|
|
Overview
| HP ProLiant ML570 Generation 3 (G3)
| |||||||||||||||||
|
||||||||||||||
|
What's New
|
|
|
|
At A Glance The HP ProLiant ML570 G3 server is the industry's first 4 processor expansion server that offers not only exceptional performance, but increased reliability with hot-plug RAID memory, powerful management capabilities, and unmatched internal expansion. With expansion capabilities featuring up to 64GB
max memory, support for up to 10×1" hot-plug Ultra 320 SCSI
hard drives or 18 Small Form Factor (SFF) SAS drives, and up to 10 PCI
I/O slots, the ProLiant ML570 G3 is a truly expandable and reliable server
for a data center or remote enterprise environment. The ML570 G3 now supports
Intel's new Xeon dual core processor technology providing performance
gains for multi-threaded applications, for example database, financial
services, and supply-chain management.
|
|
|
Standard Features
| Processor One of the following depending on Model |
Dual-core Intel Xeon Processor at 3.00 GHz\2x2MB |
| Intel Xeon Processor at 3.33 GHz\8MB | |
| Intel Xeon Processor at 3.00 GHz\8MB | |
| Dual-core Intel Xeon Processor at 2.66 GHz\2x1MB | |
| Intel Xeon Processor at 2.83 GHz\4MB | |
| Intel Xeon Processor at 3.66 GHz\1MB | |
| Intel Xeon Processor at 3.16 GHz\1MB | |
| NOTE: 2P models ship standard with two processors while all other models ship with one processor as standard. | |
| | |
| Cache
Memory One of the following depending on Model |
8MB Integrated Level 3 cache
(per processor) NOTE: Available with 3.33 GHz, 3.00 GHz models only. |
| 4MB Integrated Level 3 cache NOTE: 2.83 GHz Model only. |
|
| 2x2MB Integrated Level 2 cache NOTE: Dual-core 3.00 GHz Model only. |
|
| 2x1MB Integrated Level 2 cache NOTE: Dual-core 2.66 GHz Model only. |
|
| 1MB Integrated Level 2 cache NOTE: 3.66 GHz, 3.16 GHz Models only. |
|
|
|
|
| Upgradeability | Upgradeable to quad processing |
| | |
| Chipset | Intel E8500 chipset |
| NOTE: For more
information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/. |
|
| | |
| Memory Protection |
Advanced ECC |
| Hot-Plug RAID Memory | |
| Hot-Plug Mirrored Memory | |
| Online Spare Memory | |
|
|
|
| Memory | Type | PC2-3200R MHz Registered ECC SDRAM DIMM Memory | |
| Standard (2P models) | 2048 MB (4 x 512 MB) | ||
| Standard (base models) | 1024 MB (2 x 512 MB) | ||
| Maximum | 64 GB | ||
| NOTE:
For more information regarding Advanced Memory Protection, please see the
following URL: http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html. | |||
| | |||
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter |
| | |
|
Expansion Slots
|
Slot
Number |
Bus Speed
|
Bus Number*
|
Device Number**
|
Hot Plug
|
PCI Voltage
|
Notes
|
|
1
|
64-bit/100MHz PCI-X
|
7
|
1
|
no
|
3.3 Volt
|
||
|
2
|
64-bit/100MHz PCI-X
|
7
|
2
|
no
|
3.3 Volt
|
||
|
3
|
64-bit/100MHz PCI-X
|
3
|
1
|
no
|
3.3 Volt
|
||
|
4
|
64-bit/100MHz PCI-X
|
3
|
2
|
no
|
3.3 Volt
|
Supported RILOE slot
|
|
|
5
|
PCI Express x4
|
11
|
1
|
no
|
N/A
|
||
|
6
|
PCI Express x4
|
14
|
1
|
no
|
N/A
|
||
|
7
|
PCI Express x4
|
17
|
1
|
no
|
N/A
|
||
|
8
|
PCI Express x4
|
20
|
1
|
no
|
N/A
|
||
|
9
|
64-bit/133MHz PCI-X
|
27
|
1
|
yes
|
3.3 Volt
|
Recommended Smart Array P600 Controller slot
|
|
|
10
|
64-bit/133MHz PCI-X
|
24
|
1
|
yes
|
3.3 Volt
|
||
| NOTES: *Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number. **Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID by bus (starting with the lowest bus). |
|||||||
| NOTE: All PCI-X slots can only accept universal keyed PCI cards running at 3.3 volts. | |||||||
| NOTE: x8 PCI-Express cards are supported in all PCI-Express slots but will run at x4 speeds. | |||||||
|
|
|||||||
|
Storage Controllers |
Integrated Dual Channel Ultra320 SCSI Adapter |
| HP Smart Array P600/256 BBWC
Controller (standard in SAS models) NOTE: For SAS/SATA drives and integrated Dual Channel Ultra320 SCSI Adapter can be used for tape drive in removable media bay or external storage support. |
|
|
|
|
| Storage | Diskette Drives | 1.44 MB Slimline Drive (optional) |
| Optical Drive | 8x/24x IDE (ATAPI) Slimline DVD-ROM Drive | |
| Hard Drives | None | |
|
|
||
| Maximum Internal Storage Type | Hot Plug SCSI | 3.0TB | 8 x 300GB + 2 x 300GB Ultra320 |
| Hot Plug SAS | 2.628TB | 18 x 146GB SFF SAS | |
| | |||
| Interfaces | Parallel | 1 |
| Serial | 1 | |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard | 1 | |
| iLO |
1 | |
| USB Ports | 3 Total: 1 front; 2 rear NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html |
|
| Network RJ-45 | 2 | |
| External SCSI | 1 | |
|
|
||
| Graphics | Integrated ATI RAGE XL Video Controller with 8MB Video Memory |
|
|
|
| Form Factor | Tower or Rack (6U) |
|
|
|
| Product Demo | To view the Product Demo,
please see the following URL, then click on "PRODUCT TOUR": http://h18004.www1.hp.com/products/servers/proliantml570/index.html. |
| | |
|
ProLiant Essentials Foundation Pack Software |
| |||
| ||||
| ||||
| ||||
| ||||
| ||||
| ||||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials | ||||
| | ||||
| Industry Standard Compliance | ACPI 2.0 Compliant |
| PCI 2.2 Compliant | |
| PXE Support | |
| WOL Support | |
| Physical Address Extension (PAE) Support | |
| Microsoft® Logo certifications | |
|
|
|
| Availability | Advanced Memory Protection Technology delivers unsurpassed memory protection and server availability: |
|
|
|
|
| Advanced Memory Protection Configurations | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Remote Management | Integrated
Lights Out (iLO) Standard Management:
Integrated Lights
Out Advanced Pack (optional) Remote Graphical Console:
|
| | |
| Intelligent Manageability | HP Systems Insight Manager SmartStart Redundant ROM Remote Flash ROM Management Agent Integrated Management Log Automatic Server Recovery (ASR) Dynamic Sector Repairing (with Smart Array Controllers) Drive Parameter Tracking (with Smart Array Controllers) Pre-Failure Warranty (covers processors, SCSI/SAS hard drives and memory) |
|
|
|
| Security | Power-on password Hot plug keyboard password Diskette drive control Diskette boot control QuickLock, Network Server Mode Parallel and serial interface control Administrator's password Disk configuration lock Locking tower bezel door Lockable access hood |
|
|
|
| Server Power Cords | Tower Models |
|
| Rack Models |
|
|
|
|
||
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable
matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf. |
|
|
|
| Power Supply | One 910W/1300W Hot Plug Power Supply ships standard on all Tower Models and on 1P Rack Models. Second power supply is needed for redundancy. |
| Two 910W/1300W Hot Plug Power Supplies ship standard with the 2P models. | |
| | |
| System Fans | Three fans ship standard
with three additional option fans for redundancy NOTE: 2P models ship standard with redundant fans. |
|
| |
| Required Cabling | For required cabling
information, refer to the Web site at http://h18000.www1.hp.com/products/servers/ProLiantml570/. |
| | |
| OS Support | Microsoft Windows 2003 Server Microsoft Windows 2000 Server Red Hat Enterprise Linux SuSE Enterprise Linux Novell NetWare SCO OpenServer, UnixWare Sun Solaris Intel Platform Edition VMware Virtualization Software |
| NOTE:
For a more complete and up-to-date listing of supported OSs and versions,
please visit our OS Support Matrix at: http://www.hp.com/go/supportos. NOTE: For a listing of the latest drivers available for the HP ProLiant ML570 G3, please see: http://h18023.www1.hp.com/support/files/server/us/index.html. NOTE: For more Linux OS support & certification information, please visit our the ProLiant & BladeSystem Server Linux matrix http://h18004.www1.hp.com/products/servers/linux/hpLinuxcert.html NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html. NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html. |
|
|
|
|
| Rack Airflow Requirements |
Rack 10000 series Cabinets CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: http://h18000.www1.hp.com/products/servers/ProLiantml570/index.html. | |
| | |
| Rack Kit | HP ProLiant ML570 G3 rack models have universal sliding rails which provide tool-free support for square and round hole racks (including Compaq/HP 7000, 9000, 10000, HP/E series and H9 series) with an adjustment range from 23 ¾" to 36" depth. The snap-on cable management arm is now ambidextrous. |
| | |
| Telco Rack Support | Support for all 2-post Telco racks requires an additional option kit from Rack Solutions. The Rack Solutions brackets can be purchased at: http://www.racksolutions.com/hp. |
| | |
| HP Factory Express Capabilities | HP Factory
Express offers configuration, customization, integration and deployment
services for HP servers and storage products. Customers can choose how
their factory solutions are built, tested, integrated, shipped and
deployed.
Factory
Express offers service packages for simple configuration, racking,
installation, complex configuration and design services as well as
individual factory services, such as image loading, asset tagging, and
custom packaging. HP products supported through Factory Express include a
wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant
Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000,
VA7xxx, EVA, XP, rackable tape libraries and configurable network
switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
| | |
| HP Enterprise Configurator | The HP eCo-Enterprise Configurator
now provides factory default racking for our HP hardware portfolio. This
approach is aligned with our strategic direction to meet the needs and expectations
of our valued customers. If you require "custom" rack configuration,
please contact HP's Customer Business Center or an Authorized Partner for
assistance. http://www.hp.com/products/configurator. |
| | |
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of resellers and service providers. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: Server Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html HP Care Pack services include coverage for the HP branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. HP services provide continuous care and support expertise with committed response designed to meet your IT and business needs. To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime. Enhanced Care - Minimum recommended service support offer designed to ensure customers have access to expert assistance, whenever they need it.
Continuous Care - Recommended service delivering cost-effective support options designed to extend HP Services committed response and guaranteed fix times, designed to speed problem identification and resolution.
Total Care - Highest HP Support service level recommend to help increase IT performance and availability with comprehensive, integrated hardware and software services
Deployment Services - HP Installation and Start Up services designed to take time, risk, and worry out of the deployment of ProLiant servers - and free customers IT support staff to focus on what they do best, their business.
NOTE: For a complete listing of service
offerings and information visit: |
|
|
Models
| SAS Models | ||
| ML570R03 X3.00-8MB,2GB
(2P) SAS 391120-001 | Processor | (2) Intel Xeon Processors MP 3.00 GHz standard (up to four supported) |
| Cache Memory | 8MB Integrated Level 3 Cache | |
| Memory | 2048
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P600/256 BBWC
Controller NOTE: For SAS/SATA drives and integrated Dual Channel Ultra320 SCSI Adapter can be used for tape drive in removable media bay or external storage support. |
|
| Hard Drive | None ship standard | |
| Internal Storage | 2.628TB maximum (with optional hard drives) | |
| Power Supplies | Two 910W/1300W Power Supplies standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Rack (6U) | |
| | ||
| ML570T03 X3.00-8MB, 1GB (1P) SAS 391113-001 |
Processor | (1) Intel Xeon Processors MP 3.00 GHz standard (up to four supported) |
| Cache Memory | 8MB Integrated Level 3 Cache | |
| Memory | 1024 MB PC2-3200R registered
ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. |
|
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P600/256 BBWC
Controller NOTE: For SAS/SATA drives and integrated Dual Channel Ultra320 SCSI Adapter can be used for tape drive in removable media bay or external storage support. |
|
| Hard Drive | None ship standard | |
| Internal Storage | 2.628TB maximum (with optional hard drives) | |
| Power Supplies | One 910W/1300W Power Supplies standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Tower (6U) | |
|
|
||
| SCSI Models | ||
| ML570R03 X7040
2GB (2P) 399364-001 | Processor | (2) Dual-core 64-bit Intel Xeon Processors 3.00 GHz standard (up to four supported) |
| Cache Memory | 2 x 2MB Integrated Level 2 Cache | |
| Memory | 2048
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum (with optional hard drives) | |
| Power Supplies | Two 910W/1300W Power Supplies standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Rack (6U) | |
| | ||
| ML570T03
X7040 1GB (1P) 399363-001 | Processor | (1) Dual-core 64-bit Intel Xeon Processors 3.00 GHz standard (up to four supported) |
| Cache Memory | 2 x 2MB Integrated Level 2 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum (with optional hard drives) | |
| Power Supplies | One 910W/1300W Power Supplies standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Tower (6U) | |
| | ||
| ML570R03
X7020 1GB (1P) 399366-001 | Processor | (1) Dual-core 64-bit Intel Xeon Processors 2.66 GHz standard (up to four supported) |
| Cache Memory | 2 x 1MB Integrated Level 2 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum (with optional hard drives) | |
| Power Supplies | One 910W/1300W Power Supplies standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Rack (6U) | |
| | ||
| ML570T03
X7020 1GB (1P) 399365-001 | Processor | (1) Dual-core 64-bit Intel Xeon Processors 2.66 GHz standard (up to four supported) |
| Cache Memory | 2 x 1MB Integrated Level 2 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum (with optional hard drives) | |
| Power Supplies | One 910W/1300W Power Supplies standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Tower (6U) | |
| | ||
| ML570R03
X3.33-8MB, 2GB (2P) 348140-001 | Processor | (2) Intel Xeon Processors MP 3.33 GHz standard (up to four supported) |
| Cache Memory | 8MB Integrated Level 3 Cache | |
| Memory | 2048
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum (with optional hard drives) | |
| Power Supplies | Two 910W/1300W Power Supplies standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Rack (6U) | |
| | ||
| ML570R03
X3.00-8MB, 2GB (2P) 348138-001 | Processor | (2) Intel Xeon Processors MP 3.00 GHz standard (up to four supported) |
| Cache Memory | 8MB Integrated Level 3 Cache | |
| Memory | 2048
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum (with optional hard drives) | |
| Power Supplies | Two 910W/1300W Power Supplies standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Rack (6U) | |
| | ||
| ML570R03
X2.83-4MB, 1GB (1P) 348135-001 | Processor | (1) Intel Xeon Processor MP 2.83 GHz standard (up to four supported) |
| Cache Memory | 4MB Integrated Level 3 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum | |
| Power Supplies | One 910W/1300W Power Supply standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Rack (6U) | |
| | ||
| ML570R03
X3.66-1MB, 1GB (1P) 385943-001 | Processor | (1) Intel Xeon Processor MP 3.66 GHz standard (up to four supported) |
| Cache Memory | 1MB Integrated Level 2 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 464 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum | |
| Power Supplies | One 910W/1300W Power Supply standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Rack (6U) | |
| | ||
| ML570R03
X3.16-1MB, 1GB (1P) 375367-001 | Processor | (1) Intel Xeon Processor MP 3.16 GHz standard (up to four supported) |
| Cache Memory | 1MB Integrated Level 2 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum | |
| Power Supplies | One 910W/1300W Power Supply standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Rack (6U) | |
| | ||
| ML570T03
X3.33-8MB, 1GB (1P) 348139-001 | Processor | (1) Intel Xeon Processor MP 3.33 GHz standard (up to four supported) |
| Cache Memory | 8MB Integrated Level 3 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum | |
| Power Supplies | One 910W/1300W Power Supply standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Tower (6U) | |
| | ||
| ML570T03
X3.00-8MB, 1GB (1P) 348137-001 | Processor | (1) Intel Xeon Processor MP 3.00 GHz standard (up to four supported) |
| Cache Memory | 8MB Integrated Level 3 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum | |
| Power Supplies | One 910W/1300W Power Supply standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Tower (6U) | |
| | ||
| ML570T03
X2.83-4MB, 1GB (1P) 348134-001 | Processor | (1) Intel Xeon Processor MP 2.83 GHz standard (up to four supported) |
| Cache Memory | 4MB Integrated Level 3 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum | |
| Power Supplies | One 910W/1300W Power Supply standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Tower (6U) | |
| | ||
| ML570T03
X3.66-1MB, 1GB (1P) 385942-001 | Processor | (1) Intel Xeon Processor MP 3.66 GHz standard (up to four supported) |
| Cache Memory | 1MB Integrated Level 2 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum | |
| Power Supplies | One 910W/1300W Power Supply standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Tower (6U) | |
| | ||
| ML570T03
X3.16-1MB, 1GB (1P) 375366-001 | Processor | (1) Intel Xeon Processor MP 3.16 GHz standard (up to four supported) |
| Cache Memory | 1MB Integrated Level 2 Cache | |
| Memory | 1024
MB PC2-3200R registered ECC SDRAM (Standard) to 64 GB (Maximum) (2 x 1 interleaved memory and Advanced Memory Protection Technology) NOTE: Four memory boards would be required to configure up to 64 GB using 4 GB DIMMs. | |
| Network Controller | Embedded NC7782 PCI-X Gigabit Server Adapter | |
| Storage Controller | Integrated Dual Channel Ultra320 SCSI Adapter | |
| Hard Drive | None ship standard | |
| Internal Storage | 3.00TB maximum | |
| Power Supplies | One 910W/1300W Power Supply standard (second power supply for redundancy) | |
| Optical Drive | IDE Slimline DVD-ROM Drive | |
| Diskette Drive | Optional | |
| Form Factor | Tower (6U) | |
| | ||
|
|
Configuration Information - Factory Integrated Models
|
NOTE:
HP does not allow factory integration of options into standard models
listed above. |
||
| Step 1: Base Configuration (choose one of the following configurable models) | ||
| Models | HP ProLiant ML570 G3 Tower Chassis |
379933-405
|
| Factory Integrated Model ships with: | ||
| Embedded NC7782 PCI-X Gigabit Server Adapter | ||
| Ultra320 Controller (integrated on system board) | ||
| Ten Standard I/O Expansion slots | ||
| Tower models ship with one Hot Plug Power Supply and one local power cord. | ||
| Three Hot Plug Fans | ||
| Ultra320 Duplex Drive Cage (can be Simplex configured) | ||
| Integrated Lights-Out (iLO) Standard Management | ||
| Keyboard and Mouse | ||
| Tower (6U) | ||
| HP ProLiant ML570 G3 Rack Chassis |
379934-405
|
|
| Factory Integrated Model ships with: | ||
| Embedded NC7782 PCI-X Gigabit Server Adapter | ||
| Ultra320 Controller (integrated on system board) | ||
| Ten Standard I/O Expansion slots | ||
| Rack models ship with one Hot Plug Power Supply, and local power cord(s) | ||
| Three Hot Plug Fans | ||
| Ultra320 Duplex Drive Cage (can be Simplex configured) | ||
| Integrated Lights-Out (iLO) Standard Management | ||
| Rack (6U) | ||
| ML570T03 SAS Tower Chassis |
391224-405
|
|
| Factory Integrated Model ships with: | ||
| Embedded NC7782 PCI-X Gigabit Server Adapter | ||
| Ten Standard I/O Expansion slots | ||
| Tower models ship with one Hot Plug Power Supply and one local power cord | ||
| Three Hot Plug Fans | ||
| SFF SAS Drive Cage | ||
| Integrated Lights-Out (iLO) Standard Management | ||
| Keyboard and Mouse | ||
| Tower (6U) | ||
| ML570R03 SAS Rack Chassis |
391225-405
|
|
| Factory Integrated Model ships with: | ||
| Embedded NC7782 PCI-X Gigabit Server Adapter | ||
| Ten Standard I/O Expansion slots | ||
| Rack models ship with one Hot Plug Power Supply, and local power cord(s) | ||
| Three Hot Plug Fans | ||
| SFF SAS Drive Cage | ||
| Integrated Lights-Out (iLO) Standard Management | ||
| Rack (6U) | ||
|
|
||
| Step 1A: If SAS Model, Choose SAS Starter Kit or Controller (only one of the following) | ||
| SAS Controller | HP
Smart Array P600 Controller NOTE: This is a required selection if one of the two following SAS Starter Kits is not selected. If choosing this part number, SFF SAS hard drives must still be selected under Step 4. | 337972-B21 |
| SAS Starter Kit | SAS
Starter Kit - 36GB NOTE: Includes HP Smart Array P600/256 BBWC Controller and (2) 36GB SFF SAS Universal Hard Drives. |
396221-B21 |
| SAS Starter
Kit - 72GB NOTE: Includes HP Smart Array P600/256 BBWC Controller and (2) 72GB SFF SAS Universal Hard Drives. |
396220-B21 | |
| | ||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | X3.00-2x2MB 570 G3 FIO |
399889-L21
|
| X2.66-2x1MB 570 G3 FIO |
399888-L21
|
|
| X3.33-8MB 570 G3 FIO |
348111-L21
|
|
| X3.00-8MB 570 G3 FIO |
348110-L21
|
|
| X2.83-4MB 570 G3 FIO |
348109-L21
|
|
| X3.66-1MB 570 G3 FIO |
385903-L21
|
|
| X3.16-1MB 570 G3 FIO |
375369-L21
|
|
| NOTE: Up to 3 additional xxxxxx-B21 processors for each HP ProLiant ML570 server may be ordered. If selecting a Performance Pack option (404476-001, 380927-001 or 380928-001), a second processor (399889-B21, 348111-B21 or 348110-B21) is included and should not be ordered. | ||
| Base Memory |
8 GB (2 x 4 GB 2RANK) PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities |
348106-B21
|
| 4 GB (2 x 2 GB 2RANK) PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities |
375004-B21
|
|
| 4 GB (2 x 2 GB 1RANK) PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities |
343057-B21
|
|
| 2 GB (2 x 1 GB 1RANK) PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities |
343056-B21
|
|
| 1 GB (2 x 512 MB 1RANK) PC2-3200R 400MHz DDR2 with Advanced ECC and online spare memory capabilities |
343055-B21
|
|
| Optical Drive |
Slimline CD-RW/DVD-ROM 24X Combo Drive Option Kit (Servers) |
331903-B21
|
| Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers) |
264007-B21
|
|
|
|
||
| Step 3: Choose Additional Factory Integratable Options | ||
|
The HP ProLiant ML570 G3 performance packs are necessary to configure
a HP ProLiant ML570 G3 High Performance Model. HP ProLiant ML570 G3 High
Performance models include the latest performance technologies and enterprise
class availability features pre-installed for convenience and value. In
addition to the standard features listed in Step 1, the High Performance
Model includes the following:
|
||
| ML570G3 X7040 Rack Optimized Pack |
404476-001
|
|
| ML570G3 X3.33GHz/667-8MB Rack Optimized Pack |
390927-001
|
|
| ML570G3 X3.00GHz/667-8MB Rack Optimized Pack |
390928-001
|
|
|
|
||
| Step 4: Choose Additional Options for Factory Integration |
| NOTE: For additional options, please refer to the "Options" section below. |
|
|
Options
| NOTE: Some options may not be factory configurable. Please contact your local sales representative for additional information. | ||
| HP ProLiant ML570 G3 Unique Options | ProLiant Tower to Rack Conversion Kit |
348112-B21
|
| ProLiant Rack to Tower Conversion Kit |
348113-B21
|
|
|
|
||
| Processor | Dual-Core Intel Xeon
7040 (3.00GHz-2x2MB) Processor Option Kit NOTE: This processor option kit (PN 399889-B21) supports the HP ProLiant ML570 G3 and the HP ProLiant DL580 G3. |
399889-B21 |
| Dual-Core Intel Xeon
7020 (2.66GHz-2x1MB) Processor Option Kit NOTE: This processor option kit (PN 399888-B21) supports the HP ProLiant ML570 G3 and the HP ProLiant DL580 G3. |
399888-B21 | |
| Intel Xeon MP X3.33
GHz-8MB Processor Option Kit NOTE: This processor option kit (PN 348111-B21) supports the HP ProLiant ML570 G3 and the HP ProLiant DL580 G3. |
348111-B21 | |
| Intel Xeon MP X3.00
GHz-8MB Processor Option Kit NOTE: This processor option kit (PN 348110-B21) supports the HP ProLiant ML570 G3 and the HP ProLiant DL580 G3. |
348110-B21
|
|
| Intel Xeon MP X2.83
GHz-4MB Processor Option Kit NOTE: This processor option kit (PN 348109-B21) supports the HP ProLiant ML570 G3 and the HP ProLiant DL580 G3. |
348109-B21
|
|
| Intel
Xeon MP X3.66 GHz-1MB Processor Option Kit NOTE: This processor option kit (PN 385903-B21) supports the HP ProLiant ML570 G3 and the HP ProLiant DL580 G3. |
385903-B21
|
|
| Intel
Xeon MP X3.16 GHz-1MB Processor Option Kit NOTE: This processor option kit (PN 375369-B21) supports the HP ProLiant ML570 G3 and the HP ProLiant DL580 G3. |
375369-B21
|
|
| NOTE: Processor mixing of different frequencies and cache sizes is not supported. | ||
|
|
||
| ProLiant
Essentials Value Pack Software |
ProLiant Essentials Intelligent Networking Pack | |
| ProLiant Essentials
Intelligent Networking Pack - Windows Edition, Single Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
436225-B21 |
|
| NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_na/12062_na.html | ||
| ProLiant Essentials Intelligent Networking Pack - Linux Edition, Single Server License |
436229-B21
|
|
| NOTE:
For additional ProLiant Intelligent Networking Pack - Linux License
Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_na/12327_na.html |
||
| ProLiant Essentials Performance Management Pack | ||
| ProLiant Essentials
Performance Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation. NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp. |
306696-B21 |
|
| NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_na/11925_na.html | ||
| ProLiant Essentials Rapid Deployment Pack Windows Edition Release | ||
| Rapid Deployment
Pack, Single-Server License NOTE: This license allows 1 server to be deployed and managed via RDP. |
267196-B21 |
|
| ProLiant Essentials Rapid Deployment Pack - Physical Media Kit |
434559-B21
|
|
| ProLiant Essentials Rapid Deployment Pack Flatpack - single-server license |
434560-B21
|
|
| NOTE:
For additional ProLiant Essentials Rapid Deployment Pack License Kits please
see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html |
||
| ProLiant Essentials Workload Management Pack | ||
| ProLiant Essentials Workload Management Pack, Single Server License |
303284-B21
|
|
| NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_na/11452_na.html | ||
| ProLiant Essentials Virtualization Management Software | ||
| ProLiant Essentials
Virtual Machine Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
435661-B21 |
|
| ProLiant Essentials
Server Migration Pack, Single-Migration License NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation. NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. |
435663-B21
|
|
| ProLiant Essentials
Server Migration Pack - Physical to ProLiant Edition, Single-Migration License |
412978-B21
|
|
| HP ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. 1 Year Unlimited Migration License |
412982-B21
|
|
| NOTE: For additional ProLiant Essentials Virtualization Management Software License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.html | ||
| ProLiant Essentials Vulnerability and Patch Management Pack | ||
| ProLiant Essentials
Vulnerability and Patch Management Pack, Single-Server License NOTE: For use with a single server. Contains one license with a unique license activation key and documentation. |
371645-B21
|
|
| NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_na/12111_na.html | ||
| NOTE:
Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials
or the various ProLiant Essentials Value Pack product QuickSpecs for more
information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials. |
||
|
|
||
| Remote Management | Integrated Lights-Out Advanced Pack | |
| Integrated Lights-Out
Advanced Pack, 1 server Featuring: Sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites. |
263825-B21 |
|
| NOTE:
For additional Integrated Light-Out Advanced Pack License Kits please
see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12326_div/12326_div.html |
||
|
|
||
|
Memory (DIMMs) |
8 GB PC2-3200R Registered ECC SDRAM Memory Kit (2 x 4096 MB) Dual Rank |
348106-B21
|
| 4 GB PC2-3200R Registered ECC SDRAM Memory Kit (2 x 2048 MB) Dual Rank |
375004-B21
|
|
| 4 GB PC2-3200R Registered ECC SDRAM Memory Kit (2 x 2048 MB) Single Rank |
343057-B21
|
|
| 2 GB PC2-3200R Registered ECC
SDRAM Memory Kit (2 x 1024 MB) |
343056-B21
|
|
| 1 GB PC2-3200R Registered ECC SDRAM Memory Kit (2 x 512 MB) |
343055-B21
|
|
| Hot-plug Memory Expansion Board |
348107-B21
|
|
| NOTE: Four memory boards would be required to configure 48 GB of memory using 2 GB DIMMs. | ||
|
|
||
| Optical Drives | Slimline DVD-ROM Drive (8X/24X)
Option Kit (Servers) NOTE: This drive is supported in the removable media bay. |
264007-B21
|
| Slimline CD-RW/DVD-ROM Combo Drive
Option Kit NOTE: This drive is supported in the DVD-ROM bay and floppy bay |
331903-B21
|
|
| HP DVD+R/RW 8X Slim |
383975-B21
|
|
| Slimline CD-ROM Drive 24X |
356963-B21
|
|
|
|
||
| Diskette Drive | Slimline Floppy Diskette Drive Option Kit |
390164-B21
|
|
|
||
| SAS Drive Cage | ML570G3 SAS Drive Cage Option Kit |
378101-B21
|
|
|
||
| Hard Drives | Ultra320 SCSI – Universal Hot Plug | |
| HP 300GB U320 10K Universal HDD |
350964-B22
|
|
| HP 146GB U320 10K Universal HDD |
286716-B22
|
|
| HP 72GB U320 10K Universal HDD |
286714-B22
|
|
| HP 300GB U320 15K Universal HDD |
411089-B22
|
|
| HP 146GB U320 15K Universal HDD |
347708-B22
|
|
| HP 72GB U320 15K Universal HDD |
286778-B22
|
|
| HP 36GB U320 15K Universal HDD |
286776-B22
|
|
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. | ||
| NOTE: Please see
the Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature: http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html |
||
| Serial Attached SCSI (SAS) SFF Hot Plug | ||
| HP 146GB 3G SAS 10K SFF SP HDD |
431958-B21
|
|
| HP 72GB 3G SAS 10K SFF SP HDD
|
375861-B21
|
|
| HP 72GB 3G SAS 15K SFF SP HDD |
431935-B21
|
|
| HP 36GB 3G SAS 10K SFF SP HDD |
375859-B21
|
|
| HP 36GB 3G SAS 15K SFF SP HDD |
431933-B21
|
|
| NOTE: Please see
the SAS Hard Drive QuickSpecs for Technical Specifications such as capacity,
height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature: http://h18000.www1.hp.com/products/quickspecs/12244_na12244_na.html |
||
| SATA Hot Plug |
||
| HP 120GB 1.5G SATA 5.4K SFF HDD |
431786-B21
|
|
| HP 60GB 1.5G SATA 5.4K SFF HDD |
379306-B21
|
|
| NOTE: SATA drives
have a 1-year warranty. Please see the SATA Hard Drive QuickSpecs for Technical
Specifications such as capacity, height, width, interface, transfer rate,
seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/11940_na/11940_na.html |
||
|
|
||
| Storage Controllers | SAS Controllers | |
| Smart Array P600 Controller | ||
| HP Smart Array P600/256 BBWC Controller NOTE: Included in SAS Server Models. Only needed with SAS Drive Cage Option Kit. |
337972-B21
|
|
| 512MB DDR BBWC Upgrade |
372538-B21
|
|
| NOTE: Please see
the following Controller QuickSpecs for additional information including
Technical Specifications: http://h18000.www1.hp.com/products/quickspecs/12247_na/12247_na.html (Smart Array P600 Controller) |
||
| SAS HBA |
||
| HP SC44Ge Host Bus Adapter |
416096-B21
|
|
| HP 8 Internal Port SAS HBA with RAID |
347786-B21
|
|
| NOTE:
Please see the HBA QuickSpecs for additional information: http://h18004.www1.hp.com/products/quickspecs/12617_na/12617_na.html (SC44Ge HBA) http://h18004.www1.hp.com/products/quickspecs/12332_na/12332_na.html (8 Internal Port SAS HBA) |
||
| SCSI Controllers | ||
| Smart Array 6402/128 Controller |
273915-B21
|
|
| Smart Array 6404/256 Controller | 273914-B21 | |
|
Smart Array 641 Controller |
291966-B21
|
|
|
Smart Array 642 Controller |
291967-B21
|
|
| 128-MB BBWC (Battery-Backed Write
Cache) Enabler NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller. |
351580-B21
|
|
| Ultra320 Expansion Module for SA-6402 | 273911-B21 | |
| 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
|
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/11587_na/11587_na.html (Smart Array 6400 Series) http://h18000.www1.hp.com/products/quickspecs/12067_na/12067_na.html (Smart Array 641) http://h18000.www1.hp.com/products/quickspecs/12069_na/12069_na.html (Smart Array 642) http://h18000.www1.hp.com/products/quickspecs/11943_na/11943_na.html (Single Channel U320 SCSI G2 HBA) |
||
|
|
||
| Communications | HP NC110T PCI Express Gigabit
Server Adapter |
434905-B21
|
| HP NC310F PCI-X 1000SX Gigabit Server Adapter |
368169-B21
|
|
| HP NC340T PCI-X 4-port 1000T Gigabit Server Adapter |
391661-B21
|
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC510F PCIe 10 Gigabit Server
Adapter NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510F adapter. |
414126-B21
|
|
| HP NC510C PCIe 10 Gigabit Server
Adapter NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510C adapter. |
414129-B21
|
|
| HP NC7771 PCI-X 1000T Gigabit Server Adapter |
290563-B21
|
|
|
|
||
|
Redundant Options | Hot-plug
Redundant Fan Kit NOTE: Includes three fans. Included in 2P models. |
348108-B21 |
| 910W (low line), 1300W (high line) Hot Plug Redundant Power Supply |
348114-001 | |
| 910W
(low line), 1300W (high line) Hot Plug Redundant Power Supply NOTE: Includes C14 to C19 IEC cable. |
348114-B21 | |
|
| ||
|
Management Options |
Remote Insight Lights-Out Edition II |
227251-001 |
|
|
||
|
Tape Drives |
| ||||||||||||||||||||||||||||||||||||||
| | |||||||||||||||||||||||||||||||||||||||
| Tape Autoloaders | HP StorageWorks DAT Autoloader | |
| HP StorageWorks DAT 72x10 tape autoloader | AE313A | |
| HP StorageWorks Tape 1/8 Autoloader | ||
| HP StorageWorks 1/8 Ultrium 920 G2 Tape Autoloader | AH165A | |
| HP StorageWorks 1/8 Ultrium 448 G2 Tape Autoloader | AH164A | |
| HP StorageWorks 1/8 Ultrium 232 G2 Tape Autoloader | AH163A | |
| HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions |
AH166A | |
| NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs | ||
|
|
||
| Tape Libraries | HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 Ultrium 960 Drive Library | AG115A | |
| HP StorageWorks MSL2024 1 Ultrium 960 4GB FC Drive Library | AG326B | |
| HP StorageWorks MSL2024 1 Ultrium 920 Drive Library | AH169A | |
| HP StorageWorks MSL2024 2 Ultrium 920 Drive Library | AH170A | |
| HP StorageWorks MSL2024 1 Ultrium 448 Drive Library | AG116A | |
| HP StorageWorks MSL2024 2 Ultrium 448 Drive Library | AG117A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 1 Ultrium 448 Drive Library |
AG320A
|
|
| HP StorageWorks MSL4048 2 Ultrium 448 Drive Library |
AG321A
|
|
| HP StorageWorks MSL4048 1 Ultrium 920 Drive Library | AH171A | |
| HP StorageWorks MSL4048 2 Ultrium 920 Drive Library | AH172A | |
| HP StorageWorks MSL4048 1 Ultrium 960 Drive Library |
AG322A
|
|
| HP StorageWorks MSL4048 1 Ultrium 960 4GB FC Drive Library | AG324B | |
| HP StorageWorks MSL4048 2 Ultrium 960 Drive Library |
AG323A
|
|
| HP StorageWorks MSL4048 2 Ultrium 960 4GB FC Drive Library | AG325B | |
| HP StorageWorks MSL6000 Tape Library | ||
| Ultrium 960 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library | AD606B | |
| HP StorageWorks MSL6030 1 Ultrium 960 Dr FC Library | AD608B | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library | AD607B | |
| HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library | AD609B | |
| Ultrium 460 technology | ||
| HP StorageWorks MSL6030 1 Ultrium 460 Dr LVDS Library | AD598B | |
| HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library | AD600B | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library | AD599B | |
| HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library | AD601B | |
| NOTE: Please reference the MSL2024, MSL4048, and MSL6000 Tape Library QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs. | ||
|
|
||
| HP Data Protector Express Software | HP DP Express Backup Server Upgrade for ProLiant Software | BB117AP |
| HP DP Express Package for Microsoft Small Business Server | BB118AA | |
| NOTE:
Please see the HP Data Protector Express QuickSpecs for additional information
regarding the purchase of HP Data Protector Express software: http://h18000.www1.hp.com/products/quickspecs/12337_na/12337_na.html NOTE: To obtain a free licensed copy of HP Data Protector Express for ProLiant edition software, please visit the "Protect Your Data" link accessible from your ProLiant server's System Management Homepage (SMH) software (SmartStart 7.5 or later). | ||
| | ||
| Cluster Options | ProLiant Cluster Starter Kit | 364023-B22 | ||
| NOTE: For additional
information regarding the ProLiant Cluster Starter Kit please see the following
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html |
||||
| HP HA/F200 for Entry SAN Cluster | 364026-B22 | |||
| NOTE: For additional
information regarding the ProLiant Cluster for Entry Level SAN please see
the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html |
||||
| ProLiant Cluster HA/F500 for the Enterprise SAN | 364024-B21 | |||
| NOTE: For additional
information regarding the ProLiant Cluster HA/F500 for Enterprise SAN please
see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11933_na/11933_na.html |
||||
| HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 (2 node license cluster kit) | 305199-B26 | |||
| HP Serviceguard for Linux A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 (single license version) | 307754-B26 |
|||
| HP Serviceguard for Linux and Red Hat Global File System - 1 year subscription | T2798AA#001 | |||
| HP Serviceguard for Linux and Red Hat Global File System - 3 years subscription | T2798AA#003 | |||
| NOTE: For additional
information regarding the HP Serviceguard for Linux License, please see
the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html NOTE: For configuration/certification options for the HP Parallel Database Cluster for Oracle RAC please go to: http://www.hp.com/solutions/highavailability/oracle |
||||
|
|
||||
| HP StorageWorks Modular Smart Array 20 | HP
StorageWorks Modular Smart Array 20 NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. | 335921-B21 |
| HP StorageWorks Modular Smart
Array 20 Starter Kit NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller. | 366172-B21 | |
| NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 3.5" Hot Plug Hard Drives. | ||
| | ||
| HP StorageWorks Modular Smart Array 30 | HP
StorageWorks Modular Smart Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies | 302969-B21 |
| HP StorageWorks Modular Smart
Array 30 DB NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies | 302970-B21 | |
| NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3, Ultra320 Hot Plug Hard Drives. | ||
| | ||
| HP StorageWorks Modular Smart Array 50 | HP StorageWorks Modular Smart Array 50 Enclosure |
364430-B21 |
| NOTE:
Please see the Modular Smart Array 50 QuickSpecs for additional options and configuration
information at: http://h18000.www1.hp.com/products/quickspecs/12245_na/12245_na.html | ||
| | ||
| HP StorageWorks Modular Smart Array 1000 | HP StorageWorks Modular Smart Array 1000 |
201723-B22 |
| NOTE:
Please see the Modular Smart Array 1000 QuickSpecs for additional options
and configuration information at: http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.html | ||
| | ||
| HP StorageWorks Modular Smart Array 1500 | Modular Smart Array 1500 Controller Shelf |
AA986A
|
| NOTE: Please see
the StorageWorks Modular SAN Array 1500 QuickSpecs for additional options
and configuration information at: http://www.hp.com/go/MSA1500cs |
||
|
|
||
| StorageWorks Options |
NOTE: The following
is a list of all Fibre Channel Host Bus Adapters for Windows and Linux.
For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html |
|
| HP StorageWorks FC2142SR 4Gb PCI-e HBA |
A8002A
|
|
| HP StorageWorks FC2242SR Dual Channel 4 Gb PCI-e HBA |
A8003A
|
|
| HP StorageWorks FC1142SR 4Gb PCI-e HBA |
AE311A
|
|
| HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-e HBA |
AE312A
|
|
| HP StorageWorks FC2143 4Gb PCI-X 2.0 -to-Fibre Channel HBA |
AD167A
|
|
| HP StorageWorks FC2243 Dual Channel 4Gb PCI-X 2.0 HBA |
AD168A
|
|
| HP StorageWorks FC1143 4Gb PCI-X 2.0 HBA |
AB429A
|
|
| HP StorageWorks FC1243 Dual Channel 4Gb PCI-X 2.0 HBA |
AE369A
|
|
|
|
||
|
HP Uninterruptible Power Systems - Tower |
HP, T1000 UPS |
AF403A
|
| HP, T1500 UPS |
AF406A
|
|
| HP, R/T 2200 UPS |
AF409A
|
|
|
|
||
|
Uninterruptible Power Systems – Rack |
HP, R1.5kVA UPS, 1U |
AF419A
|
| HP R3000 VA UPS, 2U, L5-30 NOTE: Replaces non-RoHS compliant part number 192186-001. |
AF422A | |
| HP R3000 VA UPS, 2U, L6-20 NOTE: Replaces non-RoHS compliant part number 192186-002. |
AF423A | |
|
|
||
| HP Monitored Power Distribution Unit (PDU) | HP Monitored Power Distribution
Unit: Full Rack Version |
|
| HP 17.3 kVA S2324 Monitored PDU-
dual input, 3U, 24A NOTE: Replaces non-RoHS compliant part number 370959-D71. |
AF503A
|
|
| HP 8.3 kVA S1324 Monitored PDU-
single input, 3U, 24A NOTE: Replaces non-RoHS compliant part number 370960-D71. |
AF504A
|
|
| HP 16.6 kVA S2140 Monitored PDU-
dual input, 1U, 40A NOTE: Replaces non-RoHS compliant part number 37061-D71. |
AF505A
|
|
| HP 8.6 S1140 Monitored PDU- single
input, 1U, 40A NOTE: Replaces non-RoHS compliant part number 370962-D71. |
AF506A
|
|
| HP Monitored Power Distribution Unit: Half Rack Version | ||
| HP 17.3 kVA S348 Monitored PDU- single input, 3-phase, 60A |
AF916A
|
|
| HP 4.9kVA S124 Monitored PDU- single input, 1U, 24A |
AF914A
|
|
|
|
||
|
Modular PDUs 1U/0U |
3.6kVA Model - mPDU, 16A, High |
252663-B24 |
| 2.8 kVA Model - mPDU, 24A, Low |
252663-D71 |
|
| 4.9kVA Model - mPDU, 24A, High |
252663-D72 |
|
| 8.3kVA Model - mPDU, 40A, High |
252663-B21 |
|
| 8.3kVA Model - mPDU, 40A, High
(power cord attached) |
252663-D73
|
|
| 8.3kVA Model - mPDU 40A, High
(core only) |
252663-D75
|
|
| 4.9kVA Model - mPDU 24A, High (core only |
252663-D74
|
|
| NOTE: Please see
the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs) QuickSpecs
for additional options including shorter jumper cables: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html |
||
|
|
||
| USB Options | USB 2-Button Optical Scroll Mouse (Carbonite/Silver) | DC172B |
| HP USB 04 Standard Keyboard | DT528A#xxx | |
| USB 2.0 4-port HUB | DG954A | |
| HP 1GB Drive Key II- USB 2.0 Flash Drive | AG382AA | |
| HP 512MB DriveKey II- USB Flash Drive | ED516AA | |
|
|
||
|
Rack Conversion Kit |
ProLiant Tower to Rack Conversion
Kit |
348112-B21
|
| ProLiant Rack to Tower Conversion Kit |
348113-B21
|
|
|
|
||
| HP Rack 5000 Series (Graphite Metallic) | HP
5642 Rack-Unassembled NOTE: Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_na/12074_na.html NOTE: For additional information regarding Rack Cabinets, please see the following URL: www.hp.com/go/rackandpower. |
358254-B21 |
|
| ||
| HP Rack 10000 G2
Series (Carbon/Graphite Metallic) |
10642 G2 (42U) Rack Cabinet - Pallet |
AF001A
|
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A
|
|
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A
|
|
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet |
AF004A
|
|
| 10636 G2 (36U) Rack Cabinet - Pallet |
AF011A
|
|
| 10636 G2 (36U) Rack Cabinet - Shock Pallet |
AF012A
|
|
| 10636 G2 (36U) Rack Cabinet - Crated |
AF013A
|
|
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet |
AF014A
|
|
| 10622 G2 (22U) Rack Cabinet -
Pallet |
AF021A
|
|
| 10622 G2 (22U) Rack Cabinet -
Shock Pallet |
AF022A
|
|
| 10842 G2 (42U) 800mm Wide Rack
Cabinet - Pallet |
AF041A
|
|
| 10842 G2 (42U) 800mm Wide Rack
Cabinet - Shock Pallet |
AF042A
|
|
| 10647 G2 (47U) Rack Cabinet - Pallet |
AF031A
|
|
| NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. | ||
| NOTE: Please see
the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
|
HP Rack 10000 Series |
10642 (42U) Infrastructure Rack (Low Voltage) |
379006-001
|
| 10642 (42U) Infrastructure Rack (High Voltage) |
379005-001
|
|
| HP Rack S10614 (14U) Rack Cabinet Shock Pallet |
292302-B22
|
|
|
HP Rack 10842 (42U, 800mm wide) – Pallet |
257415-B21 |
|
|
HP Rack 10842 (42U, 800mm wide) – Shock Pallet |
257415-B22 |
|
|
HP Rack 10647 (47U) – Pallet |
245160-B21 |
|
|
HP Rack 10647 (47U) – Crated |
245160-B23 |
|
|
HP Rack 10622 (22U) – Pallet |
245163-B21 |
|
|
HP Rack 10622 (22U) – Shock Pallet |
245163-B22 |
|
|
HP Rack 10622 (22U) – Crated |
245163-B23 |
|
|
NOTE: xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). xxxxxx-B23 (crated) used for air shipments of empty racks. |
|
|
|
NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. Not all HP equipment is qualified to be shipped in the Rack 10000 series |
|
|
|
NOTE: Please see the Rack 10000 QuickSpecs
for Technical Specifications such as height, width, depth, weight, and
color: |
|
|
|
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
|
|
|
|
||
|
Keyboards and Monitors |
TFT7210R Rack Mounted 17" Monitor | 348373-B21 |
| TFT7600 Rackmount Keyboard Monitor | AG052A | |
| 1U Rackmount Keyboard with USB | AG072A | |
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
| HP KVM Switch Options | 2x1x16 IP Console Switch with Virtual Media |
AF601A
|
| 4x1x16 IP Console Switch with Virtual Media |
AF602A
|
|
| 2x16 Server Console Switch with Virtual Media |
AF600A
|
|
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A
|
|
| Server Console Switch (KVM), 0 x 1 x 8 port |
336044-B21
|
|
| Server Console Switch (KVM), 0 x 2 x 16 port |
336045-B21
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| USB Interface Adapter, 1 pack |
336047-B21
|
|
| Serial Interface adapter - 1 Pack with power supply |
373035-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x 4 Console Switch |
AF611A
|
|
| PS2 Server Console Cable, 6 ft, 2 pack |
AF612A
|
|
| USB Server Console Cable, 6 ft, 2 pack |
AF613A
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| HP Serial Console Server Options | HP 16 Port Serial Console Server | AF101A |
| HP 48 Port Serial Console Server | AF102A | |
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack | AF103A | |
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack | AF110A | |
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
| | ||
| Service and Support Offerings (HP Care Pack Services) |
|
||||||||
|
|||||||||
|
|||||||||
|
|||||||||
|
|
|
Memory
|
HP ProLiant ML570 G3 - 7040,
3.33 GHz and 3.00 GHz 1P Tower Models and all 7020, 2.83 GHz, 3.66 GHz,
3.16 GHz Models Standard Memory Standard Memory Plus Optional Memory Standard Memory Replaced with Optional Memory
NOTE: This
chart does not represent all possible memory configurations. |
|
Memory
|
Slot
|
||||||
|
|
1 |
2
|
3
|
4
|
5
|
6
|
|
|
Standard |
1 GB
|
512 MB
|
512 MB
|
Empty
|
Empty
|
Empty
|
Empty
|
|
Optional |
57 GB
|
512 MB
|
512 MB
|
4 GB
|
4 GB
|
Empty
|
Empty
|
|
Maximum
|
64 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
Empty
|
Empty
|
|
Memory
|
Slot
|
||||||
|
|
7
|
8
|
9
|
10
|
11
|
12
|
|
|
Standard |
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
|
Optional |
57 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
Empty
|
Empty
|
|
Maximum
|
64 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
Empty
|
Empty
|
|
Memory
|
Slot
|
||||||
|
|
13 |
14
|
15
|
16
|
17
|
18
|
|
|
Standard |
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
|
Optional |
57 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
Empty
|
Empty
|
|
Maximum
|
64 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
Empty
|
Empty
|
|
Memory
|
Slot
|
||||||
|
|
19
|
20
|
21
|
22
|
23
|
24
|
|
|
Standard |
1 GB
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
Empty
|
|
Optional |
57 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
Empty
|
Empty
|
|
Maximum
|
64 GB
|
4 GB
|
4 GB
|
4 GB
|
4 GB
|
Empty
|
Empty
|
|
Following are memory options available from HP: |
|
|
348106-B21 |
|
375004-B21 |
|
343057-B21 |
|
343056-B21 |
|
343055-B21 |
|
348107-B21 |
|
HP ProLiant ML570 G3 - 7040,
3.33 GHz and 3.00 GHz 2P Rack Models Standard Memory Standard Memory Plus Optional
Memory Standard Memory Replaced with Optional Memory NOTE: This chart
does not represent all possible memory configurations. |
|
Memory |
Slot | ||||||
|
| 1 | 2 |
3 | 4 |
5 | 6 | |
| Standard |
2 GB | 512
MB | 512 MB |
512 MB | 512
MB | Empty |
Empty |
|
Optional | 58
GB | 512 MB |
512 MB | 512
MB | 512 MB |
4 GB |
4 GB |
|
Maximum |
64 GB | 4
GB | 4 GB |
4 GB | 4
GB | Empty |
Empty |
|
Memory |
Slot | ||||||
|
|
7 | 8 |
9 | 10 |
11 | 12 | |
| Standard |
2 GB | Empty |
Empty | Empty |
Empty | Empty |
Empty |
|
Optional | 58
GB | 4 GB |
4 GB | 4
GB | 4 GB |
Empty | Empty |
| Maximum |
64 GB | 4
GB | 4 GB |
4 GB | 4
GB | Empty |
Empty |
| Memory |
Slot | ||||||
|
| 13 | 14 |
15 | 16 |
17 | 18 | |
| Standard |
2 GB | Empty |
Empty | Empty |
Empty | Empty |
Empty |
|
Optional | 58
GB | 4
GB | 4
GB | 4
GB | 4
GB | Empty |
Empty |
|
Maximum |
64 GB | 4
GB | 4 GB |
4 GB | 4
GB | Empty |
Empty |
|
Memory |
Slot | ||||||
|
|
19 | 20 |
21 | 22 |
23 | 24 | |
| Standard |
2 GB | Empty |
Empty | Empty |
Empty | Empty |
Empty |
|
Optional | 58
GB | 4 GB |
4 GB | 4
GB | 4 GB |
Empty | Empty |
| Maximum |
64 GB | 4
GB | 4 GB |
4 GB | 4
GB | Empty |
Empty |
|
Following are memory options available from HP: |
|
|
348106-B21 |
|
375004-B21 |
|
343057-B21 |
|
343056-B21 |
|
343055-B21 |
|
348107-B21 |
|
|
Storage
|
1-inch Drive Locations | |
|
0-7, 0-1 | Ten Ultra320 SCSI Drive Bays (8 on one channel, 2 on another) | |
|
A | 1.44-MB Slimline Diskette Drive (optional) | |
|
B | 8x/24x IDE Slimline DVD-ROM | |
|
C | One available removable media bay for storage. A half-height tape drive or a USB tape drive may be installed in the removable media bay. | |
|
SFF SAS Drive Locations | |
|
1-18 | Eighteen SFF SAS Drive Bays | |
|
A | 1.44-MB Slimline Diskette Drive (optional) | |
|
B | 8x/24x IDE Slimline DVD-ROM | |
|
C | One available removable media bay for storage. A half-height tape drive or a USB tape drive may be installed in the removable media bay. | |
| Drive Support |
|
|
|
Hard Drives | ||||
| Ultra320 Hot Pluggable Drives | ||||
| Quantity |
Position |
| ||
|
300GB U320 10K | Up to 10 | 0-7 and 0-1 | Integrated Dual Channel
Ultra320 SCSI Adapter | |
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320 transfer rates. | ||||
|
| ||||
| SFF SATA Hot Pluggable Drives | ||||
|
Quantity |
Position |
| ||
|
120GB 1.5G SATA 5.4K | Up to 18 | 1-18 |
HP Smart Array P600/256 BBWC Controller | |
|
| ||||
| SFF SAS Hot Pluggable Drives | ||||
|
Quantity |
Position |
| ||
|
146GB 3G SAS 10K SP | Up to 18 | 1-18 |
HP Smart Array P600/256 BBWC Controller | |
| NOTE: SAS Drives supported by the HP ProLiant ML570 G3 SAS Models only or with HP ProLiant ML570 G3 model upgraded SAS Drive Cage Option Kit. | ||||
|
| ||||
|
External Storage |
||||
|
Quantity |
Position |
|
||
|
Modular Smart Array 30 Family |
Up to 28 |
External |
Smart Array 6402/128 Controller Smart Array 6404/256 Controller Smart Array 642 Controller |
|
| Modular Smart Array 50 Enclosure | Up to 2 | External | HP Smart Array P600/256 BBWC Controller | |
| Modular Smart Array 1000 | Please see the Modular Smart Array 1000 QuickSpecs below to determine configuration requirements | External | Please see the Modular Smart Array
1000 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/MSA1000 |
|
| Modular Smart Array 1500 cs | Please see the Modular Smart Array 1500 cs QuickSpecs below to determine configuration requirements | External | Please see the Modular Smart Array
1500 cs QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/MSA1500cs |
|
|
|
||||
|
Maximum Storage Capacity (ML570 10 Bay Hot Plug Ultra320 SCSI Drive Cage, 4 channel controller in 4 full-length PCI-X slots & MSA30 enclosures) | |
| Internal | 3.00TB ((10 x 300GB) Ultra320 SCSI Drives) |
| External | 67.20TB hot plug SCSI storage (16 x (14 x 300GB Ultra320 SCSI Drives)) |
| Total | 70.20TB |
| | |
| Maximum Storage Capacity SAS Models (ML570 SFF SAS Drive Cage, 8 port SAS controller in 4 slots & MSA50 enclosures) | |
|
Internal |
2.628TB ((18 x 146GB) SFF SAS Drives) |
| External | 11.680TB hot plug SFF SAS storage (4 x (20 x 146GB SFF SAS Drives)) |
| Total | 14.308TB |
| | |
| Tape Drives, Tape Autoloaders, & Tape Libraries | |||
|
NOTE: For an up-to-date listing of
the latest O/S Support details for each of the Tape Drives listed below,
please see the following: |
|||
|
Position |
Controller |
Controller Part Number |
|
| HP StorageWorks Tape Drives,
Internal DAT 24 USB DAT 40 USB DAT 72 USB |
B or C
|
USB 2.0 Port |
N/A
|
| HP StorageWorks Tape Drives,
External DAT 24 USB DAT 40 USB DAT 72 USB |
External
|
USB 2.0 Port |
N/A
|
| HP StorageWorks Tape Drives,
Internal Ultrium 232 Ultrium 448 Ultrium 920 DAT 40 DAT 72 DLT VS160 |
B or C
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
| HP StorageWorks Tape Drives,
Internal Ultrium 460 Ultrium 960 SDLT 600 |
B or C
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
| HP StorageWorks Tape Drives,
External Ultrium 232 Ultrium 448 Ultrium 460 Ultrium 920 Ultrium 960 DAT 40 DAT 72 DLT VS160 SDLT 600 |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
| HP StorageWorks Autoloaders,
External DAT 72x10 Autoloader 1/8 G2 Tape Autoloader |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
| HP StorageWorks SCSI Rack-Mount
Tape Drive Enclosures 1U Rack-Mount Kit 3U Rack-Mount Kit |
External
|
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 |
374654-B21
|
| HP StorageWorks USB Rack-Mount
Tape Drive Enclosures 1U Rack-Mount Kit |
External
|
USB 2.0 Port |
N/A
|
| HP StorageWorks Tape Libraries,
External MSL2024 (Ultrium 448, Ultrium 920 and 960-based) MSL4048 (Ultrium 448, Ultrium 920 and 960-based) MSL6000 (Ultrium 960 and 460-based) MSL6000 (SDLT 600-based) |
External
|
Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs for detailed connectivity information. |
N/A
|
|
|
Power Specifications
|
Part Number | 337867-001 | |
| Spare Kit | 364360-001 | |
| Operational Input Voltage Range (Vrms) | 90 to 264 | |
| Frequency Range (Nominal) (Hz) | 47 to 63 (50/60) | |
|
| ||
| Nominal Input Voltage (Vrms) |
100
|
115
|
208
|
220
|
230
|
240
|
| Max Rated Output Wattage Rating |
910
|
910
|
1300
|
1300
|
1300
|
1300
|
| Nominal Input Current (A rms) |
11.9
|
10.2
|
7.7
|
7.3
|
6.9
|
6.6
|
| Max Rated Input Wattage Rating (Watts) |
1163
|
1148
|
1566
|
1566
|
1548
|
1548
|
| Max. Rated VA (Volt-Amp) |
1186
|
1172
|
1598
|
1598
|
1579
|
1579
|
|
Efficiency (%) |
80
|
81
|
83
|
83
|
84
|
84
|
|
Power Factor |
0.98
|
0.98
|
0.98
|
0.98
|
0.98
|
0.98
|
|
Leakage Current (mA) |
0.43
|
0.50
|
0.90
|
0.96
|
1.00
|
1.04
|
|
Maximum Inrush Current (A peak) |
100
|
100
|
100
|
100
|
100
|
100
|
|
Maximum Inrush Current duration (mS) |
10
|
10
|
10
|
10
|
10
|
10
|
| System Specifications | ||
| To determine power specifications for various system configurations, please use the online HP Power Calculator Tool referenced below. |
|
Power cord requirements
|
Tower model comes with local power cord
|
Option no. See chart below
Spare no. See chart below |
|
|
Rack models come with PDU jumper cord and/or local power
cord.
|
Option no. See chart below
Spare no. See chart below |
|
NOTES:
* - To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc/power%20calculator%20catalog.xls - Click on the Power Calculator for the server of interest. Example: ML570 G3 - There are certain Dual-core, lowline, max configurations
that are not supported. All highline |
||
| Standard Tower Model Power Cords | Description | |
| Nema 5-15P to IEC320-C19 | ||
| Standard Rack Model Power Cords | Description | |
|
|
Nema 5-15P to IEC320-C19 | |
| IEC320-C14 to IEC320-C19 | ||
| Optional Power Cords and Jumper Cords | Description | Option Power Cord Part Number |
| Nema 5-15P to IEC320-C19 | 235603-001 | |
| Nema 6-20P to IEC320-C19 | 235604-001 | |
| IEC320-C19, 20A, 250V, US | 340653-001 | |
| WW | IEC320-C14 to IEC320-C19 Jumper (10A, IEC, 6ft/2.0m) | 313227-B21 |
| WW | IEC320-C14 to IEC320-C19 Jumper (10A, IEC, 12ft/3.6m) | 313228-B21 |
| IEC320-C19 to IEC320-C20 Jumper (16A, IEC, 8ft/2.5m) | 295633-B22 |
|
|
Technical Specifications
| System Unit | Tower Dimensions (HxWxD) (with feet/bezel) |
20 x 11.1 x 28.8 in (50.8 x 28.2 x 73.2 cm) | |
| Rack Dimensions (HxWxD) (with bezel) |
11.1 x 19.0 x 28.0 in (28.2 x 48.3 x 71.1 cm) | ||
| Maximum Weight | 137 lb (62.14 kg) | ||
| Input Requirements (per power supply) |
Range Input Voltage | 100 to 127 VAC/200 to 240 VAC | |
| Rated Input Frequency | 47 to 63 Hz | ||
| Input Power | 1163W @ 110 VAC; 1598W @ 200 VAC | ||
| Rated Input Current | 12A / 8A | ||
| BTU Rating | BTU/hr (max) | 5457 BTU/hr | |
| SCSI Connectors | Two internal HD68 connectors (supporting Ultra320) | ||
| One external VHDCI connector (supporting Ultra320) | |||
| One SCSI knockout | |||
| Power Supply Output Power (per power supply) | Rated Steady-State Power | 910W/1300W | |
| Maximum Peak Power | 960W/1420W for 10 sec max | ||
| Temperature Range |
Operating |
50° to 95° F (10° to 35° C) | |
| Non-operating |
-20° to 140° F (-29° to 60° C) | ||
| Shipping |
-22° to 122° F (-30° to 50° C) | ||
| Relative Humidity (non-condensing) | Operating |
10% to 70% | |
| Non-operating |
5% to 95% | ||
| Maximum Wet Bulb Temperature |
101.7° F (38.7° C) | ||
| Acoustic Noise |
Listed are the declared A-WEIGHTED SOUND POWER (LWAd) and average bystander
position A-WEIGHTED SOUND PRESSURE LEVEL (LpAm) when the product is operating
in a 23°C ambient environment. Noise emissions were measured in accordance
with ISO 7779 (ECMA 74, 7th edition) and declared in accordance with ISO
9296 (ECMA 109). |
||
|
|
|||
| Slimline CD-RW/DVD-ROM 8X/24X Combo Drive (Multibay) | Disk | Disk formats | DVD (single and double layer), DVD-5, DVD-9, DVD-10, DVD-R, CD-ROM Mode 1 & 2, CD-DA, CD-XA (mode 2, Form 1 & 2), CD-I (Mode 2, Form 1 & 2), CD-I ready, CD-Bridge, CD-R, Photo CD( single and multi-session) |
| Capacity | 4.7 GB (DVD-5), 8.5 GB (DVD-9), 9.4 GB (DVD-10), 550MB (Mode 1, 12 cm), 640 MB (Mode 2, 12 cm), 180 MB (8 cm) | ||
| Block Size | Mode 0 |
2352 bytes | |
| Mode 1 |
2352, 2340, 2336, 2048 bytes | ||
| Mode 2 |
2352, 2340, 2336, 2048 bytes | ||
| DVD |
2048 bytes | ||
| Access Times (typical) | Random | <110 ms CD <180 ms DVD |
|
| Full-Stroke | <200 ms CD <300 ms DVD |
||
| Diameter |
12 cm, 8 cm (4.70 in, 3.15 in) | ||
| Thickness |
1.2 mm (0.05 in) | ||
| Track pitch | 0.74 µm (3.15 x 10-7 in)
DVD-ROM 1.6 µm (6.3 x 10-7 in) CD-ROM |
||
| Data Transfer Rate | Sustained | 4463 - 10,800 KB/2 (8x CAV DVD mode), 150 KB/s (sustained 1x CD-ROM), 1552 - 3600 KB/s (24x CAV CD-ROM) | |
| Burst | 16.6 MB/s with DMA support | ||
| Cache Buffer | |||
| Start-up Time (typical) | < 10 seconds | ||
| Stop Time | < 5 seconds (single); < 30 seconds (multi-session) |
||
| Laser Parameters | Type | Semiconductor Laser GaAs | |
| Wave Length | 700 ± 25 nm | ||
| Divergence angle | 53.5° ± 1.5° | ||
| Output Power | 0.14 mW | ||
| Operating Conditions | Temperature | 41° to 118° F (5° to 45° C) | |
| Humidity | 5% to 90% | ||
| Dimensions |
(HxWxD, maximum) |
0.5 x 5.2 x 5.2 in (12.7 x 132.08 x 132.08 mm) | |
| Weight | 0.75 lb (0.34 kg) | ||
|
|
|||
| Embedded NC7782
PCI-X Gigabit Server Adapter |
Network Interface | 10Base-T/100Base-TX/1000Base-TX |
|
| Compatibility | IEEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T IEEE 802.3u 100Base-TX |
||
| Data Transfer Method | 64-bit bus-master PCI-X | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000 Mb/s | ||
| Connector | Two RJ-45 |
||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) |
|
| 100Base-TX | Category 5 or higher UTP; up to 328 ft (100 m) |
||
| 1000Base-TX | Category 5 or higher UTP; up to 328 ft (100 m) |
||
|
|
|||
| Smart Array P600
Controller (SAS models only) |
Disk Drive and Enclosure Protocol
Support |
3 Gbps SAS (Serial Attached SCSI) 1.5 Gbps SATA (Serial AT Attachment) |
| Architecture |
1.5 Gb SATA | |
| SAS Connectors |
1 internal SFF8484 & 1 external
SFF8470 / internal SFF8484 shared x4 Wide SAS Ports 12 Gbps per x4 Wide SAS Port (4 x 3 Gbps) |
|
| Data Transfer Method |
64-bit wide, PCIX 133 MHz (1 GB/s maximum bandwidth) | |
| PCI Bus Speed | PCIX-133 and 3.3 volt PCI compatibility only | |
| Memory Bus Speed | DDR-266 and 72 bit wide bus | |
| PCI |
64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth) | |
| Simultaneous Drive Transfer Ports | PCI-X and 3.3 volt PCI compatibility only | |
| Port Transfer Rate | 2 x4 Wide SAS Ports | |
| Software upgradeable Firmware |
12 Gb/s per x4 Wide SAS Port (4 x 3 Gb/s) | |
| Cache Memory |
Yes | |
| Logical Drives Supported |
256 MB Read/Write (512-MB module
upgrade available); ECC protection, battery-backed, and removable |
|
| Maximum Capacity |
Up to 32 logical drives Up to 2.2 TB per logical drive |
|
| Memory Addressing |
2.7 TB (38 x 72 GB) 64-bit, supporting servers memory greater than 4 GB |
|
| RAID Support | RAID 6 (Advanced Data Guarding) RAID 5 (Distributed Data Guarding) RAID 1+0 (Striping & Mirroring) RAID 0 (Striping) |
|
| Upgradeable Firmware Disk Drive and |
4-MB flashable ROM | |
| Enclosure Protocol Support | 3 Gb SAS and 1.5 Gb SATA | |
|
|
||
| Integrated Dual Channel Ultra320 SCSI Adapter | Drives Supported | Up to 15 SCSI devices per channel |
| Data Transfer Method | 64-bit PCI bus-master | |
| SCSI Channel Transfer Rate | 320 MB/s per channel | |
| Maximum Transfer Rate per PCI Bus (peak) | 400 MB/s | |
| SCSI Termination | Active Termination | |
| SCSI Connectors | 1 external (VHDCI), 2 internal (68-pin) | |
|
|
||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |