Overview
|
HP ProLiant DL385 Packaged Cluster with MSA500 G2
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| At A Glance
|
|
|
Standard Features
| Server | HP ProLiant DL385 server (Qty
2) NOTE: Complete information on the server can be found in the following QuickSpecs: http://h18004.www1.hp.com/products/servers/proliantdl385/index.html. |
|
|
|
| Processor (per server) | Dual-Core AMD Opteron™ 280 (2.4 GHz/1 MB) |
|
| |
| Cache
Memory (per server) | 1MB Level 2 cache per core (per processor) |
| | |
| Upgradeability (per server) |
Upgradeable to dual processing |
| | |
| Chipset (per server) | AMD Opteron™ 8000 Series Chipset |
|
|
|
| Memory Protection | Advanced ECC |
|
|
|
| Memory (per server) | Type | PC3200 400MHz DDR |
| Standard | 1 GB (2 x 512 MB) | |
| Maximum | 16 GB using PC3200 | |
| 32 GB using PC2700 (4 GB DIMMS) | ||
|
|
||
| Network Controller (per server) |
Embedded NC7782 PCI-X Gigabit Server Adapter |
|
|
|
| PCI-X Non Hot-Plug Riser | |||||||
| Expansion Slots (per server) | Slot Number | Bus Speed | Bus Number* | Device Number** | Hot Plug | PCI Voltage | NOTES |
| 1 | 64-bit/100MHz PCI-X | 5 | 7 | no | 3.3 Volt | Universal cards are supported | |
| 2 | 64-bit/100MHz PCI-X | 5 | 8 | no | 3.3 Volt | Universal cards are supported | |
| 3 | 64-bit/100MHz PCI-X | 6 | 9 | no | 3.3 Volt | Universal cards are supported | |
| *
Default bus assignment. Inserting cards with PCI bridges may alter the actual
bus assignment number. ** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID by bus (starting with the lowest bus). NOTE: All slots can accept universal keyed PCI cards. | |||||||
| | |||||||
| Storage
Controllers (per server) | Smart
Array 6i Controller (Ultra320) (integrated on system board) SCSI interconnect is provided by a Smart Array 642 Controller in server PCI slot |
| NOTE: For complete
list of devices supported the Smart array 6i Controller see the following: http://h18000.www1.hp.com/products/quickspecs/12030_na/12030_na.html | |
| | |
| Storage (per server) | Optical Drive | 24x IDE CD-ROM Drive (Universal Media Bay) |
| Hard Drives | None | |
|
|
||
| Maximum
Internal Storage Type (per server) | Hot Plug SCSI | 1.80TB | 6 x 300 GB Ultra320 HDD |
| | |||
| Interfaces (per server) | Serial | 1 |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard | 1 | |
| Network RJ-45 | 3 (1 for iLO) | |
| USB 1.1 Ports | 3 total: 1 front, 2 back NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html |
|
|
|
||
| Graphics (per server) | Integrated ATI Rage XL Video Controller with 8-MB SDRAM Video Memory |
|
|
|
| Form Factor (per server) | Rack 2U per server (3.5 inches) |
| | |
| Server Management Stand Alone Software Product - ProLiant Essentials | HP Systems Insight Manager | HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based environment to centrally manage servers, storage and other infrastructure devices, (both HP and non-HP) across multiple operating system platforms. | |
| ProLiant Essentials Rapid Deployment Pack | Rapid Deployment Pack (RDP) extends HP Systems Insight Manager with a complete deployment solution for HP ProLiant servers. RDP provides a central location to configure server hardware, deploy Windows, Linux and VMware ESX operating environments and install HP ProLiant Support Pack drivers using images and scripted profiles. For more information, visit: http://www.hp.com/servers/rdp. | ||
| ProLiant Essentials Performance Management Pack | Performance Management Pack (offered exclusively through the Insight Control suites) - a performance management solution that identifies and explains hardware performance bottlenecks on ProLiant servers and attached options enabling users to better utilize their valuable resources | ||
| Integrated Lights-Out Advanced Pack | Upgrades the iLO 2 processor with comprehensive remote control including Virtual KVM remote graphical console, enhanced console sharing and replay, virtual media (floppy, CD/DVD, USB key), virtual folders, and enterprise security (directory services and two-factor authentication). | ||
| NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to: http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. | |||
| | |||
| Core Infrastructure Management | SmartStart | SmartStart
is a tool that simplifies server setup, providing a rapid way to deploy reliable
and consistent server configurations. For more information, please visit the SmartStart
Web site at: http://www.hp.com/servers/smartstart.
SmartStart version supported (minimum): SmartStart 7.51. | |
| Insight Management Agents | The Insight Management Agents should be installed on all HP servers to present system instrumentation, health and configuration information into HP Systems Insight Manager and the HP System Management Homepage. The HP System Management Homepage aggregates systems data from Insight Management Agents and other HP management tools, providing a consolidated browser-based interface for managing individual servers. Insight Management Agents and The HP System Management Homepage are included on ProLiant Support Packs, and can also be installed using the server profiles provided with the ProLiant Essentials Rapid Deployment Pack. For additional information about the Management Agents and the HP System Management Homepage please visit the management Web site at: http://www.hp.com/servers/manage. | ||
| Subscriber's Choice | Subscriber's
Choice Driver and Support Alerts/Notifications is a web-based email subscription
service that provides software and driver change notifications for ProLiant products.
Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. | ||
| ProLiant Support Packs and ROMPaq, software | The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options, available through ProLiant Support Packs the ProLiant Essentials Rapid Deployment Pack, SmartStart or downloaded from software and drivers download pages website at: http://www.hp.com/go/support. | ||
| | |||
| Industry Standard Compliance | ACPI 2.0b Compliant |
| PCI-X and PCI 2.2 Compliant | |
| WOL Support | |
| Microsoft® Logo certifications | |
| USB version 1.1 | |
|
|
|
| Security | Power-on password Keyboard password Diskette drive control Diskette boot control QuickLock, Network Server Mode Serial interface control Administrator's password |
|
|
|
| Server Power Cords | Four (4) total Lowline power cords ship standard (per cluster) |
|
| |
| Power Supply (per server) |
575 Watt, CE Mark Compliant Optional Hot Plug Redundant Power Supply Capability |
| | |
| System Fans (per server) | 5 hot plug fans ship standard.
8 hot plug fans total supported internally for full redundancy per server NOTE: The additional 3 fans are available via Redundant Fan Option Kit (PN 293048-B21). |
|
|
|
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable
matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/index.html |
|
|
|
| Required Cabling | For required cabling information, refer to the HP Web site at: www.hp.com/servers/packagedclusters. |
| | |
| DL385 Packaged Cluster with MSA5000 G2 Packaging | 8U Configuration Fixture - Recyclable ABS |
| Unique cabling with positive identification (secured to storage configuration fixture) | |
| Two 6 foot SCSI cables | |
| One 6 foot Ethernet cross over cables | |
| Shock resistant pallet | |
|
|
|
| Documentation | Cluster set-up poster and configuration guide |
|
|
|
| OS Support | Microsoft Cluster
Service |
|
| Novell
Cluster Service |
| |
| HP
Service Guard Cluster Service for Linux |
| |
| SteelEye's LifeKeeper for Linux |
| |
| NOTE:
For more complete and up-to-date information on how to buy server operating systems
from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix at: http://www.hp.com/go/supportos. NOTE: Please refer to compatibility matrix http://www.hp.com/products/sharedstorage for latest compatibility information. NOTE: For more Linux OS support & certification information, please visit our the ProLiant & BladeSystem Server Linux matrix http://h18004.www1.hp.com/products/servers/linux/hpLinuxcert.html | ||
| | ||
|
Packaged Cluster Software Components
|
The Packaged Cluster utilizes a single, consistent set of utility software for storage and RAID management, setup, configuration and troubleshooting. This consistency reduces the cost of ownership by reducing the training and technical expertise necessary to install and maintain your HP server storage solution. |
Configuration
Management/Health
|
|
|
|
|
| Factory Express Portfolio for Servers and Storage | HP Factory Express offers configuration,
customization, integration and deployment services for HP servers and storage
products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches. For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express. |
| | |
| HP Enterprise Configurator |
The HP eCo-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. |
| | |
| Rack Airflow Requirements | Rack
10000 series Cabinets CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/packagedclusters. | |
| | |
| Rack Kit (Servers) | The DL385 quick deploy rail
system provides tool-free support for racks with square or round mounting
holes (including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment
range of 24" - 36". The ambidextrous cable management arm can
be mounted on either the left or right side for improved cable management.
NOTE: Cable management arm must be removed to access hot-plug power supplies when the cable management arm is mounted on the right. NOTE: The Modular Smart Array 500 tool-less rack rail included in the Packaged Cluster accommodates most round or square hole rack standard. |
|
|
|
| Service and Support |
HP Care Pack services provide total care and support expertise with committed response designed to meet your IT and business needs. HP Care Pack services include coverage for the HP branded hardware options qualified for the server and purchased at the same time or afterward that are internal to the enclosure. This also includes the 22" and smaller external monitors and tower UPS options up to 3kVA. These items will be covered at the same service level and for the same coverage period as the server. Coverage of UPS Battery is not included, and standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack. To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions, provides a range of support services designed to meet the varying needs of your business. Whether an SMB, or large global corporation, HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime. Recommended Service - simplify ProLiant solution implementation, maintenance, and management.
Enhanced Service - optimize service level to increase IT performance and availability.
Refer to the information on "Installation & Start-Up" for service on ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet; to be delivered on a scheduled basis 8am-5pm, M-F, excluding HP holidays. NOTE: For a complete listing of service
offerings and information visit: |
|
|
|
| Storage | Modular
Smart Array 500 G2 (Qty 1) NOTE: Complete information on the storage can be found in the following QuickSpecs: http://h18004.www1.hp.com/storage/disk_storage/msa_diskarrays/san_arrays/index.html. |
| | |
| MSA500 G2 Storage Controller | Modular Smart Array 500 G2 Controller, redundant controller capable |
|
|
|
| MSA500 G2 Storage | Drive bays | 14 Hot pluggable |
| Hard Drives | None | |
| Maximum Internal Storage | 4.20TB (14 x 300GB Ultra320 HDD) | |
| SCSI Hard Drive | Pre-failure warranty | |
| | ||
| MSA500 G2 Storage Standard Contents | 4U Modular Smart Array 500 G2 Modular Smart Array 500 G2 controller with 256 MB cache 2-port SCSI I/O module Redundant hot pluggable power supply/fans Modular Smart Array 500 rack mounting kit Power cables, 2 VHDCI SCSI cables (2) 6' each Ethernet Crossover cable for clustering |
|
|
|
| MSA500 G2 Storage Controller | Modular Smart Array 500 G2 Controller
U320 SCSI technology, redundant controller capable 4 SCSI Channels (2 Host; 2 INTL) |
|
|
|
| MSA500 G2 Host Bus Adapters | Integrated Ultra320 Smart Array
6i Plus Controller on the servers Smart Array 642 Controller (optional) |
|
|
|
| MSA500 G2 Cache Memory | 256 MB Read/Write Cache | Up to 512 MB Read/Write Cache (optional) |
| ECC protection, battery backed, removable | NOTE: Optional storage memory allows the following configurations: 1 x 256 MB or 2 x 256 MB. | |
| NOTE: When redundant controllers are installed, the cache configurations in both controllers must be identical. | ||
| | ||
| MSA500 G2 Cache Batteries | Up to three days of redundant battery life, removed for easy replacement |
|
|
|
| MSA500 G2 Upgradeable Firmware | 2 MB flashable ROM |
|
|
|
| MSA500 G2 Power Supply | 600 Watt (Dual) Power Supply,
CE Mark Compliant Fans integrated into each power supply, Redundant Functionality (Standard) |
|
|
|
| MSA500 G2 Disk Drive and Enclosure Protocol Support | Ultra320, Ultra3 and Ultra 2 SCSI Universal drives |
|
| |
| DtS (DAS to SAN) Technology | The Smart Array architecture provides a quick and easy way to migrate from the Modular Smart Array 500 G2 to the Modular Smart Array 1000 (MSA1000) for additional scalability. In
order to convert the Modular Smart Array 500 G2 to a SAN, simply remove the Modular
Smart Array Controller(s) and replace them with StorageWorks MSA1000 Controller(s)
and add FC I/O board or FC Switch (please refer to MSA 1000 QuickSpecs for additional
SAN requirements information). This is referred to as DtS technology (DAS-to-SAN
technology). |
|
| |
| MSA500 G2 Form Factor | Rack 4U |
|
|
|
| MSA500 G2 Connector Type | Ultra320 SCSI |
|
|
|
| MSA500 G2 Ports | 2 VHDCI; Ultra320 SCSI |
|
|
|
| MSA500 G2 Bandwidth | 320 MB/s |
|
|
|
| MSA500 G2 Protocols Supported | Ultra320 SCSI (320 MB/s per channel) |
| | |
| MSA500 G2 User Interface | Controller display with Status Indicators (2) and Push Buttons (4) Status indicators on front of controller (16) |
|
|
|
| MSA500 G2 SCSI Ports | 2 external VHDCI connectors standard. Optional 4-port Shared Storage Module with 4 VHDCI connectors and multi-path software included. |
|
|
|
| MSA500 G2 Logical Drives | Up to 32 logical drives |
|
|
|
| MSA500 G2 RAID Support | Raid ADG (Advanced Data Guarding) Raid 5 (Distributed Data Guarding) Raid 1+0 (Striping and Mirroring) Raid 1 (Mirroring) Raid 0 (Striping) |
|
|
Models
|
DL385 Packaged Cluster 2.4 GHz with MSA500 G2 | Processor(s) | (1) Dual-Core AMD Opteron™ 280 (2.4 GHz/1MB) Processor standard |
| Cache Memory | 1MB Integrated Level 2 Cache per core | |
| Memory | 1 GB (Standard per server) to 12 GB (Maximum) of 2 way interleaved capable PC3200 DDR SDRAM running at 400MHz, with Advanced ECC capabilities | |
| Network Controller | NC7782 Dual Port PCI-X 1000T Gigabit Server Adapter (embedded) | |
| Storage Controller | Server:
Smart Array 6i Controller (U320, integrated on system board) Storage: Smart Array 642 in server PCI SCSI connected to MSA500G2 Storage Controller | |
| Hard Drives | None ship standard | |
| Internal Storage | 1.80TB max (with optional hard drives) | |
| Optical Drive | 24x IDE CD-ROM Drive | |
| Modular Smart Array 500 G2 | 1 Modular Smart Array 500 G2 with 14 drive bays. Includes one Smart Array Storage Controller, redundant optional | |
| Form Factor | 8U configuration fixture |
|
|
Options
| Processor | Dual-Core AMD Opteron™ 280 (2.4 GHz, 1MB) Processor Option Kit |
399692-B21 |
| | ||
| Fans | DL380 G4 Redundant Fan Option Kit | 293048-B21 |
| NOTE: Hot Plug
Redundant Fan Option Kit (PN 293048-B21) contains three fans. NOTE: The Redundant Fan Option Kit (PN 293048-B21) is required to be installed when the 8 GB PC2700 DDR SDRAM DIMM Memory Kit (2 x 4 GB) (PN 395409-B21) is used. | ||
| | ||
| Memory
(SDRAM DIMMs) | 1 GB PC3200 DDR SDRAM DIMM Memory Kit (2 x 512 MB) |
376638-B21 |
| 2 GB PC3200 DDR SDRAM DIMM Memory Kit (2 x 1 GB) |
376639-B21 | |
| 4 GB PC3200 DDR SDRAM DIMM Memory Kit (2 x 2 GB) |
379300-B21 | |
| 8
GB PC2700 DDR SDRAM DIMM Memory Kit (2 x 4 GB) NOTE: The Redundant Fan Option Kit (PN 293048-B21) is required to be installed when the 8 GB PC2700 DDR SDRAM DIMM Memory Kit (2 x 4 GB) (PN 395409-B21) is used. |
395409-B21 | |
|
| ||
|
Storage Rail Kit | Round
hole rack cabinet rail kit NOTE: Supports for racks with round mounting holes (including HP rack systems/E and HP systems), with an adjustment range of 24"- 36". NOTE: The standard storage rails already support most square and round hole racks. |
293052-B21 |
|
| ||
| Riser Cards | PCI-X Hot Plug Riser Cage Option Kit |
354676-B21
|
|
| PCI-Express Riser Cage Option Kit |
354675-B21
|
||
|
|
|||
| Server Management Stand Alone Software Product - ProLiant Essentials | NOTE: Electronic licensing options are available for select ProLiant Essentials software products. Please see the appropriate ProLiant Essentials QuickSpecs for additional information. | |
| Deploy | ||
| ProLiant Essentials Rapid Deployment Pack | ||
| ProLiant Essentials Rapid Deployment Pack
No Media 1-Server License including 1 year of 24x7 Technical Support and Updates NOTE: This license allows 1 server to be deployed and managed via RDP. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_na/11053_na.html | 452151-B21 | |
| NOTE:
For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12855_na/12855_na.html | ||
| Control | ||
| Integrated Lights-Out Select Pack | ||
| ProLiant Essentials Integrated Lights-Out
Select Pack, No Media, 1-Server License NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_na/12362_na.html | 452158-B21 | |
| Integrated Lights-Out Advanced Pack | ||
| Integrated Lights-Out Advanced Pack, No
Media ,1 Server License NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/10861_na/10861_na.html | 452141-B21 | |
| Optimize | ||
| ProLiant Essentials Virtual Machine Management Pack | ||
| ProLiant Essentials Virtual Machine Management
Pack, No Media, 1-Server License, including 1 year of 24x7 Technical Support and
Updates NOTE: Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_na/12328_na.html | 452153-B21 | |
| NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to: http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials QuickSpecs for more information. | ||
| | ||
| Communications | HP NC360T PCI Express Dual Port Gigabit Server Adapter | 412648-B21 |
| HP NC373F PCI Express Multifunction Gigabit Server Adapter | 394793-B21 | |
| HP NC373T PCI Express Multifunction Gigabit Server Adapter | 394791-B21 | |
| HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter |
313881-B21
|
|
| HP NC7771 PCI-X 1000T Gigabit Server Adapter | 290563-B21 | |
|
|
||
| Redundant Options | Hot Plug AC Redundant Power Supply Module (NEMA cord) |
355892-001 |
| Hot Plug AC Redundant Power Supply Module (IEC cord) |
355892-B21 | |
|
| ||
| Optical Drives | Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers) |
264007-B21 |
| Slimline CD-RW/DVD-ROM Combo Drive Option Kit | 331903-B21 | |
| HP DVD+R/RW 8X Slim | 383975-B21 | |
| | ||
| Diskette Drives | Floppy Drive Option Kit |
364507-B21 |
|
| ||
| Hard Drives | Ultra320 SCSI – Universal Hot Plug | |
| HP 300 GB U320 10K Universal HDD | 350964-B22 | |
| HP 146 GB U320 10K Universal HDD | 286716-B22 | |
| HP 72 GB U320 10K Universal HDD |
286714-B22 | |
| HP 300 GB U320 15K Universal HDD |
411089-B22 | |
| HP 146 GB U320 15K Universal HDD |
347708-B22 | |
| HP 72 GB U320 15K Universal HDD |
286778-B22 | |
| HP 36 GB U320 15K Universal HDD |
286776-B22 | |
| NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320 transfer rates. | ||
| NOTE:
Please see the Hard Drive QuickSpecs for Technical Specifications such as
capacity, height, width, interface, transfer rate, seek time, physical configuration,
and operating temperature: http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.html | ||
| | ||
| Redundant Storage Controller |
Modular Smart Array 500 G2 Redundant Controller Option Kit |
335881-B21
|
|
|
||
| Modular Smart Array 500 G2 High Availability Kit | Modular Smart Array 500 G2 High
Availability Kit NOTE: Includes MSA500 G2 controller, MSA500 G2 4-port IO Module, Smart Array Multipath Software, two Smart Array 642 Adapters and two 6 foot SCSI Cables |
360229-B21
|
|
|
||
| 4-Port I/O module | MSA500 G2 4-Port I/O Module with Smart Array Multipath Software and two 6 foot SCSI Cables |
335882-B21 |
| | ||
| SCSI Configuration Kit | SCSI Configuration
Kit NOTE: Kit Includes duplex drive backplane terminator and 2 long SCSI cables. |
364471-B21 |
| | ||
| Storage Controllers | SCSI Controllers | |
| 128MB
Battery-Backed Write Cache with Battery Housing NOTE: Upgrade for Smart Array 6i controller. |
346914-B21 | |
| Smart Array 642 Controller | 291967-B21 | |
| 128MB Battery-Backed Cache Enabler NOTE: This 128MB BBWC supports the Smart Array 642 Controller. |
351580-B21 | |
| 256MB Battery Backed Cache Module | 254786-B21 | |
| NOTE: Please
see the following Controller or SCSI Adapter QuickSpecs for Technical Specifications
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak
Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support,
and additional information: | ||
| | ||
| Management Options | Remote Insight Lights-Out Edition II | 227251-001 |
| | ||
|
Tape Drives | NOTE:
For the complete listing of Tape Drive offerings, please see: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html For recommended tape drive offerings for this ProLiant server see the following: | |
| SCSI Tape Drives | ||
| NOTE: For the DL380 G4 Packaged Cluster, HP recommends purchasing the HP 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2 (374654-B21) for a dedicated SCSI HBA for tape. | ||
| HP StorageWorks LTO-2 Ultrium 448 SCSI Internal Tape Drive (Carbonite) | DW016A | |
| HP StorageWorks LTO-3 Ultrium 920 SCSI Internal Tape Drive |
EH841A | |
| HP StorageWorks 3U SCSI Rack-Mount with 1 LTO-4 Ultrium 1840 Tape Drive |
EH926A | |
NOTE:
Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for additional options
such as controllers, media, and other related items: For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect. | ||
| Rack-Mount Tape Drive Enclosures | ||
| HP StorageWorks 1U SCSI Rack-Mount
kit NOTE: The 1U Rack-Mount Kit can support up to (2) half-height tape drives and is compatible with multiple Single-Ended and LVD SCSI tape drives including the DAT 40, DAT 72, DAT 160, DLT VS160, LTO-1 Ultrium 232, LTO-2 Ultrium 448 and LTO-3 Ultrium 920 tape drives. |
A7445B | |
| HP
StorageWorks 3U SCSI Rack-mount Kit NOTE: The 3U SCSI Rack-mount Kit can support up to (2) full-height or (4) half-height tape drives and is compatible with multiple LVD SCSI tape drives including DAT 40, DAT 72, DAT 160, DLT VS160, SDLT 600, LTO-1 Ultrium 232, LTO-2 Ultrium 460, LTO-2 Ultrium 448, LTO-3 Ultrium 920, LTO-3 Ultrium 960 and LTO-4 Ultrium 1840 tape drives. | 274338-B22 | |
| NOTE: Please
see the Rack-Mount Tape Drive Kits QuickSpecs for additional information regarding
these kits: http://h18000.www1.hp.com/products/quickspecs/10854_na/10854_na.html | ||
| | ||
| Tape
Autoloaders | HP StorageWorks DAT Autoloader | |
| HP StorageWorks DAT 72x10 tape autoloader | AE313B | |
| HP StorageWorks 1/8 Tape Autoloader | ||
| HP StorageWorks 1/8 LTO-3 Ultrium 920 G2 Tape Autoloader | AH165A | |
| HP StorageWorks 1/8 LTO-2 Ultrium 448 G2 Tape Autoloader | AH164A | |
| HP StorageWorks 1/8 LTO-1 Ultrium 232 G2 Tape Autoloader | AH163A | |
| HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions. | AH166A | |
| NOTE: Please reference the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution. | ||
| | ||
| Tape Libraries | HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ033A | |
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1840 4GB FC Library | AJ034A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 960 SCSI Drive Library | AG115A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 960 4GB FC Library | AG326B | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SCSI Drive Library | AH169A | |
| HP StorageWorks MSL2024 1 LTO-2 Ultrium 448 SCSI Drive Library | AG116A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ035A | |
| HP StorageWorks MSL4048 1 LTO-4 Ultrium 1840 4GB FC Library | AJ036A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 960 SCSI Drive Library | AG322A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 960 4GB FC Library | AG324B | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SCSI Drive Library | AH171A | |
| HP StorageWorks MSL4048 1 LTO-2 Ultrium 448 SCSI Drive Library | AG320A | |
| HP StorageWorks MSL8096 Tape Library | ||
| HP StorageWorks MSL8096 2 LTO-4 Ultrium 1840 SCSI Drive Library | AJ039A | |
| HP StorageWorks MSL8096 2 LTO-4 Ultrium 1840 4GB FC Library | AJ040A | |
| HP StorageWorks MSL8096 2 LTO-3 Ultrium 960 4GB FC Library | AH218A | |
| HP StorageWorks MSL8096 2 LTO-3 Ultrium 960 SCSI Drive Library | AH219A | |
| HP StorageWorks MSL6000 Tape Library | ||
| LTO-4 Ultrium 1840 technology | ||
| HP StorageWorks MSL6030 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ029A | |
| HP StorageWorks MSL6030 1 LTO-4 Ultrium 1840 4GB FC Library | AJ030A | |
| HP StorageWorks MSL6060 2 LTO-4 Ultrium 1840 SCSI Drive Library | AJ031A | |
| HP StorageWorks MSL6060 2 LTO-4 Ultrium 1840 4GB FC Library | AJ032A | |
| Ultrium 960 technology | ||
| HP StorageWorks MSL6030 1 LTO-3 Ultrium 960 SCSI Drive Library | AD606B | |
| HP StorageWorks MSL6030 1 LTO-3 Ultrium 960 4GB FC Library | AD608B | |
| HP StorageWorks MSL6030 2 LTO-3 Ultrium 960 SCSI Drive Library | AD607B | |
| HP StorageWorks MSL6030 2 LTO-3 Ultrium 960 4GB FC Library | AD609B | |
| NOTE: Please reference the MSL2024, MSL4048 and MSL6000 Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs. | ||
| | ||
| Uninterruptible Power Systems – Rack | HP, R1.5kVA UPS,1U | AF419A |
| HP R3000 VA UPS, 2U, L5-30 |
AF422A | |
| HP R3000 VA UPS, 2U, L6-20 | AF423A | |
| HP R5500 VA UPS |
AF426A | |
| | ||
| HP Monitored Power Distribution Unit (PDU) | HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 17.3 kVA S2324 Monitored PDU- dual input, 3U, 24A | AF503A | |
| HP 8.3 kVA S1324 Monitored PDU- single input, 3U, 24A | AF504A | |
| HP 16.6 kVA S2140 Monitored PDU- dual input, 1U, 40A | AF505A | |
| HP 8.6 S1140 Monitored PDU- single input, 1U, 40A | AF506A | |
| | ||
|
Modular PDUs 1U/0U | 3.6kVA Model - mPDU, 16A, High | 252663-B24 |
| 2.8 kVA Model - mPDU, 24A, Low | 252663-D71 | |
| 4.9kVA Model - mPDU, 24A, High | 252663-D72 | |
| 8.3kVA Model - mPDU, 40A, High |
252663-B21 | |
| 8.3kVA Model - mPDU, 40A, High (power cord attached) |
252663-D73 | |
| 8.3kVA Model - mPDU 40A, High (core only) |
252663-D75 | |
| 4.9kVA Model - mPDU 24A, High (core only) |
252663-D74 | |
| NOTE:
Please see the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs)
QuickSpecs for additional options including shorter jumper cables and country
specific power cords: http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.html | ||
| | ||
| USB Options | HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) |
DC172B |
| USB 1.44-MB External Diskette Drive (Carbonite) |
DC141B | |
| HP USB 04 Standard Keyboard | DT528A#
ABA | |
| HP 1GB USB 2.0 Floppy Drive Key | 442085-B21 | |
| HP 256MB USB 2.0 Floppy Drive Key | 442084-B21 | |
| | ||
| HP Racks - for standard cluster with 8U configuration fixture (non-rack model) | ||
| HP Rack 5000 Series (Graphite Metallic) | HP
5642 Rack-Unassembled |
358254-B21 |
|
| ||
|
HP Rack 10000 G2 Series (Carbon/Graphite Metallic) | 10642 G2 (42U) Rack Cabinet - Pallet |
AF001A |
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A | |
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A | |
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet |
AF004A | |
| 10636 G2 (36U) Rack Cabinet - Pallet |
AF011A | |
| 10636 G2 (36U) Rack Cabinet - Shock Pallet |
AF012A | |
| 10636 G2 (36U) Rack Cabinet - Crated |
AF013A | |
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet |
AF014A | |
| 10622 G2 (22U) Rack Cabinet - Pallet |
AF021A | |
| 10622 G2 (22U) Rack Cabinet - Shock Pallet |
AF022A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Pallet |
AF041A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet |
AF042A | |
| 10647 G2 (47U) Rack Cabinet - Pallet |
AF031A | |
| NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed. | ||
| NOTE: Please
see the Rack 10000 G2 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_na/12402_na.html | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
|
HP Rack 10000 Series (Graphite Metallic) | HP Rack 10614 (14U) - Shock Pallet | 292302-B22 |
| NOTE: xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). xxxxxx-B23 (crated) used for air shipments of empty racks. | ||
|
NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. Not all equipment is qualified to be shipped in the Rack 10000 series | ||
|
NOTE: Please see the Rack 10000 QuickSpecs
for Technical Specifications such as height, width, depth, weight, and color: | ||
|
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
| ||
|
Keyboards and Monitors | TFT7210R Rack Mounted 17" Monitor |
348373-B21 |
| TFT7600 Rackmount Keyboard Monitor | AG052A | |
| 1U Rackmount Keyboard with USB |
AG072A | |
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
| HP KVM Switch Options | 2x1x16 IP Console Switch with Virtual Media |
AF601A
|
| 4x1x16 IP Console Switch with Virtual Media |
AF602A
|
|
| 2x16 Server Console Switch with Virtual Media |
AF600A
|
|
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A
|
|
| Server Console Switch (KVM), 0 x 1 x 8 port |
336044-B21
|
|
| Server Console Switch (KVM), 0 x 2 x 16 port |
336045-B21
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| USB Interface Adapter, 1 pack |
336047-B21
|
|
| Serial Interface adapter - 1 Pack with power supply |
373035-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x4 Console Switch |
AF611A
|
|
| PS2 Server Console Cable, 6 ft, 2 pack |
AF612A
|
|
| USB Server Console Cable, 6 ft, 2 pack |
AF613A
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| HP Serial Console Server Options | HP 16 Port Serial Console Server |
AF101A |
| HP 48 Port Serial Console Server |
AF102A | |
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A | |
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A | |
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
| | ||
| Rack Options for Third Party Cabinet Racks | Round
hole rack cabinet rail kit NOTE: Support for racks with round mounting holes (include HP Rack System /E and HP Systems) with an adjustment range of 24"- 36". |
293052-B21 |
|
| ||
| Service and Support Offerings (HP Care Pack Services) |
|
||||||||||
|
|||||||||||
|
|||||||||||
|
|||||||||||
|
|
|
Memory
| HP ProLiant DL385 server |
|
Standard Memory Standard Memory Plus Optional Memory Standard Memory Replaced with Optional Memory NOTE: Chart does not represent all possible memory configurations (slots 5 - 8 are available when second processor is added). |
|
Memory |
Slot |
||||||||
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7 | 8 | |
|
Standard |
1 GB |
Empty |
Empty |
512 MB |
512 MB |
Empty |
Empty |
Empty |
Empty |
|
Optional |
25 GB |
4 GB | |||||||