Overview
|
HP StorageWorks 2000fc G2 Modular Smart Array |
|
The HP StorageWorks 2000fc G2 Modular Smart Array (MSA2000fc) represents
the newest Fibre Channel model of the MSA2000 family (which includes the
MSA2000i G2 iSCSI and the MSA2000sa G2 SAS connected models), a new generation
of HP storage arrays specifically designed for entry-level customers and
features the very latest in functionality and technology at highly affordable
price points. |
| What's New |
|
![]() |
| HP StorageWorks 2024fc G2 Modular Smart Array |
![]() |
| StorageWorks 2012fc G2 Modular Smart Array |
|
|
| Models | ||
| StorageWorks 2000fc G2 Modular Smart Array | Controller-less CHASSIS & MSA2300fc G2 FC Controller | |
| HP StorageWorks 2012 Modular Smart
Array 3.5-in Drive Bay Chassis (LFF) (Will accept one or two controllers or Disk Enclosure I/O modules) |
AJ948A | |
| HP StorageWorks 2024 Modular Smart
Array 2.5-in Drive Bay Chassis (SFF) (Will accept one or two controllers) |
AJ949A | |
| HP StorageWorks 2300fc G2 Modular Smart Array Controller | AJ798A | |
| Disk Enclosures | ||
| HP StorageWorks MSA2000 Single
I/O 3.5-inch 12 LFF Drive Enclosure (w/ two .6m SAS to SAS cables. If connecting to an MSA2300 G2 controller, SAS to mini-SAS cables are required) Used with single controller array head |
AJ749A | |
| HP StorageWorks MSA2000 Dual I/O
3.5-inch inch 12 LFF Drive Enclosure (w/ two .6m SAS to SAS cables. If connecting to an MSA2300 G2 controller, SAS to mini-SAS cables are required) Used with dual controller array head |
AJ750A
|
|
| HP StorageWorks MSA2000 Drive
Enclosure I/O Module (no cable included) |
AJ751A | |
| HP StorageWorks MSA70 2.5-inch
25 SFF Drive Enclosure 2.5 in Drive Enclosure (single I/O, single domain) (w/one .5m miniSAS to miniSAS cable) |
418800-B21 | |
| HP StorageWorks Dual Domain I/O
Module for MSA70 enclosure (upgrades MSA70 to dual domain) (w/ one .5m miniSAS to miniSAS cable) |
AG779A | |
| MSA2300fc SAN Starter Kits | ||
| HP StorageWorks 2312fc G2 Single
Controller Modular Smart Array SAN Starter Kit (LFF) (includes single controller, 12-drive bay LFF array head, 8-port 8Gb switch, two 8Gb HBAs, SFPs and cables) |
AJ954A | |
| HP StorageWorks 2324fc G2 Single
Controller Modular Smart Array SAN Starter Kit (SFF) (includes single controller, 24-drive bay SFF array head, 8-port 8Gb switch, two 8Gb HBAs, SFPs and cables) |
AJ955A | |
| HP StorageWorks 2300fc G2 Modular
Smart Array SAN Starter HA Upgrade Kit (includes additional single controller, 8-port 8Gb switch, two more 8Gb HBAs, SFPs and cables) For upgrading AJ954A or AJ955A to dual controller, high availability configurations |
AJ956A | |
| Configured Units | ||
| HP StorageWorks 2312fc G2 Dual
Controller Modular Smart Array (LFF) (Pre-configured with two array controllers) |
AJ795A | |
| HP StorageWorks 2324fc G2 Dual
Controller Modular Smart Array (SFF) (Pre-configured with two array controllers) |
AJ797A | |
| Controller-less Chassis: DC-powered units | ||
| HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay DC-power Chassis (LFF) (can add one or two MSA2300fc G2 controllers or MSA2000 JBOD I/O modules) | AJ950A | |
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay DC-power Chassis (SFF) (can add one or two MSA2300fc G2 controllers. No MSA2000 JBOD I/O module support) | AJ951A | |
| Controller-less Carrier Grade Chassis | ||
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Carrier-Grade Chassis (SFF) | AM337A | |
| Related Option | ||
| HP StorageWorks 2000fc Modular
Smart Array Controller (limited use) (for use only with an AJ948A LFF chassis for those needing to configure an older MSA2012fc. Only supports older features, functionalities. No SFF or MSA70 JBOD support, max 48 LFF drives, max 64 snaps; no HP-UX, OpenVMS, or Integrity server support) |
AJ744A | |
|
|
Features and Benefits
| Key Hardware Features |
|
|
|
| Customer Benefits |
|
|
|
| HP MSA2000fc G2 Models At a Glance: |
|
|
|
| HP MSA2024fc G2 Carrier-Grade Components |
HP StorageWorks 2024 Modular Smart
Array 2.5-in Drive Bay Carrier-Grade Chassis The MSA2000fc G2 is a 4 Gb Fibre Channel connected 2U storage area network (SAN) or direct connect solution designed for network equipment providers (NEPs) and communication service providers. Suited for those who need a robust telecom infrastructure--- they need storage devices to catch videos, photos, text, new services---need a place to have the data stored and cached. The MSA is a high-quality entry-level FC array, ideal for customers with limited budgets. The HP MSA2024 Carrier-Grade Chassis (AM337A) is a controller-less chassis capable of supporting one or two MSA2300fc G2 Fibre Channel controllers (AJ798A) and has twenty-four Small Form Factor (SFF) drive bays. It comes equipped with two DC-power power supplies. When used in conjunction with the Seismic cabinet (AH343A) and specific ProLiant SFF SAS drives, the solution is NEBS certified. NEBS level-3 certification provides the assurance that the equipment is safe to operate and sturdy enough to withstand certain physical (for example, acoustics) and environmental (for example, fire, earthquakes) conditions. Maximum capacity is achieved with twenty-four 146 GB drives yielding 3.5 TB in 2U of rack space. No JBODs or disk enclosures are part of the NEBS certification This Storage array augments HP's Carrier-Grade portfolio of solutions and will attach to both the Bladeserver and ProLiant carrier-grade rack mount servers. |
AM337A |
| Certifications | NEBS Level 3 (GR-63 and GR-1089), Seismic Zone 4 | |
| Controller | HP StorageWorks 2300fc G2 Modular Smart Array Controller (1 or 2) | AJ798A |
| Qualified Drives | HP 72GB 3G SAS 15K SFF DP ENT HDD | 418371-B21 |
| HP 146GB 3G SAS 10K SFF DP ENT HDD | 418367-B21 | |
| HP 300GB 3G SAS 10K SFF DP ENT HDD | 492620-B21 | |
| Racking | Order stand-alone or to be racked in HP seismic rack | |
| Mezz Card (HBA) | QLogic for BL460c | |
| QLogic for BL860c | ||
| Supported Interconnect | c7000-cg - Brocade SAN 4/12 and 4/24 | |
| For more information
on HP Carrier Grade Platforms go to http://www.hp.com/products1/servers/carrier_grade/index.html?jumpid=reg_ R1002_USEN |
|
|
Family Information
|
MSA2000fc G2
|
MSA2000i
|
MSA2000sa |
Comparison w/ EVA4400
|
|
| Capacity Minimum / with maximum additional drive enclosures |
LFF: 5.4 TB SAS |
LFF: 5.4 TB SAS |
LFF: 5.4 TB SAS or 12 TB SATA w/ 4 drive enclosures 21.6 TB SAS or 48 TB SATA SFF: 7.2 TB SAS or 6 TB SATA w/ 3 MSA70 JBODs: 29.7 TB SAS or 24.7 TB SATA |
LFF: 5.4 TB FC |
| Controller Cache |
1 GB per controller
|
1 GB per controller
|
1 GB per controller |
2 GB per controller
|
| Total LUNs | 512 | 511 | 512 | 1024 |
| Host connect MSA2000 have 1 or 2 controllers, EVA has 2 controllers standard |
Two 4 Gb |
Two 1 GbE |
Four 3 Gb SAS ports per controller |
Two 4 Gb |
| Maximum Drives w/ expansion |
60 LFF/99 SFF
|
60 LFF/99 SFF
|
60 LFF/99 SFF |
96
|
| Maximum host supported |
64
|
32
|
64** |
512
|
| Snapshot, clone |
Snapshot (max 255) clone
|
Snapshot (max 255)
clone |
Snapshot (max 255) clone |
Snapshot, clone, |
| Use for Storage |
Primary Storage
with SAS. Secondary with SATA |
Primary Storage
with SAS. Secondary with SATA |
Primary Storage with SAS. Secondary with SATA |
Primary Storage
with FC Secondary with FATA |
| NOTE: maximum
available storage capacity depends on the RAID level being implemented,
and is based on maximum number of LUNs and LUN size. ** Supports up to 8 hosts with SAS direct connect and 64 hosts (BladeSystem servers) using 3Gb SAS BL switch |
|
|
|
Product Technology |
4 Gb Fibre Channel technology | Two host ports per controller, shipped with SFPs. the MSA2000fc G2 controller can run in either point-to-point or FCAL (loop). The default is FCAL which is used in Direct Connect, particularly with two controllers. The PtP (fabric) mode is used with almost all switches. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Modular Chassis | 2U rack height. 12 Large Form Factor or 24 Small Form Factor drive bays, accommodating SAS and SATA. Comes with space for one or two controllers, or MSA2000 3.5-inch disk Enclosure I/O modules (LFF chassis only) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Drives available | The new MSA2000fc
G2 controller supports either the MSA2 3.5-inch Large Form Factor (LFF)
drives, or the HP ProLiant 2.5-inch Small Form Factor (SFF) drive Serial Attached SCSI (SAS) enterprise-class drives designed for high volume, 24x7 usage. Serial-ATA (SATA) are usually reserved for archival of data as they are both relatively inexpensive and are available in very large capacities. The MSA2000 family of arrays can accommodate both SAS and SATA drives within the same enclosure making it ideal to have both business-critical, high activity files on SAS drives while using Snapshot or clone capability to keep back-up or archival data on the less expensive drives. For investment protection, the MSA2300fc G2 controller will support single port SAS & SATA drives in a single-domain MSA70. This support allows current owners of MSA70s to migrate their single port drives (in their MSA70 only, not into the array head) to be attached to an MSA2300fc. They can only cascade to another single I/O MSA70. This is not a data-in-place transition. SAS drive performance can be approximately 30% greater than SATA performance on sequential host I/O. SAS performance excels in sequential lower latency response time and random I/O per second transaction performance due to higher rpm disk speeds yielding lower seek times. SAS drive random performance is generally twice that of SATA drives. NOTE: MSA2 3.5-inch Large Form Factor (LFF) drives are for use only in the MSA2000 family. The 2.5-inch Small Form Factor (SFF) drives are supported only with the MSA2300fc G2 controller and are common with and are the same part numbers as the ProLiant optional 2.5-inch drives. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Optional Disk enclosures | Just as the user has a choice of chassis for the array head (LFF and SFF drive bays), so also do they have a choice of expansion disk enclosures accommodating either drive size. (NOTE: these are not supported as part of a NEBS-certified with the MSA Carrier Grade Chassis.) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
MSA2000 3.5-inch drive enclosure. This 2U unit has twelve LFF (3.5-inch) drive bays and accepts for MSA2 dual-ported SAS and SATA drives. One model (AJ749A) has a single I/O module that matches with a single controller array head, giving a single path to the drives. The second model (AJ750A) comes standard with two I/O modules installed, required when paired with a dual controller array head, giving two paths to the drives for higher availability.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
MSA70 2.5-inch drive enclosure. This 2U storage enclosure (418800-B21) is designed to support twenty five ProLiant 2.5-inch Universal form factor (SFF) SAS or SATA hard drives. It ships standard with a single I/O module installed.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Scalability |
The MSA2300fc G2 controller is designed to allow an installation to begin with smaller capacity and be able to grow gradually as needed. The flexibility of SAS or SATA drive technology, form factors, sizes, speeds, and costs per GB allows a system to easily fit in almost any budget.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| LUNs | The MSA2000 family of arrays supports 512 LUNs (total volumes in a dual controller system) and LUN sizes up to 16 TB. The array supports expansion and deletion of any LUN. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| RAID 0, 1, 3, 5, 6, 10, 50 | In addition to the usual RAID levels, the MSA2000 family features several important additional levels. RAID 6 is the highest level of RAID protection. It allocates two sets of parity data across drives and allows simultaneous write operations. It can withstand two simultaneous drive failures without downtime or data loss. RAID 10 is mirroring and striping without parity. It is the most popular of the multiple RAID levels, allowing large arrays with high performance in most cases and superior fault tolerance. RAID 50 combines the block striping and parity of RAID 5 with the straight block striping of RAID 0, yielding higher performance than RAID 5 through the addition of RAID 0, particularly during writes. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Performance | Performance numbers
are a guideline as established by tests using RAW I/O in an Operating System
Agnostic test lab environment. A total of 96 72GB 15K SAS drives were used
in a dual controller configuration of eight 12 Disk vdisks, eight 806 GB
volumes, and two volumes per host. Four hosts directly attached to the MSA2000fc
G2 were used in this test configuration (results cannot be expected with
a single host). Results were achieved in Sequential Writes with 256K blocks;
all random tests were based on 8K block sizes. NOTE: Number and type of applications, drive type and number of drives, operating system used, and the number of hosts will affect overall performance. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DC-power chassis | HP is making the two
models of controller-less chassis available with direct current (DC) power
supplies. They each have the two empty bays where users can insert one or
two MSA2300fc G2 controller(s). In addition, the MSA2012 LFF drive bay can
have MSA2000 3.5-inch I/O modules inserted to create a LFF DC-power JBOD.
The 500 watt power supply is designed to operate over the input range of -40VDC to -75VDC. This is specifically intended to conform to Telco requirements. Certification is in process but no claims are made at this time. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay DC-power Chassis (LFF) | AJ950A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay DC-power Chassis (SFF) | AJ951A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Configuration and Management Tools |
HP StorageWorks MSA Storage Management Utility (SMU). Management access, out-of-band: WEB GUI, CLI. Interface Types: Mini DB9 RS232, 10/100 Ethernet Protocols Supported SNMP, SSL, SSH, SMTP, HTTP, Telnet |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Hot Plug Expansion and Replacement Support | All MSA2000 models support hot plug expansion and replacement of redundant controllers, enclosures, fans, power supplies, and I/O modules for simple, fast installation and maintenance. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Snapshot and Clone | Optional controller based functionality. Offers higher levels of data protection, enabling an almost instant recovery from data failure or corruption. Offers alternative development testing of 'offline' production data and the ability to backup snapped/cloned data. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Overview | The MSA2000fc G2 comes integrated with web
browser based software for storage and RAID management, setup, configuration
and troubleshooting. This reduces the cost of ownership by reducing the
training and technical expertise necessary to install and maintain your
HP storage solution. The SPOCK database provides interoperability information for thousands of components and millions of component combinations. It is available to all users on the HP.com website. http://www.hp.com/storage/spock |
| Server Compatibility |
Supports most HP ProLiant and Integrity servers including
|
| Industry Standard X86 servers support |
|
| OS Support (x86) |
|
| OS Support (Integrity, HP9000) |
|
| Web Browser support |
|
|
|
Optional Software
|
MSA2300 Snapshot and Volume Copy Software |
Product Features | ||
|
Data Protection
|
|||
|
Data Testing
|
|||
| HP StorageWorks 2000 Modular Smart Array Snapshot 255 Software LTU1 |
T5539A
|
||
| HP StorageWorks 2000 Modular Smart Array Snapshot 64 Software LTU |
T5512A
|
||
| HP StorageWorks 2000 Modular Smart Array Snapshot 8 Software LTU |
T5513A
|
||
| HP StorageWorks 2000 Modular Smart Array Snapshot 8/255 Upgrade Software LTU1 |
T5540A
|
||
| HP StorageWorks 2000 Modular Smart Array Snapshot 64/255 Upgrade Software LTU1 | T5541A | ||
| HP StorageWorks 2000 Modular Smart Array Snapshot 8 to 64 Upgrade Software LTU | T5515A | ||
| HP StorageWorks 2000 Modular Smart Array Volume Copy Software LTU | T5514A | ||
| 1 The snapshot software is supported on the MSA2324 and MSA2312 (G2) models only | |||
| Path failover (MPIO) |
MPIO Basic Failover for Windows provides a single multi-path solution for HP StorageWorks MSA2000fc Modular Smart Array on HP ProLiant servers by providing basic path failover. Supports Windows 2003, Windows 2003 R2, and Windows 2003 X64 operating systems.
|
||
| HP StorageWorks Storage Mirroring |
HP StorageWorks Storage Mirroring Software provides host-based, continuous
replication for customers seeking a low-cost alternative to fabric or
array-based replication. Patented replication and failover technology
continuously captures byte-level data changes as they happen and replicates
those changes to one or more target servers at any location without geographic
limitations. By replicating only the bytes that change, Storage Mirroring
Software uses the absolute minimum bandwidth on your existing LAN or WAN
to replicate your data. Storage Mirroring also provides server failover
where a production server can automatically be 'replaced' by the storage
mirroring server in the event of failure. Couple Storage Mirroring with
MSA2000 Snapshots and/or Volume Copy to achieve an Enterprise class data
protection strategy creating different data recovery points using continuous
data protection with Storage Mirroring and point-in-time data protection
with Snapshots and/or Volume Copy.
For more information visit http://h18006.www1.hp.com/products/storage/software/sm/index.html |
||
| HP StorageWorks Storage Mirroring Software Windows Server Edition 1 LTU |
T5438A
|
||
| HP StorageWorks Storage Mirroring Software Windows Enterprise Server Edition 1 LTU |
T5440A
|
||
| HP StorageWorks Storage Mirroring Software Windows NAS Edition 1 LTU |
T5442A
|
||
| HP StorageWorks Storage Mirroring Software for AiO Edition 1 LTU |
T5446A
|
||
| HP StorageWorks Storage Mirroring Software for 5 Virtual Machines 1 LTU |
T5444A
|
||
| HP StorageWorks Storage Mirroring SW Linux 1 LTU | T5448A | ||
| HP StorageWorks Storage Mirroring Virtual Infrastructure 1 LTU | T5450A | ||
| NOTE: For more
information visit http://h18006.www1.hp.com/products/storage/software/sm/index.html |
|||
|
HP StorageWorks X3000 Network Storage Gateways: |
Stretch your MSA2000 array investment by adding file & print services,
iSCSI connectivity, and management hosting with an X3000 Series Network
Storage Gateway platform. X Series Network Storage Gateways are optimized
file and print server solutions that are built on industry-standard HP
ProLiant servers and come with Microsoft Windows Storage Server 2008 operating
system pre-installed. Since they're Windows-based, network integration
is easy, your tools and data protection applications run right on the
box, and management has a familiar look and feel. Like many Network Attached
Storage (NAS) devices, they support heterogeneous file serving environments
and are pre-configured to install in minutes. |
||
|
HP StorageWorks X3400 Network Storage Gateway |
AP796A
|
||
|
HP StorageWorks X3800 Network Storage Gateway |
AP797A
|
||
| HP ProLiant DL380 G5 SAN Gateway
Storage Server NOTE: Microsoft Windows Unified Data Storage Server 2003 Enterprise x64 Edition O/S with file/print, iSCSI, and cluster services on a 2U rack form factor platform. For more information, go to: http://h18006.www1.hp.com/products/quickspecs/12559_div/12559_div.html |
AG771B
|
||
| HP ProLiant SB460c SAN Gateway
Storage Server NOTE: Microsoft Windows Unified Data Storage Server 2003 Enterprise x64 Edition O/S with file/print, iSCSI, and cluster services on a blade form factor platform. For more information, go to: http://h18006.www1.hp.com/products/quickspecs/13114_div/13114_div.html |
AN583A | ||
| Fibre Channel HBA options for DL380 G5 Storage Servers | |||
| HP StorageWorks FC2142SR 4Gb PCIe HBA |
A8002A
|
||
| HP StorageWorks FC2242SR Dual Channel 4 Gb PCIe HBA | A8003A | ||
| HP StorageWorks FC1142SR 4Gb PCIe HBA | AE311A | ||
| HP StorageWorks FC1242SR Dual Channel 4 Gb PCIe HBA | AE312A | ||
| HP StorageWorks 81Q PCI-e FC HBA | AK344A | ||
| HP 82Q 8Gb Dual Port PCI-e FC HBA | AJ764A | ||
| HP StorageWorks 81E 8Gb SP PCI-e FC HBA | AJ762A | ||
| HP 82E 8Gb Dual-port PCI-e FC HBA | AJ763A | ||
| Fibre Channel HBA options for the SB460c SAN Gateway Storage Server | |||
| Emulex LPe1105 FC Dual Channel 4Gb, PCI-E-to-Fibre Channel Host Bus Adapter |
403621-B21
|
||
| QLogic QMH2462 4Gb FC HBA for HP c-Class BladeSystem | 403619-B21 | ||
|
|
Service and Support, HP Care Pack, and Warranty Information
| Warranty |
Enclosures, Hard drives, and Options for the MSA2000fc
carry their own warranty. Refer to HP's Limited Warranty Statement for
more information.
The MSA2000fc has been designed with customer self repairable parts to minimize repair time and provide greater flexibility in performing defective parts replacement. Please refer to HP's limited warranty Statement and parts replacement instructions for further details. http://h18006.www1.hp.com/products/storageworks/warranty.html Products included in various Kits carry their own individual warranties. NOTE: The warranty of the hard drive options purchased with the MSA2000fc product is different for SAS hard drives versus SATA hard drives. SAS hard drive options have a three year warranty and SATA hard drives options have a one year warranty. |
|
|
|
|
HP Care Pack Services. Scalable, Flexible, Dependable.
Like your storage.
For many products, post-warranty HP Care Pack Services are available
when your original warranty has expired. Choose the support levels that
meet your business requirements, from basic to mission-critical. http://www.hp.com/hps/storage |
|
|
| Related Services |
Services that will enhance the user experience
in many product deployments
|
|
|
HP SAN Solution Service
|
Get your SAN implementation right - right from the start.
Storage has become essential to the growth and agility of your business. That's why choosing an HP SAN as your data management solution is a smart business decision. But your SAN can deliver the results you need only if it is implemented correctly and integrated with your business. SAN installation, startup, and integration call for specialized expertise in planning and design, hardware configuration, network software installation, and operability verification. Your SAN needs to be configured for high performance and availability. And it needs to be integrated with your applications, management environment, and business processes. |
|
| HP Data Migration Service | Minimize the risks
involved in transferring data to your HP StorageWorks SAN. You need to move your critical enterprise data to your new HP StorageWorks SAN platform. And you need to accomplish that without losing data. And without interrupting your ongoing business operations. HP Data Migration Service helps you lessen the risk of data loss, minimize threats to data integrity, and avoid productivity-sapping performance slowdowns during data transport. A highly experienced HP Services storage specialist works with you to rapidly and securely migrate mission-critical business information across your data center or around the globe - regardless of the complexity of your environment. |
|
| HP Backup & Recovery Solution Service - ISV | This service consists
of installation of the ISV backup software for the supported SAN environment
per HP's and the ISV's quality standards by a trained service specialist.
HP Backup and Recovery Solution Service for ISV Backup Software provides
for the implementation of the supported ISV backup software in a SAN environment.
The two levels of service described here are based on the size and complexity
of the backup environment. This service is available for VERITAS NetBackup, VERITAS Backup Exec, CommVault Galaxy, and Legato NetWorker. Implementation of CommVault Galaxy is only available as a Level 3 service. |
|
|
|
||
| eSupport |
HP eSupport is a portfolio of technology-based services
that assist you with managing your business environment - from the desktop
to the data center.
Support Portal The HP support portal provides one-stop access to the information, tools and services you need to manage the daily operations of your IT environment. Features include:
Access to certain features of the support portal requires
an HP service agreement. To access the support portal, visit: http://www.hp.com/support
|
|
Remote Support Technology (RST)-HP Remote Support Pack
Taking a more proactive approach to IT support, the HP Remote Support pack plug-in module easily integrates with HP Systems Insight Manager to provide a powerful, unified "single pane of glass" solution for onsite and remote management. HP Remote Support Pack enhances HP Systems Insight Manager with intelligent event diagnosis plus the automatic submission of hardware event notifications securely to HP support, including acknowledgment and status returns. It adds remote configuration collections to allow the delivery of assessment and proactive services for your SAN storage and HP-UX environments. |
|
|
|
|
| Customer Technical Training | Consider education as an integral part of your strategy to get the best return on investment for your HP storage solution. HP offers a variety of training courses on storage software, networking, archiving and disk storage systems. Our classes are available in many delivery modalities from traditional instructor-led courses at one of our 80 training centers worldwide to on-site training customized to your needs or online. www.hp.com/learn/storage |
|
|
|
| HP Services Awards |
HP Services continues to be recognized for service and
support excellence by customers, partners, industry organizations and
publications around the world. Recent honors and award reflect our services
team's dedications, technical expertise, professionalism and uncompromising
commitment to customer satisfaction. For a list of all our awards, please
visit http://h20129.ww2.hp.com/services/cache/77318-0-0-225-121.html.
|
|
|
|
| Additional Services Information | For more information
about HP Care Pack Services for Storage, please visit: http://www.hp.com/hps/storage If you have specific questions, contact your local HP representative. Contact information for a representative in your area can be found at "Contact HP" http://www.hp.com |
|
|
|
| Warranty Upgrade Options |
|
|
|
|
| Software Product Services | Product support
provides the customer access to HP's experienced technical support resources, as well as access to HP's Information Services database for support on a variety of multi-vendor/multiplatform software products. Product support includes escalation and problem coordination with the appropriate engineering group. HP Services offer a variety of options to allow you to tailor your product service to meet the needs of your organization. Basic warranty on products can be uplifted from day one to ensure you receive the service you need when you need it. |
|
|
Configuration Information
![]() |
|||||
|
Dual Controller MSA2000fc G2
|
|||||
| 1. | Power Switch | 3. | CLI Port | 5. | Service Ports |
| 2. | Fibre Channel Ports | 4. | Ethernet Ports | 6. | Expansion Ports |
|
|
|||||
![]() |
|||||
| MSA70 Dual I/O 2.5-inch 25 Drive Enclosure | |||||
| Rear Panel components | |||||
| 1. | Power Supply 1 | 4. | SAS in connector | 7. | I/O module bay |
| 2. | System fan 1 | 5. | SAS out connector | 8. | System fan 2 |
| 3. | Dual 7 segment display board (for future use) | 6. | I/O module bay | 9. | Power supply 2 |
|
|
|||||
![]() |
|||||
| MSA2000 Dual I/O 3.5-inch 12 Drive Enclosure | |||||
| Rear Panel components | |||||
| 1. | Service Port | 4. | DC Voltage / Fan Fault | 6. | SAS In Port |
| 2. | Unit Locator | 5. | AC Power Good | 7. | SAS Out Port |
| 3. | Power Switch | ||||
|
|
|||||
| Configure to Order Program Information | ||
|
HP introduces the new Configure to Order program for the
MSA2000 family The MSA2000 models and options may or may not be factory
installed in a rack with add-on controllers, switches, hubs, MSA2000 disk
enclosures and hard drives. The MSA2000 arrays may be integrated with
ProLiant servers or as standalone storage.
Orders to be shipped through the CTO process must have a minimum of two drives ordered per controller. SAN Starter Kits are not eligible for CTO. The Small Form Factor 300GB drive is not available for rack-level CTO at this time. |
||
| Description | Product # | |
| HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay Chassis (LFF) | AJ948A#0D1 | |
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Chassis (SFF) | AJ949A#0D1 | |
| HP StorageWorks 2300fc G2 Modular Smart Array Controller | AJ798A#0D1 | |
| HP StorageWorks 2312fc G2 Dual Controller Modular Smart Array (LFF) | AJ795A#0D1 | |
| HP StorageWorks 2324fc G2 Dual Controller Modular Smart Array (SFF) | AJ797A#0D1 | |
| HP 2000fc Modular Smart Array Controller (ONLY for use by those wishing to build an older model MSA2012fc)) | AJ744A#0D1 | |
| HP MSA2000 3.5in Single I/O 12 Drive Encl | AJ749A#0D1 | |
| HP MSA2000 3.5in Dual I/O 12 Drive Encl | AJ750A#0D1 | |
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay Carrier-Grade Chassis | AM337A#0D1 | |
| HP StorageWorks 2012 Modular Smart Array 3.5-in Drive Bay DC-power Chassis (LFF) | AJ950#A0D1 | |
| HP StorageWorks 2024 Modular Smart Array 2.5-in Drive Bay DC-power Chassis (SFF) | AJ951A#0D1 | |
| HP MSA2000 Drive Enclosure I/O Module (for CTO, only available for use in a AJ950A DC-powered chassis) | AJ751A#0D1 | |
| HP MSA2 146GB 3G 15K 3.5-inch SAS HDD | AJ735A#0D1 | |
| HP MSA2 300GB 3G 15K 3.5 inch SAS HDD | AJ736A#0D1 | |
| HP MSA2 450GB 3G 15K 3.5 inch SAS HDD | AJ737A#0D1 | |
| HP MSA2 500GB 7.2K 3.5 inch SATA HDD | AJ738A#0D1 | |
| HP MSA2 750GB 7.2K 3.5 inch SATA HDD | AJ739A#0D1 | |
| HP MSA2 1TB 7.2K 3.5 inch SATA HDD | AJ740A#0D1 | |
|
|
||
| MSA70 | Single I/O, single domain 25 Small Form Factor (SFF) drive bays |
418800-B21 |
| MSA70 I/O Module | HP StorageWorks Dual Domain I/O Module | AG779A |
| Makes
the standard MSA70 (above) into a dual I/O, dual domain JBOD NOTE: The I/O Module is a field upgradeable Option Kit the addition of which in the MSA70 will allow dual domain capability providing higher level of redundancy and reliability |
||
| SAS Drives (SFF 2.5-inch) | HP 72GB 3G SAS10K SFF DP ENT HDD | 384842-B21 |
| HP 146GB 3G SAS10K SFF DP ENT HDD | 418367-B21 | |
| HP 300GB 3G SAS 10K SFF DP ENT HDD | 492620-B21 | |
| HP 36GB 3G SAS15K SFF DP ENT HDD | 418369-B21 | |
| HP 72GB 3G SAS15K SFF DP ENT HDD | 418371-B21 | |
| HP 146GB 3G SAS15K SFF DP ENT HDD | 504062-B21 | |
| NOTE: Only Dual Port (DP) drives will work as dual-port in a Dual Domain environment. Dual Domain environment requires the HP StorageWorks Dual Domain I/O Module Option (# AG779A). | ||
| SATA Drives (SFF 2.5-inch) | HP 120 GB 1.5G SATA 5.4K 2.5-inch SFF HDD | 458924-B21 |
| HP 250 GB 3G 5.4K 2.5-inch SFF SATA ETY HDD | 460355-B21 | |
| NOTE: SATA drives
for the MSA70 are not dual port (DP) drives. NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibility information (http://www.hp.com/products/harddiskdrives). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data. |
||
|
|
||
| Step 1 - MSA2000fc G2 - Base Configuration | ||
| Select one: | ||
| Model Name | Model Description: |
Part Number
|
| HP StorageWorks 2012 Modular Smart Array 3.5-inch Drive Bay Chassis | Controller-less chassis with twelve Large Form Factor (LFF) MSA2 drive bays. Space for two controllers. |
AJ948A
|
| HP StorageWorks 2024 Modular Smart Array 2.5-inch Drive Bay Chassis | Controller-less chassis with twenty-four Small Form Factor (SFF) ProLiant drives bays. Space for two controllers. |
AJ949A
|
| There are two array-head chassis - one with twelve 3.5-inch large form factor bays, the other with twenty-four 2.5-inch small form factor drive bays. For additional twelve additional drive bays purchase an MSA2000 3.5-inch Disk Enclosure. You may attach a total of four MSA2000 Drive Enclosures for a total of sixty LFF drive bays. For 25 additional SFF drive bays purchase an MSA70 JBOD with the 2nd I/O module. You may attach a total of three MSA70 JBODs for a total of ninety-nine SFF drive bays. Single controller arrays support Single I/O Disk Enclosures; dual controller arrays support Dual I/O Disk Enclosures. | ||
|
|
||
| Step 2 - Options | ||
| Select each option with quantities specified. | ||
|
Step 2a - Options
|
||
| Description with Parts Shipped: |
Quantity
|
Part Number
|
|
HP StorageWorks 2300fc G2 Modular Smart Array Controller
(for either the LFF MSA2012, SFF MSA2024, or the two DC-powered chassis) |
1 or 2 | AJ798A |
|
Step 2b - SAS and SATA Drive Options
NOTE: SATA drives are designed for archival or reference data. They should not be used in a heavy or intense I/O environment. Those situations require the use of enterprise-class SAS drives. MSA2 3.5-inch drives are for use only with MSA2000 products. |
||
| MSA2 Large Form Factor (LFF) SAS drives for MSA2312fc and MSA2000 3.5-inch Disk Enclosure | ||
| HP StorageWorks MSA2 146GB 3G 15K 3.5 inch Dual-port SAS LFF HDD |
AJ735A
|
|
| HP StorageWorks MSA2 300GB 3G 15K 3.5 inch Dual-port SAS LFF HDD |
AJ736A
|
|
| HP StorageWorks MSA2 450GB 3G 15K 3.5 inch Dual-port SAS LFF HDD | AJ737A | |
| MSA2 Large Form Factor (LFF) SATA drives for MSA2312fc and MSA2000 3.5-inch Disk Enclosure | ||
| HP StorageWorks MSA2 500GB 7.2K 3.5-inch SATA LFF HDD |
AJ738A
|
|
| HP StorageWorks MSA2 750GB 7.2K 3.5-inch SATA LFF HDD |
AJ739A
|
|
| HP StorageWorks MSA2 1TB 7.2K 3.5-inch SATA LFF HDD | AJ740A | |
| ProLiant Small Form Factor (SFF) SAS drives for MSA2324fc G2 and MSA70 JBOD | ||
| 6G SFF Serial Attached SCSI (SAS) Hard Drives | ||
| HP 72GB 6G SAS 15K 2.5 inch SFF DP ENT HDD | 512545-B21 | |
| HP 146GB 6G SAS 10K 2.5 inch SFF DP ENT HDD | 507125-B21 | |
| HP 146GB 6G SAS 15K 2.5 inch SFF DP ENT HDD | 512547-B21 | |
| HP 300GB 6G SAS 10K 2.5 inch SFF DP ENT HDD | 507127-B21 | |
| NOTE: 6G SAS drives will only function as 3G drives in a MSA70 or MSA2024 G2 array. | ||
| NOTE: In a single domain environment Dual Port (DP) drives will function as Single Port (SP) drives only. | ||
| 3G SFF Serial Attached SCSI (SAS) Hard Drives | ||
| HP 72GB 3G SAS10K SFF DP ENT HDD | 384842-B21 | |
| HP 146GB 3G SAS 10K SFF DP ENT HDD | 418367-B21 | |
| HP 300GB 3G SAS10K SFF DP ENT HDD | 492620-B21 | |
| HP 36GB 3G SAS 15KSFF DP ENT HDD | 418369-B21 | |
| HP 72GB 3G SAS 15K SFF DP ENT HDD | 418371-B21 | |
| HP 146GB 3G SAS 15K SFF DP ENT HDD | 418367-B21 | |
| ProLiant Small Form Factor (SFF) SATA drives for MSA2324fc G2 and MSA70 JBOD | ||
| HP 120 GB 1.5G 5.4K 2.5-inch SATA SFF HDD | 458924-B21 | |
| HP 250 GB 3G 5.4K 2.5-inch SFF SATA ETY HDD | 460355-B21 | |
|
Step 2c - Drive Enclosure Options
|
||
| Should you want a drive enclosure, the model you choose depends on which array model it attaches to. If it is a single controller array, then choose the JBOD designated as "Single I/O". If it is attaching to a dual controller array then choose the "Dual I/O" JBOD | ||
| HP StorageWorks MSA2000 Single
I/O 3.5-inch 12 Drive Enclosure (use with single controller array heads. Ships with two .6m SAS to SAS cables suitable for connecting to the original MSA2000 controller. When connecting to the MSA2000fc G3 controller, the user must purchase the SAS to miniSAS cable such as the .5m 419569-B2) |
AJ749A
|
|
| HP StorageWorks MSA2000 Drive
Enclosure I/O Module (Use to upgrade the Single I/O model to dual I/O. No cable included) |
AJ751A
|
|
| HP StorageWorks MSA2000 Dual I/O
3.5-inch 12 Drive Enclosure (use with dual controller array heads. Ships with two .6m SAS to SAS cables suitable for connecting to the original MSA2000 controller. When connecting to the MSA2000fc G3 controller, the user must purchase the SAS to miniSAS cable such as the .5m 419569-B2) |
AJ750A
|
|
| HP StorageWorks 70 Modular Smart
Array (MSA70) SFF 2.5-inch drive Single I/O JBOD Single I/O, single domain. 25 Small Form Factor (SFF) drive bays (use only with MSA2324fc array head. Includes one miniSAS to miniSAS cable) |
418800-B21
|
|
| HP StorageWorks Dual Domain I/O
Module for MSA70 Makes the standard MSA70 (above) into a dual I/O, dual domain JBOD (Includes one miniSAS to miniSAS cable) |
AG779A
|
|
| MSA70 NOTE:
Only Dual Port (DP) drives will work in the Dual Domain environment. Dual
Domain environment requires the HP StorageWorks Dual Domain I/O Module Option
(# AG779A). For more information on the MSA70, go to the MSA70 Home Page: http://h18006.www1.hp.com/storage/disk_storage/msa_diskarrays/drive_enclosures/msa70/index.html |
||
| Step 2c - SAS Cable Options | ||
| miniSAS to miniSAS Cables:
Connecting MSA2300fc controller to MSA70 JBOD if a longer cable is desired. |
||
| HP Ext miniSAS to miniSAS 1m Cable | 407337-B21 | |
| HP Ext miniSAS to miniSAS 2m Cable | 407339-B21 | |
| SAS to miniSAS Cables: Connecting MSA2300fc controller to MSA2000 3.5-inch Disk Enclosure |
||
| HP SAS to miniSAS .5m Cable | 419569-B21 | |
| HP SAS to miniSAS 1m Cable | 419570-B21 | |
| HP SAS to miniSAS 2m Cable | 419571-B21 | |
| SAS Cables (SAS to SAS) Older MSA2000fc controller to MSA2000 3.5-inch Disk Enclosure or cascading two MSA2000 3.5-inch Disk Enclosures if included .6m cables is not of sufficient length |
||
| HP Ext SAS to SAS 1m Cable | 389665-B21 | |
| HP Ext SAS to SAS 2m Cable | 389668-B21 | |
|
|
||
| Step 3 - Other MSA2300fc Options | ||
| Description |
Quantity
|
Part Number
|
|
1st generation HP StorageWorks 2000fc Modular Smart Array Controller (older version) |
1 or 2
|
AJ744A
|
|
(ONLY for those desiring to configure an older MSA2012fc by using the MSA2012 chassis and installing either one or two of this model controller. The resulting array head will have the attributes of the first generation MSA2012fc with no support for SFF drives, no HP-UX, limited total drive count, limited snaps, etc.) |
||
|
Choose optional Power Cord for Non-U.S. Configurations |
||
| Power Cord, 220/240 VAC, (US/Canada/Mexico) |
2
|
227099-001
|
| Power Cord, (Australia/China/New Zealand) |
2
|
227098-001
|
| Power Cord, (Central Europe) |
2
|
157215-001
|
| Power Cord, (United Kingdom/Hong Kong) |
2
|
157216-001
|
| Power Cord, (Switzerland) |
2
|
157219-001
|
| Power Cord, (Italy) |
2
|
157217-001
|
| Power Cord, (Denmark) |
2
|
157218-001
|
| Power Cord, (Japan) |
2
|
139867-001
|
| Power Cord, (South East Asia/India) |
2
|
157220-001
|
| Management Cable | ||
| HP MSA2 DB9 Controller Management cable (1 included) | AP761A | |
|
|
||
|
Step 4 - Choose Supported Options For Fibre Channel Infrastructure |
|||
|
Fibre Channel |
Model | Description |
Part Number
|
| FC2242SR | 4Gb PCI-E Dual Channel HBA for Windows and Linux |
A8003A
|
|
| FC2142SR | 4Gb PCI-E for Windows and Linux |
A8002A
|
|
| FC2243 | 4Gb PCI-X Dual Channel for Windows and Linux |
AD168A
|
|
| FC2143 | 4Gb PCI-X 2.0 for Windows and Linux |
AD167A
|
|
| FC1242SR | 4Gb PCI-E Dual Channel HBA for Windows and Linux | AE312A | |
| FC1142SR | 4Gb PCI Express HBA for Windows and Linux | AE311A | |
| FC1243 | 4Gb PCI-X 2.0 Dual Channel for Windows and Linux | AE369A | |
| FC1143 | 4Gb PCI-X 2.0 for Windows and Linux | AB429A | |
| Bladeserver HBA | Lpe1105-HP 4Gb FC HBA for HP c-Class BladeSystem | 403621-B21 | |
| Bladeserver HBA | QMH2462 4Gb FC HBA for HP c-Class BladeSystem Windows and Linux |
403619-B21
|
|
| Bladeserver HBA | QLogic QMH4062 1GbE iSCSI Adapter for HP BladeSystem c-Class, Windows and Linux | 488074-B21 | |
| 81E | StorageWorks 8Gb, PCIe to Fibre Channel Host Bus Adapter for Windows, Windows Server, and Linux |
AJ762A
|
|
| 82E | StorageWorks 8Gb, PCIe to Fibre Channel Host Bus Adapter for Windows, Windows Server, and Linux |
AJ763A
|
|
| 81Q | StorageWorks 8Gb, PCIe to Fibre Channel Host Bus Adapter for Windows, Windows Server, and Linux |
AK344A
|
|
| 82Q | StorageWorks 8Gb, Dual Channel PCIe to Fibre Channel Host Bus Adapter for Windows, Windows Server, and Linux |
AJ764A
|
|
| Fibre Channel Host Bus Adapters - Integrity, PA-Risc servers |
Integrity and HP9000 HP-UX v3 and v2 |
HP PCI-X 2.0 1Port 4Gb | AB378B |
| Integrity and HP9000 HP-UX v3, and v2 |
HP PCI-X 2.0 2Port 4Gb Fibre Channel HBA | AB379B | |
| Integrity HP-UX v3 and v2 |
HP PCIe 2Port 4Gb Fibre Channel HBA | AD300A | |
| Integrity server blades BL860c
and BL870c HP-UX v3 and v2 |
HP BLc QLogic QMH2462 FC HBA Opt Kit | 403619-B21 | |
| Integrity HP-UX v3 and v2 |
HP PCIe 1Port 4Gb Fibre Channel HBA | AD299A | |
| Integrity HP-UX v3 and v2 |
HP PCIe 2-Port 4Gb Fibre Channel HBA | AD335A | |
| Integrity server blades BL860c
and BL870c HP-UX v3 |
HP BLc Emulex LPe1105 FC HBA Opt Kit | 403621-B21 | |
| Integrity HP-UX v3 |
HP PCIe 1p 4Gb FC and 1p 1000BT Adapter | AD221A | |
| Integrity HP-UX v3 |
HP PCIe 2p 4Gb FC and 2p 1000BT Adapter | AD222A | |
| Integrity HP-UX v3 |
HP PCIe 2p 4Gb FC and 2p 1000BSX Adapter | AD393A | |
| Integrity and HP9000 HP-UX v3 and v2 |
PCI-X 2Gb Fibre Channel/1000Base-SX HBA | A9782A | |
| Integrity and HP9000 HP-UX v3 and v2 |
HP PCI-x 1p 4Gb FC and 1p 1000BT Adapter | AD193A | |
| Integrity and HP9000 HP-UX v3 and v2 |
HP PCI-x 2p 4Gb FC and 2p 1000BT Adapter | AD194A | |
| Fibre Channel Switches | Brocade 4/12 SAN Switch for HP c-Class Blade System, Base |
AE370A
|
|
| Brocade 4/24 SAN Switch for HP c-Class Blade System, Full Fabric |
AE372A
|
||
| Brocade 4/24 SAN Switch for HP c-Class Blade System, Power Pack |
AE371A
|
||
| HP StorageWorks 4/8 Base SAN Switch |
A7984A
|
||
| HP StorageWorks 4/16 SAN Switch | A7985A | ||
| HP StorageWorks 4/16 SAN Switch Power Pack | A7987A | ||
| HP StorageWorks 4/8 SAN Switch | A8000A | ||
| HP StorageWorks 4/32B Base SAN Switch | AG756A | ||
| HP StorageWorks 4/32B Full SAN Switch | AG757A | ||
| HP StorageWorks 4/32B Power Pack SAN Switch | AG758A | ||
| HP StorageWorks 8/8 Base SAN Switch | AM866A | ||
| HP StorageWorks 8/8 SAN Switch | AM867A | ||
| HP StorageWorks 8/24 Base SAN Switch | AM868A | ||
| HP StorageWorks 8/40 Base SAN Switch | AM869A | ||
| HP StorageWorks 8/40 Power Pack+ SAN Switch | AM870A | ||
| HP StorageWorks 8/80 Power Pack+ SAN Switch | AM872A | ||
| HP StorageWorks 8/80 Base SAN Switch | AM871A | ||
| HP StorageWorks 4/256 SAN Director | A7988A | ||
| HP StorageWorks 4/256 Power Pack SAN Director |
A7989A
|
||
| HP StorageWorks DC SAN Backbone Director | AK857A | ||
| Brocade 8/12c SAN Switch for HP BladeSystem c-Class | AJ820A | ||
| Brocade 8/24c SAN Switch for HP BladeSystem c-Class | AJ821A | ||
| Brocade 8/24c SAN Switch for HP BladeSystem c-Class Power Pack+ | AJ822A | ||
| 8 Gb Simple SAN Connection |
|
||
| HP StorageWorks 8/20q Fibre Channel Switch (8 switch ports active) |
AQ233A
|
||
| HP StorageWorks 8Gb Simple SAN Connection Kit (8 switch ports active) |
AK241A
|
||
| HP StorageWorks 8/20q Fibre Channel Switch (16 switch ports active) |
AK242A
|
||
| Cisco MDS 9124 8-ports Active Fabric Switch |
AG646A
|
||
| Cisco MDS 9124 16-ports Active Fabric Switch | AG647A | ||
| Cisco MDS 9124 24-ports Active Fabric Switch | AG648A | ||
| Cisco MDS 9124e 12-port Fabric Switch for HP c-Class BladeSystem | AG641A | ||
| Cisco MDS 9124e 24-port Fabric Switch for HP c-Class BladeSystem | AG642A | ||
| Cisco MDS 9134 24-ports Active Fabric Switch | AG874A | ||
| Cisco MDS 9134 32-ports Active Fabric Switch | AG875A | ||
| Cisco MDS 9134 26-ports Active w/kit for 48 port solution |
AJ732A
|
||
| Cisco MDS 9134 34-ports Active w/kit for 64 port solution | AJ733A | ||
| MDS 9222i Multiservice Modular Switch w/0 SFPs | AG851A | ||
| Cisco MDS 9216i w/o Ethernet SFP switch | AE390A | ||
| Cisco MDS 9216i | AE390A | ||
| MDS 9506 Director with Supervisor 2 | AE388A | ||
| MDS 9509 Director with Supervisor 2 | AE389A | ||
| MDS 9513 Director with Supervisor 2 | AE376A | ||
| MDS 9513 Director with Fabric 2 Module | AJ905A | ||
| Fibre Channel Cables | 2 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B21
|
|
| 5 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B22
|
||
| 15 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B23
|
||
| 30 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B26
|
||
| 50 m LC-LC Multi-Mode Fibre Channel Cable |
221692-B27
|
||
| 2 m LC-SC Multi-Mode Fibre Channel Cable |
221691-B21
|
||
| 5 m LC-SC Multi-Mode Fibre Channel Cable |
221691-B22
|
||
| 15 m LC-SC Multi-Mode Fibre Channel Cable |
221691-B23
|
||
| 30 m LC-SC Multi-Mode Fibre Channel Cable |
221691-B26
|
||
| 50 m LC-SC Multi-Mode Fibre Channel Cable |
221691-B27
|
||
|
|
|||
|
Step 5 - Choose Rack Options |
||
|
Select each required option with quantities specified.
|
||
|
Rack Cabinet, Customer Assembled
|
||
|
5642 - 5000 Series rack
|
358254-B21
|
|
|
14U rack
|
||
|
HP S10614 Rack with Shock Pallet
|
292302-B22
|
|
|
Rack Cabinets 10622 G2
|
||
|
10622 G2 Universal Rack w/Shock Pallet
|
AF022A
|
|
|
10622 G2 Universal Rack w/Standard Pallet
|
AF021A
|
|
| Rack Cabinets under 10636 G2 | ||
| 10636 G2 (36U) Rack Cabinet - Pallet |
AF011A
|
|
| 10636 G2 (36U) Rack Cabinet - Shock Pallet |
AF012A
|
|
| 10636 G2 (36U) Rack Cabinet - Crated |
AF013A
|
|
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet |
AF014A
|
|
| Rack Cabinets 10642 G2 | ||
| 10642 G2 (42U) Rack Cabinet - Pallet |
AF001A
|
|
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A
|
|
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A
|
|
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet |
AF004A
|
|
| Modular Cooling System G2 (MCS G2) | AF025A | |
| MCS G2 10642 G2 Expansion Rack | AF026A | |
| Rack Cabinets 10842 G2 | ||
| 10842 G2 Universal Rack w/Shock Pallet |
AF042A
|
|
| 10842 G2 Universal Rack w/Standard Pallet |
AF041A
|
|
| Rack Cabinets 10647 G2 | ||
| 10647 Rack G2 Pallet |
AF031A
|
|
|
|
Technical Specifications
| MSA2000fc G2 | POWER REQUIREMENTS | |
| Input Power Requirements (typ) |
110 VAC 3.6A/394W; 220VAC 1.9/385W | |
| Max Input Power | 100-240 VAC, 50/60 Hz., 4.5-1.9A; 48-60 VDC 10.4A/8.3A | |
| Heat Dissipation | 1622 BTU/hr | |
| TEMPERATURE AND HUMIDITY RANGES | ||
| Operating Temperature | 41°F to 104°F (5oC to 40°C) | |
| Shipping Temperature | -40°F to 158°F (-40°C to 70°C) | |
| Operating Humidity | 10% to 90% RH @ 104°F (40°C) non-condensing | |
| Non-Operating Humidity | Up to 93% RH @ 104°F (40°C) | |
| DECLARED ACOUSTIC NOISE LEVELS | ||
| Sound Power | < 6.5 Bels | |
| Sound Pressure | < 57 dBA | |
| SHOCK AND VIBRATION | ||
| Shock, Operational | 5G's for 11 milliseconds, half sine | |
| Shock, Non-Operational | 15G 11ms half sine | |
| Vibration, Operational | 5-500Hz, 0.21Grms flat spectrum0.000089g2/HZ Random Vibration | |
| Vibration, Non-Operational | 5-500-5Hz, 0.5 G peak to peak, sinusoidal | |
| PHYSICAL | ||
| Height | 3.436 in/ 8.727 cm | |
| Depth (excluding cables) (back of ear to back of controller handle) | MSA2024: 20.28 in / 51.510 cm
MSA2012: 21.8 in. / 55.372 cm |
|
| Width (body only) | 17.55 in / 44.58 cm (w/ ears 19 in / 48.26 cm) | |
| Chassis Weight (no controllers) |
MSA2012 chassis: 44 lbs. MSA2024 chassis: 43 lbs | |
|
Modular SAN Array 2300fc G2 Controller |
User Interface | - Status and activity provided via management interfaces Status Indicators on front of Controller |
| RAID Support | 0, 1, 3, 5, 6, 10, 50 | |
| Cache Memory | 1GB Read/Write. ECC protection with backup to Flash memory (indefinite backup) | |
| Cache Backup | ECC protection with back up to flash memory (indefinite backup) | |
| Upgradeable Firmware | yes | |
| Disk Drive and Enclosure Protocol Support | 3 Gb SAS - Serial Attached SCSI / 3 Gb SATA II | |
| Expansion Port | MSA2000fc SAS (SFF8470) 4x lane
3 Gb SAS MSA2300fc SAS (SFF8088) 4x lane 3 Gb SAS |
| Regulatory |
Safety |
UL 60950-1 (USA)
|
|
CAN/CSA-C22.2 No.60950-1-03 (Canada)
|
||
|
EN 60950-1 (European Union)
|
||
|
IEC 60950-1 ( International )
|
||
|
Electromagnetic Compatibility
|
VCCI:2008-04 Class A
|
|
|
ICES-003 Issue 4 Class A (Canada)
|
||
|
EN55022 : (European Union Class A); CISPR 22 (International)
|
||
|
EN61000-3-2 : (Harmonics)
|
||
|
EN61000-3-3 : (Flicker)
|
||
| EN 55024 (European Union, Immunity);CISPR 24 (International Immunity) | ||
|
CNS 13438 Taiwan
|
||
|
KN22 Class A (Emissions); KN24 (Immunity)
|
||
| RoHS and WEEE |
RoHS-5 Compliance, China RoHS, WEEE
|
|
| Country Approvals |
Australia/New Zealand, Canada, China (PRC), European Union,
Germany (GS Mark), Japan, South Korea, Taiwan, United States
|
|
© Copyright 2009 Hewlett-Packard Development Company, L.P. |