Overview
|
HP ProLiant xw25p Blade Workstation & HP Blade Workstation Client |
HP recommends Windows Vista™ Business |
![]() |
![]() |
|
42U Rack with 48 HP ProLiant xw25p Blade Workstations
|
One HP Blade Client with multiple monitors
|
| Each HP ProLiant xw25p Blade Workstation handles Office tasks, compute-intensive multitasking, roaming profile, graphical output and fast working profile restores to the HP Blade Workstation Client | |
| At A Glance |
|
|
|
| HP ProLiant xw25p Blade Workstation |
![]() |
|
42U Rack with HP ProLiant xw25p Blade Workstation
System Installed
|
| 1. | BL p-Class interconnects (2) in HP BladeSystem p-Class blade enclosure (interconnect switch shown) |
| 2. | HP ProLiant xw25p blades (8) in HP BladeSystem p-Class blade enclosure |
| 3. | HP BladeSystem p-Class 3U power enclosure with hot-plug power supplies (6) |
| At A Glance |
|
|
HP ProLiant xw25p Blade Workstation
|
||||
![]() |
||||
|
+ |
||||
|
HP BladeSystem p-Class blade enclosure
|
||||
![]() |
||||
|
+ |
||||
|
BL p-Class Interconnects
|
|
+ |
![]() |
|
Patch Panel (shown) or
Patch Panel 2 |
|
GbE Interconnect Switch (shown) or
GbE2 Interconnect Switch or CGESM Interconnect Switch (fiber or copper-based) |
|
+ |
||||
|
BL p-Class power enclosures and power supplies
|
||||
![]() |
||||
|
or
|
||||
|
HP BladeSystem p-Class 1U power enclosure and power
supplies
|
||||
![]() |
||||
|
or
|
||||
|
Facility DC
|
||||
|
HP BladeSystem p-Class power distribution (only required
with the 3U power enclosure)
|
![]() |
or
|
![]() |
or
|
![]() |
|
Mini bus bar
|
|
Bus boxes
|
||
![]() |
||||
|
Scalable bus bar
|
Dual power input kit for mini bus bar
|
|||
| Configuration Steps |
|
|
|
|
Standard Features (HP ProLiant xw25p Blade Workstation)
| Processor |
Dual AMD Opteron Model 252 processor 2.6 GHz/1 GHz - 1MB |
|
|
|
| Cache Memory | 1 MB Level 2 Cache |
|
|
|
| Chipset | AMD 8131 and 8111 chipsets |
|
|
|
| Memory | Standard | 2048 MB or 4096 MB of 2-way interleaved PC3200 DDR SDRAM running at 400MHz (depending on model) |
| Maximum | 16 GB | |
| NOTE: Memory must be installed in pairs. | ||
|
|
||
| Network Adapter | Three network adapters total: | ||
| One dual port Broadcom 5704 Gigabit NIC embedded with WOL and PXE | |||
| One 10/100 iLO NIC dedicated to management | |||
|
|
|||
| Manageability | Integrated Lights-Out (iLO) Management Advanced (ASIC on the System Board) | ||
|
|
|||
| Internal Storage | Maximum | 600 GB (internal drive cage) (2 x 300 GB Wide Ultra320, 1" drive) | |
|
|
|||
| Expansion Slots | No PCI slots all features are integrated | ||
| I/O cable connectors: | |||
| (2)USB ports, (1) video port, (1) iLO port and (1) kernel debug port | |||
| Connects to the front of the server blade for aid in 1st server blade deployment and troubleshooting | |||
| Tested USB devices (keyboard, mouse, floppy) are listed in the "Options" section of this QuickSpecs | |||
| Diagnostic Cable Connectors: | |||
| (1) iLO port and (1) kernel debug port | |||
| (2) I/O cables ship with every blade enclosure | |||
| Connects to the front of the blade for aid in troubleshooting | |||
| Graphics: | |||
| Internal NVIDIA MXM-II Quad display PCIe x16 graphics accelerator | |||
|
|
Standard Features (blade enclosure and interconnects)
| HP BladeSystem p-Class blade enclosures and ProLiant BL p-Class Interconnects | |||
| HP BladeSystem p-Class blade enclosures |
6U (10.5-inch), 19-inch wide | ||
| Holds up to 8 HP ProLiant xw25p Blade Workstations | |||
| 10 bays per blade enclosure 8 bays for blades | |||
| 2 outside bays for interconnect modules (RJ-45 Patch Panel, RJ-45 Patch Panel 2, GbE Interconnect Switch, GbE2 Interconnect Switch or CGESM Interconnect Switch) | |||
| Blades blind mate into the blade enclosure backplane for power and data connections | |||
| NOTE: Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support specific HP ProLiant xw25p blade workstation models and provide a single, physical iLO port for the enclosure. | |||
