Overview
|
HP StorageWorks SB40c storage blade
|
||||||||||||||||||||
| What's New |
|
|
|
| At A Glance |
|
|
|
| Models | |
|
The SB40c allows for the mix of SAS and SATA drives in the same enclosure at the same time and is tailored to the needs of HP server blade customers who require optimized direct attach storage. |
|
| HP StorageWorks SB40c storage blade |
411243-B21
|
|
|
Product Highlights
| Key Features | Features of the SB40c include: |
| SFF (SAS/SATA) support - Delivering data transfer rates up 3Gb/s for SAS and 1.5Gb/s for SATA | |
|
|
|
|
|
| Mix and Match of Hard Drive Types | A benefit of SAS and SATA is the use of a common physical connection which allows for both drive types to be mixed together on the same backplane. This common backplane allows customers the choice of using SAS and/or SATA and helps deliver HP's message of industry leading innovation, reliability, adaptability, and performance by allowing customers to choose the reliability of SAS or the lower cost of SATA for tiered storage. |
|
|
|
| Hot Pluggable | Hot pluggable technology is designed into drives, fans and redundant power supplies. Hot pluggable components can be replaced without powering down the storage system or stopping I/O operations. This feature significantly enhances data availability. |
|
|
|
| Universal Hard Drive | Form factor is for use across multiple HP ProLiant servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives. |
|
|
|
| LED Indicators | Front panel LEDs indicate drive activity and system health status. |
|
|
|
| Density | The SB40c fits into a half height bay on the BladeSystem c3000 and c7000 Enclosure. |
|
|
|
| Fault Tolerance | Using the internal Smart Array P400 controller with 256MB DDR2 BBWC, the SB40c can be configured for RAID levels 0, 1, 1 + 0, 5, and 6 (RAID ADG) |
|
|
|
| Manageability | All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the HP server storage. |
|
|
|
| Fault Prevention |
The following features offer detection of possible failures before they
occur, allowing preventive action to be taken:
|
|
|
|
| Compatibility and Integration Testing | Intensive compatibility and performance testing with HP BladeSystem c-Class server blades for the highest level of integration available in the industry. |
|
|
|
| Product Kit Contents | 5 drive blanks, warranty card, mounting hardware, Enclosure user guide, HP SmartStart CD Kit, documentation CD |
|
|
|
| Operating Systems |
Microsoft Windows Server 2003, Standard Edition |
| NOTE: For more Linux OS support & certification information, please visit our the ProLiant & Bladesystem Server Linux matrix http://h18004.www1.hp.com/products/servers/linux/hpLinuxcert.html | |
|
|
|
| Software Suite |
Systems Insight Manager
HP Array Configuration Utility (ACU)
HP Option ROM Configuration for Arrays (ORCA)
HP Array Diagnostic Utility (ADU)
|
|
|
Service and Support, HP Care Pack, and Warranty Information
| Warranty |
Protected by HP Services and a worldwide network of HP Authorized Channel Partners. Three-year parts, 3 Year Labor and 3 Year on-site limited global warranty. Certain restrictions and exclusions apply. |
|
Hard drive Pre-Failure Warranty: When used with any one of the Smart Array Family controllers and monitored under HP Systems Insight Manager (v4.20 or later), HP hard drives are supported by a Pre-Failure (replacement) Warranty. SATA hard drives have a one year warranty. |
|
|
|
|
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners. Hardware diagnostic support and repair is available for three years from date of purchase. Support for software and initial setup is available for 90 days from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. HP services provide total care and support expertise with committed response designed to meet your IT and business needs. To fully capitalize on your HP BladeSystem servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a HP BadeSystem server support offer to help you speedily deploy and maximize system uptime. Recommended Service - simplify ProLiant solution implementation,
maintenance, and management.
Enhanced Service - optimize service level to increase IT performance
and availability.
Deployment Services - HP Installation and Start Up services designed
to take time, risk, and worry out of the deployment of HP BladeSystem
servers - and free customers IT support staff to focus on what they do
best, their business.
For a complete listing of service offerings and information visit: |
|
|
Configuration Information - Factory Integrated Models (North America Only)
|
NOTE: For Configure to Order requirements within EMEA region,
please consult local Sales Contact. |
|||
| Step 1: Base Storage Blade Configuration | |||
| Models | HP BLc SB40c CTO Storage Blade |
434879-B21
|
|
| Configurable Model ships with: | |||
| HP Smart Array P400/256 | |||
| Standard Power Supplies | |||
| Standard System Fans | |||
| 6 hard drive bays | |||
|
|
|||
| Step 2: Choose Required Options (at least one of the following from each list unless otherwise noted): | ||
| Hard Drives | SFF Serial Attached SCSI (SAS) Hard Drives | |
| HP 72GB 3G SAS 15K SFF DP HDD |
418371-B21
|
|
| HP 72GB 3G SAS 15K SFF SP HDD |
431935-B21
|
|
| HP 36GB 3G SAS 15K SFF DP HDD |
418369-B21
|
|
| HP 36GB 3G SAS 15K SFF SP HDD |
431933-B21
|
|
| HP 146GB 3G SAS 10K SFF DP HDD |
418367-B21
|
|
| HP 146GB 3G SAS 10K SFF SP HDD |
431958-B21
|
|
| HP 72GB 3G SAS 10K SFF DP HDD |
384842-B21
|
|
| HP 72GB 3G SAS 10K SFF SP HDD |
375861-B21
|
|
| SFF Serial-ATA (SATA) Hard Drive | ||
| HP120GB SFF SATA 5.4K HDD |
431786-B21
|
|
| NOTE: Up to 6 hard drives may be chosen. SAS drives are installed first then SATA drives. Smallest capacity drives are installed first. Matching drives are grouped together. | ||
|
|
Options
| NOTE: Some of the options listed below may be discontinued. | ||
|
|
| c-Class Mezzanines | HP PCI Express Mezzanine pass-thru card for HP BladeSystem |
431643-B21 |
| NOTE: Required to support the HP StorageWorks SB40c Storage Blade (P/N 411243-B21) with HP c-Class BladeSystem full-height server blades | ||
|
|
||
| Hard Drives | SFF Serial Attached SCSI (SAS) Hard Drives | |
| HP 72GB 3G SAS 15K SFF DP HDD |
418371-B21
|
|
| HP 72GB 3G SAS 15K SFF SP HDD |
431935-B21
|
|
| HP 36GB 3G SAS 15K SFF DP HDD |
418369-B21
|
|
| HP 36GB 3G SAS 15K SFF SP HDD |
431933-B21
|
|
| HP 146GB 3G SAS 10K SFF DP HDD |
418367-B21
|
|
| HP 146GB 3G SAS 10K SFF SP HDD |
431958-B21
|
|
| HP 72GB 3G SAS 10K SFF DP HDD |
384842-B21
|
|
| HP 72GB 3G SAS 10K SFF SP HDD |
375861-B21
|
|
| SFF Serial-ATA (SATA) Hard Drive | ||
| HP120GB SFF SATA 5.4K HDD |
431786-B21
|
|
| NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility information (http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data. |
|
|
Storage
|
1-6
|
6 x SFF SAS or SATA Hot Plug Hard Drives |
| Hard Drives | |||
| SFF Serial Attached SCSI (SAS) Hard Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller |
|
| 36GB 15,000 rpm SAS SFF 72GB 15,000 rpm SAS SFF S 72GB 10,000 rpm SAS SFF 146GB 10,000 rpm SAS |
6
|
1-6
|
Smart Array P400 Controller |
|
|
|||
| SFF Serial-ATA (SATA) Hard Drive | |||
|
Quantity
Supported |
Position
Supported |
Controller |
|
|
120GB 5400rpm SATA |
6
|
1-6
|
Smart Array P400 Controller |
|
|
Technical Specifications
| HP StorageWorks SB40c storage blade | Dimensions (HxWxD) | 2.19 x 7.154 x 20.058 in (5.56 x 18.17 x 50.95 cm) | |
| Weight (unloaded) | 8 lb (3.63 kg) | ||
| Weight (loaded) | 11 lb (4.99 kg) | ||
| Protocol Support | 3Gb/s SAS 1.5Gb/s SATA |
||
| O/S Support | Defined by specific HP array controller or SAS/SATA adapter used; please refer to the QuickSpecs and/or User Guide of the specific array controller or adapter | ||
| LED Indicators | UID | ||
| System Health LED | |||
|
Drive LED Indicators (on drive trays) |
Drive LED (top) - On-line/Activity | ||
| Drive Failure LED (bottom) - Drive Fault/Locate | |||
|
Relative Humidity (non-condensing) |
Operating | 10% to 90% | |
| Shipping | 5% to 95% | ||
| Temperature Range | Operating |
50° to 94° F (10° to 35° C°) | |
| Shipping | -22° to 140° F (-30° to 60° C) | ||
| NOTE: To maintain proper cooling and airflow, a drive blank or drive must occupy all bays during operation. | |||
|
|
|||
| Smart Array P400 Controller |
Disk Drive and Enclosure Interface |
3G SAS (Serial Attached SCSI) |
| 1.5G SATA (Serial Advanced Technology Attachment) | ||
|
SAS Connectors |
2 internal (SFF8484) x4 wide port connectors | |
|
Cache Memory Speed |
DDR2-533MHz with provides up to 4.2 GB/s maximum bandwidth. | |
|
SAS Speed |
x8 3G SAS provides 2.4GB/s maximum bandwidth. | |
|
Cache Memory |
40-bit 256MB cache; ECC protection, battery-backed, and transportable | |
|
Logical Drives Supported |
Up to 32 logical drives | |
|
Maximum Logical Drive Capacity |
876GB (6 x 146GB) | |
|
Host Memory Addressing |
64-bit, supporting greater than 4GB server memory space | |
|
RAID Support |
RAID 6 with ADG (Advanced Data Guarding) | |
| RAID 5 (Distributed Data Guarding) | ||
| RAID 1+0 (Striping & Mirroring) | ||
| RAID 0 (Striping) | ||
|
Upgradeable Firmware |
Upgradeable Firmware with recovery ROM feature | |
|
|
||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|
|
|||
|
© Copyright 2008 Hewlett-Packard Development Company, L.P. The only warranties for HP products and services are set forth in the
express warranty statements accompanying such products and services. Nothing
herein should be construed as constituting an additional warranty. HP
shall not be liable for technical or editorial errors or omissions contained
herein. |