HP ProLiant DL320 Generation 3 (G3)
|
||||||||||||||||||||||
What's New
|
|
|
At
a Glance
|
|
|
Standard Features
| Processor One of the following depending on Model |
Intel Celeron D 2.93 GHz | ||
| Intel Pentium 4 with HT Technology and EM64T 3.4 GHz | |||
| Intel Pentium 4 with HT Technology and EM64T 3.6 GHz (Factory Integrated Only) | |||
|
|
|||
| Processor Cache
One of the following depending on Model |
256KB Level 2 Cache (Celeron D models) | ||
| 1MB Level 2 Cache (Pentium 4 models) | |||
| 2MB Level 2 Cache (Pentium 4 models) | |||
|
|
|||
|
Chipset |
Intel E7221 chipset with 800MHz Front Side Bus (Pentium 4 Models) | ||
| Intel E7221 chipset with 533MHz Front Side Bus (Celeron D Models) | |||
|
|
|||
| Memory Protection |
Advanced ECC |
|
|
|
| Memory One of the following depending on Model |
Type | PC3200 DDR SDRAM running at 400MHz | |
| Standard (Pentium 4 models) |
1 GB (1x 1024 MB) | ||
| Standard (Celeron D models) |
512 MB (1 x 512 MB) | ||
| Maximum | 4 GB | ||
|
|
|||
| Network Controller | Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter | ||
|
|
|||
| Expansion Slots |
Slot Number
|
Bus Speed
|
Height
|
Hot Plug
|
PCI Voltage
|
| PCI-X Non Hot-Plug Riser |
1
|
64-bit/133 MHz PCI-X
|
Full
|
no
|
3.3 Volt
|
|
2
|
64-bit/100 MHz PCI-X
|
Half
|
no
|
3.3 Volt
|
|
| PCI-Express Non Hot-Plug Riser (Optional) |
1
|
PCI Express x4
(x8 connector) |
Full
|
no
|
N/A
|
|
2
|
64-bit/100 MHz PCI-X
|
Half
|
no
|
3.3 Volt
|
|
|
|
|||||
| Storage Controllers | HP embedded 2 Port SATA Controller with RAID 0/1 support. SAS and SCSI controllers available via PCI card. | ||
|
|
|||
| Storage | Diskette Drive | Optional 1.44 MB Diskette Drive option kit is available NOTE: Purchase of floppy drive is required to implement embedded SATA RAID 0/1 with SmartStart 7.2. |
| Optical Drive | Optional CD-ROM, DVD-ROM option kits available NOTE: Purchase of CD-ROM is required for installation of SmartStart. |
|
| Hard Drives | One of the following: (depending on model): | |
|
||
|
||
|
|
||
| Maximum Internal Storage Type | Non-Hot Plug SCSI | 144GB | 2 x 72GB Ultra320 |
| Hot Plug SAS | 292GB | 2 x 146GB SAS | |
| Hot Plug SATA | 1TB | 2 x 500GB Serial ATA | |
| | |||
| Interfaces | Serial | 1 |
| USB 2.0 Ports | 1 front, 1 internal and 2 in rear | |
| NOTE:
Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html | ||
| Graphics | 1 | |
| Keyboard | 1 | |
| Mouse | 1 | |
| Network RJ-45 | 2 | |
| iLO remote management port | 1 | |
|
| ||
| Graphics | Integrated ATI RAGE XL Video Controller with 8-MB SDRAM Video Memory |
|
|
|
| Form Factor | Rack (1U), (1.70 in/4.45 cm) |
|
|
|
|
ProLiant Essentials Foundation Pack Software |
| ||
| |||
| |||
| |||
| |||
| |||
| |||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials | |||
| | |||
| Industry Standard Compliance | ACPI 2.0 |
| PCI 2.2 Compliant | |
| PXE Support | |
| WOL Support | |
| Microsoft® Logo certifications | |
| USB 2.0 | |
|
|
|
| Intelligent Manageability | Automatic Server Recovery (ASR) iLO Advanced Pack (optional) HP Systems Insight Manager Integrated Management Log Drive Parameter Tracking (with Smart Array Controllers) Dynamic Sector Repairing (with Smart Array Controllers) Pre-Failure Warranty (covers processors, SCSI hard drives and memory) |
|
|
|
| Security | Power-on password Keyboard password Diskette drive control Diskette boot control Removable CD-ROM/Diskette Drive Assembly Administrator's password |
|
|
|
| Server Power Cords | One 12' Lowline and one 10' Highline (IEC-IEC) power cord ships standard |
|
|
|
| Power Supply | Auto-sensing 350-Watt PFC Power Supply, CE Mark Compliant |
|
|
|
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable
matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. |
|
|
|
| System Fans | 4 dual rotor fans ship standard. 4 dual rotor fans total supported internally. N+1 (1 rotor only) Redundancy. |
|
|
|
| Ultra Thin Rack Deployment Overview | For the Ultra Thin Rack Deployment Overview, including best practices for the HP ProLiant DL320 G3, please see the following URL: http://www.hp.com/products/servers/ProLiantdl320/. |
| | |
| Required Cabling | For required cabling information, refer to the Web site at: http://www.hp.com/products/servers/ProLiantdl320/. |
| | |
| OS Support | Microsoft Windows 2000 Server Windows Server 2003 (web and standard editions; standard edition for 64-bit extensions) Linux (Red Hat, SuSE, UnitedLinux) VMware Virtualization Software |
| NOTE: Support
differences will exist between the SATA and SCSI configurations. NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix at: http://www.hp.com/go/supportos. NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant DL320, please see: http://h18023.www1.hp.com/support/files/server/us/index.html. NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web site at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html. NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html. |
|
| | |
| Rack Airflow Requirements |
Rack 10000 series Cabinets |
|
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18004.www1.hp.com/products/servers/proliantdl320/index.html. | |
| | |
| HP Factory Express Capabilities |
HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed. Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
|
|
|
| Custom Builder |
Please see the Enterprise Configurator for configuration assistance at: http://www.hp.com/products/configurator. |
|
|
|
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of resellers and service providers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Limited warranty includes
3 year parts, 1 year labor, 1-year on-site support. Care Pack services provide a range of life cycle support options that
let you choose the service levels that meet your business requirements,
from basic to mission-critical. A full range of HP Care Pack hardware and software services are available
including:
HP Care Pack services include coverage for the HP branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. |
| NOTE: For more
information on HP Care Pack services, contact any of our worldwide sales
offices or resellers or visit our worldwide Web site on the internet at:
http://www.hp.com/hps/carepack
NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us at: http://www.hp.com/hps NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html |
|
|
Models
| DL320R03
C2.93-256KB, 512MB 372708-001 | Processor(s) | Intel Celeron D Processor 340J 2.93 GHz |
| Cache Memory | 256KB Level 2 cache | |
| Chipset | Intel E7221 chipset with 533MHz Front Side Bus | |
| Memory | 512 MB (Standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter | |
| Storage Controller | Intel® 82801FR Integrated Serial ATA Host Controller | |
| Hard Drives | None ship standard | |
| Drive Backplane/Cables | None ship standard - See ProLiant DL320 G3 Unique Options below for required hard drive option kits and hard drives. | |
| Internal Storage | 1TB for SATA models, 144GB for SCSI models | |
| Optical Drive | Optional | |
| Diskette Drive | Optional | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
| DL320R03
P3.4-1MB, 1GB 372709-001 | Processor(s) | Intel Pentium 4 Processor 541 with HT Technology and EM64T 3.4 GHz |
| Cache Memory | 1MB Level 2 Cache | |
| Chipset | Intel E7221 chipset with 800MHz Front Side Bus | |
| Memory | 1 GB (standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter | |
| Storage Controller | Intel 82801FR Integrated Serial ATA Host Controller | |
| Hard Drives | None ship standard | |
| Drive Backplane/Cables | None ship standard - See ProLiant DL320 G3 Unique Options below for required hard drive option kits and hard drives. | |
| Internal Storage | 1TB for SATA models, 144GB for SCSI models | |
| Optical Drive | Optional | |
| Diskette Drive | Optional | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
| DL320R03
P3.4-1MB, 1GB, 80GB SATA 370669-001 | Processor(s) | Intel Pentium 4 Processor 541 with HT Technology and EM64T 3.4 GHz |
| Cache Memory | 1MB Level 2 Cache | |
| Chipset | Intel E7221 chipset with 800MHz Front Side Bus | |
| Memory | 1 GB (standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter | |
| Storage Controller | Intel 82801FR Integrated Serial ATA Host Controller | |
| Hard Drives | 80GB SATA HDD | |
| Drive Backplane/Cables | DL320 G3 SAS/SATA HDD Backplane Option Kit | |
| Internal Storage | 1TB for SATA models, 144GB for SCSI models | |
| Optical Drive | Optional | |
| Diskette Drive | Optional | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
| DL320R03
P3.4-2MB, 1GB 372710-001 | Processor(s) | Intel Pentium 4 Processor 650 with HT Technology and EM64T 3.4 GHz |
| Cache Memory | 2MB Level 2 Cache | |
| Chipset | Intel E7221 chipset with 800MHz Front Side Bus | |
| Memory | 1 GB (standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter | |
| Storage Controller | Intel 82801FR Integrated Serial ATA Host Controller | |
| Hard Drives | None ship standard | |
| Drive Backplane/Cables | None ship standard - See ProLiant DL320 G3 Unique Options below for required hard drive option kits and hard drives. | |
| Internal Storage | 1TB for SATA models, 144GB for SCSI models | |
| Optical Drive | Optional | |
| Diskette Drive | Optional | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
| DL320R03
P3.4-2MB, 1GB, 80GB SATA 370670-001 | Processor(s) | Intel Pentium 4 Processor 650 with HT Technology and EM64T 3.4 GHz |
| Cache Memory | 2MB Level 2 Cache | |
| Chipset | Intel E7221 chipset with 800MHz Front Side Bus | |
| Memory | 1 GB (standard) to 4 GB (Maximum) of Advanced ECC PC3200 DDR SDRAM DIMM Memory | |
| Network Controller | Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter | |
| Storage Controller | Intel 82801FR Integrated Serial ATA Host Controller | |
| Hard Drives | 80GB SATA HDD | |
| Drive Backplane/Cables | DL320 G3 SAS/SATA HDD Backplane Option Kit | |
| Internal Storage | 1TB for SATA models, 144GB for SCSI models | |
| Optical Drive | Optional | |
| Diskette Drive | Optional | |
| Form Factor | Rack (1U), (1.75 in/4.45 cm) | |
| | ||
|
|
Configuration Information - Factory Integrated Models
| NOTE:
HP does not allow factory integration of options into standard models listed
above. Configure-to-order servers must start with a CTO Chassis. NOTE: This product offering does not support HP Factory Express Server Configuration Level 1. | |||
| Step 1: Base Configuration (choose one of the following configurable models) | |||
| Models | HP ProLiant DL320G3 SATA Rack CTO Chassis | 374295-405 | |
| Factory Integrated Model ships with: | |||
| Embedded
NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter | |||
