Overview
|
HP ProLiant DL160 Generation 6 (G6) |
|||
| The HP ProLiant DL160 G6 server is a high performance, low cost, ultra-dense, dual processor capable, 1U rack server for memory intense High Performance Computing (HPC) environments, Web 2.0, hosting, and general large memory footprint server deployments. | |||
| Hot Plug SAS/SATA and Non-Hot Plug SATA Models | |||
|
|
![]() |
||
| Front View: | Rear View: | ||
| 1. | Access panel | 1. | Power Supply Cable Socket |
| 2. | System fans | 2. | Video Port |
| 3. | Two USB ports | 3. | Serial Port |
| 4. | Power on/off & system LEDs | 4. | Rear USB ports (2) |
| 5. | Optional 3rd and 4th 3.5" Non-Hot plug SATA or hot plug SAS/SATA hard drive bays | 5. | One GbE LAN ports for shared NIC 2 (RJ-45) |
| 6. | Optional DVD-RW or DVD-ROM drive | 6. | Optional LO100i 10/100 Mbps LAN port for dedicated IPMI management (RJ-45) |
| 7. | Standard 1st and 2nd 3.5" Non-Hot plug SATA or hot plug SAS/SATA hard drive bays (Small Form Factor drive cage not shown here. See the Storage Section for orientation of eight small form factor drive option) | 7. | Low-Profile slot cover (not used in this model) |
| 8. | Full-height PCI-Express x16 | ||
| 9. | UID - Rear Unit Identification LED | ||
| 10. | One GbE LAN ports for NIC 1 (RJ-45) | ||
| 8. | Eighteen DIMM slots : DDR3 Registered (RDIMM) or Unbuffered (UDIMM) memory | ||
| 9. | Expansion Slots: Slot 1:Full-length/Full height x16 PCI-Express Gen2 slot, or Slot 1: Half-length/Full height x16 PCI-Express Gen2 slot and Slot 2: Low Profile x4 PCI-Express Gen2 slot (accepts x8 cards, internal only) |
||
| 10. | Six Core Intel® Xeon® 5600 ,Quad-Core Intel® Xeon® 5600 & Quad-Core Intel® Xeon® 5500 series processors (supports up to two) | ||
| 11. | Power supply (500 Watts - standard, other PS options available) | ||
|
|
|||
| What's New |
|
|
|
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor One of the following depending on Model |
Six -Core Processors |
| Intel® Xeon® X5690 (3.46GHz/6-core/12MB/130W,
DDR3-1333, HT, Turbo1/1/1/1/1/2/2) Processor NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Intel® Xeon® X5680 (3.33GHz/6-core/12MB/130W, DDR3-1333, HT, Turbo 1/1/2/2/3/) Processor | |
| Intel® Xeon® X5675 (3.06GHz/6-core/12MB/95W,
DDR3-1333, HT, Turbo 2/2/2/2/3/3) Processor NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Intel® Xeon® X5670 (2.93GHz/6-core/12MB/95W, DDR3-1333, HT, Turbo 2/2/2/2/3/3) Processor | |
| Intel® Xeon® X5660 (2.80GHz/6-core/12MB/95W,
DDR3-1333, HT, Turbo 2/2/2/2/3/3) Processor NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Intel® Xeon® X5650 (2.66GHz/6-core/12MB/95W, DDR3-1333, HT, Turbo 2/2/2/2/3/3) Processor | |
| Intel® Xeon® E5649 (2.53GHz/6-core/12MB/80W,
DDR3-1333, HT, Turbo 1/1/1/1/2/2) Processor NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Intel® Xeon® E5645 (2.40GHz/6-core/12MB/80W,
DDR3-1333, HT, Turbo 1/1/1/1/2/2) Processor NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Intel® Xeon® L5640 (2.26GHz/6-core/12MB/60W,
DDR3-1333, HT, Turbo 2/2/3/3/4/4) Processor NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Quad -Core Processors | |
| HP DL160 G6 Intel® Xeon®
X5687 (3.60GHz/4-core/12MB/130W, DDR3-1333, HT, Turbo NA/NA/1/1/2/2) Processor NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| HP DL160 G6 Intel® Xeon® X5677 (3.46GHz/4-core/12MB/130W, DDR3-1333, HT, Turbo 2/2/3/3) Processor | |
| HP DL160 G6 Intel® Xeon®
X5672 (3.20GHz/4-core/12MB/95W, DDR3-1333, HT, Turbo NA/NA/2/2/3/3) Processor NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Intel® Xeon® Processor X5570 (2.93GHz/4-core/8MB/95W, DDR3-1333, HT, Turbo 2/2/3/3) Processor | |
| Intel® Xeon® X5560 (2.80GHz/4-core/8MB/95W, DDR3-1333, HT, Turbo 2/2/3/3) Processor | |
| Intel® Xeon® X5550 (2.66GHz/4-core/8MB/95W, DDR3-1333, HT, Turbo 2/2/3/3) Processor | |
| Intel® Xeon® E5640 (2.66GHz/4-core/12MB/80W, DDR3-1066, HT, Turbo 1/1/2/2) Processor | |
| Intel® Xeon® E5630 (2.53GHz/4-core/12MB/80W, DDR3-1066, HT, Turbo 1/1/2/2) Processor | |
| Intel® Xeon® E5620 (2.40GHz/4-core/12MB/80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® E5607 (2.26GHz/4-core/8MB/80W,
DDR3-1066) Processor NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Intel® Xeon® E5606 (2.13GHz/4-core/8MB/80W, DDR3-1066) Processor | |
| Intel® Xeon® E5603 (1.60GHz/4-core/4MB/80W,
DDR3-1066) Processor NOTE: Available through Configure To Order only. See Factory Integration Models section for more details. |
|
| Intel® Xeon® E5540 (2.53GHz/4-core/8MB/80W, DDR3-1066, HT, Turbo 1/1/2/2) Processor | |
| Intel® Xeon® E5530 (2.40GHz/4-core/8MB/80W, DDR3-1066, HT, Turbo 1/1/2/2) Processor | |
| Intel® Xeon® E5520 (2.26GHz/4-core/8MB/80W, DDR3-1066, HT, Turbo 1/1/2/2) Processor | |
| Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W, DDR3-1066, HT, Turbo 1/1/2/2/) Processor | |
| Intel® Xeon® L5520 (2.26GHz/4-core/8MB/60W, DDR3-1066, HT, Turbo 1/1/2/2) Processor | |
| Intel® Xeon® E5506 (2.13GHz/4-core/4MB/80W, DDR3-800) Processor | |
| Intel® Xeon® E5504 (2.00GHz/4-core/4MB/80W, DDR3-800) Processor | |
| Dual Core Processors | |
| Intel® Xeon® E5503 (2.0GHz/2-core/4MB/80W, DDR3-800) Processor | |
| NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology. NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5000 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. |
|
|
|
|
| Cache Memory One of the following depending on Model |
12 MB Level 3 cache |
| 4MB Level 3 cache | |
|
|
|
| Chipset | Intel® 5520 Chipset |
|
|
|
| Upgradeability | Upgradeable to two processors |
|
|
|
| Memory Protection | Advanced memory protection |
| Mirroring Mode | |
| Lockstep Mode | |
|
|
|
| Memory | Type | DDR3 Registered (RDIMM) or Unbuffered (UDIMM) | |
| Standard (Entry Models) | 4 GB (1 x 4 GB) RDIMMs | ||
| Standard (Base Models) | 8 GB (2 x 4 GB) RDIMMs | ||
| Standard (Performance Models) | 12 GB (3 x 4 GB) RDIMMs | ||
| Maximum (RDIMM) | 288 GB (18 x 16 GB) | ||
| Maximum (UDIMM) | 48 GB (12 x 4 GB) | ||
| NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator. | |||
|
|
|||
| Network Controller | HP NC362i Integrated Dual Port Gigabit Server Adapter |
|
|
|
| Expansion Slots # |
Technology
|
Bus Width
|
Connector Width*
|
Bus Number*
|
Device No.**
|
Form Factor
|
Notes
|
| 1 |
PCI-Express 2.0
|
x16
|
x16
|
1
|
0
|
Full length, full height
|
3.3 volts
|
| 2*** | PCI-Express 2.0 | x4 | x8 | 6 | 3 | Low Profile, Internal Only | 3.3 volts |
| * Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number. | |||||||
| ** Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest Device ID by bus (starting with the lowest bus). | |||||||
| ***In order to access expansion slot #2, the low profile internal only slot, expansion slot #1 may only be populated with a half length, full height form factor card. | |||||||
|
|
|||||||
| Storage Controller | Non-Hot Plug and Cold Plug SATA Models | HP Smart Array B110i SATA RAID NOTE: Embedded SATA controller support transfer rate up to 3Gb/s NOTE: To enable RAID for embedded SATA controller, use EZ set-up CD to download driver, hpahcisr.sys, is part of the 8.20 PSP, Smart Start, EZSetup CD. For more information on SW Smart Array, go to: www.hp.com/go/sataraid NOTE: A diskette drive or virtual FDD using LO100 Advanced Pack is needed to install storage controller drivers during a Windows operating system installation from a CD. NOTE: The addition of a Smart Array hardware based storage controller to a Non-Hot Plug SATA Model is only supported for external storage. NOTE: Non VMware Support for software RAID. A Smart Array controller with hw RAID must be used to support ESX. NOTE: To enable Hot plug functionality , use HP Smart Array Hot Plug Advance Pack for B110i (PN TC421A) |
| Hot Plug SATA/SAS Models | HP Smart Array P410 Controller
(RAID 0/1/1+0) NOTE: Support transfer rate up to 6Gb/s SAS or 3Gb/s SATAHP Smart Array P410 Controller 256 BBWC (RAID/0/1/1+0/5/5+0) NOTE: Support transfer rate up to 6Gb/s SAS or 3Gb/s SATA |
|
| NOTE:
Available upgrades: P410 with FBWC, 256MB with BBWC, 512MB with FBWC, Battery
kit upgrade (for the 256MB cache), and Smart Array Advanced Pack (SAAP). NOTE: A minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade (P/N: 516471-B21) is required to enable RAID 6, 6+0 NOTE: To achieve highest possible stated transfer rate please make sure the firmware on the drive bays (backplanes) and HP Smart Array controller up to date. Latest firmware is available to download from HP support web site. NOTE: HP Smart Array B110i does not support greater than 2TB hard drive. |
||
|
|
||
| Internal Storage Devices | Diskette Drives | Via USB only |
| Optical Drives | Optional SATA 9.5mm DVD-ROM Optical Drive | |
| Optional SATA 9.5mm DVD RW Optical Drive | ||
| Drive Bays One of the following depending on Model |
Up to 4 Non-hot plug SATA 3.5" drives | |
| Up to 4 Hot plug SAS/SATA 3.5" drives | ||
| Up to 8 Hot plug SAS/SATA 2.5" drives | ||
|
|
||
| Maximum Internal
Storage One of the following depending on Model |
Non-Hot Plug LFF SATA | 12.0TB | 4 x 3TB |
| Hot Plug LFF SATA | 12.0TB | 4 x 3TB | |
| Hot Plug LFF SATA SSD | 1.6TB | 4 x 400GB | |
| Hot Plug LFF SAS | 8.0TB | 4 x 2TB | |
| Hot Plug SFF SATA | 8.0TB | 8 x 1TB | |
| Hot Plug SFF SATA SSD | 3.2TB | 8 x 400GB | |
| Hot Plug SFF SAS | 8.0TB | 8 x 1TB | |
| Hot Plug SAS SSD | 6.4TB | 8 x 800GB | |
|
|
|||
| Interfaces | Parallel | None |
| Network RJ-45(Ethernet) | 2 10/100/1000 NIC ports (plus 1 optional dedicated port for the HP ProLiant Lights-Out 100i Remote Management) | |
| Serial | 1 | |
| Pointing Device (Mouse) | 0 (via USB only) | |
| Graphics | 1 | |
| Keyboard | 0 (via USB only) | |
| USB | 5 (two front, one internal,
two rear) NOTE: In order to connect a USB device internally, the internal USB Cable G6 Kit must be used (536769-B21) NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
|
|
||
| Industry Standard Compliance | ACPI V2.0 Compliant |
| PCI 2.2 Compliant | |
| PXE Support | |
| WOL Support | |
| Microsoft® Logo certifications | |
| IPMI 2.0, SMASH CLP, DCMI 1.0 compliant | |
|
|
|
| Server Power Cords | One 6' Highline (IEC-IEC) power
cord ships standard NOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (163719-002) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the NEMA power cord (227099-001) must be ordered separately. If customers require a local power cord, they can check the power cord matrix for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix. |
|
|
|
| Power Supply | 500 Watts, auto-switching, high efficiency, PFC (Power Factor Correcting) |
| NOTE: Factory
upgradeable to high-efficiency hot plug common slot or redundant hot-plug
power supply. NOTE: It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your needs. HP Power Advisor can be accessed at: www.hp.com/go/hppoweradvisor. |
|
|
|
|
| System Fans | 6 system fans ship standard;
Non-hot plug, N+1 Redundant Standard NOTE: Fan redundancy is not available when 130W processors are installed. |
|
|
|
| Operating Systems and Virtualization Software Support for ProLiant Servers |
Microsoft
Windows Server |
| NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/ossupport and our driver download page http://www.hp.com/support/DL160G6. | |
| | |
| Graphics |
32MB shared supporting all display resolutions up to 1600x1200 16bpp@75Hz |
|
|
|
| Form Factor | Rack (1U), (1.75 in/4.45 cm) |
|
|
|
| Embedded Systems Management |
HP Lights-Out 100 (LO100) Advanced |
HP LO100 with Optional LO100 Advanced Licenses for Virtual KVM and Virtual
Media.
NOTE: For more information, see: http://www.hp.com/go/lo100 |
|
|
||
| Security | Power-on password Setup password Diskette boot control Secure Sockets Layer (SSL) Secure Shell (SSH) |
|
|
|
| Warranty | This product is covered by a
global limited warranty and supported by HP Services and a worldwide network
of HP Authorized Channel Partners. Hardware diagnostic support and parts
replacement is available for three years from date of purchase. Support
for software and initial setup is available for 90 days from date of purchase.
Enhancements to warranty services are available through HP Care Pack services
or customized service agreements. Hard drives have either a one year or
three year warranty; refer to the specific hard drive QuickSpecs for details. NOTE: Server Warranty includes 3 year Next Day Parts replacement, 0-Years Labor, 0-Years Onsite support (3-1-1 warranty in APJ). Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html. |
|
|
Optional Features
| HP Insight management software | HP Insight Control for Linux |
HP Insight Control for Linux, as a product option, delivers essential
lifecycle management that can help save time and money by integrating
discovery, server deployment, firmware updates & provisioning, health
& performance management, remote management, and virtualization. This
makes it easy to optimize your IT infrastructure through a single, simple
management console. The IC-Linux installs and licenses software modules
that are integrated into HP System Insight Manager (HP SIM). |
| Insight Control server deployment | HP Insight Control server deployment is a
deployment solution for HP ProLiant and Integrity servers hosted on a Windows
CMS. It automates the process of deploying and provisioning server software,
enabling companies to quickly and easily adapt to changing business demands.
Insight Control server deployment includes software optimizations for HP
servers, including the HP scripting toolkits, configuration jobs for leading
industry-standard operating systems, sample unattended files, and HP server
support packs that include software drivers, management agents, and important
documentation. Deploying servers can be accomplished either through imaging
or through scripting. Insight Control server deployment is hosted on a Windows server and is intended for heterogeneous environments deploying Windows, Linux, VMware ESX and Microsoft Hyper-V systems. Insight Control server deployment includes one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates. For more information about this service, please visit: http://www.hp.com/services/insight. |
|
| Core Infrastructure Management | HP Systems Insight Manager | HP Systems Insight Manager (HP SIM) provides
a unified, secure and extensible standards-based environment to centrally
manage servers, storage and other infrastructure devices, (both HP and non-HP)
across multiple operating system platforms. For additional information, please see: http://www.hp.com/go/insight. |
| Subscriber's Choice | Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for ProLiant products. Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. | |
| ROMPaq, software and latest drivers |
The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options; downloaded from Software and Drivers download pages website at: http://www.hp.com/go/support and from www.hp.com/servers/easysetup. Contains the following:
|
|
|
|
||
| High Performance Clusters | HP Cluster Platforms |
HP Cluster Platforms are specifically engineered, factory-integrated large-scale ProLiant clusters optimized for High Performance Computing, with a choice of servers, networks and software. Operating system options include specially priced offerings for Red Hat Enterprise Linux and SUSE Linux Enterprise Server, as well as Microsoft Windows HPC Server. A Cluster Platform Configurator simplifies ordering. http://www.hp.com/go/clusters |
| HP HPC Interconnects | High Performance Computing (HPC) interconnect technologies are available for this server as part of the HP Cluster Platform portfolio. These high-speed InfiniBand and Gigabit interconnects are fully supported by HP when integrated within an HP cluster. Flexible, validated solutions can be defined with the help of configuration tools. http://www.hp.com/techservers/clusters/ucp/index.html | |
| HP Insight Cluster Management Utility | HP Insight Cluster Management Utility (CMU) is an HP-licensed and HP-supported suite of tools that are used for lifecycle management of hyperscale clusters of Linux ProLiant systems. CMU includes software for the centralized provisioning, management and monitoring of nodes. CMU makes the administration of clusters user friendly, efficient, and effective. http://www.hp.com/go/cmu | |
| HP HPC Linux Value Pack | HP HPC Linux Value Pack (Value Pack) is an HP-licensed and HP-supported option to HP Insight CMU, for the development and deployment of applications on HPC Cluster Platforms. Value Pack includes the Platform LSF workload scheduler and Platform Application Center, as well as the HP-MPI parallelization library. HP HPC Linux Value Pack | |
|
|
||
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed. |
| | |
| HP Enterprise Configurator |
The HP eConfigure Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator. |
|
|
Service and Support
| Service and Support |
HP Technology Services for Industry Standard Servers and BladeSystem |
|
|
|
| Optimized Care Package | Supports maintaining servers
at optimum performance availability HP ProLiant Server Hardware Installation Provides for the basic hardware installation of HP branded servers, storage devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner. http://h20195.www2.hp.com/V2/GetPDF.aspx/5981-9356EN.pdf 3-Year HP 6 hour Hardware Support Onsite Call-to-Repair Service Provides an IT manager with a team of support specialists who will quickly begin troubleshooting the system to help return the hardware to operating condition within 6 hours of the initial service request to the HP Global Solution Center. http://h20195.www2.hp.com/V2/GetPDF.aspx/5982-6547EN.pdf Additional Services: Software OS (Microsoft, Linux (SUSE/Red Hat) Installation and Start Up and Software Support) plus Microsoft or Linux education courses +30 Proactive Select Credits, Factory Express. |
|
|
|
| Standard Care Package | Package that maintains high
level of server availability HP ProLiant Server Hardware Installation Provides for the basic hardware installation of HP branded servers, storage devices and networking options to assist you in bringing your new hardware into operation in a timely and professional manner. http://h20195.www2.hp.com/V2/GetPDF.aspx/5981-9356EN.pdf 3-Year HP 24x7 4 hour Response, Hardware Support Onsite Service Provides you with rapid remote support and if required an HP authorized representative who will arrive on site any time and day of the year to begin hardware maintenance service within 4 hours of the service request being logged. http://h20195.www2.hp.com/V2/GetPDF.aspx/5982-6547EEE.pdf Additional Services: Software OS (Microsoft, Linux (SUSE/Red Hat) Installation and Start Up and Software Support); +10 Proactive Select Credits, Factory Express. |
|
|
|
| Basic Care Package |
Delivers minimum recommended support service level |
|
|
|
| Insight Remote Support |
The packages include HP Insight Remote Support that uses proven technology to deliver secure, reliable 24x7 remote monitoring, diagnoses, and problem resolution. It is available at no additional cost to all warranty, HP Care Pack Service, and service agreement customers. |
|
|
|
| For more information |
To learn more on HP ProLiant servers and HP BladeSystem servers, please contact your HP sales representative or HP Authorized Channel Partner. Or visit: http://www.hp.com/services/proliant |
|
|
Pre-configured Models
| NOTE:
For the Standard Features shipped in the "Factory Integrated Models",
please see the "Configuration Information - Factory Integrated Models"
section. NOTE: Not all models are available in all regions. Check with your local country HP offices for availability. NOTE: Pre-configured models ship with the configurations below. Options can be selected from the Core or Additional options section of this QuickSpecs. NOTE: HP does not allow factory integration of options into pre-configured models. Any additional options purchased will be shipped separately. NOTE: If you desire a custom configuration please see "Configuration Information - Factory Integrated Models" section of this QuickSpecs. |
||
|
Hot Plug Serial ATA (SATA)/ Serial Attached SCSI (SAS)
Pre-configured Models |
||
|
HP ProLiant DL160 G6 L5630 1P 4GB-R B110i Cold Plug SATA 4 LFF 500W
PS Server |
Processor(s) | (1) Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W, DDR3-1066, HT, Turbo 1/1/2/2/) Processor |
| Cache Memory | 12 MB shared L3 cache | |
| Memory | 4GB (1 x 4GB) PC3-10600R (RDIMM) NOTE: Total of 18 DIMM slots |
|
| Network Controller | HP NC362i Integrated Dual Port Gigabit Server Adapter | |
| Storage Controller | HP Smart Array B110i SATA RAID Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | Up to 4 large form factor Pluggable drives | |
| Optical Drive | None ship standard | |
| Power Supply | 500W high efficiency multi-output supply (ships standard) | |
| Form Factor | 1U | |
| Warranty | Server Warranty includes 3 year Next Day Parts replacement, 0-Years Labor, 0-Years Onsite support (3-1-1 warranty in APJ) | |
|
|
||
|
HP ProLiant DL160 G6 E5620 1P 8GB-R P410 SAS/SATA 4 LFF 500W PS Server |
Processor(s) | (1) Intel® Xeon® E5620 (2.40GHz/4-core/12MB/80W, DDR3-1066, HT, Turbo 1/1/2/2) Processor |
| Cache Memory | 12 MB shared L3 cache | |
| Memory | 8GB (2 x 4GB) PC3-10600R (RDIMM) NOTE: Total of 18 DIMM slots |
|
| Network Controller | HP NC362i Integrated Dual Port Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410 Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | Up to 4 large form factor Hot Plug drives | |
| Optical Drive | None ship standard | |
| Power Supply | 500W high efficiency multi-output supply (ships standard) | |
| Form Factor | 1U | |
| Warranty | Server Warranty includes 3 year Next Day Parts replacement, 0-Years Labor, 0-Years Onsite support (3-1-1 warranty in APJ) | |
|
|
||
|
HP ProLiant DL160 G6 X5650 2P 24GB-R P410/256 BBWC 8 SFF 500W PS Server |
Processor(s) | (2) Intel® Xeon® X5650 (2.66GHz/6-core/12MB/95W, DDR3-1333, HT, Turbo 2/2/3/3/4/4) Processor |
| Cache Memory | 12MB shared L3 cache | |
| Memory | 24GB (6 x 4GB) PC3-10600R (RDIMM) NOTE: Total of 18 DIMM slots |
|
| Network Controller | HP NC362i Integrated Dual Port Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410/ 256MB BBWC | |
| Hard Drive | None ship standard | |
| Internal Storage | Up to 8 Small form factor Hot Plug drives | |
| Optical Drive | None ship standard | |
| Power Supply | 500W high efficiency multi-output supply (ships standard) | |
| Form Factor | 1U | |
| Warranty | Server Warranty includes 3 year Next Day Parts replacement, 0-Years Labor, 0-Years Onsite support (3-1-1 warranty in APJ) | |
|
|
||
|
HP ProLiant DL160 G6 E5606 1P 4GB-R 500W PS Entry Server |
Processor(s) | (1) Intel® Xeon® E5606 (2.13GHz/4-core/8MB/80W, DDR3-800) Processor |
| Cache Memory | 8 MB shared L3 cache | |
| Memory | 4GB (1 x 4GB) PC3-10600R (RDIMM) NOTE: Total of 18 DIMM slots |
|
| Network Controller | HP NC362i Integrated Dual Port Gigabit Server Adapter | |
| Storage Controller | HP Smart Array B110i SATA RAID Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | Up to 4 large form factor Pluggable drives | |
| Optical Drive | None ship standard | |
| Power Supply | 500W high efficiency multi-output supply (ships standard) | |
| Form Factor | 1U | |
| Warranty | Server Warranty includes 3 year Next Day Parts replacement, 0-Years Labor, 0-Years Onsite support (3-1-1 warranty in APJ) | |
|
|
||
| Country Code Key | xx=00 | U.S. |
| xx=20 | Brazil | |
| xx=29 | Japan | |
| xx=37 | APD | |
| xx=42 | Euro | |
| xx=AA | PRC |
|
|
Configuration Information - Factory Integrated Models
|
NOTE: This section lists some of the steps required to configure
a Factory Integrated Model. To ensure only valid configurations are ordered,
HP recommends the use of an HP approved configurator. Contact your local
sales representative for information on configurable product offerings
and requirements. |
||
| Step 1: Base Configuration (choose one of the following configurable models) | ||
| HP Models | Non-Hot Plug LFF
SATA Model NOTE: Non-Hot Plug models are not upgradeable to Hot Plug. NOTE: The addition of a Smart Array controller is supported for external storage use only. |
|
| HP ProLiant DL160 G6 Non-hot Plug Configure-to-order Rack Server | 491531-B21 | |
| Factory Integrated Model ships with: | ||
| HP NC362i Integrated
Dual Port Gigabit Server Adapter Slot 1: FL /FH PCI-Express x16 Gen 2 slot or Slot 1 : HL/FH x16 PCI-Express Gen2 slot and Slot 2 : HL/LP x8 PCI-Express Gen2 slot (internal only) |
||
| One available full-length/full-height PCI-Express x16 Generation 2 slot | ||
| One Highline IEC Power Cord | ||
| 6 Non-Hot Plug Fans | ||
| Rack (1U), (1.75 in / 4.45 cm) | ||
| Tool-less Fixed Rails | ||
| 4 LFF drive cage | ||
| Hot Plug LFF Model | ||
| HP ProLiant DL160 G6 Hot Plug Configure-to-order Rack Server | 491532-B21 | |
| Factory Integrated Model ships with: | ||
| HP NC362i Integrated Dual Port Gigabit Server Adapter | ||
| Available PCI-Express
Generation 2 slots: Slot 1: PCIe 2.0 x16 (connector)/x16 (speed), half-length/full-height Slot 2: PCIe 2.0 x8 (connector)/x4 (speed), half-length/half-height |
||
| One Highline IEC Power Cord | ||
| 6 Non-Hot Plug Fans | ||
| Rack (1U), (1.75 in / 4.45 cm) | ||
| Tool-less Fixed Rails | ||
| Hot Plug SFF Model | ||
| HP ProLiant DL160 G6 8 SFF Hot Plug Configure-to-order Server | 593352-B21 | |
| Factory Integrated Model ships with: | ||
| HP NC362i Integrated Dual Port Gigabit Server Adapter | ||
| Available PCI-Express
Generation 2 slots: Slot 1: PCIe 2.0 x16 (connector)/x16 (speed), half-length/full-height Slot 2: PCIe 2.0 x8 (connector)/x4 (speed), half-length/half-height |
||
| One Highline IEC Power Cord | ||
| 6 Non-Hot Plug Fans | ||
| Rack (1U), (1.75 in / 4.45 cm) | ||
| Tool-less Fixed Rails | ||
| NOTE: SFF CTO Chassis (P/N: 593352-B21) is not configurable with 130W Intel® Xeon® Processor Models. | ||
|
|
||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| HP Processors | NOTE: If 2 processors are desired, select one xxxxxx-L21 and one xxxxxx-B21. | |
| Six-Core Processors | ||
| HP DL160 G6 Intel®
Xeon® X5690 (3.46GHz/6-core/12MB/130W) FIO Processor Kit NOTE: Not available with SFF CTO Chassis (P/N: 593352-B21) in Step 1. |
639493-L21 | |
| HP DL160 G6 Intel® Xeon® X5675 (3.06GHz/6-core/12MB/95W) FIO Processor Kit | 637345-L21 | |
| HP DL160 G6 Intel® Xeon® X5660 (2.80GHz/6-core/12MB/95W) FIO Processor Kit | 589723-L21 | |
| HP DL160 G6 Intel® Xeon® X5650 (2.66GHz/6-core/12MB/95W) FIO Processor Kit |
589721-L21
|
|
| HP DL160 G6 Intel® Xeon® E5649 (2.53GHz/6-core/12MB/80W) FIO Processor Kit |
637349-L21
|
|
| HP DL160 G6 Intel® Xeon® E5645 (2.40GHz/6-core/12MB/80W) FIO Processor Kit | 637351-L21 | |
| HP DL160 G6 Intel® Xeon® L5640 (2.26GHz/6-core/12MB/60W) FIO Processor Kit | 589700-L21 | |
| Quad-Core Processors | ||
| HP DL160 G6 Intel®
Xeon® X5687 (3.60GHz/4-core/12MB/130W) FIO Processor Kit NOTE: Not available with SFF CTO Chassis (P/N: 593352-B21) in Step 1. |
637343-L21
|
|
| HP DL160 G6 Intel® Xeon® X5672 (3.20GHz/4-core/12MB/95W) FIO Processor Kit |
637347-L21
|
|
| HP DL160 G6 Intel® Xeon® E5620 (2.40GHz/4-core/12MB/80W) FIO Processor Kit | 589711-L21 | |
| HP DL160 G6 Intel® Xeon® E5607 (2.26GHz/4-core/8MB/80W) FIO Processor Kit | 641512-L21 | |
| HP DL160 G6 Intel® Xeon® E5606 (2.13GHz/4-core/8MB/80W) FIO Processor Kit | 637250-L21 | |
| HP DL160 G6 Intel® Xeon® E5603 (1.60GHz/4-core/4MB/80W) FIO Processor Kit | 637353-L21 | |
| HP DL160 G6 Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W) FIO Processor Kit | 589698-L21 | |
|
NOTE: HT indicates that the processor model supports Intel®
Hyper-Threading Technology.
NOTE: For the Intel 5000 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. |
||
|
|
||
| HP Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500656-B21 | |
| HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit | 604504-B21 | |
| HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit |
500658-B21
|
|
| HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit |
593339-B21
|
|
| HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit | 604506-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500662-B21 | |
| HP 16GB (1x16GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 LP Memory Kit | 627812-B21 | |
| HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit |
500666-B21
|
|
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500668-B21 | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500670-B21 | |
| HP 4GB (1x4GB) Dual Rank x8 PC3L-10600 (DDR3-1333) Unbuffered CAS-9 Low Power Memory Kit | 619488-B21 | |
| HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500672-B21 | |
| NOTE:
All DDR3 memory option kits consist of one DIMM per kit. For detailed memory
configuration rules and guidelines, please use the Online DDR3 Memory Configuration
Tool: www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: http://www.hp.com/go/proliant-energy-efficient |
||
| NOTE: There is a maximum support limitation of 8 ranks per memory channel (maximum of 2 quad rank DIMMs per channel) | ||
| NOTE: PC3L is a low voltage memory. | ||
|
|
||
| HP Hard Drives | NOTE:
The components of a storage subsystem (e.g. the drive, the HBA/controller,
and the server backplane) should operate at the same data transfer rate
or the system bandwidth will be negotiated down to an acceptable level for
all components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|
| SATA Non-Hot Plug
LFF (3.5-inch) Midline (MDL) Drives NOTE: A minimum of one SATA Non-Hot Plug hard drive is required ONLY when purchasing Non-Hot Plug CTO Chassis Model (P/N 491531-B21) in Step 1. |
||
| HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty Hard Drive |
507774-B21
|
|
| HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty Hard Drive |
507772-B21
|
|
| HP 500GB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty Hard Drive | 458941-B21 | |
| SATA Non-Hot Plug LFF (3.5-inch) Entry (ETY) Drives | ||
| HP 160GB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Entry 1yr Warranty Hard Drive | 458947-B21 | |
|
|
||
| HP Storage Controllers | NOTE:
A minimum of one Smart Array Controller is ONLY required when purchasing
Hot Plug SFF CTO Chassis Model (P/N 593352-B21) in Step 1. NOTE: The below storage controllers are intended for use with internal drives in the Hot Plug CTO Chassis Model (P/N 491532-B21). |
|
| NOTE:
With the HP Smart Array P410 Controller, the addition of the battery backed
cache upgrade enables BBWC, RAID 5, 5+0, array expansion, logical drive
extension, RAID migration, and stripe size migration. In order to upgrade
to RAID 6, at least 256MB Cache and a Battery is required in addition to
the Smart Array Advanced Pack license (P/N 516471-B21). NOTE: To use the internal only PCI-e slot when purchasing the Hot Plug CTO Chassis, a HP Smart Array P410 controller must be selected. |
||
| HP Smart Array P812/1G FBWC 2-ports Int/4-ports Ext PCIe x8 SAS Controller |
487204-B21
|
|
| HP Smart Array P410/1G FBWC 2-ports Int PCIe x8 SAS Controller |
572532-B21
|
|
| HP Smart Array P410/512 FBWC 2-ports Int PCIe x8 SAS Controller | 578230-B21 | |
| HP Smart Array P410/ZM 2-ports Int PCIe x8 FIO SAS Controller | 462860-B21 | |
| HP Smart Array P410/256 BBWC 2-ports Int PCIe x8 FIO SAS Controller | 491195-B21 | |
|
|
||
| HP Hot Plug HDD Backplane Option | NOTE: A minimum of one Hot Plug HDD Backplane option is ONLY required when purchasing Hot Plug CTO Chassis Model (P/N 491532-B21) in Step 1. | |
| HP 2 HDD Backplane
G6 FIO Kit NOTE: Supports LFF hard drives only. |
518593-B21 | |
| HP 4 Hard Drive Hot
Plug Backplane G6 Kit NOTE: Supports LFF hard drives only. |
512181-B21 | |
|
|
||
| HP Power Supplies | NOTE: Prior to making a power supply selection it is highly recommended that the HP Power Advisor is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at: http://www.hp.com/go/hppoweradvisor | |
| HP 500W Factory Integrated Power Supply Kit |
515915-B21
|
|
| HP 460W Common Slot Gold Hot Plug Factory Integrated Power Supply Kit with Backplane |
535684-B21
|
|
| HP 750W Common Slot Gold Hot Plug Factory Integrated Power Supply Kit with Backplane | 535683-B21 | |
| HP 460W Common Slot Platinum Hot Plug Power Supply Kit with Backplane | 605923-B21 | |
| HP 365W Redundant
Power Supply Kit w/ Backplane NOTE: The 400W 1U G6 RPS (P/N: 532092-B21) is limited to the following configuration support: (1.) NHP SATA Model (P/N: 491531-B21), (2.) Up to 2 60W Low Voltage processors (589700-B21 (3.) Unbuffered memory (P/N: 500668-B21 or 500670-B21), 4. No graphics cards supported via PCI-e. |
532092-B21 | |
|
|
||
| Step 3: Choose Additional Factory Integratable Options | ||
| HP Storage Controllers | NOTE:
The below storage controllers are intended for use with internal drives
in the Hot Plug CTO Chassis Model (P/N 491532-B21or P/N 593352-B21). The
HP Smart Array P212 Controller (P/N 491191-B21) is supported in the Non-Hot
Plug Model (P/N 491531-B21) for external storage control ONLY. NOTE: With the HP Smart Array P410 Controller, the addition of the battery backed cache upgrade enables BBWC, RAID 5, 5+0, array expansion, logical drive extension, RAID migration, and stripe size migration. In order to upgrade to RAID 6, at least 256MB Cache and a Battery is required in addition to the Smart Array Advanced Pack license (P/N 516471-B21). NOTE: To use the internal only PCI-e slot when purchasing the Hot Plug CTO Chassis, a HP Smart Array P410 controller must be selected. When selecting the HP Smart Array P212 Controller (P/N 491191-B21), the controller will be installed in the x16 slot since it has both an internal and external port. This prevents the use of the internal slot and no PCI-E slots will be available. |
|
| HP Smart Array P212/256 BBWC 1-ports Int/1-ports Ext PCIe x8 FIO SAS Controller | 491191-B21 | |
| HP Smart Array P410/ZM 2-ports Int PCIe x8 FIO SAS Controller | 462860-B21 | |
| HP Smart Array P410/256 BBWC 2-ports Int PCIe x8 FIO SAS Controller | 491195-B21 | |
| HP Smart Array P411/256 BBWC 2-ports Ext PCIe x8 FIO SAS Controller | 491193-B21 | |
|
|
||
| Step 4: Choose Additional Options for Factory Integration |
| NOTE: For additional "Core Options" and "Additional Options", please refer to the "Options" section below. |
|
|
Core Options
| NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information. | ||
|
HP Unique Options |
HP Dedicated Management Port Kit |
516006-B21
|
|
|
||
| HP Processors | Six-Core Processors | |
| HP DL160 G6 Intel® Xeon®
X5690 (3.46GHz/6-core/12MB/130W) Processor Kit NOTE: Not supported in Small Form Factor (SFF) Models. |
639493-B21 | |
| HP DL160 G6 Intel® Xeon®
X5680 (3.33GHz/6-core/12MB/130W) Processor Kit NOTE: Not supported in Small Form Factor (SFF) Models. |
589727-B21 | |
| HP DL160 G6 Intel® Xeon® X5675 (3.06GHz/6-core/12MB/95W) Processor Kit | 637345-B21 | |
| HP DL160 G6 Intel® Xeon® X5670 (2.93GHz/6-core/12MB/95W) Processor Kit | 589725-B21 | |
| HP DL160 G6 Intel® Xeon® X5660 (2.80GHz/6-core/12MB/95W) Processor Kit | 589723-B21 | |
| HP DL160 G6 Intel® Xeon® X5650 (2.66GHz/6-core/12MB/95W) Processor Kit | 589721-B21 | |
| HP DL160 G6 Intel® Xeon® E5649 (2.53GHz/6-core/12MB/80W) Processor Kit | 637349-B21 | |
| HP DL160 G6 Intel® Xeon® E5645 (2.40GHz/6-core/12MB/80W) Processor Kit | 637351-B21 | |
| HP DL160 G6 Intel® Xeon® L5640 (2.26GHz/6-core/12MB/60W) Processor Kit | 589700-B21 | |
| Quad-Core Processors | ||
| HP DL160 G6 Intel® Xeon®
X5687 (3.60GHz/4-core/12MB/130W) Processor Kit NOTE: Not supported in Small Form Factor (SFF) Models. |
637343-B21 | |
| HP DL160 G6 Intel® Xeon®
X5677 (3.46GHz/4-core/12MB/130W) Processor Kit NOTE: Not supported in Small Form Factor (SFF) Models. |
629850-B21 | |
| HP DL160 G6 Intel® Xeon® X5672 (3.20GHz/4-core/12MB/95W) Processor Kit | 637347-B21 | |
| HP DL160 G6 Intel® Xeon® X5570 (2.93GHz/4-core/8MB/95W) Processor Kit | 508231-B21 | |
| HP DL160 G6 Intel® Xeon® X5560 (2.80GHz/4-core/8MB/95W) Processor Kit | 573893-B21 | |
| HP DL160 G6 Intel® Xeon® X5550 (2.66GHz/4-core/8MB/95W) Processor Kit | 491511-B21 | |
| HP DL160 G6 Intel® Xeon® E5640 (2.66GHz/4-core/12MB/80W) Processor Kit | 589715-B21 | |
| HP DL160 G6 Intel® Xeon® E5630 (2.53GHz/4-core/12MB/80W) Processor Kit | 589713-B21 | |
| HP DL160 G6 Intel® Xeon® E5620 (2.40GHz/4-core/12MB/80W) Processor Kit | 589711-B21 | |
| HP DL160 G6 Intel® Xeon® E5607 (2.26GHz/4-core/8MB/80W) Processor Kit | 641512-B21 | |
| HP DL160 G6 Intel® Xeon® E5606 (2.13GHz/4-core/8MB/80W) Processor Kit | 637250-B21 | |
| HP DL160 G6 Intel® Xeon® E5603 (1.60GHz/4-core/4MB/80W) Processor Kit | 637353-B21 | |
| HP DL160 G6 Intel® Xeon® E5540 (2.53GHz/4-core/8MB/80W) Processor Kit | 490461-B21 | |
| HP DL160 G6 Intel® Xeon® E5530 (2.40GHz/4-core/8MB/80W) Processor Kit | 573895-B21 | |
| HP DL160 G6 Intel® Xeon® E5520 (2.26GHz/4-core/8MB/80W) Processor Kit | 490459-B21 | |
| HP DL160 G6 Intel® Xeon® L5630 (2.13GHz/4-core/12MB/40W) Processor Kit | 589698-B21 | |
| HP DL160 G6 Intel® Xeon® L5520 (2.26GHz/4-core/8MB/60W) Processor Kit | 491507-B21 | |
| HP DL160 G6 Intel® Xeon® E5506 (2.13GHz/4-core/4MB/80W) Processor Kit | 573897-B21 | |
| HP DL160 G6 Intel® Xeon® E5504 (2.00GHz/4-core/4MB/80W) Processor Kit | 490457-B21 | |
| Dual Core Processors | ||
| HP DL160 G6 Intel® Xeon®
E5503 (2.0GHz/2-core/4MB/80W) Processor Kit NOTE: If 2 processors are desired, select one 593899-L21 and one 593899-B21. |
593899-B21 | |
| NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology. NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5000 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. |
||
|
|
||
|
HP Memory |
Registered DIMMs (RDIMMs) | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit |
500656-B21
|
|
| HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit | 604504-B21 | |
| HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit |
500658-B21
|
|
| HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit |
593339-B21
|
|
| HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit | 604506-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500662-B21 | |
| HP 16GB (1x16GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 LP Memory Kit | 627812-B21 | |
| HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit |
500666-B21
|
|
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500668-B21 | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500670-B21 | |
| HP 4GB (1x4GB) Dual Rank x8 PC3L-10600 (DDR3-1333) Unbuffered CAS-9 Low Power Memory Kit | 619488-B21 | |
| HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500672-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: http://www.hp.com/go/proliant-energy-efficient |
||
|
|
||
|
HP Drive Cage Options |
HP 4 Hard Drive Hot Plug Backplane
G6 Kit NOTE: Installation of the 4 HDD Hot Plug Backplane G6 Kit (512181-B21) is required if ordering third or fourth Hard Drives for Hot Plug models only. |
512181-B21
|
|
|
||
|
HP Optical Drives |
HP 9.5mm SATA DVD-ROM Optical Drive |
481045-B21
|
| HP 9.5mm SATA DVD-RW Optical Drive | 481047-B21 | |
| | ||
| HP Hard Drives | NOTE: The components
of a storage subsystem (e.g. the drive, the HBA/controller, and the server
backplane) should operate at the same data transfer rate or the system bandwidth
will be negotiated down to an acceptable level for all components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. NOTE: HP Smart Array B110i does not support greater than 2TB hard drive |
|
| SATA Hot Plug SFF (2.5-inch) Midline (MDL) Drives | ||
| HP 1TB 3G SATA 7.2K rpm SFF (2.5-inch) Hot Plug Midline 1yr Warranty Hard Drive | 625609-B21 | |
| HP 500GB 3G SATA 7.2K rpm SFF (2.5-inch) Midline 1yr Warranty Hard Drive | 507750-B21 | |
| SATA Hot Plug LFF (3.5-inch)
Midline (MDL) Drives (SAS/SATA Hot Plug Models Only) NOTE: A SAS HBA or Array Controller is required. |
||
| HP 3TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive | 628059-B21 | |
| HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive | 507632-B21 | |
| HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive | 454146-B21 | |
| HP 500GB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive | 458928-B21 | |
| SATA Non-Hot Plug LFF (3.5-inch)
Midline (MDL) Drives (Non-Hot Plug Models Only) |
||
| HP 3TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot plug Midline 1yr Warranty Hard Drive | 628063-B21 | |
| HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty Hard Drive |
507774-B21
|
|
| HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty Hard Drive |
507772-B21
|
|
| HP 500GB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty Hard Drive | 458941-B21 | |
| SATA Non-Hot Plug LFF (3.5-inch) Entry (ETY) Drives | ||
| HP 250GB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Entry 1yr Warranty Hard Drive |
571232-B21
|
|
| HP 160GB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Entry 1yr Warranty Hard Drive |
458947-B21
|
|
| SATA Hot Plug LFF (3.5-inch) Entry (ETY) Drives | ||
| HP 250GB 3G SATA 7.2K rpm LFF (3.5-inch) Entry 1yr Warranty Hard Drive | 571230-B21 | |
| HP 160GB 3G SATA 7.2K rpm LFF (3.5-inch) Entry 1yr Warranty Hard Drive | 458945-B21 | |
| NOTE: Please see
QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html (Worldwide) |
||
| SATA Hot Plug 2.5" Enterprise Mainstream Solid State Drives | ||
| HP 400GB 3G SATA MLC SFF (2.5-inch) Enterprise Mainstream 3yr Warranty Solid State Drive | 636597-B21 | |
| HP 200GB 3G SATA MLC SFF (2.5-inch) Enterprise Mainstream 3yr Warranty Solid State Drive | 636595-B21 | |
| HP 100GB 3G SATA MLC SFF (2.5-inch) Enterprise Mainstream 3yr Warranty Solid State Drive | 636593-B21 | |
| SATA Hot Plug 3.5" Midline (MDL) Solid State Drives | ||
| HP 400GB 3G SATA MLC LFF (3.5-inch) Enterprise Mainstream 3yr Warranty Solid State Drive | 636611-B21 | |
| HP 200GB 3G SATA MLC LFF (3.5-inch) Enterprise Mainstream 3yr Warranty Solid State Drive | 636609-B21 | |
| HP 100GB 3G SATA MLC LFF (3.5-inch) Enterprise Mainstream 3yr Warranty Solid State Drive | 636607-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information:
http://h18000.www1.hp.com/products/quickspecs/13415_div/13415_div.html (Worldwide) |
||
| SAS Hot Plug (2.5") SFF Enterprise (ENT) Drives | ||
| HP 900GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive | 619291-B21 | |
| HP 600GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive | 581286-B21 | |
| HP 450GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive | 581284-B21 | |
| HP 300GB 6G SAS 15K rpm SFF (2.5-inch) Hot Plug Enterprise 3 yr Warranty Hard Drive | 627117-B21 | |
| HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive | 507127-B21 | |
| HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive | 512547-B21 | |
| HP 72GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive | 512545-B21 | |
| SAS Hot Plug (3.5") Enterprise (ENT) Drives | ||
| HP 600GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive | 516828-B21 | |
| HP 450GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive | 516816-B21 | |
| HP 300GB 6G SAS 15K rpm LFF (3.5-inch)
Dual Port Enterprise 3yr Warranty Hard Drive NOTE: The addition of a Smart Array controller is required to support SAS hard drives. |
516814-B21 | |
| SAS Non Hot Plug (3.5") LFF Enterprise (ENT) Drives | ||
| HP 600GB 6G SAS 15K rpm LFF (3.5-inch) Non-hot Plug Dual Port Enterprise 3yr Warranty Hard Drive | 516830-B21 | |
| HP 450GB 6G SAS 15K rpm LFF (3.5-inch) Non-hot Plug Dual Port Enterprise 3yr Warranty Hard Drive | 516826-B21 | |
| HP 300GB 6G SAS 15K rpm LFF (3.5-inch)
Non-hot Plug Dual Port Enterprise 3yr Warranty Hard Drive NOTE: The addition of a Smart Array controller is required to support SAS hard drives. |
516824-B21 | |
| SAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives | ||
| HP 1TB 6G SAS 7.2K rpm SFF (2.5-inch) Dual Port Midline 1yr Warranty Hard Drive | 605835-B21 | |
| HP 500GB 6G SAS 7.2K rpm SFF (2.5-inch) Dual Port Midline 1yr Warranty Hard Drive | 507610-B21 | |
| SAS Hot Plug LFF (3.5-inch) Midline (MDL) Drives | ||
| HP 3TB 6G SAS 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive | 625031-B21 | |
| HP 2TB 6G SAS 7.2K rpm LFF (3.5-inch) Dual Port Midline 1yr Warranty Hard Drive | 507616-B21 | |
| HP 1TB 6G SAS 7.2K rpm LFF (3.5-inch) Dual Port Midline 1yr Warranty Hard Drive | 507614-B21 | |
| NOTE: The purchase of SAS HBA or array controller is required. | ||
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html (Worldwide) | ||
| 6G SAS Hot Plug Enterprise Performance Solid State Drives | ||
| HP 400GB 6G SAS SLC SFF (2.5-inch) Enterprise Performance 3yr Warranty Solid State Drive | 632494-B21 | |
| HP 200GB 6G SAS SLC SFF (2.5-inch) Enterprise Performance 3yr Warranty Solid State Drive | 632492-B21 | |
| 6G SAS Hot Plug Enterprise Mainstream Solid State Drives | ||
| HP 800GB 6G SAS MLC SFF (2.5-inch) Enterprise Mainstream 3yr Warranty Solid State Drive | 632506-B21 | |
| HP 400GB 6G SAS MLC SFF (2.5-inch) Enterprise Mainstream 3yr Warranty Solid State Drive | 632504-B21 | |
| HP 200GB 6G SAS MLC SFF (2.5-inch) Enterprise Mainstream 3yr Warranty Solid State Drive | 632502-B21 | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/14038_div/14038_div.html (Worldwide) | ||
|
|
||
| HP Networking | Gigabit Ethernet Adapters | |
| HP NC112T PCI Express Gigabit Server Adapter |
503746-B21
|
|
| HP NC360T PCI-E Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC373F PCI-E Multifunction 1000SX Gigabit Svr Adapter |
394793-B21
|
|
| HP NC373T PCI-E Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter |
458492-B21
|
|
| HP NC364T PCI-E Quad Port Gigabit Server Adapter | 435508-B21 | |
| HP NC365T 4-port Ethernet Server Adapter | 593722-B21 | |
| HP NC375T PCI Express Quad Port Gigabit Server Adapter | 538696-B21 | |
| 10 Gigabit Ethernet Adapters NOTE: A minimum of two Gigabytes (2 GB) of server memory is required per each adapter. NOTE: Direct Attach Cable (DAC) for copper environments or fiber transceivers and cables for fiber-optic environments must be purchased separately. |
||
| HP NC522SFP Dual Port 10GbE Gigabit Server Adapter | 468332-B21 | |
| HP NC523SFP 10Gb 2-port Server Adapter | 593717-B21 | |
| HP NC550SFP Dual Port 10GbE Server Adapter |
581201-B21
|
|
| HP NC552SFP 10Gb 2-port Ethernet Server Adapter | 614203-B21 | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs | ||
|
|
||
| HP InfiniBand | QLogic InfiniBand 4X QDR PCI-E G2 Dual Port HCA |
583211-B21
|
| HP InfiniBand 4X QDR ConnectX-2 PCIe G2 Dual Port HCA |
592520-B21
|
|
| HP InfiniBand 4X DDR ConnectX-2 PCIe G2 Dual Port HCA |
592521-B21
|
|
| HP 10 GbE PCI-e G2 Dual Port Network Interface Card |
516937-B21
|
|
|
Additional Options
| NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for additional information. | ||
| HP Entry Level Management | HP Lights-Out 100i (LO100i) Advanced including
1yr 24x7 Support Single Server License NOTE: For additional License Kits please see the Lights-Out 100i QuickSpecs at: www.hp.com/go/lo100 |
530521-B21 |
|
|
||
| HP Insight software | HP Insight Control for Linux | |
| HP Insight Control for Linux including 1yr
24x7 Support Electronic License NOTE: This part number can be purchased as a single license or as multiple licenses with a single activation key. Customer will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: Electronic LTUs are only available through limited points of sales; if not available, order a printed license entitlement certificate instead. |
TC213AAE | |
| HP Insight Control for Linux including 1yr 24x7 Support Single Server License | TC209A | |
| HP Insight Control for Linux Media Kit NOTE: This optional Media pack DVD contains the ISO image for HP Insight Control for Linux, HP Systems Insight Manager, HP Insight Control power management, HP Insight Control virtual machine management, and an integrated installer. Servers must be acquired separately. NOTE: This Media pack is optional because the latest ISO image and latest updates may be downloaded at no cost from: http://www.hp.com/go/ic-linux (click on Download button). |
TC208A | |
| NOTE: Electronic software
is available in all countries except China and Japan. For China and Japan
should order the physical equivalent. NOTE: Customer will receive a license entitlement certificate, which must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. NOTE: For additional License Kits, including electronic licensing options, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html |
||
| HP Insight Control server deployment | ||
| HP Insight Control Server Deployment including 1yr 24x7 Support Electronic License | T9082AAE | |
| HP Insight Control Server Deployment including
1yr 24x7 Support Single Server License NOTE: This license allows 1 server to be deployed. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. NOTE: Electronic software is available in all countries except China and Japan. For China and Japan should order the physical equivalent. NOTE: For additional license kits including electronic delivery options, please see the Insight Rapid Deployment software QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_div/12631_div.html |
452151-B21 | |
|
|
||
| High Performance Clusters | HP Cluster Management Utility | |
| HP Cluster Management Utility Flexible License NOTE: This part number can be used to purchase one certificate for multiple licenses with a single activation key. Each license is for one node (server). Customer will receive a printed end user license agreement and license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online in order to obtain a license key. |
QL803A | |
| HP Cluster Management Utility Media NOTE: Order a minimum of one license per cluster to purchase media including software and documentation, which will be delivered to the customer, and also licenses CMU management. No license key is delivered or required NOTE: For additional license kits please see the QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/12612_div/12612_div.html |
433257-B21 | |
| HP HPC Linux Value Pack | ||
| HP High Performance Computing Linux Value
Pack 1 Processor Flexible License NOTE: This part number can be used to purchase one certificate for multiple licenses with a single activation key. Each license is for one socket (a.k.a. processor). Customer will receive a printed end user license agreement and license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online in order to obtain a license key. |
TC293B | |
| HP High Performance Computing Linux Value
Pack Media Kit NOTE: This part number can be used to purchase media including software and documentation, which will be delivered to the customer. NOTE: For additional license kits please see the QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/13485_div/13485_div.html |
TC294A | |
|
|
||
|
HP Security - TPM |
HP Trusted Platform Module Option |
488069-B21
|
| NOTE: The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline. For more information about TPM, including a white paper, go to: www.hp.com/go/TPM. | ||
| NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment. | ||
| NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss. | ||
|
|
||
|
HP I/O Accelerator Options |
HP 160GB Single Level Cell PCIe
ioDrive for ProLiant Servers NOTE: A low-profile PCI bracket is included for use in low-profile slots. |
600278-B21
|
| HP 320GB Multi Level Cell PCIe
ioDrive for ProLiant Servers NOTE: A low-profile PCI bracket is included for use in low-profile slots. |
600279-B21 | |
| HP 320GB Single Level Cell PCIe ioDrive Duo for ProLiant Servers | 600281-B21 | |
| HP 640GB Multi Level Cell PCIe ioDrive Duo for ProLiant Servers | 600282-B21 | |
| HP 1.28TB Multi Level Cell PCIe IO Accelerator | 641027-B21 | |
| NOTE: When the Full length Graphic card is installed in the system, no additional PCIe slots is available and only embedded storage controller is available for up to 4 SATA HDDs configuration. For SAS Hard Disk Drive support for the accelerators, please refer to HP ProLiant DL160se G6 | ||
| NOTE: For more information on the latest visualization and acceleration qualification status, please see: http://www.hp.com/go/accelerators | ||
| NOTE: For minimum
system memory requirements and additional information, please refer to HP
PCIe IO Accelerators for ProLiant Servers QuickSpecs at: http://h18004.www1.hp.com/products/quickspecs/13587_div/13587_div.html (Worldwide) |
||
|
|
||
|
HP Graphics Options |
HP Graphic Card Power Adapter
Kit NOTE: The Graphic Power Adapter Kit can support up to 150 Watts. NOTE: A full-length graphic card cannot fit in the models which have one of the PCIe expansion slots already populated with SAS controller. |
533955-B21
|
|
|
||
| HP Storage Controllers | NOTE: The addition
of storage controllers for internal hard drive use is intended for use ONLY
with the Hot Plug SATA/SAS Model Chassis (P/N 491532-B21). The addition
of a storage controller to the Non-Hot Plug Model Chassis (P/N 491531-B21)
is supported for external storage ONLY. NOTE: To utilize the internal only slot, the HP Smart Array P410 Controller must be selected. The selection of the HP Smart Array P212 Controller for internal and external connectivity, will require the use of the Full Length Full Height PCI-E x16 slot NOTE: With the HP Smart Array P410 Controller, the addition of the battery backed cache upgrade enables BBWC, RAID 5, 5+0, array expansion, logical drive extension, RAID migration, and stripe size migration. In order to upgrade to RAID 6, at least 256MB Cache and a Battery is required in addition to the HP Smart Array Advanced Pack license (P/N 516471-B21). |
|
| SAS Controllers | ||
| Smart Array P212 Controller | ||
| HP Smart Array P212/ZM 1-ports Int/1-ports Ext PCIe x8 SAS Controller |
462828-B21
|
|
| HP Smart Array P212/256 1-ports Int/1-ports Ext PCIe x8 SAS Controller | 462834-B21 | |
| Smart Array P410 Controller | ||
| HP Smart Array P410/256 2-ports Int PCIe x8 SAS Controller |
462862-B21
|
|
| HP Smart Array P410/512 BBWC 2-ports Int PCIe x8 SAS Controller |
462864-B21
|
|
| HP Smart Array P410/1G FBWC 2-ports Int PCIe x8 SAS Controller | 572532-B21 | |
| Smart Array P411 Controller | ||
| HP Smart Array P411/1G FBWC 2-ports Ext PCIe x8 SAS Controller | 572531-B21 | |
| HP Smart Array P411/512 FBWC 2-ports Ext PCIe x8 SAS Controller | 578229-B21 | |
| Smart Array P812 Controller | ||
| HP Smart Array P812/1G FBWC 2-ports Int/4-ports Ext PCIe x8 SAS Controller | 487204-B21 | |
| Storage Controllers for use with External Storage Only | ||
| HP Smart Array P411/256 2-ports Ext PCIe x8 SAS Controller |
462830-B21
|
|
| HP Smart Array P411/512 BBWC 2-ports Ext PCIe x8 SAS Controller |
462832-B21
|
|
| Optional upgrades | ||
| HP 1GB Flash Backed Cache | 534562-B21 | |
| HP 512MB Flash Backed Write Cache | 534916-B21 | |
| HP Non-Hot Plug Internal SAS/SATA
4 Port Cable Kit NOTE: NHP Internal SAS/SATA 4 Port Cable (487734-B21) is required when adding a Smart Array Controller on Non-Hot Plug SATA/SAS server models. |
487734-B21 | |
| HP Smart Array Advanced Pack including 1yr 24x7 Technical Support and Updates Single Server License | 516471-B21 | |
| HP Smart Array Hot Plug Advance Pack for B110i w/1y 24x7 Supp Physical 1 Svr LTU | TC421A | |
| NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Include one year of 24x7 HP Software Technical Support Services. | ||
| SAS HBA | ||
| HP Modular Smart Array SC08e 2-ports
Ext PCIe x8 SAS Host Bus Adapter NOTE: This is a 2 x4 External Port HBA NOTE: This is only approved for the HP Storage Works P2000 G3 SAS Modular Smart Array. NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13651_div/13651_div.html (SC08Ge HBA) |
614988-B21 | |
| NOTE: Please see
the following QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13203_div/13203_div.html (Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_div/13201_div.html (Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_div/13202_div.html (Smart Array P411 Controller) http://h18000.www1.hp.com/products/quickspecs/13558_div/13558_div.html (Smart Array P812 Controller) http://h18000.www1.hp.com/products/quickspecs/13200_div/13200_div.html (Smart Array Advanced Pack) |
||
|
|
||
| HP InfiniBand | QLogic InfiniBand 4X QDR PCI-E G2 Dual Port HCA | 583211-B21 |
| HP InfiniBand 4X DDR PCI-E Dual Port HCA | 448397-B21 | |
| HP InfiniBand 4X QDR ConnectX-2 PCIe G2 Dual Port HCA | 592520-B21 | |
| HP InfiniBand 4X DDR ConnectX-2 PCIe G2 Dual Port HCA | 592521-B21 | |
| HP 10 GbE PCI-e G2 Dual Port Network Interface Card | 516937-B21 | |
| NOTE: For HPC interconnect adapters please see the HPC Interconnect section of this QuickSpecs. |
|
| HP Backup & Recovery Software | Data Protector Express | |
| HP Data Protector Express V5.0 for 1 Server E-LTU | TC330AAE | |
| HP Data Protector Express V5.0 for 3 Servers E-LTU | TC331AAE | |
| HP Data Protector Express V5.0 for 10 Servers E-LTU | TC332AAE | |
| HP Basic Upgrade to Data Protector Express V5 for 1 Server E-LTU | TC333AAE | |
| NOTE: Only one of these Data Protector Express base products is required. To see available options: http://www.hp.com/go/dataprotectorexpress |
|
| HP Tape Backup |
NOTE: For the complete range of tape drives, autoloaders, libraries
and media see: http://www.hp.com/go/tape.
For hardware and software compatibility of HP tape backup products see:
http://www.hp.com/go/connect. |
|
| Tape Drives | ||
| HP DAT 160 SAS Internal Tape Drive NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-Mount Kit (AG576B). No peripheral bay available for installation into the server. |
Q1587A
|
|
| HP DAT 320 SAS Internal Tape Drive NOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-Mount Kit (AG576B). No peripheral bay available for installation into the server. |
AJ830A
|
|
| HP Ultrium 448 SAS Internal Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A). |
DW085A
|
|
| HP Ultrium 920 SAS Internal Tape
Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A). |
EH847A
|
|
| Tape Autoloader | ||
| HP 1/8 G2 Ultrium 920 SAS Autoloader NOTE: Requires HP 1U Tape Autoloader Rack-Mount Kit (AH166A) for rack installation. |
AH558A | |
| Tape Library | ||
| HP MSL2024 Ultrium 920 SAS Tape Library | AH559A | |
| HP MSL2024 1 LTO-5 Ultrium 3000 SAS Tape Library | BL537A | |
|
|
||
|
HP Disk Backup |
NOTE: For the complete range of D2D Backup Systems see: http://www.hp.com/go/d2d. For the complete range of RDX drives and media see: http://www.hp.com/go/rdx. For hardware and software compatibility of HP disk backup products see: http://www.hp.com/go/connect. | |
| HP D2D Backup Systems with Backup Data Deduplication | ||
| HP D2D2502i Backup System NOTE: 1.5TB of usable network disk backup capacity. Network connected appliance with connectivity using the iSCSI protocol. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus Adapter is recommended. |
EJ001B | |
| HP D2D2504i Backup System NOTE: 3.0TB of usable network disk backup capacity. Network connected appliance with connectivity using the iSCSI protocol. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus Adapter is recommended. |
EJ002B | |
| USB Removable Media RDX Disk Backup Systems | ||
| HP RDX1000 Internal Removable Disk Backup System | BV847A | |
| HP RDX320 Internal Removable Disk
Backup System NOTE: For installation into 1U USB Rack-Mount Kit (A8007A). No peripheral bay available for drive installation into the server. 320GB of disk capacity per data cartridge. |
AJ767A | |
| HP RDX500 Internal Removable Disk
Backup System NOTE: For installation into 1U USB Rack-Mount Kit (A8007A). No peripheral bay available for drive installation into the server. 500GB of disk capacity per data cartridge. |
AJ934A | |
|
|
||
| HP Storage Options | Fibre Channel HBA | |
| NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html | ||
| Brocade Fibre Channel HBAs | ||
| HP 81B PCIe 8Gb Fibre Channel Single Port Host Bus Adapter |
AP769A
|
|
| HP 82B PCIe 8Gb Fibre Channel Dual Port Host Bus Adapter |
AP770A
|
|
| HP 41B PCIe 4Gb Fibre Channel Single Port Host Bus Adapter |
AP767A
|
|
| HP 42B PCIe 4Gb Fibre Channel Dual Port Host Bus Adapter |
AP768A
|
|
| Emulex Fibre Channel HBAs | ||
| HP 81E 8Gb Single Port PCI-e Fibre Channel Host Bus Adapter | AJ762A | |
| HP 82E 8Gb Dual Port PCI-e Fibre Channel Host Bus Adapter | AJ763A | |
| HP FC2142SR 4Gb PCIe Host Bus Adapter | A8002A | |
| HP FC2242SR 4Gb PCIe DC Host Bus Adapter | A8003A | |
| QLogic Fibre Channel HBAs | ||
| HP 81Q PCI-e Fibre Channel Host Bus Adapter | AK344A | |
| HP 82Q 8Gb Dual Port PCI-e Fibre Channel Host Bus Adapter | AJ764A | |
| HP FC1142SR 4Gb PCIe Host Bus Adapter | AE311A | |
| HP FC1242SR 4Gb PCIe DC Host Bus Adapter | AE312A | |
| SCSI HBA | ||
| HP U320e SCSI Dual Channel Host
Bus Adapter NOTE: Recommended Dual Channel Ultra320 SCSI Controller for connecting multi-drive MSL tape libraries to ProLiant servers. |
AH627A
|
|
| Converged Network Adapter | ||
| HP CN1000E Dual Port Converged Network Adapter | AW520A | |
| HP CN1000Q Dual Port Converged Network Adapter | BS668A | |
| HP CN1100E Dual Port Converged Network Adapter | BK835A | |
|
|
||
|
HP Disk Storage Systems |
MSA SAN Storage Arrays | |
| HP MSA70 Array | 418800-B21 | |
| NOTE: Supports
up to 12 SFF drives, and SAS 3 Gb/s and SATA 1.5 Gb/s. NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12652_div/12652_div.html |
||
|
|
||
|
HP Uninterruptible Power Systems |
HP Rack-mountable UPS | |
| R5000 Uninterruptible Power System (UPS) | ||
| HP R5KVA 3U IEC309-32A High Voltage INTL Uninterruptible Power System | AF461A | |
| HP R5KVA 3U L630 High Voltage NA/JP Uninterruptible Power System | AF460A | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/14109_div/14109_div.html (Worldwide) | ||
| HP Rack-Mountable R5500 UPS | ||
| HP R5500 6000VA INTL 3U Rackmount Uninterruptible Power System |
AF416A
|
|
| HP R5500 5000kVA NA/JP 3U Rackmount Uninterruptible Power System |
AF426A
|
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/11871_div/11871_div.html (Worldwide) | ||
| R7000 Uninterruptible Power System (UPS) | ||
| HP R7KVA 4U 50A High Voltage NA/JP Uninterruptible Power System | AF462A | |
| HP R7KVA 4U IEC-32A High Voltage INTL Uninterruptible Power System | AF463A | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/14110_div/14110_div.html (Worldwide) | ||
| HP R/T3000 G2 Uninterruptible Power System (UPS) | ||
| HP R/T3000 G2 2U L530 Low Voltage NA/JP Uninterruptible Power System | AF466A | |
| HP R/T3000 G2 2U L620 High Voltage NA/JP Uninterruptible Power System | AF467A | |
| HP R/T3000 G2 2U Detachable Cord High Voltage INTL Uninterruptible Power System | AF468A | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/14058_div/14058_div.html (Worldwide) | ||
| HP R1500 G3 Uninterruptible Power Supply (UPS) | ||
| HP R1.5kVA G3 1U NA Uninterruptible Power System | AF469A | |
| HP R1.5kVA G3 1U JP/TW Uninterruptible Power System | AF470A | |
| HP R1.5kVA G3 1U INTL Uninterruptible Power System | AF471A | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/14059_div/14059_div.html (Worldwide) | ||
| NOTE: For additional
information on HP Uninterruptable Power Systems please go to: www.hp.com/servers/rackups. NOTE: For additional information on sizing your server, please reference: http://www.upssizer.com |
||
| NOTE: Additional HP Uninterruptible Power Systems (UPS) are available for this equipment. For information on all HP UPSs and accessories please go to www.hp.com/products/ups (Worldwide) | ||
| NOTE: Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords. | ||
|
|
||
|
HP Power Distribution Units |
HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 8.6kVA 24A Single Input Three Phase NA/JP Monitored Power Distribution Unit |
AF504A
|
|
| HP 8.3kVA 40A Single Input Single Phase NA/JP Monitored Power Distribution Unit |
AF506A
|
|
| HP 11kVA 16A Single Input Three Phase INTL Monitored Power Distribution Unit |
AF508A
|
|
| HP 7.3kVA 32A Single Input Single Phase INTL Monitored Power Distribution Unit | AF510A | |
| NOTE: Please see
the following QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_div.html (Worldwide) |
||
| HP Monitored Power Distribution Unit: Half Rack Version | ||
| HP 7.3kVA 32A Single Input Single Phase INTL Monitored Power Distribution Unit | AF915A | |
| HP 4.9kVA 24A Single Input Single Phase NA/JP Monitored Power Distribution Unit | AF914A | |
| Modular Power Distribution Units 1U/0U (Up to 32 outlets) | ||
| HP 3.6kVA 16A High Voltage INTL Modular Power Distribution Unit | 252663-B24 | |
| HP 4.9kVA 24A High Voltage NA/JP Modular Power Distribution Unit | 252663-D72 | |
| HP 7.3kVA 32A High Voltage INTL Modular Power Distribution Unit | 252663-B31 | |
| HP 8.3kVA 40A High Voltage NA/JP Modular Power Distribution Unit | 252663-D73 | |
| NOTE: Please see
the following QuickSpecs for additional options including shorter jumper
cables and country specific power cords: http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.html (Worldwide) |
||
| NOTE: Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords. | ||
|
|
||
| HP Intelligent Power Distribution Units (iPDU) | iPDU Core Units | |
| HP 17.3kVA 24A 415V Three Phase L22-30 NA Core Intelligent Power Distribution Unit | AF902A | |
| HP 17.3kVA 24A 415V Three Phase IEC309 NA Core Intelligent Power Distribution Unit |
AF901A
|
|
| HP 4.9kVA 24A Single Phase NA/JP Core Intelligent Modular Power Distribution Unit | AF520A | |
| HP 8.6kVA 24A Three Phase NA/JP Core Intelligent Modular Power Distribution Unit | AF522A | |
| HP 7.3kVA 32A Single Phase INTL Core Intelligent Modular Power Distribution Unit | AF525A | |
| HP 11kVA 16A Three Phase INTL Core Intelligent Modular Power Distribution Unit | AF526A | |
| HP 11.4kVA 16A 415V Three Phase L22-20 NA Core Intelligent Power Distribution Unit | AF900A | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13650_div/13650_div.html (Worldwide) | ||
|
|
||
| HP Rack Series | Rack 10000 G2 Series | |
| HP 10642 G2 1200mm deep Shock Rack | AF092A | |
| HP 10647 G2 1200mm deep Shock Rack |
AF094A
|
|
| HP 10642 G2 Pallet Universal Rack | AF001A | |
| HP 10642 G2 Shock Universal Rack | AF002A | |
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
| HP Rack Options | HP KVM Switches | |
| HP Server Console 0x2x8 Port Analog Switch | AF616A | |
| HP Server Console 0x2x16 Port Analog Switch |
AF617A
|
|
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/11834_div/11834_div.html (Worldwide) |
||
| HP 1x4 USB/PS2 KVM Console Switch | AF611A | |
| Rack 10000 G2 series Cabinets The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment: Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 5,350 sq cm (830 square inches) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation). Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 inches) CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
||
| HP ProLiant DL160 G6 models have fixed rails which provide support for racks with round mounting holes and tool-free support for racks with square mounting holes (including Compaq/HP 7000, 9000, 10000 and HP series), with an adjustment range of 24" - 36" | ||
| NOTE: For additional information regarding Rack Cabinets and Telco Rack support, please see the following URL: www.hp.com/go/rackandpower. | ||
|
|
||
| HP USB and SD Options | HP USB-P/S2 Mouse |
DC369A
|
| HP Keyboard (USB) standard 2004 | DT528A#ABA | |
| HP Internal USB Cable G6 Kit NOTE: In order to connect a USB device internally, the internal USB Cable G6 Kit (536769-B21) must be used. |
536769-B21 | |
|
|
||
| HP Care Pack Services | Hardware Services 4-Hour On-site Service | |
| HP 3 year 4 hour 13x5 ProLiant DL14x and DL16x Hardware Support |
U9509E
|
|
| HP 3 year 4 hour 24x7 ProLiant DL14x and DL16x Hardware Support |
U9510E
|
|
| Hardware Services | ||
| HP 3 year Next business day ProLiant DL14x and DL16x Hardware Support |
U9508E
|
|
| HP Install ProLiant DL14x and DL16x Service | U9520E | |
| NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack |
|
|
Memory
| HP ProLiant DL160 G6 (all models) |
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| Standard Memory 4GB (1x4GB) , 8GB (2 x 4GB) or 24GB(6 x 4GB) depending on model, PC3-10600R-9 Registered RDIMM memory, with ECC. Maximum Memory Up to 288GB memory is available with the optional installation of dual-rank PC3L-10600R 16GB Registered RDIMM memory kits. |
| NOTE: Charts do not represent all possible memory configurations. |
|
DDR3 memory population guidelines
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NOTES:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
DIMM slot and configuration diagrams
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Standard memory configuration (1 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Standard memory plus optional memory (1 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Standard memory replaced with optional memory (1 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
UDIMM maximum configuration (1 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Standard memory replaced with optional memory (2 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
UDIMM maximum configuration (2 CPU model)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NOTE: Capacity references are rounded to the common Gigabyte values.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DDR3 memory
options part number decoder |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Following are memory options available from HP: | ||
| HP Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500656-B21 | |
| HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit | 604504-B21 | |
| HP 4GB (1x4GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500658-B21 | |
| HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 593339-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 Low Power Memory Kit | 604506-B21 | |
| HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit | 500662-B21 | |
| HP 16GB (1x16GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 LP Memory Kit | 627812-B21 | |
| HP 16GB (1x16GB) Quad Rank x4 PC3-8500 (DDR3-1066) Registered CAS-7 Memory Kit | 500666-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB (1x1GB) Single Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500668-B21 | |
| HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500670-B21 | |
| HP 4GB (1x4GB) Dual Rank x8 PC3L-10600 (DDR3-1333) Unbuffered CAS-9 Low Power Memory Kit | 619488-B21 | |
| HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9 Memory Kit | 500672-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: http://www.hp.com/go/proliant-energy-efficient |
||
|
|
Storage
|
|
1-4
|
Four Non-hot plug SATA or four 3.5" Hot-plug SAS/SATA hard drive bays |
| A | Optional DVD-ROM, or DVD RW | |
| 1-8 | Eight Hot-plug SATA/SAS hard drive bays | |
| A | Optional DVD-ROM, or DVD RW |
| Drive Support | |||
|
| |||
|
Quantity |
Position |
Controller | |
|
Removable Media | |||
| DVD-ROM |
Up to 1
|
A
|
Integrated IDE (ATAPI) (optional) |
| DVD RW |
Up to 1
|
A
|
Integrated IDE (ATAPI) (optional) |
| | |||
| Hard Drives NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components. NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details. |
|||
| SATA Hot Plug SFF (2.5-inch) Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 1TB 3G SATA 7.2K 500GB 3G SATA 7.2K |
Up to 8
|
1-8
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SATA Hot Plug LFF (3.5-inch) Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 3TB 3G SATA 7.2K 2TB 3G SATA 7.2K 1TB 3G SATA 7.2K 500GB 3G SATA 7.2K |
Up to 4
|
1-4
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SATA Non-Hot Plug LFF (3.5-inch) Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 3TB 3G SATA 7.2K 2TB 3G SATA 7.2K 1TB 3G SATA 7.2K 500GB 3GSATA 7.2K |
Up to 4
|
1-4
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SATA Hot Plug LFF (3.5-inch) Entry (ETY) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 250GB 3G SATA 7.2K 160GB 3G SATA 7.2K |
Up to 4
|
1-8
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SATA Hot Plug 2.5" Enterprise Mainstream Solid State Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 400GB 3G SATA MLC SSD 200GB 3G SATA MLC SSD 100GB 3G SATA SSD |
Up to 8
|
1-8
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SATA Hot Plug 3.5" Midline (MDL) Solid State Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 400GB 3G SATA MLC SSD 200GB 3G SATA MLC SSD 120GB 3G SATA SSD 100GB 3G SATA SSD |
Up to 4
|
1-4
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SATA Non-Hot Plug LLF ( 3.5-inch) Entry (ETY) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 250GB 3G SATA 7.2K 160GB 3G SATA 7.2K |
Up to 4
|
1-4
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 1TB 6G SAS 7.2K 500GB 6G SAS 7.2K |
Up to 8
|
1-8
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SAS Hot Plug SFF (2.5-inch) Enterprise (ENT) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 900GB 6G SAS 10K 600GB 6G SAS 10K 300GB 6G SAS 15K 300GB 6G SAS 10K 450GB 6G SAS 7.2K 146GB 6G SAS 15K 72GB 6G SAS 15K |
Up to 8
|
1-8
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SAS Hot Plug LFF (3.5-inch) Enterprise (ENT) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 600GB 6G SAS 15K 450GB 6G SAS
15K 300GB 6G SAS 15K |
Up to 4
|
1-4
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SAS Hot Plug SFF (2.5-inch) Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 1TB 6G SAS 7.2K 500GB 6G SAS 7.2K |
Up to 8
|
1-8
|
HP Smart Array P800/512 BBWC Controller
HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SAS Hot Plug LFF (3.5-inch) Midline (MDL) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 3TB 6G SAS 7.2K 2TB 6G SAS 7.2K 1TB 6G SAS 7.2K |
Up to 4
|
1-4
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| SAS Non-Hot Plug (3.5-inch) LFF Enterprise (ENT) Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 600GB 6G SAS 15K 450GB 6G SAS
15K 300GB 6G SAS 15K |
Up to 4
|
1-4
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| 6G SAS Hot Plug Enterprise Performance Solid State Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 400GB 6G SAS SLC SFF SSD 200GB 6G SAS SLC SFF SSD |
Up to 4
|
1-4
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
| 6G SAS Hot Plug Enterprise Mainstream Solid State Drives | |||
|
Quantity
Supported |
Position
Supported |
Controller | |
| 800GB 6G SAS MLC SSD SFF 400GB 6G SAS MLC SSD SFF 200GB 6G SAS MLC SSD SFF |
Up to 4
|
1-4
|
HP Smart Array P212 Controller HP Smart Array P410 Controller HP Smart Array P812/1G Flash Backed Cache Controller |
|
|
|||
|
External Storage |
|||
|
Quantity |
Position |
Host Controller or Adapter |
|
| 70 HP Modular Smart Array | Up to 8 | External | HP Smart Array P212/256MB Controller HP Smart Array P212/256MB Controller HP Smart Array P411/256MB Controller |
|
|
|||
| Tape and Disk Backup | |||
|
NOTE: For the complete range of tape drives, autoloaders, libraries and media, including the internal fitting models, see: http://www.hp.com/go/tape. For the complete range of D2D Backup Systems see: http://www.hp.com/go/d2d. For the complete range of RDX drives and media see: http://www.hp.com/go/rdx. For hardware and software compatibility of HP disk and tape backup products see: http://www.hp.com/go/connect. |
|
Position
Supported |
Controller
|
Controller/HBA Option Kit Part Number
|
|
| HP SCSI Tape Drives LTO-1 Ultrium 232 LTO-2 Ultrium 448 LTO-3 Ultrium 920 LTO-3 Ultrium 960 LTO4 Ultrium 1760 LTO-4 Ultrium 1840 DAT 40 DAT 72 DAT 160 1U Rack-Mount Kit 3U Rack-Mount Kit |
External
|
HP SC11Xe Ultra320 Single Channel/ PCIe x4 SCSI Host Bus Adapter |
412911-B21
|
| HP USB Tape Drives DAT 40 DAT 72 DAT 160 DAT 320 1U USB Rack-Mount Kit |
External
|
USB 2.0 Port |
N/A
|
| HP SAS Tape Drives
DAT 160 DAT 320 LTO-2 Ultrium 448 LTO-3 Ultrium 920 LTO-4 Ultrium 1760 LTO-4 Ultrium 1840 LTO-5 Ultrium 3000 LTO-5 Ultrium 3280 1U Rack-Mount Kit 3U Rack-Mount Kit |
External
|
HP Smart Array P212/ZM 1-ports Int/1-ports Ext PCIe x8 SAS Controller |
462828-B21
|
| HP SCSI Tape Autoloaders DAT 72x10 Autoloader 1/8 G2 Autoloader |
External
|
HP SC11Xe Ultra320 Single Channel/ PCIe x4 SCSI Host Bus Adapter |
412911-B21
|
| HP SCSI Tape Libraries MSL2024 MSL4048 MSL8096 MSL6000 |
External
|
HP U320e SCSI Dual Channel Host Bus Adapter |
AH627A
|
| HP SAS Tape Autoloaders
and Libraries 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 |
External
|
HP Smart Array P212/ZM 1-ports Int/1-ports Ext PCIe x8 SAS Controller |
462828-B21
|
| HP Fibre Channel
Tape Libraries MSL2024 MSL4048 MSL8096 MSL6000 |
External | Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for connectivity information and the supported Fibre Channel HBAs shown in this QuickSpecs. | |
| HP USB RDX Removable
Disk Backup System RDX160 RDX320 RDX500 RDX750 |
External
|
USB 2.0 port |
N/A
|
| HP D2D Backup Systems,
iSCSI D2D2500i D2D4000i |
Rack Mount | Embedded Network Controller. If the server requires a hardware iSCSI initiator, the QLogic QLA4050 Host Bus Adapter is recommended. | |
| HP D2D Backup Systems,
Fibre Channel D2D4000fc |
Rack Mount | Direct server attach is not supported, requires connection via SAN fabric. See: http://www.hp.com/go/connect |
|
|
Power Specifications
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NOTE: |
|
|
System Specifications
|
||||||||||||||||||||||||||||||
| Server Power Cords | One 6' Highline (IEC-IEC) power
cord ships standard NOTE: HP ProLiant DL servers no longer ship standard with NEMA power cords (163719-002) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the NEMA power cord (227099-001) must be ordered separately. If customers require a local power cord, they can check the power cord matrix for the appropriate cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix. |
|
|
Technical Specifications
| System Unit | Dimensions (H x W x D) (with bezel) |
1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm) | ||
| Weight (approximate) |
Maximum (all hard drives, power supplies, and processors installed) |
34.00 lb (16.78 kg) | ||
| Minimum (one hard drive, power supply, and processor installed) |
28.00 lb (12.7 kg) | |||
| Input Requirements (per power supply) |
Rated Line Voltage | 90 to 132 VAC 180 to 264 VAC |
||
| Rated Input Current | 5. 8 Amps (at 100 VAC) to 2.9 Amps (at 200 VAC) | |||
| Rated Input Frequency | 47 to 63 Hz | |||
| BTU Rating | Rated Input Power | 570W (at 100 VAC) 565W (at 200 VAC) |
||
| Maximum | 500W | 1940 BTU / hr (at 100 VAC) 1920 BTU/hr (at 200 VAC) |
||
| 460W | 1773 BTU / hr (at 120 VAC) 1715 (at 240 VAC) |
|||
| 750W | 2892 BTU / hr (at 120 VAC) 2797 (at 240 VAC) |
|||
| Power Specifications | To review typical
system power ratings use the Power Advisor which is available via the online
tool located at URL: www.hp.com/go/proliant-energy-efficient Or www.hp.com/go/hppoweradvisor - Click on the system of interest. Example: DL160 G6 - Follow the instructions of the next screens. |
|||
| Power Supply Output
(per power supply) |
Rated Steady-State Power | 500 Watts (at 100
VAC), 500 Watts (at 200 VAC) |
||
| Maximum Peak Power (See Power Specifications Tables) |
500Watts (at 100 VAC), 500 Watts (at 200 VAC) |
|||
| System Inlet Temperature | Operating | 10° to 35°C
(50° to 95°F) at sea level with an altitude derating of 1.0°C
per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be limited by the type
and number of options installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). |
||
| Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). | |||
| Relative Humidity (non-condensing) |
Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. | ||
| Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). | |||
| Altitude | Operating | 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | ||
| Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | |||
| Acoustic Noise | Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). | |||
| Idle | ||||
|
LWAd
|
6.3B | |||
|
LpAm
|
48dBA | |||
|
Operating
|
||||
|
LWAd
|
6.3B | |||
|
LpAm
|
48dBA | |||
| Emissions Classification (EMC) | FCC Rating | Class A | ||
| Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 | |||
| NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. | ||||
|
|
||||
|
HP 160GB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Entry 1yr Warranty Hard Drive |
458947-B21 | Capacity | 160,041 MB | |
| Height | 1.028 in (2.61 cm) | |||
| Width | 4.0 in (10.16 cm) | |||
| Depth | 5.787 in (147.0 mm) | |||
| Interface | SATA ATA | |||
| Transfer Rate Synchronous (Maximum) |
1.5Gb/s | |||
| Seek Time (typical reads, including settling) | Single Track | 0.9 ms | ||
| Average | 9.0 ms | |||
| Full-Stroke | 17.8 ms | |||
| Rotational Speed | 7,200 rpm | |||
| Physical Configuration | Bytes/Sector | 512 | ||
| Logical Blocks | 312,581,808 | |||
| Operating Temperature | 41° to 131° F (5° to 55° C) | |||
|
|
||||
| NC362i Integrated Dual Port Gigabit Server Adapter | Network Interface | Integrated 10/100/1000BASE-T Transceiver | |
| Combines a triple-speed IEEE 802.3TM - Compliant Media Access Controller (MAC) with a triple-speed Ethernet transceiver. | |||
| Data Transfer Method | Compliant to x1 PCIe Specification | ||
| Controller | Intel® 82576 | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000Mb/s | ||
| Connector | RJ-45 connector | ||
| Cable Support | Performs all the physical layer functions for 10BASE-T, 100BASE-T, and 1000BASE-T Ethemet on standard Category 5 UTP | ||
|
|
|||
|
Smart Array P410/410i Controller |
Disk Drive and Enclosure Interface | 6Gb/s SAS (Serial Attached SCSI) |
| 3Gb/s SATA (Serial ATA) | ||
| SAS Connectors | 2 internal (Mini-SAS) x8 wide port connectors | |
| Cache Memory Speed | DDR2-533MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth. | |
| Server Interface | x8 2.5G PCIe 2.0 provides 2GB/s maximum bandwidth | |
| SAS Speed | x8 6Gb/s SAS provides 4.8GB/s maximum bandwidth | |
| Cache Memory | 40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade | |
| Logical Drives Supported | Up to 64 logical drives | |
| Host Memory Addressing | 64-bit, supporting greater than 4GB server memory space | |
| RAID Support | RAID 6, 6+0 (Advanced Data Guarding) NOTE: The minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade is required to enable RAID 6, 6+0 |
|
| RAID 5, 5+0 (Distributed Data
Guarding) NOTE: The 256 MB is required to enable RAID 5, 5+0 support of the Smart Array P410 |
||
| RAID 1+0 (Striping & Mirroring) | ||
| RAID 0 (Striping) | ||
|
|
||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner. |
| | ||
|
© Copyright 2012 Hewlett-Packard Development Company,
L.P. |