contents
 Overview      Standard Features      Configuration      Technical Specifications line.gif (50 bytes)

Overview

HP Integrity rx6600 Server

 

HP Integrity rx6600 System Overview (Interior View)
1. Recessed Carrying Handles 3. 8 Hot Plug PCI-X 10 Slots (2 @ 266 MHz)
2. Redundant Bulk Power 4. Hot Swap Fans
HP Integrity rx6600
1. 7U Chassis 3. 4 Clamshell CPU Sockets
2. 16 SAS HDDs 4. 48 DDR2 DIMM Slots
contents
 Overview      Standard Features      Configuration      Technical Specifications line.gif (50 bytes)

Standard Features

Minimum System
  • One 64-bit dual-core Intel Itanium 2 processor; either 1.6-GHz/24 MB cache, or 1.6 GHz/18 MB cache, or 1.4 GHz/12 MB cache; or 1.6 GHz/24 MB 9150N processor, or 1.6 GHz/18 MB 9140N processor, or 1.4 GHz/12 MB 9120N processor
  • One I/O backplane. Either PCI-X 2.0 backplane with 8 available slots or PCI-Express backplane with 8 available slots
  • 2-GB PC2 4200 ECC×4 Single Rank Registered DDR2 SDRAMs (4×512MB DIMMs)
  • 24 DIMM slots (1×24 DIMM slot memory carrier board)
  • One hot swap power supply

Maximum Server Capacities
  • Four dual core 64 bit Intel Itanium 2 processors; either 1.6 GHz/24 MB cache, or 1.6 GHz/18 MB cache, or 1.4 GHz/12 MB cache; or 1.6 GHz/24 MB 9150N processor, or 1.6 GHz/18 MB 9140N processor, or 1.4 GHz/12 MB 9120N processor
  • One I/O backplane. Either PCI-X 2.0 backplane with 8 available slots or PCI-Express backplane with 8 available slots
  • 384 GB PC2 4200 ECC×4 Single Rank Registered DDR2 SDRAMs (24×8 GB DIMMs)
  • 48 DIMM slots (2×24 DIMM slot memory carrier boards)
  • Sixteen Serial Attached SCSI (SAS) disk drives
  • Two hot swap power supplies (two supplies enables redundancy)

Standard System Features
  • Operating System support: HP UX 11i version 2 June 2006 Update, HP UX 11i v3, Linux RHEL AS 4 U4 and SLES 10, OpenVMS V8.3 or higher for Integrity Servers and Microsoft Windows Server 2008 for Itanium-based Systems, and Microsoft SQL Server 2005 and SQL Server 2008
  • Choice of core storage card.
    For HP-UX and OpenVMS-based systems: Must select one of two choices: PCI-X 8 port Serial Attached SCSI (SAS) host bus adapter or PCI-Express 8-port Smart Array (P400) Serial Attached SCSI Controller:
    1. The PCI-X 8-port Serial Attached SCSI (SAS) host bus adapter: Card will be installed in reserved core PCI-X I/O slot #1. This card supports up to two internal RAID 1 volumes (2×2 HDDs) and a disk for global hot spare, for a maximum of five disks in RAIDed arrays for HP UX and OpenVMS. The additional three drives (of the maximum of eight drives supported) can be accessed normally, but not configured for RAID. Factory set up of RAID 1 configurations is supported. When a second SAS Controller is required to support disks 9 through 16, it cannot be factory configured for RAID (unless it is done through Factory Express). For customer/field configured RAID arrays, the same limitations (two RAID 1 arrays and one global hotspare) exist. The additional three HDDs (14 through 16) can be accessed normally, but not configured for RAID. Please see rx6600 Ordering Guide for factory configuration details.
  • NOTE: MirrorDisk/UX is available for SW Mirroring on all HDDs in HP UX based systems and HP Volume Shadowing (software Raid 1) for HDDs in OpenVMS-based systems.
    2. PCI-Express 8-port Smart Array (P400) Serial Attached SCSI Controller: Requires PCI-Express Backplane (AD296A#300); card will be installed in public slot #3, leaving 3 available PCI-Express slots and 4 available PCI-X slots. This card supports internal RAID-1, 5 and 6 configurations. RAID-1 requires a minimum of two identical HDDs, RAID-5 requires a minimum of three identical HDDs, and RAID-6 requires a minimum of four identical HDDs. When a second core PCI-Express P400 RAID controller is required to support disks 9 through 16, it will be installed in slot #4, leaving two available PCI-Express slots and four available PCI-X slots. Second core controller cannot be factory configured for RAID (unless it is done through Factory Express). Please see rx6600 Ordering Guide for factory configuration details.
  • NOTE: PCIe Generation 2 cards are NOT supported in slots 3 and 4 of the AD296A#300 PCIe I/O Backplane.
    For Windows and Linux based systems: Must select one of three choices: PCI-X 8 port Smart Array (P600) Serial Attached SCSI (SAS) controller, or PCI-Express 8-port Smart Array (P400) Serial Attached SCSI Controller, or PCI-Express 16-port Smart Array (P800) Serial Attached SCSI Controller.
    1. PCI-X 8-port Smart Array (P600) Serial Attached SCSI (SAS) controller:
    Card will be installed in reserved core PCI-X I/O slot #1. Supports internal RAID 1, 5 and 6 configurations. RAID 1 requires two identical HDDs, RAID 5 requires three identical HDDs, and
    RAID 6 requires four identical HDDs. Factory set up of RAID 1, 5 and 6 configurations with Smart Array SAS controller is also supported. When a second SAS Controller is required to support disks 9 through 16, it cannot be factory configured for RAID (unless it is done through Factory Express) . For customer/field configured RAID arrays, all eight HDDs (9 through 16) can be configured for RAID levels 1, 5 and 6 in any combination. Please see rx6600 Ordering Guide for details.
    2. PCI-Express 8-port Smart Array (P400) Serial Attached SCSI (SAS) controller.
    Requires PCI-Express Backplane (AD296A#300); card will be installed in public slot #3, leaving 3 available PCI-Express slots and 4 available PCI-X slots. This card supports internal RAID-1, 5 and 6 configurations. RAID-1 requires a minimum of two identical HDDs, RAID-5 requires a minimum of three identical HDDs, and RAID-6 requires a minimum of four identical HDDs. When a second core PCI-Express P400 RAID controller is required to support disks 9 through 16, it will be installed in slot #4, leaving two available PCI-Express slots and four available PCI-X slots. Second core controller cannot be factory configured for RAID (unless it is done throughFactory Express). Please see rx6600 Ordering Guide for factory configuration details.
    3. PCI-Express 16-port Smart Array (P800) Serial Attached SCSI (SAS) controller:
    Requires PCI-Express Backplane (AD296A#200); card will be installed in public slot #3, leaving 3 available PCI-Express slots and 4 available PCI-X slots. This card supports internal and external RAID-1, 5 and 6 configurations. RAID-1 requires a minimum of two identical HDDs, RAID-5 requires a minimum of three identical HDDs, and RAID-6 requires a minimum of four identical HDDs. When a second core PCI-Express P800 RAID controller is required to support disks 9 through 16, it will be installed in slot #4, leaving two available PCI-Express slots and four available PCI-X slots. Second core controller cannot be factory configured for RAID (unless it is done through Factory Express). Please see rx6600 Ordering Guide for factory configuration details.
  • NOTE: PCIe Generation 2 cards are NOT supported in slots 3 and 4 of the AD296A#300 PCIe I/O Backplane (Legacy).
  • Core PCI-X dual port 10/100/1000Base TX LAN (with auto speed sensing; RJ 45 connector, Wake On LAN support)
  • Integrated iLO2 Management Processor for remote management and HA monitoring
  • Telnet and web console via 10/100Base TX management LAN (RJ 45 connector)
  • Two RS 232 serial ports, one for console from the integrated management processor and one from the processor dependent hardware bus (PDH)
  • Factory integration of processors, memory, disk drives, removable media, I/O cards, and HP Universal 10000 G2 series racks.
  • Rackmountable into 19 inch cabinets-HP Universal 10000 G2 series as well as many third party racks, including field integration into existing HP System E racks
  • Optional stand alone pedestal mount, field installation only.
  • Three year warranty with next business day on site.

High Availability
  • N+1 Hot swap cooling
  • One Hot swap power supply-optional second power supply for N+1 protection
  • Hot Plug PCI X I/O slots (Note: Some I/O cards do not support hot plugging. Please see Supported I/O card Table 3 this chapter for details.)
  • On line memory page deallocation
  • ECC protected DDR2 memory
  • Memory double chip spare to overcome single DRAM chip failures
  • Dynamic Processor resilience and deallocation
  • UPS power management
  • Hot Plug internal disks
  • Internal RAID support. See Standard Systems Features on previous page and rx6600 Ordering Guide for various levels of RAID support.
  • Journal file system with HP UX
  • Auto reboot
  • HP Serviceguard for HP UX
  • HP Serviceguard Extension for RAC for HP UX
  • HP Serviceguard Extension for SAP for HP UX
  • Serviceguard Manager for HP UX and Linux Clusters
  • HP Event Monitoring Service
  • HA Monitors for HP UX
  • HA Toolkits for HP UX and Linux
  • HP Mirrordisk/UX
  • Extended Campus Cluster, HP Metrocluster, and HP Continentalclusters for HP UX
  • HP OpenVMS clusters
  • HP Volume Shadowing for OpenVMS
  • HP RMS Journaling for OpenVMS
  • HP System Insight Manager (SIM) for proactive fault management
  • Microsoft Windows Server 2008 for Itanium-based Systems, and Microsoft SQL Server 2005 and SQL Server 2008
  • HP StorageWorks Software for HP Integrity Servers running Windows Server 2003 Enterprise Edition. Includes Cluster Extension XP and EVA, Continuous Access, Business Copy and SQL Server Fast Recovery
  • HP StorageWorks Cluster Extension XP for Linux

Security
  • Separate LAN for system management
  • Password protection on console port
  • Disablement of remote console ports
  • SSL encryption on web console

Manageability - Deploy

  • HP Ignite UX for installation and deployment of the operating system
  • HP Software Distributor UX for software and patch management
  • HP Integrity Essentials Foundation Pack for Linux
  • HP Integrity Essentials Foundation Pack for Windows including Smart Setup CD for easy server setup and configuration
Manageability - Monitor
  • Built in Integrity iLO 2 Management Processor for comprehensive remote server management of HP UX, Linux, Windows and OpenVMS
  • HP Servicecontrol suite for HP UX servers including tools for system administration, asset management, and fault management
  • HP UX kernel configuration for easy, dynamic kernel parameter changes
  • HP System Insight Manager (SIM)
Manageability - Optimize
  • Process Resource Manager for HP UX resource management
  • HP UX Workload Manager for HP UX workload management based upon service level objectives
  • HP OpenView GlancePlus Pack
  • HP Intelligent Networking Pack for Windows
  • HP Performance Management Pack for Windows
  • Windows System Resource Manager (included with each copy of Windows Server 2003 Enterprise Edition)*

*Please note that the last order date for Windows Server 2003 is Feb 28, 2009. However, Microsoft provides downgrade rights for the customers to purchase WS 2008 downgrade from Windows Server 2008 to Windows Server 2003. Customers can continue to buy WS 2003 license directly from Microsoft.

contents
 Overview      Standard Features      Configuration      Technical Specifications line.gif (50 bytes)

Configuration

Processor Configuration The HP Integrity rx6600 is a symmetrical multiprocessing (SMP) server supporting up to four high performance 64 bit dual core Intel Itanium processors. The dual core Intel Itanium processor supports hyper threading. Each core of the processor supports two threads.

Processor Details

Dual core Intel Itanium processors:

  • 1.6 GHz with 24 MB Level 3 Cache, 12 MB per core processor (Upgrade Only)
  • 1.6 GHz with 24 MB Level 3 Cache, 12 MB per core 9150N processor
  • 1.6 GHz with 18 MB Level 3 Cache, 9 MB per core processor (Upgrade Only)
  • 1.6 GHz with 18 MB Level 3 Cache, 9 MB per core 9140N processor
  • 1.4 GHz with 12 MB Level 3 Cache, 6 MB per core processor (Upgrade Only)
  • 1.4 GHz with 12 MB Level 3 Cache, 6 MB per core 9120N processor


All processors support:

  • Level 2 Cache: 1 MB Instruction/256 KB Data per core
  • Level 1 Cache: 32 KB
  • Four threads (two threads per core)
  • Single bit cache error correction
  • 50 bit physical addressing
  • 64 bit virtual addressing
  • 4 GB maximum page size

Processor Configuration Rules
  • Processors can be installed one at a time
  • Processors must be installed in the following sequence: 0, 1, 2, and 3
  • Different speed and different cache size processors cannot be mixed in the same system

Memory Configuration

The HP Integrity rx6600 supports double data rate (DDR2) synchronous dynamic random access memory (SDRAM) DIMMs with ECC and double chip spare protection. The HP Integrity rx6600 can be ordered with one of the following two memory carrier boards:

  • AD126A-Supports from 2 GB minimum to 96 GB maximum memory; 8.5 GB/s memory bandwidth. The AD126A can be replaced with the AD127A to increase maximum memory beyond 96-GB and to a maximum of 192-GB, or to increase memory bandwidth to 17.0 GB/s. Please note, there is no return credit for the AD126A.
  • AD127A-Supports from 2 GB minimum to 384 GB maximum memory; 17.0 GB/s memory bandwidth.
Memory Loading Rules
  • Memory must be installed in groups of four DIMMs, also known as quads
  • Each quad must consist of equal density DIMMs
  • Memory can be ordered in quads of 2 GB (4×512MB), 4 GB (4×1GB), 8 GB (4×2GB), 16 GB (4×4GB), or 32 GB (4x8GB)
  • Minimum memory is 2 GB (4×512MB)
  • Maximum memory is 384 GB, using twelve 16 GB memory quads in memory carrier option AD127A
  • Memory must be loaded in the order depicted on the memory carrier board.
  • Arrange DIMMs so that the quads with the largest capacity are in the lowest numbered slots.
  • For best performance, all DIMM slots on both memory carrier boards should be populated with the same size DIMM.
Memory Options
Description Product Number
4-GB chip spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×1GB DIMMs) AB564A
8-GB chip spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×2GB DIMMs) AB565A
16-GB chip spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×4GB DIMMs) AB566A
32-GB chip spare PC2 4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×8GB DIMMs) AH405A
Server Form Factor and Rack Configuration The HP Integrity rx6600 is a 7U rack optimized server. It is supported in HP 10000 G2 series cabinets. For factory integration order AD053A with 0D1 feature code. Sliding mounts and a cable management arm will be installed with the server in a factory integrated rack.

The HP Integrity rx6600 can be installed in the field with the Field Rack Kit (AD053A with B01 feature code). This field kit contains the slide mounts, cable management arm, and all other hardware needed to mount an rx6600 into a 19 inch cabinet.

Refer to the 10000 G2 Series Rack Best Practices Guide for information on rack deployment, stabilization and transportation. Go to: http://www.hp.com/go/rackandpower for more information.

The rx6600 is also available in a stand-alone, pedestal form factor (AD308A). Kit will be shipped in a separate box for field installation only.


I/O Architecture

The HP Integrity rx6600 supports two I/O backplane options in order to provide maximum flexibility, I/O card availability, performance, scalability and reliability. The two options are a PCI-X 2.0 Backplane (AD296A#100) or a PCI-Express Backplane option (AD296A#300). Only one backplane per system is supported.

PCI-X 2.0 Backplane:
This backplane provides ten PCI X I/O slots, two of which are reserved for Core I/O cards, and eight of which are available for I/O card expansion. The Core I/O slots will always be filled with either an HP PCI X 8 Internal Port Serial Attached SCSI (SAS) host bus adapter (for HP UX and OVMS systems) or an HP PCI X Smart Array (P600) 8 Internal Port Serial Attached SCSI (SAS) card (for Windows and Linux systems) (slot #1) and a PCI X dual port 10/100/1000Base TX LAN adapter (slot #2).

Each port of a Serial Attached SCSI card can be connected to a Serial Attached SCSI hard disk drive. When more than eight hard disk drives are required, a second HP PCI-X 8 port SAS card must be ordered. This second SAS card will be installed in the second core I/O slot, and the PCI-X dual port 10/100/1000Base TX LAN adapter will be moved out to a standard I/O slot. Note that when the LAN adapter is moved out to a standard I/O slot, Wake On LAN is not supported.

HP-UX and OpenVMS based systems with PCI-X 2.0 Backplane:
Must choose the HP PCI-X 8 Internal Port Serial Attached SCSI host bus adapter for Core I/O controller (AB036B#006 or AB036B#106). If factory configured RAID is not desired, select Option Code 006. If factory configured RAID-1 is desired, select Option Code 106. RAID-1 only is supported on the HP PCI-X 8 Internal Port SAS host bus adapter. When selecting Option Code 106, a minimum of 2 HDD's of the same size and speed are required. A maximum of two internal RAID 1 volumes (2×2 HDDs) and a disk for global hot spare, for a maximum of five disks in RAIDed arrays is supported. The additional three drives (of the maximum of eight drives supported on the controller) can be accessed normally, but not configured for RAID. When from 9 to 16 HDD's are ordered, a second SAS Controller is required to support disks 9 through 16. The second controller cannot be factory configured for RAID (unless it is done through Factory Express). For customer/field configured RAID arrays, the same limitations (two RAID 1 arrays and one global hot spare) exist. The additional three HDDs (14 through 16) can be accessed normally, but not configured for RAID. Please see rx6600 Ordering Guide for factory configuration details. Please note that MirrorDisk/UX is available for SW Mirroring on all HDDs in HP-UX based systems and HP Volume Shadowing (software Raid 1) for HDDs in OpenVMS-based systems.

Windows and Linux based systems with PCI-X 2.0 Backplane:
Must choose the HP PCI-X 8 port Smart Array (P600) Serial Attached SCSI (SAS) controller for Core I/O controller (AB036B#100, or AB036B#500, or AB036B#510). Option 100 provides for factory configuration of RAID-1 (requires a minimum of 2 HDDs). Option 500 provides for factory configuration of RAID-5 (requires a minimum of 3 HDDs). Option 510 provides for factory configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs must be the same size and speed. When from 9 to 16 HDDs are ordered, a second SAS Controller is required to support disks 9 through 16. The second controller cannot be factory configured for RAID (unless it is done through Factory Express). Please see rx6600 Ordering Guide for details.

Remaining Eight (non-Core I/O) slots:
The two slots (#3 and #4) next to the Core I/O slots have their own dedicated 64 bit 266 MHz PCI X bus and their own independent 2.1 GB/s I/O channel. These slots should be used for high performance PCI X cards, such as clustering interconnects or multi port storage adapters. The next two slots (slots #5 and #6) each have their own dedicated 64 bit 133 MHz PCI X bus and their own independent 1.1 GB/s I/O channel. The independent buses and I/O channels provide improved performance and error containment. Independence protects each I/O card from bus hangs or extended latencies due to the failure or high bandwidth demands of other I/O cards. Independence also ensures that each I/O card can achieve maximum throughput.

The remaining four slots (#7 through #10) share two 64 bit 66 MHz PCI X buses, with two slots allocated to each bus. Each pair of slots shares a 0.5 GB/s I/O channel.

NOTE: Hot plug operations are not supported with the Linux or OpenVMS operating systems or in the core I/O slots with any operating system.

All I/O slots are keyed for I/O cards with 3.3V signaling. Cards that use 5V signaling are not supported in the HP Integrity rx6600.

PCI-Express Backplane:
This backplane also provides ten I/O slots. There are two PCI X Core I/O slots; one PCI X Core I/O slot will always have a PCI X dual port 10/100/1000Base TX LAN adapter (slot #2), unless a second storage controller is required, in which case the second controller is configured in slot #2 and the LAN card is moved out to public slot #10, and one PCI X Core I/O slot is provided in the case that the HP PCI X 8 Internal Port Serial Attached SCSI (SAS) host bus adapter is chosen when ordering an HP UX or OpenVMS based system, or if an HP PCI X Smart Array (P600) 8 Internal Port Serial Attached SCSI (SAS) card is chosen (slot #1) when ordering a Windows or Linux based system. If a PCI Express 8 port Smart Array (P400, supports only internal connection to SAS disks) Serial Attached SCSI controller (supported with HP UX, OpenVMS, Windows, and Linux) is chosen, or if a PCI Express 16 port (8 internal ports and 8 external ports) Smart Array (P800) Serial Attached SCSI controller (for Windows and Linux only, also supports connection to external SAS disks) is chosen, the PCI X Core I/O slot remains empty and the PCI Express controller is installed in slot #3.

Each port of a Serial Attached SCSI card can be connected to a Serial Attached SCSI hard disk drive. When more than eight hard disk drives are required, a second 8 port Serial Attached SCSI card must be ordered. If a PCI-X card is chosen, it will be installed in the reserved PCI-X core I/O slot. If a PCI-Express card is chosen, it will be installed in slot #4.

HP-UX and OpenVMS based systems with PCI-Express Backplane:
These systems have the two choices for Core I/O controller; the HP PCI-X 8 Internal Port Serial Attached SCSI host bus adapter or the HP PCI-Express 8 Internal Port Smart Array (P400) Serial Attached SCSI controller.

  1. HP PCI-X 8 Internal Port Serial Attached SCSI host bus adapter (AB036B#006 or AB036B#106). If factory configured RAID is not desired, select Option Code 006. If factory configured RAID-1 is desired, select Option Code 106. RAID-1 only is supported on the HP PCI-X 8 Internal Port SAS host bus adapter. When selecting Option Code 106, a minimum of 2 HDD's of the same size and speed are required. A maximum of two internal RAID 1 volumes (2×2 HDDs) and a disk for global hot spare, for a maximum of five disks in RAIDed arrays is supported. The additional three drives (of the maximum of eight drives supported on the controller) can be accessed normally, but not configured for RAID. When from 9 to 16 HDD's are ordered, a second SAS Controller is required to support disks 9 through 16. The second controller cannot be factory configured for RAID (unless it is done through Factory Express). For customer/field configured RAID arrays, the same limitations (two RAID 1 arrays and one global hotspare) exist. The additional three HDDs (14 through 16) can be accessed normally, but not configured for RAID. Please see rx6600 Ordering Guide for factory configuration details. Please note that MirrorDisk/UX is available for SW Mirroring on all HDDs in HP-UX based systems and HP Volume Shadowing (software Raid 1) for HDDs in OpenVMS-based systems.
  2. PCI-Express 8-port Smart Array (P400) Serial Attached SCSI Controller (AB036B#130, or AB036B#530, or AB036B#540). Requires PCI-Express Backplane (AD296A#300). Option 130 provides for factory configuration of RAID-1 (requires a minimum of 2 HDDs). Option 530 provides for factory configuration of RAID-5 (requires a minimum of 3 HDDs). Option 540 provides for factory configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs must be the same size and speed. When from 9 to 16 HDDs are ordered, a second SAS Controller is required to support disks 9 through 16. The second controller cannot be factory configured for RAID (unless it is done through Factory Express). Please see rx6600 Ordering Guide for details.

NOTE: MirrorDisk/UX is available for SW Mirroring on all HDDs in HP UX based systems and HP Volume Shadowing (software Raid 1) for HDDs in OpenVMS-based systems.

Windows and Linux based systems with PCI-Express Backplane:
These system have three choices for Core I/O controller; the PCI-X 8 Internal Port Smart Array (P600) Serial Attached SCSI controller, or the PCI-Express 8 Internal Port Smart Array (P400) Serial Attached SCSI controller, or the PCI-Express 16-port (8 Internal/8 External) Smart Array (P800) Serial Attached SCSI controller.

  1. HP PCI-X 8 port Smart Array (P600) Serial Attached SCSI controller (AB036B#100, or AB036B#500, or AB036B#510). Option 100 provides for factory configuration of RAID-1 (requires a minimum of 2 HDDs). Option 500 provides for factory configuration of RAID-5 (requires a minimum of 3 HDDs). Option 510 provides for factory configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs must be the same size and speed. When from 9 to 16 HDDs are ordered, a second SAS Controller is required to support disks 9 through 16. The second controller cannot be factory configured for RAID (unless it is done through Factory Express) . Please see rx6600 Ordering Guide for details.
  2. PCI-Express 8-port Smart Array (P400) Serial Attached SCSI Controller (AB036B#130, or AB036B#530, or AB036B#540). Requires PCI-Express Backplane (AD296A#300). Option 130 provides for factory configuration of RAID-1 (requires a minimum of 2 HDDs). Option 530 provides for factory configuration of RAID-5 (requires a minimum of 3 HDDs). Option 540 provides for factory configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs must be the same size and speed. When from 9 to 16 HDDs are ordered, a second SAS Controller is required to support disks 9 through 16. The second controller cannot be factory configured for RAID (unless it is done through Factory Express) . Please see rx6600 Ordering Guide for details.
  3. PCI-Express 16-port Smart Array (P800) Serial Attached SCSI Controller (AB036B#150, or AB036B#550, or AB036B#560). Requires PCI-Express Backplane (AD296A#300). Option 150 provides for factory configuration of RAID-1 (requires a minimum of 2 HDDs). Option 550 provides for factory configuration of RAID-5 (requires a minimum of 3 HDDs). Option 560 provides for factory configuration of RAID-6 (requires a minimum of 4 HDDs). All HDDs must be the same size and speed. When from 9 to 16 HDDs are ordered, a second SAS Controller is required to support disks 9 through 16. The second controller cannot be factory configured for RAID (unless it is done through Factory Express) . Please see rx6600 Ordering Guide for details.

Remaining Eight (non-Core I/O) slots:
The two slots (#3 and #4) next to the Core I/O slots share a PCI-Express x8 1.3-GB/s I/O channel. The next two slots (slots #5 and #6) each have their own PCI-Express x8 2.6-GB/s I/O channel. The independent I/O channels provide improved performance and error containment. Independence protects each I/O card from bus hangs or extended latencies due to the failure or high bandwidth demands of other I/O cards. Independence also ensures that each I/O card can achieve maximum throughput. These slots should be used for high performance PCI X cards, such as clustering interconnects or multi port storage adapters.

The remaining four slots (#7 through #10) are PCI-X slots. Slots #7 and #8 each have their own dedicated 64 bit 133 MHz PCI-X channel; slot #7 is 1.1 GB/s and slot #8 is 0.5 GB/s. Slots #9 and #10 share a 64-bit 66-MHz PCI-X 0.5 GB/s I/O channel.

NOTE: Hot plug operations are not supported with the Linux or OpenVMS operating systems or in the PCI X Core I/O slots with any operating system. Hot plug operations are not supported for any operating system in slots #3 or #4.

All I/O slots are keyed for I/O cards with 3.3V signaling. Cards that use 5V signaling are not supported in the HP Integrity rx6600.

 
Supported I/O Cards
 
Supported HP-UX I/O Cards
I/O Card
Product Number
PCIe/
PCI-X
Boot Support
Connector Type(s)
Maximum Cards
PCI-X Backplane
Maximum Cards
PCI-Express Backplane
Special Notes
Multi function Cards (Mass Storage/LAN)
HP PCI-X 1 port 4 GB Fibre Channel/1 port 1000Base T Adapter
AD193A
PCI-X
Yes
1 LC, 1 RJ-45
8
4
 
HP PCI-X 2 port 4 GB Fibre Channel/2 port 1000Base T Adapter
AD194A
PCI-X
Yes
2LC, 2 RJ-45
8
4
PCI-X 2 Gb Fibre Channel/1000Base SX
A9782A
PCI-X
Yes
LC
For maximum performance, card should not be installed in a shared slot.
PCI-X 2 port 1000Base T/2 port U320 Multi function Adapter
AB290A
PCI-X
Yes
SCSI - LVD/SE
LAN - RJ-45
6
2
Local Area Network (LAN) Adapters
PCIe 4-Gb Fibre Channel/GbE-T HBA combo
AD221A
PCIe
Yes
0
4
 
PCIe 2-port 4-Gb Fibre Channel/2-port GbE-T HBA combo
AD222A
PCIe
Yes
0
4
 
PCIe 2-port 4-Gb Fibre Channel/2-port GbE-SX HBA combo
AD393A
PCIe
Yes
0
4
  
PCI-X 1 port 1000Base T (gigabit copper)
AD331A
PCI-X
No
RJ-45
8
4
 
PCI-X 2 port 1000Base T
A7012A
PCI-X
Yes
RJ-45
8
4
PCI-X 4 port 1000Base T 1GbE Adapter
AB545A
PCI-X
Yes
RJ-45
8
4
 
PCI-X 1 port 1000Base SX (gigabit fiber)
AD332A
PCI-X
No
Duplex SC
8
4
 
PCI-X 2 port 1000Base SX
A7011A
PCI-X
Yes
Duplex SC
8
4
PCI-X 1 port 10GbE
AB287A
PCI-X
Yes
Duplex LC
4
2
For best performance, recommend at least one processor core per card installed in the system. Each card requires 512 MB of memory. Card cannot be installed in a shared slot.
HP PCIe 2-port 1000Base-T card
AD337A
PCIe
Yes
RJ-45
0
4
HP PCIe 2-port 1000Base-SX card
AD338A
PCIe
Yes
Duplex SC
0
4
 
PCIe 2-port 4X DDR Fast IB HCA
AH304A
PCIe
No
0
4
 
HP PCI-e 10GbE SR card
AD386A
PCIe
Yes
0
4
 
PCIe 4-port HP NC364T Gbit Adapter
AD339A
PCIe
Yes
0
4
 
PCI-X 266-MHz 1 port 10GbE
AD385A
PCI-X
Yes
Duplex LC
4
2
For best performance, recommend at least one processor core per card installed in the system. Each card requires 512 MB of memory. Card cannot be installed in a shared slot.
Fibre Channel Storage Network Adapters Cards
HP PCIe 1-port 4-Gb/s Fibre Channel HBA
AD299A
PCIe
No
LC
0
2
HP PCIe 2-port 4-Gb/s Fibre Channel HBA
AD355A
PCIe
No
LC
0
2
PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel
AB378B
PCI-X
Yes
LC
8
4
 
PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel
AB379B
PCI-X
Yes
LC
8
4
 
PCIe 2 port 4 Gb/s Fibre Channel
AD300A
PCIe
Yes
LC
0
2
 
Fibre Channel Cards
PCI 2 channel Ultra320 SCSI

A7173A

PCI-X
Yes
VHDCI
8
4
 
HP PCIe SC44Ge SAS HBA AH303A PCIe Yes   0 4  
HP PCIe 1-port 8Gb FC SR (Qlogic) HBA AH400A PCIe Yes   0 2 Total of four cards are supported with the AB463-2163A backplane, making slots 3 and 4 possible. Without the new backplane, PCIe Gen2 cards do not function in those slots
HP PCIe 2-port 8Gb FC SR (Qlogic) HBA AH401A PCIe Yes   0 2 Maximum two cards are supported with HP-UX. With OpenVMS and Windows, total of four cards are supported with the AB463 2163A backplane, making slots 3 and 4 possible. Without the new backplane, PCIe Gen2 cards do not function in those slots
RAID Adapters Cards
PCI-X 2 channel Smart Array 6402 Ultra320
A9890A
PCI-X
Yes
VHDCI
6
2
Requires minimum of 512 MB of memory and full length slot
PCI-X 4 channel Smart Array 6404 Ultra320
A9891A
PCI-X
Yes
VHDCI
6
1
Requires minimum of 512 MB of memory and full length slot
PCIe Smart Array P800
AD335A
PCIe
Yes
Mini SAS
0
4
 
Wide Area Network (WAN) Adapters
2 port Programmable Serial Interface (PSI)
X.25/Frame Relay/SDLC
J3525A PCI-X No RS 530, RS 232, V.35, RS 449 or X.21 8 4  
Cluster Interconnect
PCI-X 2 port 4x Fabric (HPC) Adapter AB286C PCI-X No 4x Infiniband Copper 8 4 For maximum performance, card should not be installed in a shared slot. Requires a minimum of 512 MB memory.
PCIe 2 port 4x Fabric (PHC) Adapter AD313A PCIe No 4x Infiniband Copper 0 4  
PCI 8 port Serial MUX Adapter AD278A PCI-X No   8 4  
PCI 64 port Serial MUX Adapter AD279A PCI-X No   8 4  
16 port RS 232 RJ45 Port Module AD280A   No 4 per AD279A N/A N/A AD280A #001 Port Module Power Supply, required on Port Module (3) and Port Module (4) connected to an AD279A 64 port MUX adapter.
16-port RS-232 DB-25 Port Module AD281A   No 4 per AD279A N/A   AD281A #001 Port Module Power Supply, required on Port Module (3) and Port Module (4) connected to an AD279A 64 port MUX adapter.
Graphics Cards
HP 2D PCI-X graphics card AH391A PCI No VGA 2 2 T/P/I: HP UX PCI-x and PCI-x/PCI-e 2/2/2
 
Supported OpenVMS I/O Cards
I/O Card
Product Number
PCIe/
PCI-X
Boot Support
Connector Type(s)
Maximum Cards
PCI-X Backplane
Maximum Cards
PCI-Express Backplane
Special Notes
Combination Cards
HP PCI-X 1 port 4 GB Fibre Channel/1 port 1000Base T Adapter
AD193A
PCI-X
Yes
1 LC, 1 RJ-45
2
2
HP PCI-X 2 port 4 GB Fibre Channel/2 port 1000Base T Adapter
AD194A
PCI-X
Yes
2LC, 2 RJ-45
2
2
PCI-X 2 Gb Fibre Channel/1000Base SX
A9782A
PCI-X
Yes
LC
4
4
For maximum performance, card should not be installed in a shared slot.
PCI-X 2 port 1000Base T/2 port U320 Multi function Adapter
AB290A
PCI-X
Yes
SCSI - LVD/SE
LAN - RJ-45
2
2
Requires full length slot.
Local Area Network (LAN) Adapters 
PCIe 4 Gb Fibre Channel/GbE T HBA combo AD221A PCIe Yes   0 2  
PCIe 2 port 4 Gb Fibre Channel/2 port GbE T HBA combo AD222A PCIe Yes   0 2  
PCIe 2 port 4 Gb Fibre Channel/2 port GbE SX HBA combo AD393A PCIe Yes   0 2  
PCI-X 1 port 1000Base T (gigabit copper)
AD331A
PCI-X
No
RJ-45
8
4
 
PCI-X 2 port 1000Base T
A7012A
PCI-X
No
RJ-45
8
4
 
HP PCI-X 4-Port 1000Base-T Gigabit Adapter
AB545A
PCI-X
Yes
3
3
 
PCI-X 1 port 1000Base SX (gigabit fiber)
AD332A
PCI-X
No
Duplex SC
8
4
  
PCI-X 2 port 1000Base SX
A7011A
PCI-X
No
Duplex SC
8
4
  
PCI-X 1 Port 10GbE
AB287A
PCI-X
No
Duplex LC
2
2
  
HP PCIe 2-port 1000Base-T Card
AD337A
PCIe
Yes
0
4
 
HP PCIe 2-port 1000Base-SX Card AD338A PCIe Yes   0 4  
PCIe 4-port HP NC364T Gbit Adapter AD339A PCIe No   0 4  
PCI-X 266MHz 10GigE SR Card AD385A PCI-X Yes   2 2  
Fibre Channel Storage Network Adapters Cards
HP PCIe 1-port 4-Gb/s Fibre Channel HBA
AD299A
PCIe
No
LC
0
4
HP PCIe 2-port 4-Gb/s Fibre Channel HBA
AD355A
PCIe
No
LC
0
4
PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel
AB378B
PCI-X
Yes
LC
8
4
 
PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel
AB379B
PCI-X
Yes
LC
8
4
 
PCIe 2 port 4 Gb/s Fibre Channel
AD300A
PCIe
Yes
LC
0
4
 
Fibre Channel Cards
PCI 2 channel Ultra320 SCSI
A7173A
PCI-X
Yes
VHDCI
4
4
No On Line Add and Replace support.
HP PCIe SC44Ge SAS HBA AH303A PCIe Yes   0 4  
RAID Adapters Cards
PCI-X 2 channel Smart Array 6402 Ultra320 A9890A PCI-X Yes VHDCI 2 2 Requires minimum of 512 MB of memory and full length slot
PCI-X 2 channel Smart Array 6404 Ultra320 A9891A PCI-X Yes VHDCI 1 1 Requires minimum of 512 MB of memory and full length slot
PCIe Smart Array P800 AD335A PCIe Yes Mini SAS 0 4  
Graphics Cards
HP 2D PCI-X graphics card AH391A PCI No VGA 4 3 RNo OpenVMS factory integration.
AH391A offers 2D graphics support. Support available for OpenVMS 8.3-1h1 and 8.3.
OpenVMS PCI-x 4/4/4, PCI-e 3/3/3
 
Supported Windows I/O Cards

NOTE:
While ordering Windows Server 2008, do not mix differing brands of HBAs (Emulex and Qlogic) within the same server configuration in an MPIO environment.This is to avoid issues which occur when different Fibre Channel HBAs are used within the same server which support different I/O max transfer packet sizes in an MPIO environment. For example, the Emulex Fibre Channel HBAs support a max I/O transfer packet size of 1MB and the Qlogic Fibre Channel HBAs support a max I/O transfer packet size of 2MB. Mixing these two cards in an MPIO configuration can cause the system to hit a BSOD 0X000000D1 with a reference to elxstor.sys

This applies to the following products:
Emulex:
HP StorageWorks single port 8 Gigabit PCI-e FC Emulex HBA (AH402A)
HP StorageWorks dual port 8 Gigabit PCI-e FC Emulex HBA (AH403A)
HP StorageWorks 4 Gb Single Port 64-bit 266 MHz Fibre Channel HBA (AD167A)
HP StorageWorks 4 Gb Dual Port 64-bit 266 MHz Fibre Channel HBA (AD168A)
HP StorageWorks FC2142 PCIe Single Port 4 Gb Fibre Channel adapter (A8002A)
HP StorageWorks FC2242 PCIe Dual Port 4 Gb Fibre Channel adapter (A8003A)

Qlogic
HP StorageWorks single port 8 Gigabit PCI-e FC Qlogic HBA (AH400A)
HP StorageWorks dual port 8 Gigabit PCI-e FC Qlogic HBA (AH401A)
HP StorageWorks 4 Gb Single Port 64-bit 266 MHz Fibre Channel HBA (AB429A)
HP StorageWorks 4 Gb Dual Port 64-bit 266 MHz Fibre Channel HBA (AB379A)
HP StorageWorks 4 Gb Dual Port 64-bit 266 MHz Fibre Channel HBA (AB379B)
HP StorageWorks FC1142 PCIe Single Port 4 Gb Fibre Channel adapter (AE311A)
HP StorageWorks AD300A PCIe Dual Port 4 Gb Fibre Channel adapter (AD300A)

I/O Card
Product Number
PCIe/
PCI-X
Boot Support
Connector Type(s)
Maximum Cards
PCI-X Backplane
Maximum Cards
PCI-Express Backplane
Special Notes
Local Area Network (LAN) Adapters
PCI 2 port Windows/Linux 1000Base TX
A9900A
PCI-X
No
RJ-45
6
4
No On Line Add and Replace support.
HP PCI-X 2-port 1000Base-SX (optical) Gigabit Adapter
A7011A
PCI-X
Yes
6
4
 
PCI-X 1 port 10 GbE
AD144A
PCI-X
Yes
Duplex LC
4
4
Each card requires 512 MB of memory.
Card cannot be installed in a shared slot.
HP PCIe 2-port 1000Base-T card
AD337A
PCIe
Yes
RJ-45
0
4
HP PCIe 2-port 1000Base-SX card
AD338A
PCIe
Yes
Duplex SC
0
4
PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel
AB429A
PCI-X
Yes
LC
6
4
PCI-X 266 MHz 2 channel 4 Gb/s Fibre ChannelAB379BPCI-XYesLC64Replaces AB379A
PCI-X 266 MHz 1 channel 4 Gb/s Fibre ChannelAD167APCI-XYesLC64 
PCI-X 266 MHz 2 channel 4 Gb/s Fibre ChannelAD168APCI-XYesLC64 
PCIe 1 port 4 Gb/s Emulex Fibre ChannelA8002APCIeYesLC04 
PCIe 2 port 4 Gb/s Emulex Fibre ChannelA8003APCIeYesLC04 
PCIe 1 port 4 Gb/s Fibre ChannelAE311APCIeYesLC04 
PCIe 2 port 4 Gb/s Fibre ChannelAD300APCIeYesLC04 
HP PCI X 266 MHz 10GigE SR CardAD385APCI-XYes 44 
Fibre Channel Cards
PCI 2 channel Ultra320 SCSIA7173APCI-XYesVHDCI22 
PCIe Smart Array P500AH226APCIeYesMini SAS04 
PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller (for external storage only)337972-B21PCI-XYesSFF847064A maximum of (4) may be ordered with #0D1, the remaining (2) must be ordered without #0D1
512 MB cache memory upgrade for SA640x and SA P600 controller372538-B21PCI-XN/AN/AN/AN/A 
PCIe Smart Array P800AD335APCIeYesMini SAS04 
HP PCIe 1 port 8 Gb FC SR (Qlogic) HBAAH400APCIeYes 04 
HP PCIe 2 port 8 Gb FC SR (Qlogic) HBAAH401APCIeYes 04 
HP PCIe 1-port 8 Gb FC SR (Emulex) HBAAH402APCIeYes 04 
HP PCIe 2-port 8 Gb FC SR (Emulex) HBAAH403APCIeYes 04 
 
Supported Linux (RHEL 4 U4 and SLES 10) I/O Cards
I/O Card
Product Number
PCIe/
PCI-X
Boot Support
Connector Type(s)
Maximum Cards
PCI-X Backplane
Maximum Cards
PCI-Express Backplane
Special Notes
Local Area Network (LAN) Adapters 
PCI 2 port Windows/Linux 1000Base TX
A9900A
PCI-X
No
RJ-45
8
4
No On Line Add and Replace support.
HP PCI-X 2-port 1000Base-SX (optical) Gigabit Adapter
A7011A
PCI-X
Yes
8
4
HP PCIe 2-port 1000Base-T card
AD337A
PCIe
Yes
RJ-45
0
4
 
HP PCIe 2-port 1000Base-SX cardAD338APCIeYesDuplex SC04 
AD385A - HP PCI-X 266MHz 10GigE SR CardAD385A Yes 22 
Fibre Channel Storage Network Adapters
PCI-X 266 MHz 1 channel 4 Gb/s Fibre ChannelAB429APCI-XYesLC42Qlogic and Emulex HBAs are not supported in the same server.
PCI-X 266 MHz 2 channel 4 Gb/s Fibre ChannelAB379BPCI-XYesLC42Replaces AB379A
PCI-X 266 MHz 1 channel 4 Gb/s Fibre ChannelAD167APCI-XYesLC60Qlogic and Emulex HBAs are not supported in the same server. No On Line Add and Replace support.
PCI-X 266 MHz 2 channel 4 Gb/s Fibre ChannelAD168APCI-XYesLC60Qlogic and Emulex HBAs are not supported in the same server. No On Line Add and Replace support.
PCIe 1 port 4 Gb/s Emulex Fibre ChannelA8002APCIeYesLC04 
PCIe 2 port 4 Gb/s Emulex Fibre ChannelA8003APCIeYesLC04 
PCIe 1 port 4 Gb/s Fibre ChannelAE311APCIeNoLC04 
PCIe 2 port 4 Gb/s Fibre ChannelAD300APCIeYesLC04 
Fibre Channel Cards
PCI 2 channel Ultra320 SCSIA7173APCI-XYesVHDCI44No On Line Add and Replace support.
HP PCIe Smart Array E500 SAS ControllerAH226APCIeYes 04 
HP PCIe SC44Ge SAS HBAAH303APCIeNo 04Connect to external SAS tape drives only.
RAID Adapters Cards
PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller (for external storage only)337972-B21PCI-XYesSFF847044 
512 MB cache memory upgrade for SA640x and SA P600 controller372538-B21PCI-XN/AN/AN/AN/A 
PCIe Smart Array P800AD335APCIeNoMini SAS04 
 
Support Internal Storage Devices Product Number
Device  
Internal Hard Drives  
72-GB 15K RPM Hot Plug Serial Attached SCSI (SAS) 2.5-inch Drive AD379A
146-GB 10K RPM Hot Plug Serial Attached SCSI (SAS) 2.5-inch Drive AD333A
300-GB 10K RPM Serial Attached SCSI (SAS) 2.5-inch Small Form Factor Hot Plug Disk AM244A
HP Integrity 146GB 15K SAS SFF 3GB DP AM302A
Removable Media*  
DVD ROM Drive AD142A
DVD+RW Drive** AD143A
* Required for Windows, Linux and OpenVMS. Optional for HP UX. Maximum 1 supported.
** 3rd party software must be purchased to write to DVDs if Windows is the operating system. For HP-UX 11iv2, only DVD+R and DVD+RW media is supported. CD media is NOT supported
 
 
Integrated Multi-function Core I/O

The integrated multifunction I/O provides core I/O functionally and includes the integrated management processor, which provides remote management and high availability monitoring capabilities.

  • PCI-X Dual port 10/100/1000Base T LAN with RJ 45 connector-Supports LAN boot for operating system installation.
  • The base system offerings require choice of at least one HP 8 Port Serial Attached SCSI (SAS) controller. Choices vary depending on choice of I/O backplane (PCI-X 2.0 backplane or PCI-Express backplane) and choice of operating system. Please see Table 2.9.2 HP Integrity rx6600 Features - Standard System Features ealier in this chapter, or the section I/O Architecture beginning on page 2-230, and the rx6600 Ordering Guide.
  • Factory configured RAID is available with all Core I/O controllers. Please see Table 2.9.2 HP Integrity rx6600 Features - Standard System Features ealier in this chapter, or the section I/O Architecture beginning on page 2-230, and the rx6600 Ordering Guide. When configuring for RAID, all HDD's in the system must be the same size and speed.

Integrated Integrity iLO 2 Management Processor Functionality
  • Dedicated 10/100BaseTX LAN port for LAN console and embedded web console access.
  • One RS 232 serial port for local console.
  • Password protected console ports.
  • Console mirroring between all local, modem, LAN, and web consoles.
  • Remote power up and power down control.
  • Configurable remote access control.
  • Event notification to system console-Provides connectivity, information, and support for HP UX tools (such as STM and EMS) to notify by email, pager and/or HP response centers.
  • Interface to system monitoring and diagnostic hardware via an internal IC bus.
  • Secure Sockets Layer security on web console.
  • Support for Integrated Lights Out version 2 (iLO v2) Advanced Pack activation key and license (AD301A). Firmware license installs on the integrated Management Processor Card. Integrated Lights Out (iLO) Advanced Pack provides additional remote management capabilities, including integrated remote console and virtual CD/DVD drive, and LDAP directory services, SSH security, and Group Actions with HP Systems Insight Manager (SIM).
  • Basic graphic capabilities are available as an optional upgrade. The upgrade provides these capabilities via the Radeon 7000 2D graphics chip and 16 MB memory, which resides on the integrated Integrity iLO 2 management processor card. VGA port is provided on rear of the system. Supported resolutions and refresh rates include:
 
Operating System
Minimum Resolution
Refresh Rate
Maximum Resolution
Refresh Rate
HP-UX 1024x768 75 Hz 1920x1200 75 Hz
Linux 1024x768 75 Hz 1920x1200 75 Hz
Windows 640x480 75 Hz 1600x1200 75 Hz
OpenVMS 640x480 60 Hz 1920x1200 75 Hz

System Console Configurations The HP Integrity rx6600's integrated Management Processor Card provides six methods for console connections.
  • SSL secured Web console accessible through the 10/100Base T management LAN
  • Standard telnet connections accessible through the 10/100Base T management LAN
  • Local VT100 or hpterm terminal, or VT100 or hpterm emulator via local RS 232 serial connection
  • Remote VT100 or hpterm terminal, or VT100 or hpterm emulator via external modem
  • VGA graphics console using the upgrade to the VGA port. This upgrade is required for Windows systems and optional for HP UX and Linux systems. Keyboard and mouse connections are provided by USB. OpenVMS doesn't support VGA console for boot operations, but supports the VGA device for graphics use after boot.
  • Integrated Remote Console (virtual KVM) through the iLO 2 Advanced Pack (Windows systems only).

Internal Disk and Media Drives
  • The HP Integrity rx6600 supports up to sixteen internal Serial Attached SCSI (SAS) 2.5 inch hot plug disk drives.
  • A PCI-X or PCI-Express 8 port host bus adapter provides 8 ports, 1 port per SAS disk, for point to point connection from the adapter to the disk. This means that each disk has its own 3 GB link. A second HP 8 Internal port host bus adapter must be ordered to support disks 9 through 16.
  • Factory configured RAID is available with all Core I/O controllers. Please see Table 2.9.2 HP
  • Integrity rx6600 Features - Standard System Features ealier in this chapter, or the section I/O Architecture beginning on page 2-230, and the rx6600 Ordering Guide. When configuring for RAID, all HDD's in the system must be the same size and speed.
  • Cables required to connect the internal disk drives to the host bus adapter are shipped with the system; no need to order separately.
  • 36-GB 10K and 15K, 72-GB 10K and 15K, and 146-GB Serial Attached SCSI (SAS) disks are supported. 300 GB 10K SAS disks will be supported on all operating systems in a future release.
  • Optical media drives include a DVD ROM (AD142A) and DVD+RW (AD143A). A DVD drive is required for all OpenVMS, Linux, and Windows configurations. Third party software (not included with the AD143A) is required to support DVD write with Windows on AD143A. For HP-UX 11iv2, only DVD+R and DVD+RW media is supported. CD media is NOT supported.

HP Integrity rx6600 Trusted Platform Module

The rx6600 has an accessory option for an embedded security chip - the Trusted Platforms Module (TPM) - product number AB404A. HP-UX Trusted Computing Services (HP-UX TCS) provides software support for the TPM when running HP-UX 11i v2. By providing a low-cost embedded security chip option (known as a Trusted Platform Module) in its zx2-based Integrity servers (rx2660, rx3600, and rx6600), HP has established a foundation for strong protection of sensitive information - including cryptographic keys. Built around industry standards, the Trusted Platform Module (TPM) provides a basis for key storage by securely generating and storing cryptographic keys. HP-UX 11i TCS takes this a step further by providing the necessary infrastructure for managing the TPM, as well as integrating it into select features such as HP-UX Encrypted Volumes and File Systems (EVFS).

Using HP-UX TCS with EVFS:

Using HP-UX TCS to make the unattended boot capability of EVFS more secure is an important example of how HP-UX TCS can be integrated with other applications to enhance security. For more information see the "Protecting EVFS Keys with HP-UX TCS" chapter in the "HP-UX Trusted Computing Services Administrators Guide" available in the HP-UX Trusted Computing Services section at: http://docs.hp.com/en/internet.html

Please note that HP-UX 11iTCS requires:

(1) An HP zx2-based Integrity server (rx2660, rx3600, or rx6600) with a TPM installed, running HP-UX 11iv2 September 2006 release or later
(2) Installation of kernel patch PHKL_35428

To download TCS and EVFS, please see the HP-UX Software Depot web page at: http://software.hp.com


HP Integrity rx6600 Power Subsystem

The HP Integrity rx6600 provides a high level of integrated power protection:

  • N+1 redundant hot swap power supplies
  • N+1 redundant AC power input protection with electrical phase isolation
  • Power monitoring and control

The HP Integrity rx6600 supports a second hot swap power supply for N+1 protection. One supply is shipped as a standard part of every system and is required for correct operation. The hot swap design allows for the online replacement of a power supply when N+1=2 supplies are configured in the server.

The HP Integrity rx6600 provides an independent power input receptacle for each power supply. The independent design provides protection against losing the connection from a power cord or breaker. The HP Integrity rx6600 power cords should always be plugged into separate breakers when possible.

contents
 Overview      Standard Features      Configuration      Technical Specifications line.gif (50 bytes)

Technical Specifications

Server model numberrx6600 

Server product numbers Four processor/eight core capable HP Integrity rx6600 base system with one dual core processor module
AB464A
Configure with one 1.4 GHz/12 MB dual core 9120N processor module
AB464A#240
Configure with one 1.6 GHz/18 MB dual core 9140Nprocessor module
AB464A#260
Configure with one 1.6 GHz/24 MB dual core 9150Nprocessor module
AB464A#280
Base system includes one power supply (second supply can be ordered for redundancy) and a 2 port 10/100/1000 GbE PCI X card in one core I/O slot. Must select core I/O storage controller, I/O backplane, memory carrier board option, and memory (minimum 2 GB).
Four processor/eight core capable HP Integrity rx6600 base system with two dual core processor modules
AD132A
Configure with two 1.4 GHz/12 MB dual core 9120Nprocessor modules
AD132A#240
Configure with two 1.6 GHz/18 MB dual core 9140Nprocessor modules
AD132A#260
Configure with two 1.6 GHz/24 MB dual core 9150Nprocessor modules
AD132A#280
Base system includes one power supply (second supply can be ordered for redundancy) and a 2 port 10/100/1000 GbE PCI X card in one core I/O slot. Must select core I/O storage controller, I/O backplane, memory carrier board option, and memory (minimum 2 GB).
Four processor/eight core capable HP Integrity rx6600 base system with three dual core processor modules
AD133A
Configure with three 1.4 GHz/12 MB dual core 9120N processor modules
AD133A#240
Configure with three 1.6 GHz/18 MB dual core 9140N processor modules
AD133A#260
Configure with three 1.6 GHz/24 MB dual core 9150N processor modules
AD133A#280
Base system includes one power supply and a 2 port 10/100/1000 GbE PCI X card in one core I/O slot. Must select core I/O storage controller, I/O backplane, memory carrier board option, and memory (minimum 2 GB).  
Four processor/eight core capable HP Integrity rx6600 base system with four dual core processor modules
AD134A
Configure with four 1.4 GHz/12 MB dual core 9120Nprocessor modules
AD134A#240
Configure with four 1.6 GHz/18 MB dual core 9140Nprocessor modules
AD134A#260
Configure with four 1.6 GHz/24 MB dual core 9150Nprocessor modules
AD134A#280
Base system includes one power supply and a 2 port 10/100/1000 GbE PCI X card in one core I/O slot.
Must select core I/O storage controller, I/O backplane, memory carrier board option, and memory (minimum (2 GB).
 
Server Form Factor (Required - Must choose either field rack kit, factory rack integration, or optional standalone mount)
Please refer to the HP 10000 Series G2 Rack Best Practices Guide for information on rack deployment, stabilization and transportation. (http://www.HP.com/go/rackandpower)
Universal Rack Kit
AD053A
Field Rack Kit
Includes rack slides and cable management arm
AD053A#B01
Factory Rack Integration
AD053A#0D1
For factory rack integration, a rack cabinet must appear in the same section of the order. The slides and cable management arm will be installed with the server in the rack cabinet when factory rack integration is ordered.  
Optional Stand-Alone Pedestal Form Factor
NOTE: Will not be factory configured, will be shipped in a separate box for field installation only.
AD308A#B01

Supported Processors 1.6-GHz Dual-core Intel Itanium 9150N Processor
AD388A
Cache-On chip Level 1
32 KB
Cache-On chip Level 2
1-MB Instruction/256-KB Data (per core)
Cache-On chip Level 3
24-MB (12-MB per core)
Floating point Coprocessor included
Yes
1.6-GHz Dual-core Intel Itanium 9140N Processor
AD389A
Cache-On chip Level 1
32 KB
Cache-On chip Level 2
1-MB Instruction/256-KB Data (per core)
Cache-On chip Level 3
18-MB (9-MB per core)
Floating point Coprocessor included
Yes
1.4-GHz Dual-core Intel Itanium 9120N Processor
AH231A
Cache-On chip Level 1
32 KB
Cache-On chip Level 2
1-MB Instruction/256-KB Data (per core)
Cache-On chip Level 3
12-MB (6-MB per core)
Floating point Coprocessor included
Yes
NOTE: Two power cords are shipped with each system; one that connects the system to the rack PDU and one that enables direct connection to a wall socket. The cord that connects the system power supply to the PDU has an IEC 19 end, which plugs into the system power supply's IEC 20 socket, and an IEC 20 end, which plugs into the PDU's IEC 19 socket. The localized cord that connects the system power supply directly to the wall socket has an IEC 19 end, which plugs into the system power supply's IEC 20 socket, and a country specific end, which plus into the wall socket. This localized cord is included at the distribution site.

System Memory Minimum memory
2-GB
Maximum memory capacity
384-GB

Internal Disks Maximum disk mechanisms
16
Maximum disk capacity
4,800 GB

Standard Integrated I/O Serial Attached SCSI (SAS)
Please see specific system offerings for details
8 ports
10/100/1000Base T (RJ 45 connector)
2 ports
RS-232 serial ports
2
10/100Base T management port (RJ 45 connector)
1
USB (2.0) Ports
1 front/2 rear
VGA
Optional for HP UX, Linux, OpenVMS.
Required for Windows.

I/O Buses and Slots (Must select 1 only)I/O Backplane Option
AD296A
PCI-X 2.0 Backplane
AD296A#100
Available I/O slots
8
Two 266 MHz, 64 bit slots, each on its own dedicated PCI X bus
Two 133 MHz, 64 bit slots, each on its own dedicated PCI X bus
Four 66 MHz, 64 bit slots distributed on 2 PCI X buses; 2 slots per bus
PCI-Express Backplane
AD296A#300
NOTE: Not supported with HP-UX 11i v3 at this time.
Available I/O slots
8
Two x8 PCI-Express slots on one 1.3-GB/s bus
Two x8 PCI-Express slots, each on its own dedicated 2.6 GB/s bus
Two PCI-X 133-MHz, 64-bit slots, each on its own dedicated bus
Two PCI-X 66 MHz, 64 bit slots distributed on 1 PCI X bus

Maximum I/O Cards
(See supported I/O table for product specifics)
Additional Interface Cards
8

Electrical Characteristics AC Input power 200-240V 50-60Hz
Hot swap Power supplies 1 included, 2nd for N+1
Redundant AC power inputs 1 included, 2nd for N+1
Maximum input current at 200V 10 A
Typical power dissipation 998 Watts
Maximum power dissipation 1,633 Watts
Power factor at full load 0.95 or higher
Typical heat dissipation (BTUs/hour) 3,405
Maximum heat dissipation (BTUs/hour) 5,572
Maximum heat dissipation (BTUs/hour) 5,572

Site PreparationSite planning and installation included
NOTE: System is customer installable.
No
Rack system Depth
696 mm/27.4 in
Rack system Width
440 mm/17.32 in
Rack system height (EIA/mm)
306 mm/12.0 in/7 U
Rack system Weight (kg/lbs) maximum
68 kg/150 lbs
Pedestal system Depth
696 mm/27.4 in
Pedestal system Width
489 mm/19.3 in
Pedestal system height
422 mm/16.7 in
Pedestal system Weight (kg/lbs) maximum
86 kg/189 lbs

Environmental Characteristics Acoustics (operator/bystander) at 77° F (25° C) <6.9 Bels LwA
Operating Temperature (up to 5000 ft/1524 m) 41° to 95° F (5° to 35° C)
Max. rate of temperature change, operating 30 per hour
Non-operating Temperature 5° to 35° F (-40° to 70° C)
Maximum rate of temperature change,
non operating
20° per hour
Operating relative humidity 15% to 80% RH non-condensing
Non operating/storage humidity 5% to 95% non-condensing
Operating altitude above sea level 10,000 ft (3,000 m) maximum
Non-operating altitude above sea level 15,000 ft (4,600 m) maximum
NOTE: If the N+1 power supply is ordered standalone the power supply will ship with two cords; one that connects the system to the rack PDU and one that enables direct connection to a wall socket. The cord that connects the system power supply to the PDU has an IEC 19 end, which plugs into the system power supply's IEC 20 socket, and an IEC 20 end, which plugs into the PDU's IEC 19 socket. The localized cord that connects the system power supply directly to the wall socket has an IEC 19 end, which plugs into the system power supply's IEC 20 socket, and a country specific end, which plugs into the wall socket. This localized cord is included at the distribution site.
If the N+1 power supply is ordered with the server, the additional cords will be included.

Regulatory ComplianceRMNRSVLA-0405
Electromagnetic interferenceComplies with FCC Rules and Regulations, Part 15 as a Class A digital device. Manufacturer's Declaration to EN55022 Level A, VCCI Registered,
Class A, Korea RLL.
SafetyUL Listed, CSA Certified, TUV GS Mark compliant with EN 60950 and EN 41003
More detailed regulatory documents and certificationshttp://docs.hp.com/en/hw.html

© Copyright 2009 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.

Intel and Itanium are registered trademarks or trademarks of Intel Corporation in the U.S. and/or other countries.

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.


   DA-12596 36 - Version 36 - September 1, 2009