| 1 full length/height and 1 half length-low profile 64bit PCI-X slot | |||
| Integrated Lights-Out (iLO) embedded | |||
| DL320 G3 SAS/SATA HDD Backplane Option Kit | |||
| Rack (1U) form factor, (1.75 in/4.45 cm) | |||
| HP ProLiant DL320G3 SCSI Rack CTO Chassis | 383338-405 | ||
| Factory Integrated Model ships with: | |||
| Embedded
NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter | |||
| 1 full length/height and 1 half length-low profile 64bit PCI-X slot | |||
| Non Hot Plug U320 SCSI Option Kit | |||
| Integrated Lights-Out (iLO) embedded | |||
| DL320 G3 Non Hot Plug U320 SCSI Option Kit | |||
| Rack (1U) form factor,
(1.75 in/4.45 cm) | |||
|
| |||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | |||
| Processors | X3.6/PIV/2M DL320G3 FIO ALL |
399664-L21
|
|
| X3.4/PIV/2M DL320G3 FIO Base |
385652-L21
|
||
| X3.6/PIV/1M DL320G3 FIO Base |
374868-L21
|
||
| X3.4/PIV/1M DL320G3 FIO Base |
374867-L21
|
||
| X2.93/CELERON/256KB DL320G3 FIO Base |
374866-L21
|
||
| Base Memory | 512 MB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (1 x 512 MB) |
354560-B21
|
|
| 1024 MB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (1 X 1024 MB) |
354563-B21
|
||
| Optical Drive | HP DVD/CD RW Drive Option (ALL) |
377402-B21
|
|
| DL320G3 CD Drive
NOTE: Required for installation of SmartStart and OS. |
372703-B21
|
||
| DL320G3 DVD-ROM Drive |
374303-B21
|
||
| DL320G3 FLOPPY DRIVE NOTE: Required for installation of SW SATA RAID. |
372702-B21
|
||
|
|
|||
| Step 3: Choose Additional Factory Integratable Options | ||
| Controllers | 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21 |
| HP
8 Internal Port SAS HBA with RAID NOTE: The HP 8 Internal Port SAS/SATA HBA with RAID requires the purchase of the SATA Rack FIO model and the DL320 SAS/SATA Hot Plug Cable option kit (398307-B21) | 347786-B21 | |
| Smart Array 6404/256 Controller | 273914-B21 | |
| Smart Array 6402/128 Controller | 273915-B21 | |
| Smart Array 641 Controller | 291966-B21 | |
| Smart Array 642 Controller | 291967-B21 | |
| Hard Drives | Ultra320 Non-Hot Plug | |
| HP 36GB U320 15K NHP
HDD | 357012-B21 | |
| HP 72GB U320 10K NHP HDD | 332751-B21 | |
| Serial Attached SCSI - SAS | ||
| HP 36GB 3G SAS 15K 3.5" HDD | 375868-B21 | |
| HP 72GB 3G SAS 15K 3.5" HDD | 375870-B21 | |
| HP 146GB 3G SAS 15K 3.5" HDD | 375872-B21 | |
| Serial ATA (SATA) | ||
| HP 80GB 1.5G SATA 7.2K 3.5" HDD | 349237-B21 | |
| HP 160GB 1.5G SATA 7.2K 3.5" HDD | 349238-B21 | |
| HP 250GB 1.5G SATA 7.2K 3.5" HDD | 349239-B21 | |
| HP 500GB 1.5G SATA 7.2K 3.5" HDD | 395473-B21 | |
| NOTE: Please note that Serial ATA hot-plug capability and drive LEDs are not supported by the DL320 G3 embedded SATA storage controller. | ||
| | ||
| Step 4: Choose Additional Options for Factory Integration | |||
| NOTE: For additional options, please refer to the "Options" section below. | |||
|
|
Options
| ProLiant DL320 G3 Unique Options | HP
ProLiant DL320 G3/G4 PCI Option Kit
The PCI riser board assembly supports an optional full-length PCI Express riser board in place of the full-length PCI-X riser board. | 417135-B21 | |
| PCI-X/PCI-EXPRESS RISER | 374281-B21 | ||
| Floppy Drive Option Kit | 372702-B21 | ||
| HP DVD/CD RW Drive Option (ALL) | 377402-B21 | ||
| DVD ROM Drive Option |
374303-B21 | ||
| CD ROM Drive Option | 372703-B21 | ||
| DL320 Hot Plug SAS/SATA
Cable Option Kit NOTE: This option is required for the HP 8 int. Port SAS/SATA HBA with RAID. This option with the addition of the DL320G3 SAS/SATA HDD Backplane Option Kit and the HP 8 int. Port SAS/SATA HBA with RAID enables the DL320 G3 for Hot Plug and LED drive support. | 398307-B21 | ||
| DL320 G3 SAS/SATA
HDD Backplane Option Kit NOTE: This option is required on the non-hard drive models for any supported SATA HDD options. | 372704-B21 | ||
| DL320 G3 Non Hot
Plug U320 SCSI Option Kit NOTE: This option is required for use with any supported non Hot Plug U320 SCSI HDD options. A PCI controller is also required; please see Storage Controllers below for U320 controller options. |
374282-B21 | ||
|
| |||
| ProLiant
Essentials Value Pack Software |
ProLiant Essentials Integrated Lights-Out Advanced Pack | ||
| ProLiant Essentials
Integrated Lights-Out Advanced Pack, 1 server Featuring: sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites. |
263825-B21
|
||
| NOTE: For additional ProLiant Integrated Light-Out Advanced Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11052_na/11052_na.html | |||
| ProLiant Essentials Intelligent Networking Pack | |||
| ProLiant Essentials
Intelligent Networking Pack, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372906-B21
|
||
| NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_na/12062_na.html | |||
| ProLiant Essentials Intelligent Networking Pack - Linux Edition, Single Server License |
397004-B21
|
||
| NOTE:
For additional ProLiant Intelligent Networking Pack - Linux License Kits
please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_na/12327_na.html |
|||
| ProLiant Essentials Performance Management Pack | |||
| ProLiant Essentials
Performance Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation. NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp. |
306696-B21
|
||
| NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_na/11925_na.html | |||
| ProLiant Essentials Rapid Deployment Pack Windows Edition Release | |||
| Rapid Deployment
Pack, Single-Server License NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-B21
|
||
| NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html | |||
| ProLiant Essentials Workload Management Pack | |||
| ProLiant Essentials Workload Management Pack, Single Server License |
303284-B21
|
||
| NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_na/11452_na.html | |||
| ProLiant Essentials Virtualization Management Software | |||
| ProLiant Essentials
Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
372214-B21
|
||
| ProLiant
Essentials Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. |
|||
| NOTE: For additional ProLiant Essentials Virtualization Management Software License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.html | |||
| ProLiant Essentials Vulnerability and Patch Management Pack | |||
| ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
371645-B21
|
||
| NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_na/12111_na.html | |||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant
Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
|||
|
|
|||
|
Memory (DIMMs) |
1024 MB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (1 x 1024 MB) |
354563-B21 |
| 512 MB of Advanced ECC PC3200 DDR SDRAM DIMM Memory Kit (1 x 512 MB) |
354560-B21 | |
|
| ||
|
Internal Storage |
CD-ROM Drive Assembly Option Kit |
372703-B21
|
| Floppy Drive Assembly Option kit |
372702-B21
|
|
| DVD-ROM Drive Assembly Option Kit |
374303-B21
|
|
| HP DVD/CD RW Drive Option |
377402-B21
|
|
| DL320 G3 Non Hot Plug U320 SCSI Option Kit |
374282-B21
|
|
| DL320 G3 SAS/SATA HDD Backplane
Option Kit NOTE: When adding either SATA or U320 SCSI drives to a non-hard drive DL320 G3 model, the appropriate option kit above is required for operation. |
372704-B21
|
|
|
|
||
| Hard Drives | Ultra320 - Universal Non-Hot Plug | |
| HP 72GB U320 10K NHP HDD | 332751-B21 | |
| HP 36GB U320 15K NHP HDD | 357012-B21 | |
| NOTE: All U320
Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives
require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320
transfer rates. NOTE: Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html | ||
| Serial Attached SCSI - SAS | ||
| HP 146GB 3G SAS 15K 3.5" HDD | 375872-B21 | |
| HP 72GB 3G SAS 15K 3.5" HDD | 375870-B21 | |
| HP 36GB 3G SAS 15K 3.5" HDD | 375868-B21 | |
| NOTE:
Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration, and
operating temperature: http://h18000.www1.hp.com/products/quickspecs/12244_na/12244_na.html | ||
| Serial ATA (SATA) | ||
| HP 500GB 1.5G SATA 7.2K 3.5" HDD | 395473-B21 | |
| HP 250GB 1.5G SATA 7.2K 3.5" HDD | 349239-B21 | |
| HP 160GB 1.5G SATA 7.2K 3.5" HDD | 349238-B21 | |
| HP 80GB 1.5G SATA 7.2K 3.5" HDD |
349237-B21 | |
| NOTE:
Please note that Serial ATA hot-plug capability and drive LEDs are not supported
by the DL320 G3 embedded SATA storage controller. The purchase of the HP
8 Internal Port SAS HBA with RAID, the DL320 G3 SAS/SATA HDD Backplane Option
Kit, and the DL320 Hot Plug SAS/SATA Cable Option Kit is required for Hot
Plug and LED SAS/SATA support. NOTE: SATA drives have a 1-year warranty. Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/11940_na/11940_na.html | ||
| | ||
| Storage Controllers | 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21 |
| HP
8 Internal Port SAS HBA with RAID NOTE: The HP 8 int. Port SAS/SATA HBA with RAID requires the purchase of the SATA Rack FIO model and the DL320 SAS/SATA Hot Plug Cable option kit (398307-B21). | 347786-B21 | |
| Smart Array 6404/256 Controller |
273914-B21 | |
| Smart Array 6402/128 Controller | 273915-B21 | |
| 512MB DDR BBWC Upgrade | 372538-B21 | |
| Smart Array 641 Controller |
291966-B21 | |
| Smart Array 642 Controller | 291967-B21 | |
| 128MB BBWC for SA641/642 NOTE: This 128 MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller. |
351580-B21 | |
| 64-Bit/133-MHz
Dual Channel Ultra320 SCSI Adapter NOTE: Supports Wide Ultra3, Ultra320 SCSI drives only. |
268351-B21 | |
|
NOTE: Please see the following
Controller or SCSI Adapter QuickSpecs for Technical Specifications such
as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI
Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache,
RAID support, and additional information: | ||
|
| ||
|
Communications |
HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter |
367132-B21
|
| HP NC310F PCI-X 1000SX Gigabit Server Adapter |
368169-B21
|
|
| HP NC320T PCI Express 1000T Gigabit Server Adapter |
367047-B21
|
|
| HP NC370F PCI-X Multifunction 1000SX Gigabit Server Adapter |
374193-B22
|
|
| HP NC370T PCI-X Multifunction 1000T Gigabit Server Adapter |
374191-B22
|
|
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21
|
|
| HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter |
394795-B21
|
|
| HP NC1020 PCI 1000T Gigabit Server Adapter |
353377-B21
|
|
| HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter |
313881-B21
|
|
| HP NC7170 PCI-X Dual Port Low Profile 1000T Gigabit Server Adapter |
383738-B21
|
|
| HP NC7771 PCI-X 1000T Gigabit Server Adapter |
290563-B21
|
|
| NOTE: A minimum
of 1 GB of memory per port is required for NC370x adapters, with a maximum
of two NC370x ports permitted in a server. NOTE: Any NC61XX, NC71XX or NC77XX network adapter can be used for redundancy with the embedded NC7782 network adapter. |
||
| HP NC570C PCI-X Dual-port 4x Fabric Adapter |
376158-B21
|
|
| HP NC571C PCI Express Dual-port 4x Fabric Adapter |
376160-B21
|
|
| HP 24-Port 4x Fabric Copper Switch |
376227-B21
|
|
| HP 4x Fabric 1m Copper Cable |
376232-B21
|
|
| HP 4x Fabric 3m Copper Cable |
376232-B22
|
|
| HP 4x Fabric 5m Copper Cable |
376232-B23
|
|
|
Tape Drives |
|
||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||
|
Tape Autoloaders |
|
|||||||||||||||||||
|
| ||||||||||||||||||||
| Tape Libraries |
| |||||||||||||||||||||||||||||||||||||||||||
|
| ||||||||||||||||||||||||||||||||||||||||||||
|
Magento-Optical Jukeboxes | HP StorageWorks 9.1 GB Entry-level Optical Storage | |
| 600mx, 4 drive, 64 slot jukebox |
C1160M
|
|
| 1200mx, 4 drive, up to 128 slots |
C1104M
|
|
| 2200mx, 6 drive, up to 238 slots |
C1107M
|
|
| NOTE: Please see
the HP StorageWorks Magneto-Optical Products data sheet for a complete listing
of available jukeboxes at: http://www.hp.com/products1/storage/products/archivalprod/brochures/ MO_family_pb.pdf NOTE: Please reference the Magneto-Optical Jukebox data sheets at http://www.hp.com/go/optical for additional information needed to create a complete solution. |
||
|
| ||
|
HP Data Protector Express Software | HP DP Express Backup Server Upgrade for ProLiant Software | BB117AP |
| HP DP Express Package for Microsoft Small Business Server | BB118AA | |
| NOTE: Please
see the HP Data Protector Express QuickSpecs for additional information regarding
the purchase of HP Data Protector Express software: http://h18000.www1.hp.com/products/quickspecs/12337_na/12337_na.html | ||
| | ||
|
HP StorageWorks Modular Smart Array 20 |
HP StorageWorks Modular Smart
Array 20 NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. |
335921-B21
|
| HP StorageWorks Modular Smart
Array 20 Starter Kit NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller. |
366172-B21
|
|
| NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 3.5" Hot Plug Hard Drives. |
|
|
HP StorageWorks Modular Smart Array 30 |
HP StorageWorks Modular Smart
Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies |
302969-B21
|
| HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies |
302970-B21
|
|
| NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 Hot Plug Hard Drives. |
|
|
HP StorageWorks Modular Smart Array 500 |
HP StorageWorks Modular Smart Array 500 Generation 2 |
335880-B21
|
| NOTE: Please see
the Modular Smart Array 500 Generation 2 QuickSpecs for additional information
including configuration steps and additional options needed for a complete
solution at: http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.html |
|
|
HP StorageWorks Modular Smart Array 1000 |
HP StorageWorks Modular Smart Array 1000 |
201723-B22
|
| NOTE:
Please see the Modular Smart Array 1000 QuickSpecs for additional options
and configuration information at http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html |
|
|
HP StorageWorks Modular Smart Array 1500 cs |
Modular Smart Array 1500 Controller
Shelf |
AA986A
|
| NOTE: Please see
the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options
and configuration information at: http://www.hp.com/go/MSA1500cs |
|
|
StorageWorks Options |
StorageWorks 2 Gb, 64-bit/133
MHz PCI-X-to-Fibre Channel Host Bus Adapter for Windows 2000, Windows Server
2003 and Linux NOTE: FCA2214 2 Gb Fibre Channel Host Bus Adapter is a single channel, 64-bit/133 MHz PCI-X-to Fibre Channel Host Bus Adapter (HBA) with an embedded multi-mode optical interface. |
281541-B21
|
| FCA2408 - HP StorageWorks 2 Gb,
64-Bit/133 MHz Single Channel, PCI- X-to-Fibre Channel Host Bus Adapter
for Windows® 2000 and Windows Server® 2003 NOTE: FCA2408 HP StorageWorks 2 Gb, 133 MHz PCI-X-to-Fibre Channel Host Bus Adapter (HBA) with optical small-form-factor (SFF) (LC) interface. |
343073-B21 | |
| FCA2404DC - HP StorageWorks 2
Gb, Dual Channel, 133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for Windows
2000, and Windows Server 2003 NOTE: FCA2404DC HP StorageWorks 2 Gb Fibre Channel Host Bus Adapter is a dual channel, 133 MHz, PCI-X to Fibre Channel Host Bus Adapter (HBA) with an embedded multi-mode optical interface. |
323264-B21 | |
| FCA2404 - StorageWorks 2 Gb, single
channel, 133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for Windows 2000,
Windows NT and Windows Server 2003 NOTE: FCA2404 StorageWorks 2 Gb, Fibre Channel Host Bus Adapter is a single channel, multi-path failover, 133 MHz, PCI-X to Fibre Channel Host Bus Adapter (HBA) with an embedded multi-mode optical interface for Proliant Server connects. |
305573-B21 | |
| StorageWorks 2 Gb, Dual Port,
64-Bit/133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for W2K, Windows
Server 2003 and Linux NOTE: FCA2214DC StorageWorks 2 Gb Dual Port, Fibre Channel Host Bus Adapter is a 64-bit/133 MHz, PCI-X-to Fibre Channel Host Bus Adapter (HBA) with an embedded multi-mode optical interface. |
321835-B21 | |
|
| ||
|
Uninterruptible Power Systems Rack UPS |
HP UPS R5500 XR, (5000VA, 4500
Watt), High Voltage |
326529-D71
|
| HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage |
204404-001 |
|
|
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage |
192186-001 |
|
|
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage |
192186-002 |
|
| HP UPS R5500 XR, (5000VA, 4500 Watt), High Voltage |
326529-D71
|
|
| HP
UPS R12000 XR, N+ x (12KVA, 12KW) High Voltage NOTE: The UPS R12000 XR has a hardwired input and output connection. |
207552-B22
|
|
|
|
||
| USB Options | USB Optical Scroll Mouse (Carbonite) | DD441B | ||
| USB 1.44-MB External Diskette Drive (Carbonite) | DC141B | |||
| 256MB HP Drive Key II (USB 2.0) | PH657A | |||
|
|
||||
|
ProLiant DL320 Deployment Options |
Rack Adapter Kit NOTE: This kit allows HP rack servers to fit in racks that are 24" wide. |
332815-B21 |
| NOTE: Telco Rack Support - Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions: http://www.racksolutions.com/hp |
|
| HP
Rack 5000 Series (Graphite Metallic) | HP
5642 Rack-Unassembled | 358254-B21 |
| NOTE:
Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical
Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.html (Worldwide) NOTE: For additional information regarding Rack Cabinets, please see the following URL: www.hp.com/go/rackandpower. | |
|
HP Rack 10000 G2 Series |
10642 G2 (42U) Rack Cabinet - Pallet |
AF001A
|
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A
|
|
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A
|
|
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet |
AF004A
|
|
| 10642 G2 (42U) Rack Cabinet, without door - Shock Pallet |
AF005A
|
|
| 10642 G2 (42U) Rack Cabinet - with Extension, without door - Shock Pallet |
AF006A
|
|
| 10636 G2 (36U) Rack Cabinet - Pallet |
AF011A
|
|
| 10636 G2 (36U) Rack Cabinet - Shock Pallet |
AF012A
|
|
| 10636 G2 (36U) Rack Cabinet - Crated |
AF013A
|
|
| 10636 G2 (36U) Rack Cabinet , with Extension - Shock Pallet |
AF014A
|
|
| 10636 G2 (36U) Rack Cabinet, without door - Shock Pallet |
AF015A
|
|
| 10636 G2 (36U) Rack Cabinet, with Extension, without door - Shock Pallet |
AF016A
|
|
| NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. | ||
| NOTE: Please see
the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
| ||
|
HP Rack 10000 Series (Graphite Metallic) | 10642 (42U) Infrastructure Rack (Low Voltage) |
379006-001 |
| 10642 (42U) Infrastructure Rack (High Voltage) |
379005-001 | |
| HP S10614 (14U) Rack Cabinet Shock Pallet |
292302-B22 | |
|
HP 10842 (42U, 800mm wide) Rack Cabinet Pallet |
257415-B21 | |
|
HP 10842 (42U, 800mm wide) Rack Cabinet Shock Pallet |
257415-B22 | |
|
HP 10647 (47U) Rack Cabinet Pallet |
245160-B21 | |
|
HP 10647 (47U) Rack Cabinet Shock Pallet |
245160-B23 | |
|
HP 10642 (42U) Rack Cabinet Pallet |
245161-B21 | |
| HP 10642 (42U) Rack Cabinet Shock Pallet |
245161-B22 | |
| HP 10642 (42U) Rack Cabinet Crated |
245161-B23 | |
| HP 10636 (36U) Rack Cabinet Pallet |
245162-B21 | |
| HP 10636 (36U) Rack Cabinet Shock Pallet |
245162-B22 | |
| HP 10636 (36U) Rack Cabinet Crated |
245162-B23 | |
| HP 10622 (22U) Rack Cabinet Pallet |
245163-B21 | |
| HP 10622 (22U) Rack Cabinet Shock Pallet |
245163-B22 | |
| HP 10622 (22U) Rack Cabinet Crated |
245163-B23 | |
| NOTE: xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). xxxxxx-B23 (crated) used for air shipments of empty racks. | ||
| NOTE: Please
see the Rack 10000 QuickSpecs for Technical Specifications such as height, width,
depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower | |
|
Rack Options for HP | TFT7210R
Rack Mounted 17" Monitor NOTE: For a complete list of Monitors please view the following URL: http://www.hp.com/go/kvm | 348373-B21 |
| TFT7600RKM | AG052A | |
| 1U Rack Keyboard & Drawer (Carbon) | 257054-001 | |
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower | ||
| | ||
|
HP KVM Switch Options |
IP Console Switch Box (KVM/IP), 3 x 1 x 16 |
262586-B21
|
| IP Console Switch Box (KVM/IP), 1 x 1 x 16 |
262585-B21
|
|
| Server Console Switch (KVM), 0 x 1 x 8 port |
336044-B21
|
|
| Server Console Switch (KVM), 0 x 2 x 16 port |
336045-B21
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| USB Interface Adapter, 1 pack |
336047-B21
|
|
| Serial Interface adapter - 1 Pack with power supply |
373035-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x 4 USB/PS2 KVM Switch, TT |
371301-D71
|
|
| HP 1x 4 USB/PS2 KVM Switch, RM |
371302-B21
|
|
| HP PS2 KVM Cable with audio, 6', 2-pack |
371730-B21
|
|
| HP USB KVM Cable with audio, 6', 2-pack |
371729-B21
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
|
HP Serial Console Server Options |
HP 16 Port Serial Console Server |
AF101A
|
| HP 48 Port Serial Console Server |
AF102A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A
|
|
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
|
Service and Support Offerings (HP Care Pack Services) |
Hardware Services On-site Service | |
| Next Business Day On-site Service, 5-Day x 9-Hour Coverage, 3 Years, Electronic |
U4479E
|
|
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic |
U4480E
|
|
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4481E
|
|
| 6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4482E
|
|
| Installation & Start-up Services | ||
| Hardware Installation, Electronic |
U4490E
|
|
| Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays, Electronic |
U4491E
|
|
| Support Plus | ||
| Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic |
U4492E
|
|
| Support Plus 24 | ||
| Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4493E
|
|
| Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic. |
U6309E
|
|
| Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic. |
U8331E
|
|
| NOTE: For more information, customer/resellers can contact http://www.hp.com/hps/ |
|
|
Memory
|
HP ProLiant DL320 G3 All Models |
|
Standard Memory Standard Memory Plus Optional Memory |
| NOTE: The chart below represents the P4 models with 1GB standard memory, and does not represent all possible configurations. Memory can be populated in any order with any of the supported DIMMs listed. For optimal performance, the total amount of memory in slots 1A and 2A should equal to the total amount of memory in slots 3B and 4B. |
|
Memory |
Slot |
||||
|
|
1A |
2A |
3B |
4B |
|
|
Standard |
1024 MB
|
1024 MB |
Empty |
Empty |
Empty |
|
Optional
|
2048 MB
|
512 MB |
512 MB |
512 MB |
512 MB |
|
Maximum |
4096 MB
|
1024 MB |
1024 MB |
1024 MB |
1024 MB |
|
Following are memory options available from HP: |
|
|
354563-B21 |
|
354560-B21 |
|
|
Storage
![]() |
1- 2 | Two SATA or SCSI non-hot plug drive bays |
| A | Removable 1.44 MB Diskette Drive Assembly Kit | |
| B | Optional CD-ROM/DVD Drive Assembly Kit | |
|
Drive Support |
|||
|
Quantity |
Position |
|
|
|
Removable Media |
|||
|
1.44-MB Diskette Drive |
Up to 1 |
A |
Integrated |
| Low-profile IDE (ATAPI) CD-ROM Drive | Up to 1 | B | Integrated IDE (ATAPI) |
|
Low-profile IDE DVD-ROM Drive |
Up to 1 |
B |
Integrated IDE |
|
|
|||
|
Hard Drives |
|||
| Ultra320 SCSI Non-Hot Plug Drives | |||
|
Quantity |
Position |
|
|
| 36.4GB U320 15K 72.8GB U320 15K |
Up to 2 |
1-2 |
Smart Array 6402/128 Controller |
| SAS Drives | |||
| Quantity Supported |
Position Supported |
Controller | |
| 36GB 3G SAS 15K 72GB 3G SAS 15K 146GB 3G SAS 15K |
Up to 2 | 1-2 | HP 8 Internal Port SAS HBA with RAID |
|
|
|||
| Serial ATA Drives | |||
|
Quantity Supported |
Position Supported |
Controller |
|
| 80GB 1.5G SATA 7.2K 160GB 1.5G SATA 7.2K 250GB 1.5G SATA 7.2K 500GB 1.5G SATA 7.2K |
Up to 2 | 1-2 | HP embedded 2 Port SATA Controller with RAID 0/1 support |
|
|
|||
|
External Storage |
||||
|
Quantity |
Position |
|
||
| Modular Smart Array 20 |
Please see the Modular Smart Array 20 QuickSpecs below
to determine configuration requirements
|
External
|
Please see the Modular Smart Array 20 QuickSpecs below see the list of supported controllers | |
|
Modular Smart Array 30 Family |
Up to 14 |
External |
Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller 64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
|
| Modular Smart Array 500 G2 |
1
|
External
|
Please see the Modular Smart Array 500 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/msa500 | |
| Modular Smart Array 1000 |
Please see the Modular Smart Array 1000 QuickSpecs below
to determine configuration requirements
|
External
|
Please see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of supported HBAs | |
| Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html | ||||
|
|
||||
| Maximum Storage Capacity - (Enclosure with SCSI models) | |
| Internal | 145GB (2 x 72GB SCSI) |
| External | 4.20TB (1 x (14 x 300GB Ultra320)) |
| Total | 4.35TB |
| NOTE: In order to implement integrated SATA RAID with Smart Start 7.2, purchase of floppy drive is required. | |
|
| |
| Maximum Storage Capacity - (SATA Enclosure with SATA models) | |
| Internal | 1TB (2 x 500GB SATA) |
| External | 6.00TB (1 x (12 x 500GB SATA Drives)) |
| Total | 7.00TB |
| NOTE: In order to implement integrated SATA RAID with Smart Start 7.2, purchase of floppy drive is required. | |
| NOTE: The External capacity section relates to the HP StorageWorks Modular Smart Array 20. | |
|
|
|
| Tape Drives, Tape Autoloaders & Tape Libraries | |||
|
NOTE: For an up-to-date listing of the latest
O/S Support details for each of the Tape Drives listed below, please see the following: NOTE: For an up-to-date listing of
the latest O/S Support details for each of the Tape Autoloaders & Tape Libraries
listed below, please see the following: NOTE: For complete listing of tape drive offerings see http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html For details on connecting tape drives to this server, see the following: | |||
| Quantity Supported | Position
Supported |
Controller | |
|
HP StorageWorks Tape Drives, USB External | 1
per USB port | External | USB port |
| HP StorageWorks Tape Drives,
External Ultrium 232 Ultrium 448 Ultrium 460 DAT 40 DAT 72 DLT VS80 DLT VS160 SDLT 320 |
Up to 2 |
External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
| HP StorageWorks Tape Drives,
External Ultrium 960 SDLT 600 |
1 per SCSI Channel |
External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
| HP StorageWorks Autoloaders,
External DAT 72x6 Tape Autoloader 1/8 Tape Autoloader |
1 autoloader per SCSI channel |
External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
| HP StorageWorks Rack-mount
Tape Drive Enclosures 1U Rack-Mount Kit 3U Rack-Mount Kit 5U Rack-Mount Kit | 1 per
SCSI channel | External | 64-Bit/133MHz
Dual Channel Ultra320 SCSI Adapter 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS |
| HP StorageWorks Tape Libraries,
External MSL2024 (Ultrium 448 and 960-based) MSL4048 (Ultrium 448 and 960-based) MSL6000 (Ultrium 960 and 460-based) MSL6000 (SDLT 600-based) MSL5026S2 (SDLT 320-based) MSL5052S2 (SDLT 320-based) |
Please reference the MSL Tape Library QuickSpecs to determine
configuration requirements |
External | Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs for detailed connectivity information. |
|
|
Technical Specifications
|
System Unit |
Dimensions (HxWxD) |
1.70 x 16.78 x 24.0 in (4.32 x 42.62 x 60.96 cm) |
|
|
Weight (no drives installed) |
24.0 lb (10.91 kg) |
||
|
Weight (fully configured with two hard drives, four DIMM modules, and a PCI expansion board) |
27.0 lb (12.27 kg) | ||
|
Input Requirements |
Range Line Voltage |
90 to 264 VAC |
|
|
Nominal Line Voltage |
100 to 120 VAC/220 to 240 VAC |
||
|
Rated Input Current |
6 A (100 to120 VAC) to |
||
|
Rated Input Frequency |
47 to 63 Hz |
||
| Rated Input Power | @ 115V input, Rated input power
= 486W (assume output wattage=350W) @ 230V input, Rated input power = 479W (assume output wattage=350W) |
||
|
Power Supply Output |
Steady State Power |
350 W (rated) |
|
| Environmental Operating | |||
| Operating | Ambient Temperature | 50° to 95° F (10° to 35° C) | |
|
Temperature Derating |
1.8° F per 1000 ft to 10,000 ft |
||
|
Relative Humidity |
10% to 90% (non-condensing) |
||
|
Maximum wet bulb temperature |
82° F (28° C) |
||
| Non-operating Storage | Temperature | -22° to 140° F (-30 to 60° C) | |
| Relative Humidity | 5% to 95% (non-condensing) | ||
| Maximum wet bulb temperature | 102° F (38.7° C) | ||
| Non-operating Shipping | Temperature | -22° to 140° F (-30 to 60° C) | |
| Relative Humidity | 5% to 95% (non-condensing) | ||
| Maximum wet bulb temperature | 102° F (38.7° C) | ||
|
Acoustic Noise |
Idle at 23 degree C ambient |
||
|
≤6.4 |
||
|
≤47 |
||
|
Operating |
|||
|
≤6.4 |
||
Bystander L pAm (dBA) |
≤47 |
||
|
|
|||
|
Serial ATA Hard Drives |
80 GB 7.2K |
Capacity |
80,000 MB | |
| 349237-B21 | Height | 1.028 in/2.611cm | ||
| Width | 4.0 in (10.16 cm) | |||
| Interface | Serial ATA | |||
| Transfer Rate Synchronous (Maximum) |
1.5 Gb/s | |||
| Seek Time (typical reads, including settling) |
Single Track | 0.9 ms | ||
| Average | 9.0 ms | |||
| Full-Stroke | 17.0 ms | |||
| Rotational Speed | 7,200 rpm | |||
| Physical Configuration | Bytes/Sector | 512 | ||
| Logical Blocks | 156,301,488 | |||
| Operating Temperature | 41° to 131° F (5° to 55° C) | |||
|
|
||||
|
Power Supply |
Input voltage specifications |
Rated input voltage |
100 VAC to 240 VAC |
|
Input Specifications |
Rated input line |
90 VAC to 264VAC |
|
|
Frequency range |
47 to 63 Hz |
||
|
Rated input power |
@ 115V input, Rated input power = 486W (assume output wattage=350W |
||
|
Rated input current |
6 A, 3 A (110 V, 220 V) |
||
|
Steady state power |
350W (rated) |
||
| BTU Rating | 1710 BTU/hr | ||
| Ambient temperature range | Operating | 50° to 118° F (10° to 48° C) | |
| Non-operating | -40° to 158° F (-40° to 70° C) | ||
|
Relative humidity |
Operating |
55% to 85% | |
| Non-operating | 5% to 95% | ||
| Dielectric voltage withstand | Input to output | 1800 VAC/minute | |
| Input to ground | 1800 VAC/minute | ||
| Maximum Wet Bulb Temperature | 41.3C | ||
|
|
|||
|
Embedded NC7782 Dual Port NIC |
Network Interface | 10Base-T/ 100Base-TX/ 1000Base-TX |
|
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| Data Transfer Method | 64-bit/100MHz PCIX | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) |
2000Mb/s | ||
| Connector | RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 10/100/1000Base-TX | Category 5 UTP; up to 328 ft (100 m) | ||
|
| |||
|
Integrated Dual Channel Serial ATA Controller |
Simultaneous drive transfer channels |
2 channels | |
| Transfer rate synchronous (maximum theoretical) | 150 MB/s per channel; 300MB/s in RAID 0 pair | ||
| Data transfer method |
Intel® 82801FR Integrated
Serial ATA Host Controller (non-RAID mode) Intel® 82801FR Integrated Serial ATA Host Controller (RAID Mode) |
||
| Drive support |
Serial ATA | ||
| Data transfer modes | Legacy Mode Combined Mode |
||
| Protocol | Serial ATA | ||
| Feature | NCQ (Native Command Queuing);AHCI (Advanced Host Controller Interface) | ||
|
|
|||
|
Integrated Serial ATA Controller |
Transfer rate synchronous (maximum) |
150 MB/s per channel; 300MB/s in RAID 0 pair | |
| Protocol |
Serial ATA | ||
| Drive support |
HP Universal Serial ATA | ||
| Data transfer modes |
ATA data-transfer modes
supported SATA 1.0, SATA II PIO modes 0-4 Multiword DMA modes 0-2 Ultra DMA modes 0-6 |
||
| RAID levels |
0, 1 | ||
| Feature |
Supports Pre-Failure
Warranty of SATA Hard Drives Support for Systems Insight Manager Supports multiple logical volumes Setup through ROM based Array Configuration Utility Installation scripting support |
||
| OS Support |
Microsoft Windows 2000
Server Microsoft Windows Server 2003 Novell NetWare Linux (Red Hat, SuSE, UnitedLinux) |
||
| NOTE: This controller
does not support LED functions This controller does not support Hot Plug functions |
|||
|
|
|||
| ©
Copyright 2006 Hewlett-Packard Development Company, L.P. The
information contained herein is subject to change without notice. Microsoft
and Windows NT are US registered trademarks of Microsoft Corporation. Intel is
a US registered trademark of Intel Corporation. The
only warranties for HP products and services are set forth in the express warranty
statements accompanying such products and services. Nothing herein should be construed
as constituting an additional warranty. HP shall not be liable for technical or
editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |