contents
 Overview      Technical Specifications      Accessories line.gif (50 bytes)

Overview

HP ProCurve Switch 5400zl Series

 
   
 
ProCurve Switch 5406zl Intelligent Edge
ProCurve Switch 5406zl-48G Intelligent Edge
 
   
 
ProCurve Switch 5412zl Intelligent Edge ProCurve Switch 5412zl-96G Intelligent Edge

Models
HP ProCurve Switch 5406zl Intelligent Edge J8697A
HP ProCurve Switch 5412zl Intelligent Edge J8698A
HP ProCurve Switch 5406zl-48G Intelligent Edge J8699A
HP ProCurve Switch 5412zl-96G Intelligent Edge J8700A
HP ProCurve 5406zl-48G-PoE+ Switch J9447A
HP ProCurve 5412zl-96G-PoE+ Switch J9448A

Key Features
  • Core, distribution and advanced access layer
  • Layer 2- Layer 4 unified networking solution
  • Enterprise-class performance, security & mobility
  • Advanced application integration (ProCurve ONE)
  • Scalable 10/100, 10/100/1000 & 10GbE connectivity

Introduction
The HP ProCurve Switch 5400zl Series consists of the most advanced intelligent switches in the HP ProCurve Networking product line. The 5400zl series includes 6-slot and 12-slot chassis and associated zl modules and bundles. The foundation for all of these switches is a purpose-built, programmable ProVision ASIC that allows the most demanding networking features, such as Quality of Service (QoS) and security, to be implemented in a scalable yet granular fashion. With 10/100, Gigabit and 10G interfaces, integrated PoE+ on 10/100 & 10/100/1000Base-T ports, and a choice of form factors, the 5400zl switches offer excellent investment protection, flexibility, and scalability, as well as ease of deployment, operation, and maintenance.

Features and Benefits

Management

  • Remote Intelligent Mirroring: mirrors selected ingress/egress traffic based on ACL, port, MAC address, or VLAN to a local or remote 8200zl/6200yl/5400zl/3500yl switch anywhere on the network
  • RMON, XRMON, and sFlow v5: provide advanced monitoring and reporting capabilities for statistics, history, alarms, and events
  • IEEE 802.1AB Link Layer Discovery Protocol (LLDP): automated device discovery protocol for easy mapping by network management applications
  • Uni-Directional Link Detection (UDLD): monitors cable between two switches and shuts down the ports on both ends if the cable is broken turning the bi-directional link into uni-directional; this prevents network problems such as loops
  • Management simplicity: ProCurve-common networking features and CLI implementation (common across ProCurve zl and yl switches)
  • Command authorization: leverages RADIUS to link a custom list of CLI commands to individual network administrator's login; also provides an audit trail
  • Friendly port names: allow assignment of descriptive names to ports
  • Dual flash images: provides independent primary and secondary OS files for backup while upgrading
  • Multiple configuration files: multiple configuration files can be stored to the flash image

Connectivity

  • NEW IPv6:
    • IPv6 host: the switches can be managed and deployed at the edge of IPv6 networks
    • Dual stack (IPv4/IPv6): provides transition mechanism from IPv4 to IPv6; supports connectivity for both protocols
    • MLD snooping: forwards IPv6 multicast traffic to the appropriate interface; prevents IPv6 multicast traffic from flooding the network
    • IPv6 ACL/QoS: supports ACL and QoS for IPv6 network traffic
    • IPv6 ready: the switch hardware can support IPv6 routing, tunneling, and security; these features will be available when enabled via software update in follow-on releases
  • IEEE 802.3af Power over Ethernet: provides up to 15.4 W per port to IEEE 802.3af-compliant PoE powered devices such as IP phones, wireless access points, and security cameras
  • NEW IEEE 802.3at Power Over Ethernet Plus: provides up to 30 W per port to IEEE 802.3 for PoE/PoE+ powered devices such as video IP phones, IEEE 802.11n wireless access points, and advanced pan/zoom/tilt security cameras
  • Pre-standard PoE support: detects and provides power to pre-standard PoE devices; see list of supported devices in the product FAQ at: www.ProCurve.com
  • High-density port connectivity: up to 12 interface module slots and up to 288 wire-speed 10/100/1000 PoE-enabled ports or 48 10-GbE ports per system
  • Jumbo frames: on Gigabit and 10-Gb ports, allow high-performance remote backup and disaster-recovery services
  • Auto-MDIX: automatically adjusts for straight-through or crossover cables on all 10/100 and 10/100/1000 ports

Performance

  • High-speed/capacity architecture: 691.2 Gbps crossbar switching fabric provides intra- and inter-module switching with 480.3 million pps throughput on the purpose-built ProVision ASICs
  • Selectable queue configurations: increase performance by selecting the number of queues and associated memory buffering that best meet the requirements of your network applications

Resiliency and high availability

  • Virtual Router Redundancy Protocol (requires Premium License): VRRP allows groups of two routers to dynamically back each other up to create highly available routed environments
  • IEEE 802.1s Multiple Spanning Tree Protocol: provides high link availability in multiple VLAN environments by allowing multiple spanning trees; encompasses IEEE 802.1D Spanning Tree Protocol and IEEE 802.1w Rapid Spanning Tree Protocol
  • NEW Server-to-switch distributed trunking: allows a server to connect to two switches with one logical trunk that consists of multiple physical connections; enables load-balancing and increases resiliency
  • IEEE 802.3ad Link Aggregation Control Protocol (LACP) and ProCurve trunking: support up to 60 trunks, each with up to 8 links (ports) per trunk
  • Optional redundant power supply (5400zl series): provides uninterrupted power and allows hot-swapping of the redundant power supplies when installed
  • Hot-swappable modules (5400zl series): permits modules, mini-GBICs, and power supplies in a redundant power supply configuration to be added or swapped without interrupting the network
  • Sparing simplicity: ProCurve zl-common accessories (interface modules, power supplies)

Layer 2 switching

  • IEEE 802.1ad Q-in-Q (requires Premium License): increases the scalability of Ethernet network by providing a hierarchical structure; connects multiple LANs on high-speed campus or metro network
  • ProCurve switch meshing: dynamically load-balances across multiple active redundant links to increase available aggregate bandwidth
  • VLAN support and tagging: supports the IEEE 802.1Q standard and 2,048 VLANs simultaneously
  • IEEE 802.1v protocol VLANs: isolate select non-IPv4 protocols automatically into their own VLANs
  • GARP VLAN Registration Protocol: allows automatic learning and dynamic assignment of VLANs

Layer 3 services

  • UDP helper function: UDP broadcasts can be directed across router interfaces to specific IP unicast or subnet broadcast addresses and prevent server spoofing for UDP services such as DHCP
  • Loopback interface address: defines an address in RIP and OSPF that can always be reachable, improving diagnostic capability

Layer 3 routing

  • NEW Static IP routing: provides manually configured routing; includes ECMP capability
  • RIP: provides RIPv1 and RIPv2 routing
  • OSPF (requires Premium License): includes host-based ECMP to provide link redundancy/scalable bandwidth and NSSA

Security

  • Access control lists (ACLs): provide filtering based on the IP field, source/destination IP address/subnet, and source/destination TCP/UDP port number on a per-VLAN or per-port basis
  • Multiple user authentication methods:
    • IEEE 802.1X users per port: provides authentication of multiple IEEE 802.1X users per port; prevents user "piggybacking" on another user's IEEE 802.1X authentication
    • Web-based authentication: authenticates from Web browser for clients that do not support IEEE 802.1X supplicant; customized remediation can be processed on an external Web server
    • MAC-based authentication: client is authenticated with the RADIUS server based on client's MAC address
    • Concurrent IEEE 802.1X, Web, and MAC authentication schemes per port: switch port will accept up to 32 sessions of IEEE 802.1X, Web, and MAC authentications
  • Virus throttling: detects traffic patterns typical of WORM-type viruses and either throttles or entirely prevents the ability of the virus to spread across the routed VLANs or bridged interfaces, without requiring external appliances
  • DHCP protection: blocks DHCP packets from unauthorized DHCP servers, preventing denial-of-service attacks
  • Secure management access: all access methods--CLI, GUI, or MIB--are securely encrypted through SSHv2, SSL, and/or SNMPv3
  • USB Secure Autorun (requires HP ProCurve Manager Plus): deploys, diagnoses, and updates switch using USB flash drive; works with secure credential to prevent tampering
  • Switch CPU protection: provides automatic protection against malicious network traffic trying to shut down the switch
  • ICMP throttling: defeats ICMP denial-of-service attacks by enabling any switch port to automatically throttle ICMP traffic
  • Identity-driven ACL: enables implementation of a highly granular and flexible access security policy and VLAN assignment specific to each authenticated network user
  • STP BPDU port protection: blocks Bridge Protocol Data Units (BPDUs) on ports that do not require BPDUs, preventing forged BPDU attacks
  • Dynamic IP lockdown: works with DHCP protection to block traffic from unauthorized hosts, preventing IP source address spoofing
  • Dynamic ARP protection: blocks ARP broadcasts from unauthorized hosts, preventing eavesdropping or theft of network data
  • STP Root Guard: protects root bridge from malicious attack or configuration mistakes
  • Detection of malicious attacks: monitors 10 types of network traffic and sends a warning when an anomaly that potentially can be caused by malicious attacks is detected
  • Port security: allows access only to specified MAC addresses, which can be learned or specified by the administrator
  • MAC address lockout: prevents particular configured MAC addresses from connecting to the network
  • Source-port filtering: allows only specified ports to communicate with each other
  • RADIUS/TACACS+: eases switch management security administration by using a password authentication server
  • Secure Shell (SSHv2): encrypts all transmitted data for secure, remote command-line interface (CLI) access over IP networks
  • Secure Sockets Layer (SSL): encrypts all HTTP traffic, allowing secure access to the browser-based management GUI in the switch
  • Secure FTP: allows secure file transfer to and from the switch; protects against unwanted file downloads or unauthorized copying of switch configuration file
  • NEW Management Interface Wizard: CLI-based step-by-step configuration tool to help ensure that management interfaces such as SNMP, telnet, SSH, SSL, Web, and USB are secured to desired level
  • Switch management logon security: can require either RADIUS or TACACS+ authentication for secure switch CLI logon
  • Security banner: displays a customized security policy when users log in to the switch

Convergence

  • IP multicast routing (requires Premium License): includes PIM Sparse and Dense modes to route IP multicast traffic
  • IP multicast snooping (data-driven IGMP): automatically prevents flooding of IP multicast traffic
  • LLDP-MED (Media Endpoint Discovery): a standard extension of LLDP that stores values for parameters such as QoS and VLAN to automatically configure network devices such as IP phones
  • RADIUS VLAN for voice: uses standard RADIUS attribute and LLDP-MED to automatically configure VLAN for IP phones
  • PoE allocations: supports multiple methods (automatic, IEEE 802.3af class, LLDP-MED, or user specified) to allocate PoE power for more efficient energy savings

Quality of Service (QoS)

  • NEW Advanced classifier-based QoS: classifies traffic using multiple match criteria based on L2/3/4 information; applies QoS policies such as setting priority level and rate limit to selected traffic per port or per VLAN
  • Layer 4 prioritization: enables prioritization based on TCP/UDP port numbers
  • Traffic prioritization: allows real-time traffic classification into eight priority levels mapped to eight queues
  • Bandwidth shaping:
    • Port-based rate limiting: per-port ingress/egress enforced maximum bandwidth
    • Classifier-based rate limiting: uses ACL to enforce maximum bandwidth for ingress traffic on each port
    • Guaranteed minimum: per-port, per-queue egress-based guaranteed minimum bandwidth
  • Class of Service (CoS): sets the IEEE 802.1p priority tag based on IP address, IP Type of Service (ToS), L3 protocol, TCP/UDP port number, source port, and DiffServ

Warranty and support*

  • ProCurve Lifetime Warranty: for as long as you own the product, with next-business-day advance replacement (available in most countries).
  • Electronic and telephone support: limited electronic and telephone support is available from HP. Refer to the HP Web site at: www.procurve.com/support for details on the support provided and the period during which support is available.
  • Software releases: refer to the HP Web site at: www.procurve.com/support for details on the software releases provided and the period during which software releases are available.

* For as long as you own the product, with next-business-day advance replacement (available in most countries). The following hardware products have a five-year hardware warranty for the disk drive and lifetime hardware warranty (for as long as you own the product) for the rest of the module: HP ProCurve ONE Services zl Module, HP ProCurve Threat Management Services zl Module, and HP ProCurve MSM765zl Mobility Controller. The following hardware products and their related series modules have a one-year hardware warranty with extensions available: HP ProCurve Routing Switch 9300m series, HP ProCurve Switch 8100fl series, HP ProCurve Network Access Controller 800, and HP ProCurve DCM Controller. The following hardware products have a one-year hardware warranty with extensions available: HP ProCurve M111 Client Bridge, HP ProCurve MSM3xx-R Access Points, HP ProCurve MSM7xx Mobility and Access Controllers, HP ProCurve RF Manager IDS/IPS Systems, HP ProCurve MSM Power Supplies, HP ProCurve 1-Port Power Injector, HP ProCurve CNMS Appliances, and HP ProCurve MSM317 Access Device. Standalone software, upgrades, or licenses may have a different warranty duration. For details, refer to the ProCurve Software License, Warranty, and Support booklet at: www.procurve.com/warranty.

contents
 Overview      Technical Specifications      Accessories line.gif (50 bytes)

Technical Specifications

HP ProCurve Switch 5406zl Intelligent Edge (J8697A) Ports 6 open module slots
1 RS-232C DB-9 console port
  Maximum ports Supports a maximum of 144 auto-sensing 10/100/1000 ports or 24 10-GbE ports or 144 mini-GBICs, or a combination
Power supplies 2 open power supply slots  
Physical characteristics Dimensions 17.75(d) x 17.5(w) x 6.9(h) in. (45.09 x 44.45 x 17.53 cm) (4U height)
Weight 23.55 lb. (10.68 kg)
Memory and processor Gigabit Module ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM
10G module ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM
Management Module Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM
Mounting Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance Latency 1000 Mb: < 3.7 µs (FIFO 64-byte packets);
10 Gbps: < 2.1 µs (FIFO 64-byte packets)
Throughput up to 240.2 million pps
Routing/Switching capacity 322.8 Gbps
Switch fabric speed 345.6 Gbps
Routing table size 10,000 entries
Environment Operating temperature 32ºF to 131ºF (0ºC to 55ºC); 0°C to 40°C with
J8706A or J8707A modules installed
Operating relative humidity 15% to 95% @ 131ºF (55ºC), non-condensing
Non-operating/
Storage temperature
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage relative humidity
15% to 95% @ 149ºF (65ºC), non-condensing
Altitude up to 10000 ft. (3 km)
Acoustic Power: 57 dB, Pressure: 40.2 dB ISO 7779, ISO 9296
Electrical characteristics Achieved Miercom Certified Green Award*
* Products within this series have achieved sufficient scores in each of the rated criteria to achieve the Miercom Certified Green distinction Award. See the Specifications section of this series for more information.
Description Chassis ships without power supplies. Two power-supply slots available; two different power supplies available. See power-supply products for additional specifications.
Maximum heat dissipation 2450 BTU/hr (2584 kJ/hr), (max non-PoE); 3700 BTU/hr (3903 kJ/hr) (max using PoE)
Voltage 100-127 / 200-240 VAC
Frequency 50 / 60 Hz
Notes Power supplies must be ordered separately. Heat
dissipation does not include heat dissipated by the PoE powered devices themselves.
Safety CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Emissions FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity EN EN 55024, CISPR 24
ESD IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated IEC 61000-4-3; 3 V/m
EFT/Burst IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge IEC 61000-4-5; 1 kV/2 kV AC
Conducted IEC 61000-4-6; 3 V
Power frequency magnetic field IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics EN 61000-3-2, IEC 61000-3-2
Flicker EN 61000-3-3, IEC 61000-3-3
Management HP ProCurve Manager Plus; HP ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
Notes When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
Services 3-year, 4-hour onsite, 13x5 coverage for hardware (UE250E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UE251E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (UE252E)
3-year, 24x7 SW phone support, software updates (UF786E)
Installation with minimum configuration, system-based pricing (U4828E)
Installation with HP-provided configuration, system-based pricing (U4832E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR900E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR901E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR902E)
4-year, 24x7 SW phone support, software updates (UR903E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR904E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR905E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR906E)
5-year, 24x7 SW phone support, software updates (UR907E)

Refer to the HP website at: www.procurve.com/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
Standards and protocols Device Management RFC 1591 DNS (client)
HTML and telnet management
General Protocols IEEE 802.1ad Q-in-Q (Premium License)
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
IP Multicast RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode (Premium License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium License)
IPv6 RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Auto-configuration
MIBs RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
Network Management IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
SNMPv1/v2c/v3
XRMON
OSPF RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
QoS/Cos RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
Security IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting
Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell

HP ProCurve Switch 5412zl Intelligent Edge (J8698A) Ports 12 open module slots
1 RS-232C DB-9 console port
  Maximum ports Supports a maximum of 288 auto-sensing 10/100/1000 ports or 48 10-GbE ports or 288 mini-GBICs, or a combination
Power supplies 4 power supply slots
Physical characteristics Dimensions 17.75(d) x 17.5(w) x 12.1(h) in. (45.09 x 44.45 x 30.73 cm) (7U height)
Weight 34.94 lb. (15.85 kg)
Memory and processor Gigabit Module ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM
10G Module ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM
  Management Module Freescale PowerPC 8540 @ 666 MHz, 4 MB flash Mb, 128 MB compact flash, 256 MB DDR SDRAM
Mounting Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance Latency 1000 Mb: < 3.7 µs (FIFO 64-byte packets);
10 Gbps: < 2.1 µs (FIFO 64-byte packets)
Throughput up to 480.3 million pps
Routing/Switching capacity 645.6 Gbps
Switch fabric speed 691.2 Gbps
Routing table size 10,000 entries
Environment Operating temperature 32ºF to 131ºF (0ºC to 55ºC); 0°C to 40°C with
J8706A or J8707A modules installed
Operating relative humidity 15% to 95% @ 131ºF (55ºC), non-condensing
Non-operating/
Storage temperature
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage relative humidity
15% to 95% @ 149ºF (65ºC), non-condensing
Altitude up to 10000 ft. (4.6 km)
Acoustic Power: 64 dB, Pressure: 57.5 dB ISO 7779, ISO 9296
Electrical characteristics Description Chassis ships without power supplies. Four power supply slots available; two different power supplies available. See power-supply products for additional specifications.
Maximum heat dissipation 4900 BTU/hr (5169 kJ/hr), (max non-PoE); 7400 BTU/hr (7,807 kJ/hr) (max using PoE)
Voltage 100-127 / 200-240 VAC
Frequency 50 / 60 Hz
Notes Power supplies must be ordered separately. Two power supplies are required to power the J8698A chassis. Heat dissipation does not include heat dissipated by the PoE powered devices themselves.
Safety CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Emissions FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity EN EN 55024, CISPR 24
ESD IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated IEC 61000-4-3; 3 V/m
EFT/Burst IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge IEC 61000-4-5; 1 kV/2 kV AC
Conducted IEC 61000-4-6; 3 V
Power frequency magnetic field IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics EN 61000-3-2, IEC 61000-3-2
Flicker EN 61000-3-3, IEC 61000-3-3
Management HP ProCurve Manager Plus; HP ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
Notes When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
Services 3-year, 4-hour onsite, 13x5 coverage for hardware (UE253E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UE254E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (UE255E)
3-year, 24x7 SW phone support, software updates (UF788E)
Installation with minimum configuration, system-based pricing (U4828E)
Installation with HP-provided configuration, system-based pricing (U4832E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR900E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR916E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR917E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR918E)
4-year, 24x7 SW phone support, software updates (UR919E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR920E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR921E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR922E)
5-year, 24x7 SW phone support, software updates (UR923E)

Refer to the HP website at: www.procurve.com/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
Standards and protocols Device Management RFC 1591 DNS (client)
HTML and telnet management
General Protocols IEEE 802.1ad Q-in-Q (Premium License)
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
IP Multicast RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode (Premium License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium License)
IPv6 RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Auto-configuration
MIBs RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
Network Management IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
SNMPv1/v2c/v3
XRMON
OSPF RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
QoS/Cos RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
Security IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell

HP ProCurve Switch 5406zl-48G Intelligent Edge (J8699A) Included accessories 2 HP ProCurve Switch zl 24-Port 10/100/1000 PoE Module (J8702A)
1 HP ProCurve Switch zl 875W Power Supply (J8712A)
Ports 4 open module slots
48 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T); Media Type: Auto-MDIX; Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
1 RS-232C DB-9 console port
  Maximum ports Supports a maximum of 144 auto-sensing 10/100/1000 ports or 16 10-GbE ports or 96 mini-GBICs, or a combination
Power supplies includes: 1 x J8712AHP ProCurve Switch zl 875 W Power Supply
1 open power supply slots
Physical characteristics Dimensions 17.75(d) x 17.5(w) x 6.9(h) in. (45.09 x 44.45 x 17.53 cm) (4U height)
Weight 34.26 lb. (15.54 kg)
Memory and processor Gigabit Module ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM
10G Module ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM
  Management Module Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM
Mounting Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance Latency 1000 Mb: < 3.7 µs (FIFO 64-byte packets);
10 Gbps: < 2.1 µs (FIFO 64-byte packets)
Throughput up to 240.2 million pps
Routing/Switching capacity 322.8 Gbps
Switch fabric speed 345.6 Gbps
Routing table size 10,000 entries
Environment Operating temperature 32ºF to 131ºF (0ºC to 55ºC); 0°C to 40°C with
J8706A or J8707A modules installed
Operating relative humidity 15% to 95% @ 131ºF (55ºC), non-condensing
Non-operating/
Storage temperature
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage relative humidity
15% to 95% @ 149ºF (65ºC), non-condensing
Altitude up to 10000 ft. (4.6 km)
Acoustic Power: 57 dB, Pressure: 40.2 dB ISO 7779, ISO 9296
Electrical characteristics Description One J8712A installed. One open power supply slot available; two different power supplies available. See power supply products for additional specifications.
Maximum heat dissipation 2450 BTU/hr (2584 kJ/hr), (max non-PoE); 3700 BTU/hr (3903 kJ/hr) (max using PoE)
Voltage 100-127 / 200-240 VAC
Idle power 166 W
Frequency 50 / 60 Hz
Notes Idle power is the actual power consumption of the device with no ports connected.
Heat dissipation does not include heat dissipated by the PoE powered devices themselves.
Safety CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Emissions FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity EN EN 55024, CISPR 24
ESD IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated IEC 61000-4-3; 3 V/m
EFT/Burst IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge IEC 61000-4-5; 1 kV/2 kV AC
Conducted IEC 61000-4-6; 3 V
Power frequency magnetic field IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics EN 61000-3-2, IEC 61000-3-2
Flicker EN 61000-3-3, IEC 61000-3-3
Management HP ProCurve Manager Plus; HP ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
Notes When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
Services 3-year, 4-hour onsite, 13x5 coverage for hardware (UE250E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UE251E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (UE252E)
3-year, 24x7 SW phone support, software updates (UF786E)
Installation with minimum configuration, system-based pricing (U4828E)
Installation with HP-provided configuration, system-based pricing (U4832E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR901E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR902E)
4-year, 24x7 SW phone support, software updates (UR903E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR904E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR905E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR906E)
5-year, 24x7 SW phone support, software updates (UR907E)

Refer to the HP website at: www.procurve.com/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
Standards and protocols Device Management RFC 1591 DNS (client)
HTML and telnet management
General Protocols IEEE 802.1ad Q-in-Q (Premium License)
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
IP Multicast RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode (Premium License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium License)
IPv6 RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Auto-configuration
MIBs RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
Network Management IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
SNMPv1/v2c/v3
XRMON
OSPF RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
QoS/Cos RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
Security IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell

HP ProCurve Switch 5412zl-96G Intelligent Edge (J8700A) Included accessories 4 HP ProCurve Switch zl 24-Port 10/100/1000 PoE Module (J8702A)
2 HP ProCurve Switch zl 875W Power Supply (J8712A)
Ports 8 open module slots
96 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T); Media Type: Auto-MDIX; Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
1 RS-232C DB-9 console port
  Maximum ports Supports a maximum of 288 auto-sensing 10/100/1000 ports or 32 10-GbE ports or 192 mini-GBICs, or a combination
Power supplies includes: 2 x J8712AHP ProCurve Switch zl 875 W Power Supply
2 power supply slots
Physical characteristics Dimensions 17.75(d) x 17.5(w) x 12.1(h) in. (45.09 x 44.45 x 30.73 cm) (7U height)
Weight 58 lb. (26.31 kg)
Memory and processor Gigabit Module ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM
10G Module ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM
  Management Module Freescale PowerPC 8540 @ 666 MHz, 4 MB flash Mb, 128 MB compact flash, 256 MB DDR SDRAM
Mounting Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance Latency 1000 Mb: < 3.7 µs (FIFO 64-byte packets);
10 Gbps: < 2.1 µs (FIFO 64-byte packets)
Throughput up to 480.3 million pps
Routing/Switching capacity 645.6 Gbps
Switch fabric speed 691.2 Gbps
Routing table size 10,000 entries
Environment Operating temperature 32ºF to 131ºF (0ºC to 55ºC); 0°C to 40°C with
J8706A or J8707A modules installed
Operating relative humidity 15% to 95% @ 131ºF (55ºC), non-condensing
Non-operating/
Storage temperature
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage relative humidity
15% to 95% @ 149ºF (65ºC), non-condensing
Altitude up to 10000 ft. (4.6 km)
Acoustic Power: 64 dB, Pressure: 57.5 dB ISO 7779, ISO 9296
Electrical characteristics Description Two J8712A installed. Two open power supply slots available; three different power supplies available.
See power supply products for additional specifications.
Maximum heat dissipation 4900 BTU/hr (5169 kJ/hr), (max non-PoE); 7400 BTU/hr (7,807 kJ/hr) (max using PoE)
Voltage 100-127 / 200-240 VAC
Idle power 299 W
Frequency 50 / 60 Hz
Notes Idle power is the actual power consumption of the device with no ports connected.
Heat dissipation does not include heat dissipated by the PoE powered devices themselves.
Safety CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Emissions FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity EN EN 55024, CISPR 24
ESD IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated IEC 61000-4-3; 3 V/m
EFT/Burst IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge IEC 61000-4-5; 1 kV/2 kV AC
Conducted IEC 61000-4-6; 3 V
Power frequency magnetic field IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics EN 61000-3-2, IEC 61000-3-2
Flicker EN 61000-3-3, IEC 61000-3-3
Management HP ProCurve Manager Plus; HP ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
Notes When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
Services 3-year, 4-hour onsite, 13x5 coverage for hardware (UE253E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UE254E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (UE255E)
3-year, 24x7 SW phone support, software updates (UF788E)
Installation with minimum configuration, system-based pricing (U4828E)
Installation with HP-provided configuration, system-based pricing (U4832E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR916E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR917E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR918E)
4-year, 24x7 SW phone support, software updates (UR919E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR920E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR921E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR922E)
5-year, 24x7 SW phone support, software updates (UR923E)

Refer to the HP website at: www.procurve.com/services for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
Standards and protocols Device Management RFC 1591 DNS (client)
HTML and telnet management
General Protocols IEEE 802.1ad Q-in-Q (Premium License)
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
IP Multicast RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode (Premium License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium License)
IPv6 RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Auto-configuration
MIBs RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
Network Management IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
SNMPv1/v2c/v3
XRMON
OSPF RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
QoS/Cos RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
Security IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell

HP ProCurve 5406zl-48G-PoE+ Switch
(J9447A)
Included accessories 1 HP ProCurve 24-Port 10/100/1000 PoE+ zl Module (J9307A)
1 HP ProCurve 20-Port 10/100/1000 PoE+ and 4-Port Mini-GBIC zl Module (J9308A)
1 HP ProCurve 1500W PoE+ zl Power Supply (J9306A)
Ports 4 open module slots
44 RJ-45 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T); Media Type: Auto-MDIX; Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only
4 open mini-GBIC (SFP) slots
1 RS-232C DB-9 console port
  Maximum ports Supports a maximum of 144 auto-sensing 10/100/1000 ports or 16 10-GbE ports or 96 mini-GBICs, or a combination
Power supplies includes: 1 x J9306AHP ProCurve 1500W PoE+ zl Power Supply
1 power-supply slots
Physical characteristics Dimensions 17.75(d) x 17.5(w) x 6.9(h) in. (45.09 x 44.45 x
17.53 cm) (4U height)
Weight 34.9 lb. (15.83 kg)
Memory and processor Gigabit Module ARM9 @ 200 MHz; packet buffer size: 144 Mb
QDR SDRAM
10G Module ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM
  Management Module Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM
Mounting Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance Latency 1000 Mb: < 3.7 µs (FIFO 64-byte packets);
10 Gbps: < 2.1 µs (FIFO 64-byte packets)
Throughput up to 240.2 million pps
Routing/Switching capacity 322.8 Gbps
Switch fabric speed 345.6 Gbps
Routing table size 10,000 entries
Environment Operating temperature 32ºF to 131ºF (0ºC to 55ºC); 0°C to 40°C with
J8706A or J8707A modules installed
Operating relative humidity 15% to 95% @ 131ºF (55ºC), non-condensing
Non-operating/
Storage temperature
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage relative humidity
15% to 95% @ 149ºF (65ºC), non-condensing
Altitude up to 10000 ft. (4.6 km)
Acoustic Power: 57 dB, Pressure: 40.2 dB ISO 7779, ISO
9296
Electrical characteristics Description One J9306A installed. One open power supply slot available; three different power supplies available.
See power supply products for additional specifications.
Maximum heat dissipation 2450 BTU/hr (2584.75 kJ/hr), (max. non-PoE);
3700 BTU/hr (3903 kJ/hr) (max. using PoE)
Voltage 100-127 / 200-240 VAC
Idle power 215 W
Frequency 50 / 60 Hz
Notes Idle power is the actual power consumption of the device with no ports connected.
Heat dissipation does not include heat dissipated by the PoE powered devices themselves.
Safety CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Emissions FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity EN EN 55024, CISPR 24
ESD IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated IEC 61000-4-3; 3 V/m
EFT/Burst IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge IEC 61000-4-5; 1 kV/2 kV AC
Conducted IEC 61000-4-6; 3 V
Power frequency magnetic field IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics EN 61000-3-2, IEC 61000-3-2
Flicker EN 61000-3-3, IEC 61000-3-3
Management HP ProCurve Manager Plus; HP ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
Notes When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
Services 3-year, 4-hour onsite, 13x5 coverage for hardware (UE250E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UE251E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (UE252E)
3-year, 24x7 SW phone support, software updates (UF786E)
Installation with minimum configuration, system-based pricing (U4828E)
Installation with HP-provided configuration, system-based pricing (U4832E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR900E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR901E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR902E)
4-year, 24x7 SW phone support, software updates (UR903E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR904E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR905E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR906E)
5-year, 24x7 SW phone support, software updates (UR907E)

Refer to the HP website at: www.procurve.com/services for details on the
service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
Standards and protocols Device Management RFC 1591 DNS (client)
HTML and telnet management
General Protocols IEEE 802.1ad Q-in-Q (Premium License)
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
IP Multicast RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode (Premium License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium License)
IPv6 RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Auto-configuration
MIBs RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
Network Management IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
SNMPv1/v2c/v3
XRMON
OSPF RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
QoS/Cos RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
Security IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell

HP ProCurve 5412zl-96G-PoE+ Switch
(J9448A)
Included accessories 3 HP ProCurve 24-Port 10/100/1000 PoE+ zl Module (J9307A)
1 HP ProCurve 20-Port 10/100/1000 PoE+ and 4-Port Mini-GBIC zl Module (J9308A)
2 HP ProCurve 1500W PoE+ zl Power Supply (J9306A)
Ports 8 open module slots
92 RJ-45 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T); Media Type: Auto-MDIX; Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full
only
4 open mini-GBIC (SFP) slots
1 RS-232C DB-9 console port
  Maximum ports Supports a maximum of 288 auto-sensing 10/100/1000 ports or 32 10-GbE ports or 192
mini-GBICs, or a combination
Power supplies includes: 2 x J9306AHP ProCurve 1500W PoE+ zl Power Supply
2 power-supply slots
Physical characteristics Dimensions 17.75(d) x 17.5(w) x 12.1(h) in. (45.09 x 44.45 x
30.73 cm) (7U height)
Weight 58.18 lb. (26.39 kg)
Memory and processor Gigabit Module ARM9 @ 200 MHz; packet buffer size: 144 Mb
QDR SDRAM
10G Module ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM
  Management Module Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM
Mounting Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Performance Latency 1000 Mb: < 3.7 µs (FIFO 64-byte packets);
10 Gbps: < 2.1 µs (FIFO 64-byte packets)
Throughput up to 480.3 million pps
Routing/Switching capacity 645.6 Gbps
Switch fabric speed 691.2 Gbps
Routing table size 10,000 entries
Environment Operating temperature 32ºF to 131ºF (0ºC to 55ºC); 0°C to 40°C with
J8706A or J8707A modules installed
Operating relative humidity 15% to 95% @ 131ºF (55ºC), non-condensing
Non-operating/
Storage temperature
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage relative humidity
15% to 95% @ 149ºF (65ºC), non-condensing
Altitude up to 10000 ft. (4.6 km)
Acoustic Power: 57 dB, Pressure: 40.2 dB ISO 7779, ISO
9296
Electrical characteristics Description Two J9306A installed. Two open power supply slots available; three different power supplies available.
See power supply products for additional specifications.
Maximum heat dissipation 4900 BTU/hr (5169.5 kJ/hr), (max. non-PoE);
7400 BTU/hr (7807 kJ/hr) (max. using PoE)
Voltage 100-127 / 200-240 VAC
Idle power 312 W
Frequency 50 / 60 Hz
Notes Idle power is the actual power consumption of the device with no ports connected.
Heat dissipation does not include heat dissipated by the PoE powered devices themselves.
Safety CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Emissions FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Immunity EN EN 55024, CISPR 24
ESD IEC 61000-4-2; 4 kV CD, 8 kV AD
Radiated IEC 61000-4-3; 3 V/m
EFT/Burst IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge IEC 61000-4-5; 1 kV/2 kV AC
Conducted IEC 61000-4-6; 3 V
Power frequency magnetic field IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
Harmonics EN 61000-3-2, IEC 61000-3-2
Flicker EN 61000-3-3, IEC 61000-3-3
Management HP ProCurve Manager Plus; HP ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
Notes When using mini-GBICs with this product, mini-GBICs with revision "B" or later (product number ends with the letter "B" or later, e.g., J4858B, J4859C) are required.
Services 3-year, 4-hour onsite, 13x5 coverage for hardware (UE253E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UE254E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (UE255E)
3-year, 24x7 SW phone support, software updates (UF788E)
Installation with minimum configuration, system-based pricing (U4828E)
Installation with HP-provided configuration, system-based pricing (U4832E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR916E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR917E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR918E)
4-year, 24x7 SW phone support, software updates (UR919E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR920E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR921E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone (UR922E)
5-year, 24x7 SW phone support, software updates (UR923E)

Refer to the HP website at: www.procurve.com/services for details on the
service-level descriptions and product numbers. For details about services and response times in your area, please contact your local HP sales office.
Standards and protocols Device Management RFC 1591 DNS (client)
HTML and telnet management
General Protocols IEEE 802.1ad Q-in-Q (Premium License)
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
IP Multicast RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode (Premium License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium License)
IPv6 RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Auto-configuration
MIBs RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
Network Management IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
SNMPv1/v2c/v3
XRMON
OSPF RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
QoS/Cos RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
Security IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell
contents
 Overview      Technical Specifications      Accessories line.gif (50 bytes)

Accessories

HP ProCurve Switch 5400zl Series accessories

Modules  
HP ProCurve Switch zl 24-Port 10/100/1000 PoE Module J8702A
HP ProCurve Switch zl 4-Port 10-GbE CX4 Module J8708A
HP ProCurve Switch zl 20-Port 10/100/1000 + 4-Port Mini-GBIC Module J8705A
HP ProCurve Switch zl 24-Port Mini-GBIC Module J8706A
HP ProCurve Switch zl 4-Port 10-GbE X2 Module J8707A
NEW HP ProCurve 24-Port 10/100/1000 PoE+ zl Module J9307A
NEW HP ProCurve 24-Port 10/100 PoE+ zl Module J9478A
NEW HP ProCurve 20-Port 10/100/1000 PoE+ and 4-Port Mini-GBIC zl Module J9308A
NEW HP ProCurve 4-Port 10GbE SFP+ zl Module J9309A
Appliance  
HP ProCurve ONE Services zl Module J9289A
HP ProCurve Threat Management Services zl Module J9155A
HP ProCurve Threat Management Services zl Module with 1-year IDS/IPS subscription J9156A
License  
Premium License for Switch 5400 Series J8994A
NEW HP ProCurve MSM760/765 40-access point license J9371A
Power Supply  
HP ProCurve Switch zl 875 W Power Supply J8712A
HP ProCurve Switch zl 1500 W Power Supply J8713A
NEW HP ProCurve 1500W PoE+ zl Power Supply J9306A
EPS/RPS  
HP ProCurve Switch zl Power Supply Shelf J8714A
Transceivers  
HP ProCurve 10-GbE X2-SC ER Optic J8438A
HP ProCurve 10-GbE CX4 Media Converter J8439A
HP ProCurve 10-GbE X2-SC SR Optic J8436A
HP ProCurve 10-GbE X2-CX4 Transceiver J8440B
HP ProCurve 100-FX SFP-LC Transceiver J9054B
HP ProCurve 10-GbE X2-SC LR Optic J8437A
HP ProCurve 10-GbE X2-SC LRM Optic J9144A
HP ProCurve 100-BX-D SFP-LC Transceiver J9099B
HP ProCurve 100-BX-U SFP-LC Transceiver J9100B
HP ProCurve 10-GbE SFP+ SR Transceiver J9150A
HP ProCurve 10-GbE SFP+ LR Transceiver J9151A
HP ProCurve 10-GbE SFP+ LRM Transceiver J9152A
Mini-GBICs  
HP ProCurve Gigabit-LH-LC Mini-GBIC J4860C
HP ProCurve Gigabit-SX-LC Mini-GBIC J4858C
HP ProCurve Gigabit-LX-LC Mini-GBIC J4859C
HP ProCurve Gigabit 1000Base-T Mini-GBIC J8177C
HP ProCurve 1000-BX-D SFP-LC Mini-GBIC J9142B
HP ProCurve 1000-BX-U SFP-LC Mini-GBIC J9143B
Cables  
HP ProCurve 10-GbE SFP+ 1m Direct Attach Cable J9281B
HP ProCurve 10-GbE SFP+ 3m Direct Attach Cable J9283B
HP ProCurve 10-GbE SFP+ 7m Direct Attach Cable J9285B
Software  
HP ProCurve Manager 3.0 --
WLAN  
HP ProCurve Wireless Edge Services zl Module J9051A
HP ProCurve Redundant Wireless Services zl Module J9052A
NEW HP ProCurve MSM765zl Mobility Controller J9370A

© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Intel, Core, Pentium, and Xeon are trademarks of Intel Corporation in the U.S. and other countries. Microsoft, Windows, Windows NT, and Windows Vista are U.S. registered trademarks of Microsoft Corporation.

To learn more, visit: www.hp.com/go/procurve
Information is subject to change without notice


   DA-12436 10 - Version 10 - October 2, 2009