| Blade management module attached to the back of each HP BladeSystem p-Class 6U blade enclosure to report events all blades and provide asset and inventory information | |||
|
|
|||
| HP BladeSystem p-Class Power Requirements |
Redundant 200V
- 240V AC, 30 amp single-phase for NA and International Redundant 208V 30amp 3-phase 4 wire, NA Redundant 380 - 415V 20A 3-phase 5 wire, Intl Redundant -48VDC ± 10% |
||
|
|
|||
| ProLiant BL p-Class Interconnect Switch Option (Every HP BladeSystem p-Class blade enclosure requires two interconnect switches OR two RJ-45 patch panels) |
Provides up to a 32 to 1 networking cable reduction per enclosure. Each interconnect switch (two per enclosure) reduces up to sixteen internal blade network (NIC) ports to six external ports (four on a modular rear mounting interconnect module and two on the switch front panel). This provides a total of twelve external ports per blade enclosure. Only one to all twelve external ports may be used per blade enclosure. | ||
|
The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kits are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) in a Cisco infrastructure.
|
|||
|
The GbE2 Interconnect Kits (C GBE2 and F GBE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet).
|
|||
|
The GbE Interconnect Kits (C GBE and F GBE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
|
|||
| Also included (per Interconnect Switch): | |||
|
|||
|
The GbE Interconnect Kits (C GBE and F GBE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).
|
|||
| ProLiant BL Interconnect Switch Management System and Utilities: | |||
| Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and duplex mode, and more. | |||
|
|
|||
|
ProLiant BL p-Class (Two patch panels per kit) (Every BL p-Class blade enclosure requires two Interconnect switches OR two RJ-45 patch panels) |
6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U blade enclosures | ||
|
Used to pass NIC signals from all blade workstations in blade enclosure out as RJ-45 connections |
|||
|
Supports Gigabit Ethernet network adapters |
|||
|
16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 Patch Panel (32 RJ-45 connections per blade enclosure) |
|||
|
|
|||
| Required Network Cabling |
10Base-T | Categories 3, 4 or 5 UTP (100
meters) EIA/TIA-568 100-ohm STP (100 meters) |
| 100Base-TX | Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) |
|
| 1000Base-T | Category 5 UTP (100 meters) EIA/TIA-568 100-ohm STP (100 meters) |
|
| 1000Base-SX | 50/125 µm Multimode Fiber,
400 MHz/Km (500 meters) 50/125 µm Multimode Fiber, 500 MHz/Km (550 meters) 62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters) 62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters) |
|
| NOTE: For cabling
information, refer to the Web site at: http://www.compaq.com/products/servers. |
||
|
|
Standard Features (Power System and Rack Information)
| HP BladeSystem p-Class Power System and Rack Information |
NOTE:
To determine power configuration please refer to the HP BladeSystem p-Class
Overview and Planning Whitepaper and sizing tool at http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/20p/index.html. |
||
|
|
|||
| HP BladeSystem p-Class 3U Power Enclosure |
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase and three phase models available. | ||
| HP BladeSystem
p-Class 3U power enclosure provides external, shared hot-plug power. Each
three-phase power enclosure houses up to six hot-plug power supplies each
single-phase power enclosures hold up to four hot-plug power supplies to
power the xw Blade Workstations and interconnects Please use the sizing utility to determine the power needed for each configuration http://www.hp.com/go/bladesystem/powercalculator. |
|||
| NOTE: Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed. | |||
|
|
|||
| HP BladeSystem p-Class 1U Power Enclosure |
1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single phase or three phase operation. | ||
| HP BladeSystem
p-Class 1U power enclosure provides external, hot-plug power. Each 1U power
enclosure houses up to six hot-plug power supplies to power up to one Blade
Workstation enclosure, fully populated with xw Blade Workstations and interconnects. Please use the sizing utility to determine the power needed for each configuration http://www.hp.com/go/bladesystem/powercalculator. |
|||
| NOTE: Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed. | |||
|
|
|||
|
HP BladeSystem (only required with 3U power enclosures) |
In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or facility DC power) is distributed from the power enclosures to the blade enclosures through the bus bar system. Hinges attach the HP BladeSystem bus bars to the rails in a rack. The bus bars swing open from the center to enable easy rear access to the blade workstations and network cables. Power is distributed redundantly through independent A- and B-sided bus bars. | ||
| Three different power distribution solutions are available depending on the maximum number of blade enclosures planned for the rack: | |||
|
|||
| NOTE: To support a full 42U rack of HP ProLiant xw25p Blade Workstations (6 blade enclosures), two mini bus bars are needed. | |||
|
Power Enclosures Supported
|
blade enclosures Supported
|
Max. Rack Space Occupied
|
|
| Scalable Bus Bar |
1 or 2
|
up to 5
|
36U
|
| Mini Bus Bar |
1 or 2
|
up to 3
|
21U
|
| Power Bus Box |
1 Dual power input kit for mini bus bar option (364565-B21) required to support two power enclosures. NOTE: To support a full 42U rack of xw Blade Workstations, use two stacked pairs of mini bus bars. |
1
|
9U
|
|
|
|||
| Required Power Source | Two 30amp redundant
power feeds per power enclosure Connectors -NEMA receptacles (NA/Japan) NA 1-phase L6-30, 250v, 30A 3-wire NA 3-phase L15-30, 250V, 30A, 4-wire -IEC 309 Pin & Sleeve connectors (International) Intl 1-phase 250V, 32A, 3- pin (2 pole + ground) Intl 3-phase 380-415V, 32A, 5--pin (4 pole + ground) Optimized for power cabling from bottom and network cabling from top |
||
|
|
Standard Features (HP ProLiant xw25p Blade Workstation)
| ProLiant Essentials Foundation Pack Software for ProLiant Blades | ProLiant Essentials Rapid Deployment Pack | Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all blades. RDP includes the Altiris Deployment Solution. Every RDP CD includes 10-node trial licenses for evaluation purposes. RDP requires a license for each blade deployed and is available for purchase with blades. For more information, visit http://www.hp.com/servers/rdp. | |
| HP Systems Insight Manager | HP Systems Insight Manager (HP SIM) help maximize system uptime and performance and reduce system maintenance costs by providing proactive notification of problems before those problems result in unplanned downtime or reduced productivity. HP SIM is easy to set up to work with the Insight Management Agents, integrated Light-Out and Remote Insight Light-Out Edition, and Version Control Agents to deliver robust fault, configuration, and asset management as well as remote administration. With HP Systems Insight Manager customers will also be able to take advantage of role-based security; the ability to manage ProLiant, Integrity, and HP9000 systems; and plug-ins for storage, client, printer, and power management as well as blade rapid deployment, performance management, and workload management. For more details on HP Systems Insight Manager visit http://www.hp.com/go/hpsim. | ||
| Management Agents | The Management Agents form the foundation for HP's Intelligent Manageability strategy. They provide direct, browser-based access to in-depth instrumentation built into HP Blade Workstations and clients, and send alerts to HP Systems Insight Manager and other enterprise management applications in case of subsystem or environmental failures. For additional information about the Management Agents and other management products from HP, please visit the management Web site at http://www.hp.com/servers/manage. | ||
| Subscriber's Choice | Subscriber's Choice Driver
and Support Alerts/Notifications is a web-based email subscription service
that provides software and driver change notifications for HP products.
Sign up at http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. |
||
| ROMPaq, support software,
and configuration utilities |
The latest software, drivers, and firmware fully optimized and tested for your workstation blade and options is downloadable from Software and Drivers download pages, linked from http://www.hp.com/go/support. | ||
| Insight Diagnostics Offline Edition | The most advanced configuration analysis, reporting and troubleshooting utilities used by HP and at your fingertips, available in documentation and diagnostics CD that ships with the system. | ||
|
|
|||
| OS Support | Microsoft® Windows®
XP Professional Blade PC Edition
NOTE: For a more complete and up-to-date
listing of supported OSs and versions, please visit our OS Support Matrix
at: http://www.hp.com/go/supportos. |
|
|
|
| Intelligent Manageability | Integrated Lights-Out Advanced (iLO) |
| Graphical Remote Console * Virtual CD-ROM* Virtual Floppy * Virtual Power Button Control Dedicated LAN Connectivity Automatic IP Configuration via DHCP/DNS/WINS Industry Standard 128-bit Secure Sockets Layer (SSL) Security IML and iLO Event Logging Support for 12 user accounts with customizable access privileges |
|
| HP Systems Insight Manager Redundant ROM Remote Flash ROM Redundant Power Supply Utility Advanced Configuration and Power Interface (ACPI) compliant, does not support sleep states S1 and S3 Integrated Management Log (IML) Network adapter teaming set-up utility |
|
| *NOTE: Advanced features such as Graphical Remote Console and Virtual Floppy are included with the blade. | |
|
|
|
| Availability | Power redundancy: Redundant
AC feeds into power enclosures, redundant DC feeds from power enclosure
to blade enclosures, N + N redundant power supplies Two hot-plug SCSI hard drive bays and integrated RAID (Smart Array 5i Plus) on every blade (Battery-backed write cache is optional.) Redundant ROM on each blade ECC Memory Network adapter teaming (network fault tolerance, transmit load balancing, switch-assisted load balancing) Interconnects Switch Availability |
|
|
|
|
|
| Security | Power-on password Administrator's password Integrated Lights-Out has 12 customizable user accounts and SSL encryption Integrated Lights-Out can be disabled via a Global Setting Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and IP address restriction |
| *NOTE: CGESM and GbE2 Interconnect Switch only | |
|
|
|
| Minimum Rack Requirements | Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria: |
|
|
| NOTE: If using Compaq 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are required. | |
|
|
|
| Rack Airflow Requirements | Rack 10000 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted blades. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with blades using the latest processors. |
| CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: | |
|
|
| CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. | |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the blade, or to the blade documentation located in the Support section at the following URL: http://www.hp.com/servers/bl25p. | |
|
|
|
| Service and Support |
Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers. In addition 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services. NOTE: Workstation Blade Limited Warranty
includes 3 year Parts, 3 year Labor, 3-year on-site support. Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including:
NOTE: Support information for the Blade
Workstation is available at the following web page: http://www.hp.com/support/xw25p
|
|
|
Configuration Information Factory Integrated Models (North America& EMEA)
| ProLiant xw25p
Blade Workstation 2.6 GHz-1 MB, 4 GB (2P), 146 GB 390294-B21 |
Processor(s) | (1) AMD Opteron Model 252 2.6 GHz standard (up to 2 supported) | |
| Cache Memory | 1 MB Level 2 writeback per processor | ||
| Memory | 4 GB (Standard) to 16 GB (Maximum) of 2-way interleaved capable PC3200 DDR SDRAM running at 400MHz (4x 1 GB) | ||
| Network Adapter | Two Gigabit NICs (embedded)
with WOL and PXE One additional 10/100 NIC dedicated to iLO Management |
||
| Storage Controller | Smart Array 6i Controller (integrated on system board) | ||
| Hard Drives | 146 GB Ultra320 SCSI 10K RPM | ||
| Internal Storage | Up to 2 Ultra320 SCSI drives | ||
| Optical Drive | None | ||
| Form Factor | Plugs vertically into HP BladeSystem p-Class blade enclosure | ||
|
|
|||
| ProLiant xw25p
Blade Workstation 2.6Ghz-1MB, 2GB (2P), 72 GB 390293-B21 |
Processor(s) | (1) AMD Opteron Model 252 2.6 GHz standard (up to 2 supported) |
| Cache Memory | 1 MB Level 2 writeback per processor | |
| Memory | 2 GB (Standard) to 16 GB (Maximum) of 2-way interleaved capable PC3200 DDR SDRAM running at 400MHz (4x512 MB) | |
| Network Adapter | Two Gigabit NICs (embedded)
with WOL and PXE One additional 10/100 NIC dedicated to iLO Management |
|
| Storage Controller | Smart Array 6i Controller (integrated on system board) | |
| Hard Drives | 72 GB Ultra320 SCSI 10K RPM disk | |
| Internal Storage | Up to 2 Ultra320 SCSI drives | |
| Optical Drive | None | |
| Form Factor | Plugs vertically into HP BladeSystem p-Class blade enclosure |
|
|
Options
| ProLiant Essentials
Value Pack Software |
Rapid Deployment Pack, 10 User, V1.x |
269817-B21
|
| NOTE: This license
allows 10 blades to be managed and deployed via the Deployment Server. NOTE: Not necessary if you purchase the blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21. NOTE: Rapid Deployment pack is now available in Linux only environments. |
||
| Rapid Deployment Pack, 10 User, V1.x (Japan) |
269817-291
|
|
| NOTE: This license
allows 10 blades to be managed and deployed via the Deployment Server. NOTE: Not necessary if you purchase the blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21. NOTE: Rapid Deployment pack is now available in Linux only environments. |
||
| Rapid Deployment Pack, 1 User, V1.x |
267196-B21
|
|
| NOTE: This license
allows 1 blade to be managed and deployed via the Deployment Server. NOTE: Not necessary if you purchase the blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21. NOTE: Rapid Deployment pack is now available in Linux only environments. |
||
| Rapid Deployment Pack, 1 User, V1.x (Japan) |
267196-291
|
|
| NOTE: This license
allows 1 blade to be managed and deployed via the Deployment Server. NOTE: Not necessary if you purchase the blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21. NOTE: Rapid Deployment pack is now available in Linux only environments. |
||
| Flexible Quantity License Kit |
302127-B21
|
|
| License-Only - for use with a Master License Agreement |
302128-B21
|
|
|
|
||
| Memory (SDRAM DIMMs) |
4GB of Advanced ECC PC3200 DDR-400 SDRAM DIMM Memory Kit (2 x 2 GB) |
379300-B21
|
| 2GB of Advanced ECC PC3200 DDR-400 SDRAM DIMM Memory Kit (2 x 1 GB) |
376639-B21
|
|
| 1GB of Advanced ECC PC3200 DDR-400 SDRAM DIMM Memory Kit (2 x 512 MB) |
376638-B21
|
|
|
|
||
| Hard Drives | Ultra320 SCSI - Universal Hot Plug | |
| 300 GB 10,000 rpm U320 Universal Hard Drive (1") |
350964-B22
|
|
| 146.8 GB 10,000 rpm U320 Universal Hard Drive (1") |
286716-B22
|
|
| 72.8 GB 10,000 rpm U320 Universal Hard Drive (1") |
286714-B22
|
|
| 72.8 GB 15,000 rpm U320 Universal Hard Drive (1") |
286778-B22
|
|
| 146.8 GB 15,000 rpm U320 Universal Hard Drive (1") |
347708-B22
|
|
| 36.4 GB 15,000 rpm U320 Universal Hard Drive (1") |
286776-B22
|
|
|
|
||
| HP BladeSystem p-Class blade enclosures |
HP BladeSystem p-Class blade
enclosure with enhanced backplane components and the HP BladeSystem Management
Suite NOTE: Includes a HP BladeSystem p-Class blade enclosure with enhanced backplane components, a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM). NOTE: The HP ProLiant xw25p Blade Workstation does not currently support PMP. Future support is planned. |
380625-B22
|
| HP BladeSystem p-Class blade enclosure (ProLiant Essentials Rapid Deployment Pack Trial) |
243564-B21
|
|
| HP BladeSystem p-Class blade enclosure (8 ProLiant Essentials Rapid Deployment Pack Licenses) |
281404-B21
|
|
| HP BladeSystem p-Class blade enclosure with enhanced backplane components (ProLiant Essentials Rapid Deployment Pack Trial) |
243564-B22
|
|
| HP BladeSystem p-Class blade
enclosure with enhanced backplane components (8 ProLiant Essentials Rapid
Deployment Licenses) NOTE: HP BladeSystem p-Class Enhanced blade enclosures with enhanced backplane components may be required depending on which HP ProLiant xw25p Blade Workstation model is selected. For additional information regarding blade enclosure Compatibility, please visit the following URL: http://www.hp.com/go/bladesystem/enclosure/compatibility |
281404-B22
|
|
| HP BladeSystem p-Class blade
enclosure Upgrade Kit (option) NOTE: blade enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure. |
354100-B21
|
|
|
|
||
| HP BladeSystem
p-Class Interconnects |
ProLiant BL p-Class RJ-45 Patch Panel 2 with Fibre pass-through (pair) (required for FC connectivity) |
306465-B21
|
| NOTE: Only one interconnect kit required per blade enclosure. | ||
| ProLiant BL p-Class RJ-45 Patch Panel (pair) |
230766-B21
|
|
| NOTE: Only one interconnect kit required per blade enclosure. | ||
| ProLiant BL p-Class C GBE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadT2 Interconnect Modules) |
283192-B21
|
|
| NOTE: Only one interconnect kit required per blade enclosure. | ||
| ProLiant BL p-Class F GBE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadSX Interconnect Modules) |
283193-B21
|
|
| NOTE: Only one interconnect kit required per blade enclosure. | ||
| Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit only |
378926-B21
|
|
| NOTE: Two CGESM interconnect kits required per blade enclosure. | ||
| Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit (populated with two RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules |
378927-B21
|
|
| NOTE: Two CGESM interconnect kits required per blade enclosure. | ||
| Cisco RJ-45 10/100/1000 T/TX/T SFP Module |
378928-B21
|
|
| ProLiant BL p-Class C GBE Interconnect Kit (with pair of GbE Interconnect Switches and two QuadT Interconnect Modules) |
249655-B21
|
|
| NOTE: Only one
interconnect kit required per blade enclosure. NOTE: The GbE Interconnect Switch supports blade NIC speeds to 100 Mbps. It is recommended that a patch panel or GbE2 Interconnect Switch option be used if blade NIC speeds to 1000 Mbps are required. NOTE: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit. |
||
| ProLiant BL p-Class F GBE Interconnect Kit (with pair of GbE Interconnect Switches and two DualTSX Interconnect Modules) |
279720-B21
|
|
| NOTE: Only one
interconnect kit required per blade enclosure. NOTE: The GbE Interconnect Switch supports NIC speeds to 100 Mbps. It is recommended that a patch panel option be used if blade NIC speeds to 1000 Mbps are required. NOTE: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit. |
||
|
|
||
| HP BladeSystem
p-Class Interconnects |
NOTE: Use p-Class
sizing tool to help determine power configuration: http://h30099.www3.hp.com/configurator/powercalcs.asp |
|
| Single Phase 3U Power Enclosure
with 4 power supplies (NA/JPN) (Single Phase 3U Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) |
239162-001
|
|
| Single Phase 3U Power Enclosure
with 4 power supplies (Int'l) (Single Phase 3UPower Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit) |
239162-421
|
|
| 3 Phase 3U Power Enclosure with
6 power supplies (NA/JPN) (3 Phase 3U Power Enclosure holds a maximum of 6 power supplies; no need to order additional power supplies with this option kit) |
230769-001
|
|
| 3 Phase 3U Power Enclosure with
6 power supplies (Int'l) (3 Phase 3U Power Enclosure holds a maximum of 6 power supplies; no need to order additional power supplies with this option kit) |
230769-421
|
|
| Single 3U Phase Power Enclosure
(empty) (NA/JPN) (Holds up to 4 power supplies; power supplies are not included in this kit) |
231710-001
|
|
| Single 3U Phase Power Enclosure
(empty) (Int'l) (Holds up to 4 power supplies; power supplies are not included in this kit) |
231710-421
|
|
| 3 Phase 3U Power Enclosure (empty)
(NA/JPN) (Holds up to 6 power supplies; power supplies are not included in this kit) |
231709-001
|
|
| 3 Phase 3U Power Enclosure (empty)
(Int'l) (Holds up to 6 power supplies; power supplies are not included in this kit) |
231709-421
|
|
| Single 3U Power Supply |
239161-B21
|
|
| 1U Power Enclosure with six power supplies |
378284-B21
|
|
| 1U Power Enclosure with two power supplies |
380314-B21
|
|
| Single 1U Power Supply |
380312-B21
|
|
| Facility DC Power Connection |
240563-B21
|
|
|
|
||
|
Power Distribution (only required with 3U power enclosures) |
HP BladeSystem p-Class Scalable Bus Bar |
240560-B21
|
| HP BladeSystem p-Class Mini Bus Bar |
240559-B21
|
|
| HP BladeSystem p-Class Bus Power Box |
240562-B21
|
|
| Dual Power Input Kit for Mini Bus Bar |
364565-B21
|
|
| HP Modular Distribution Unit 40 Amp (NA/JPN) |
252663-D75
|
|
| HP Modular Distribution Unit 40 Amp (Int'l) |
252663-B34
|
|
| HP Modular Distribution Unit 32 Amp (Int'l) |
252662 -B33
|
|
| HP Modular Distribution Unit
24 Amp (NA/JPN) NOTE: The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-class 1U power enclosure. |
252663-D74
|
|
| HP BladeSystem Power Extension
Kit NOTE: This kit is specifically for HP BladeSystem p-Class customers who want to upgrade their standard blade enclosures to enhanced blade enclosures and would like to install an additional, redundant 3U power enclosure above the blade enclosures rather than below them. The option kit consists of two extension cable assemblies - one for each side (A and B). |
381686-B21
|
|
|
|
||
|
Other Options |
HP BladeSystem p-Class Diagnostic
Station NOTE: The Diagnostic Station allows access to the blade and the BL p-Class interconnect switch outside of the enclosure. The option provides power and a data interface so that "offline" upgrade and diagnostic functions may be performed. |
230743-B21
|
| HP BladeSystem p-Class Power
Enclosure Shipping Bracket Option Kit NOTE: Used to secure one power enclosure in a rack when moving |
365044-B21
|
|
|
|
||
|
USB Options |
USB 1.44 MB External Diskette Drive (Carbonite) |
DC141B
|
| USB Easy Access Keyboard |
267146-XX8
|
|
| USB Easy Access Keyboard (Carbonite) |
DC168B#
|
|
| USB 2-Button Optical Mouse (Carbonite) |
DC172B
|
|
| USB Optical Scroll Mouse (Carbonite) |
DD441B
|
|
| 256MB HP Drive Key II (USB 2.0) |
PH657A
|
|
|
USB Easy Access Keyboard (Carbonite/Silver)
Country Key Code |
|||
|
Dash #
|
Description
|
Dash#
|
Description
|
|
A2M
|
ICELAND
|
ABT
|
HE
|
|
AB0
|
TAWA
|
ABU
|
UK
|
|
AB1
|
KOR
|
ABV
|
ARA
|
|
AB2
|
PRC
|
ABX
|
FIN
|
|
AB6
|
FRA
|
ABY
|
DEN
|
|
AB7
|
GRK
|
ABZ
|
ITL
|
|
AB8
|
TURK
|
AC0
|
BEL
|
|
AB9
|
PORT
|
AC4
|
BRZ
|
|
ABA
|
US
|
ACB
|
RUSS
|
|
ABB
|
EURO
|
AKB
|
CZE
|
|
ABC
|
FCAN
|
AKC
|
HUNG
|
|
ABD
|
GR
|
AKD
|
POL
|
|
ABE
|
SP
|
AKL
|
THAI
|
|
ABF
|
FR
|
AKN
|
BHCSY
|
|
ABH
|
NL
|
AKR
|
SLOV
|
|
ABJ
|
Japan
|
ARK
|
ICELAND
|
|
ABM
|
LA
|
B15
|
KAZ
|
|
ABN
|
NOR
|
UUZ
|
SWISS
|
|
ABS
|
SW
|
||
|
|
|||
|
HP Rack 5000 Series |
HP 5642 Rack - Unassembled |
358254-B21
|
|
|
||
|
Rack Options for Rack 5000 Series |
Stabilizer Kit for 5642 Rack
(Graphite Carbon) NOTE: The stabilizing kit is used to prevent rack from tipping over. |
374493-B21
|
| Baying Kit for 5642 Rack (Graphite
Carbon) NOTE: The baying kit is used to join two or more HP 5642 racks. |
374499-B21
|
|
|
|
||
|
Rack 10000 Series |
Rack, HP Infrastructure 42U (HV) |
379005-001
|
| Rack, HP Infrastructure 42U (LV) |
379006-001
|
|
| HP Rack 10842 (42U) - Pallet |
257415-B21
|
|
| HP Rack 10842 (42U) - Shock Pallet |
257415-B22
|
|
| HP S10614 (14U) Rack Cabinet - Shock Pallet |
292302-B22
|
|
| HP Rack 10647 (47U) Cabinet - Pallet |
245160-B21
|
|
| HP Rack 10647 (47U) Cabinet - Crated |
245160-B23
|
|
| HP Rack 10642 (42U) Cabinet - Pallet |
245161-B21
|
|
| HP Rack 10642 (42U) Cabinet - Shock Pallet |
245161-B22
|
|
| HP Rack 10642 (42U) Cabinet - Crated |
245161-B23
|
|
| HP Rack 10636 (36U) Cabinet - Pallet |
245162-B21
|
|
| HP Rack 10636 (36U) Cabinet - Shock Pallet |
245162-B22
|
|
| HP Rack 10636 (36U) Cabinet - Crate |
245162-B23
|
|
| HP Rack 10622 (22U) Cabinet - Pallet |
245163-B21
|
|
| HP Rack 10622 (22U) Cabinet - Shock Pallet |
245163-B22
|
|
| HP Rack 10622 (22U) Cabinet - Crated |
245163-B23
|
|
| NOTE: -B21 (pallet)
used to ship empty racks shipped on a truck -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipments of empty racks Not all HP equipment is qualified to be shipped in the Rack 10000 series. |
||
| NOTE: Please
see the Rack 10000 QuickSpecs for Technical Specifications such as height,
width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.html (Worldwide) http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html (North America) |
||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html | ||
|
|
||
|
Rack Options for HP Rack 10000 Series |
HP Light kit for 10000 series rack |
361589-B21
|
| HP Plinth kit for 10000 series rack |
251960-B21
|
|
| 42U Side Panel - Graphite Metallic |
246099-B21
|
|
| 36U Side Panel - Graphite Metallic |
246102-B21
|
|
| 47U Side Panel - Graphite Metallic |
255486-B21
|
|
| NOTE: For additional information regarding Rack Options, please see the fo |