Overview
|
HP Integrity rx6600 Server |
|
|
|
HP Integrity rx6600 System Overview
(Interior View)
|
|||
![]() |
|||
| 1. | Recessed Carrying Handles | 3. | 8 Hot Plug PCI-X 10 Slots (2 @ 266 MHz) |
| 2. | Redundant Bulk Power | 4. | Hot Swap Fans |
| HP Integrity rx6600 | |||
![]() |
|||
| 1. | 7U Chassis | 3. | 4 Clamshell CPU Sockets |
| 2. | 16 SAS HDDs | 4. | 48 DDR2 DIMM Slots |
|
|
Standard Features
| Minimum System |
|
| | |
| Maximum Server Capacities |
|
| | |
| Standard System Features |
|
| | |
| High Availability |
|
|
| |
| Security |
|
| | |
| Manageability
- Deploy |
|
| Manageability - Monitor |
|
| Manageability - Optimize |
*Please note that the last order date for Windows Server 2003 is Feb 28, 2009. However, Microsoft provides downgrade rights for the customers to purchase WS 2008 downgrade from Windows Server 2008 to Windows Server 2003. Customers can continue to buy WS 2003 license directly from Microsoft. |
|
|
Configuration
| Processor Configuration | The HP Integrity rx6600 is a symmetrical multiprocessing (SMP) server supporting up to four high performance 64 bit dual core Intel Itanium processors. The dual core Intel Itanium processor supports hyper threading. Each core of the processor supports two threads. |
|
| |
| Processor Details | Dual core Intel Itanium processors:
|
|
| |
| Processor Configuration Rules |
|
|
|
|
| Memory Configuration |
The HP Integrity rx6600 supports double data rate (DDR2) synchronous
dynamic random access memory (SDRAM) DIMMs with ECC and double chip spare
protection. The HP Integrity rx6600 can be ordered with one of the following
two memory carrier boards:
|
| Memory Loading Rules | |
|
|
| Memory Options | |
| Description | Product Number |
| 4-GB chip spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×1GB DIMMs) | AB564A |
| 8-GB chip spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×2GB DIMMs) | AB565A |
| 16-GB chip spare PC2-4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×4GB DIMMs) | AB566A |
| 32-GB chip spare PC2 4200 ECC x4 single rank Registered DDR2 SDRAM memory quad (4×8GB DIMMs) | AH405A |
| Server Form Factor and Rack Configuration | The
HP Integrity rx6600 is a 7U rack optimized server. It is supported in HP 10000
G2 series cabinets. For factory integration order AD053A with 0D1 feature code.
Sliding mounts and a cable management arm will be installed with the server in
a factory integrated rack. The HP Integrity rx6600 can be installed in the field with the Field Rack Kit (AD053A with B01 feature code). This field kit contains the slide mounts, cable management arm, and all other hardware needed to mount an rx6600 into a 19 inch cabinet. Refer to the 10000 G2 Series Rack Best Practices Guide for information on rack deployment, stabilization and transportation. Go to: http://www.hp.com/go/rackandpower for more information. The rx6600 is also available in a stand-alone, pedestal form factor (AD308A). Kit will be shipped in a separate box for field installation only. |
| | |
| I/O Architecture |
|
The HP Integrity rx6600 supports two I/O backplane options in order to provide maximum flexibility, I/O card availability, performance, scalability and reliability. The two options are a PCI-X 2.0 Backplane (AD296A#100) or a PCI-Express Backplane option (AD296A#300). Only one backplane per system is supported. PCI-X
2.0 Backplane: Each port of a Serial Attached SCSI card can be connected to a Serial Attached SCSI hard disk drive. When more than eight hard disk drives are required, a second HP PCI-X 8 port SAS card must be ordered. This second SAS card will be installed in the second core I/O slot, and the PCI-X dual port 10/100/1000Base TX LAN adapter will be moved out to a standard I/O slot. Note that when the LAN adapter is moved out to a standard I/O slot, Wake On LAN is not supported. HP-UX and OpenVMS based systems with PCI-X 2.0 Backplane: Windows and Linux based systems with PCI-X 2.0 Backplane: Remaining Eight (non-Core I/O) slots: The remaining four slots (#7 through #10) share two 64 bit 66 MHz PCI X buses, with two slots allocated to each bus. Each pair of slots shares a 0.5 GB/s I/O channel. NOTE: Hot plug operations are not supported with the Linux or OpenVMS operating systems or in the core I/O slots with any operating system. All I/O slots are keyed for I/O cards with 3.3V signaling. Cards that use 5V signaling are not supported in the HP Integrity rx6600. PCI-Express
Backplane: Each port of a Serial Attached SCSI card can be connected to a Serial Attached SCSI hard disk drive. When more than eight hard disk drives are required, a second 8 port Serial Attached SCSI card must be ordered. If a PCI-X card is chosen, it will be installed in the reserved PCI-X core I/O slot. If a PCI-Express card is chosen, it will be installed in slot #4. HP-UX and OpenVMS based systems with PCI-Express Backplane:
NOTE: MirrorDisk/UX is available for SW Mirroring on all HDDs in HP UX based systems and HP Volume Shadowing (software Raid 1) for HDDs in OpenVMS-based systems. Windows and Linux based systems with PCI-Express Backplane:
Remaining Eight (non-Core I/O)
slots: The remaining four slots (#7 through #10) are PCI-X slots. Slots #7 and #8 each have their own dedicated 64 bit 133 MHz PCI-X channel; slot #7 is 1.1 GB/s and slot #8 is 0.5 GB/s. Slots #9 and #10 share a 64-bit 66-MHz PCI-X 0.5 GB/s I/O channel. NOTE: Hot plug operations are not supported with the Linux or OpenVMS operating systems or in the PCI X Core I/O slots with any operating system. Hot plug operations are not supported for any operating system in slots #3 or #4. All I/O slots are keyed for I/O cards with 3.3V signaling. Cards that use 5V signaling are not supported in the HP Integrity rx6600. |
| Supported I/O Cards |
| Supported HP-UX I/O Cards |
| I/O Card |
Product Number
|
PCIe/
PCI-X |
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane |
Maximum Cards
PCI-Express Backplane |
Special Notes
|
| Multi function Cards (Mass Storage/LAN) | |||||||
| HP PCI-X 1 port 4 GB Fibre Channel/1 port 1000Base T Adapter |
AD193A
|
PCI-X
|
Yes
|
1 LC, 1 RJ-45
|
8
|
4
|
|
| HP PCI-X 2 port 4 GB Fibre Channel/2 port 1000Base T Adapter |
AD194A
|
PCI-X
|
Yes
|
2LC, 2 RJ-45
|
8
|
4
|
|
| PCI-X 2 Gb Fibre Channel/1000Base SX |
A9782A
|
PCI-X
|
Yes
|
LC
|
For maximum performance, card should not be installed
in a shared slot.
|
||
| PCI-X 2 port 1000Base T/2 port U320 Multi function Adapter |
AB290A
|
PCI-X
|
Yes
|
SCSI - LVD/SE
LAN - RJ-45 |
6
|
2
|
|
| Local Area Network (LAN) Adapters | |||||||
| PCIe 4-Gb Fibre Channel/GbE-T HBA combo |
AD221A
|
PCIe
|
Yes
|
0
|
4
|
|
|
| PCIe 2-port 4-Gb Fibre Channel/2-port GbE-T HBA combo |
AD222A
|
PCIe
|
Yes
|
0
|
4
|
|
|
| PCIe 2-port 4-Gb Fibre Channel/2-port GbE-SX HBA combo |
AD393A
|
PCIe
|
Yes
|
0
|
4
|
|
|
| PCI-X 1 port 1000Base T (gigabit copper) |
AD331A
|
PCI-X
|
No
|
RJ-45
|
8
|
4
|
|
| PCI-X 2 port 1000Base T |
A7012A
|
PCI-X
|
Yes
|
RJ-45
|
8
|
4
|
|
| PCI-X 4 port 1000Base T 1GbE Adapter |
AB545A
|
PCI-X
|
Yes
|
RJ-45
|
8
|
4
|
|
| PCI-X 1 port 1000Base SX (gigabit fiber) |
AD332A
|
PCI-X
|
No
|
Duplex SC
|
8
|
4
|
|
| PCI-X 2 port 1000Base SX |
A7011A
|
PCI-X
|
Yes
|
Duplex SC
|
8
|
4
|
|
| PCI-X 1 port 10GbE |
AB287A
|
PCI-X
|
Yes
|
Duplex LC
|
4
|
2
|
For best performance, recommend at least one processor
core per card installed in the system. Each card requires 512 MB of memory.
Card cannot be installed in a shared slot.
|
| HP PCIe 2-port 1000Base-T card |
AD337A
|
PCIe
|
Yes
|
RJ-45
|
0
|
4
|
|
| HP PCIe 2-port 1000Base-SX card |
AD338A
|
PCIe
|
Yes
|
Duplex SC
|
0
|
4
|
|
| PCIe 2-port 4X DDR Fast IB HCA |
AH304A
|
PCIe
|
No
|
|
0
|
4
|
|
| HP PCI-e 10GbE SR card |
AD386A
|
PCIe
|
Yes
|
0
|
4
|
||
| PCIe 4-port HP NC364T Gbit Adapter |
AD339A
|
PCIe
|
Yes
|
0
|
4
|
||
| PCI-X 266-MHz 1 port 10GbE |
AD385A
|
PCI-X
|
Yes
|
Duplex LC
|
4
|
2
|
For best performance, recommend at least one processor core per card installed in the system. Each card requires 512 MB of memory. Card cannot be installed in a shared slot. |
| Fibre Channel Storage Network Adapters Cards | |||||||
| HP PCIe 1-port 4-Gb/s Fibre Channel HBA |
AD299A
|
PCIe
|
No
|
LC
|
0
|
2
|
|
| HP PCIe 2-port 4-Gb/s Fibre Channel HBA |
AD355A
|
PCIe
|
No
|
LC |
0
|
2
|
|
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AB378B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
2
|
|
| Fibre Channel Cards | |||||||
| PCI 2 channel Ultra320 SCSI |
A7173A |
PCI-X
|
Yes
|
VHDCI
|
8
|
4
|
|
| HP PCIe SC44Ge SAS HBA | AH303A | PCIe | Yes | 0 | 4 | ||
| HP PCIe 1-port 8Gb FC SR (Qlogic) HBA | AH400A | PCIe | Yes | 0 | 2 | Total of four cards are supported with the AB463-2163A backplane, making slots 3 and 4 possible. Without the new backplane, PCIe Gen2 cards do not function in those slots | |
| HP PCIe 2-port 8Gb FC SR (Qlogic) HBA | AH401A | PCIe | Yes | 0 | 2 | Maximum two cards are supported with HP-UX. With OpenVMS and Windows, total of four cards are supported with the AB463 2163A backplane, making slots 3 and 4 possible. Without the new backplane, PCIe Gen2 cards do not function in those slots | |
| RAID Adapters Cards | |||||||
| PCI-X 2 channel Smart Array 6402 Ultra320 |
A9890A
|
PCI-X
|
Yes
|
VHDCI
|
6
|
2
|
Requires minimum of 512 MB of memory and full length slot |
| PCI-X 4 channel Smart Array 6404 Ultra320 |
A9891A
|
PCI-X
|
Yes
|
VHDCI
|
6
|
1
|
Requires minimum of 512 MB of memory and full length slot
|
| PCIe Smart Array P800 |
AD335A
|
PCIe
|
Yes
|
Mini SAS
|
0
|
4
|
|
| Wide Area Network (WAN) Adapters | |||||||
| 2 port Programmable Serial Interface
(PSI) X.25/Frame Relay/SDLC |
J3525A | PCI-X | No | RS 530, RS 232, V.35, RS 449 or X.21 | 8 | 4 | |
| Cluster Interconnect | |||||||
| PCI-X 2 port 4x Fabric (HPC) Adapter | AB286C | PCI-X | No | 4x Infiniband Copper | 8 | 4 | For maximum performance, card should not be installed in a shared slot. Requires a minimum of 512 MB memory. |
| PCIe 2 port 4x Fabric (PHC) Adapter | AD313A | PCIe | No | 4x Infiniband Copper | 0 | 4 | |
| PCI 8 port Serial MUX Adapter | AD278A | PCI-X | No | 8 | 4 | ||
| PCI 64 port Serial MUX Adapter | AD279A | PCI-X | No | 8 | 4 | ||
| 16 port RS 232 RJ45 Port Module | AD280A | No | 4 per AD279A | N/A | N/A | AD280A #001 Port Module Power Supply, required on Port Module (3) and Port Module (4) connected to an AD279A 64 port MUX adapter. | |
| 16-port RS-232 DB-25 Port Module | AD281A | No | 4 per AD279A | N/A | AD281A #001 Port Module Power Supply, required on Port Module (3) and Port Module (4) connected to an AD279A 64 port MUX adapter. | ||
| Graphics Cards | |||||||
| HP 2D PCI-X graphics card | AH391A | PCI | No | VGA | 2 | 2 | T/P/I: HP UX PCI-x and PCI-x/PCI-e 2/2/2 |
| Supported OpenVMS I/O Cards |
| I/O Card |
Product Number
|
PCIe/
PCI-X |
Boot Support
|
Connector Type(s)
|
Maximum Cards
PCI-X Backplane |
Maximum Cards
PCI-Express Backplane |
Special Notes
|
| Combination Cards | |||||||
| HP PCI-X 1 port 4 GB Fibre Channel/1 port 1000Base T Adapter |
AD193A
|
PCI-X
|
Yes
|
1 LC, 1 RJ-45
|
2
|
2
|
|
| HP PCI-X 2 port 4 GB Fibre Channel/2 port 1000Base T Adapter |
AD194A
|
PCI-X
|
Yes
|
2LC, 2 RJ-45
|
2
|
2
|
|
| PCI-X 2 Gb Fibre Channel/1000Base SX |
A9782A
|
PCI-X
|
Yes
|
LC
|
4
|
4
|
For maximum performance, card should not be installed
in a shared slot.
|
| PCI-X 2 port 1000Base T/2 port U320 Multi function Adapter |
AB290A
|
PCI-X
|
Yes
|
SCSI - LVD/SE
LAN - RJ-45 |
2
|
2
|
Requires full length slot. |
| Local Area Network (LAN) Adapters | |||||||
| PCIe 4 Gb Fibre Channel/GbE T HBA combo | AD221A | PCIe | Yes | 0 | 2 | ||
| PCIe 2 port 4 Gb Fibre Channel/2 port GbE T HBA combo | AD222A | PCIe | Yes | 0 | 2 | ||
| PCIe 2 port 4 Gb Fibre Channel/2 port GbE SX HBA combo | AD393A | PCIe | Yes | 0 | 2 | ||
| PCI-X 1 port 1000Base T (gigabit copper) |
AD331A
|
PCI-X
|
No
|
RJ-45
|
8
|
4
|
|
| PCI-X 2 port 1000Base T |
A7012A
|
PCI-X
|
No
|
RJ-45
|
8
|
4
|
|
| HP PCI-X 4-Port 1000Base-T Gigabit Adapter |
AB545A
|
PCI-X
|
Yes
|
3
|
3
|
|
|
| PCI-X 1 port 1000Base SX (gigabit fiber) |
AD332A
|
PCI-X
|
No
|
Duplex SC
|
8
|
4
|
|
| PCI-X 2 port 1000Base SX |
A7011A
|
PCI-X
|
No
|
Duplex SC
|
8
|
4
|
|
| PCI-X 1 Port 10GbE |
AB287A
|
PCI-X
|
No
|
Duplex LC
|
2
|
2
|
|
| HP PCIe 2-port 1000Base-T Card |
AD337A
|
PCIe
|
Yes
|
0
|
4
|
||
| HP PCIe 2-port 1000Base-SX Card | AD338A | PCIe | Yes | 0 | 4 | ||
| PCIe 4-port HP NC364T Gbit Adapter | AD339A | PCIe | No | 0 | 4 | ||
| PCI-X 266MHz 10GigE SR Card | AD385A | PCI-X | Yes | 2 | 2 | ||
| Fibre Channel Storage Network Adapters Cards | |||||||
| HP PCIe 1-port 4-Gb/s Fibre Channel HBA |
AD299A
|
PCIe
|
No
|
LC
|
0
|
4
|
|
| HP PCIe 2-port 4-Gb/s Fibre Channel HBA |
AD355A
|
PCIe
|
No
|
LC |
0
|
4
|
|
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel |
AB378B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel |
AB379B
|
PCI-X
|
Yes
|
LC
|
8
|
4
|
|
| PCIe 2 port 4 Gb/s Fibre Channel |
AD300A
|
PCIe
|
Yes
|
LC
|
0
|
4
|
|
| Fibre Channel Cards | |||||||
| PCI 2 channel Ultra320 SCSI |
A7173A
|
PCI-X
|
Yes
|
VHDCI
|
4
|
4
|
No On Line Add and Replace support.
|
| HP PCIe SC44Ge SAS HBA | AH303A | PCIe | Yes | 0 | 4 | ||
| RAID Adapters Cards | |||||||
| PCI-X 2 channel Smart Array 6402 Ultra320 | A9890A | PCI-X | Yes | VHDCI | 2 | 2 | Requires minimum of 512 MB of memory and full length slot |
| PCI-X 2 channel Smart Array 6404 Ultra320 | A9891A | PCI-X | Yes | VHDCI | 1 | 1 | Requires minimum of 512 MB of memory and full length slot |
| PCIe Smart Array P800 | AD335A | PCIe | Yes | Mini SAS | 0 | 4 | |
| Graphics Cards | |||||||
| HP 2D PCI-X graphics card | AH391A | PCI | No | VGA | 4 | 3 | RNo OpenVMS factory integration. AH391A offers 2D graphics support. Support available for OpenVMS 8.3-1h1 and 8.3. OpenVMS PCI-x 4/4/4, PCI-e 3/3/3 |
| Supported Windows I/O Cards |
| NOTE: |
| I/O Card |
Product Number |
PCIe/ PCI-X |
Boot Support |
Connector Type(s) |
Maximum Cards PCI-X Backplane |
Maximum Cards PCI-Express Backplane |
Special Notes |
| Local Area Network (LAN) Adapters | |||||||
| PCI 2 port Windows/Linux 1000Base TX |
A9900A |
PCI-X |
No |
RJ-45 |
6 |
4 | No
On Line Add and Replace support. |
| HP PCI-X 2-port 1000Base-SX (optical) Gigabit Adapter |
A7011A |
PCI-X |
Yes |
6 |
4 | | |
| PCI-X 1 port 10 GbE |
AD144A |
PCI-X |
Yes |
Duplex LC |
4 |
4 | Each
card requires 512 MB of memory. Card cannot be installed in a shared slot. |
| HP PCIe 2-port 1000Base-T card |
AD337A |
PCIe |
Yes |
RJ-45 |
0 |
4 | |
| HP PCIe 2-port 1000Base-SX card |
AD338A |
PCIe |
Yes |
Duplex SC |
0 |
4 | |
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel | AB429A |
PCI-X |
Yes |
LC |
6 |
4 | |
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel | AB379B | PCI-X | Yes | LC | 6 | 4 | Replaces AB379A |
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel | AD167A | PCI-X | Yes | LC | 6 | 4 | |
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel | AD168A | PCI-X | Yes | LC | 6 | 4 | |
| PCIe 1 port 4 Gb/s Emulex Fibre Channel | A8002A | PCIe | Yes | LC | 0 | 4 | |
| PCIe 2 port 4 Gb/s Emulex Fibre Channel | A8003A | PCIe | Yes | LC | 0 | 4 | |
| PCIe 1 port 4 Gb/s Fibre Channel | AE311A | PCIe | Yes | LC | 0 | 4 | |
| PCIe 2 port 4 Gb/s Fibre Channel | AD300A | PCIe | Yes | LC | 0 | 4 | |
| HP PCI X 266 MHz 10GigE SR Card | AD385A | PCI-X | Yes | 4 | 4 | ||
| Fibre Channel Cards | |||||||
| PCI 2 channel Ultra320 SCSI | A7173A | PCI-X | Yes | VHDCI | 2 | 2 | |
| PCIe Smart Array P500 | AH226A | PCIe | Yes | Mini SAS | 0 | 4 | |
| PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller (for external storage only) | 337972-B21 | PCI-X | Yes | SFF8470 | 6 | 4 | A maximum of (4) may be ordered with #0D1, the remaining (2) must be ordered without #0D1 |
| 512 MB cache memory upgrade for SA640x and SA P600 controller | 372538-B21 | PCI-X | N/A | N/A | N/A | N/A | |
| PCIe Smart Array P800 | AD335A | PCIe | Yes | Mini SAS | 0 | 4 | |
| HP PCIe 1 port 8 Gb FC SR (Qlogic) HBA | AH400A | PCIe | Yes | 0 | 4 | ||
| HP PCIe 2 port 8 Gb FC SR (Qlogic) HBA | AH401A | PCIe | Yes | 0 | 4 | ||
| HP PCIe 1-port 8 Gb FC SR (Emulex) HBA | AH402A | PCIe | Yes | 0 | 4 | ||
| HP PCIe 2-port 8 Gb FC SR (Emulex) HBA | AH403A | PCIe | Yes | 0 | 4 | ||
| Supported Linux (RHEL 4 U4 and SLES 10) I/O Cards |
| I/O Card |
Product Number |
PCIe/ PCI-X |
Boot Support |
Connector Type(s) |
Maximum Cards PCI-X Backplane |
Maximum Cards PCI-Express Backplane |
Special Notes |
| Local Area Network (LAN) Adapters | |||||||
| PCI 2 port Windows/Linux 1000Base TX |
A9900A |
PCI-X |
No | RJ-45 |
8 | 4 |
No On Line Add and Replace support. |
| HP PCI-X 2-port 1000Base-SX (optical) Gigabit Adapter |
A7011A |
PCI-X |
Yes | 8 |
4 | ||
| HP PCIe 2-port 1000Base-T card |
AD337A |
PCIe |
Yes |
RJ-45 |
0 | 4 |
|
| HP PCIe 2-port 1000Base-SX card | AD338A | PCIe | Yes | Duplex SC | 0 | 4 | |
| AD385A - HP PCI-X 266MHz 10GigE SR Card | AD385A | Yes | 2 | 2 | |||
| Fibre Channel Storage Network Adapters | |||||||
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel | AB429A | PCI-X | Yes | LC | 4 | 2 | Qlogic and Emulex HBAs are not supported in the same server. |
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel | AB379B | PCI-X | Yes | LC | 4 | 2 | Replaces AB379A |
| PCI-X 266 MHz 1 channel 4 Gb/s Fibre Channel | AD167A | PCI-X | Yes | LC | 6 | 0 | Qlogic and Emulex HBAs are not supported in the same server. No On Line Add and Replace support. |
| PCI-X 266 MHz 2 channel 4 Gb/s Fibre Channel | AD168A | PCI-X | Yes | LC | 6 | 0 | Qlogic and Emulex HBAs are not supported in the same server. No On Line Add and Replace support. |
| PCIe 1 port 4 Gb/s Emulex Fibre Channel | A8002A | PCIe | Yes | LC | 0 | 4 | |
| PCIe 2 port 4 Gb/s Emulex Fibre Channel | A8003A | PCIe | Yes | LC | 0 | 4 | |
| PCIe 1 port 4 Gb/s Fibre Channel | AE311A | PCIe | No | LC | 0 | 4 | |
| PCIe 2 port 4 Gb/s Fibre Channel | AD300A | PCIe | Yes | LC | 0 | 4 | |
| Fibre Channel Cards | |||||||
| PCI 2 channel Ultra320 SCSI | A7173A | PCI-X | Yes | VHDCI | 4 | 4 | No On Line Add and Replace support. |
| HP PCIe Smart Array E500 SAS Controller | AH226A | PCIe | Yes | 0 | 4 | ||
| HP PCIe SC44Ge SAS HBA | AH303A | PCIe | No | 0 | 4 | Connect to external SAS tape drives only. | |
| RAID Adapters Cards | |||||||
| PCI-X Smart Array P600 Serial Attached SCSI (SAS) Controller (for external storage only) | 337972-B21 | PCI-X | Yes | SFF8470 | 4 | 4 | |
| 512 MB cache memory upgrade for SA640x and SA P600 controller | 372538-B21 | PCI-X | N/A | N/A | N/A | N/A | |
| PCIe Smart Array P800 | AD335A | PCIe | No | Mini SAS | 0 | 4 | |
| Support Internal Storage Devices | Product Number |
| Device | |
| Internal Hard Drives | |
| 72-GB 15K RPM Hot Plug Serial Attached SCSI (SAS) 2.5-inch Drive | AD379A |
| 146-GB 10K RPM Hot Plug Serial Attached SCSI (SAS) 2.5-inch Drive | AD333A |
| 300-GB 10K RPM Serial Attached SCSI (SAS) 2.5-inch Small Form Factor Hot Plug Disk | AM244A |
| HP Integrity 146GB 15K SAS SFF 3GB DP | AM302A |
| Removable Media* | |
| DVD ROM Drive | AD142A |
| DVD+RW Drive** | AD143A |
| *
Required for Windows, Linux and OpenVMS. Optional for HP UX. Maximum 1 supported. ** 3rd party software must be purchased to write to DVDs if Windows is the operating system. For HP-UX 11iv2, only DVD+R and DVD+RW media is supported. CD media is NOT supported |
| Integrated Multi-function Core I/O |
The integrated multifunction I/O provides core I/O functionally and includes
the integrated management processor, which provides remote management
and high availability monitoring capabilities.
|
| | |
| Integrated Integrity iLO 2 Management Processor Functionality |
|
|
|||||||||||||||||||||||||
|
|
| System Console Configurations | The HP Integrity rx6600's integrated Management
Processor Card provides six methods for console connections.
|
| | |
| Internal Disk and Media Drives |
|
| | |
| HP Integrity rx6600 Trusted Platform Module | The rx6600 has an accessory option
for an embedded security chip - the Trusted Platforms Module (TPM) - product
number AB404A. HP-UX Trusted Computing Services (HP-UX TCS) provides software
support for the TPM when running HP-UX 11i v2. By providing a low-cost embedded
security chip option (known as a Trusted Platform Module) in its zx2-based
Integrity servers (rx2660, rx3600, and rx6600), HP has established a foundation
for strong protection of sensitive information - including cryptographic
keys. Built around industry standards, the Trusted Platform Module (TPM)
provides a basis for key storage by securely generating and storing cryptographic
keys. HP-UX 11i TCS takes this a step further by providing the necessary
infrastructure for managing the TPM, as well as integrating it into select
features such as HP-UX Encrypted Volumes and File Systems (EVFS).
Using HP-UX TCS with EVFS: Using HP-UX TCS to make the unattended boot capability of EVFS more secure is an important example of how HP-UX TCS can be integrated with other applications to enhance security. For more information see the "Protecting EVFS Keys with HP-UX TCS" chapter in the "HP-UX Trusted Computing Services Administrators Guide" available in the HP-UX Trusted Computing Services section at: http://docs.hp.com/en/internet.html Please note that HP-UX 11iTCS requires: (1) An HP zx2-based Integrity server (rx2660, rx3600, or rx6600) with
a TPM installed, running HP-UX 11iv2 September 2006 release or later |
| | |
| HP Integrity rx6600 Power Subsystem |
The HP Integrity rx6600 provides a high level of integrated power protection:
The HP Integrity rx6600 supports a second hot swap power supply for N+1 protection. One supply is shipped as a standard part of every system and is required for correct operation. The hot swap design allows for the online replacement of a power supply when N+1=2 supplies are configured in the server. The HP Integrity rx6600 provides an independent power input receptacle for each power supply. The independent design provides protection against losing the connection from a power cord or breaker. The HP Integrity rx6600 power cords should always be plugged into separate breakers when possible. |
|
|
Technical Specifications
| Server model number | rx6600 | |
| | ||
| Server product numbers | Four processor/eight core capable HP Integrity rx6600 base system with one dual core processor module |
AB464A
|
| Configure with one 1.4 GHz/12 MB dual core 9120N processor module |
AB464A#240
|
|
| Configure with one 1.6 GHz/18 MB dual core 9140Nprocessor module |
AB464A#260
|
|
| Configure with one 1.6 GHz/24 MB dual core 9150Nprocessor module |
AB464A#280
|
|
| Base system includes one power supply (second supply can be ordered for redundancy) and a 2 port 10/100/1000 GbE PCI X card in one core I/O slot. Must select core I/O storage controller, I/O backplane, memory carrier board option, and memory (minimum 2 GB). | ||
| Four processor/eight core capable HP Integrity rx6600 base system with two dual core processor modules |
AD132A
|
|
| Configure with two 1.4 GHz/12 MB dual core 9120Nprocessor modules |
AD132A#240
|
|
| Configure with two 1.6 GHz/18 MB dual core 9140Nprocessor modules |
AD132A#260
|
|
| Configure with two 1.6 GHz/24 MB dual core 9150Nprocessor modules |
AD132A#280
|
|
| Base system includes one power supply (second supply can be ordered for redundancy) and a 2 port 10/100/1000 GbE PCI X card in one core I/O slot. Must select core I/O storage controller, I/O backplane, memory carrier board option, and memory (minimum 2 GB). | ||
| Four processor/eight core capable HP Integrity rx6600 base system with three dual core processor modules |
AD133A
|
|
| Configure with three 1.4 GHz/12 MB dual core 9120N processor modules |
AD133A#240
|
|
| Configure with three 1.6 GHz/18 MB dual core 9140N processor modules |
AD133A#260
|
|
| Configure with three 1.6 GHz/24 MB dual core 9150N processor modules |
AD133A#280
|
|
| Base system includes one power supply and a 2 port 10/100/1000 GbE PCI X card in one core I/O slot. Must select core I/O storage controller, I/O backplane, memory carrier board option, and memory (minimum 2 GB). | ||
| Four processor/eight core capable HP Integrity rx6600 base system with four dual core processor modules |
AD134A
|
|
| Configure with four 1.4 GHz/12 MB dual core 9120Nprocessor modules |
AD134A#240
|
|
| Configure with four 1.6 GHz/18 MB dual core 9140Nprocessor modules |
AD134A#260
|
|
| Configure with four 1.6 GHz/24 MB dual core 9150Nprocessor modules |
AD134A#280
|
|
| Base system includes one power
supply and a 2 port 10/100/1000 GbE PCI X card in one core I/O slot. Must select core I/O storage controller, I/O backplane, memory carrier board option, and memory (minimum (2 GB). |
||
| Server Form Factor (Required - Must choose either field rack kit, factory rack integration, or optional standalone mount) | ||
| Please refer to the HP 10000 Series G2 Rack Best Practices Guide for information on rack deployment, stabilization and transportation. (http://www.HP.com/go/rackandpower) | ||
| Universal Rack Kit |
AD053A
|
|
| Field Rack Kit Includes rack slides and cable management arm |
AD053A#B01
|
|
| Factory Rack Integration |
AD053A#0D1
|
|
| For factory rack integration, a rack cabinet must appear in the same section of the order. The slides and cable management arm will be installed with the server in the rack cabinet when factory rack integration is ordered. | ||
| Optional Stand-Alone Pedestal
Form Factor NOTE: Will not be factory configured, will be shipped in a separate box for field installation only. |
AD308A#B01
|
|
|
|
||
| Supported Processors | 1.6-GHz Dual-core Intel Itanium 9150N Processor |
AD388A
|
| Cache-On chip Level 1 |
32 KB
|
|
| Cache-On chip Level 2 |
1-MB Instruction/256-KB Data (per core)
|
|
| Cache-On chip Level 3 |
24-MB (12-MB per core)
|
|
| Floating point Coprocessor included |
Yes
|
|
| 1.6-GHz Dual-core Intel Itanium 9140N Processor |
AD389A
|
|
| Cache-On chip Level 1 |
32 KB
|
|
| Cache-On chip Level 2 |
1-MB Instruction/256-KB Data (per core)
|
|
| Cache-On chip Level 3 |
18-MB (9-MB per core)
|
|
| Floating point Coprocessor included |
Yes
|
|
| 1.4-GHz Dual-core Intel Itanium 9120N Processor |
AH231A
|
|
| Cache-On chip Level 1 |
32 KB
|
|
| Cache-On chip Level 2 |
1-MB Instruction/256-KB Data (per core)
|
|
| Cache-On chip Level 3 |
12-MB (6-MB per core)
|
|
| Floating point Coprocessor included |
Yes
|
|
| NOTE: Two power cords are shipped with each system; one that connects the system to the rack PDU and one that enables direct connection to a wall socket. The cord that connects the system power supply to the PDU has an IEC 19 end, which plugs into the system power supply's IEC 20 socket, and an IEC 20 end, which plugs into the PDU's IEC 19 socket. The localized cord that connects the system power supply directly to the wall socket has an IEC 19 end, which plugs into the system power supply's IEC 20 socket, and a country specific end, which plus into the wall socket. This localized cord is included at the distribution site. | ||
|
|
||
| System Memory | Minimum memory |
2-GB
|
| Maximum memory capacity |
384-GB
|
|
|
|
||
| Internal Disks | Maximum disk mechanisms |
16
|
| Maximum disk capacity |
4,800 GB
|
|
|
|
||
| Standard Integrated I/O | Serial Attached SCSI (SAS) Please see specific system offerings for details |
8 ports
|
| 10/100/1000Base T (RJ 45 connector) |
2 ports
|
|
| RS-232 serial ports |
2
|
|
| 10/100Base T management port (RJ 45 connector) |
1
|
|
| USB (2.0) Ports |
1 front/2 rear
|
|
| VGA |
Optional for HP UX, Linux, OpenVMS.
Required for Windows. |
|
|
|
||
| I/O Buses and Slots (Must select 1 only) | I/O Backplane Option | AD296A |
| PCI-X 2.0 Backplane |
AD296A#100
| |
| Available I/O slots | 8 | |
| Two 266 MHz, 64 bit slots, each on its own dedicated PCI X bus | ||
| Two 133 MHz, 64 bit slots, each on its own dedicated PCI X bus | ||
| Four 66 MHz, 64 bit slots distributed on 2 PCI X buses; 2 slots per bus | ||
| PCI-Express Backplane |
AD296A#300
| |
| NOTE: Not supported with HP-UX 11i v3 at this time. | ||
| Available I/O slots | 8 | |
| Two x8 PCI-Express slots on one 1.3-GB/s bus | ||
| Two x8 PCI-Express slots, each on its own dedicated 2.6 GB/s bus | ||
| Two PCI-X 133-MHz, 64-bit slots, each on its own dedicated bus | ||
| Two PCI-X 66 MHz, 64 bit slots distributed on 1 PCI X bus | ||
|
| ||
| Maximum I/O Cards (See supported I/O table for product specifics) |
Additional Interface Cards |
8
|
|
|
||
| Electrical Characteristics | AC Input power | 200-240V 50-60Hz |
| Hot swap Power supplies | 1 included, 2nd for N+1 | |
| Redundant AC power inputs | 1 included, 2nd for N+1 | |
| Maximum input current at 200V | 10 A | |
| Typical power dissipation | 998 Watts | |
| Maximum power dissipation | 1,633 Watts | |
| Power factor at full load | 0.95 or higher | |
| Typical heat dissipation (BTUs/hour) | 3,405 | |
| Maximum heat dissipation (BTUs/hour) | 5,572 | |
| Maximum heat dissipation (BTUs/hour) | 5,572 | |
|
|
||
| Site Preparation | Site planning
and installation included NOTE: System is customer installable. |
No |
| Rack system Depth | 696
mm/27.4 in | |
| Rack system Width | 440
mm/17.32 in | |
| Rack system height (EIA/mm) | 306
mm/12.0 in/7 U | |
| Rack system Weight (kg/lbs) maximum |
68 kg/150 lbs | |
| Pedestal system Depth | 696
mm/27.4 in | |
| Pedestal system Width | 489
mm/19.3 in | |
| Pedestal system height | 422
mm/16.7 in | |
| Pedestal system Weight (kg/lbs) maximum |
86 kg/189 lbs | |
|
| ||
| Environmental Characteristics | Acoustics (operator/bystander) at 77° F (25° C) | <6.9 Bels LwA |
| Operating Temperature (up to 5000 ft/1524 m) | 41° to 95° F (5° to 35° C) | |
| Max. rate of temperature change, operating | 30 per hour | |
| Non-operating Temperature | 5° to 35° F (-40° to 70° C) | |
| Maximum rate of temperature change,
non operating |
20° per hour | |
| Operating relative humidity | 15% to 80% RH non-condensing | |
| Non operating/storage humidity | 5% to 95% non-condensing | |
| Operating altitude above sea level | 10,000 ft (3,000 m) maximum | |
| Non-operating altitude above sea level | 15,000 ft (4,600 m) maximum | |
| NOTE:
If the N+1 power supply is ordered standalone the power supply
will ship with two cords; one that connects the system to the rack PDU and
one that enables direct connection to a wall socket. The cord that connects
the system power supply to the PDU has an IEC 19 end, which plugs into the
system power supply's IEC 20 socket, and an IEC 20 end, which plugs into
the PDU's IEC 19 socket. The localized cord that connects the system power
supply directly to the wall socket has an IEC 19 end, which plugs into the
system power supply's IEC 20 socket, and a country specific end, which plugs
into the wall socket. This localized cord is included at the distribution
site. If the N+1 power supply is ordered with the server, the additional cords will be included. |
||
|
|
||
| Regulatory Compliance | RMN | RSVLA-0405 |
| Electromagnetic interference | Complies
with FCC Rules and Regulations, Part 15 as a Class A digital device. Manufacturer's
Declaration to EN55022 Level A, VCCI Registered, Class A, Korea RLL. | |
| Safety | UL Listed, CSA Certified, TUV GS Mark compliant with EN 60950 and EN 41003 | |
| More detailed regulatory documents and certifications | http://docs.hp.com/en/hw.html | |
| | ||
| © Copyright 2009 Hewlett-Packard
Development Company, L.P.
The information contained herein is subject to change without notice. Intel and Itanium are registered trademarks or trademarks of Intel Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |