Overview
|
HP Dynamic Smart Cooling |
|
DSC Base Station
|
![]() |
|
|
|
The new HP Dynamic Smart Cooling (DSC) technology helps you tackle one of the most critical issues in today's data centers - power and cooling. DSC will enable you to change data center energy costs from a fixed to a variable cost, significantly increase your IT scaling headroom, and ensure complete confidence that you're running a much more efficient data center - helping you drive towards a more adaptive infrastructure. Why Dynamic Smart Cooling?
HP Dynamic Smart Cooling bridges the legacy gap between IT and facilities managers for significant cost savings to create a more adaptive infrastructure. Typically, IT equipment has simply existed within the data center, with power and cooling capacity increasingly limiting the ability to efficiently deploy new technologies. For the first time, Dynamic Smart Cooling - the latest HP innovation produced from over a decade of research efforts - enables the equipment to interact with the facilities that support the data center, driving maximum efficiency. NOTE: For more information please see: |
|
|
| At a Glance |
|
HP Dynamic Smart Cooling includes a DSC Energy Manager Control Node, DSC Base Stations and DSC Intake Sensors. Additionally, DSC Exhaust Sensors may be added to enhance DSC's capabilities by allowing the detection of no flow, reverse flow or low load conditions. For additional information please visit: http://www.hp.com/go/dsc and http://www.hp.com/go/btc Protected by HP Services and a three-year, on-site limited global warranty. Certain restrictions and exclusions apply. |
|
|
Product Features
| HP DSC Energy Manager Control Node |
As the brains of the operation, the DSC Energy Manager Control Node is a HP ProLiant DL380 G5 running Microsoft Windows Server 2003, Microsoft SQL Server 2005 and HP DSC Energy Management software. The DSC Energy Manager Control Node communicates with the facility's Computer Room Air Conditioners to provide only the amount of cooling required at a point in time, and no more. | ||
|
| |||
| HP DSC Base Station |
HP DSC Base Stations are assigned to individual racks and collect temperature data from DSC Intake and Exhaust Sensors associated with that rack. The DSC Base Station then reports that information every 15 seconds to the DSC Energy Manager Control Node. |
|
|
|
||
| HP DSC Intake & Exhaust Sensors |
HP DSC Intake & Exhaust Sensors are arrays of thermal sensors. DSC Intake Sensors are installed in front of a rack, while the optional DSC Exhaust Sensors are installed at the rear of the rack. The intake sensors allow DSC to determine if the air going into a rack is cool enough for the rack's load. The optional exhaust sensors extend DSC capabilities by allowing DSC to detect no flow, reverse flow or low load conditions. | ||
|
|
Service & Support
| Deployment Service |
The required deployment service for HP Dynamic Smart Cooling is ordered via part number HF801A1 and requires a price to be entered since this is a custom bid service. The price is available in the final quote that was provided to the customer and must be entered at the time the order was placed. |
|
|
|
| Assessment Service |
The HP DSC Thermal Assessment is ordered, and invoiced, separately under part number HA536A1. This provides an analysis comparing industry/HP best practices to the customer's current data center environment and readiness for Dynamic Smart Cooling. In addition, HP will perform 3D modeling of the entire data center supply and return air flows and will provide a written report that includes observations, thermal model results, DSC readiness results, and recommendations for improvement. |
|
|
|
| Service and Support |
This product is covered by a global limited warranty and supported by HP Services and a worldwide network of service providers. Hardware diagnostic support and repair is available for three years from date of purchase. Additional support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services or customized service agreements. NOTE: DSC Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support. This warranty supports the DSC Energy Manager Control Node, DSC Base Station and DSC Intake & Exhaust Sensors. HP DSC Energy Management Control Software includes 1 year next business day support. HP services provide continuous care and support expertise with committed response designed to meet your IT and business needs. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a HP Dynamic Smart Cooling support offer to help you speedily deploy and maximize system uptime. Available Support Upgrades:
|
||
|
|
Models
| NOTE: Each HP DSC Base Station supports one Intake Sensor Array and typically one base station is placed at every second rack in a data center. Universal sensors are for non-HP racks. | ||
| HP DSC Configuration | ||
| NOTE: Determine quantity of HP DSC Base Station and Intake Sensor Arrays to purchase and choose the HP DSC Energy Manager Control Node that supports at least that quantity. | ||
| Required Options (one of the following from each category unless otherwise noted) | ||
| HP DSC Energy Manager Control Nodes | HP DSC Energy Manager Control Node Unlimited (1000 base stations) |
AJ350A
|
| HP DSC Energy Manager Control Node Large (500 base stations) |
AJ353A
|
|
| HP DSC Energy Manager Control Node Medium (250 base stations) |
AJ352A
|
|
| HP DSC Energy Manager Control Node Small (125 base stations) |
AJ351A
|
|
| NOTE: Order only one DSC Energy Manager Control Node per managed area. A managed area is typically one room of a data center. | ||
| HP DSC Base Stations | HP DSC Base Station. Single |
AH979A
|
| HP DSC Base Station. Bulk |
AH980A
|
|
| NOTE: Bulk packs contain 20 base stations. | ||
| HP DSC Intake Sensors | HP DSC Intake Sensors (Unv.). Single |
AH981A
|
| HP DSC Intake Sensors (Universal). Bulk |
AH982A
|
|
| HP DSC Intake Sensors (10k). Single |
AH983A
|
|
| HP DSC Intake Sensors (10k). Bulk |
AH984A
|
|
| NOTE: HP DSC Intake
Sensors (10k) are only for HP 10k G1 & G2 42U & 47U racks. All other
racks use the DSC Intake Sensors (Universal). NOTE: DSC Exhaust Sensors are also available to extend the capabilities of DSC NOTE: Order the same quantity of sensors as base stations. Bulk packs contain 20 units. |
||
| HP DSC Exhaust Sensors | HP DSC Exhaust Sensors, Single |
AH985A
|
| HP DSC Exhaust Sensors, Bulk |
AH986A
|
|
| NOTE: Exhaust sensors extend the capabilities of DSC by allowing it to detect no flow, reverse flow and low load conditions. | ||
|
|
Related Options
| HP Rack 10000 G2 Series (Graphite Metallic) | 10642 G2 (42U) Rack Cabinet Pallet |
AF001A
|
| 10642 G2 (42U) Rack Cabinet Shock Pallet |
AF002A
|
|
| 10642 G2 (42U) Rack Cabinet Crated |
AF003A
|
|
| 10642 G2 (42U) Rack Cabinet, with Extension Shock Pallet |
AF004A
|
|
| 10642 G2 (42U) Rack Shock Pallet- for field racking (NA only) |
AF007A
|
|
| 10636 G2 (36U) Rack Cabinet Shock Pallet |
AF011A
|
|
| 10636 G2 (36U) Rack Cabinet Crated |
AF012A
|
|
| 10636 G2 (36U) Rack Cabinet, with Extension Shock Pallet |
AF013A
|
|
| 10636 G2 (36U) Rack Cabinet, without door Shock Pallet |
AF014A
|
|
| 10647 G2 (47U) Rack Cabinet Pallet |
AF031A
|
|
| 10842 G2 (42U) Rack Cabinet Shock |
AF042A
|
|
| 10842 G2 (42U) Rack Cabinet Pallet |
AF041A
|
|
| NOTE: Please see
the Rack 10000 G2 QuickSpecs for additional part numbers and Technical Specifications
such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html (Worldwide) NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. |
||
|
|
||
| Service and Support Offerings (HP Care Pack Services) | NOTE: It is highly recommended that the HP DSC Base Stations and Energy Managers have the same support level. | |
| For the HP DSC Energy Managers, HP support services are mandatory. Customers must choose from one of the HP Care Pack services below: | ||
| HP DSC Energy Manager Services | ||
| HP 1y SW Support |
HA106A1#4YU
|
|
| HP 1y Support Plus SVC |
HA109A1#4YU
|
|
| HP 1y Support Plus 24 SVC |
HA110A1#4YU
|
|
| HP 3y SW Support |
HA106A3#4YU
|
|
| HP 3y Support Plus SVC |
HA109A3#4YU
|
|
| HP 3y Support Plus 24 SVC |
HA110A3#4YU
|
|
|
|
Technical Specifications
|
DSC Sensor Arrays & Base Station |
|
DSC Intake Sensor for HP 10k Series Racks
|
![]() |
| NOTE: DSC Intake Sensor Arrays for HP 10k Series Racks are mounted at the front of the rack. Each array consists of five thermal sensors. |
|
|
|
DSC Intake Sensors (Universal)
|
![]() |
| NOTE: DSC Universal Intake Sensor Arrays work with many third party non-HP racks. Like the arrays for the HP 10k Series racks, they are installed at the front of the rack and consist of five thermal sensors per array. |
|
|
|
DSC Exhaust Sensors
|
![]() |
| NOTE: DSC Exhaust Sensors mount at the rear of racks, and like the intake sensors, consist of five thermal sensors. Exhaust sensors are not required for DSC to function properly. They are an option that extends the capabilities of DSC to enable the DSC Energy Manager to detect no flow, reverse flow or low load conditions in racks equipped with the exhaust sensors. |
|
|
|
DSC Base Station Front Panel View
|
![]() |
|
|
|
DSC Base Station Rear Panel View
|
![]() |
| Each DSC Base Station supports up to two sensor arrays: one intake sensor and one exhaust sensor. Only one base station is assigned per monitored rack. Typically, every second rack in a data center would be monitored and have a base station assigned to it. |
|
|
| HP DSC Base Station | Shipping Dimensions | Height | 4.0in (102 mm) |
| Width | 8.13 (207 mm) | ||
| Depth | 10.63in (270 mm) | ||
| Weight | Unboxed | 2.2 lb (1.0 Kg) | |
| Shipping | 2.85 lb (1.3 Kg) | ||
| Temperature Range | Operating | 50° to 158° F (10° to 70° C) | |
| Non-Operating | -4° to 158° F (-20° to 70° C) | ||
| Relative Humidity (non-condensing) |
Operating | 10% to 90% | |
| Non-Operating | 5% to 95% | ||
| Wet Bulb Temperature | Non-Operating | 101.7° F (38.7° C) | |
|
|
|||
| Power | Input Characteristics | Input voltage | 90 - 264Vrms |
| Input frequency | 47 - 63Hz | ||
| Input current | 1.5A at 100VAC | ||
| Inrush Current | 100A at 240VAC | ||
| Leakage Current | Less than 3.5mA at 250VAC/60Hz | ||
| Power Supply | Input Power Connection | C5 | |
| Type | On-board AC/DC | ||
|
|
|||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. |
|
|
|
|||
|
© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |