|
|
Overview
|
HP Integrity rx3600 Server |
|
|
|
HP Integrity rx3600 System Overview (Interior
View) | |||
![]() | |||
| 1. | Hot Swap Fans | 3. | 2 Clamshell CPU Sockets |
| 2. | 8 SAS HDDs | 4. | 8 or 24 DDR2 DIMM Slots |
| HP Integrity rx3600 | |||
![]() | |||
| 1. | 8 Hot Plug PCI-X IO Slots (2 @ 266 MHz) | 2. | Redundant Bulk Power |
| At A Glance |
|
|
|
Standard Features
| Minimum System |
|
| | |
| Maximum Server Capacities |
|
| | |
| Standard System Features |
|
|
| |
| High Availability |
|
|
| |
| Security |
|
| | |
| Manageability - Deploy |
|
| Manageability - Monitor |
|
| Manageability - Optimize |
|
|
|
Configuration
| Processor Configuration | The HP Integrity rx3600 is a symmetrical multiprocessing (SMP) server supporting up to two high performance 64 bit dual core Intel Itanium processors. The dual core Intel Itanium processor supports hyper threading. Each core of the processor supports two threads. |
| | |
| Processor Details |
Dual core Intel Itanium 2 processors:
All processors support:
|
|
| |
| Processor Configuration Rules |
|
|
|
|
| Memory Configuration |
The HP Integrity rx3600 supports double data rate (DDR2) synchronous dynamic random access memory (SDRAM) DIMMs with ECC and double chip spare protection. The HP Integrity rx3600 can be ordered with one of the following two memory carrier boards:
|
| Memory Loading Rules | |
| |
|
| |
| Memory Options | |
| Description | Product Number |
| 2-GB Chip Spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM memory pair (2×1GB DIMMs) | AH350A |
| 4-GB Chip Spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×1GB DIMMs) | AB564A |
| 8-GB Chip Spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×2GB DIMMs) | AB565A |
| 16-GB Chip Spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×4GB DIMMs) | AB566A |
| 32-GB Chip Spare PC2 4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×8GB DIMMs) | AH405A |
| Server Form Factor and Rack Configuration | The HP Integrity rx3600 is a 4U
rack optimized server. It is supported in HP 10000 G2 series cabinets. For
factory integration order AD053A with 0D1 feature code. Sliding mounts and
a cable management arm will be installed with the server in a factory integrated
rack.
The HP Integrity rx3600 can be installed in the field with the Field Rack Kit (AD053A with B01 feature code). This field kit contains the slide mounts, cable management arm, and all other hardware needed to mount an rx3600 into a 19 inch cabinet. Refer to the 10000 G2 Series Rack Best Practices Guide for information on rack deployment, stabilization and transportation. Go to http://www.hp.com/go/rackandpower for more information. The rx3600 is also available in a stand alone, pedestal form factor (AD054A). Kit will be shipped in the same box with the system and is field installable only. |
|
| |
| I/O Architecture |
| The HP Integrity rx3600 supports
two I/O backplane options in order to provide maximum flexibility, I/O card
availability, performance, scalability and reliability. The two options
are a PCI-X 2.0 Backplane (AD295A#100) or a PCI-Express/PCI-X Backplane
option (AD295A#300). Only one backplane per system is supported. PCI-X 2.0 Backplane: This backplane provides ten PCI-X I/O slots, two of which are reserved for Core I/O cards and eight which are available for I/O card expansion. The Core I/O slots will always be filled with either an HP PCI-X 8 Internal Port Serial Attached SCSI (SAS) host bus adapter (for HP UX and OVMS systems) or an HP PCI-X Smart Array (P600) 8 Internal Port Serial Attached SCSI (SAS) card (for Windows and Linux systems) (slot #1) and a PCI-X dual port 10/100/1000Base TX LAN adapter (slot #2). A second host bus adapter is supported as a core I/O controller, but is not available for standard factory installation; it must be installed via Factory Express or in the field. When a second host bus adapter is ordered, it must be installed in slot #2, and the LAN adapter moved to slot #10. HP-UX and OpenVMS based systems with PCI-X 2.0 Backplane: Windows and Linux based systems with PCI-X 2.0 backplane: Remaining Eight (non-Core I/O) slots: The remaining four slots (#7 through #10) share two 64 bit 66 MHz PCI-X
buses, with two slots allocated to each bus. Each pair of slots shares
a 0.5 GB/s I/O channel. NOTE: Hot-plug operations are not supported with the Linux or OpenVMS operating systems nor in Core I/O slots. All I/O slots are keyed for I/O cards with 3.3V signaling. Cards that use 5V signaling are not supported in the HP Integrity rx3600. PCI-Express/PCI-X Backplane: Each port of a Serial Attached SCSI card can be connected to a Serial Attached SCSI hard disk drive, therefore each HP PCI-X 8 port SAS card supports eight hard disks drives. HP-UX and OpenVMS based systems with PCI-Express/PCI-X Backplane:
Windows and Linux based systems with PCI-Express/PCI-X Backplane:
Remaining Eight (non-Core
I/O) slots: The remaining four slots (#7 through #10) are PCI-X slots. Slots #7 and #8 each have their own dedicated 64 bit 133 MHz PCI-X slot; slot #7 is 1.1 GB/s and #8 is .5 GB/s. Slots #9 and #10 share a 64-bit 66-MHz PCI-X 0.5 GB/s I/O channel. NOTE: Hot plug operations are not supported with the Linux or OpenVMS operating systems or for the PCI-X Core I/O slots for any operating system. Hot plug operations are not supported for any operating system in slots #3 or #4. All I/O slots are keyed for I/O cards with 3.3V signaling. Cards that use 5V signaling are not supported in the HP Integrity rx3600. |
| Supported I/O Cards |
| Supported HP-UX I/O Cards |
| I/O Card |
Product Number
|
PCIe/
PCI-X |
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane |
Maximum Cards
PCI-Express/PCI-X Backplane |
Special Notes
|
| Multi function Cards (Mass Storage/LAN) | |||||||
| HP PCI-X 1 port 4 GB Fibre Channel/1 port 1000Base T Adapter |
AD193A
|
PCI-X
|
Yes
|
1 LC, 1 RJ 45
|
8
|
4
|
|
| HP PCI-X 2 port 4 GB Fibre Channel/2 port 1000Base T Adapter |
AD194A
|
PCI-X
|
Yes
|
2LC, 2 RJ 45
|
8
|
4
|
|
| PCI-X 2 Gb Fibre Channel/1000Base-SX |
A9782A
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
For maximum performance, card should not be installed
in a shared slot.
|
| PCIe 4-Gb Fibre Channel/GbE-T HBA combo |
AD221A
|
PCIe
|
Yes
|
-
|
0
|
4
|
HP-UX 11i v3 required
|
| PCIe 2-port 4-Gb Fibre Channel/2-port GbE-T HBA combo |
AD222A
|
PCIe
|
Yes
|
-
|
0
|
4
|
HP-UX 11i v3 required
|
| PCIe 2-port 4-Gb Fibre Channel/2-port GbE-SX HBA combo |
AD393A
|
PCIe
|
Yes
|
-
|
0
|
4
|
HP-UX 11i v3 required
|
| PCI-X 2 port 1000Base T/2 port U320 Multi function Adapter |
AB290A
|
PCI-X
|
Yes
|
SCSI - LVD/SE
LAN - RJ 45 |
8
|
4
|
|
| Local Area Network (LAN) Adapters | |||||||
| PCI-X 1-port 1000Base-T (gigabit
copper) |
AD331A
|
PCI-X
|
Yes
|
RJ-45
|
8
|
4
|
|
| PCI-X 2-port 1000Base-T |
A7012A
|
PCI-X
|
Yes
|
RJ-45
|
8
|
4
|
|
| PCI-X 4 port 1000Base T 1GbE Adapter |
AB545A
|
PCI-X
|
Yes
|
RJ 45
|
8
|
4
|
|
| Single-port GigE-SX adapter card for HP-UX (Half-length, PCI-X card) |
AD332A
|
PCI-X
|
Yes
|
8
|
4
|
||
| PCI-X 2 port 1000Base SX |
A7011A
|
PCI-X
|
Yes
|
Duplex SC
|
8
|
4
|
|
| HP PCIe 2-port 1000Base-T card |
AD337A
|
PCIe
|
Yes
|
RJ-45
|
0
|
4
|
|
| HP PCIe 2-port 1000Base-SX card |
AD338A
|
PCIe
|
Yes
|
Duplex SC
|
0
|
4
|
|
| HP PCIe 10GbE SR card | AD386A | PCIe | Yes |
0
|
4
|
|
|
| HP NC364T PCIe 4PT Gigabit Server Adapter | AD339A | PCIe | Yes | |
0 | 4 |
|
| PCI-X 266-MHz 1 port 10GbE | AD385A | PCI-X | Yes | Duplex LC | 4 | 2 | For best performance, recommend at least one processor core per card installed in the system. Each card requires 512 MB of memory. Card cannot be installed in a shared slot. |
| Fibre Channel Storage Host Bus Adapters | |||||||
| HP PCI2 1-port 4-Gb/s Fibre Channel HBA |
AD299A
|
PCIe
|
No
|
LC
|
0
|
2
|
|
| HP PCI2 2-port 4-Gb/s Fibre Channel HBA |
AD355A
|
PCIe
|
No
|
LC
|
0
|
2
|
|
| PCI X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AB378B
|
PCI X
|
Yes
|
LC
|
8
|
4
|
|
| PCI X 266 MHz 2 channel 4 Gb/s Fibre Channel |
AB379B
|
PCI X
|
Yes
|
LC
|
8
|
4
|
|
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
2
|
|
| HP PCIe 1-port 8Gb FC SR (Qlogic) HBA |
AH400A
|
PCIe
|
Yes
|
-
|
0
|
4
|
HP-UX 11i v3 required
|
| HP PCIe 2-port 8Gb FC SR (Qlogic) HBA |
AH401A
|
PCIe
|
Yes
|
-
|
0
|
4
|
HP-UX 11i v3 required
|
| HP PCIe 1-port 8Gb FC SR (Emulex) HBA |
AH402A
|
PCIe
|
Yes
|
-
|
0
|
4
|
HP-UX 11i v3 required
|
| HP PCIe 2-port 8Gb FC SR (Emulex) HBA |
AH403A
|
PCIe
|
Yes
|
-
|
0
|
4
|
HP-UX 11i v3 required
|
| SCSI Adapters | |||||||
| PCI 2 channel Ultra320 SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
8
|
4
|
|
| PCI-X 2 channel Smart Array 6402 Ultra320 |
A9890A |
PCI-X
|
Yes
|
VHDCI
|
6
|
2
|
Requires minimum of 512 MB of memory and full
length slot
|
| PCI-X 4 channel Smart Array 6404 Ultra320 |
A9891A
|
PCI-X
|
Yes
|
VHDCI
|
6
|
2
|
Requires minimum of 512 MB of memory and full
length slot
|
| SAS RAID Adapters Cards | |||||||
| HP PCIe SC44Ge SAS HBA |
AH303A
|
PCIe
|
Yes
|
0
|
4
|
-
|
|
| PCIe Smart Array P800 |
AD335A
|
PCIe
|
No
|
Mini SAS
|
0
|
4
|
|
| Wide Area Network (WAN) Adapters | |||||||
| 2 port Programmable Serial Interface (PSI) X.25/Frame Relay/SDLC |
J3525A
|
J3525A
|
No
|
RS 530, RS 232, V.35, RS 449 or X.21
|
8
|
4
|
|
| PCIe 2-port 4X DDR Fast IB HCA |
AH304A
|
PCIe
|
No
|
-
|
0
|
4
|
-
|
| Cluster Interconnect | |||||||
| PCI-X 2 port 4x Fabric (HPC) Adapter |
AB286C
|
PCI-X
|
No
|
4x Infiniband Copper
|
8
|
4
|
For maximum performance, card should not be installed
in a shared slot. Requires a minimum of 512 MB memory.
|
| PCIe 2-port 4X DDR Fast IB HCA |
AH304A
|
PCIe
|
No
|
0
|
4
|
HP-UX 11i v3 required
|
|
| PCI 8 port Serial MUX Adapter |
AD278A
|
PCI-X
|
No
|
8
|
4
|
||
| PCI 64 port Serial MUX Adapter |
AD279A
|
PCI-X
|
No
|
8
|
4
|
||
| 16 port RS 232 RJ-45 Port Module |
AD280A
|
No
|
4 per AD279A
|
N/A
|
N/A
|
AD280A #001 Port Module Power Supply, required on Port
Module (3) and Port Module (4) connected to an AD279A 64 port MUX adapter.
|
|
| 16-port RS-232 DB-25 Port Module |
AD281A
|
No
|
4 per AD279A
|
N/A
|
AD281A #001 Port Module Power Supply, required on Port
Module (3) and Port Module (4) connected to an AD279A 64 port MUX adapter.
|
||
| Graphics Adapters | |||||||
| HP 2D PCI-X graphics card |
AH391A
|
PCI
|
No
|
VGA
|
2
|
2
|
T/P/I: HP UX PCI-x and PCI-x/PCI-e 2/2/2
|
| Supported OpenVMS I/O Cards |
| I/O Card |
Product Number
|
PCIe/
PCI-X |
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane |
Maximum Cards
PCI-Express/PCI-X Backplane |
Special Notes
|
| Multi function Cards (Mass Storage/LAN) | |||||||
| HP PCI X 1 port 4 GB Fibre Channel/1 port 1000Base T Adapter |
AD193A
|
PCI X
|
Yes
|
1 LC, 1 RJ 45
|
2
|
2
|
|
| HP PCI X 2 port 4 GB Fibre Channel/2 port 1000Base T Adapter |
AD194A
|
PCI X
|
Yes
|
2LC, 2 RJ 45
|
2
|
2
|
|
| PCI X 2 Gb Fibre Channel/1000Base SX |
A9782A
|
PCI X
|
Yes
|
LC
|
4
|
4
|
For maximum performance, card should not be installed
in a shared slot.
|
| PCI X 2 port 1000Base T/2 port U320 Multi function Adapter |
AB290A
|
PCI X
|
Yes
|
SCSI - LVD/SE
LAN - RJ 45 |
2
|
2
|
Requires full length slot.
|
| PCIe 4-Gb Fibre Channel/GbE-T
HBA combo |
AD221A
|
PCIe
|
Yes
|
-
|
0
|
2
|
|
| PCIe 2-port 4-Gb Fibre Channel/2-port
GbE-T HBA combo |
AD222A
|
PCIe
|
Yes
|
-
|
0
|
2
|
|
| PCIe 2-port 4-Gb Fibre Channel/2-port GbE-SX HBA combo |
AD393A
|
PCIe
|
Yes
|
-
|
0
|
2
|
|
| Local Area Network (LAN) Adapters | |||||||
| PCI-X 1 port 1000Base-T (gigabit copper) |
AD331A
|
PCI-X
|
No
|
RJ-45
|
8
|
4
|
|
| PCI-X 2 port 1000Base T |
A7012A
|
PCI-X
|
No
|
RJ 45
|
8
|
4
|
|
| PCI-X 4 port 1000Base T 1GbE Adapter |
AB545A
|
PCI-X
|
No
|
RJ 45
|
3
|
3
|
|
| PCI-X 1 port 1000Base-SX (gigabit fiber) |
AD332A
|
PCI-X
|
No
|
Duplex SC
|
8
|
4
|
|
| PCI-X 2-port 1000Base-SX |
A7011A
|
PCI-X
|
No
|
Duplex SC
|
8
|
4
|
|
| HP PCIe 2-port 1000Base-T Card |
AD337A
|
PCIe
|
Yes
|
Duplex SC
|
0
|
4
|
|
| HP PCIe 2-port 1000Base-SX card |
AD338A
|
PCIe
|
Yes
|
Duplex SC
|
0
|
4
|
|
| HP NC364T PCIe 4PT Gigabit Server Adapter | AD339A | PCIe | No | 0 | 4 | ||
| HP PCI-X 266MHz 10GigE SR Card | AD385A | PCI-X | Yes | 2 | 2 | ||
| Fibre Channel Storage Host Bus Adapters | |||||||
| HP PCI2 1-port 4-Gb/s Fibre Channel HBA |
AD299A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| HP PCI2 2-port 4-Gb/s Fibre Channel HBA |
AD355A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AB378B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
2
|
|
| SCSI Adapters | |||||||
| PCI 2 channel Ultra320 SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
4
|
4
|
No On Line Add and Replace support.
|
| PCI-X 2 channel Smart Array 6402 Ultra320 | A9890A | PCI-X | Yes | VHDCI | 2 | 2 | Requires minimum of 512 MB of memory and full length slot |
| PCI-X 4 channel Smart Array 6404 Ultra320 | A9891A | PCI-X | Yes | VHDCI | 1 | 1 | Requires minimum of 512 MB of memory and full length slot |
| SAS RAID Adapters | |||||||
| HP PCIe SC44Ge SAS HBA | AH303A | PCIe | Yes | 0 | 4 | ||
| PCIe Smart Array P800 | AD335A | PCIe | No | Mini SAS | 0 | 4 | |
| Graphics Adapters | |||||||
| HP 2D PCI-X graphics card | AH391A | PCI | No | VGA | 4 | 3 | No OpenVMS factory
integration. AH391A offers 2D graphics support. Support available for OpenVMS 8.3-1h1 and 8.3. OpenVMS PCI-x 4/4/4, PCIe 3/3/3 |
| Supported Windows I/O Cards |
|
NOTE: |
| I/O Card |
Product Number
|
PCIe/
PCI-X |
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane |
Maximum Cards
PCI-Express/PCI-X Backplane |
Special Notes
|
| Local Area Network (LAN) Adapters | |||||||
| PCI 2 port Windows/Linux 1000Base-TX |
A9900A
|
PCI-X
|
No
|
RJ-45
|
6
|
4
|
No On Line Add and Replace support.
|
| PCI-X 2 port 1000Base SX | A7011A | PCI-X | Yes | Duplex SC |
6
|
4
|
|
| HP PCIe 2-port 1000Base-T card |
AD337A
|
PCIe
|
Yes
|
RJ-45
|
0
|
4
|
|
| HP PCIe 2-port 1000Base-SX card |
AD338A
|
PCIe
|
Yes
|
Duplex SC
|
0
|
4
|
|
| HP PCI-X 266MHz 10GigE SR Card |
AD385A
|
PCI-X
|
Yes
|
0
|
4
|
only Windows 2003 is supported | |
| HP PCI-X 266MHz 10GigE SR Card | AD385A | PCI-X | Yes | 2 | 2 | ||
| Fibre Channel Storage Network Adapters Cards | |||||||
| HP PCIe 1-port 8Gb FC SR (Qlogic)
HBA |
AH400A | PCIe |
Yes
|
- | 0 | 4 | |
| HP PCIe 2-port 8Gb FC SR (Qlogic) HBA | AH401A | PCIe |
Yes
|
- | 0 | 4 | |
| HP PCIe 1-port 8Gb FC SR (Emulex) HBA | AH402A | PCIe |
Yes
|
- | 0 | 4 | |
| HP PCIe 2-port 8Gb FC SR (Emulex) HBA | AH403A | PCIe |
Yes
|
- | 0 | 4 | |
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AB429A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AD167A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel |
AD168A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
| PCIe 1 port 4 Gb/s Emulex Fibre Channel |
A8002A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| PCIe 2 port 4 Gb/s Emulex Fibre Channel |
A8003A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| PCIe 1 port 4 Gb/s Fibre Channel |
AE311A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| SCSI Adapters | |||||||
| PCI 2 channel Ultra320 SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
2
|
2
|
|
| PCI-X 2 channel Smart Array 6402 Ultra320 | A9890A |
PCI-X |
Yes
|
VHDCI
|
2
|
2
|
|
| PCI-X 4 channel Smart Array 6404 Ultra320 | A9891A | PCI-X |
Yes
|
VHDCI
|
1
|
1
|
|
| PCIe Smart Array 500 |
AH226A
|
PCIe
|
Yes
|
Mini SAS
|
0
|
4
|
|
| SAS RAID Adapters Cards | |||||||
| PCIe Smart Array E500 | AH226A | PCIe | Yes | Mini SAS | 0 | 4 | |
| PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller (for external storage only) |
337972-B21
|
PCI-X
|
Yes
|
SFF8470
|
6
|
4
|
A maximum of (4) may be ordered with #0D1, the remaining
(2) must be ordered without #0D1
|
| 512 MB cache memory upgrade for SA640x and SA P600 controller |
372538-B21
|
PCI-X
|
NA
|
NA
|
NA
|
NA
|
|
| PCIe Smart Array P800 |
AD335A
|
PCIe
|
Yes
|
Mini SAS
|
0
|
4
|
|
| Supported Linux (RHEL 4 U4 and SLES 10) I/O Cards |
| I/O Card |
Product Number
|
PCIe/
PCI-X |
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane |
Maximum Cards
PCI-Express/PCI-X Backplane |
Special Notes
|
| Local Area Network (LAN) Adapters | |||||||
| PCI 2 port Windows/Linux 1000Base TX |
A9900A
|
PCI-X
|
Yes
|
RJ 45
|
8
|
4
|
No On Line Add and Replace support.
|
| PCI-X 4 port 1000Base T 1GbE Adapter |
AB545A
|
PCI-X
|
No
|
RJ 45
|
|
||
| PCI-X 2 port 1000Base SX |
A7011A
|
PCI-X
|
Yes
|
Duplex SC
|
8
|
4
|
|
| HP PCIe 2-port 1000Base-T card |
AD337A
|
PCIe
|
Yes
|
RJ-45
|
0
|
4
|
|
| HP PCIe 2-port 1000Base-SX card |
AD338A
|
PCIe
|
Yes
|
Duplex SC
|
0
|
4
|
|
| HP PCI-X 266MHz 10GigE SR Card |
AD385A
|
PCI-X
|
Yes
|
2
|
2
|
||
| Fibre Channel Storage Network Adapters Cards | |||||||
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AB429A
|
PCI-X
|
Yes
|
LC
|
4
|
4
|
Qlogic and Emulex HBAs are not supported in the same
server
|
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AD167A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel |
AD168A
|
PCI-X
|
Yes
|
LC
|
6
|
4
|
|
| PCIe 1 port 4 Gb/s Emulex Fibre Channel |
A8002A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| PCIe 2 port 4 Gb/s Emulex Fibre Channel |
A8003A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| PCIe 1 port 4 Gb/s Fibre Channel |
AE311A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| SCSI Adapters | |||||||
| PCI 2 channel Ultra320 SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
4
|
4
|
|
| PCI-X 2 channel Smart Array 6402 Ultra320 |
A9890A
|
PCI-X
|
Yes
|
VHDCI
|
2
|
2
|
Requires minimum of 512 MB of memory and full
length slot
|
| PCI-X 4 channel Smart Array 6404 Ultra320 |
A9891A
|
PCI-X
|
Yes
|
VHDCI
|
1
|
1
|
|
| SAS RAID Adapters | |||||||
| PCIe Smart Array E500 |
AH226A
|
PCIe
|
Yes
|
Mini SAS
|
0
|
4
|
|
| HP PCIe SC44Ge SAS HBA |
AH303A
|
PCIe
|
No
|
0
|
4
|
||
| PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller (for external storage only) |
337972-B21
|
PCI-X
|
Yes
|
SFF8470
|
4
|
4
|
|
| 512 MB cache memory upgrade for SA640x and SA P600 controller |
372538-B21
|
PCI-X
|
NA
|
NA
|
NA
|
NA
|
|
| PCIe Smart Array P800 |
AD335A
|
PCIe
|
Yes
|
Mini SAS
|
0
|
4
|
|
|
|
| Support Internal Storage Devices | Product Number |
| Device | |
| Internal Hard Drives | |
| 72 GB 15K RPM Hot Plug Serial Attached SCSI (SAS) 2.5 inch Drive | AD379A |
| 146 GB 10K RPM Hot Plug Serieal Attached SCSI (SAS) 2.5-inch Drive | AD333A |
| 300 GB 10K RPM Serial Attached SCSI (SAS) 2.5 inch Small Form Factor Hot Plug Disk | AM244A |
| HP Integrity 146GB 15K SAS SFF 3GB DP | AM302A |
| Removable Media2 | |
| DVD ROM Drive | AD142A |
| DVD+RW Drive3 | AD143A |
| 1 While
ordering Windows, please order at least 64GB HDD to support OS installation 2 Required for Windows, Linux, and OpenVMS. Optional for HP UX. Maximum 1 supported. 3 Third party software (not included with AD143A) is required to support DVD write with Windows on AD143A. For HP UX 11i v2, only DVD+R and DVD+RW media is supported. CD media is not supported |
| Integrated Multi-function Core I/O |
The integrated multifunction I/O provides core I/O functionally and includes
the integrated management processor, which provides remote management
and high availability monitoring capabilities.
|
| | |
| Integrated Integrity iLO 2 Management Processor Functionality |
|
|
|||||||||||||||||||||||||
|
|
| System Console Configurations | The HP Integrity rx3600's integrated Management
Processor Card provides six methods for console connections.
|
| | |
| Internal Disk and Media Drives |
|
|
| |
| HP Integrity rx3600 Trusted Platform Module | The
rx3600 has an accessory option for an embedded security chip - the Trusted Platforms
Module (TPM) - product number AB404A. HP-UX Trusted Computing Services (HP-UX
TCS) provides software support for the TPM when running HP-UX 11i v2. By providing
a low-cost embedded security chip option (known as a Trusted Platform Module)
in its zx2-based Integrity servers (rx2660, rx3600, and rx6600), HP has established
a foundation for strong protection of sensitive information - including cryptographic
keys. Built around industry standards, the Trusted Platform Module (TPM) provides
a basis for key storage by securely generating and storing cryptographic keys.
HP-UX 11i TCS takes this a step further by providing the necessary infrastructure
for managing the TPM, as well as integrating it into select features such as HP-UX
Encrypted Volumes and File Systems (EVFS). Using HP-UX TCS with EVFS: Using HP-UX TCS to make the unattended boot capability of EVFS more secure is an important example of how HP-UX TCS can be integrated with other applications to enhance security. For more information see the "Protecting EVFS Keys with HP-UX TCS" chapter in the "HP-UX Trusted Computing Services Administrators Guide" available in the HP-UX Trusted Computing Services section at: http://docs.hp.com/en/internet.html Please note that HP-UX 11iTCS requires:
To download TCS and EVFS, please see the HP-UX Software Depot web page at: http://software.hp.com |
| | |
| HP Integrity rx3600 Power Subsystem |
The HP Integrity rx3600 provides a high level of integrated power protection:
The HP Integrity rx3600 supports a second hot swap power supply for N+1 protection. One supply is shipped as a standard part of every system and is required for correct operation. The hot swap design allows for the online replacement of a power supply when N+1=2 supplies are configured in the server. The HP Integrity rx3600 provides an independent power input receptacle for each power supply. The independent design provides protection against losing the connection from a power cord or breaker. The HP Integrity rx3600 power cords should always be plugged into separate breakers when possible. |
|
|
Technical Specifications
| Server model number | rx3600 | ||
| | |||
| Server product numbers | Two processor/four core capable HP Integrity rx3600 base system with one dual core processor module |
AB463A
|
| Configure with one 1.6 GHz/18 MB dual core processor module |
AB463A#160
|
|
| Configure with one 1.66 GHz/18 MB dual core 9140M processor modules |
AB463A#260
|
|
| Base system includes one power supply (second supply can be added for redundancy) and a 2 port 10/100/1000 GbE PCI-X card (supports Wake On LAN) in one core I/O slot. Must select core I/O storage controller, I/O backplane, memory carrier board option, and memory (minimum 2 GB). | ||
| Two processor/four core capable HP Integrity rx3600 base system with two dual core processor modules |
AB596A
|
|
| Configure with two 1.6 GHz/18 MB dual core processor modules |
AB596A#160
|
|
| Configure with two 1.66 GHz/18 MB dual core 9140M processor modules |
AB596A#260
|
|
| Base system includes one power supply (second supply can be added for redundancy) and a 2 port 10/100/1000 GbE PCI-X card (supports Wake On LAN) in one core I/O slot. Must select core I/O storage controller, I/O backplane, memory carrier board option, and memory (minimum 2 GB). | ||
| Server Form Factor (Required - must choose either Field Rack Kit, or Factory Rack Integration, or Optional Stand Alone mount) | ||
| Please refer to the HP 10000 Series G2 Rack Best Practices Guide for information on rack deployment, stabilization and transportation. (http://www.HP.com/go/rackandpower) | ||
| Universal Rack Kit |
AD053A
|
|
| Field Rack Kit Includes rack slides and cable management arm |
AD053A#B01
|
|
| Factory Rack Integration For factory rack integration, a rack cabinet must appear in the same section of the order. The slides and cable management arm will be installed with the server in the rack cabinet when factory rack integration is ordered. |
AD053A#0D1
|
|
| Optional Stand-Alone Pedestal
Form Factor NOTE: Will not be factory configured, but will be shipped in the system box for field installation only. |
AD054A#B01
|
|
| NOTE: Two power cords are shipped with each system; one that connects the system to the rack PDU and one that enables direct connection to a wall socket. The cord that connects the system power supply to the PDU has an IEC 19 end, which plugs into the system power supply's IEC 20 socket, and an IEC 20 end, which plugs into the PDU's IEC 19 socket. The localized cord that connects the system power supply directly to the wall socket has an IEC 19 end, which plugs into the system power supply's IEC 20 socket, and a country specific end, which plugs into the wall socket. This localized cord is included at the distribution site. | ||
|
|
||
| Supported Processors for Field Upgrades | 1.66 GHz Dual core Intel Itanium 9140M Processor (AD391A) | |
| Cache-On chip Level 1 | 32 KB | |
| Cache-On chip Level 2 | 1 MB Instruction/256 KB Data (per core) | |
| Cache-On chip Level 3 | 18 MB (9 MB per core) | |
| Floating point Coprocessor included | Yes | |
| 1.42 GHz Dual core Intel Itanium 9120N Processor (AD390A) | ||
| Cache-On chip Level 1 | 32 KB | |
| Cache-On chip Level 2 | 1 MB Instruction/256 KB Data (per core) | |
| Cache-On chip Level 3 | 12 MB (6 MB per core) | |
| Floating point Coprocessor included | Yes | |
|
|
||
| System Memory | Minimum memory | 2 GB |
| Maximum memory capacity | 192 GB | |
|
|
||
| Internal Disks | Maximum disk mechanisms | 8 |
| Maximum disk capacity | 2,000 GB | |
|
|
||
| Standard Integrated I/O | Serial Attached SCSI (SAS) Please see specific system offerings for details |
8 ports |
| 10/100/1000Base T (RJ 45 connector) | 2 ports | |
| RS 232 serial ports | 2 | |
| 10/100Base T management port
(RJ 45 connector) |
1 | |
| USB (2.0) Ports | 1 front/2 rear | |
| VGA | Optional for HP UX, Linux, OpenVMS. Required for Windows. |
|
|
|
||
| I/O
Buses and Slots (Must select 1 only) | I/O Backplane Option | AD295A |
| PCI-X 2.0 Backplane | AD295A#100 | |
| Available I/O slots | 8 | |
| Two 266 MHz, 64 bit slots, each on its own dedicated PCI-X bus | ||
| Two 133 MHz, 64 bit slots, each on its own dedicated PCI-X bus | ||
| Four 66 MHz, 64 bit slots distributed on 2 PCI-X buses; 2 slots per bus | ||
| PCI-Express/PCI-X Backplane | AD295A#300 | |
| Available I/O Slots | 8 | |
| Two x8 PCI-Express slots one one 1.3-GB/s bus | ||
| Two x8 PCI-Express slots, each on its own dedicated 2.6-GB/s bus | ||
| Two PCI-X 133-MHz, 64-bit slots, each on its own dedicated bus | ||
| Two PCI-X 66-MHz, 64-bit slots distributed on 1 PCI-X bus | ||
|
| ||
| Maximum I/O Cards (See supported I/O table for product specifics) |
Additional Interface Cards | 8 |
|
|
||
| Electrical Characteristics | AC Input power | 100-240V 50/60 Hz |
| Hot swap Power supplies | 1 included, 2nd for N+1 | |
| Redundant AC power inputs | 1 included, 2nd for N+1 | |
| Maximum input current at 100V | 15 A | |
| Typical power dissipation | 685 Watts | |
| Maximum power dissipation | 1,095 Watts | |
| Power factor at full load | 0.95 or higher | |
| Typical Heat dissipation (BTUs/hour) | 2,337 | |
| Maximum Heat dissipation (BTUs/hour) | 3,736 | |
|
|
||
| Site Preparation | Site planning and installation included NOTE: System is customer installable. |
No |
| Rack system depth | 27.4 in (696 mm) | |
| Rack system width | 17.32 in (440 mm) | |
| Rack system height (EIA/mm) | 178 mm/6.8 in/4 U | |
| Rack system weight maximum (kg/lbs) | 45 kg/99 lbs | |
| Pedestal system depth | 696mm/27.4 | |
| Pedestal system width | 369mm/14.5 in | |
| Pedestal system height | 512mm/20.2 in | |
| Rack weight maximum (kg/lbs) | 52 kg/114 lbs | |
|
|
||
| Environmental Characteristics | Acoustics (operator/bystander)
at 77° F (25° C) |
<6.9 Bels LwA |
| Operating Temperature (up to 5000 ft/1524 m)* |
41° to 95° F (5° to 35° C) | |
| Max. rate of temperature change, operating | 30 per hour | |
| Non-operating Temperature | 5° to 35° F (-40° to 70° C) | |
| Maximum rate of temperature
change, non operating |
20° per hour | |
| Operating relative humidity | 15% to 80% RH non-condensing | |
| Non-operating relative humidity | 5% to 95% non-condensing | |
| Operating altitude above sea level | 3000 m (10,000 ft) max. | |
| Non-operating altitude above sea level | 4600 m (15,000 ft) max. | |
| *
If the N+1 power supply is ordered standalone the power supply will
ship with two cords; one that connects the system to the rack PDU and one
that enables direct connection to a wall socket. The cord that connects
the system power supply to the PDU has an IEC 19 end, which plugs into the
system power supply's IEC 20 socket, and an IEC 20 end, which plugs into
the PDU's IEC 19 socket. The localized cord that connects the system power
supply directly to the wall socket has an IEC 19 end, which plugs into the
system power supply's IEC 20 socket, and a country specific end, which plugs
into the wall socket. This localized cord is included at the distribution
site. If the N+1 power supply is ordered with the server, the additional cords will be included. |
||
|
|
||
| Regulatory Compliance | RMN | RSVLA-0404 |
| Electromagnetic interference | Complies with FCC Rules and Regulations,
Part 15 as a Class A digital device. Manufacturer's Declaration to EN55022
Level A, VCCI Registered, Class A, Korea RLL. |
|
| Safety | UL Listed, CSA Certified, TUV GS Mark compliant with EN 60950 and EN 41003 | |
| More detailed regulatory documents and certifications | http://docs.hp.com/en/hw.html | |
|
|
||
| © Copyright 2009 Hewlett-Packard
Development Company, L.P.
The information contained herein is subject to change without notice. Intel and Itanium are registered trademarks or trademarks of Intel Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |