Overview
|
HP StorageWorks 50 Modular Smart Array Enclosure |
|
The HP StorageWorks 50 Modular Smart Array (MSA50) Enclosure is a 1U Serial Attach SCSI(SAS) disk drive storage enclosure supporting Small Form Factor(SFF) SAS or Serial ATA(SATA) drives. This enclosure delivers industry-leading data performance, availability, storage density, and upgradeability to meet customers' demanding and growing storage needs. The all new SFF drive carrier is designed to support the new Universal form factor hard drive in either SAS or SATA. This new form factor provides optimized performance per U of space while delivering unparalleled power consumption. The MSA50 enclosure supports direct attach storage to HP ProLiant and Integrity Servers. The MSA50 supports the cascading of shelves in a 1+1 configuration to allow a maximum of 20 SFF drives in a 2U configuration attached to a single controller port. This single controller port incorporates four lanes for a total max throughput of 12Gb/s for SAS. |
![]() | |||
| 1. | Expansion slot for potential future second I/O | 6. | Power button/LED |
| 2. | Fan | 7. | UID button/LED |
| 3. | Hot-plug power supply | 8. | Hot-plug SAS or SATA hard drive bays |
| 4. | Hot-plug power supply | 9. | Access panel |
| 5. | I/O module | ||
| | |||
| Models | ||
| The MSA50 design allows for the mix of SAS and SATA drives in the same enclosure at the same time and is tailored to the needs of HP server customers who require optimized performance per U of rack space. | ||
|
Model MSA50
|
HP StorageWorks 50 Modular Smart
Array Enclosure (NA,EMEA,AP) NOTE: Rack-mountable 10 SFF drive enclosure with single I/O module, redundant hot plug power supplies and hot plug fans. |
364430-B21
|
| HP StorageWorks 50 Modular Smart
Array Enclosure (Japan) NOTE: Rack-mountable 10 SFF drive enclosure with single I/O module, redundant hot plug power supplies and hot plug fans. |
364430-291
|
|
|
NOTE: For complete compatibility information, refer to the Specifications section of this document. SAS/SATA performance requires a compatible SAS controller. This is noted in the product documentation. |
||
|
|
Product Highlights
| Customer Benefits |
Higher Performance per U of Rack Space
|
The Serialized nature of SAS combined with the highest spindle count per U of rack space allows the MSA50 to achieve the greatest I/Os per second when compared to parallel SCSI. |
| Price Sensitivity | The MSA50 will be the first SAS/SATA SFF JBOD product that will offer a level of availability sufficient for the Enterprise and a price structure that is attractive to SMB. | |
| Investment Protection | The MSA50 has the future potential to upgrade from 3GB to 6GB SAS, as well as mix and match SAS or SATA drives within the same enclosure. Thus making technology transitions simple and cost effective. | |
| Reduced Spares Inventory | Universal SFF drives and similar physical characteristics between SAS and SATA drives allow customers to mix/match SAS and SATA in the same enclosure and allow the same drives to be used in servers and external storage. | |
|
|
||
| Key Features | Features of the MSA50 include: | |
| SFF
(SAS/SATA) support Delivering data transfer rates up 3Gb/s for SAS and
1.5Gb/s for SATA NOTE: SAS/SATA performance requires a compatible SAS controller. This is noted in the product documentation. | ||
| ||
| Easy removal of parts provides better serviceability. No tools are required! | ||
| Upgradeability |
Potential Upgrade path for a HP StorageWorks MSA50 is
as easy as swapping out the I/O Module on the back of the unit. The unit
must be powered down to replace the I/O Module.
|
|
|
|
| Mix and Match of Hard Drive Types |
A benefit of SAS and SATA is the use of a common physical connection which allows for both drive types to be mixed together on the same backplane. This common backplane allows customers the choice of using SAS and/or SATA and helps deliver HP's message of industry leading innovation, reliability, adaptability, and performance by allowing customers to choose the reliability of SAS or the lower cost of SATA for tiered storage. |
|
|
|
| Hot Pluggable |
Hot pluggable technology is designed into drives, fans and redundant power supplies. Hot pluggable components can be replaced without powering down the storage system or stopping I/O operations. This feature significantly enhances data availability. |
|
|
|
| Auto SAS ID Selection |
SAS ID is automatically set when a drive is inserted into a drive bay (See drawing on top of unit for bay numbering). |
|
|
|
| LED Indicators |
Front panel LEDs indicate drive activity, required drive service, and power, giving a quick visual assessment of overall system storage status. |
|
|
|
| Rack Density |
The MSA50 Enclosure has a 1U height. |
|
|
|
| Environment Monitoring Unit (EMU) |
Each MSA50 model is equipped with an EMU that constantly monitors the enclosure, the power supplies, and fans to ensure suggested operating tolerances are maintained. |
|
|
|
| I/O Module |
The single I/O module installed allows one SAS controller to access all drives in the MSA50. |
|
|
|
| Fault Tolerance |
With redundant power supplies and fans, the MSA50 provides a high level of system availability. Using an internal host based controller, the MSA50 can be configured for RAID levels 0, 1, 1 + 0, 5, 6 (RAID ADG) when using a HP Smart Array RAID controller. |
|
|
|
| Manageability | The MSA50 is managed by HP Systems Insight Manager. |
|
|
|
| Compatibility and Integration Testing |
Intensive compatibility and performance testing with HP ProLiant servers ensures the highest level of integration available in the industry. For a complete list of supported HP servers and workstations, please refer to the QuickSpecs and/or User Guide of the array controller or Host Bus adapter that you are planning to use. The list of supported array controllers and SAS adapters is provided under "Related Options, Controllers". |
|
|
|
| Product Kit Contents |
Redundant power supplies, single I/O module, 9 drive blanks, warranty card, mounting hardware, Enclosure user guide, HP SmartStart CD Kit, documentation CD, one 2 Meter SAS external cable and two Nema 5-15 to C13 and two IEC320-C14 to -C13 power cords. NOTE: The included SAS cable is only
for the P600 controller. |
|
|
|
| Warranty |
Three-year limited parts only warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers. In addition 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services NOTE: The MSA50 has a limited 3 year
parts only warranty. The SAS drives have a 3 year warranty; SATA drives
have a 1 year warranty |
| Hard drive Pre-Failure Warranty: When used with any one of the StorageWorks Smart Array Family controllers and monitored under HP Systems Insight Manager (v4.20 or later), HP hard drives are supported by a Pre-Failure (replacement) Warranty. |
|
|
Service and Support, HP Care Pack, and Warranty Information
| Software Product Services |
Standalone telephone support
|
| Rights to new license version | |
| Media and documentation updates | |
|
|
|
| Hardware Product Services | Installation services |
| On-site maintenance (includes warranty support) | |
| Response time upgrades during the warranty period | |
| Post-warranty coverage | |
| RAID setup and performance consulting via statement of work | |
| For additional hardware installation
and maintenance information, please refer to the URL listed below: http://www.hp.com/hps/carepack/services/cp_installation.html |
|
|
|
|
| Warranty Upgrade Options | Response Upgrade on-site response from next business day to same day 4 hours |
| Coverage Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days | |
| Duration Select duration of coverage for a period of 1, 3, or 5 years | |
|
|
|
| HP Services and Support | HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. | |
| HP Care Pack is not available for less than the product's warranty duration. | ||
| HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required. | ||
| HP
Care Pack services are prepaid. For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL http://www.hp.com/hps/carepack | ||
| Care Pack services
provide a range of life cycle support options that let you choose the service
levels that meet your business requirements, from basic to mission-critical. A
full range of HP Care Pack hardware and software services are available including:
NOTE:
For more information on HP Care Pack services, contact any of our worldwide sales
offices, resellers or visit our worldwide website at: http://www.hp.com/hps/carepack
NOTE: For additional information on Server Services, Rack and Power Options, please visit: http://h20219.www2.hp.com/services/cache/111072-0-0-225-121.html NOTE:
The information contained herein is subject to change without notice and is provided
"as is" without warranty of any kind. | ||
| | ||
| Components | The following brick level options/components do not have individual HP Care Pack Services. These items will be included in product HP Care Pack Services into which they are installed. | ||||
| Disk Drives | Tape Drives | CD/DVD ROM | SCSI Hubs in SBBs | Adapters | |
| Bus Converters | Backplane RAID Controllers | Power Supplies | Cabling | Fans | |
|
|
Options
| NOTE: Some of the options listed below may be discontinued. |
|
| Hard Drives | SFF Serial Attached SCSI (SAS) Hard Drives | |||
| HP 36GB 3G SAS 10K SFF SP HDD |
375859-B21 | |||
| HP 72GB 3G SAS 10K SFF SP HDD |
375861-B21 | |||
| HP 146GB 3G SAS 10K SFF SP HDD |
431958-B21 | |||
| HP 36GB 3G SAS 15K SFF SP HDD |
431933-B21 | |||
| HP 72GB 3G SAS 15K SFF SP HDD |
431935-B21 | |||
| SFF Serial-ATA (SATA) Hard Drive | ||||
| HP 60GB 1.5G SATA 5.4K SFF HDD |
379306-B21 | |||
| HP 120GB 1.5G SATA 5.4K SFF HDD |
431786-B21 | |||
| HP 250GB 3G 5.4K 2.5 inch SATA SFF ETY HDD | 460355-B21 | |||
| NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility information (http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data. | ||||
| | ||||
| Storage Controllers | SAS Controller | ||
| HP Smart Array P800 Controller /512 BBWC Controller |
381513-B21 | ||
| HP Smart Array P600/256 BBWC Controller |
337972-B21 | ||
| Smart Array E500 controller |
435129-B21 | ||
| 512MB DDR BBWC Upgrade (P600 Controller) |
372538-B21 | ||
| NOTE:
Please see the following Controller QuickSpecs for Technical Specifications
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak
Data Transfer Rate, SCSI Ports, Drives supported, Cache, RAID support, and additional
information: http://h18000.www1.hp.com/products/quickspecs/12247_div/12247_div.html (Smart Array P600 Controller) http://h18004.www1.hp.com/products/servers/ proliantstorage/arraycontrollers/smartarrayp800/index.html (Smart Array P800 Controller) NOTE: The Smart Array P600 supports the cascading of shelves in a 1+1 configuration to allow a maximum of 20 drives in a 2U configuration behind or the HP Smart Array P600 controller as the P600 has only a single external port. NOTE: See your server and controller compatibility matrix for details on controller and server compatibility. http://h18004.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html NOTE: The Smart Array controller E500 offers RAID 0, 1 and 0+1 and can be upgraded to RAID 5 with battery-backed write cache (BBWC) module - 383280-B21 | | ||
| SAS Cable Options | Cables used for connecting the HP Smart Array P600/256 BBWC Controller (P/N 337972-B21) to MSA50 | ||
| HP External SAS Cable 2m |
389668-B21
|
||
| HP External SAS Cable 2m |
389668-B21#0D1
|
||
| HP External SAS Cable 4m |
389671-B21
|
||
| HP External SAS Cable 4m |
389671-B21#0D1
|
||
| Cables used for connecting the HP Smart Array P800/512 BBWC Controller (P/N 381513-B21) or to the HP Smart Array E500 (P/N 435129-B21) to MSA50 | |||
| SAS 4x to Mini SAS 4x 2M |
419571-B21
|
||
| SAS 4x to Mini SAS 4x 2M |
419571-B21#0D1
|
||
| SAS 4x to Mini SAS 4x 4M |
419572-B21
|
||
| SAS 4x to Mini SAS 4x 4M |
419572-B21#0D1
|
||
| SAS 4x to Mini SAS 4x 6M |
419573-B21
|
||
| SAS 4x to Mini SAS 4x 6M |
419573-B21#0D1
|
||
|
|
|||
| Rack Options | HP 5642 Rack-Unassembled |
358254-B21
|
|
| HP S10614 (14U) Rack Cabinet Shock Pallet |
292302-B22
|
||
| HP 10842 (42U) Rack Cabinet Pallet |
257415-B21
|
||
| HP 10842 (42U) Rack Cabinet Shock Pallet |
257415-B22
|
||
| HP 10647 (47U) Rack Cabinet Pallet |
245160-B21
|
||
| HP 10647 (47U) Rack Cabinet Crated |
245160-B23
|
||
| HP 10622 (22U) Rack Cabinet Pallet |
245163-B21
|
||
| HP 10622 (22U) Rack Cabinet Crated |
245163-B23
|
||
| M-Series Rack Rail Kit Option (2-5-2) | 3R-A5281-AA | ||
| NOTE: It is mandatory
to use a shock pallet in order to ship racks with equipment installed. NOTE: Each Modular Storage Cabinet (42U, 41U, 36U, and 22U) comes with redundant 220 to 240V PDUs and power cables to accommodate Modular Array configurations. For more details on Modular Array solutions, see: http://h18006.www1.hp.com/storage/arraysystems.html. |
|||
|
|
|||
| HP Services and Support | 1 Year Next Day HW |
HA101A1-7GT
|
|
| 1 Year 4h 13x5 HW |
HA103A1-7GT
|
||
| 1 Year 4h 24x7 HW |
HA104A1-7GT
|
||
| 1 Year 6h CTR HW |
HA105A1-7GT
|
||
| 1 Year Support Plus |
HA109A1-7GT
|
||
| 1 Year Support Plus 24 |
HA110A1-7GT
|
||
| 3 Year Next Day HW |
HA101A3-7GT
|
||
| 3 Year 4h 13x5 HW |
HA103A3-7GT
|
||
| 3 Year 4h 24x7 HW |
HA104A3-7GT
|
||
| 3 Year 6h CTR HW |
HA105A3-7GT
|
||
| 3 Year Support Plus |
HA109A3-7GT
|
||
| 3 Year Support Plus 24 |
HA110A3-7GT
|
||
| Installation |
HA113A1-564
|
||
| 3 Year NBD 9x5 (Electronic) |
U8128E
|
||
| 3 Year 4H 13x5 (Electronic) |
U8129E
|
||
| 3 Year 4H 24x7 (Electronic) |
U8130E
|
||
| 3 Year 6H CTR (Electronic) |
U8131E
|
||
| 1 Year NBD 9x5 (Electronic) |
U8151E
|
||
| 1 Year 4H 13x5 (Electronic) |
U8152E
|
||
| 1 Year 4H 24x7 (Electronic) |
U8153E
|
||
| 1 Year 6H CTR (Electronic) |
U8154E
|
||
| Installation (Electronic) |
U8132E
|
||
| NOTE: For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL http://www.hp.com/hps/carepack | |||
|
|
|||
|
|
Technical Specifications
| HP StorageWorks Modular Smart Array 50 Enclosure | Shipping Dimensions (HxWxD) |
12 x 23.5 x 33 in (30.24 x 59.22 x 83.16 cm) |
| Weight (unloaded) |
20 lb (9.07 kg) | |
| Weight (loaded) | 30 lb (13.61kg) | |
| Redundant Power Supply, 180 watts | Shipping Dimensions (HxWxD) | 12.75 x 8 x 3.75 in (32.13 x 20.16 x 9.45 cm) |
| Protocol Support | 3Gb/s SAS | |
| 1.5Gb/s SATA | ||
| O/S Support | Defined by specific HP array controller or SAS/SATA adapter used; please refer to the QuickSpecs and/or User Guide of the specific array controller or adapter | |
| Buttons/LED Indicators (on front right panel-listed top to bottom) | UID Button (top) | |
| System Field Replaceable Unit (FRU) LED | ||
| EMU Status LED | ||
| Fault LED (bottom) | ||
| Drive LED Indicators (on drive trays) | Drive LED (top) - On-line/Activity | |
| Drive Failure LED (bottom) - Drive Fault/Locate | ||
| Enclosure Button/ LED Indicators (back of unit) | UID Button (top) | |
| System FRU (middle) | ||
| EMU Status LED (bottom) | ||
| Input Requirements | Nominal Line Voltage | 110 to 240 V AC |
| Range Line Voltage | 90 to 264 V AC | |
| Line Frequency | 47 to 63 Hz | |
| Typical Input Current | 2.3A at 120 V AC | |
| Relative Humidity (non-condensing) | Operating | 10% to 90% |
| Shipping | 5% to 90% | |
| I/O Module Connector | SAS SFF 8470 Connector | |
| Power | 180 Watts per supply (load) | |
| Temperature Range | Operating | 50° to 94° F (10° to 35° C°) |
| Shipping | -40° to 151° F (-40° to 66° C) | |
| NOTE: To maintain proper cooling and airflow, a drive blank or drive must occupy all bays during operation. | ||
|
|
||
|
© Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. |