|
| NOTE: For additional
information regarding the ProLiant Cluster for Entry Level SAN please see
the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11932_div/11932_div.html (Worldwide) |
||
| ProLiant Cluster HA/F500 for the Enterprise SAN |
364024-B21
|
|
| NOTE: For additional
information regarding the ProLiant Cluster HA/F500 for Enterprise SAN please
see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11933_div/11933_div.html (Worldwide) |
||
| HP Serviceguard for Linux ProLiant
Cluster A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 (2 node
license cluster kit) |
305199-B26
|
|
| HP Serviceguard for Linux A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 (single license version) |
307754-B26
|
|
| HP Serviceguard for Linux and Red Hat Global File System - 1 year subscription |
T2798AA#001
|
|
| HP Serviceguard for Linux and Red Hat Global File System - 3 years subscription |
T2798AA#003
|
|
| NOTE: For additional
information regarding HP Serviceguard for Linux, please see the following
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html (Worldwide) |
||
|
|
||
| Uninterruptible Power Systems – Rack Mountable | HP, R1.5kVA UPS, 1U, NA |
AF419A
|
| HP, R1.5kVA UPS, 1U, INTL |
AF418A
|
|
| HP, R1.5kVA UPS, 1U, JPN/TW |
AF421A
|
|
| HP R3000 VA UPS, 2U, DTC, INTL NOTE: Replaces non-RoHs compliant part numbers 192186-B31, 192186-B32, 192186-B33, 192186-AR1. |
AF414A
|
|
| HP R3000 VA UPS, 2U, L5-30, NA NOTE: Replaces non-RoHs compliant part number 192186-001. |
AF422A
|
|
| HP R3000 VA UPS, 2U, L6-20, NA NOTE: Replaces non-RoHs compliant part number 192186-002. |
AF423A
|
|
| HP R3000 VA UPS, 2U, L6-20, JPN NOTE: Replaces non-RoHs compliant part number 192186-292. |
AF424A
|
|
| HP R3000 VA UPS, 2U, L5-30, JPN NOTE: Replaces non-RoHs compliant part number 192186-291. |
AF425A
|
|
| HP R5500 VA UPS, INTL NOTE: Replaces non-RoHs compliant part number 326529-B31. |
AF416A
|
|
| HP R5500 VA UPS, NA/JPN NOTE: Replaces non-RoHs compliant part number 326529-D71. |
AF426A
|
|
|
|
||
| HP Monitored Power Distribution Unit (PDU) | HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 17.3 kVA S2324 Monitored PDU-
dual input, 3U, 24A (NA/JPN) NOTE: Replaces non-RoHs compliant part number 370959-D71. |
AF503A
|
|
| HP 8.3 kVA S1324 Monitored PDU-
single input, 3U, 24A (NA/JPN) NOTE: Replaces non-RoHs compliant part number 370960-D71. |
AF504A
|
|
| HP 16.6 kVA S2140 Monitored PDU-
dual input, 1U, 40A (NA/JPN) NOTE: Replaces non-RoHs compliant part number 37061-D71. |
AF505A
|
|
| HP 8.6 S1140 Monitored PDU- single
input, 1U, 40A (NA/JPN) NOTE: Replaces non-RoHs compliant part number 370962-D71. |
AF506A
|
|
| HP 22.1 kVA S2316 Monitored PDU-
dual input, 3U, 16A (INTL) NOTE: Replaces non-RoHs compliant part number 370963-B31. |
AF507A
|
|
| HP 11 kVA S1316 Monitored PDU-
single input, 3U, 16A (INTL) NOTE: Replaces non-RoHs compliant part number 370964-B31. |
AF508A
|
|
| HP 14.7 kVA S2132 Monitored PDU-
dual input, 1U, 32A (INTL) NOTE: Replaces non-RoHs compliant part number 370965-B31. |
AF509A
|
|
| HP 7.3kVA S1132 Monitored PDU-
single input, 1U, 32A (INTL) NOTE: Replaces non-RoHs compliant part number 370966-B31. |
AF510A
|
|
|
|
||
|
Modular PDUs 1U/0U | Fixed Cord
Extension Bars NOTE: Two extension bar sticks; each with (7) C13 plugs. |
351655-B21 |
| Fixed
Cord PDU (NA/JPN) NOTE: Four Fixed Cord Extension Bars, and one 24A, HV mPDU L6-30P core. |
351655-D72 | |
| Fixed
Cord PDU (INTL) NOTE: Four Fixed Cord Extension Bars, and one 32A, HV mPDU IEC-309 core. |
351655-B31 | |
| HP
Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC) (NA,
Japan) NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR. |
252663-D71 | |
|
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC) (NA, Japan) | 252663-D72 | |
| HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC) (Int’l) |
252663-B31 | |
|
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)
(WW) |
252663-B21 | |
|
HP Modular Power Distribution Unit(mPDU), High Volt Model, 16A (200-240 VAC) (WW) | 252663-B24 | |
| HP Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached Cord, (NA/JPN) |
252663-D73 | |
| HP Modular Power Distribution Unit (mPDU), High Volt Model, 40A, Attached Cord, (Int'l) | 252663-B32 | |
| NOTE: This PDU has a detachable input power cord and allows for adaptability to country specific power requirements. This model may also be used with the high volt UPSs R3000 XR and R6000 For North America, need to order cable PN 340653-001. | ||
| NOTE:
Please see the following Modular Power Distribution Unit (Zero-U/1U Modular
PDUs) QuickSpecs for additional options including shorter jumper cables and country
specific power cords: http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.html (Worldwide) | ||
| | ||
| USB Options | HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) |
DC172B
|
| HP USB 04 Standard Keyboard |
DT528A#xxx
|
|
| USB 2.0 4-port HUB |
DG954A
|
|
| HP 1GB Drive Key II- USB 2.0 Flash
Drive |
AG382AA
|
|
| HP 512MB DriveKey II- USB Flash Drive |
ED516AA
|
|
|
|
||
| HP ProLiant DL360 G4p Deployment Options | 460W HP redundant power supply with IEC cord only |
354587-B21
|
| 460W HP redundant power supply
with US or Japanese NEMA cord only NOTE: The HP ProLiant DL360 G4p ships with a single IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). For stand-alone deployments or installation without a rack, country-specific power cord options are available. U.S., Japan, & APD models ship with two power cords: IEC-IEC and NEMA cords. |
354587-001
|
|
| 535W HP redundant power supply with IEC cord only |
389830-B21
|
|
| 535W HP redundant power supply
with US or Japanese NEMA cord only NOTE: The HP ProLiant DL360 G4p ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). For stand-alone deployments or installation without a rack, country-specific power cord options are available. U.S., Japan, & APD models ship with two power cords: IEC-IEC and NEMA cords. |
389830-001
|
|
|
|
||
| Rack Kits | 1U Cable Management Arm NOTE: Package contains two cable management arms. |
365403-B21
|
|
|
||
|
HP Rack 5000 Series | HP 5642 Rack Unassembled | 358254-B21 |
| NOTE:
Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical
Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.html (Worldwide) NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
|
HP Rack 10000 G2 Series |
10642 G2 (42U) Rack Cabinet - Pallet |
AF001A
|
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A
|
|
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A
|
|
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet |
AF004A
|
|
| 10636 G2 (36U) Rack Cabinet - Pallet |
AF011A
|
|
| 10636 G2 (36U) Rack Cabinet - Shock Pallet |
AF012A
|
|
| 10636 G2 (36U) Rack Cabinet - Crated |
AF013A
|
|
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet |
AF014A
|
|
| NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. | ||
| NOTE: Please see
the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html (Worldwide) |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
|
HP Rack 10000 Series |
10642 (42U) Infrastructure Rack (Low Voltage) |
379006-001
|
| 10642 (42U) Infrastructure Rack (High Voltage) |
379005-001
|
|
| HP Rack S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22
|
|
| HP Rack 10842 (42U, 800mm wide) – Pallet |
257415-B21 |
|
| HP Rack 10842 (42U, 800mm wide) – Shock Pallet |
257415-B22 |
|
| HP Rack 10647 (47U) – Pallet |
245160-B21 |
|
| HP Rack 10647 (47U) – Crated |
245160-B23 |
|
| HP Rack 10622 (22U) – Pallet |
245163-B21 |
|
| HP Rack 10622 (22U) – Shock Pallet |
245163-B22 |
|
| HP Rack 10622 (22U) – Crated |
245163-B23 |
|
|
NOTE: xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). xxxxxx-B23 (crated) used for air shipments of empty racks. |
|
|
|
NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. Not all HP equipment is qualified to be shipped in the Rack 10000 series |
|
|
|
NOTE: Please see the Rack 10000
QuickSpecs for Technical Specifications such as height, width, depth,
weight, and color: |
|
|
|
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower |
|
|
|
|
||
|
Keyboards and Monitors | TFT7210R
Rack Mounted 17" Monitor NOTE: For a complete list of Monitors please view the following URL: http://www.hp.com/go/kvm | 348373-B21 |
| TFT7600 Rackmount Keyboard Monitor US | AG052A | |
| TFT7600 Rackmount Keyboard Monitor UK | AG053A | |
| TFT7600 Rackmount Keyboard Monitor GR | AG054A | |
| TFT7600 Rackmount Keyboard Monitor FR | AG055A | |
| TFT7600 Rackmount Keyboard Monitor IT | AG056A | |
| TFT7600 Rackmount Keyboard Monitor SP | AG057A | |
| TFT7600 Rackmount Keyboard Monitor DEN | AG058A | |
| TFT7600 Rackmount Keyboard Monitor NOR | AG059A | |
| TFT7600 Rackmount Keyboard Monitor SE/FI | AG060A | |
| TFT7600 Rackmount Keyboard Monitor SWI | AG061A | |
| TFT7600 Rackmount Keyboard Monitor PORT | AG062A | |
| TFT7600 Rackmount Keyboard Monitor BEL | AG063A | |
| TFT7600 Rackmount Keyboard Monitor JPN2 | AG064A | |
| TFT7600 Rackmount Keyboard Monitor RUS | AG065A | |
| TFT7600 Rackmount Keyboard Monitor INTL | AG066A | |
| 1U Rackmount Keyboard with USB, US | AG072A | |
| 1U Rackmount Keyboard with USB, UK | AG073A | |
| 1U Rackmount Keyboard with USB, GR | AG074A | |
| 1U Rackmount Keyboard with USB, FR | AG075A | |
| 1U Rackmount Keyboard with USB, ITL | AG076A | |
| 1U Rackmount Keyboard with USB, SP | AG077A | |
| 1U Rackmount Keyboard with USB, DEN | AG078A | |
| 1U Rackmount Keyboard with USB, NOR | AG079A | |
| 1U Rackmount Keyboard with USB, SE/FI | AG080A | |
| 1U Rackmount Keyboard with USB, SWI | AG081A | |
| 1U Rackmount Keyboard with USB, PORT | AG082A | |
| 1U Rackmount Keyboard with USB, BEL | AG083A | |
| 1U Rackmount Keyboard with USB, JPN2 | AG084A | |
| 1U Rackmount Keyboard with USB, RUS | AG085A | |
| 1U Rackmount Keyboard with USB, INTL | AG086A | |
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower | ||
| | ||
|
HP KVM Switch Options |
2x1x16 IP Console Switch with Virtual Media |
AF601A
|
| 4x1x16 IP Console Switch with Virtual Media |
AF602A
|
|
| 2x16 Server Console Switch with Virtual Media |
AF600A
|
|
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A
|
|
| Server Console Switch (KVM), 0 x 1 x 8 port |
336044-B21
|
|
| Server Console Switch (KVM), 0 x 2 x 16 port |
336045-B21
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| USB Interface Adapter, 1 pack |
336047-B21
|
|
| Serial Interface adapter - 1 Pack with power supply |
373035-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x 4 USB/PS2 KVM Switch, TT (NA/JPN) |
371301-D71
|
|
| HP 1x 4 USB/PS2 KVM Switch, TT (AU/NZ) |
371301-011
|
|
| HP 1x 4 USB/PS2 KVM Switch, TT (UK) |
371301-031
|
|
| HP 1x 4 USB/PS2 KVM Switch, TT (EU) |
371301-A21
|
|
| HP 1x 4 USB/PS2 KVM Switch, RM (ALL) |
371302-B21
|
|
| HP PS2 KVM Cable with audio, 6', 2-pack |
371730-B21
|
|
| HP USB KVM Cable with audio, 6', 2-pack |
371729-B21
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
|
HP Serial Console Server Options |
HP 16 Port Serial Console Server (worldwide) |
AF101A
|
| HP 48 Port Serial Console Server (worldwide) |
AF102A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A
|
|
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| Service and Support Offerings (HP Care Pack Services) |
|
|
|
Memory
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
|
HP ProLiant DL360 G4p Standard Models |
|
Standard Memory Upgrading Memory
and Memory Interleaving Standard Memory Plus
Optional Memory Standard Memory Replaced with Optional Memory NOTE: Chart does not represent all possible configurations. |
|
Memory
|
Slot | ||||||
| 1 | 2 | 3 | 4 | 5 | 6 | ||
| Standard | 1 GB |
512 MB
|
512 MB
|
Empty
|
Empty
|
Empty
|
Empty
|
| Optional | 9 GB |
512 MB
|
512 MB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
| Maximum | 12 GB |
2 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
| NOTE: In the online spare configuration, the ROM automatically configures the last populated bank as the spare memory. If only banks A and B are populated, bank B is the spare bank. If banks A, B, and C are populated, bank C is the spare bank, Online spare memory is configured through RBSU. |
|
Following are memory options available from HP: |
|
|
343055-B21 |
|
343056-B21 |
|
343057-B21 |
|
375004-B21 |
|
|
|
|
HP ProLiant DL360 G4p RPS Models |
|
Standard Memory Upgrading Memory and Memory Interleaving Standard Memory Plus Optional Memory Standard Memory Replaced with Optional Memory NOTE: Chart does not represent all possible configurations. |
|
Memory |
Slot |
||||||
|
1 |
2 |
3 |
4 | 5 |
6 |
||
|
Standard |
2 GB |
1 GB
|
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
|
Optional |
10 GB |
1 GB
|
1 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
|
Maximum
|
12 GB |
2 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
2 GB
|
| NOTE: In the online spare configuration, the ROM automatically configures the last populated bank as the spare memory. If only banks A and B are populated, bank B is the spare bank. If banks A, B, and C are populated, bank C is the spare bank, Online spare memory is configured through RBSU. |
| Following are memory options available from HP: | |
| 343055-B21 |
| 343056-B21 |
| 343057-B21 |
| 375004-B21 |
| | |
| NOTE:
Online Spare Memory is not supported when using 2-rank DIMMs. A total of 8 ranks
are supported on the HP ProLiant DL360 G4p, A maximum of 4, 2-rank DIMMs can be
populated. If you plan to mix DIMM types, 2-rank DIMMs must be installed in the
first bank, 1 rank DIMMs can then be installed in subsequent banks. Key: S denotes single rank kit, D denotes Dual rank kit, and X denotes no install. | |
|
Bank A |
Bank B |
Bank C |
NOTES: |
|
S | X |
X | |
| S |
S | X |
|
|
S | S |
S | |
| D |
X | X |
Online spare not supported |
|
D | S |
X | Online
spare not supported |
|
D | S |
S | Online
spare not supported |
|
D | D |
X | Online
spare not supported |
|
|
Storage
![]() | 1,0 | Two Ultra320 Hot Pluggable Hard Drive Bays; SATA model also available |
| A | 1.44-MB Diskette Drive (removeable) | |
| B | Low-Profile 24x IDE CD-ROM (ejectable) | |
![]() |
1,2,3,4 |
Four SFF Serial Attached SCSI Hot Pluggable Hard Drive Bays |
| A | Multibay: Slimline 24x CD-ROM (ejectable) | |
| Drive Support - SAS Models | |||
|
|
|||
|
Quantity |
Position |
|
|
|
Removable Media |
|||
|
Slimline 1.44-MB Diskette Drive |
Up to 1 |
A
|
Integrated |
|
Slimline 24x IDE CD-ROM Drive |
Up to 1
|
A
|
Integrated IDE |
| Slimline DVD-Rom Drive (8x/24x) Option Kit (Servers) |
Up to 1
|
A
|
Integrated IDE |
|
|
|||
| Drive Support - SCSI Models | |||
|
|
|||
|
Quantity |
Position |
|
|
|
Removable Media |
|||
|
1.44-MB Diskette Drive |
Up to 1 |
A
|
Integrated |
|
Slimline 24x IDE CD-ROM Drive |
Up to 1
|
B
|
Integrated IDE |
| Slimline DVD-Rom Drive (8x/24x) Option Kit (Servers) |
Up to 1
|
B
|
Integrated IDE |
|
|
|||
| Hard Drives | |||
| Ultra320 Hot Pluggable Drives NOTE: The HP ProLiant DL360 G4p only supports U320 Universal drives. |
|||
|
Quantity
Supported |
Position
Supported |
Controller |
|
| 300GB U320 10K 146GB U320 10K 72GB U320 10K 300GB U320 15K 146GB U320 15K 72GB U320 15K 36GB U320 15K |
Up to 2
|
0-1
|
Smart Array 6i Controller (integrated
on system board) NOTE: The HP ProLiant DL360 G4p does not offer an external SCSI port. Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
|
|
|||
| SFF SAS Hard Drive | |||
|
Quantity
Supported |
Position
Supported |
Controller |
|
| 146GB 3G SAS 10K SP 72GB 3G SAS 10K SP 36GB 3G SAS 10K SP |
4
|
1-4
|
HP Smart Array P600/256 BBWC Controller |
|
|
|||
| Serial-ATA (SATA) Hard Drive NOTE: The HP embedded 2 Port SATA controller does not support RAID, hot plug drive functionality or drive activity LEDs. |
|||
|
Quantity |
Position |
|
|
| 700GB 1.5G SATA 7.2K 500GB 1.5G
SATA 7.2K 250GB 1.5G SATA 7.2K 160GB 1.5G SATA 7.2K 80GB 1.5G SATA 7.2K |
Up to 2 |
0-1 |
HP embedded 2 Port SATA Controller with RAID 0/1 support |
| Serial-ATA (SATA) SFF Hard
Drive NOTE: The HP embedded 2 Port SATA controller does not support RAID, hot plug drive functionality or drive activity LEDs. |
|||
| 60GB 1.5G SATA 5.4K |
Up to 2
|
0-1
|
HP embedded 2 Port SATA Controller with RAID 0/1 support |
|
|
|||
|
External Storage | ||||
| Quantity | Position
|
| ||
| Modular Smart Array 20 Family |
Please see the Modular Smart Array 20 QuickSpecs to determine configuration requirements |
External |
Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 | |
| Modular Smart Array 30 Family |
Please see the Modular Smart Array 30 QuickSpecs to determine
configuration requirements. |
External | Smart
Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
|
| Modular Smart Array 50 Enclosure |
2 |
External |
HP Smart Array P600/256 BBWC Controller | |
| Modular Smart Array 500 G2 System |
1 |
External | Smart
Array 642 Controller (used as Host Bus Adapter) Please see the Modular Smart Array 500 G2 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/msa500 | |
| Modular Smart Array 1500 cs |
Please see the Modular Smart Array 1500 cs QuickSpecs below
to determine configuration requirements |
External | Please see the Modular Smart Array 1500 cs QuickSpecs (URL below) for the latest list of supported HBAs | |
| Modular Smart Array 1000 |
Please see the Modular Smart Array 1000 QuickSpecs below to
determine configuration requirements |
External | Please see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of supported HBAs | |
| Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.html
(Worldwide) Modular Smart Array 1500 cs: http://www.hp.com/go/MSA1500cs | ||||
| | ||||
| Tape Drives, Tape Autoloaders, & Tape Libraries | ||||
|
NOTE: For an up-to-date listing of the
latest O/S Support details for each of the Tape Drives listed below, please
see the following: For recommended tape drive offerings for this ProLiant server see the following: |
||||
|
Position
Supported |
Controller
|
Controller Part Numbers
|
||
| HP StorageWorks Tape Drives,
External DAT 24 USB DAT 40 USB DAT 72 USB |
External
|
USB 2.0 Port
|
N/A
|
|
| HP StorageWorks Tape Drives,
External Ultrium 232 Ultrium 448 Ultrium 460 Ultrium 920 Ultrium 960 DAT 40 DAT 72 DLT VS160 SDLT 600 |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
|
374654-B21 |
|
| HP StorageWorks Autoloaders,
External DAT 72x10 Autoloader 1/8 G2 Tape Autoloader |
External |
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
|
374654-B21 |
|
| HP StorageWorks SCSI Rack-Mount
Tape Drive Enclosures 1U Rack-Mount Kit 3U Rack-Mount Kit |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
|
374654-B21 |
|
| HP StorageWorks USB Rack-Mount
Tape Drive Enclosures 1U Rack-Mount Kit |
External
|
USB 2.0 Port
|
N/A |
|
| HP StorageWorks Tape Libraries,
External MSL2024 (Ultrium 448, Ultrium 920 and 960-based) MSL4048 (Ultrium 448, Ultrium 920 and 960-based) MSL6000 (Ultrium 960 and 460-based) MSL6000 (SDLT 600-based) |
External
|
Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs
for detailed connectivity information.
|
N/A
|
|
|
|
Power Specifications
| To review typical system
power ratings use the Active Answers Power Calculator which is available
via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
To drill down to calculators: |
|
|
Technical Specifications
| System Unit | Dimensions (H x W x D) | 1.70 x 16.78 x 27.75 in (4.32 x 42.62 x 70.49 cm) | |
| Weight | Maximum (two hard drives installed, two power supply, two processor) | 37 lb (16.78 kg) | |
| No hard drives installed, one power supply, one processor | 27.5 lb (12.47 kg) | ||
| Input Requirements | Rated Input Voltage | 100 to 240 VAC | |
| Rated Input Current | 5.85 Amps (100 V) to 2.85 Amps (200 V) | ||
| Rated Input Frequency | 50 to 60 Hz | ||
| Rated Input Power | 585 W (100VAC) to 565 W (200VAC)
NOTE: 585 W of Rated Input Power is for the Maximum Peak Output Power of 535 W. |
||
| BTU Rating |
2000 BTU/HR NOTE: The BTU rating listed is for the Rated Input Power of 585 W. |
||
| Power Specifications | To review typical system power
ratings use the Power Calculator which is available via the online tool
located at URL: http://h30099.www3.hp.com/configurator/calc /Power%20Calculator%20Catalog.xls To drill down to calculators: |
||
| Power Supply Output Power
(per power supply) |
Rated Steady-State Power | 535 W | |
| Temperature Range | Operating | 10° to 35°C at sea level with an altitude derating of 1.0°C per every 300m (1000ft) above sea level to a maximum of 3000m (10,000ft), no direct sustained sunlight. Maximum rate of change is 10°C/Hr. | |
| Storage | -30° to 60°C - Maximum rate of change is 20°C/Hr. | ||
| Relative Humidity
(non-condensing) |
Operating | 10 to 90% relative humidity (Rh), 28°C maximum wet bulb temperature | |
| Storage | 5 to 95% relative humidity (Rh), 38.7°C maximum wet bulb temperature | ||
| Maximum Wet Bulb Temperature | 38.7° C | ||
| SCSI Connectors | No external VHDCI connector | ||
| Acoustic Noise | Idle (Fixed Disk Drives Spinning) |
||
L WAd (BELS) |
6.6 | ||
L pAm (dBA) |
50 | ||
| Operating (Random Seeks to Fixed Disks) |
|||
L WAd (BELS) |
6.9 BELS | ||
L pAm (dBA) |
53 dBA | ||
|
|
|||
| Smart Array 6i Controller
(integrated on system board) (SCSI models) |
Data Compatible with all Smart Array Controllers | Yes |
| Instant Upgrades to other Smart Array Controllers | Yes | |
| Consistent Software Manageability Tools | Yes | |
| PCI-X Bus | 64-bit up to 133 (integrated on system board) | |
| PCI-X Peak Data Transfer Rate | 1066 MB/s | |
| SCSI Protocols Supported | Ultra320, Ultra3, Ultra2 | |
| SCSI Peak Data Transfer Rate | 320 MB/s | |
| Channels | 1 | |
| SCSI Ports (external/internal) |
0/1 |
|
| Drives Supported (maximum) |
2 drives |
|
| Cache | 64 MB Read Cache | |
| Battery-Backed Write Cache | Yes, with installation of Battery-Backed Write Cache Enabler, up to 128MB | |
| RAID Support | 0, 1, 1+0, 5 | |
| Logical Drives (maximum) |
32 logical drives | |
| Online Configuration | Yes | |
| Online Capacity Expansion | Yes | |
| Logical Drive Capacity Extension | Yes | |
| Online Stripe Size Migration | Yes | |
| Online RAID Level Migration | Yes | |
| Online Spare Support | Yes | |
| Automatic Data Recovery | Yes | |
| Drive Roaming | Yes | |
|
|
||
| Integrated Serial
ATA Controller (SATA models) |
Simultaneous drive transfer channels | Support for up to 2 hard drives |
| Transfer rate synchronous (maximum theoretical) | 150 MB/s per channel; 300MB/s in RAID 0 pair | |
| Protocol | Serial ATA | |
| Drive support | HP Universal Serial ATA | |
| Data transfer modes | ATA data-transfer modes supported SATA 1.0, SATA II PIO modes 0-4 Multiword DMA modes 0-2 Ultra DMA modes 0-6 |
|
| Feature | Supports Pre-Failure Warranty of
SATA Hard Drives Support for Systems Insight Manager Supports multiple logical volumes Setup through ROM based Array Configuration Utility Installation scripting support |
|
| OS Support | Microsoft Windows 2000 Server Microsoft Windows Server 2003 Novell NetWare Linux (Red Hat, SuSE, UnitedLinux) |
|
| NOTE: This controller does not support LED functions. This controller does not support Hot Plug functions. | ||
|
|
||
| Smart Array P600
Controller (SAS models only) |
Disk Drive and Enclosure Protocol Support | 3 Gbps SAS (Serial Attached SCSI) 1.5 Gbps SATA (Serial Advanced Technology Attachment) |
| Architecture |
1.5 Gb SATA | |
| SAS Connectors |
1 internal SFF8484 & 1 external
SFF8470 / internal SFF8484 shared x4 Wide SAS Ports 12 Gbps per x4 Wide SAS Port (4 x 3 Gbps) |
|
| Data Transfer Method |
64-bit wide, PCIX 133 MHz (1 GB/s maximum bandwidth) | |
| PCI Bus Speed | PCIX-133 and 3.3 volt PCI compatibility only | |
| Memory Bus Speed | DDR-266 and 72 bit wide bus | |
| PCI |
64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth) | |
| Simultaneous Drive Transfer Ports | PCI-X and 3.3 volt PCI compatibility only | |
| Port Transfer Rate | 2 x4 Wide SAS Ports | |
| Software upgradeable Firmware |
12 Gb/s per x4 Wide SAS Port (4 x 3 Gb/s) | |
| Cache Memory |
Yes | |
| Logical Drives Supported |
256 MB Read/Write (512-MB module
upgrade available); ECC protection, battery-backed, and removable |
|
| Maximum Capacity |
Up to 32 logical drives Up to 2.2 TB per logical drive |
|
| Memory Addressing |
2.7 TB (38 x 72 GB) 64-bit, supporting servers memory greater than 4 GB |
|
| RAID Support | RAID 6 (Advanced Data Guarding) RAID 5 (Distributed Data Guarding) RAID 1+0 (Striping & Mirroring) RAID 0 (Striping) |
|
| Upgradeable Firmware Disk Drive and |
4-MB flashable ROM | |
| Enclosure Protocol Support | 3 Gb SAS and 1.5 Gb SATA | |
|
|
||
| Embedded NC7782 PCI-X Gigabit Server Adapter |
Network Interface | 10/100/1000-T | |
| Compatibility | EEE 802.3 10Base-T IEEE 802.3ab 1000Base-T IEEE 802.3u 100Base-TX |
||
| Data Transfer Method | 64-bit/66MHz PCI-X | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000 Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP up to 328 ft (100 m) | |
| 10/100/1000 Base-TX | Category 5 UTP up to 328 ft (100 m) | ||
|
|
|||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |