Overview
| HP Cluster Platform 3000 and HP Cluster Platform 4000 |
![]() |
| An HP Cluster Platform 3000 or 4000 with 128 compute nodes (HP ProLiant DL160 G6 or HP ProLiant DL165 G5 Servers) and an InfiniBand high-speed interconnect. The configuration consists of 3 compute building blocks (CBB) racks containing 114 compute nodes and Ethernet switches, and 1 utility building block (UBB) rack. The UBB contains 1 control node, 14 compute nodes, an InfiniBand switch, a TFT display, and the root Ethernet switches. |
| |
| What's New |
|
| |
| At A Glance |
HP Cluster Platforms are available from HP Sales Representatives and HPC-Certified Resellers, utilizing Cluster Platform configurators and menus. Basic Architecture Components: Nodes
Basic Architecture Components: Networks
Basic Architecture Components: Storage
Basic Architecture Components: Infrastructure
Basic Architecture Components: Software The following components are available on the HP Cluster Platform product menu, and can be factory installed by HP:
|
| |
| Summary Table of Cluster Platform Options |
| |
Control node |
Compute node |
Utility node |
Visualization node |
Cluster interconnect |
| Cluster Platform
3000 |
HP ProLiant DL160 G6
HP ProLiant DL380 G6 |
HP ProLiant DL160 G6
|
HP ProLiant DL380 G6
|
HP xw8400
HP ProLiant DL160 G6 |
Gigabit Ethernet, InfiniBand
|
| Cluster Platform 3000BL |
HP ProLiant BL280c G6
HP ProLiant BL2x220c G5 HP ProLiant BL460c G6 HP ProLiant DL160 G6 HP ProLiant DL380 G6 |
HP ProLiant BL280c G6 |
HP ProLiant BL460c G6 HP ProLiant DL380 G6 | |
Gigabit Ethernet, InfiniBand
|
| Cluster Platform
4000 |
HP ProLiant DL165 G5
HP ProLiant DL385 G5p HP ProLiant DL585 G5 |
HP ProLiant DL165 G5
HP ProLiant DL585 G5 |
HP ProLiant DL385 G5p
|
HP xw9400
HP ProLiant DL165 G5 |
Gigabit Ethernet, InfiniBand
|
| Cluster Platform 4000BL |
HP ProLiant BL465c G5
HP ProLiant DL385 G5p HP ProLiant DL165 G5 |
HP ProLiant BL465c G5
|
HP ProLiant BL465c G5
HP ProLiant DL385 G5p HP ProLiant DL585 G5 | |
Gigabit Ethernet, InfiniBand
|
|
|
Standard Features (HP Cluster Platform 3000 and 4000: Dense and Modular Design)
| Packaging
for HP Cluster Platform 3000 and 4000-Dense Design |
|
| Each dense cluster includes one Utility Building Block (UBB) cabinet, which houses the control node, RKM, and the optional high-performance interconnect switch, and utility nodes. Other cabinets are used to house the compute nodes. Compute nodes may be integrated into the UBB, as space permits, in dense configurations. | |
| Total utility node count in dense configurations cannot exceed 7 nodes | |
| Each cabinet includes two ProCurve switches: one for administrative network, and one for console network. | |
| Visualization nodes can be ordered with a dense or modular cluster, but the maximum number of nodes per cabinet will be reduced. The visualization nodes based on HP personal workstations will be placed in separate cabinets (VBB), as described below. HP ProLiant based visualization nodes will be placed in the compute building blocks (CBB). Node count limitation applies in that case. | |
| Optional MSA2000 storage subsystem, with up to 3 expansion disk shelves. Optional MSA60 disk shelves attached to HP Smart Array P800 controllers. | |
| Delivered on shock resistant pallet | |
| Servers, Switches, RKM & storage are rack installed | |
| Fully pre-wired and factory integrated | |
| | |
| Packaging for HP Cluster Platform 3000 and 4000- Modular Design, HP Cluster Platform 3000BL and 4000BL | HP Cluster Platform modular
solutions are organized in building blocks that can be easily replicated to build
large-scale clusters.
|
| Each CBB and UBB includes two ProCurve switches: one for administrative network, and one for console network. Console interfaces for the UXR and IBB are connected to the root switch housed in the UBB. VBB cabinets have one branch administration switch in every other cabinet and no console switch. One 24-port ProCurve administration switch services up to 16 nodes in 2 VBB cabinets. | |
| Each UBB, UXR and CBB includes three or four PDUs with rackmount servers. With blade servers, UBB and CBB include two PDUs are utilized in each IBB (three PDUs for Quadrics based IBB). The VBB uses a dual power monitoring PDU. | |
| Delivered on shock resistant pallet | |
| Servers, switches, RKM & storage are rack installed | |
| Fully pre-wired and factory integrated | |
| | |
| HP Cluster Platforms 3000: Dense and Modular Design | ||
| Control Node (HP Cluster Platform 3000) | Select
One Server |
HP ProLiant DL380 G6 Server (recommended for PCI slot availability) |
| Choose Processor Option | All currently shipping processors for each control node are available. Select one or two processors | |
| Memory Options | HP ProLiant DL160 G6 is available with DDR3 memory. HP ProLiant DL380 G6 is available with DDR3 memory. Maximum memory will vary by server. | |
| DVD Drive Options | DVD is required option for control nodes in HP Cluster Platforms | |
| Disk Options | One disk minimum for control nodes. HP ProLiant DL380 G6 Server available with up to eight SATA or SAS small form factor drives, or up to six SATA or SAS Large Form Factor drives.. HP ProLiant DL160 G6 available with up to four NHP SATA, HP SATA or HP SAS drives. | |
| PCI - I/O Options | Control nodes feature option to connect to the high-performance cluster interconnect. Other PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. When InfiniBand interconnect selected, control node is configured with PCI-Express supported adapter | |
| Redundant Power Supply | Recommended for control nodes | |
| | ||
| Compute Node | Specify Node per Pool and Number of Nodes |
HP ProLiant DL160 G6 Server |
| Choose Processor Option |
All currently shipping processors for each compute node are available. Select one or two processors. | |
| Memory Options | HP ProLiant DL160 G6 is available with DDR3 memory. Maximum memory is 144GB per node. | |
| DVD Drive Options | Optional | |
| Disk Options | One to four NHP SATA, HP SATA or HP SAS Drives. HP (Hot Plug) Drives requires low profile PCI adapter and an HDD. | |
| PCI - I/O Options | When InfiniBand interconnect selected, compute nodes are configured with PCI-Express supported adapter. Other PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. | |
| Redundant Power Supply | Not offered for compute nodes | |
| Utility Node | Select Node Configuration per Pool and Number of Nodes | HP ProLiant DL380 G6 server
NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/10480.html |
| Choose Processor Option | All currently shipping processors for the HP ProLiant DL380 G6 node are available. Select one or two processors. | |
| Memory Options | HP ProLiant DL380 G6 is available with up to 144 GB DDR3 memory. | |
| DVD Drive Options | DVD is optional | |
| Disk Options | One disk minimum for utility nodes. HP ProLiant DL380 G6 Server available with up to eight SATA or SAS small form factor drives, or up to six SATA or SAS Large Form Factor drives. | |
| PCI - I/O Options | When InfiniBand interconnect selected, compute nodes are configured with PCI-Express supported adapter. PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. | |
| Redundant Power Supply | Optional | |
| Visualization Node | Select Node Configuration
per Pool and Number of Nodes |
HP xw8400 Workstation or HP
ProLiant DL160 G6 NOTE: Complete information on the workstation can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/10480.html |
| Choose Processor Option | All currently shipping processors for the HP xw8400 or HP ProLiant DL160 G6 are available. Select one or two processors | |
| Memory Options | HP xw8400 are available with
up to 32 GB DDR2 FB-DIMM memory. HP ProLiant DL160 G6 are available with up to 144GB DDR3 memory. |
|
| DVD Drive Options | Required with the HP Workstation | |
| Disk Options | One disk minimum. HP xw8400 available with up to 4 SAS drives or 5 SATA drives. HP ProLiant DL160 G6 available with up to four SAS or SATA drives. |
|
| PCI - I/O Options | Based on interconnect selected, visualization nodes are configured with supported adapter. PCI options include an additional Gigabit Ethernet interface. | |
| Graphics | Supported PCI-Express 16X graphics
adapters are NVIDIA FX1500, FX3500, FX4600 and FX5500. Only NVIDIA FX3700 is supported on HP ProLiant DL160 G6. |
|
| Redundant Power Supply | Not available. | |
| | ||
| HP Cluster Platforms 3000BL | ||
| Control Node (HP Cluster Platform 3000BL) | Select One Server |
HP ProLiant DL380 G6 Server (recommended for PCI slot availability) |
| Choose Processor Option |
All currently shipping processors for each control node are available. Select one or two processors | |
| Memory Options | HP ProLiant DL160 G6, HP ProLiant DL380 G6, HP ProLiant BL280c G6 and HP ProLiant BL460c G6 are available with DDR3 memory. HP ProLiant BL2x220c G5 is available with PC2-5300 memory. Maximum memory will vary by server. | |
| DVD Drive Options | DVD is required option for control nodes in HP Cluster Platforms | |
| Disk Options | One disk minimum for control nodes. HP ProLiant DL380 G6 Server available with up to eight HP SATA or SAS small form factor drives, or up to six SATA or SAS Large Form Factor drives. HP ProLiant DL160 G6 available with up to four NHP SATA, HP SATA or HP SAS drives. HP ProLiant BL280c G6 available with up to two NHP SATA or SAS drives. HP ProLiant BL2x220c G5 available with up to one NHP SATA drive per server. HP ProLiant BL460c G6 available with up to two HP SATA or SAS drives. | |
| PCI - I/O Options | Control nodes feature option to connect to the high-performance cluster interconnect. Other PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. When InfiniBand interconnect selected, control node is configured with PCI-Express supported adapter | |
| Redundant Power Supply | Recommended for control nodes | |
| | ||
| Compute Node | Specify Node per Pool and Number of Nodes |
HP ProLiant BL280c G6 |
| Choose Processor Option |
All currently shipping processors for each utility node are available. Select one or two processors, two or four per HP ProLiant BL2x220c G5 blade. | |
| Memory Options | HP ProLiant BL280c G6 and HP ProLiant BL460c G6 are available with DDR3memory. HP ProLiant BL2x220c G5 is available with PC2-5300 memory. Maximum memory will vary by server. | |
| DVD Drive Options | DVD is optional | |
| Disk Options | HP ProLiant BL280c G6 available with up to two NHP SATA or SAS drives. HP ProLiant BL2x220c G5 available with up to one NHP SATA drive per server. HP ProLiant BL460c G6 available with up to two HP SATA or HP SAS Small Form Factor drives. | |
| PCI - I/O Options | When InfiniBand
interconnect selected, compute nodes are configured with mezzanine supported adapter.
PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface.
Optional | |
| Redundant Power Supply | Not applicable | |
| Utility Node | Select Node Configuration per Pool and Number of Nodes | HP ProLiant DL380 G6 server HP ProLiant BL460c G6 NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/12534.html
|
| Choose Processor Option | All currently shipping processors for the HP ProLiant DL380 G6 node are available. Select one or two processors | |
| Memory Options | HP ProLiant DL380 G6 is available with up to 144 GB DDR3 memory | |
| DVD Drive Options | DVD is optional | |
| Disk Options | One disk minimum for utility nodes. HP ProLiant DL380 G6 Server available with up to eight SATA or SAS small form factor drives, or up to six SATA or SAS Large Form Factor drives. | |
| PCI
- I/O Options | When InfiniBand interconnect selected, compute nodes are configured with PCI-Express supported adapter. PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. | |
| Redundant Power Supply | Optional | |
| | ||
| HP Cluster Platforms 4000: Dense and Modular Design | ||
| Control Node (HP Cluster Platform 4000) | Select One Server |
HP ProLiant DL385 G5p Server (recommended for PCI slot availability) |
| Choose Processor Option |
All currently shipping processors for each control node are available. Select one or two processors (two or four with HP ProLiant DL585) | |
| Memory Options | HP ProLiant DL165 G5 is available with up to 16GB PC2-6400 memory per processor and HP ProLiant DL385 G5p nodes is available with up to 64GB PC2-5300 or 32GB PC2-6400 memory per processor. HP ProLiant DL585 G5 is available with up to 128 GB PC2-6400 Registered DIMM memory. | |
| DVD Drive Options | DVD is required option for control nodes in HP Cluster Platforms | |
| Disk Options | One disk minimum for control nodes. HP ProLiant DL385 G5p Server available with up to eight SAS or SATA drives, or up to six SATA or SAS Large Form Factor drives. HP ProLiant DL165 G5 available with up to four SATA (NHP or HP) or SAS HP drives. Hot Plug drives require low profile SAS PCI adapter and an HDD backplane when more than two drives are configured. HP ProLiant DL585 G5 Server available with up to eight SAS or SATA drives. | |
| PCI - I/O Options | Control nodes feature option to connect to the high-performance cluster interconnect. Other PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. When supported on selected control node, PCI-Express riser cards are optional with InfiniBand | |
| Redundant Power Supply | Recommended for control nodes | |
| | ||
| Compute Node | Specify Node per Pool and Number of Nodes |
HP ProLiant DL585 G5 Server |
| Choose Processor Option |
All currently shipping processors for each compute node are available. Select one or two processors (two or four with HP ProLiant DL585) | |
| Memory Options | HP ProLiant DL585 G5 is available with up to 128GB PC2-6400 Registered DIMM memory. HP ProLiant DL165 G5 is available with up to 16GB PC2-6400 memory per processor | |
| DVD Drive Options | Optional | |
| Disk Options | HP
ProLiant DL585 G5 Server available with up to eight SAS or SATA drives. HP ProLiant
DL165 G5 available with up to four SATA (NHP or HP) or SAS drives. NOTE: HP (Hot Plug) options on HP ProLiant DL165 G5 requires low profile PCI adapter. HDD backplane required when more than two drives are configured on this server. | |
| PCI - I/O Options | When non Gigabit Ethernet interconnect selected, compute nodes are configured with supported adapter. Other PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. When supported on selected control node, PCI-Express riser cards are optional with InfiniBand | |
| Redundant Power Supply | Offered for HP ProLiant DL585 G5. Not available with HP ProLiant DL165 G5. | |
| Utility Node | Select Node Configuration per Pool and Number of Nodes | HP ProLiant DL385 G5p server
NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/10480.html |
| Choose Processor Option | All currently shipping processors for HP ProLiant DL385 G5p Servers are available. Select one or two processors. | |
| Memory Options | HP ProLiant DL385 G5p is available with up to 64GB PC2-5300 or 32GB PC2-6400 memory per processor. | |
| DVD Drive Options | DVD is optional. | |
| Disk Options | HP ProLiant DL385 G5p Server available with up to eight SAS or SATA drives, or up to six SATA or SAS Large Form Factor drives. | |
| PCI - I/O Options | When non Gigabit Ethernet interconnect selected, compute nodes are configured with supported adapter (PCI-Express card for InfiniBand solutions). PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. | |
| Redundant Power Supply | Optional | |
| Visualization Node | Select Node Configuration per Pool and Number of Nodes | HP
xw9400 Workstation NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/12594_div/ 12594_div.html |
| Choose Processor Option | All currently shipping processors for the HP xw9400 node are available. Select one or two processors | |
| Memory Options | HP xw9400 are available with up to 64 GB DDR memory. | |
| DVD Drive Options | Required | |
| Disk Options | One disk minimum. Available with up to 4 SAS drives or 5 SATA drives. | |
| PCI - I/O Options | Based on interconnect selected, visualization nodes are configured with supported adapter. PCI options include an additional Gigabit Ethernet interface. | |
| Graphics | Supported PCI-Express 16X graphics adapters are NVIDIA FX3500, FX4600 and FX5500, up to 2 per node. NVIDIA G-sync card is an available option with the FX5500 adapter. | |
| Redundant Power Supply | Not available. | |
| | ||
| HP Cluster Platforms 4000BL | ||
| Control Node (HP Cluster Platform 4000BL) | Select One Server |
HP ProLiant DL385 G5p Server (recommended for PCI slot availability) |
| Choose Processor Option |
All currently shipping processors for each control node are available. Select one or two processors. | |
| Memory Options | HP ProLiant DL165 G5, HP ProLiant DL385 G5p, HP ProLiant BL465c G5 are available with PC2-5300 or PC2-6400 memory. Maximum memory will vary by server. | |
| DVD Drive Options | DVD is required option for ProLiant DL control nodes. If the control node is a ProLiant BL465c G5, there is no DVD drive option available. The control node is intended to be used with the virtual media feature included in the Integrated Lights-Out 2 Standard Blade Edition (comes with the server blade). | |
| Disk Options | One disk minimum for control nodes. HP ProLiant DL385 G5p Server available with up to eight SATA or SAS Small Form Factor drives, or up to six SATA or SAS Large Form Factor drives. HP ProLiant DL165 G5 available with up to four NHP SATA, HP SATA or HP SAS drives. HP ProLiant BL465c G5 available with up to two HP SATA or HP SAS Small Form Factor drives. | |
| PCI - I/O Options | Control nodes feature option to connect to the high-performance cluster interconnect. Other PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. When InfiniBand interconnect selected and control node connection to the interconnect selected, control node is configured with PCI-Express or Mezzanine card supported adapter. | |
| Redundant Power Supply | Recommended for control nodes when available | |
|
| ||
| Compute Node | Specify Node per Pool and Number of Nodes |
HP ProLiant BL465c G5 |
| Choose Processor Option |
All currently shipping processors for each compute node are available. Select one or two processors. | |
| Memory Options | HP ProLiant BL465c G5 is available with PC2-6400 memory. Maximum memory is 16GB per processor. | |
| DVD Drive Options | Not offered | |
| Disk Options |
HP ProLiant BL465c G5 available with up to two HP SATA or HP SAS Small Form Factor drives. | |
| PCI - I/O Options | When InfiniBand interconnect selected, compute nodes are configured with mezzanine supported adapter. Other PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. | |
| Redundant Power Supply | Not applicable | |
| Utility Node | Select
Node Configuration per Pool and Number of Nodes |
HP ProLiant DL385 G5p server HP ProLiant DL585 G5 server HP ProLiant BL465c G5 NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/12534.html |
| Choose Processor Option | All currently shipping processors for each utility node are available. Select one or two processors (two or four processors with DL585 G5). | |
| Memory
Options |
HP ProLiant DL385 G5p, HP ProLiant DL585 G5 and HP ProLiant BL465c G5 are available with PC2-5300 or PC2-6400 memory. Maximum memory will vary by server. | |
| DVD Drive Options | DVD is optional. | |
| Disk Options | One disk minimum for utility nodes. HP ProLiant DL385 G5p Server available with up to eight SATA or SAS small form factor drives, or up to six SATA or SAS Large Form Factor drives. HP ProLiant DL585 G5 Server available with up to eight SATA or SAS small form factor drives. HP ProLiant BL465c G5 available with up to two HP SATA or HP SAS Small Form Factor drives. | |
| PCI - I/O Options | When InfiniBand interconnect selected, compute nodes are configured with mezzanine supported adapter. PCI options include Fibre Channel HBA, and additional Gigabit Ethernet interface. | |
| Redundant Power Supply | Optional |
|
|
Standard Features (HP Cluster Platform 3000 and 4000: Dense and Modular packaging)
| High Speed Interconnects (up to one interconnect fabric per Cluster Platform) | |
| InfiniBand DDR and QDR |
Numerous InfiniBand implementations are supported and can be selected
based on the bandwidth requirements of the cluster. Typical clusters use
half bandwidth since this satisfies the bandwidth requirements of most
clusters. Some clusters select the higher full bandwidth. Half Bandwidth
(2:1) topology relies on twelve uplinks for every twenty four node connections
while the Full Bandwidth (1:1) utilizes eighteen uplinks for every eighteen
node connections, avoiding bottlenecks.
Four switch sizes are offered for InfiniBand DDR cluster interconnect.
|
| | |
| Gigabit Ethernet |
The HP ProCurve 2824 switch is only used as a standalone switch for small configurations up to 20 nodes (non-blocking). The HP ProCurve 3500-24G switch can be used as a standalone switch for small configurations up to 24 nodes (non-blocking). The HP ProCurve 2848 switch can be used as a standalone switch for configurations up to 40 nodes (non-blocking up to 40 ports), in pair (one) for configurations up to 64 nodes (8 links between switches), or as root switch or node level switch in tree topologies (8 uplinks/32 node ports or 4 uplinks/40 node ports). The HP ProCurve 3500-48G switch can be used as a standalone switch for small configurations up to 48 nodes (non-blocking). The HP ProCurve 5406zl switch can be used as a standalone switch for configurations up to 144 nodes (six 24-port 1000T modules) or as root switch with 4-port 10GigE modules in tree topologies for configurations up to 512 nodes (11 node level HP ProCurve 3500-48G switches attached by 2 10GigE uplinks each). The HP ProCurve 5412zl switch can be used as a standalone switch for configurations up to 288 nodes or combined with another one for configurations up to 512 nodes (one 4-port 10GigE module in each switch to aggregate switches). |
|
|
|
| Administrative and Console Network | |
|
The HP ProCurve Switch 2610-24, 2610-48, 2848 and 2824 are used to build
the internal administrative and console networks for the HP Cluster Platforms.
These two networks are independent and organized in a tree topology with
root switches and branch switches. The two root switches can be connected
together based upon software or the end-user's requirements. |
|
| HP ProCurve 2610-48 |
|
| HP ProCurve 2610-24 |
|
| HP ProCurve 2848 |
|
| HP ProCurve 2824 |
|
| HP GbE2c Ethernet Blade Switch for c-Class BladeSystem |
|
|
|
|
| Rack Infrastructure | |
| Keyboard
and Monitor | A rackmount keyboard/monitor (RKM) is required with the HP Cluster Platforms. This 1U RKM with TFT display is attached to the control node that is designated as the cluster system administration node. The TFT display is mounted in the utility rack (UBB) and provides local user access to the cluster. In systems with utility nodes, an 8-port KVM switch is also available to connect the RKM to multiple utility nodes (up to 7) to allow for failover connectivity to other nodes. Systems with visualization nodes are also equipped with a KVM and necessary expander modules so all visualization nodes are connected to the RKM. |
| Racks |
Rack 10000 series Cabinets |
| Power | HP Cluster Platform CBB, UBB, and UXR cabinets are equipped with three or four power distribution units while the IBB cabinet is equipped with two. These 1U units are installed front to back. They are all high voltage (200-240 VAC) models for all countries, equipped with appropriate power plugs:
HP Cluster Platform 3000BL and
4000BL CBB are equipped with up to eight power distribution units. These 1U units
are installed front to back. They are all high voltage (200-240 VAC) models for
all countries, equipped with appropriate power plugs:
HP Cluster
Platform VBB cabinets are equipped with one dual power monitoring power distribution
unit that mounts on the cabinet rail. These PDUs are high voltage (200-240 VAC)
models for all countries, equipped with appropriate power plugs:
|
| Documentation |
HP Cluster Platform systems include one hardware documentation kit. Each hardware
documentation kit contains both a CD and a hard copy of:
The CD contains a soft copy of the same guides and Installation and User Guides of the various components integrated in the HP Cluster Platform system. |
|
| |
| Storage | |
| MSA2000 |
|
| MSA60 |
|
|
|
|
| Software | ||
| OS
Support |
Linux | |
|
||
|
HPC 8 pack ordering information
|
||
| Windows | ||
| Microsoft Windows HPC Server 2008 | ||
|
| ||
| Cluster Management | HP CMU | |
|
The HP Cluster Management Utility is designed to manage a large number of compute nodes with a Single System View GUI (Graphics User Interface). HP CMU comes with a full Java GUI that can be tailored for your needs and for any number of nodes in the cluster. HP CMU is HP SIM (System Integration Manager) level 1 integration compliant. HP CMU provides a Command Line Interface (CLI) for day-to-day administration and cloning. Through its user friendly graphical interface HP CMU provides the cluster administrator with three main features:
NOTE: Complete information on HP CMU software, including QuickSpecs, can be found at the following URL: www.hp.com/go/cmu |
||
| Platform HPC for Insight Control Environment for Linux (ICE-LX) | ||
|
Platform HPC enables easy and rapid deployment and administration of
an HPC cluster with choice of popular open source components, fully supported
by HP and Platform Computing. The combination of Platform HPC and ICE-LX
builds on the market-proven ProLiant system management technology developed
by HP for scalable monitoring and provisioning of its servers, and adds
features and options required to deploy a fully functional HPC cluster,
including resource management, MPI and interconnect network drivers. Platform
HPC includes the packages and kitting capability utilized by Platform
in its Open Cluster Stack (OCS) product. |
||
| HP-MPI | ||
| A high-performance implementation of the Message-Passing Interface (MPI) Standard that provides developers of technical applications with an API and software library to support parallel, message-passing applications that are efficient, portable and flexible. HP-MPI complies with the MPI-1.2 and MPI-2 standards and is a high performance, robust, high quality, native implementation. HP-MPI enhancements provide optimized point-to-point and collective communication routines. (Note: HP-MPI is also included with XC Software, so no separate purchase requirement if XC selected) | ||
|
|
||
| Service and Support |
HP Cluster Platform solutions warranties and service options are based on the offerings of the underlying components. HP customer support provides onsite
hardware break/fix support and remote, remedial software call-center support.
Customer support offsite software services include level 1 and 2 support:
The HP software support team will work in parallel with the appropriate vendor and development groups to address level 3 and 4 support elevations:
HP
has experience servicing systems, networks, storage devices, and software for
HPC deployments and environments of all sizes. A wide range of purchasing options
and solutions built from standards-based service modules ensure the service coverage
and the level of expert assistance desired. Optional services may be purchased at the time of the product purchase as HP Care Pack services, easy to order and easy to use service packages. Optional services may also be purchased at a later point of time as HP Contractual or Per-Event Services to extend and/or expand and/or complement the standard product warranty. Hardware Support:
Service capabilities include total lifecycle support, preventive and diagnostic
services, access to a global service network, and support for an array of third-party
peripherals. Hardware Support Services offer a full range of high-quality remote and onsite hardware support options to meet specific response or repair-time objectives. These support options range from next-day or 4-hour onsite response to 6-hour call-to-repair time commitments. To accommodate specific hours of operations, coverage window options range from standard business hours (9x5), Monday-Friday 8am-5pm local time up to 24x7. Software Support: Standard software support includes 9x5 telephone support and rights to new versions for the specified period of time (one year or three years). 24x7 software support extends the telephone support window to round-the-clock access. Standard software support includes customer access to technical resources during standard hours (see later), problem analysis, escalation management, and resolution. HP also provides unlimited access to an electronic facility that includes a knowledge database with known symptoms and solutions, software product descriptions, specifications, and technical literature. Software support contracts can be obtained to meet the needs of customers, including remedial technical remote support along with migration and upgrade planning and a full suite of proactive deliverables. | |
| NOTE:
For more complete information on HP Services offerings, customers and resellers,
please visit us at: http://www.hp.com/hps
NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html | ||
|
|
Configuration Information - Factory Integration
| IMPORTANT: The HP Cluster Platforms are customized by HP and resellers using the Configure-To-Order process to receive a complete factory integrated cluster with options delivered in a single package. The Purchase Order must list each part number individually. The steps below describe the Factory Integration services provided during assembly and delivery of HP Cluster Platforms. | |
|
Step 1: Determine Hardware Factory Integration services | |
| Factory Integration for HP
Cluster Platforms. Factory integration of all hardware components conforming to HP Cluster Platform configuration rules. This includes all cables routing and test of these components at hardware level. Factory integration requires hardware installation services, per solution, per cabinet and per node (if no software load required). An additional charge per node is required if software installation is selected (Step 2). | |
| A Base Hardware Integration service is required per cabinet. Select one Custom Placement and one Rack Signal Cable Interconnect services for every cabinet in the solution. | |
| HP Custom Placement within Rack Service |
HA864A1 |
| HP Rack Signal Cable Interconnect Svc |
HA865A1 |
| A Base Hardware Integration service is required per solution. Select one Modular or High Density base hardware integration | |
| Base Hardware Integration - Cluster Platforms - Modular (Min 0/Max 1) |
AC067A |
| Base Hardware Integration - Cluster Platforms - High Density (Min 0/Max 1) |
AC068A |
| If factory installation of software is not required, order one Node Hardware Integration Service for every Compute and Utility node in the solution |
AC069A |
| | |
|
Step 2: Determine Software Factory Installation Services | |
| HPTC Cluster Platform Software Installation Service - predetermined schedule of charges based on total node count. If factory software installation is required, order appropriate service based on total number of nodes. For more than 257 nodes, contact HP for a quotation. These services replace the AC069A node hardware integration service from Step 1 above. | |
| HP Cluster Platform Factory Software Service (4-8 nodes) |
HB480A1 |
| HP Cluster Platform Factory Software Service (9-17 nodes) |
HB481A1 |
| HP Cluster Platform Factory Software Service (18-33 nodes) |
HB482A1 |
| HP Cluster Platform Factory Software Service (34-65 nodes) |
HB483A1 |
| HP Cluster Platform Factory Software Service (66-129 nodes) |
HB484A1 |
| HP Cluster Platform Factory Software Service (130-257 nodes) |
HB485A1 |
| For a solution containing visualization nodes, Custom Integration Services must be ordered in addition to the above Factory Software Service. | |
| HP Factory Express Standard ISS Custom SVC | HF481A1 |
| HP Factory Express Complex ISS Custom SVC | HF482A1 |
| | |
|
Step 3: Add on-site Field Installation | |
| Field installation of the cluster, ie unpacking, assembling, cabling, power up and quick check (if software is factory loaded) - Highly recommended. The following part numbers cover both, factory integration and on-site installation services. Therefore the Factory Express part numbers listed in Step 1 (HA864A1 and HA865A1) are not necessary when these Step 3 part numbers are ordered. AC067A, AC068A and AC069A part numbers listed at Step 1 remain necessary for Cluster Platform integration and test. Part numbers listed at Step 2 also remain necessary for Software installation. | |
| A Factory Express Level 3 Integration Service is required on a per rack basis |
HA453A1-000 |
| A Factory Express Level 3 Integration Service is required on a per component basis: | |
| For 1U, 2U and 4U nodes (DL160 G5, DL165 G5, DL380 G5, DL385 G5, DL585 G5) | HA453A1-001 |
| For c-Class enclosures. One per enclosure. | HA453A1-003 |
| For storage and networking, MSA60, modular switches | HA453A1-021 |
| For storage, MSA1500 based | HA453A1-022 |
| | |
| Consulting and Integration Services |
C& I options include on-site systems software support and applications development and optimization, as well as clusters training. This is in addition to options for Factory and Field On-site installation (see above). Based on compute node counts. | |
| Start Up Services - On-site Introduction to Cluster Platform 3000/4000 Recommended for each cluster deployment. Required for platforms with HP installed cluster software (e.g., XC System Software). | ||
| up to 16 nodes - HPC Clusters-one day on-site systems software knowledge transfer and five hours of customer integration management |
U5628A#001 | |
| up to 32 nodes - HPC Clusters-two days on-site systems software knowledge transfer and six hours of customer integration management |
U5628A#002 | |
| up to 64 nodes - HPC Clusters-three days on-site systems software knowledge transfer and six hours of customer integration management |
U5628A#003 | |
| up to 128 nodes - HPC Clusters-five days on-site systems software knowledge transfer and six hours of customer integration management |
U5628A#004 | |
| up to 256 nodes - HPC Clusters-ten days on-site systems software knowledge transfer and twelve hours of customer integration management |
U5628A#005 | |
| Greater than 256 nodes: Custom quote | ||
| Recommended Services - (For clusters up to 32 nodes) | ||
| HPC Cluster Implementation Program Management - 40 hours implementation management consulting |
U5617A | |
| HPC Cluster systems software QuickStart - 5 days on site consulting and six hours management coordination | U5618A | |
| HPC Cluster Applications Migration, Development, and Optimization QuickStart - 5 days on site consulting six hours mgt coordination | U5619A | |
| HPC Applications Programming and Migration - 2 days on-site formal customer training |
U5626A | |
| HPC Cluster Systems Administration Course - 4 days on-site formal customer training |
U5627A | |
| Recommended Services - (For clusters from 33 nodes up to 128 nodes) | ||
| HPC Implementation Program Management - 80 hours implementation management consulting |
U5620A | |
| HPC Cluster Systems QuickStart - 10 days on site consulting and twelve hours management coordination | U5621A | |
| HPC Cluster Applications Migration, Development, and Optimization QuickStart - 10 days on site consulting and 20H mgt coordination | U5622A | |
| HPC Applications Programming and Migration - 2 days on-site formal customer training |
U5626A | |
| HPC Cluster Systems Administration Course - 4 days on-site formal customer training |
U5627A | |
| Recommended Services - (For clusters from 129 nodes up to 256 nodes) | ||
| HPC Implementation Program Management - 120 hours implementation management consulting |
U5623A | |
| HPC Cluster Systems QuickStart - 15 days on site consulting and sixteen hours management coordination | U5624A | |
| HPC Cluster Applications Migration, Development, and Optimization QuickStart - 15 days on site consulting and 16H mgt coordination | U5625A | |
| HPC Applications Programming and Migration - 2 days on-site formal customer training |
U5626A | |
| HPC Cluster Systems Administration Course - 4 days on-site formal customer training |
U5627A | |
| Recommended Services - For clusters above 256 nodes, customized service plan is recommended | ||
|
|
Related Options
|
Software |
||
| OS Support | Linux | |
| HPC RHEL 8-pack 2P 1Yr License |
443934-B21
|
|
| HPC RHEL 8-pack 2P 3Yr License |
443935-B21
|
|
| HPC RHEL Single Node 2P 1Yr License |
443938-B21
|
|
| HPC RHEL Single Node 2P 3Yr License |
443939-B21
|
|
| HPC RHEL 8-pack 4P 1Yr License |
443936-B21
|
|
| HPC RHEL 8-pack 4P 3Yr License |
443937-B21
|
|
| HPC RHEL Single Node 4P 1Yr License |
443940-B21
|
|
| HPC RHEL Single Node 4P 3Yr License |
443941-B21
|
|
| Novell Suse SLES x64 1Yr Base 8Pk Lic |
431123-B21
|
|
| Novell Suse SLES x64 1Yr Addon 8Pk Lic |
431127-B21
|
|
| Novell Suse SLES x64 3Yr Base 8Pk Lic |
431128-B21
|
|
| Novell Suse SLES x64 3Yr Addon 8Pk Lic |
431129-B21
|
|
| Microsoft Windows Compute Cluster Server 2003 | ||
| MS W2008 HPC Svr Npi FIO Eng SW |
504103-B21
|
|
| NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html | ||
|
|
||
| Cluster Management | HP CMU | |
| HP CMU License and Media |
433257-B21
|
|
| HP CMU Compute Node License |
433258-B21
|
|
| HP-MPI | ||
| HP-MPI for Linux Media Kit |
433039-B21
|
|
| HP MPI for Linux 4 Cores LTU |
433028-B21
|
|
| HP MPI for Linux 32 Cores LTU |
433031-B21
|
|
| HP MPI for Linux 256 Cores LTU |
433034-B21
|
|
| NOTE: HP MPI is also included with XC Software, so no separate purchase requirement if XC selected. | ||
| HP-MPI for Windows Media Kit |
433051-B21
|
|
| HP MPI for Windows 4 Cores LTU |
433040-B21
|
|
| HP MPI for Windows 16 Cores LTU |
433042-B21
|
|
| HP MPI for Windows 128 Cores LTU |
433045-B21
|
|
|
|
||
| Service and
Support Offerings (HP Care Pack Services) |
Red Hat Software Operating Environment Software Telephone, 1 Year 9x5 - 10 incident (Electronic) |
U3402E
|
| Red Hat IA32,Software Technical Support, 1 Year 7x24 - 10 incident (Electronic) |
U3406E
|
|
| SuSE IA, Software Technical Support, 1 Year 7x24 - 10 incident (Electronic) |
U9935E
|
|
| SuSE IA, Software Technical Support, 1 Year 9x5 10 incident (Electronic) |
U9936E
|
|
| SuSE IA, Software Technical Support, 1 Year 7x24 - 10 incident (Electronic) |
U9935E
|
|
| SuSE IA, Software Technical Support, 1 Year 9x5 10 incident (Electronic) |
U9936E
|
|
| HP 1 Year 9x5 10 incident MS/Novell Software Technical Support (per Windows cluster) |
U9268E
|
|
| HP 1 Year 24x7 10 incident MS/Novell Software Technical Support (per Windows cluster) |
U9269E
|
|
| Windows 1 Year 9x5 Unlimited Software technical Support (per node) |
UF105E
|
|
| Windows 1 Year 24x7 Unlimited Software technical Support (per node) |
UF106E
|
|
| Windows 3 Year 9x5 Unlimited Software technical Support (per node) |
UF107E
|
|
| Windows 3 Year 24x7 Unlimited Software technical Support (per node) |
UF108E
|
|
| HP CMU one node 1 Year 9x5 STS & Updates - unlimited |
UE871E
|
|
| HP CMU one node 1 Year 24x7 STS & Updates - unlimited |
UF086E
|
|
| HP CMU one node 3 Year r 9x5 STS & Updates - unlimited |
UF087E
|
|
| HP CMU one node 3 Year 24x7 STS & Updates - unlimited |
UF088E
|
|
| HP MPI for Linux or Windows 4 Cores LTU 1 Year 9x5 STS & Updates - unlimited |
UF093E
|
|
| HP MPI for Linux or Windows 4 Cores LTU 1 Year 24x7 STS & Updates - unlimited |
UF094E
|
|
| HP MPI for Linux or Windows 4 Cores LTU 3 Year 9x5 STS & Updates - unlimited |
UF095E
|
|
| HP MPI for Linux or Windows 4 Cores LTU 3 Year 24x7 STS & Updates - unlimited |
UF096E
|
|
| HP MPI for Linux 32 Cores LTU 1 Year 9x5 STS & Updates - unlimited |
UF101E
|
|
| HP MPI for Linux 32 Cores LTU 1 Year 24x7 STS & Updates - unlimited |
UF102E
|
|
| HP MPI for Linux 32 Cores LTU 3 Year 9x5 STS & Updates - unlimited |
UF103E
|
|
| HP MPI for Linux 32 Cores LTU 3 Year 24x7 STS & Updates - unlimited |
UF104E
|
|
| HP MPI for Linux 256 Cores LTU 1 Year 9x5 STS & Updates - unlimited |
UF113E
|
|
| HP MPI for Linux 256 Cores LTU 1 Year 24x7 STS & Updates - unlimited |
UF114E
|
|
| HP MPI for Linux 256 Cores LTU 3 Year 9x5 STS & Updates - unlimited |
UF115E
|
|
| HP MPI for Linux 256 Cores LTU 3 Year 24x7 STS & Updates - unlimited |
UF116E
|
|
| HP MPI for Windows 16 Cores LTU 1 Year 9x5 STS & Updates - unlimited |
UF097E
|
|
| HP MPI for Windows 16 Cores LTU 1 Year 24x7 STS & Updates - unlimited |
UF098E
|
|
| HP MPI for Windows 16 Cores LTU 3 Year 9x5 STS & Updates - unlimited |
UF099E
|
|
| HP MPI for Windows 16 Cores LTU 3 Year 24x7 STS & Updates - unlimited |
UF100E
|
|
| HP MPI for Windows 128 Cores LTU 1 Year 9x5 STS & Updates - unlimited |
UF109E
|
|
| HP MPI for Windows 128 Cores LTU 1 Year 24x7 STS & Updates - unlimited |
UF110E
|
|
| HP MPI for Windows 128 Cores LTU 3 Year 9x5 STS & Updates - unlimited |
UF111E
|
|
| HP MPI for Windows 128 Cores LTU 3 Year 24x7 STS & Updates - unlimited |
UF112E
|
|
|
Technical Specifications
| The following section contains information on components used in HP Cluster Platforms from our partner suppliers, and HP Cluster Platform Building Block Racks. Please refer to product-specific QuickSpecs for information on HP products offered in the Cluster Platform. | ||
| InfiniBand high-speed interconnect | Voltaire Grid Director 403636-port InfiniBand QDR Switch | |
| Dimensions (H x W x D) |
1.69 x 16.93 x 15.7 in (4.3 x 43 x 40 cm) (1U)
|
|
| Weight (single power system) |
17 lb (7.7 kg max)
|
|
| Temperature (operating) |
32° to 113° F (0° to 45° C)
|
|
| Temperature (storage) |
-13° to 158° F (-25° to 70° C)
|
|
| Humidity |
Operating-15 to 80%, non-condensing
|
|
| Non-operating-5 to 90%, non-condensing | ||
| Voltage |
100 to 240 VAC 50/60 Hz
|
|
| Power |
216 W Maximum
|
|
| Heat dissipation |
BTU/hr. max (internal Managed model)
|
|
| Voltaire ISR 9288 288-port InfiniBand Switch | ||
| Dimensions (H x W x D) |
24.5 x 17.5 x 22.75 in
(62.2 x 44.4 x 57.8 cm)(14U) |
|
| Weight (single power system) |
110 to 187.5 lb (50 to 85 kg) max
|
|
| Temperature (operating) |
32° to 113° F (0° to 45° C)
|
|
| Humidity |
Operating-15 to 80%, non-condensing
|
|
|
Non-operating-5 to 90%, non-condensing
|
||
| Voltage |
85 to 265 VAC 50/60 Hz
|
|
| Power |
2,500 W max for full configuration
|
|
| Heat dissipation |
8,000 BTU/hr. max for full configuration
|
|
|
|
||
|
| HP Cluster Platform Compute Building Block rack: The compute building block with one 10642 rack, 38 HP ProLiant DL145 G2 nodes, two HP ProCurve switches (one 2650 and one 2848), four PDUs, and cabling (maximum configuration) | ||
| Total cabinet | Shipping | ||
| Height | 78.7 in (199.90 cm) | 86.22 in (219 cm) | |
| Depth | 39.69 in (100.82 cm) | 48 in (121.92 cm) | |
| Width | 24 in (60.96 cm) | 32 in (81.28 cm) | |
| Weight (est.) | 1500 lb (680 kg) | 1650 lb (750 kg) | |
| Power connection-4 PDUs | 220 to 240, 24 amp, 50/60 Hz (each PDU) NA/Japan | 220 to 240, 32 amp, 50/60 Hz (each PDU) Int'l | |
| Power consumption (est.) | 31,000 W (maximum) -15,000 W (typical) | N/A | |
| Heat dissipation (est.) | 90,000 BTU/hr.(maximum) | N/A | |
| Temperature range (est.) | 50° to 95° F (10° to 35° C) operating | -22° to 122° F (-30° to 50° C) non-operating | |
| Relative
humidity (est.) (non-condensing) | 20% to 80% operating | 5% to 95% non-operating | |
| | |||
|
| HP Cluster Platform Utility Building Block rack: The utility building block with one 10642 rack, one Myricom 17-slot chassis, TFT display, one HP ProCurve 2848 switch, one HP ProCurve 2650 switch, one MSA1500 storage array, one MSA30 disk shelf, five DL585 nodes, three PDUs, and cabling (maximum configuration in modular packaging up to 128 nodes). | ||
| Total cabinet | Shipping | ||
| Height | 78.7 in (199.90 cm) | 86.22 in (219 cm) | |
| Depth | 39.69 in (100.82 cm) | 48 in (121.92 cm) | |
| Width | 24 in (60.96 cm) | 32 in (81.28 cm) | |
| Weight (est.) | 1200 lb (544 kg) | 1272 lb (577 kg) | |
| Power connection-4 PDUs | NA/Japan-220
to 240, 24 amp, 50/60 Hz (each PDU) | Int-220
to 240, 32 amp, 50/60 Hz (each PDU) | |
| Power consumption (est.) | 8000 W (maximum)- 5200W (typical) | N/A | |
| Heat dissipation (est.) | 27,000 BTU/hr. | N/A | |
| Temperature range (est.) | 50° to 95° F (10° to 35° C) operating | -22° to 122° F (-30° to 50° C) non-operating | |
|
| |||
|
| HP Cluster Platform Interconnect Building Block rack: The interconnect building block with one 10642 rack, four Myricom 17-slot chassis, and two PDUs (maximum configuration). | ||
| Total cabinet | Shipping | ||
| Height | 78.7 in (199.90 cm) | 86.22 in (219 cm) | |
| Depth | 39.69 in (100.82 cm) | 48 in (121.92 cm) | |
| Width | 24 in (60.96 cm) | 32 in (81.28 cm) | |
| Weight (est.) | 700 lb (318 kg) | 772 lb (350 kg) | |
| Power connection-2 PDUs | NA/Japan-220 to 240, 24 amp 50/60 Hz (each PDU) | Int-220 to 240, 32 amp 50/60 Hz (each PDU) | |
| Power consumption (est.) | 4000 W | N/A | |
| Heat dissipation (est.) | 14,000 BTU/hr. | N/A | |
| Temperature range (est.) | 50° to 95° F (10° to 35° C) operating | -22° to 122° F (-30° to 50° C) non-operating | |
| Relative
humidity (est.) (non-condensing) | 15% to 80% operating | 5% to 95% non-operating | |
|
| |||
|
| HP Cluster Platform Utility eXpansion Rack: The utility expansion rack has one 10642 rack, nine DL585 nodes or eighteen DL385, and four PDUs (maximum) | ||
| Total cabinet | Shipping | ||
| Height | 78.7 in (199.90 cm) | 86.22 in (219 cm) | |
| Depth | 39.69 in (100.82 cm) | 48 in (121.92 cm) | |
| Width | 24 in (60.96 cm) | 32 in (81.28 cm) | |
| Weight (est.) | 1400 lb (634 kg) | 1550 lb (700 kg) | |
| Power connection-3 PDUs | 220 to 240, 24 amp 50/60 Hz (each PDU) NA/Japan | 220 to 240, 32 amp 50/60 Hz (each PDU) Int'L | |
| Power consumption (est.) | 22,000 W (maximum)- 14,000 W (typical) | N/A | |
| Heat dissipation (est.) | 74,700 BTU/hr. | N/A | |
| Temperature range (est.) | 50° to 95° F (10° to 35° C) operating | -22° to 122° F (-30° to 50° C) non-operating | |
| Relative
humidity (est.) (non-condensing) | 20% to 80% operating | 5% to 95% non-operating | |
|
| |||
|
| HP Cluster Platform Visualization Building Block Rack: The visualization building block has one 10642 rack, eight xw8200 or xw9300 nodes, and one dual power monitoring PDU (maximum) | ||
| Total cabinet | Shipping | ||
| Height | 78.7 in (199.90 cm) | 86.22 in (219 cm) | |
| Depth | 39.69 in (100.82 cm) | 48 in (121.92 cm) | |
| Width | 24 in (60.96 cm) | 32 in (81.28 cm) | |
| Weight (est.) | 700 lb (318 kg) | 772 lb (350 kg) | |
| Power connection-1 PDU with 2 cables | 220 to 240, 40 amp 50/60 Hz (2 per PDU) NA/Japan | 220 to 240, 32 amp 50/60 Hz (2 per PDU) Int'l | |
| Power consumption (est.) | 10,600 W (maximum)- 6,000 W (typical) | N/A | |
| Heat dissipation (est.) | 31,000 BTU/hr.(maximum) | N/A | |
| Temperature range (est.) | 50° to 95° F (10° to 35° C) operating | 4° to 140° F (-20° to 60° C) non-operating | |
| Relative
humidity (est.) (non-condensing) | 20% to 80% operating | 5% to 90% non-operating | |
|
| |||
| Product Description |
Dimensions
|
Weight
|
P/N
|
| RHEL WS3 1Yr Base 8 pack, Media for ProLiant (64 bit) |
.25"x9"x6"
|
8 oz
|
372724-B21
|
| RHEL WS3 1Yr Add-on 8 pack for ProLiant (64-bit) |
.25"x9"x6"
|
8 oz
|
372725-B21
|
| RHEL WS3 3Yr Base 8 pack, Media for ProLiant (64 bit) |
.25"x9"x6"
|
8 oz
|
372728-B21
|
| RHEL WS4 1Yr Base 8 pack, Media for ProLiant (64 bit) |
1.25"x8"x6"
|
1 lb
|
398384-B21
|
| RHEL WS4 1Yr Add-on 8 pack for ProLiant (64-bit) |
1.25"x8"x6"
|
1 lb
|
398385-B21
|
| RHEL WS4 3Yr Base 8 pack, Media for ProLiant (64 bit) |
1.25"x8"x6"
|
1 lb
|
398386-B21
|
| RHEL WS4 3Yr Add-on 8 pack for ProLiant (64 bit) |
1.25"x8"x6"
|
1 lb
|
398387-B21
|
| SUSE SLES9 1Yr Base 8 pack, Media (64 & 32 bit) for ProLiant (3-8 processor nodes) |
1" x9" x6"
|
1 lb
|
382355-B21
|
| SUSE SLES9 1Yr Add-on 8 pack for ProLiant (64 & 32-bit (3-8 processor nodes) |
.25"x5"x3"
|
4 oz
|
382357-B21
|
| SUSE SLES9 3Yr Base 8 pack, Media (64 & 32 bit) for ProLiant (3-8 processor nodes) |
1" x8.25" x6"
|
1 lb
|
382356-B21
|
| SUSE SLES9 3Yr Add-on 8 pack for ProLiant (64 & 32-bit) (3-8 processor nodes) |
.25"x5"x3"
|
4 oz
|
382358-B21
|
| NOTE: Please refer to the individual Control Node and/or Compute Nodes (HP ProLiant DL140 G2, HP ProLiant DL145 G2 or HP ProLiant DL585) for Technical specifications at http://h18004.www1.hp.com/products/servers/platforms/index-dl.html | |||
|
|
|||
|
© Copyright 2009 Hewlett-Packard Development Company,
L.P. Microsoft and
Windows NT are US registered trademarks of Microsoft Corporation The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |