|
|
Overview
|
HP Cluster Platform Workgroup System Tower |
![]() |
![]() |
||
|
HP BladeSystem c3000 Enclosure Tower
Front View |
HP BladeSystem c3000 Enclosure Tower Rear View | ||
| 1. | Device Bays 1 thru 8 | 1. | Local KVM interface* |
| 2. | Enclosure DVD Drive | 2. | Interconnect Bay 1 |
| 3. | Standby Onboard Administrator (reserved for Future)* | 3. | Active Cool Fans |
| 4. | Insight Display | 4. | Interconnect Bay 2* |
| 5. | Active Onboard Administrator | 5. | Enclosure Up-link and Service Port |
| 6. | Enclosure Down-link | ||
| 7. | iLO/Onboard Administrator Port | ||
| 8. | iLO/Onboard Administrator Port 2 (reserved for future)* | ||
| 9. | Power Supplies | ||
| 10. | Interconnect Bays 3 & 4 | ||
| * Not currently used in the HP Cluster Platform Workgroup System configurations. | |||
|
|
|||
| At A Glance |
HP Cluster Platform Workgroup System is available from HP Sales Representatives
and HPC-Certified Resellers, utilizing Cluster Platform Express configurators.
Quotes can be requested by submitting a form available at the following
web site: http://www.hp.com/go/cp-express.
Basic Architecture Components: Networks
Basic Architecture Components: Infrastructure
Basic Architecture Components: Software
|
|
|
| Summary Table of Cluster Platform Workgroup System Tower Options |
| Cluster Platform Workgroup System | Control node |
Compute node |
High Performance Cluster interconnect |
| HP ProLiant BL460c G6 * HP ProLiant BL280c G6 * HP ProLiant BL2x220c G5 *w/ optional SB40c for more direct-attached storage |
HP ProLiant BL460c G6 HP ProLiant BL280c G6 HP ProLiant BL2x220c G5 |
InfiniBand, or use cluster's Gigabit Ethernet admin network | |
| HP ProLiant BL465c G5 w/ optional SB40c for more direct-attached storage |
HP ProLiant BL465c G5 |
|
|
Standard Features
| Packaging for HP Cluster Platform Workgroup System |
|
| The CP Workgroup System Tower consists of one HP BladeSystem c3000 Tower enclosure with one OA, one DVD drive, one GbE2c Ethernet Switch blade, one control node and minimum of two compute nodes, fans and power supplies (quantity depending on the actual configuration of the server blades). A keyboard/monitor (not included) will be needed to access the enclosure and blades for initial setup | |
| Delivered on shock resistant pallet | |
| All hardware parts (servers, switches, etc) are installed in the enclosure | |
| Fully pre-wired and factory integrated | |
|
|
|
| HP Cluster Platforms Workgroup System with HP ProLiant BL460c G6 Compute Nodes | ||
| Control Node | HP ProLiant BL460c G6 server
blade NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/12534.html |
|
| Choose Processor Option |
All currently shipping processors for each control node are available. Select one or two processors |
|
| Memory Option | HP ProLiant BL460c G6 is available with DDR3 Unbuffered or Registered DIMMs. Maximum memory is 96GB per node. | |
| DVD Option | Covered in the enclosure configuration | |
| Disk Option | One disk minimum for control node, up to two HP SATA or HP SAS Small Form Factor drives can be configured. Optionally, SB40c storage blade can be added for more direct-attached storage. | |
| PCI - I/O Options | HP ProLiant BL460c G6 server blade has two multifunctional 10 Gigabit NICs integrated. When InfiniBand interconnect is selected, a PCI-Express InfiniBand Mezzanine card must be added, and the IB driver software right-to-use license must be added. A host-based subnet manager must also be added. | |
| Redundant Power Supply | Covered in the enclosure configuration | |
|
|
||
| Compute Node | Specify Number of Nodes | Select number of HP ProLiant
BL460c G6 Server. Total compute nodes cannot exceed 7 nodes. NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/12534.html |
| Memory Options |
HP ProLiant BL460c G6 is available with DDR3 Unbuffered or Registered DIMMs. Maximum memory is 96GB per node. |
|
| DVD Drive Options | Covered in the enclosure configuration | |
| Disk Options | One or two HP SATA or HP SAS Small Form Factor Drives. | |
| PCI - I/O Options | HP ProLiant BL460c server blade has two multifunctional 10 Gigabit NICs integrated. When InfiniBand interconnect is selected, a PCI-Express InfiniBand Mezzanine card must be added, and the IB driver software right-to-use license must be added. | |
| Redundant Power Supply | Covered in the enclosure configuration | |
|
|
||
| HP Cluster Platforms Workgroup System with HP ProLiant BL280c G6 Compute Nodes | ||
| Control Node | HP ProLiant BL280c G6 server
blade NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/12534.html |
|
| Choose Processor Option |
All currently shipping processors for each control node are available. Select one or two processors |
|
| Memory Option | HP ProLiant BL280c G6 is available with DDR3 memory. Maximum memory is 96GB per node. | |
| DVD Option | Covered in the enclosure configuration | |
| Disk Option | One disk minimum for control node, up to two NHP SATA or SAS drives can be configured. Optionally, SB40c storage blade can be added for more direct-attached storage. | |
| PCI - I/O Options | HP ProLiant BL280c G6 server blade has two multifunctional Gigabit NICs integrated. When InfiniBand interconnect is selected, a PCI-Express InfiniBand Mezzanine card must be added, and the IB driver software right-to-use license must be added. A host-based subnet manager must also be added. | |
| Redundant Power Supply | Covered in the enclosure configuration | |
|
|
||
| Compute Node | Specify Number of Nodes | Select number of HP ProLiant
BL280c G6 Server. Total compute nodes cannot exceed 7 nodes. NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/12534.html |
| Memory Options |
HP ProLiant BL280c G6 is available with DDR3 memory. Maximum memory is 96GB per node. |
|
| DVD Drive Options | Covered in the enclosure configuration | |
| Disk Options | One or two NHP SATA or SAS drives. | |
| PCI - I/O Options | HP ProLiant BL280c G6 server blade has two multifunctional Gigabit NICs integrated. When InfiniBand interconnect is selected, a PCI-Express InfiniBand Mezzanine card must be added, and the IB driver software right-to-use license must be added. | |
| Redundant Power Supply | Covered in the enclosure configuration | |
|
|
||
| HP Cluster Platforms Workgroup System with HP ProLiant BL2x220c G5 Compute Nodes | ||
| Control Node | HP ProLiant BL2x220c G5 server
blade. This is a double-dense blade made of two 2-socket servers. NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/12534.html |
|
| Choose Processor Option |
All currently shipping processors for each control node are available. Select one or two processors per server (two or four per blade/node). |
|
| Memory Option | HP ProLiant BL2x220c G5 is available with PC2-5300 DDR2 memory. Maximum memory is 32GB per server (64GB per blade). | |
| DVD Option | Covered in the enclosure configuration | |
| Disk Option | One disk minimum per server for control node, up to one NHP SATA drive per server can be configured. | |
| PCI - I/O Options | HP ProLiant BL2x220c G5 server blade has two multifunctional Gigabit NICs integrated per server. When InfiniBand interconnect is selected, a PCI-Express InfiniBand Mezzanine card must be added to each server, and the IB driver software right-to-use licenses must be added. A host-based subnet manager must also be added (Linux support only). | |
| Redundant Power Supply | Covered in the enclosure configuration | |
|
|
||
| Compute Node | Specify Number of Nodes | Select number of HP ProLiant
BL2x220c G5 server blades. This is a double-dense blade made of two 2-socket
servers. Total compute nodes cannot exceed 7 nodes. NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/12534.html |
| Memory Options |
HP ProLiant BL2x220c G5 is available with PC2-5300 DDR2 memory. Maximum memory is 32GB per node (64Gb per blade). |
|
| DVD Drive Options | Covered in the enclosure configuration | |
| Disk Options | One NHP SATA drive per server (Two per blade). | |
| PCI - I/O Options | HP ProLiant BL2x220c G5 server blade has two multifunctional Gigabit NICs integrated per server. When InfiniBand interconnect is selected, a PCI-Express InfiniBand Mezzanine card must be added to each server, and the IB driver software right-to-use licenses must be added. | |
| Redundant Power Supply | Covered in the enclosure configuration | |
|
|
||
| HP Cluster Platforms Express with HP ProLiant BL465c G5 Compute Nodes | ||
| Control Node | HP ProLiant BL465c G5 Blade
Server NOTE: Complete information on the HP ProLiant Servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/12534.html |
|
| Choose Processor Option |
All currently shipping processors for each control node are available. Select one or two processors |
|
| Memory Option | HP ProLiant BL465c G5 is available with PC2-5300 or PC2-6400 memory. Maximum memory is 64GB per node. | |
| DVD Drive Option | Covered in the enclosure configuration | |
| Disk Option | One disk minimum for control node, up to two HP SATA or HP SAS Small Form Factor drives can be configured. Optionally, SB40c storage blade can be added for more direct-attached storage. | |
| PCI - I/O Options | HP ProLiant BL465c G5 server blade has two multifunctional Gigabit NICs integrated. When InfiniBand interconnect is selected, a PCI-Express InfiniBand Mezzanine card must be added, and the IB driver software right-to-use license must be added. A host-based subnet manager must also be added (Linux support only). | |
| Redundant Power Supply | Covered in the enclosure configuration | |
|
|
||
| Compute Node | Specify Number of Nodes | Select number of HP ProLiant
BL465c G5 Server. Total compute nodes cannot exceed 7 nodes. NOTE: Complete information on the servers can be found in the following QuickSpecs: http://h18000.www1.hp.com/products/quickspecs/division/12534.html |
| Memory Options |
HP ProLiant BL465c G5 is available with PC2-5300 or PC2-6400 memory. Maximum memory is 64GB per node. |
|
| DVD Drive Options | Covered in the enclosure configuration | |
| Disk Options | One or two HP SATA or HP SAS Small Form Factor Drives. | |
| PCI - I/O Options | HP ProLiant BL465c G5 server blade has two multifunctional Gigabit NICs integrated. When InfiniBand interconnect is selected, a PCI-Express InfiniBand Mezzanine card must be added, and the IB driver software right-to-use license must be added. | |
| Redundant Power Supply | Covered in the enclosure configuration | |
|
|
||
| InfiniBand High Speed Interconnects | |
| InfiniBand |
InfiniBand DDR fabric is based on the HP 4X DDR IB Switch Module for HP BladeSystem c-Class. The HP 4X DDR IB mezzanine HCA has to be configured with each server blades, and IB software and host-based subnet manager (running on control node) must be configured (see above node configuration for more details). |
|
|
|
| Administrative and Console Network | |
| HP GbE2c Ethernet Blade Switch for c-Class BladeSystem |
The administrative GbE2c Gigabit Ethernet switch integrated in the enclosure. Access to the console network is provided by the iLO port on the OA. |
|
|
|
|
|
| Other Infrastructure | |
| Keyboard and Monitor |
A keyboard/monitor (not provided) is needed for initial set up of the enclosure and serer blades. |
| Power |
HP BladeSystem c3000 enclosure supports up to 6 1200W AC Power Supplies. NOTE: Minimum one power supply is required.
To determine the number of power supplies required for the configuration,
please use the HP BladeSystem Power Calculator. |
| Documentation | HP Cluster Platform Workgroup System User Guide |
|
|
|
| Software | |
| OS Support |
Linux
HPC 8 pack ordering information
Windows
|
|
|
|
| Cluster Management | HP Cluster Management Utility |
|
The HP Cluster Management Utility (CMU) is designed to manage a large
number of compute nodes with a Single System View GUI (Graphics User Interface).
HP CMU comes with a full Java GUI that can be tailored for your needs
and for any number of nodes in the cluster. HP CMU is HP SIM (System Integration
Manager) level 1 integration compliant. HP CMU provides a Command Line
Interface (CLI) for day-to-day administration and cloning. Through its
user friendly graphical interface HP CMU provides the cluster administrator
with three main features:
NOTE: Complete information on HP CMU software, including QuickSpecs, can be found at the following URL: www.hp.com/go/cmu |
|
| Platform HPC for Insight Control Environment for Linux (ICE-LX) | |
| Platform HPC enables easy and
rapid deployment and administration of an HPC cluster with choice of popular
open source components, fully supported by HP and Platform Computing. The
combination of Platform HPC and ICE-LX builds on the market-proven ProLiant
system management technology developed by HP for scalable monitoring and
provisioning of its servers, and adds features and options required to deploy
a fully functional HPC cluster, including resource management, MPI and interconnect
network drivers. Platform HPC includes the packages and kitting capability
utilized by Platform in its Open Cluster Stack (OCS) product. NOTE: Ordering information on Platform HPC for ICE-Linux can be found in the QuickSpecs for the product at the following URL: http://h18004.www1.hp.com/products/quickspecs/13193_div/13193_div.html Note that ICE-LX is a pre-requisite for use of Platform HPC for ICE-Linux. |
|
|
|
|
| HP-Message Passing Library (MPI) |
HP's implementation of the Message Passing Library, HP-MPI, is offered as an option with Cluster Platform Express. HP-MPI complies with the MPI-1.2 and MPI-2 standards and is a high performance, robust, high quality, native implementation. HP-MPI enhancements provide optimized point-to-point and collective communication routines. HP-MPI is available for both Linux and Windows. |
|
|
|
| Service and Support |
HP Cluster Platform Workgroup System warranty and service options are based on the offerings of the underlying components. HP customer support provides onsite hardware break/fix support and remote,
remedial software call-center support. Customer support offsite software
services include level 1 and 2 support:
The HP software support team will work in parallel with the appropriate
vendor and development groups to address level 3 and 4 support elevations:
HP has experience servicing systems, networks, storage devices, and software for HPC deployments and environments of all sizes. A wide range of purchasing options and solutions built from standards-based service modules ensure the service coverage and the level of expert assistance desired. Optional services may be purchased at the time of the product purchase as HP Care Pack services, easy to order and easy to use service packages. Optional services may also be purchased at a later point of time as HP Contractual or Per-Event Services to extend and/or expand and/or complement the standard product warranty. Hardware Support: Service capabilities include total lifecycle support, preventive and diagnostic services, access to a global service network, and support for an array of third-party peripherals. Hardware Support Services offer a full range of high-quality remote and onsite hardware support options to meet specific response or repair-time objectives. These support options range from next-day or 4-hour onsite response to 6-hour call-to-repair time commitments. To accommodate specific hours of operations, coverage window options range from standard business hours (9x5), Monday-Friday 8am-5pm local time up to 24x7. Software Support: Standard software support includes 9x5 telephone support and rights to new versions for the specified period of time (one year or three years). 24x7 software support extends the telephone support window to round-the-clock access. Standard software support includes customer access to technical resources during standard hours (see later), problem analysis, escalation management, and resolution. HP also provides unlimited access to an electronic facility that includes a knowledge database with known symptoms and solutions, software product descriptions, specifications, and technical literature. Software support contracts can be obtained to meet the needs of customers, including remedial technical remote support along with migration and upgrade planning and a full suite of proactive deliverables. |
| NOTE: For more
complete information on HP Services offerings, customers and resellers,
please visit us at: http://www.hp.com/hps
NOTE: Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html |
|
|
Configuration Information - Factory Integration
|
IMPORTANT: The HP Cluster Platform, Cluster Platform Express and Cluster Platform Workgroup System are customized by HP and resellers using the Internal Configure-To-Order configurators process to receive a complete factory integrated cluster with options delivered in a single package. The Purchase Order must list each part number individually. The steps below describe the Factory Integration services provided during assembly and delivery of HP Cluster Platform Workgroup System |
|
| For a complete configuration of the HP BladeSystem, please do the following: | |
| Step 1: Determine Hardware Factory Integration services | |
| Factory Integration for HP Cluster
Platform Workgroup System Factory integration of all hardware components conforming to HP Cluster Platform Workgroup System configuration rules. This includes all networking and cluster test of these components at hardware level. Factory integration requires a hardware installation service per solution. An additional charge per node required if software installation is selected (Step 2) |
|
| A Hardware Integration service is required per Cluster Platform Workgroup System solution. | |
| HP Factory Express Server System Custom SVC |
HA839A1
|
|
|
|
| Step 2: Determine Software Factory Installation Services | |
| HPC Cluster Integration Service - | |
| HP CPE Factory SW SVC Clustering Software Load for CMU, ICE-Linux and HP-MPI (including OS) per compute node |
HB488A
|
| HP CPE Factory Linux OS Load SVC for Red Hat or SuSE distributions per compute node |
HB489A
|
|
|
Related Options
| Software | ||
| OS Support | Linux | |
| HPC RHEL 8-pack 2P 1Yr License |
443934-B21
|
|
| HPC RHEL 8-pack 2P 3Yr License |
443935-B21
|
|
| HPC RHEL Single Node 2P 1Yr License |
443938-B21
|
|
| HPC RHEL Single Node 2P 3Yr License |
443939-B21
|
|
| SUSE SLES 1Yr Base Universal 8 pack, Media |
431123-B21
|
|
| SUSE SLES 1Yr Universal Add-on 8 pack |
431127-B21 |
|
| SUSE SLES 3Yr Universal Base 8 pack, Media |
431128-B21
|
|
| SUSE SLES 3Yr Universal Add-on 8 pack |
431129-B21
|
|
| NOTE: HP Care Pack Services required for any part number above | ||
| Microsoft HPC Server 2008 (OS and cluster mgr) | ||
| MS W2008 HPC Svr Npi FIO Eng SW |
504103-B21
|
|
|
|
||
| Cluster Management | HP CMU | |
| HP CMU License and Media |
433257-B21 |
|
| HP CMU Compute Node License |
433258-B21
|
|
| Platform HPC for Insight Control Environment for Linux (ICE-LX) | ||
| Platform HPC Version 1.0 Insight Control
Environment for Linux Software LTU including 1 year Updates and Technical
Support (per server) Requires ICE-LX: |
515776-B21 | |
| HP Insight Control Environment for Linux, 8-Server license, including one year of 24x7 Technical Support and Updates, FIO | 464429-B21 | |
|
|
||
| HP-MPI | HP-MPI for Linux Media Kit |
433039-B21
|
| HP-MPI for Linux 4 Cores LTU |
433028-B21
|
|
| HP-MPI for Linux 8 Cores LTU |
433031-B21
|
|
| HP-MPI for Linux 256 Cores LTU |
433034-B21
|
|
| NOTE: HP-MPI is also included with XC Software, so no separate purchase requirement if XC selected | ||
| HP-MPI for Windows Media Kit |
433051-B21
|
|
| HP-MPI for Windows 4 Cores LTU |
433040-B21
|
|
| HP-MPI for Windows 16 Cores LTU |
433042-B21
|
|
| HP-MPI for Windows 128 Cores LTU |
433045-B21
|
|
|
| ||
| Service and Support Offerings (HP Care Pack Services) |
Red Hat Software Operating Environment Software Telephone, 1 Year 9x5 - 10 incident (Electronic) |
U3402E
|
| Red Hat IA32,Software Technical Support, 1 Year 7x24 - 10 incident (Electronic) |
U3406E
|
|
| SuSE IA, Software Technical Support, 1 Year 7x24 - 10 incident (Electronic) |
U9935E
|
|
| SuSE IA, Software Technical Support, 1 Year 9x5 10 incident (Electronic) |
U9936E
|
|
| HP 1 Year 9x5 10 Incidents MS/Novell Software Technical Support (per Windows cluster) |
U9268E
|
|
| HP 1 Year 24x7 10 Incidents MS/Novell Software Technical Support (per Windows cluster) |
U9269E
|
|
| Windows 1 Year 9x5 Unlimited Software technical Support (per node) |
UF105E
|
|
| Windows 1 Year 24x7 Unlimited Software technical Support (per node) |
UF106E
|
|
| Windows 3 Year 9x5 Unlimited Software technical Support (per node) |
UF107E
|
|
| Windows 3 Year 24x7 Unlimited Software technical Support (per node) |
UF108E
|
|
| HP XC Software 3 year 24x7 1 processor Software Support |
UF092E
|
|
| HP CMU one node 1 year 9x5 STS & Updates - unlimited |
UE871E
|
|
| HP CMU one node 1 year 24x7 STS & Updates - unlimited |
UF086E
|
|
| HP CMU one node 3 year 9x5 STS & Updates - unlimited |
UF087E
|
|
| HP CMU one node 3 year 24x7 STS & Updates - unlimited |
UF088E
|
|
| HP Insight Control Environment for Linux, 3 year, 24x7 Unlimited Software Support for 8 servers, including technical support and Software updates | UK131E | |
| HP-MPI for Linux or Windows 4 Cores LTU 1 Year 9x5 STS & Updates - unlimited |
UF093E
|
|
| HP MPI for Linux or Windows 4 Cores LTU 1 Year 24x7 STS & Updates - unlimited |
UF094E
|
|
| HP-MPI for Linux or Windows 4 Cores LTU 3 Year 9x5 STS & Updates - unlimited |
UF095E
|
|
| HP-MPI for Linux or Windows 4 Cores LTU 3 Year 24x7 STS & Updates - unlimited |
UF096E
|
|
| HP-MPI for Linux 32 Cores LTU 1 Year 9x5 STS & Updates - unlimited |
UF101E
|
|
| HP-MPI for Linux 32 Cores LTU 1 Year 24x7 STS & Updates - unlimited |
UF102E
|
|
| HP-MPI for Linux 32 Cores LTU 3 Year 9x5 STS & Updates - unlimited |
UF103E
|
|
| HP-MPI for Linux 32 Cores LTU 3 Year 24x7 STS & Updates - unlimited |
UF104E
|
|
| HP-MPI for Linux 256 Cores LTU 1 Year 9x5 STS & Updates - unlimited |
UF113E
|
|
| HP-MPI for Linux 256 Cores LTU 1 Year 24x7 STS & Updates - unlimited |
UF114E
|
|
| HP-MPI for Linux 256 Cores LTU 3 Year 9x5 STS & Updates - unlimited |
UF115E
|
|
| HP-MPI for Linux 256 Cores LTU 3 Year 24x7 STS & Updates - unlimited |
UF116E
|
|
| HP-MPI for Windows 16 Cores LTU 1 Year 9x5 STS & Updates - unlimited |
UF097E
|
|
| HP-MPI for Windows 16 Cores LTU 1 Year 24x7 STS & Updates - unlimited |
UF098E
|
|
| HP-MPI for Windows 16 Cores LTU 3 Year 9x5 STS & Updates - unlimited |
UF099E
|
|
| HP-MPI for Windows 16 Cores LTU 3 Year 24x7 STS & Updates - unlimited |
UF100E
|
|
| HP-MPI for Windows 128 Cores LTU 1 Year 9x5 STS & Updates - unlimited |
UF109E
|
|
| HP-MPI for Windows 128 Cores LTU 1 Year 24x7 STS & Updates - unlimited |
UF110E
|
|
| HP-MPI for Windows 128 Cores LTU 3 Year 9x5 STS & Updates - unlimited |
UF111E
|
|
| HP-MPI for Windows 128 Cores LTU 3 Year 24x7 STS & Updates - unlimited |
UF112E
|
|
|
|
||
|
© Copyright 2009 Hewlett-Packard Development Company, L.P. Microsoft and Windows are US registered trademarks of Microsoft Corporation.
Intel, the Intel logo, Xeon and Xeon Inside are trademarks of Intel Corporation
in the U.S. and other countries. AMD, the AMD Arrow logo, AMD Opteron™,
and combinations thereof, are trademarks of Advanced Micro Devices, Inc. |